NANOINDENTATION STUDY OF NORMAL AND OSTEOPOROTIC BONES

Similar documents
Nanomechanical Symptoms in Cartilage Precede Histological Osteoarthritis Signs after the Destabilization of Medial Meniscus in Mice

MECHANICAL PROPERTIES OF A SINGLE CANCELLOUS BONE TRABECULAE TAKEN FROM BOVINE FEMUR

Osteoporosis New Insights

Intra-Articular Tibiofemoral Injection of a Nonsteroidal Anti-Inflammatory Drug has no Detrimental Effects on Joint Mechanics in a Rat Model

Nanoindentation of trabecular bone in human vertebrae classified as normal, osteopenic and osteoporotic by ultrasonometry of the calcaneus

Engineering Approaches to Age-related Diseases

Thickness Computation Under In-Vivo Trabecular Bone CT Imaging

CT Imaging of skeleton in small animals. Massimo Marenzana

Introduction to Biomedical Engineering: Basic concepts and Bone Biomechanics

BIOLOGY and BIOMECHANICS OF NORMAL & OSTEOPOROTIC BONE

Thomas A. Metzger, Stephen A. Schwaner, Jonelle M. Shudick, Anthony J. LaNeve, Glen L. Niebur. University of Notre Dame, Notre Dame, IN, USA.

Characterizing the Mechanical Properties of Bone with the Assistance of Digital Light Microscopy

Frictional Behavior and Surface Failure of Human Enamel

Anisotropy of Tensile Strengths of Bovine Dentin Regarding Dentinal Tubule Orientation and Location

TissueSurgeon Hard Tissue Applications

ON THE MICROHARDNESS AND YOUNG S MODULUS OF HUMAN TEETH

Assessing Bone Quality in Terms of Bone Mineral Density, Buckling Ratio and Critical Fracture Load

Available online at ScienceDirect

Number Crunching: How and When Will Numerical Models Be Used in the Clinical

Ethan M. Braunstein, M.D. 1, Steven A. Goldstein, Ph.D. 2, Janet Ku, M.S. 2, Patrick Smith, M.D. 2, and Larry S. Matthews, M.D. 2

Introduction. Original Article. Abstract

Microstructural changes in the bone tissue and in the bone callus of diabetic rats with and without insulin treatment

Relationship between the Apex of Flexible Nail and the Level of Fracture: A Biomechanical Study Ahmed N* 1, Gakhar H 2, Cheung G 3, Sharma A 4

Musculoskeletal Research

Effect of the femoral stem size on femur bone quality towards THR

Imaging Choices in Occult Hip Fracture

Analysis of an Early Intervention Tibial Component for Medial Osteoarthritis

Bone as a Structural Material

operative technique Kent Hip

Stretching Cardiac Myocytes: A Finite Element Model of Cardiac Tissue

Anabolic Therapy With Teriparatide Indications Beyond Osteoporosis

Beyond BMD: Bone Quality and Bone Strength

THE STRAIN-RATE DEPENDENCE OF MECHANICAL PROPERTIES OF RABBIT KNEE LIGAMENTS

In-Silico approach on Offset placement of implant-supported bridges placed in bone of different density in Orthodontics.

Comparitive Study between Proximal Femoral Nailing and Dynamic Hip Screw in Intertrochanteric Fracture of Femur *

ISSN: ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 2, Issue 12, June 2013

Validating FE predictions of distal radius failure load: standard region and 4% region

Effects of Whole Body Exposure to Electromagnetic Field on Normal and Osteoporotic Bone Metabolism in Rats

Modélisation par éléments finis des effets des médicaments sur le remodelage osseux : Approche mécanobiologique

Types of Plates 1. New Dynamic Compression Plate: Diaphyseal fracture: Radius, Ulna, Humerus, Rarely tibia

Prediction Of Pathological Fracture In The Proximal Femora With Bone Lesions Using A CT Scan-based Finite Element Method

QUARTZ SPLINT. Our fiber expertise is your strength TM.

Online Journal Club-Article Review

Silvia Capuani*, Giulia Di Pietro*, Guglielmo Manenti, Umberto Tarantino^

Trabecular bone analysis with tomosynthesis in diabetic patients: comparison with CT-based finite-element method

Micro-CT imaging of surgical screw tightening in human trabecular bone

MEDILINK PEGASUS Smart. The New Portable ultrasound Bone densitometer

Test the Mechanical Properties of Articular Cartilage using Digital Image Correlation Technology

AOTrauma Course Fragility Fractures and Orthogeriatrics

Bone mechanics bone strength and beyond

Beyond BMD: Bone Quality and Bone Strength

Biomechanical Analysis of Hip Joint Arthroplasties using CT-Image Based Finite Element Method

Age changes in the human femoral neck and progression to failure. Functional Adaptation in the Femoral Neck

Introduction to Biomedical Engineering

Viscoelastic properties of demineralized human dentin measured in water with atomic force microscope (AFM)-based indentation

Observations on the Geometric Distribution of Micro-structural Features in Cortical Bone

Femur Condylar Plate System Procedural Steps.

Disclosures. Beyond BMD: Bone Quality & Bone Strength. Design of a Structure. Fractures = structural failure of the skeleton

PROPHECY. Preoperative Navigation Guides ANKLE CT SCAN PROTOCOL

L.W. Sun 1,2, G. Beller 1, D. Felsenberg 1. Introduction. Original Article. Abstract

Anterior Approach Surgical Technique. Paragon Stem System. enabling people to enjoy life

AC : ELASTIC MODULUS OF BONE USING ULTRASONIC TESTING

Developments in bone grafting in veterinary orthopaedics part one

SalvinOss Xenograft Bone Graft Material In Vivo Testing Summary

Original Article. Kazuhiro Imai. Department of Life Sciences, Graduate School of Arts and Sciences, The University of Tokyo, Tokyo, Japan

Quantitative Analysis of Vascular Canals in Vertebral Endplate

LION. Application Note PRECISION. Linear Position Measurement with Eddy-Current Sensors. LA March, Applicable Equipment: Applications:

Virtual Stress Testing of Regenerating Bone in Tibia Fractures

For the Perfect Class V and All Cervical Area Gingival Margins when Placing Direct Composites, Create an Injection Molding Matrix

EXPERIMENTAL ANALYSIS OF STRESSES IN REAL (PRESERVED) INTACT PROXIMAL HUMAN FEMUR (THIGH) BONE UNDER STATIC LOAD

The host bone mass is critical to oral implantation

Modeling of human knee joint and finite element analysis of landing impact motion

Molecular Cartography:

Mineral Density Of Subchondral Bone May Be Quantitatively Evaluated Using A Clinical Cone Beam Computed Tomography Scanner

Exploring the Effect of Pore Size and Distribution on Shear Strength of Surface Porous Polyetheretherkeytone (PEEK)

Siglec-15 Is A Potential Therapeutic Target For Postmenopausal Osteoporosis

Imaging of Respiratory Disorders: M2 Pathology correlated with Radiology

CASE REPORT. CBCT-Assisted Treatment of the Failing Long Span Bridge with Staged and Immediate Load Implant Restoration

The Effect of Varying Bisphosphonate Treatment on Changes in Bone Microdamage in Osteoporotic Women

Stress Injuries in the Young Athlete 3 rd Annual Young Athlete Conference Greg Canty, MD Medical Director, Center for Sports Medicine Asst Professor

15th Asia-Pacific Conference for Non-Destructive Testing (APCNDT2017) Singapore, November 16, 2017

Imaging the musculoskeletal system. An Introduction

The shape and size of femoral components in revision total hip arthroplasty among Chinese patients

Chapter 2 Cancellous Bone

This is a repository copy of Microarchitecture of bone predicts fractures in older women.

Bone Investigational Toolkit BIT. Biomechanical Bone Integrity Assessment

Skeletal and Muscular Systems. Bone myths

New Dual-energy X-ray Absorptiometry Machines (idxa) and Vertebral Fracture Assessment

Simulation of Ridge Formation in Cortical Bone near the Anterior Cruciate Ligament Insertion: Bone Remodeling due to Interstitial Fluid Flow

The role of the calcar femorale in stress distribution in the proximal femuros4_

Technical Report FORCE ATTENUATION CHARACTERISTICS OF DIFFERENT FORCE ABSORBING MATERIALS USED IN A HIP PROTECTOR FOR THE ELDERLY

Modal Analysis of Hip Joint Implant Used In the Human Body

Top: Healthy Vertebrae Above: Osteoporotic bone

How Much Tesla Is Too Much?

Double Engine Orthopedic Bone Nail System Universal Humeral Nail

Long-term Wear Evaluation of an Artificial Medial Meniscus Implant

RBM dental implants by CST Process Technical Release September 2012

JOINT RULER. Surgical Technique For Knee Joint JRReplacement

Creation of Patient-Specific Bone Densitometry Models from 3D Imaging Data

Finite Element Analysis of Radius and Ulna. Eli Pavlatos April 24, 2013

Transcription:

NANOINDENTATION STUDY OF NORMAL AND OSTEOPOROTIC BONES C.T. Lim, B.H.B. Omar and J.C.J. Goh 1 Division of Bioengineering & Department of Mechanical Engineering, 1 Department of Orthopaedic Surgery, National University of Singapore, Singapore ABSTRACT This paper investigates the nanomechanical properties of both normal and osteoporotic rat femur bones using the nanoindentation technique. Here, the Young s modulus and hardness were determined at specific locations within the bone. Microtomography was also used to evaluate the morphological differences between the bones. In general, the mechanical strength of osteoporotic bone was found to be lower than normal bone and the trabecular part more porous. The spatial resolution with which testing was carried out mattered in identifying the mechanical property and morphological differences at the micron and nanometer scale between normal and osteoporotic bones. This can help in the research on the diagnosis of osteoporosis or testing the efficacy of certain treatment methods. 1 INTRODUCTION Osteoporosis is a major cause of morbidity, mortality and medical expenses worldwide. This increase is expected to continue with an aging population and as more people adopt a sedentary lifestyle and a poor diet. An osteoporosis sufferer has a lower bone mass and experiences structural deterioration of the bone tissue. As such, an osteoporosis patient can be susceptible to fractures even from activities such as sneezing or giving a hug. The question arises whether this structural deterioration is manifested as a change in the arrangement of the matrix that makes up the bone or just an intrinsic weakening of the individual bone filament. This paper seeks to investigate this by examining the nanomechanical properties of both normal and osteoporotic bones using the nanoindentation technique. 2 MATERIALS AND METHODS Ten female Wistar rats were used in this study. An ovariectomy was performed on five of these rats. The bones were stored with flesh at -20ºC to maintain their mechanical properties (Cowin [1]). Only the femurs were used in the experiments. The left femurs were first imaged using microtomography. The right femurs were tested using the nanoindentation technique. To prevent demineralization of the bone, the soft tissue was removed using a scalpel instead of immersion in potassium hydroxide. For nanoindentation, the right femur bone was embedded in acrylic mould 28 mm in diameter, up to 1 cm from the distal end. This allowed the femur to be clamped so that sawing and polishing could be performed. The femur was cut longitudinally 2 mm from the centre of the shaft using a diamond saw. The surface was polished with grit paper and alumina slurry. Following that, another cut is made 2 mm from the polished surface. The sample was then attached to a glass slide using cyanoacrylate adhesive. A Triboscope indenter mounted on a Digital Instrument Dimension 3100 atomic force microscope was used for the nanoindentation tests. A berkovich tip was used for indentation and imaging. For every sample, eight indents were made on the cortical bone. Figure 1 shows the location of the indents. The load was increased linearly to a maximum load of 2000µN over a period of 10 seconds. The load is then held constant for 15 seconds before it is reduced to zero over a period of 10 seconds. The 15-second hold period is essential as bone materials are known to possess rate dependent behavior. The Young s modulus and hardness were then calculated from the loaddisplacement data (Oliver et al [2]).

void locations of indentations Figure 1: Location of indents Figure 2: Slice of bone analysed using microtomography A Skyscan 1076 micro-ct was used for the microtomography experiments. All the scans were carried out at 18µm resolution at the proximal end as shown in Figure 2. The images obtained from microtomography are then used to form a three-dimensional model. From this model, the trabecular thickness and trabecular separation of the sample was obtained. The statistical software Minitab 14 was used to conduct a one-way analysis of variance (ANOVA) on the results. All tests were done at 0.05 level of significance. 3 RESULTS AND DISCUSSION The results of the nanoindentation tests are shown in Table 1. The values of Young s modulus and hardness for the normal bones are slightly higher than that reported by (Jamsa et al. [3]) by 21 and 38%, respectively. This could be due to the rats used in this experiment being older (6 weeks) than those used by Jamsa (2 weeks). The different strain of rat or diet could have also resulted in the discrepancy in the strength values. The values of Young s modulus and hardness of osteoporotic bone were found to be 19 and 40%, respectively and were lower than that of the normal bone. Osteoporosis has an obvious effect on the Young s modulus and hardness of the rat femurs.

Table 1: Mean values of Young s modulus and hardness from nanoindentation Normal Rat Young s modulus Hardness Rat Young s modulus Hardness N1 23.54 1.23 O1 19.73 0.76 N2 22.15 1.14 O2 18.75 0.66 N3 25.88 0.90 O3 18.30 0.61 N4 24.26 1.19 O4 19.46 0.69 N5 22.24 1.06 O5 19.16 0.54 Mean ± S.D 23.61 ± 1.55 1.10 ± 0.13 Mean ± S.D 19.08 ± 0.57 0.65 ± 0.08 The morphological differences between the normal and osteoporotic bones were evident from the images obtained from micro-ct as shown in figure 3 while those obtained from scanning electron microscopy (SEM) are shown in figure 4. The normal bone showed a thicker trabecular structure with smaller marrow spaces and higher bone density whereas the osteoporotic bone had thinner trabecular structure with wider marrow space and lower bone mass density. The trabecular thickness and separation obtained from the three-dimensional model from micro-ct is shown in Table 2. The osteoporotic bones showed a trend of lower trabecular width (35%) and higher trabecular separation (85%). This is similar to that reported by Yang et al. [4]. 1mm normal 1mm osteoporotic Figure 3: Microtomography image of normal and osteoporotic bone

Normal Figure 4: SEM images of normal and osteoporotic bones Normal bone bone Table 2: Trabecular thickness and separation of section of rat femur Rat Thickness/ mm Separation/ mm -1 N1 0.1289 0.1659 N2 0.1159 0.1727 N3 0.1302 0.1696 N4 0.1324 0.1569 N5 0.1158 0.1579 Mean ± S.D 0.1246 ± 0.00812 0.1646 ± 0.00701 O1 0.0823 0.3022 O2 0.0870 0.2891 O3 0.0713 0.2766 O4 0.0928 0.3237 O5 0.0694 0.3313 Mean ± S.D 0.0806 ± 0.01006 0.3046 ± 0.02294 The results of the ANOVA test are shown in Table 3. The value of F 0.05 with 1 and 8 degrees of freedom is 5.32. Although the mean maximum load is lower for the osteoporotic bone than the normal bone, it wasn t statistically significant. However it is significant that osteoporosis had an effect on the Young s modulus, hardness, trabecular thickness and trabecular separation of the rat femur. More interestingly the value of F for the Young s modulus and hardness are lower than that of the trabecular thickness and separation. Osteoporosis has been known to result in morphological changes whereas the sub-micron level mechanical properties were less explored. The results showed that both changes occurred in osteoporotic bone but the morphological changes are noted to be more significant. Table 3: Value of F 0.05 of various properties measured Material and morphological properties Value of F 0.05 Maximum load 2.55 Young s modulus 45.88 Hardness 42.74 Trabecular thickness 58.10 Trabecular separation 170.18

The above study can benefit from the following improvements that can be made. Firstly, the normal and osteoporotic rats should be of the same age when sacrificed so as to exclude the effect of physiological changes on bone property. Secondly, the experiments which had been conducted over a period of several weeks should preferably be conducted immediately after sacrifice so as to minimize the effect of bone degradation. 4 CONCLUSIONS Nanoindentation and microtomography are reliable techniques in assessing the quality of bone at the micron and nanometer scale. In addition, the findings of more obvious changes in morphology at the micron level might help in more accurate or earlier diagnosis of osteoporosis. It can also be used to study the efficacy of various treatment methods. 5 REFERENCES 1) Cowin, S., Bone Mechanics, CRC Press, pp 20-6 pp 20-9, 2001 2) Oliver, W.C., Pharr, G.M., An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments, Journal of Materials Research, Vol. 7, pp 1564-1583, 1992. 3) Jamsa, T., Rho, J.Y., Fan, Z., Mackay, C. A., Marks Jr. S. C., Tuukkanen, J., Mechanical properties in long bones of rat osteopetrotic mutations, Journal of Biomechanics, Vol. 35, pp 161-165, 2002. 4) Yang, J., Pham, S.M., Crabbe, D.L., Effects of oestrogen deficiency on rat mandibular and tibial microarchitecture, Dentomaxillifacial Radiology, Vol. 32, pp 247-251, 2003.