Bio-logic AuDX PRO FLEX Screening tympanometry and audiometry Quick start guide

Similar documents
QUICK START GUIDE TYMPANOMETRY AND AUDIOMETRY FOR SENTIERO DESKTOP DEVICES

Bio-logic AuDX PRO FLEX Quick start Quick start guide

QUICK START GUIDE SENTIERO DESKTOP OAE AND TYMP SCREENER (BLUE HOUSING)

QUICK START GUIDE SENTIERO DESKTOP DIAGNOSTIC (WHITE HOUSING)

Bio-logic AuDX PRO FLEX Diagnostic OAE and audiometry Quick start guide

QUICK START GUIDE SENTIERO HANDHELD OAE AND AUDIOMETRY SCREENER (GREEN LABEL)

QUICK START GUIDE SENTIERO OAE, TYMP AND AUDIOMETRY SCREENING ( and )

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard

Table of Contents Morning Set-up (GSI equipment, only)... 2 Opening AudBase... 3 Choosing a patient... 3 Performing Pure-Tone Air & Bone

Oscilla - excellence since 1960

AMBCO 1000+P AUDIOMETER

Quick guide to connectivity and the Interton Sound app

This document presents the reader with instructions on using AudBase in the UCSF environment. AudBase Guidebook. Application How-To.

AT235/AT235h Middle Ear Analyzers. Diagnostic & clinical tympanometry with basic audiometry.

Biologic AuDX/Welch Allyn Quick Screen Instructions ECHO Training/Workshops

Neuro-Audio Version 2010

Advanced. NEW! Four times faster DPOAE: concurrent measurement of both ears while recording two DPs simultaneously in each ear!

TYMP Technical data. at 85, 95 und 105 db HL. 2. detailed display symbols

AURICAL Plus with DSL v. 5.0b Quick Guide. Doc no /04

SHOEBOX Audiometry Pro. Quickstart Guide. SHOEBOX Audiometry Pro

MI 44 Operating Instructions

The following describes general use of ELIOS device

RELEASED. Clearing your active insulin

Dosimeter Setting Device

Step-by-Step RECD Guide

by Maico Diagnostics

MADSEN Zodiac Diagnostic & Clinical Stand-alone

MI 26 Operating Instructions

Operating Instructions MAICO MI 26

Operating Instructions MI 24

AudioConsole. User Guide. Doc. No EN/01 Part No EN

Quick guide to connectivity and the ReSound Smart 3D app

TruLink Hearing Control App User Guide

ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE VEMP ECochG MLR P300

MA 25 Operating Manual

Diabetes Management App. Instruction Manual

Recharge. Relax.Repeat.

User Manual Verizon Wireless. All Rights Reserved. verizonwireless.com OM2260VW

Operating Instructions Race Car Tympanometer w/ Audiometer

CROS System Initial Fit Protocol

AT235 Middle Ear Analyzer. Diagnostic & clinical tympanometry with basic audiometry

Sleep Apnea Therapy Software User Manual

ENZO 3D First fitting with ReSound Smart Fit 1.1

Connectivity guide for ReSound Smart 3D app

ReSound ENZO 3D fitting guide. A guide for professionals

CMS-50E Instructions by Cooper Medical Supplies (These instructions are to supplement the manufacturer s user manual not to replace it!

USING THE MINIMED 670G SYSTEM. Instructions for the Experienced MiniMed 630G System User

User Guide. For Jacoti Hearing Center Version 1.1. Manufacture Year 2016

ABOUT THIS MANUAL READ THIS OPERATING MANUAL BEFORE ATTEMPTING TO USE THE INSTRUMENT.

Reliable, flexible & precise

How to Use the myhearing App on Apple/iOS devices

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

AMBCO AUDIOMETER

Data Management System (DMS) User Guide

Contour Diabetes app User Guide

Handheld OAE-Tympanometry Combination System

User's Manual Tympanometer Earscan ES-TRAM Document ID: PUB-114 Revision B

myphonak app User Guide

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

Product Model #: Digital Portable Radio XTS 5000 (Std / Rugged / Secure / Type )

Beltone Solus Pro 1.9 Fitting Guide

Thrive Hearing Control Application

How to Demo Phonak Brio TM 3 R-C

AA222 / AA220. Audio Traveller. Save time on routine. Focus on results. Interacoustics. leading diagnostic solutions

Fitting System Instructions for Use

EA 87. Clinical Impedance. Audiometer. User Manual

User Manual. - Pro Edition -

ER75 Electro-Acoustic Ear Simulator. Operating Manual

User Manual. RaySafe i2 dose viewer

Table of Contents. Contour Diabetes App User Guide

IHearYou The award-winning self-fit hearing aid system. A detailed guide (April 2018).

Hearing Control App User Guide

AMBCO 2500 AUDIOMETER SYSTEM WITH FIVE YEAR WARRANTY

Quick Guide to the Nucleus CR230 Remote Assistant. Getting started Quick reference

Quick Guide Binaural REM

Using Multi-Curve in Real-Ear Measurements on the 6500-CX Hearing Aid Analyzer

For Electric Personal Dosimete Dose-i

User Manual. - Pro Edition -

Sleep Apnea Therapy Software Clinician Manual

SOFTWARE INSTRUCTION MANUAL

OAE Test System. Screener PLUS. Diagnostic PLUS. with 4 frequency DPOAE testing Protocols

GRASON-STADLER HEARING ASSESSMENT SYSTEMS

QUICK SETUP GUIDE SECULIFE DFBASE

Connectivity guide for ReSound Smart 3D app

ERO SCAN. OAE Test System. Screener. Diagnostic. with 4 frequency DPOAE testing Protocols

ProSense 307/347/367 Reviewer's Guide

Pure 312 Nx, Pure 13 Nx

MADSEN AccuScreen OAE & ABR Screener

Connectivity guide for. BeMore app

USING THE MINIMED 670G SYSTEM

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device.

Science made smarter. Titan. Advanced made flexible. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

Diagnostic Impedance & Audiometry in one solution

EPIC-PLUS System for auditory evoked potentials and neuro-otology. PEA - VEMPs ASSR - E-ABR FACIAL NERVE

Hanwell Instruments Ltd. Instruction Manual

ERO SCAN. Otoacoustic Emission Testing

Transcription:

AuDX PRO FLEX Screening tympanometry and audiometry Quick start guide Doc. No.7-26-1374-EN/00 Part No.7-26-13704-EN Natus Medical Denmark ApS. +45 45 75 55 55. otoinfo@natus.com Natus Medical Incorporated. 1-800-289-2150. otoorder.us@natus.com www.otometrics.com

AuDX PRO FLEX Screening tympanometry and audiometry Device connectors On/Off button Power supply USB cable Probe Headphones or second transducer Start menu Label printer Patient response button Air Pump Please note that not all Start Menu options will be available depending on the configuration of your device Battery status Current time Customize settings Turn off device Select patient Additional information about options for current screen 2

AuDX PRO FLEX Screening tympanometry and audiometry Testing: Tympanometry Select the Tymp: Tymp +1kHz button from the start menu and connect the probe to the red connector and the air cable to the pump connector. Select the test ear by pressing either the Right or Left ear icon. Cartoon mode will show an airplane on the screen during the tympanometry test. Connect a second transducer to the blue connector for Contralateral Reflex testing. Probe Second transducer Air Pump Select the appropriate ear tip size and place it on the probe tip. Insert the probe in the ear making sure that the ear tip fits tightly into the ear canal. Tympanometry and reflexes Select one of the options in purple by tapping the corresponding button on the Full Color Touch Screen. Tymp: TY + REF: 226 Hz Tymp with a 1 KHz ipsi screening relfex at 90 & 95 db, Auto Start (see next page). Tymp: QUICK: 226 Hz Tymp, Auto Start, As Fast As Possible, Stop when Result obtained. Please make sure you have selected a tip, placed it on the probe and inserted it properly in the patient s ear so it fits securely. Clip the probe to collar or clothing. Selecting an Autostart Protocol (screening shown here) will start the test automatically when right or left is selected. Make sure the tip is in the ear prior to choosing Right or Left. Check Probe Fit Screen appears (see picture at far right). Once you receive green check marks by Probe Fit and Pressure, the test will proceed automatically. If you do not get green checks (above-open) during the calibration phase, check the probe fit, refit and retry. 3

AuDX PRO FLEX Screening tympanometry and audiometry Tympanometry test screen The system will first check the probe fit and wait for the pressure build up. The LED light on the probe will pulse at a steady pace to indicate a correct fit. During the test, if the probe fit is not correct, the LED light will blink at a fast pace and an error message prompting you to retry or cancel the test will appear on the screen. Once a proper seal has been obtained, the test will proceed. A tympanometry test will be performed, followed by a reflex measurement (when Tymp + 1kHz selected). Tympanometry result Reflex test in progress Reflex threshold found Overall Reflex test result 4

AuDX PRO FLEX Screening tympanometry and audiometry For manual testing: use green arrow buttons to change intensity For manual testing: use green arrow buttons to change reflex frequency For manual testing: tap this button if you choose to change test pressure from Tymp Peak Pressure (TPP) Available Actions from the bar at the bottom of the screen (from left to right): Stop test to return to Immittance Menu Push Play to continue testing manually Push Magnifying Glass to review reflex results Push the Ear button at the bottom to switch test ears. Push this button for help about this screen 5

AuDX PRO FLEX Screening tympanometry and audiometry If you push the Magnifying Glass button to view results, you will have the actions below available: Tap the result square to return to the test screen and repeat Please note that the polarity of the reflex graphs can be configured in the device settings under Test Preferences /Tymp Preferences. Tap to return to Reflex test screen Tap for on Board help about this screen Tap to scroll down for more reflex results Tap to view Printing options When you press the Stop Test button, a message box appears: Stopping Measurement, asking you if you would like to save the test data. If you choose YES, the data will be saved and test results will be displayed. If you choose NO, you will be taken back to the Module Selection. Choose CANCEL to stay on the test screen. View the Printing Quick Guide for Additional Information regarding printing your test data. Note: While performing Tympanometry, holding the probe or moving your hand may cause noise or an error. This will cause the device to stop automatically and give you the message Artifact? If this happens, refit the probe, check tip size to make sure it fits securely in the ear canal opening, and retry by tapping on the red play button. 6

AuDX PRO FLEX Screening tympanometry and audiometry Audiometry (screening) Select the Audiometry: Screening button from the start menu and connect the headphones to the blue connector. Select the ear on which you want to start the test. Audiometry Select the Audio: Screen button from the start menu Make sure that the device is turned on and that the headphones are plugged into the blue jack on the back of the device. Place the headphones over the patient's ears with the red colored connector on the cord of the headphone on the right ear and the blue one on the left ear. Position the patient looking away from the examiner controls Choose the ear to be screened by tapping on Right or Left in the Audio View. 7

AuDX PRO FLEX Screening tympanometry and audiometry Audiometry test screen Select the frequency Select the ear to test Select the Select the stimulus levels Stop test Press to present the stimulus Select the type of stimulus: pure tone pulsed tone or warble Additional information about options for current screen As you present the stimulus, the current level will be displayed on the corresponding (yellow) square. Once the hearing status for a frequency has been identified, move on to the next frequency. Tapping twice on a square will display NR (no response). Tap three times to get back to a blank square. Once all frequencies have been tested for one ear, you can test the other ear. 8

AuDX PRO FLEX Screening tympanometry and audiometry When the test is finished, press the Stop button. You can add the patient s personal data, and save on the device, print to a label (a label printer is required) or print to a pdf file or full page report on PC. Begin a new session by tapping the green patient icon at the center of the bottom bar and then tapping the icon (below right). Start a new patient by tapping the icon. Or to add patient details before testing (only available in diagnostic devices) 9

AuDX PRO FLEX Screening tympanometry and audiometry Quick Guide Information Release date: 2017-01-12 Revision: 02 Valid from: Firmware Rev. 2.1, Mira PC Software Rev. 1.6.4 Applies to: Model: SOD100497, web description SOD01, SOD02 and SOD03. All mentioned items, products, brands and trademarks are registered or owned by the mentioned companies. All information, illustrations, and specifications provided within this manual are based on the latest product information available at the time of publication. PATH medical reserves the right to make changes at any time without notice. Please note that not all products displayed on our webpage or advertising materials are available in all territories. Please contact your local distributor or PATH medical for further information. The latest revision of the Quick Start Guide is available online at www.pathme.de/download. Errors and omissions excepted. Copyright Notice No part of this manual may be reproduced, translated, stored, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written consent of PATH medical GmbH. Copyright 2016 PATH medical GmbH PATH medical GmbH Landsberger Straße 65 82110 Germering Germany Tel: +49 89 800 76 502 Fax: +49 89 800 76 503 Internet: www.pathme.de 10