Protect your expensive HPLC and UHPLC columns from premature failure with MAC-MOD Pre-Column Filters

Similar documents
Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases

The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns.

PEEK SS Columns & Guard Columns

PEEK Columns & Guard Columns

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE

ACE CN-ES. Extra Stability. Extended Spacer. Enhanced Selectivity ACE. Combining CN polar selectivity with enhanced hydrophobicity

Hyper-fast & Super-rugged

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis

ACE C18-AR Use the Power!

Comparison of a UPLC Method across Multiple UHPLC Systems

InertSustainBio C18. Rapid Separations of Proteins and Peptides

Product Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis

Biphenyl. Stationary Phase: Fast, Rugged Raptor Columns with Time-Tested Selectivity. Pure Chromatography. Selectivity Accelerated

ARC-18. Stationary Phase: Ahead of the Curve for Large, Multiclass Lists by Mass Spec. Pure Chromatography. Selectivity Accelerated.

Core-Shell Technology for Proteins and Peptides

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate

Chromatogram Search Tool Search by compound name, synonym, CAS # or keyword Pinnacle II Columns

SecurityGuard. Column Protection for UHPLC, HPLC to PREP. A Universal Guard Cartridge System. Increases HPLC Column Lifetime, Guaranteed!

Am I getting the very best value from my UHPLC analyses?

HPLC. Varian Dynamax Preparative HPLC Columns

Calibration Standards

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

ACE ACE. HPLC and UHPLC Columns. Product Catalog

Product Guide for LudgerSep TM C3 anion exchange HPLC Column for Glycan Analysis

Choosing Preparative Columns

Application Note. Separation of clindamycin phosphate and process impurities. Summary. Introduction. Category Pharmaceutical analysis Matrix

Raptor HILIC-Si: Simplify the Switch to HILIC

ACE Excel UHPLC Columns

Columns for HPLC. Columns for HPLC

Raptor HILIC-Si: Simplify the Switch to HILIC

CANNABIS TESTING ACCESSORIES

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit

For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns.

Ultra Columns HPLC COLUMNS

Cam & Groove Fittings. King Nipples

ACE HILIC + + UHPLC and HPLC Columns. For Reproducible Polar Analyte Separations. Three HILIC Column Chemistries Available

Inline Filters (F Series) Catalog 4130-F July 2005

COST, PROCESS & QUALITY IMPROVEMENT

Caleva tablet dissolution baths normally use cannula style filters with a large range of porosities. 100 Pack 1000 Case. 100 Pack 1000 Case

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit

Ultra Columns. also available. ordering note

Quick Sealing with a Twist to Connect Actuation Method

USP Method Transfer of Ziprasidone HCl from HPLC to UPLC

LC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined

Overview on YMC Column Hardware and Phases

Agilent Anion-Exchange Media for Proteins - Loading vs Resolution - Effect of Flow Rate and Example Protein Separations

The Raptor HILIC-Si Column

Installation and Maintenance Instructions

QuickSplitTM Flow Splitters

Thermo Scientific Hypersil BDS Columns

The One Minute Chromatographer

Overview on YMC Column Hardware and Phases

Product Guide for LudgerSep TM R1 HPLC Column for Glycan Analysis

LC Columns and Accessories

Savillex Technical Note

TSKgel Hydrophobic Interaction Chromatography Columns

Thermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific

Analytical and Preparative SFC Columns

HC-75 Calcium Form. 305 x 7.8 mm HC-75 Calcium Form (P/N 79436)

LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column

Preparative Chromatography Meets UHPLC

QuickSplit TM Flow Splitters

Maximizing Efficiency Using Agilent InfinityLab Poroshell 120 Columns

Needle Valves Catalog 4110-NV December 2010

CLINDAMYCIN PALMITATE

Normal Phase HPLC Column COSMOSIL SL-II

Savillex Technical Note

GlycanPac AXH-1 Columns

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079

Increasing resolution using longer columns while maintaining analysis time Advantages of the wide power range of the Agilent 1290 Infinity LC System

Compressor Accessories

INTERNATIONAL PHARMACOPOEIA MONOGRAPH ON LAMIVUDINE TABLETS

Restek Ultra II HPLC Columns

Ion Exchange Chromatography COSMOGEL IEX Series Columns

PRA International Early Development Services Bioanalytical Laboratory

Lipidomic Analysis by UPLC-QTOF MS

Simply GCxGC GC GC Made Simple and Easy to Use

Rapid Separation of Fatty Acid Methyl Esters

CYCLOSERINI CAPSULAE - CYCLOSERINE CAPSULES (AUGUST 2015)

HPLC to UHPLC Transfer of USP Method for Amlodipine Besylate Using the Agilent 1290 Infinity II LC

APPLICATIONS TN Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex 2.6 µm Core-Shell Technology Column

Filtration Approaches to Sample Preparation and Cleanup. Golnar Javadi Application Engineer Sample Preparation Products

Core-Shell / Solid core Particles: A Practical Substitute to Sub-2 Micron Particles: An overview

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Agilent 1260 Infinity Analytical SFC System

BabyBio IMAC columns DATA SHEET DS

Exploiting Selectivity in HPLC and UHPLC With Rational Stationary Phase Design

DRAFT PROPOSAL FOR THE INTERNATIONAL PHARMACOPOEIA: CARBAMAZEPINI COMPRESSI - CARBAMAZEPINE TABLETS

GlycanPac AXR-1 Columns

Advanced Column Designs and Innovative Packing Procedures

Agilent Technologies Prep LC Columns

Analysis of Food Sugars in Various Matrices Using UPLC with Refractive Index (RI) Detection

Purification - Flash Chromatography

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column

Abstract. Introduction

Choose for Your Instrument. GC Supplies - Shimadzu Instrument Quick Pick Guide

Agilent Captiva Sample Preparation Filtration Portfolio GAUGE THE DIFFERENCE FILTRATION CAN MAKE

Transcription:

Protect your expensive HPLC and UHPLC columns from premature failure with MAC-MOD Pre-Column Filters

Over 70% of the failures of HPLC columns are caused by inlet frit plugging. MAC-MOD Pre-Column Filters One of the most common causes of HPLC column failure is particulate material collecting on the inlet frit of the column, causing high back pressure and/or distortion of peak shape. By one estimate, over 70% of the failures of HPLC columns are caused by inlet frit plugging. UHPLC columns, especially those packed with sub-2 μm size particles, are particularly vulnerable to inlet frit plugging. MAC-MOD Analytical offers three different pre-column filters, each designed for column specific protection.

UltraShield Pre-column filters for UHPLC and UPLC columns As the name implies, UltraShield pre-column filters are engineered specifically for use in fast, high efficiency UHPLC separations requiring high mobile phase velocities and ultra-high pressure. The ultra-low dispersion of UltraShield maintains the efficiency of UHPLC columns, assuring no loss of critical resolution. With its simple design, UltraShield installs on any analytical, UHPLC or UPLC column in seconds and is leak tight to 1000 bar (15,000 psi). Simply finger tighten initially, then wrench tighten beyond finger tight an additional ¼ turn. Proof of the low dispersion of UltraShield This comparison of chromatograms illustrates that an UltraShield pre-column filter can be installed on a UHPLC column (HALO C18, 4.6 x 50 mm) with negligible affect on performance. Without Ultrashield With UltraShield installed on UHPLC column 480 430 480 2 430 2 380 330 280 230 180 130 80 30 380 1 1 330 280 3 3 230 180 130 80 30 0 0.5 1 1.5 2 2.5 Time (min.) 0 0.5 1 1.5 2 2.5 Time (min.) Peak 1 Peak 2 Peak 3 N w/o UltraShield 10,542 11,459 10,796 N with UltraShield 10,307 11,457 10,784 % Change -2.2% 0% -0.1%

ColumnShield Pre-column filters for higher performance HPLC columns or smaller bore columns 3.5 μm and 3.0 μm particles are often packed in HPLC columns with smaller bores (<3.0 mm ID) and shorter lengths (20-50mm). These columns facilitate faster separations and are routinely employed with mass spectrometers as detectors. The operating pressure is not as high as with UHPLC columns, but the need still exists for low system dispersion, since these columns typically generate peaks with small volumes. ColumnShield pre-column filters are optimal for these types of columns. They provide effective, low-dispersion filtering at a lower cost than the UltraShield. Although they are not recommended for ultra-high pressure applications, they can still be safely used at pressures up to 400 bar (6,000 psi). ColumnShield pre-column filters utilize a PEEK finger-tight design that connects directly to any 1 /16 10-32 internal thread inlet fitting port, regardless of the manufacturer. ColumnSaver Pre-column filter for more typical standard bore (3.0 to 8.0 mm) HPLC columns ColumnSavers provide economical protection for HPLC columns packed with 3 μm size particles or larger and with bore sizes (internal diameter) 3.0 mm to 8.0 mm. We even recommend using these pre-column filters on the inlet of guard columns to extend the life and reduce the replacement costs of these items. Product Guarantee All MAC-MOD Analytical pre-column filters are backed by our no hassle product guarantee. If, for any reason, you are not satisfied with any of these pre-column filters, you may exchange them for other pre-column filters or return them for a full refund.

Pre-column Filter Selection Chart Maximum HPLC/UHPLC HPLC/UHPLC Pre-column Pressure Column ID Column Length Filter 1000 bar 1.0 to 4.6 mm 30 to 250 mm UltraShield 400 bar 1.0 to 4.6 mm 50 to 250 mm ColumnShield 300 bar 2.1 to 8.0 mm 50 to 300 mm ColumnSaver Ordering Information UltraShield Item Description Part Number Price UltraShield Pre-column Filter, 0.5 μm porosity titanium filter element, 5/pkg MMUS-1505 $165.00 UltraShield Pre-column Filter, 0.5 μm porosity titanium filter element, 10/pkg MMUS-1510 $325.00 ColumnShield Item Description Part Number Price ColumnShield Pre-column Filter, 0.5 μm porosity stainless steel filter element, 5/pkg MMPF-205 $100.00 ColumnShield Pre-column Filter, 0.5 μm porosity stainless steel filter element, 10/pkg MMPF-210 $195.00 ColumnSaver Item Description Part Number Price ColumnSaver Pre-column Filter with 0.5 μm stainless steel filter element, 5/pkg MMCS-205 $90.00 ColumnSaver Pre-column Filter with 0.5 μm stainless steel filter element, 10/pkg MMCS-210 $165.00 analytical inc. For more information or to place an order, call MAC-MOD at 1-800-441-7508 or visit www.mac-mod.com

analytical inc. 103 Commons Court P.O. Box 587 Chadds Ford, PA 19317 Phone: 800-441-7508 Fax: 610-358-5993 Website: www.mac-mod.com Email: info@mac-mod.com