QUALITY CONTROL IN CLINICAL

Similar documents
1/24/2011. QUALITY CONTROL IN CLINICAL STUDIES Tuesday, January 25, Outline

Data Collection Worksheet

2. Measure a subject's blood pressure and heart rate both at rest and during exercise.

Home Blood Pressure Log

Lecture #3 - Blood Pressure Recording Procedure. Equipment

Chapter 7 BAYLEY SCALES OF INFANT DEVELOPMENT

Section 03: Pre Exercise Evaluations and Risk Factor Assessment

Chapter-III METHODOLOGY. In this chapter, the procedure adopted for the selection of the

Importance Of Taking Manual Blood Pressure In Both Arms

CLINICAL EVIDENCE MADE EASY

LABORATORY SAFETY SERIES: Laboratory Ergonomics

Documentation, Codebook, and Frequencies

UK Biobank. Arterial Pulse-Wave Velocity. Version th April 2011

Blood Pressure Competency Training

AMERICAN ASSOCIATION OF SLEEP TECHNOLOGISTS TECHNICAL GUIDELINE FOR PATIENT ASSESSMENT AND VITAL SIGNS MEASUREMENT AND DOCUMENTATION

UK Biobank. 12-lead (at rest) ECG. Version Oct 2015

Managing Blood Pressure: It Takes a Team

Documentation, Codebook, and Frequencies

Audiology Assessment. 0c. Exam type:

Ambulatory Services Orientation & Skill Review Skill Performance Checklist: Vital Signs. Name: Date:

OVERVIEW OF 30-MONTH FOLLOW-UP

MOST Operations Manual page 1 OVERVIEW OF 60-MONTH FOLLOW-UP VISIT

Taking and recording blood pressure and pulse. City Gate Training Centre all rights reserved

9/27/2016. Adherence and Monitoring of Hypertensive Patients. Conflicts of Interest. Brought to you though a partnership:

Agenda and Objectives

Heart Rate, Blood Pressure, and Exercise. Evaluation copy

UK Biobank. Hearing Speech-in-Noise Test. Version August 2012

How to select an age-friendly fitness facility

Welcome! ACE Personal Trainer Virtual Exam Review: Module 5. Laura Abbott, MS, LMT. What We ll Cover This Module

Equipment for Quality Care

TRAINING COORDINATOR TRAINING

Table of Contents. Summary of Tupler Technique Program How the Program Works Checking for Diastasis Splinting Tips...

CONCORD INTERNAL MEDICINE HYPERTENSION PROTOCOL

Physical Therapist Assistant Patient Interventions

Entered: / / 20 Initials: Verified: / / 20 Initials: For office use only.

Quality Assurance Mapping Your QC Program Equipment and Test Quality. Susan Blonshine RRT, RPFT, FAARC, AE-C

SECTION 16: BLOOD PRESSURE MEASUREMENT

CHAPTER 2 EVALUATING NUTRITION INFORMATION OVERVIEW

Parkland Health & Hospital System Women & Infant Specialty Health

AFFORDABLE TECHNOLOGY

Chapter 29 1/8/2018. Vital Signs. Measuring and Reporting Vital Signs. Key Terms

How to select an age-friendly fitness facility

10425 N. Central Expressway Dallas, TX o f

renew You can t predict if you will get lower your cancer risk Learn about screenings for colon cancer. See Page 5. Fall

Validity and reliability of measurements

Overview of the FITNESSGRAM Body Composition Standards

Hands on Sports Therapy KNOWLEDGE REVIEW QUESTIONS 2004 Thomson Learning It can help to shape a basic fitness training programme

BLOOD PRESSURE ASSESSMENT

OVERVIEW OF 15-MONTH FOLLOW-UP

Vital Signs. 1. Define important words in this chapter. 2. Discuss the relationship of vital signs to health and well-being

PREEHCO PROJECT ANTHROPOMETRIC AND MOBILITY TESTING PROCEDURES

UK Biobank. Grip Strength Measurement. Version th April 2011

SARASOTA MEMORIAL HOSPITAL NURSING PROCEDURE. MEASURING BLOOD PRESSURE - MANUAL (equ04)

Workstation Ergonomics Self Assessment

2

Chapter 08. Health Screening and Risk Classification

"LABORATORY ERGONOMICS"

Biases in clinical research. Seungho Ryu, MD, PhD Kanguk Samsung Hospital, Sungkyunkwan University

SMALL GROUP SESSION 8 October 21st or October 23 rd. Narratives Discussion/ OSCE Practice

Environmental Health & Safety

Sonography Program Application and Information Packet. Lackawanna College Sonography Programs Technical Standards

Northwestern University. Consent Form and HIPAA Authorization for Research

PLANK 1 Direct Care Staff Trained in Accurate BP Measurement

ADDRESSING CHRONIC DISEASES

Please do not hesitate to contact our dedicated service unit for more details regarding this program at

LABORATORY REPORT 2. Measurement of Isotonic Strength & Power, Isometric Strength

This presentation focuses on recent changes in vaccine storage and handling requirements for the State Childhood Vaccine Program.

OH&S. Musculoskeletal Injury Prevention (MSIP)

OAI Operations Manual page 1 STANDING HEIGHT TABLE OF CONTENTS

ABSTRACT. Lance C. Dalleck 1, Devan E. Haney 1, Christina A. Buchanan 1, Ryan M. Weatherwax 1 ORIGINAL RESEARCH. Purpose:

Management of Central Venous Access Devices. Blood Glucose Monitoring

FROM GO TO GOAL! Your Blueprint to Fitness Success. On your mark, get set GOAL!

Dental Extraoral X-ray Systems

SMALL GROUP SESSION 13 December 1 st or December 3 rd

Thera-Band /Hand Weight Exercises

Dental Intraoral X-ray Systems

QUALITY ASSESSMENT (QA) MANUAL

Home Office Solutions By: Laura Cervantes QAS 515 3/26/03

Research. A comparison of blood pressure measurement over a sleeved arm versus a bare arm. The measurement of blood pressure is one of the

Medicare Part B Preventive Services: Quick Reference Chart January 2009

AN INTRODUCTION TO DOPPLER. Sarah Gardner, Clinical lead, Tissue viability service. Oxford Health NHS Foundation Trust.

DOELAP On-Site Assessment Requirements Checklist Page 1 of 24 Participant:

HOME BP USER INSTRUCTIONS

GROUP TRAINING MANIFESTO

Goal of site data management 12/2/2009. Ultimate goal: reliable and valid clinical trial to improve health

STRESS CAUSES OF STRESS METHODS OF MEASURING STRESS MANAGING STRESS

Critical Appraisal Series

Upper Extremity Venous Duplex Evaluation

Clinical Evaluation for. Embrace No Code Blood Glucose Monitoring System

How to Use Fellowes Sit-Stand Solutions

Basic Biostatistics. Dr. Kiran Chaudhary Dr. Mina Chandra

HOW TO WRITE A STUDY PROTOCOL

Exercises After Breast or Axillary Lymph Node Surgery

MARSHALLTOWN MEDICAL & SURGICAL CENTER Marshalltown, Iowa

MODEL POLICY FOR LAW ENFORCEMENT/PUBLIC-SERVICE PRE- EMPLOYMENT POLYGRAPH SCREENING EXAMINATIONS. 1. Introduction Evidence-based Approach...

Webinar Logistics. Now What Do I Need To Do? Blood Pressure in Kids January NC Department of Health and Human Services Division of Public Health

Measuring body temperature, blood pressure, pulse, respiratory rate and oxygen saturation

Study Design and Materials

This guide is intended as a reference only, not as a medical manual BY TFIT GYM LLC

UNIT 4 ASSESSMENT OF NUTRITIONAL STATUS

Transcription:

QC QUALITY CONTROL IN CLINICAL STUDIES Tuesday, January 25, 2010 Jack M. Guralnik, M.D., Ph.D. Laboratory of Epidemiology, Demography and Biometry National Institute on Aging g

Outline I. Need for Quality Control II. III. IV. Quality Control of Clinical Procedures Identifying Appropriate Data for Quality Control Study Procedures for Quality Control V. Data Editing VI. Bias Resulting from Poor Quality Control

I. Need for Quality Control (after Hulley SB and Cummings SR, Designing Clinical Research, Williams and Wilkins, Baltimore,1988) A. To assure quality of data and avoid systematic bias or random error leading to erroneous or uninterpretable results Bias: Any process at any stage of inference which tends to produce results or conclusions that differ systematically from the truth

B. Missing data 1. Can be disastrous if affects large proportion of measurements 2. If missing i in non-random way (and almost always is) leads to bias in results 3. Often biases toward null but not always 4. Examples: self-report of disease status, income, pulmonary function test, treadmill exercise tolerance testing 5. Best way to deal with missing data is to prevent them from occurring

C. Inaccurate or imprecise data 1. Often remain undiscovered, especially if measurements made by more than one person 2. Typically due to inappropriate technique (poor calibration, biased interrogation, rushed or sloppy measures), often distributed randomly with regard to participant characteristics

3. Less often but more concerning are systematic differences in measurement techniques associated with participant characteristics: obese or unfit persons allowed to hold hand rails in exercise testing; persons with emphysema permitted to shorten exhalation time in spirometry testing

II. Quality Control of Clinical i l Procedures A. Steps that precede study 1. Develop manual of operations a. Clear operational definitions of eligibility, recruitment, measurement procedures b. Standardized instruments and forms c. Approaches to analyzing data 2. Train and certify research team 3. Establish procedures for monitoring data quality

Formal Certification Procedures 1. Determine during gplanning gphase which components of study require certification Include not only examination procedures but also interviewing, data entry procedures, consenting and randomization, interventions, blood collection and processing 2. Certification form that is kept on file 3. Certification checklist

LIFE Components Requiring Certification Short Physical Performance Battery Blood Pressure Weight, Height Waist Circumference 400 m walk test Medication Inventory Grip Strength Blouse/Shirt Test Lateral Mobility Task (WFU) Cognitive Tests (WFU and Stanford) Blood Collection Blood Processing Interviewing (HRQL and MMSE) CHAMPS Data Entry Behavioral Run-in Administration and Assessment Physical Activity Intervention Successful Aging Intervention Program Coordinator Note that for all components, the following tasks must be completed: (1) Attendance at the LIFE centralized training session or training by someone certified in the measurement/procedure; (2) Required reading: Manual of Procedures Chapters 1 (Protocol) and 24 (Quality Control). (3) Plus additional items listed on the certification forms (Appendix A).

Certification/Recertification (example) Seated Blood Pressure Name 1. Attendance at central training session or Date Local training by a staff member certified in the procedure. Date Name of Trainer Description of local training: 1.Become familiar study website. 2.Required Reading Chapter 1, Protocol Chapter 4, General Procedures Chapter 6, Screening Chapter 8, Follow-up Visits Staff ID Chapter 16, Physical Measures Chapter 24, Quality Control 4. Conduct 3 blood pressures, record on the Blood Pressure, Radial Pulse & Weight Form. Trainer uses and completes the Seated BP Certification Checklist during observation of the procedure. 5. Date of Certification Signature of Program Coordinator Date Signature of Principal Investigator Date

Certification/Recertification Checklist (example) Seated Blood Pressure Name Staff ID During Procedure: 1. Keeps participant warm, relaxed and comfortable 2. Discourages participant from talking except to voice discomfort or confusion about instructions Observes the Following Procedural Steps: 1.Assembles proper materials and equipment:: standard mercury sphygmomanometer, 4 cuff sizes, measuring tape, cosmetic marking pencil 2.Greets participant and reviews purpose, time requirement and procedure. 3.Seats participant in proper position - both feet flat on floor, right forearm resting on table 4.Determines appropriate cuff size by following protocol for measurement of arm circumference. Measures length of arm from acromion to olecranon process, marks midpoint on arm. Measures arm circumference at mid-point, determines cuff size from MOP chart 5.Records arm circumference, cuff size and arm measured on data form 6.Measures and records radial pulse 7. Places cuff properly with center of bladder over the brachial artery and cuff at the level of participant's heart 8.Palpates brachial artery and estimates MIP 9.Confirms participant is relaxed and comfortable and reminds of the need to be seated quietly for 5 minutes prior to the measurement 10.Observes the 5 minutes of relaxed sitting 11.Obtains 2 blood pressure measures with a 30 second interval between end of first reading and beginning of second reading 12.Records both BP readings correctly on the data forms 13.Communicates appropriately with participant regarding a normal or an alert BP Comments: Observer: Date Observed:

B. Steps during study 1. Conduct quality control procedures on regular schedule throughout the study 2. Provide steady and visible leadership 3. Hold regular staff meetings 4. Reward staff for finding quality control "opportunities" " 5. Avoid casting blame which encourages staff to hide errors

6. Maintain minimum schedule of performances of procedures (e.g., at least once per week) to maintain certification 7. Recertify research team periodically 8. Tabulate measures by technicians, compare variability, means

III. Identifying appropriate data for quality control A. Cost of controlling everything is prohibitive B. May need less attention in blinded, randomized clinical trials as random errors should be distributed evenly between treatment groups C. Focus on patient t safety factors, key exposure variables, and outcome measures

1. Patient safety a. Consent forms and consent process b. Integrity of randomization scheme c. Effects and side-effects of treatment (blood pressure in antihypertensive trial, coagulation measures in anticoagulation trial, etc.) d. Drug administration (correct drug and dosage, correct code on participant bottle)

2. Major risk factors such as smoking, alcohol intake, cholesterol level 3. Subclinical or clinical disease assessments a. Ultrasound measurements of atherosclerosis: central reading, blinded d to participant i t characteristics, duplicate measures to assess inter- and intra-reader reproducibility

b. Tissue diagnosis of cancer: duplicate readings of all or sample of pathology specimens IV. Study Procedures for Quality Control A. Spot checks or repeats of interviews, exam findings, etc. B. Repeat of tests (EKGs, laboratory tests) 1. Same reader or lab blinded to subject 2. Different readers or labs

C. Check forms for omissions or major errors while subject still in clinic i 1. No errors or transpositions of ID number 2. ID number, name code, study name on each page 3. No missing entries or faulty skip patterns 4. Entries legible 5. Values of key variables within permissible range 6. Values of key variables are consistent with each other: hysterectomy y or estrogen use in men

B. Program computer to flag missing or outof-range values C. Ensure accuracy of participant i t ID number with check digit or duplicate entry D. Enter data in duplicate or check accuracy of entry by hand in random sample

E. Examine frequency distributions periodically to identify aberrant values or less than expected degree of variability F. Credos 1. Quality control problems will occur. a. Have a system in place that will identify them b. Fix them as early as possible 2. Data which are collected without any ongoing quality checks are best left uncollected

V. Data editing A. Should be completed prior to data analysis, though h often errors crop up only once data begin to be used B. Internal consistency and validity checks should be developed 1. Detect recording, coding, entry errors (prostate problems in women) 2. Identify inappropriate codes

C. Types of errors 1. Non-normative (clearly wrong) errors- usually easy to detect a. Inconsistent or illegal codes (for yes/no or 0/1 data, sex = 3; death = 4, etc.)

b. Missing values (find out why missing-- must have ongoing editing of forms, best done immediately after completion while participant still available) c. Outliers-- plot and examine (see below 2. Normative errors a. Data entry, transcription errors b. Extremely difficult to detect t 1. Check each value with data form or record

2. Enter data twice and compare files-- unlikely to make same data entry error twice 3. Take random sample and verify with data form or record D. Identification of outliers 1. Widely differing values for one or a few individuals requires scrutinizing data to be sure no coding, data entry or recording errors occurred

2. Outlier test (Tukey) a. Rank data, divide into percentiles (quartiles) b. Identify 25th, 75th percentiles, difference between them (interquartile range) c. Define upper limit as 75th percentile plus interquartile range d. Define lower limit as 25th percentile minus interquartile til range e. Reanalyze without outliers, report both

3. Easier to exclude data if reason for extreme value is known 4. Prudent judgment should prevail VI. Bias in Clinical Trials: Special Issues in QC A. Minimal requirements for a bias-free RCT 1. Establish comparable study groups which are free of selection bias

2. Use standard treatment procedures which are reproducible 3. Develop data collection schedule where probability of observing an event, given that it has occurred, is the same for all patients B. Standardization as a means of bias control 1. Manual of operations 2. Description of treatment procedure 3. Standard definitions

4. Standard equipment 5. Standardized data forms with check lists C. Checks for bias 1. Periodic checks on baseline comparability of study groups 2. Breakdowns in the random allocation process 3. Differential rate of treatment refusals 4. Differential rate of dropouts 5. Unnecessary unmasking

6. Questionnaire to check on efficacy of masking at end of study 7. Protocol violations which are differential by treatment group 8. Differences in variance of readings by treatment group D. "Correction" for bias 1. No method of adjustment available 2. Early detection important 3. Purging of data may be necessary

4. Stopping of trial may be necessary 5. Reporting in publications is essential E. Don t rush into field work (observational studies and RCT s) s). Take adequate time to plan QC activities and to properly p train staff.