Neuro-MS/D DIAGNOSTICS REHABILITATION TREATMENT STIMULATION. Transcranial Magnetic Stimulator. of motor disorders after the stroke

Similar documents
Neurosoft TMS. Transcranial Magnetic Stimulator DIAGNOSTICS REHABILITATION TREATMENT STIMULATION. of motor disorders after the stroke

Neuro-MS/D Transcranial Magnetic Stimulator

NEURO-MS TMS. Diagnostic Monophasic Magnetic Stimulator

Neuro-MEP-Micro EMG EP. 2-Channel Portable EMG and NCS System with a Built-in Miniature Dedicated Keyboard. EMG according to international standards

MAGPRO. Versatility in Magnetic Stimulation. For clinical and research use

Neuro-Audio Version 2010

ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE VEMP ECochG MLR P300

MagPro by MagVenture. Versatility in Magnetic Stimulation

MagPro by MagVenture. Versatility in Magnetic Stimulation

Introducing MagPro XP with Cool TwinCoil for Magnetic Seizure Therapy

Introduction to TMS Transcranial Magnetic Stimulation

Quick Guide. for Treatment of Depression. with Brainsway dtms

ISIS IOM. System-Family. The new ISIS Xpress supplements the ISIS IOM System-Family >> APPLICATION FIELDS: >> Powerful >> User-friendly >> Flexible

SUPER INDUCTIVE SYSTEM

TMS: Full Board or Expedited?

What is NBS? Nextstim NBS System

HANDS-FREE ULTRASOUND

AdvAnced TMS. Research with PowerMAG Products and Application Booklet

BME 701 Examples of Biomedical Instrumentation. Hubert de Bruin Ph D, P Eng

Statement on Repetitive Transcranial Magnetic Stimulation for Depression. Position statement CERT03/17

Soleoline, high-performance

Transcranial Magnetic Stimulation for the Treatment of Depression

Puls 2.0 Radial Pulse Therapy

Non-therapeutic and investigational uses of non-invasive brain stimulation

Patient Manual Brainsway Deep Transcranial Magnetic Stimulation (Deep TMS) System for Treatment of Major Depressive Disorder

Research Perspectives in Clinical Neurophysiology

Neurophysiological Basis of TMS Workshop

Neurostyle. Medical Innovation for Better Life

Moving Rehabilitation Forward. Intelect Neo. Navigation Reference Guide

Compressor Nebulizer. Guidebook

b e y o n d e x p e c t a t i o n

DCNV RESEARCH TOOL: INVESTIGATION OF ANTICIPATORY BRAIN POTENTIALS

EE 4BD4 Lecture 11. The Brain and EEG

Moving Rehabilitation Forward. Vectra Neo. Simplified, Powerful Solutions

myaudiometer. It s familiar, and it s so much

ENZO 3D First fitting with ReSound Smart Fit 1.1

Using Transcranial magnetic stimulation to improve our understanding of Transverse Myelitis

TESLA Stym REHABILITATION NEURO-PHYSIOTHERAPY SPORT MEDICINE

TABLE OF CONTENTS 1.1. WARRANTY DAMAGED SHIPMENTS SERVICE INTRODUCTION UNPACKING AND INSTALLATION

DEEP TMS TREATMENT CONSENT FORM

Experiment HH-3: Exercise, the Electrocardiogram, and Peripheral Circulation

Sleep diagnostics systems

Medescan Nebuliser Med - S600A Instructions Manual

OTAGO LIPOSURG. Compact, powerful system for infiltration and liposuction

Setting up a TMS Treatment Program

MRI GUIDELINES FOR INSPIRE THERAPY

Twelve right-handed subjects between the ages of 22 and 30 were recruited from the

THE NEW 4 SERIES. Complete, easy-to-use, fast and the responsible choice!

April 17, :53 Gymna 2010

The Most Outstanding Features & Benefits of Today s Auditory Evoked Potentials (AEP) Systems

Compressor Nebulizer. Guidebook

microprocessor controlled eddy current brake Load / accuracy Watt, speed independent / according to DIN VDE

Compressor Nebulizer System

Exercise 6: Muscle Physiology II Twitch & Summation

experiences that matter

Gymna ShockMaster 500

MRI GUIDELINES FOR INSPIRE THERAPY

EE 4BD4 Lecture 20. Therapeutic Stimulation

Quick Guide - eabr with Eclipse

PACEMAKERS ARE NOT JUST FOR THE HEART! Ab Siadati MD

INTRAORAL IMAGING ACCORDING TO YOUR NEEDS Intraoral X-rays

SONOPULS 490 SONOPULS 490

Power Spectrum Density Analysis of EEG Signals in Spastic Cerebral Palsy Patients by Inducing r-tms Therapy

Splitting of the characteristic K-alpha doublet radiation of molybdenum (Item No.: P )

TWO CHANNEL CLINICAL AUDIOMETER AUDIOSTAR PRO

MOTOR EVOKED POTENTIALS AND TRANSCUTANEOUS MAGNETO-ELECTRICAL NERVE STIMULATION

User Manual. RaySafe i2 dose viewer

MultiStim SWITCH and MultiStim SENSOR Setting the trend in nerve stimulation

Bio-logic AuDX PRO FLEX Screening tympanometry and audiometry Quick start guide

Exercise 2: Effects of Cold Temperature Aim: To record changes in heart rate after the heart is bathed in cold Ringer s solution.

Figure 1: The EVH board

Lesson 2 EMG 2 Electromyography: Mechanical Work

SpikerBox Neural Engineering Workshop

Heart Rate and Blood Pressure as Vital Signs

Humans make voluntary decisions to talk, walk, stand up, or sit down. The

Myofascial Acoustic Compression Therapy

USER MANUAL Please read before use

ECG SENSOR ML84M USER S GUIDE. CENTRE FOR MICROCOMPUTER APPLICATIONS

Power - Q1000. Digital 4 tiered rippling compressive limb and circulation therapy system

Desktop Fitting Guide for Phonak Brio 3

Water immersion modulates sensory and motor cortical excitability

Avaya Model 9611G H.323 Deskphone

Exercise 5: Muscle Physiology I - Electromyography

N4i Installation Manual. (picture of N4i screen)

QUICK START GUIDE TYMPANOMETRY AND AUDIOMETRY FOR SENTIERO DESKTOP DEVICES

Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion

Tune in on life with SCOLAbuddy. A new fm receiver from Widex

BERA The HOMOTH ABR / BERA- module is a real time brainstem audiometer. It is developed considering the latest knowledge of the ENT research.

Electromyography II Laboratory (Hand Dynamometer Transducer)

GRASON-STADLER HEARING ASSESSMENT SYSTEMS

Simple. Stress-free. The Newtron Ultrasonics Series

Chapter 5: Checking and Maintaining Ultrasound Equipment

TECH 2 Dew Point Retrofit Kit

Neurostimulation Systems

Repetitive transcranial magnetic stimulation (rtms) at Toronto Western Hospital

ASCO Power Control Systems Overview

NOVIN medical engineering Co. Designer and manufacturer of physiotherapy equipment

EPIC-PLUS System for auditory evoked potentials and neuro-otology. PEA - VEMPs ASSR - E-ABR FACIAL NERVE

Transcription:

Neuro-MS/D Transcranial Magnetic Stimulator DIAGNOSTICS of corticospinal pathway pathology REHABILITATION of motor disorders after the stroke TREATMENT of depression and Parkinson s disease STIMULATION with up to 100 Hz frequency, peak magnetic field up to 4 T and active coil cooling

20 YEARS IN TMS FIELD Neurosoft Company is a world leader in development and manufacture of transcranial magnetic stimulators (TMS systems). Our first stimulator was created in 1996. Nowadays, in almost 20 years of continuous development, we produce extensive line of TMS devices. Neuro-MS/D is the magnetic stimulator of fourth generation. Thousands of Neurosoft TMS machines operate in scientific laboratories, neurological and psychiatric clinics all over the world and TMS technique becomes a routine practice of neurologists and psychiatrists. WHAT IS TMS? PEAK MAGNETIC FIELD ACTIVE COIL COOLING The alternating magnetic field easily penetrates through skin, cranium bones, soft tissues and reaches the cortex. This field has extremely high intensity. If the coil is positioned over the motor cortex and the stimulus is delivered, the intensity of induced field is enough to activate big groups of motor neurons that results in a visible muscle twitch. Such impact is inaccessible for other types of stimulation and allows performing a wide range of diagnostic and therapeutic procedures. If the recording electrodes placed on the peripheral muscle are plugged in the EMG machine, and the muscle representation in the motor cortex is stimulated with the coil, the motor evoked potential (MEP) can be recorded. The study of the obtained waveform, its amplitude and latency allow estimating the state of the motor pathway starting from the cortex. The repetitive transcranial magnetic stimulation performed for a long time (about 10-30 minutes) can modulate the cortex excitability. For example, the excitability can be increased with high-frequency stimulation or decreased with low-frequency stimulation. The magnetic stimulation has proven therapeutic effect at different psychiatric and neurological disorders. TMS APPLICATIONS PSYCHIATRY: treatment of depressions, schizophrenia, obsessive-compulsive disorders, manias and other disorders. NEUROLOGY: diagnostics of motor pathway disorders, treatment of tinnitus, consequences of stroke, spasticity, pain syndrome, migraine, Parkinson's disease. RESEARCH: study of brain functions and motor pathways. Peak magnetic field of Neuro-MS/D reaches 4 T. This is one of the highest values in the industry. Patients suffering from brain disorders may sometimes have decreased motor cortex excitability. To ensure the desired stimulation effect in such patients, it is required to perform high-intensity stimulation. SOFTWARE The stimulator can operate in stand-alone mode when all the parameters are adjusted using the stimulator controls located on the front panel or under Neuro-MS.NET software control. Neuro-MS.NET software allows keeping patient database, detecting motor thresholds, managing the treatment courses and stimulation sessions. The software is equipped with the preset protocols for treatment of neurological and psychiatric diseases. There is no need to search the stimulation parameters for treatment of depression, Parkinson's disease or other disorders in books, articles or manuals, you just select the protocol from the list and start the treatment. One of the problems related to therapeutic magnetic stimulator use is quick overheating of coils during the stimulation. We designed special cooling unit and cooled coils to cope with this problem. The cooling unit allows increasing the running time without overheating up to 10 000 pulses iteratively. In practice it means that the device can operate for hours without overheating. STIMULATION WITH UP TO 20 HZ FREQUENCY To achieve the therapeutic effect, it is required to perform stimulation with specified frequency. The researchers all over the world create and test continuously new therapeutic TMS protocols. Often it assumes that the high-frequency stimulation is required. Neuro-MS/D performs stimulation at up to 100 Hz frequency (up to 25 Hz with maximum intensity). All these allow using most advanced and modern treatment protocols.

STIMULATOR COMPONENTS MAIN UNIT Main unit controls all other units and can be used as a stand-alone machine (if equipped with the coils). The front panel contains digital indicators displaying all parameters of stimulator and controls used to adjust parameters. To attach the stimulator to PC, main unit has USB socket. COOLING UNIT The cooling unit is a significant part of therapeutic magnetic stimulator. There is a tank with cooling agent inside it, high-tech compressor-free cooler and the pump running continuously the cooling agent via the coil. The liquid cooling system is much more efficient and less noisy in comparison with the air one. EXTRA POWER SUPPLY UNIT The main unit of the magnetic stimulator is designed to operate with up to 30 Hz frequency. However, the main unit alone can deliver maximum intensity only at 5-7 Hz frequency. The extra power supply unit makes it possible to increase the maximum frequency up to 100 Hz and obtain the maximum intensity at 20-25 Hz frequency depending on coil type. FLEXIBLE ARM FOR COIL POSITIONING During the stimulation it is very important to keep the coil in one and the same position relative to patient s head. Only in this case one can be sure that the stimulus is delivered in the targeted brain area. Moreover, the location of cortex depends on individual anatomic features. Thus, at the beginning of the procedure the clinician must be free to move the coil relative to patient s head to detect the stimulation area and then instantly fix the coil securely at any position. To ensure such fixation, Neuro-MS/D can be supplied with special flexible arm for coil positioning. NEURO-MS.NET SOFTWARE The Windows-based software intended to control the magnetic stimulator allows keeping the patient database, managing the treatment courses and the stimulation sessions, performing the stimulation using the predefined protocols and also creating and customizing the available stimulation protocols. The software is optimized for touchscreen interface. NAVIGATION SYSTEM EMG AMPLIFIER Neuro-MS/D can be supplied with 2-8 channel EMG machine*. When connected to the computer, it can be used to record the motor evoked potentials obtained at stimulation of the motor cortex and peripheral nervous system. *Neurosoft offers a wide range of EMG systems: 2-channel Neuro-EMG-MS and Neuro-MEP-Micro, 4-channel Neuro-MEP-4, 5-channel Skybox and 8-channel Neuro-MEP-8. Most clinicians, using the magnetic stimulators, apply anatomical landmarks to detect the stimulation area. Such stimulation, sometimes, is not enough accurate because of individual anatomical peculiarities of subjects. Recently there was developed a new technique that allows entering MRI data of a particular subject to computer before the stimulation session and perform MRI-guided stimulation using the 3D target markers on patient s brain rendering. Neuro-MS/D stimulators can be used together with navigation system.

COILS OF NEW GENERATION The Neuro-MS/D magnetic stimulators can be supplied with different coils. All coils have ergonomic handle. The device readiness indicator and pulse delivery button are integrated into this handle. The coil is equipped with the reliable high-voltage connector used to plug the coil to the main unit. The wide range of cooled coils is also available. The cooled coils are equipped with quick connect couplings that allow fast coil attachment to the cooling unit excluding cooling agent leakage. No tools are required for coil replacement. Thus, even the cooled coil replacement takes a few seconds. Besides the classical coils the double cone coil is designed. It is intended for deep brain stimulation. Neurosoft Company can design the special coils upon customer s request. PEAK MAGNETIC FIELD AT 100% STIMULUS AMPLITUDE, T 1.5 (3.2)* 1.3 (2.8)* 2.5 (5.2)* 1.2 (2.6)* 1.5 (3.2)* 1.4 (3)* IMAGE NON-COOLED COILS Small ring coil RC-02-100 Big ring coil RC-02-150 Small figure-of-eight coil SFEC-02-50 Figure-of-eight coil FEC-02-100 Figure-of-eight coil (placebo) FEC-02-100-P Angulated figure-of-eight coil AFEC-02-100 Angulated figure-of-eight coil (placebo) AFEC-02-100-P Double cone coil DCC-02-125 COOLED COILS Cooled big ring coil RC-02-150-C Cooled figure-of-eight coil FEC-02-100-C Cooled angulated figure-of-eight coil AFEC-02-100-C Cooled angulated figure-of-eight coil (placebo) AFEC-02-100-C-P Cooled double cone coil DCC-02-125-C *If research configuration is used.

WWW.NEUROSOFT.COM, INFO@NEUROSOFT.COM PHONES: +7 4932 24-04-34, +7 4932 95-99-99 FAX: +7 4932 24-04-35 5, VORONIN STR., IVANOVO, 153032, RUSSIA