PKU (Phenylketonuria) Serum HPLC Analysis Kit User Manual

Similar documents
PKU (Phenylketonuria) Serum LC-MS/MS Analysis Kit User Manual

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual

Vitamin A-E Serum HPLC Analysis Kit

25-Hydroxyvitamin D2-D3 Serum VD-200 UHPLC Analysis Kit User Manual

25-Hydroxyvitamin D2-D3 Serum LC-MS/MS APCI Analysis Kit User Manual

FinTest IgG4 Screen 20 ELISA KIT

Iodine HPLC Assay. Catalog Number: IOD34-H Tests For Research Use Only. Not for use in diagnostic procedures.

retardation in infants. A wide variety of analytical methods for the analysis of

Mouse C-Peptide ELISA Kit

Instructions for use. TSH rat ELISA. Please use only the valid version of the Instructions for Use provided with the kit AR E-8600

FinTest TM IgG4 Screen 88 ELISA Kit

Mouse C-peptide ELISA

Porcine/Canine Insulin ELISA

Influenza A IgG ELISA

Mouse C-peptide ELISA

Rat Insulin ELISA. For the quantitative determination of insulin in rat serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Vedolizumab Drug Level ELISA

Bovine Insulin ELISA

Morinaga Mouse C-peptide ELISA Kit

RayBio Phenylalanine Fluorometric Assay Kit

IV2-113E Use by. Invitron Glargine ELISA Kit REF LOT IVD. Definitions. English. For in-vitro diagnostic use. Instructions for use.

Mouse Ultrasensitive Insulin ELISA

Insulin (Porcine/Canine) ELISA

Rat Hemoglobin A1c (HbA1c) Kit Instructions

Rat C-peptide ELISA. For the quantitative determination of C-peptide in rat serum

Rat Proinsulin ELISA

MALDI Sepsityper Kit

Rat C-peptide ELISA. For the quantitative determination of C-peptide in rat serum. For Research Use Only. Not For Use In Diagnostic Procedures.

Procine sphingomyelin ELISA Kit

Chymotrypsin ELISA Kit

VITAMINES A / E IN PLASMA BY UV - FAST CODE Z18610

Product # Kit Components

ab HIV-1 Protease Inhibitor Screening Kit (Fluorometric)

Insulin ELISA. For the quantitative determination of insulin in serum and plasma

Myeloperoxidase (MPO) ELISA Stool, Urine KIT

Organic Acid Urine LC-MS/MS Analysis Kit

ab HRV 3C Protease Inhibitor Screening Kit (Colorimetric)

Instructions for Use. IA2 Antibody ELISA. Enzyme Immuno Assay for the Quantitative Determination of Antibodies against IA-2 in Serum.

PLATELIA CANDIDA Ab PLUS Negative and Positive Controls. Quality Control Human Sera

Serum Amyloid A ELISA

Blood Urea Nitrogen Enzymatic Kit Manual Catalog #:

VGKC-Autoantibody Assay RIA

Human HIV (1+2) antigen&antibody ELISA Kit

25(OH) Vitamin D ELISA (BD-220BA), 192 Tests

Apolipoprotein A-1 ELISA

Blood Urea Nitrogen Enzymatic Kit Manual Catalog #:

Amal Alamri. Phenylketonuria

Manual. Transfer step. Figure 1. Workflow comparison of manual phenylalanine assay and automated GSP Neonatal Phenylalanine assay

ab Creatinine Assay Kit (Colorimetric)

Canine Thyroid Stimulating Hormone, TSH ELISA Kit

Insulin ELISA. For the quantitative determination of insulin in serum and plasma.

Rat IL-2 ELISA Kit. Instructions for use. For research use only. Fast Track Your Research.

Mouse C3 (Complement Factor 3) ELISA Kit

Cotinine (Mouse/Rat) ELISA Kit

Human Thyroid-Peroxidase Antibody, TPO-Ab ELISA Kit

Instructions for use. TSH rat ELISA. Please use only the valid version of the Instructions for Use provided with the kit AR E-8600

Human Thyroglobulin EIA

Norgen s HIV proviral DNA PCR Kit was developed and validated to be used with the following PCR instruments: Qiagen Rotor-Gene Q BioRad icycler

Kit Components Product # EP42720 (24 preps) MDx 2X PCR Master Mix 350 µl Cryptococcus neoformans Primer Mix 70 µl Cryptococcus neoformans Positive

02006B 1 vial 02006B 1 vial Store at -20 C. Lyophilized recombinant IL-2

Rubella virus IgG ELISA Kit

RealLine HIV quantitative Str-Format

HbA1c (Human) ELISA Kit

HBeAg and HBeAg Ab ELISA Kit

PRINCIPLE OF THE TEST

Insulin Rodent (Mouse/Rat) Chemiluminescence ELISA

Mouse GLP-2 EIA. Cat. No. KT-374. For the quantitative determination of GLP-2 in mouse serum or plasma. For Research Use Only. 1 Rev.

ab Tryptophan Assay Kit (Fluorometric)

EASI-EXTRACT BIOTIN Product Code: P82 / P82B

Triiodothyronine (T3) ELISA

STELLUX C-peptide Chemiluminescence ELISA

Mouse Leptin ELISA Kit Instructions

AMIODARONE and DESETHYLAMIODARONE IN PLASMA BY UV FAST CODE Z33610

Human Cytomegalovirus IgM ELISA Kit

CYTOMEGALOVIRUS (CMV) IgM ELISA Kit Protocol

Norgen s HIV Proviral DNA PCR Kit was developed and validated to be used with the following PCR instruments: Qiagen Rotor-Gene Q BioRad T1000 Cycler

EASI-EXTRACT FOLIC ACID Product Code: P81 / P81B

ab HMG-CoA Reductase Activity Assay Kit (Colorimetric)

RealLine HBV / HCV / HIV Str-Format

Cytomegalovirus (CMV) End-Point PCR Kit Product# EP36300

Human Cytomegalovirus Virus (CMV) IgG ELISA Kit

This kit is intended for Research Use Only. Not for use in diagnostic procedures.

Mouse/Rat THYROXINE (T4) ELISA Catalog No (96 Tests)

Exendin-4 (Exenatide) ELISA Kit

ab TSH Receptor Autoantibody ELISA Kit

DRG International, Inc., USA Fax: (908)

EASIMIP TM PATULIN Product Code: P250 / P250B

TSH Receptor Autoantibody ELISA

ab65344 Uric Acid Assay Kit (Colorimetric/Fluorometric)

DIAGNOSTIC AUTOMATION, INC.

Instructions for Use. IA-2 Antibody RIA. for the Quantitative Determination of Antibodies against Protein-Tyrosine-Phosphatase (IA2) in Serum

Human Thyroid Stimulating Hormone CLIA kit

Ultra-sensitive Human TSH ELISA Kit. MyBioSource.com

HIV-1 p24 ELISA Kit. Catalog Number KA assays Version: 06. Intended for research use only.

Nitrate/Nitrite Assay Kit Manual Catalog #

ab HRV 3C Protease Activity Assay Kit (Colorimetric)

Transcription:

Page 1 / 20 PKU (Phenylketonuria) Serum HPLC Analysis Kit User Manual ZV-4003-0200-10 200 2-8 C

Page 2 / 20 Table of Contents 1. INTENDED USE... 3 2. SUMMARY AND EXPLANATION... 3 3. TEST PRINCIPLE... 3 4. WARNING AND PRECAUTIONS... 3 5. STORAGE AND STABILITY... 4 6. MATERIALS SUPPLIED... 4 7. MATERIALS REQUIRED BUT NOT SUPPLIED... 5 8. PROCEDURE NOTES... 5 9. LIMITATIONS OF THE PROCEDURE... 6 10. PRE-SET UP INSTRUCTIONS... 6 11. TEST PROCEDURE... 7 12. QUALITY CONTROL... 7 13. CALCULATION OF RESULTS... 8 14. INTERPRETATION OF RESULTS... 8 15. EXPECTED VALUES... 9 16. HPLC-UV PARAMETERS... 9 17. ANALYTICAL PERFORMANCE... 9 18. SAMPLE CHROMATOGRAM... 10

Page 3 / 20 1. INTENDED USE HPLC-UV analysis kit for quantitative determination of phenylketonuria in human serum & plasma samples. 2. SUMMARY AND EXPLANATION Phenylketonuria (PKU) is an autosomal recessive genetic disorder characterized by a deficiency in the enzyme phenylalanine hydroxylase (PAH). This enzyme is necessary to metabolise the amino acid phenylalanine to the amino acid tyrosine. When PAH is deficient, phenylalanine accumulates on the brain tissue and is converted into phenyl pyruvate (also known as phenyl ketone), which is detected in the urine. PAH is found on chromosome number 12. If left untreated, this condition can cause problems with brain development, leading to progressive mental retardation and seizures. However, PKU can be controlled by a special diet with low in phenylalanine and high in tyrosine can be a very effective treatment. There is no cure. The disorder is only detectable after irreversible damage is done hence early diagnosis is crucial. Most babies in developed countries are screened for PKU soon after birth. PKU is usually detected using the HPLC test, but some clinics still use the Guthrie test, as a part of national biochemical screening programs. Zivak PKU HPLC-UV Analysis Kit was developed for sensitive, rapid and accurate quantitative detection of Phenylketonuria in human serum & plasma samples gives results in 9 minutes with minimal sample preparation. Main methods and procedures that have been selected are based on EN ISO 13485 and 98/79/EC. 3. TEST PRINCIPLE Phenylalanine, tyrosine and tryptophan are eluted from human samples using an acidic extraction and deproteinization step. Extracted analytes are analyzed by HPLC-UV system. 4. WARNING AND PRECAUTIONS For in-vitro diagnostic use only. For professional use only. Read the instructions carefully, before you start.

In case of damage of the kit package, please contact Zivak or your supplier. Do not use expired kits and components. Please check the batch no and expiry date before start. Protective gloves and goggles should be worn. Please take any necessary precautions to prevent infection with blood borne pathogens while working with biological fluids. Appropriate bio-safety precautions and disposal of bio-hazardous wastes should be followed. Please check the labels on reagent bottles. Reagents of this kit contain hazardous material may cause eye and skin irritations. Page 4 / 20 5. STORAGE AND STABILITY The kit can be shipped at room temperature. After arrival, calibrator and controls, R1 can be stored at 2-8 C. MP, WB can be stored at room temp. All components are guaranteed until expiry date when stored at recommended temperatures and used as described in these instructions. 6. MATERIALS SUPPLIED Order No. Volume Symbol Component ZV-4003-02R1-10 1 x 150 ml R1 Reagent 1, Contains internal standard ZV-4003-02MP-10 2 x 2 L MP Mobile Phase, Contains organic solvent ZV-4003-02WB-10 1 x 0,5 L WB Washing solution, Contains organic solvent KK ZV-4003-KK-10 1 pc User Guide

Page 5 / 20 7. MATERIALS REQUIRED BUT NOT SUPPLIED Order No. Volume Symbol Component ZV-4003-02S1-10 1 x 3 ml Calibrator Level 1 Dried Blood Spot Calibrator Level 1 Control ZV-4003-02K1-10 1 x 3 ml Dried Blood Spot Control Level 1 Level 1 Control ZV-4003-02K2-10 1 x 3 ml Level 2 Dried Blood Spot Control Level 2 ZV-4003-02C1-10 1 pcs Zivak PKU Serum HPLC Analytical Column 20-200 µl pipette 200-1000 µl pipette Pipette tips Vortex mixer Capped preparation tubes Centrifuge Bidistilled or deionised water 1.8 ml conical autosampler vial or vial insert 8. PROCEDURE NOTES Any inappropriate handling of samples or modification of the test procedure may influence the results. The indicated pipetting volumes, incubation times, temperatures and pre-treatment steps have to be performed strictly according to the instructions. Use calibrated pipettes and devices only. Once the test has been started, all steps should be completed without interruption. Make sure that required reagents, materials and devices are prepared ready at the appropriate time. Leave aside all reagents and specimens to reach room temperature (18-25 C) and gently swirl each vial of liquid reagent and sample before use. Mix reagents without foaming. Avoid contamination of reagents, pipettes and wells/tubes. Use new disposable plastic pipette tips for each reagent, standard or specimen. Do not interchange the vial caps. Always keep vials closed when not been used. Do not re-use wells/tubes or reagents.

Incubation time affects results. All tubes or wells should be handled in the same order and time sequences. Page 6 / 20 9. LIMITATIONS OF THE PROCEDURE Specimen collection has a significant effect on the test results. Any result with an elevated concentration has to be indicated as presumptive positive and has to be confirmed with further sampling and testing. A false negative result of this assay cannot be excluded with absolute certainty. Any anamnestic or clinical hint of phenylketonuria has to lead to a repeated measurement. A direct influence of applied drugs to the patients on the phenylalanine results cannot be excluded. Therefore, it is highly recommended to review in these cases even a normal phenylalanine value with a confirmation test if there are anamnestic or clinical signs of a phenylketonuria in a patient. 10. PRE-SET UP INSTRUCTIONS Set-up the Instrument: Purge the HPLC pumps with high flow rate of mobile phase(s). This should be done by pumping the mobile phase(s) through the system for 15 minutes at a flow rate of 4.0ml/min. Switch off the pump and connect the column in flow direction. Activate the method and allow mobile phase(s) to flow through the column. In order to receive stable base line conditions, we recommend to continue circulating the mobile phase(s) for further 30 minutes prior to injecting the first sample. Make sure the bottle of mobile phase bottle is closed well, otherwise components of the mobile phase(s) could evaporate; this alters the retention times. Preparation of Calibrators: Add 3 ml of deionised water to plasma calibrator and dissolve. After preparation, calibrator must be aliquoted into 75 µl volumes and stored at -20 C. Preparation of Control Level I: Add 3 ml of deionised water to Plasma control level I and dissolve. After preparation, control level I must be aliquoted into 75 µl volumes and stored at -20 C.

Page 7 / 20 Preparation of Control Level II: Add 3 ml of deionised water to Plasma control Level II and dissolve. After preparation, control level II must be aliquoted into 75 µl volumes and stored at -20 C. 11. TEST PROCEDURE Sample Pre-treatment (Manual) Take 50 L of plasma calibrator into a 2 ml preparation tube. Add 300 L of R1. Mix by vortex for 5 seconds and incubate for 15 minutes at 4 C. Centrifuge at 5.000 x rpm for 1 minute. Take 200 µl upper liquid into autosampler vial. Inject 20 L to the HPLC-UV system. Note: The prepared sample is stable at 2-8 C for 24 hours. 12. QUALITY CONTROL The test results are only valid if the test has been performed by following the instructions. Moreover the user must strictly adhere to the rules of GLP (Good Laboratory Practice) or other applicable standards/laws. All standards and kit controls must be found within the acceptable ranges as

stated on the QC (Quality Control) Certificate. If the criteria are not met, the run is not valid and should be repeated. Each laboratory should use known samples as further controls. In case of any deviation, the following technical issues should be proven: Expiry dates of (prepared) reagents, storage conditions, pipettes, devices, incubation conditions and washing methods. It is recommended to participate at appropriate quality assessment trials. Page 8 / 20 13. CALCULATION OF RESULTS The obtained area of the standard is plotted against their concentration. The standard curve is calculated by a linear regression or a weighted linear regression function. Using computer programs, the curve is best described by a 1-point linear regression fit with linear axes. For the calculation of the regression curve, apply each signal of the standards. (One obvious outlier of duplicates might be omitted and the more plausible single value might be used) The concentration of the samples can be read directly from the regression function. Sample signals above the highest control have to be confirmed by a reference method. *IS: Internal Standard 14. INTERPRETATION OF RESULTS Various societies recommend different Cut-Off values for repetition of the measurement and the application of confirmatory assays. Depending on the application of patient samples from different populations, it is highly recommended that each laboratory establishes its own range of normal values and that this distribution of values is coordinated with the recommendations of the responsible society of this geographic region. The results themselves should not be the only reason for any therapeutic consequences. They have to be correlated to other clinical observations and diagnostic tests.

Page 9 / 20 15. EXPECTED VALUES Phe/Tyr molar ratio must be 2.5 to confirm the diagnosis of hyperphenylalaninemia. It is recommended that each laboratory establishes its own range of normal values. 16. HPLC-UV PARAMETERS Device Column Zivak ASP-100 HPLC-UV/VIS System Zivak PKU Serum HPLC Analytical Column Injection Volume 20 µl Pump Program Flow Column Oven 30 C 00:00 min 100% A 09:00 min 100% A 0.50 ml/min Detector Wavelength UV 214 nm 17. ANALYTICAL PERFORMANCE No Analyte LOD (µmol/ L) LOQ (µmol/ L) Accuracy (%) Intra-Assay Precision (%CV) Inter-Assay Precision (%CV) Linearity (R 2 ) 1 Phenylalanine (PHE) 0.35 1.05 97 3.9 4.2 0.997 2 Tryptophan (TRP) 0.60 1.80 98 3.4 3.8 0.996 3 Tyrosine (TYR) 0.85 2.55 97 4.9 5.3 0.998 Analytical Specificity (Cross Reactivity): No cross-reactivity was found with the typical substances tested.

Page 10 / 20 18. SAMPLE CHROMATOGRAM

Page 11 / 20 PKU (Phenylketonuria) Dried Blood Spots HPLC Analysis Kit User Manual ZV-4003-0200-15 200 2-8 C

Page 12 / 20 Table of Contents 1. INTENDED USE... 13 2. SUMMARY AND EXPLANATION... 13 3. TEST PRINCIPLE... 13 4. WARNING AND PRECAUTIONS... 13 5. STORAGE AND STABILITY... 14 6. MATERIALS SUPPLIED... 14 7. MATERIALS REQUIRED BUT NOT SUPPLIED... 15 8. PROCEDURE NOTES... 15 9. LIMITATIONS OF THE PROCEDURE... 16 10. PRE-SET UP INSTRUCTIONS... 17 11. TEST PROCEDURE... 17 12. QUALITY CONTROL... 17 13. CALCULATION OF RESULTS... 18 14. INTERPRETATION OF RESULTS... 18 15. EXPECTED VALUES... 19 16. HPLC-UV PARAMETERS... 19 17. ANALYTICAL PERFORMANCE... 19 18. SAMPLE CHROMATOGRAM... 20

Page 13 / 20 1. INTENDED USE HPLC-UV analysis kit quantitative determination of phenylketonuria in human dried blood samples. 2. SUMMARY AND EXPLANATION Phenylketonuria (PKU) is an autosomal recessive genetic disorder characterized by a deficiency in the enzyme phenylalanine hydroxylase (PAH). This enzyme is necessary to metabolise the amino acid phenylalanine to the amino acid tyrosine. When PAH is deficient, phenylalanine accumulates on the brain tissue and is converted into phenyl pyruvate (also known as phenyl ketone), which is detected in the urine. PAH is found on chromosome number 12. If left untreated, this condition can cause problems with brain development, leading to progressive mental retardation and seizures. However, PKU can be controlled by a special diet with low in phenylalanine and high in tyrosine can be a very effective treatment. There is no cure. The disorder is only detectable after irreversible damage is done hence early diagnosis is crucial. Most babies in developed countries are screened for PKU soon after birth. PKU is usually detected using the HPLC test, but some clinics still use the Guthrie test, as a part of national biochemical screening programs. Zivak PKU HPLC-UV Analysis Kit was developed for sensitive, rapid and accurate quantitative detection of Phenylketonuria in human dried blood spot samples gives results in 9 minutes with minimal sample preparation. Main methods and procedures that have been selected are based on EN ISO 13485 and 98/79/EC. 3. TEST PRINCIPLE Phenylalanine, tyrosine and tryptophan are extracted from human dried blood spot samples using an acidic extraction step and analyzed by HPLC-UV system. 4. WARNING AND PRECAUTIONS For in-vitro diagnostic use only. For professional use only. Read the instructions carefully, before you start. In case of damage of the kit package, please contact Zivak or your supplier. Do not use expired kits and components.

Please check the batch no and expiry date before start. Protective gloves and goggles should be worn. Please take any necessary precautions to prevent infection with blood borne pathogens while working with biological fluids. Appropriate bio-safety precautions and disposal of bio-hazardous wastes should be followed. Please check the labels on reagent bottles. Reagents of this kit contain hazardous material may cause eye and skin irritations. All calibrators and controls of this kit which contain human blood or dried blood was tested and found negative for HIV 1/2 and HCV antibodies, HbsAg, HIV 1/2 and HCV genome. Nevertheless, the blood controls should be considered as potentially infectious and treated with appropriate care. 5. STORAGE AND STABILITY Page 14 / 20 The kit can be shipped at room temperature. After arrival, calibrator and controls, R1 can be stored at 2-8 C. MP, WB can be stored at room temp. All components are guaranteed until expiry date when stored at recommended temperatures and used as described in these instructions. 6. MATERIALS SUPPLIED Order No. Volume Symbol Component ZV-4003-05R1-15 1 x 150 ml R1 Reagent 1, Contains internal standard ZV-4003-05MP-15 2 x 2 L MP Mobile Phase, Contains organic solvent ZV-4003-05WB-15 1 x 0,5 L WB Washing solution, Contains organic solvent ZV-4003-KK-Eng-15 1 pc KK User Guide

Page 15 / 20 7. MATERIALS REQUIRED BUT NOT SUPPLIED Order No. Volume Symbol Component ZV-4003-02S1-15 1 x 1 Spot Calibrator Level 1 Dried Blood Spot Calibrator Level 1 Control ZV-4003-02K1-15 1 x 1 Spot Dried Blood Spot Control Level 1 Level 1 Control ZV-4003-02K2-15 1 x 1 Spot Dried Blood Spot Control Level 2 Level 2 ZV-4003-02C1-15 1 pcs Zivak PKU Dried Blood Spots HPLC Analytical Column 3.5 mm puncher 20-200 µl pipette 200-1000 µl pipette Pipette tips Vortex mixer Capped preparation tubes Conical autosampler vial or vial insert User manual 8. PROCEDURE NOTES Any inappropriate handling of samples or modification of the test procedure may influence the results. The indicated pipetting volumes, incubation times, temperatures and pre-treatment steps have to be performed strictly according to the instructions. Use calibrated pipettes and devices only. Once the test has been started, all steps should be completed without interruption. Make sure that required reagents, materials and devices are prepared ready at the appropriate time. Leave aside all reagents and specimens to reach room temperature (18-25 C) and gently swirl each vial of liquid reagent and sample before use. Mix reagents without foaming. Avoid contamination of reagents, pipettes and wells/tubes. Use new disposable plastic pipette tips for each reagent, standard or specimen. Do not interchange the vial caps. Always keep vials closed when not been used. Do not re-use wells/tubes or reagents.

Incubation time affects results. All tubes or wells should be handled in the same order and time sequences. Page 16 / 20 9. LIMITATIONS OF THE PROCEDURE Specimen collection has a significant effect on the test results. Please always follow the universal safety precautions for accurate and safe DBS sampling given below. Universal Safety Precautions for DBS sampling: Treat all blood samples as though they are infectious Wash hands, wear gloves and apron/lab coats Take precaution to avoid needle injury Dispose of contaminated sharps and waste appropriately Clearly label each card with appropriate identification number. It is unacceptable to submit a blood card for testing that has not been properly labelled. Apply gentle pressure to the heel and allow a large drop of free flowing blood to collect at the puncture site. Working quickly, hold the filter paper by the edges and touch the filter paper gently against the large drop of blood and in one step allow a sufficient quantity of blood to soak through and completely fill or saturate a circle. A completed saturated spot will contain approx.100 µl of blood. Repeat, until you have collected enough blood to fill at least 3 circles on the blood collection card. It is critical that entire circle be uniformly saturated with blood. If collecting spots using a pipette, collect 100 µl of blood and gently apply to filter paper. Any result with an elevated concentration has to be indicated as presumptive positive and has to be confirmed with further sampling and testing. A false negative result of this assay cannot be excluded with absolute certainty. Any anamnestic or clinical hint of phenylketonuria has to lead to a repeated measurement. A direct influence of applied drugs to the patients on the phenylalanine results cannot be excluded. Therefore, it is highly recommended to review in these cases even a normal phenylalanine value with a confirmation test if there are anamnestic or clinical signs of a phenylketonuria in a patient.

Page 17 / 20 10. PRE-SET UP INSTRUCTIONS Set-up the Instrument: Purge the HPLC pumps with high flow rate of mobile phase(s). This should be done by pumping the mobile phase(s) through the system for 15 minutes at a flow rate of 4.0ml/min. Switch off the pump and connect the column in flow direction. Activate the method and allow mobile phase(s) to flow through the column. In order to receive stable base line conditions, it s recommended to continue circulating the mobile phase(s) for further 30 minutes prior to injecting the first sample. Make sure the bottle of mobile phase bottle is closed well, otherwise components of the mobile phase(s) could evaporate; this alters the retention times. 11. TEST PROCEDURE Sample Pre-treatment (Manual) Take dried blood spot sample in 3.5 mm diameter by a puncher into a 2 ml preparation tube. Add 300 L of R1 to each sample. Mix by vortex for 5 secs. Incubate for 30 minutes at 37 C. Centrifuge at 12.000 x rpm for 1 minute. Take 200 µl of upper liquid into autosampler vial. Inject 20 L to the HPLC-UV system. Note: The prepared sample is stable at 2-8 C for 24 hours. 12. QUALITY CONTROL The test results are only valid if the test has been performed by following the instructions. Moreover the user must strictly adhere to the rules of GLP (Good Laboratory Practice) or other applicable standards/laws. All standards and kit controls must be found within the acceptable ranges as

stated on the QC (Quality Control) Certificate. If the criteria are not met, the run is not valid and should be repeated. Each laboratory should use known samples as further controls. In case of any deviation, the following technical issues should be proven: Page 18 / 20 Expiry dates of (prepared) reagents, storage conditions, pipettes, devices, incubation conditions and washing methods. It is recommended to participate at appropriate quality assessment trials. 13. CALCULATION OF RESULTS The obtained area of the standard is plotted against their concentration. The standard curve is calculated by a linear regression or a weighted linear regression function. Using computer programs, the curve is best described by a 1-point linear regression fit with linear axes. For the calculation of the regression curve, apply each signal of the standards. (One obvious outlier of duplicates might be omitted and the more plausible single value might be used) The concentration of the samples can be read directly from the regression function. Sample signals above the highest control have to be confirmed by a reference method. *IS: Internal Standard 14. INTERPRETATION OF RESULTS Various societies for neonatal screening recommend different Cut-Off values for repetition of the measurement and the application of confirmatory assays. Depending on the application of samples of different populations of new-borns, it is highly recommended that each laboratory establishes its own range of normal values and that this distribution of values is co-ordinated with the recommendations of the responsible society of this geographic region. The results themselves should not be the only reason for any therapeutic consequences. They have to be correlated to other clinical observations and diagnostic tests.

Page 19 / 20 15. EXPECTED VALUES Phe/Tyr molar ratio must be 2.5 to confirm the diagnosis of hyperphenylalaninemia. It is recommended that each laboratory establishes its own range of normal values. 16. HPLC-UV PARAMETERS Device Column Zivak ASP-100 HPLC-UV/VIS System Zivak PKU Dried Blood Spots HPLC Analytical Column Injection Volume 20 µl Pump Program Flow Column Oven 30 C 00:00 min 100% A 13:00 min 100% A 0.50 ml/min Detector Wavelength UV 214 nm 17. ANALYTICAL PERFORMANCE No Analyte LOD (µmol/ L) LOQ (µmol/ L) Accuracy (%) Intra-Assay Precision (%CV) Inter-Assay Precision (%CV) Linearity (R 2 ) 1 Phenylalanine (PHE) 0.35 1.05 98,4 1.4 3.2 0.997 2 Tryptophan (TRP) 0.20 0.60 97,1 1.3 3.1 0.996 3 Tyrosine (TYR) 0.45 1.35 99,5 1.4 3.2 0.998 Analytical Specificity (Cross Reactivity): No cross-reactivity was found with the typical substances tested.

Page 20 / 20 18. SAMPLE CHROMATOGRAM