Application Note. Authors: C. Ledesma, M. Gibert, J.R. Gibert Ingenieria Analitica S.L. Extracts from various food products

Similar documents
Mono- and Disaccharides

Iodide in Milk. Electrochemistry Discover the difference

Carbohydrates in Food

[ APPLICATION NOTE ] Profiling Mono and Disaccharides in Milk and Infant Formula Using the ACQUITY Arc System and ACQUITY QDa Detector

Analysis of Food Sugars in Various Matrices Using UPLC with Refractive Index (RI) Detection

Application Note. Sensitive analysis of the lactose content of lactose-free labelled products using HPAEC-PAD. Summary.

ANTEC LEYDEN. Analysis of Carbohydrates in Food and Beverages using Anion-Exchange Chromatography and Pulsed Amperometric. Introduction.

Sugar analysis according to the EU Regulation using amperometric detection and Metrosep Carb 2-150/4.0

The Determination of Sugars in Molasses by High-Performance Anion Exchange with Pulsed Amperometric Detection

Bisphenol A in Drinking Water

Analysis of Lactose and isomers in Lactose-free labelled products

Determination of Carbohydrates in Kombucha Using HPAE-PAD

Carl Fisher, Terri Christison, Hua Yang, Monika Verma, and Linda Lopez Thermo Fisher Scientific, Sunnyvale, CA, USA

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

Transferring a Method for Analysis of DNPH-Derivatized Aldehydes and Ketones from HPLC to UHPLC

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column

Profiling of Endogenous Metabolites Using Time-of-Flight LC/MS with Ion Pair Reverse Phase Chromatography

Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system

Analysis of Counterfeit Antidiabetic Drugs by UHPLC with the Agilent 1220 Infinity Mobile LC

Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system

A HPAE-PAD Chromatographic Assay for Carbohydrates in Urine as a Measure of Intestinal Permeability

RP-HPLC Analysis of Temozolomide in Pharmaceutical Dosage Forms

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

Application Note. Small Molecule Pharmaceuticals. 2-Ethyl-2-phenylmalonamide Ethosuximide Primidone Carbamazepine. Carbamazepine-

Development, Estimation and Validation of Lisinopril in Bulk and its Pharmaceutical Formulation by HPLC Method

Application Note. Abstract. Author. Biotherapeutics & Biosimilars. Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany

HPAE-PAD Determination of Infant Formula Sialic Acid

Performance Characteristics of the Agilent 1290 Infinity II Multicolumn Thermostat

Application Note. Agilent Application Solution Analysis of fat-soluble vitamins from food matrix for nutrition labeling. Abstract.

Betadex Sulfobutyl Ether Sodium According to USP

Increasing resolution using longer columns while maintaining analysis time Advantages of the wide power range of the Agilent 1290 Infinity LC System

columns CarboPac PA20 Column

Sugars in Honey Using HPAE-PAD: What Is the Best Column?

Confident, lower-pressure analysis of carbohydrates, alcohols, and organic acids. Agilent Hi-Plex Ligand-Exchange HPLC Columns

Betadex Sulfobutyl Ether Sodium according to USP

Sialic Acid Determination in Glycoproteins: Comparison of Two Liquid Chromatography Methods. Experimental. Introduction. Method 1.

SACCHARIDES (Liquid Chromatography)

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate

Chiral Multicolumn Method Development on the Agilent 1260 Infinity II SFC System

Quantitative Analysis of Carbohydrates and Artificial Sweeteners in Food Samples Using GFC- MS with APCI Interface and Post-column Reagent Addition

Oligosaccharide Profiling of O-linked Oligosaccharides Labeled with 2 Aminobenzoic Acid (2-AA)

Qualitative and quantitative determination of cannabinoid profiles and potency in CBD hemp oil using LC/UV and Mass Selective Detection

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages

Analysis of bisphenol A leaching from baby feeding bottles

Comparison of a UPLC Method across Multiple UHPLC Systems

Agilent Anion-Exchange Media for Proteins - Loading vs Resolution - Effect of Flow Rate and Example Protein Separations

Authors. Abstract. Introduction. Environmental

Glycoprotein monosaccharide analysis using HPAE-PAD with manually prepared eluent

SIMULTANEOUS ESTIMATION OF VALSARTAN AND HYDROCHLOROTHIAZIDE IN TABLETS BY RP-HPLC METHOD

A New Stability-Indicating and Validated RP-HPLC Method for the Estimation of Liraglutide in Bulk and Pharmaceutical Dosage Forms

Qualitative and quantitative determination of phenolic antioxidant compounds in red wine and fruit juice with the Agilent 1290 Infinity 2D-LC Solution

Edgar Naegele. Abstract

METHOD 8316 ACRYLAMIDE, ACRYLONITRILE AND ACROLEIN BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC)

HPLC Analysis of Sugars

Determination of Plant-Derived Neutral Oligo- and Polysaccharides Using the CarboPac PA200

Simultaneous Analysis of Active Pharmaceutical Ingredients and Their Counter-Ions Using a Mixed-Mode Column

Performance characteristics of the Agilent 1100 Series preparative pump. Technical Note. Abstract

Ultrafast analysis of synthetic antioxidants in vegetable oils using the Agilent 1290 Infinity LC system

Determination of Amantadine Residues in Chicken by LCMS-8040

Agilent 1260 Infinity Analytical Hybrid SFC/UHPLC system

Lipidomic Analysis by UPLC-QTOF MS

ISSN: ; CODEN ECJHAO E-Journal of Chemistry 2011, 8(3),

Determination of Lactose in Lactose-Free Milk Products by High-Performance. anion-exchange chromatography with. Pulsed Amperometric Detection

Rapid determination of phosphate and citrate in carbonated soft drinks using ion chromatography

Development and Validation of a Simultaneous HPLC Method for Quantification of Amlodipine Besylate and Metoprolol Tartrate in Tablets

Fast determination of residual glycerol and glycerides in biodiesel by SFC/MS using the Agilent 1260 Infinity Analytical SFC System

USP purity analysis of pravastatin sodium using the Agilent 1120 Compact LC

Analysis of Common Sweeteners and Additives in Beverages with the PerkinElmer Flexar FX-15 System Equipped with a PDA Detector

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

Development and validation of stability indicating RP-LC method for estimation of calcium dobesilate in pharmaceutical formulations

Determination of Carbohydrates in Beverages and Milk Products by HPAE-PAD and Capillary HPAE-PAD

Separation of 15 Underivatized Saccharide and Sialic Acid USP Standards

A NOVEL METHOD OF M/Z DRIFT CORRECTION FOR OA-TOF MASS SPECTROMETERS BASED ON CONSTRUCTION OF LIBRARIES OF MATRIX COMPONENTS.

LC-MS/MS analysis of Chlorates in Milk and Whey Powder using the Agilent 6470 QQQ

Development and Validation of a Polysorbate 20 Assay in a Therapeutic Antibody Formulation by RP-HPLC and Charged Aerosol Detector (CAD)

Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column

Tentu Nageswara Rao et al. / Int. Res J Pharm. App Sci., 2012; 2(4): 35-40

Thermo Scientific Dionex CarboPac MA1 Column

Journal of Pharmacreations

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR QUANTITATIVE ANALYSIS OF TRAMADOL IN PURE AND PHARMACEUTICAL FORMULATIONS

Quantitative Analysis of Underivatized Amino Acids in Plant Matrix by Hydrophilic Interaction Chromatography (HILIC) with LC/MS Detection

Analysis of Isoflavones with the PerkinElmer Flexar FX-15 UHPLC System Equipped with a PDA Detector

Agilent 1220 Infinity LC System Performance Specifications

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Determination of Bisphenol A in Milk Powder using a Chromolith HighResolution RP-18 endcapped column

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

HPLC to UHPLC Transfer of USP Method for Amlodipine Besylate Using the Agilent 1290 Infinity II LC

A Validated Chiral Liquid Chromatographic Method for The Enantiomeric Separation of Dapoxetine Hydrochloride

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP

Enhanced Detection Capabilities in Speciation Analysis Using a Highly Sensitive ICP-MS. Peio RISS ICP-MS Application Specialist.

Determination of Sucralose in Reduced- Carbohydrate Colas using High-Performance Anion-Exchange Chromatography with Pulsed Amperometric Detection

Extended Application Note

Reduced Ion Suppression and Improved LC/MS Sensitivity with Agilent Bond Elut Plexa

DEVELOPMENT OF RP-HPLC METHOD FOR ESTIMATION OF DROTAVERINE HYDROCHLORIDE IN PHARMACEUTICAL FORMULATIONS

Maximizing Efficiency Using Agilent InfinityLab Poroshell 120 Columns

CarboPac PA-100 Column for Oligosaccharide Analysis

Transcription:

High-Performance Anion-Exchange Chromatography coupled with Pulsed Electrochemical Detection as a powerful tool to evaluate lactose content in lactose-free labeled products Application Note Authors: C. Ledesma, M. Gibert, J.R. Gibert Ingenieria Analitica S.L. Category Matrix Method Keywords Analytes ID Food analysis Extracts from various food products HPAEC-PAD Lactose free, sugars, Carbohydrates/analysis sucrose, galactose, glucose, fructose, lactose and maltose PR1079,04/17 Abstract An analytical method based on an Agilent Infinity LC 1260 coupled to a Decade Elite Electrochemical Detector has been developed to accurately determine lactose in lactose-free products with different matrices. In addition, the methodology presented herein opens the possibility to quantify with high resolution and accuracy mixtures of 6 common carbohydrates (sucrose, galactose, glucose, fructose and lactose) from different sugar-free matrices in less than 10 minutes. Introduction The analysis of lactose has become very important in the last decades due to the increasing population who suffers from lactose intolerance. Nowadays it has been established, following the recommendations of the European Food Safety Authority, that the lactose-free products must contain less than 0.01% (100 ppm) of lactose. This limit, though, may decrease in the upcoming years and therefore it is necessary to develop a robust and accurate method to determine very low lactose concentration in lactose-free products even below actual recommended limits. Due to the high volume of carbohydrates that food industries process daily, a technique to analyze these compounds in the fastest way with minimum sample preparation is required. In addition, life sciences are also in need of methodologies to determine these compounds at very low concentration since carbohydrates take part of many important physiological processes. In this application a methodology based on an Agilent 1260 Infinity Binary LC coupled with a Decade Elite Electrochemical Detector from Antec Scientific has been developed to determine accurately lactose with proper resolution in the 0.1-100 ppm range. This methodology has been extended to 6 out of the most common carbohydrates: sucrose, galactose, glucose, fructose, lactose and maltose in a concentration range between 50 and 5000 ppm in food samples with different matrices by only adapting the injection volume of sample. No additional hardware changes are required.

Experimental Method parameters The HPLC analysis have been performed using an Agilent Analytical HPLC system consisting of a 1260 Infinity Binary pump (G1312B), 1260 Infinity High Performance Degasser (G4225A), 1260 Infinity High Performance Autosampler(G1367E), an analytical column and the Decade Elite electrochemical detector in multistep pulse mode. The applied anion exchange column is stored in the detector. The Decade Elite is equipped with a cell containing a 2 mm Au working electrode and a HyRef reference electrode, which requires very little maintenance. The use of multistep pulses keeps the surface of the working electrode in optimum conditions and no additional polishing is required. Moreover, the HyRef reference electrode versus the commonly used Ag/AgCl has the advantage that is maintenance free. MilliQ water, 18MΩ-cm resistance, filtered through a 0.2 µm filter has been used as a solvent for the mobile phase and the prepared standard solutions of lactose and the rest of carbohydrates, which contain a concentration range between 0.1-1000 ppm and 5-5000 ppm, respectively. The mobile phase consists of a solution of NaOH 100 mm prepared from a 50% w/w carbonate-free NaOH stock solution. The mobile phase is continuously sparged with N 2 to avoid further carbonation during the analysis. Alternatively, a CO2 filter can be used on top of the solvent bottle. Prior to the analysis of any set of samples and/or standard solutions the system has to be flushed and equilibrated during 30 min at the initial conditions (2 mm NaOH). The HPLC and detector parameters are summarized in Table 1 followed by a picture of the equipment (Figure 1). Column Mobile phase Flow rate Injection volume Temperature Detection Cell Detector range Multistep pulses CarboPac SA10 (4 x 250 mm) Binary gradient H2O NaOH, from 2-35 mm 1.8 ml/min 0.5-10 µl 40ºC (Column and flow cell) Pulsed Amperometric Detection with multistep pulses SenCell 2 mm Au HyRef 10 µa; 10 % offset E cell: E1, E2, E3, E4: +0.1, -2.0, +0.6, -0.1 V ts, t1, t2, t3, t4: 0.2, 0.4, 0.02, 0.01, 0.07 s I cell: >100 na Table 1. HPLC and PAD parameters Figure 1. HPLC Agilent 1260 Infinity series coupled with a Decade Elite Electrochemical Detector used in this study. The DECADE Elite can be used with any HPLC & (u)hplc system from Agilent Data acquisition uses an AD board input connected to the DECADE Elite 20-bit analog Output. CDS used: Agilent Openlab Chemstation For instrument control the keyboard can be used or the free Dialogue software is available. 2

Preparation of standard solutions and samples All the solutions have been prepared from a stock standard solution containing 1000 ppm of lactose, sucrose, galactose, glucose, fructose and maltose which were prepared dissolving 0.1 g of each carbohydrate in 100 ml of MilliQ water. The carbohydrates contained in food samples with different matrices were extracted using Carrez solutions where no further dilution of the sample was needed. After the extraction, the samples were filtered through a 0.2 µm filter and 10 µl were injected in the HPLC system. Results Determination of lactose in lactose-free products The calibration curve has been determined as the average of three consecutive calibration curves in the range 0.1 to 100 ppm. Figure 2. Calibration curve of the Lactose from 0.1 to 100 ppm The reproducibility of the retention time (RSD) is 0.2% after the three calibration curves have been measured. The detection and quantification limits for this technique by using these standard solutions have been calculated: Detection Limit: 0.003 ppm Quantification limit : 0.030 ppm This methodology has been applied in lactose-free milk samples and some of them have been doped with 10 ppm of lactose, respectively. The following figure (Figure 3) shows the chromatogram of the milk sample doped with 10 ppm of lactose. The lactose compound appears at 4.97 min under the given chromatographic conditions. 3

Figure 3. Chromatogram of Lactose-free milk doped with 10 ppm of lactose Moreover, it has also been demonstrated that the reproducibility of the retention time after 24 h of continuous analysis is 0.5%. A control calibration sample has been measured after 24 h of analysis and the difference in the retention time is 1.3% and the difference in the area is 0.2%. Under the chromatographic tested conditions, it has not been necessary any column conditioning step as it is not observed any retention time shifting. Figure 4. Repeatability (n10) of a Lactose-free milk sample doped with 10 ppm lactose Determination of carbohydrates in food samples The methodology developed for the analysis of lactose in lactose-free labeled products was extended to other carbohydrates within the same concentration range (up to 100 ppm). Figure 5 shows the chromatogram of a sample containing 100 ppm of each carbohydrate and their retention times, which have also been summarized in table 2. 4

Table 2. Retention time of each carbohydrate Compound Ret. time (min) Sucrose 2.96 Galactose 3.25 Glucose 3.67 Fructose 4.40 Lactose 5.26 Maltose 9.66 Figure 5. 6 Carbohydrates mixture sample (100 ppm) The calibration curves for each carbohydrate have been determined using the parameters listed in Table 1 and correlation factors higher than 0.99 have been obtained (Figure 6). 5

Figure 6. Calibration curves of the different carbohydrates from 0.1 to 100 ppm. In addition to these concentration levels, it has also been possible to accurately quantify mixtures of carbohydrates at concentration levels up to 5000 ppm without any hardware or configuration changes. It has been only necessary to decrease the injection volume to 0.5 µl, while the other parameters remain the same. The obtained calibration curves for each carbohydrate are illustrated hereafter. 6

Figure 7. Calibration curves of the different carbohydrates up to 5000 ppm. As an example, a chromatogram of a 5000 ppm mixture of the different carbohydrates is depicted in Figure 8. The retention times have been summarized in Table 3. No shifting of the retention times has been observed after repeated analysis. Table 3. Retention time of each carbohydrate Compound Ret. time (min) Sucrose 3.24 Galactose 3.61 Glucose 4.05 Fructose 4.94 Lactose 6.04 Maltose 9.97 Figure 8. Carbohydrate mixture sample (5000 ppm) Conclusions The Analysis of lactose in lactose-free products using an Agilent 1260 Infinity HPLC coupled with a Decade Elite Electrochemical Detector is now possible without the need of a bioinert HPLC configuration. The same methodology and instrument configuration can be extended to the analysis of 6 out of the most common carbohydrates in food samples within a wide range of concentrations (up to 5000 ppm) by only adapting the injection volume without any additional hardware changes. 7

References Carbohydrates in Food. Application Notes by ANTEC, 220_002_05 and 220_003_01 Cataldi, T.; Campa, C. & De Benedetto, G. Fresenius; Carbohydrate analysis by high-performance anion-exchange chromatography with pulsed amperometric detection: The potential is still growing J. Anal. Chem. (2000) 368: 739-758 Johnson, D.C.;Dobberpuhl, D.; Roberts, R.; Vandeberg, P.; Review: Pulsed amperometric detection of carbohydrates, amines and sulfur especies in ion chromatography-the current state of research J. Chromatogr. (1993) 640: 79-96 LaCourse, W.R.; Pulsed Electrochemical Detection in High Performance Liquid Chromatography John Wiley & Sons, New York, 1ed, 1997. El Rassi, Z.; Carbohydrate analysis: high performance liquid chromatrography and capillary electrophoresis Journal of Chromatography Library (1995) 58. Corradini, C.; Cavazza, A.; Bignardi, C.; High-Performance Anion-Exchange Chromatography Coupled with Pulsed Electrochemical Detection as a Powerful Tool to Evaluate Carbohydrates of Food Interest: Principles and Applications, International. Journal. of Carbohydrate Chemistry, (2012) 1-13. 8