Visi-Pitch IV is the latest version of the most widely

Similar documents
AEROWIN RT: CLINCAL APPLICATION

Shaheen N. Awan 1, Nancy Pearl Solomon 2, Leah B. Helou 3, & Alexander Stojadinovic 2

Advanced Audio Interface for Phonetic Speech. Recognition in a High Noise Environment

COMPUTER PLAY IN EDUCATIONAL THERAPY FOR CHILDREN WITH STUTTERING PROBLEM: HARDWARE SETUP AND INTERVENTION

ACOUSTIC AND PERCEPTUAL PROPERTIES OF ENGLISH FRICATIVES

MES 9000 MUSCULOSKELETAL EVALUATION SYSTEM

Using VOCALAB For Voice and Speech Therapy

HCS 7367 Speech Perception

Initial - AR. Learning Objectives: Using This Lesson Effectively: CompleteSpeech

9/29/2017. Stuttering Therapy Workshop. Objectives today: Holistic Treatment. Data collection

Thought Technology Ltd.

11 Music and Speech Perception

MedRx HLS Plus. An Instructional Guide to operating the Hearing Loss Simulator and Master Hearing Aid. Hearing Loss Simulator

Beltone Solus Pro 1.9 Fitting Guide

Interjudge Reliability in the Measurement of Pitch Matching. A Senior Honors Thesis

2/25/2013. Context Effect on Suprasegmental Cues. Supresegmental Cues. Pitch Contour Identification (PCI) Context Effect with Cochlear Implants

PATTERN ELEMENT HEARING AIDS AND SPEECH ASSESSMENT AND TRAINING Adrian FOURCIN and Evelyn ABBERTON

Interact-AS. Use handwriting, typing and/or speech input. The most recently spoken phrase is shown in the top box

Phoneme Perception Test 3.0

Essential Speech Skills for School-Age Children Who Stutter

Waves Sibilance User Guide

Voice Pitch Control Using a Two-Dimensional Tactile Display

Quarterly Progress and Status Report. Effect on LTAS of vocal loudness variation

METHOD. The current study was aimed at investigating the prevalence and nature of voice

SoundRecover2 the first adaptive frequency compression algorithm More audibility of high frequency sounds

Speech (Sound) Processing

Feedback and feedforward control in apraxia of speech: Noise masking effects on fricative production.

International Forensic Science & Forensic Medicine Conference Naif Arab University for Security Sciences Riyadh Saudi Arabia

The following information relates to NEC products offered under our GSA Schedule GS-35F- 0245J and other Federal Contracts.

Acoustic Correlates of Speech Naturalness in Post- Treatment Adults Who Stutter: Role of Fundamental Frequency

Price list Tools for Research & Development

VPAT for Apple MacBook Air (mid 2013)

The Most Outstanding Features & Benefits of Today s Auditory Evoked Potentials (AEP) Systems

School of Health Sciences Department or equivalent Division of Language and Communication Science UK credits 15 ECTS 7.5 Level 7

Jitter, Shimmer, and Noise in Pathological Voice Quality Perception

Computational Perception /785. Auditory Scene Analysis

REDUCTION IN STUTTERING BY DELAYED AND FREQUENCY SHIFTED AUDITORY FEEDBACK: EFFECTS OF ADAPTATION AND SEX DIFFERENCES

ASU Speech and Hearing Clinic Spring Testing. Adult Speech and Language Evaluation

Effects of speaker's and listener's environments on speech intelligibili annoyance. Author(s)Kubo, Rieko; Morikawa, Daisuke; Akag

Oral Presentation #6 Clinical Analysis of Speech Rhythms in Language Development using MATLAB

iclicker+ Student Remote Voluntary Product Accessibility Template (VPAT)

The first choice for design and function.

Your Guide to Hearing

Effects of Music In Autistic Children and their Behavior Dr. T. MYTHILY Ph. D

Initial. Learning Objectives: Using This Lesson Effectively: CompleteSpeech

Summary Table Voluntary Product Accessibility Template

Getting Started with AAC

The effect of wearing conventional and level-dependent hearing protectors on speech production in noise and quiet

Frequency Tracking: LMS and RLS Applied to Speech Formant Estimation

2012, Greenwood, L.

Step-by-Step RECD Guide

Introduction. What s new in Genie 2? New Fitting features. Support for new hearing aids:

Speech Spectra and Spectrograms

Tune in on life with SCOLAbuddy. A new fm receiver from Widex

ITU-T. FG AVA TR Version 1.0 (10/2013) Part 3: Using audiovisual media A taxonomy of participation

Where experience connects with innovation

FONIX FP35. Ease and Accuracy with the FP35 Touch Hearing Aid Analyzer! Visible Speech

FORCEWIN RT: CLINICAL APPLICATION

Binaural processing of complex stimuli

iclicker2 Student Remote Voluntary Product Accessibility Template (VPAT)

The Effects of Improved Auditory Feedback on the Verbalizations of an Autistic Child

SYLLABUS FOR PH.D ENTRANCE TEST IN SPEECH AND HEARING

whether or not the fundamental is actually present.

Summary Table Voluntary Product Accessibility Template. Supporting Features. Supports. Supports. Supports. Supports

Roger TM Plug in, turn on and teach. Dynamic SoundField

Fitting System Instructions for Use

Sonic Spotlight. Binaural Coordination: Making the Connection

Speech as HCI. HCI Lecture 11. Human Communication by Speech. Speech as HCI(cont. 2) Guest lecture: Speech Interfaces

Combination of Bone-Conducted Speech with Air-Conducted Speech Changing Cut-Off Frequency

Voluntary Product Accessibility Template (VPAT)

Assistive Listening Technology: in the workplace and on campus

Critical Review: Do Speech-Generating Devices (SGDs) Increase Natural Speech Production in Children with Developmental Disabilities?

UvA-DARE (Digital Academic Repository) Perceptual evaluation of noise reduction in hearing aids Brons, I. Link to publication

Best Practice Protocols

The Benefits and Challenges of Amplification in Classrooms.

Web site:

R: Initial - Pr. Learning Objectives:

Summary Table Voluntary Product Accessibility Template. Supports. Please refer to. Supports. Please refer to

Voice Switch Manual. InvoTek, Inc Riverview Drive Alma, AR USA (479)

A Review on Dysarthria speech disorder

Consonant Perception test

Introduction. What s new in Genie 2?


HARP An Autonomous Speech Rehabilitation System for Hearing Impaired People FINAL REPORT

Fig. 1 High level block diagram of the binary mask algorithm.[1]

SLHS 1301 The Physics and Biology of Spoken Language. Practice Exam 2. b) 2 32

VPAT Summary. VPAT Details. Section Telecommunications Products - Detail. Date: October 8, 2014 Name of Product: BladeCenter HS23

ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE VEMP ECochG MLR P300

PC BASED AUDIOMETER GENERATING AUDIOGRAM TO ASSESS ACOUSTIC THRESHOLD

Speech Group, Media Laboratory

Improving Communication in Parkinson's Disease: One Voice, Many Listeners. This session was recorded on: Tuesday, June 4, 2013 at 1:00 PM ET.

What you re in for. Who are cochlear implants for? The bottom line. Speech processing schemes for

COMMUNICATION SCIENCES AND DISORDERS (CSD)

C H A N N E L S A N D B A N D S A C T I V E N O I S E C O N T R O L 2

Speech conveys not only linguistic content but. Vocal Emotion Recognition by Normal-Hearing Listeners and Cochlear Implant Users

AD629 The true hybrid

Solutions for better hearing. audifon innovative, creative, inspired

Strategies for Developing Speech, Language and Auditory Perception. Body Movements. The Hearing and Speech Foundation Maryville, TN

Transcription:

APPLICATIONS Voice Disorders Motor Speech Disorders Voice Typing Fluency Selected Articulation Training Hearing-Impaired Speech Professional Voice Accent Reduction and Second Language Learning

Importance of Speech Biofeedback Visi-Pitch IV extracts acoustic parameters (e.g., pitch, amplitude, and spectral characteristics) during speech/voice production and presents these in real time, providing clients with clear, intuitive visual displays. Using target vocalizations provided by a clinician, client attempts can be directly compared both graphically and with auditory playback. Monitoring important speech/voice behaviors with concrete visual displays helps clients reach therapy goals more easily. Overview Visi-Pitch IV is the latest version of the most widely used clinical instrumentation tool for speechlanguage pathologists. Encompassing the many features of previous generations of this acclaimed speech therapy tool, Visi-Pitch IV provides the latest, state-of-the-art, high-fidelity hardware for robust data acquisition and playback. As a clinical tool, Visi-Pitch IV offers clinicians an unmatched assortment of powerful methods to assess and treat their clients. Since its introduction in 1978, Visi-Pitch has become an indispensable tool in speech clinics worldwide. Its reputation has been earned by highly reliable performance and a versatile set of features. With eight standard modules, Visi-Pitch IV can be used with virtually every type of communication disorder in both assessment and therapy tasks. Critical speech and voice parameters are extracted and displayed in true real time to help clients achieve therapy goals with visual feedback. Protocoldriven assessment tasks provide clinicians with valuable objective data using parameters that are well documented in the professional literature. In addition to visual feedback and analysis of important speech/voice parameters, Visi- Pitch IV also provides multiple auditory feedback tools (based on the KayPENTAX Facilitator) that complement the visual feedback offered by other modules. Visi-Pitch IV helps clinicians objectively track patient progress and assists with the important goal of evidencebased clinical practice. Visi-Pitch IV analysis sophistication has been implemented without sacrificing ease of use for which the Visi-Pitch family has always been lauded. Clinicians new to the Visi-Pitch system are up and running in a matter of moments after system installation. Extensive Measurements of Speech and Voice Behavior To help objectify a client s baseline performance and subsequent change, Visi-Pitch IV extracts an extensive range of measurements relevant to speech and voice. In addition to fundamental frequency, amplitude, and spectral measurements, Visi-Pitch IV contains modules with tasks and concomitant parameters specific to disorders (e.g., dysphonia and motor speech problems). These parameters are displayed graphically and summarized quantitatively; both sets of information can be used in client reports. Real-Time Pitch allows clients to monitor pitch and amplitude as they speak. Speech productions can be compared both graphically (using split screen) and quantitatively. REAL-TIME PITCH A key module of Visi-Pitch IV is Real-Time Pitch, which displays fundamental frequency and relative intensity in real time. Stress, timing, intonational patterns, as well as target pitch and/or amplitude values during running speech can be seen as they are said by the client. Split screens allow target vocalizations to be compared to a client s attempt to imitate critical parameters (e.g., amplitude levels, speech rate, pitch range, etc.). The target and the client s attempt can then be compared

visually and quantitatively; high-fidelity audio playback allows the clinician and client to listen critically to important speech/voice behaviors. dysphonic voices as recommended by the National Center for Voice and Speech (NCVS). VOICE GAMES The Voice Games module provides animated graphics to represent the same parameters (i.e., pitch and amplitude) extracted in Real-Time Pitch. The games are particularly effective as therapy tasks for motivating children and rewarding good speech/voice behavior. Each game can be modified by the clinician to make a task more or less challenging, depending on the child s level of performance. Selected articulation therapy can be accomplished with the Real-Time Spectrogram module. The protocol above is for /r/ training. MOTOR SPEECH PROFILE Primarily an analysis tool, Motor Speech Profile assesses, in depth, the speech performance of patients with motor speech problems (i.e., dysarthria). Distinct tasks are elicited in systematic protocols (with message prompts) to help profile the patient s performance and identify potential motor speech problems; results of each task are quantified and graphed against a normative database. For example, a task for analyzing second formant transitions is sensitive in tracking vowel neutralization often observed in dysarthric patients; similarly, diadochokinetic rate and periodicity have been shown to be closely associated with articulatory agility. As with all Visi-Pitch IV parameters, the data can be included in a report summarizing patient performance. Games are used to motivate children in therapy with visually appealing graphics representing important speech/voice parameters. REAL-TIME SPECTROGRAM The spectrogram has been a benchmark analysis tool of speech signals for over a half-century because of its innovative, revealing, three-dimensional display. The real-time performance of Real-Time Spectrogram allows it to be used for selected articulation training (sample protocols are provided) and for voice typing of MSP parameters are sensitive to various aspects of dysarthric speech. This display analyzes second formant transitions which are frequently diminished in patients who neutralize vowels.

MULTI-DIMENSIONAL VOICE PROGRAM (MDVP) MDVP extracts objective quantitative values on sustained phonation, which are displayed graphically and numerically in comparison to built-in normative data. These are useful in profiling a patient s voice before and after surgery or voice therapy and complement stroboscopic, aerodynamic, and other methods used to assess the patient s voice. MDVP is the most frequently cited program in professional journals for analyzing sustained phonation because of its robustness and accuracy with both normal and dysphonic voices. Other programs calculate some of the MDVP parameters, but many of them do not hold up well when presented with dysphonic voices. MDVP has been tested and run on thousands of voice patients and has come to be viewed as a standard acoustic analysis method in voice clinics internationally. An optional CD-ROM of some 700 normal and pathological cases is available from KayPENTAX to help familiarize clinicians with acoustic profiles of various disorders. An array of auditory feedback tools is provided to help clients attain therapy goals. High-fidelity feedback is monitored through the headphones. AUDITORY FEEDBACK TOOLS Auditory Feedback Tools (AFT) is a highly useful module for critical listening feedback (using headphones) and various types of auditory feedback that have been found to be effective in achieving desired speech behaviors. A key premise of AFT is the seminal role of auditory feedback in speech therapy. Included are high-fidelity amplification, looped playback of selected speech tokens (e.g., word, phrase, or sentence level), Delayed Auditory Feedback (DAF), white-noise masking, speech-rate modification (e.g., prolonging an acquired utterance without altering its pitch on playback), and a metronome pacer. Most of these tools are a subset of features provided in the KayPENTAX Facilitator, which contains five modes of auditory feedback in a portable (wearable) instrument. FEATURES The MDVP graph provides a useful snapshot of the client s voice quality. Client performance (olive/red) is plotted against normative data (green) that is built into the software. WAVEFORM EDITOR This module is a convenient tool for speech waveform acquisition, editing, and playback. Selected portions of a speech sample can be edited and saved to disk. The Waveform Editor can also be used for dual-channel data acquisition. For example, a speech sample can be acquired with KayPENTAX s electroglottograph signal in the second channel. True real-time displays for visual feedback of critical speech/voice parameters Robust hardware for high-fidelity speech acquisition and playback Direct DAT input (without redigitization) Eight separate modules applicable across the spectrum of disorders Innovative graphic displays and quantitative measurements Auditory feedback tools (based on the KayPENTAX Facilitator) Vowel and sibilant training Single keystroke operation of commonly used protocols Games and graphic rewards to motivate children in therapy Numeric summaries of client performance for reports

SONA-MATCH Multiple innovative displays of the spectral patterns of sustained phonation (e.g., vowels and sibilants) are offered with the Sona-Match module. These are particularly useful for articulation training, second-language acquisition, and the singing voice. Sona-Match displays these spectral parameters in real time so that it can be used in therapy for visual feedback or as a teaching tool. Visi-Pitch IV Hardware The Visi-Pitch IV hardware environment meets most of the exacting demands of the NCVS with over 80 db dynamic range, two channels of input, excellent lownoise/high-fidelity input with an external hardware module for signal conditioning. The external hardware provides convenient access to connectors and controls for adjusting input levels during speech input. DAT players can be connected to the hardware for direct input without redigitizing the signal. A special Voice Range Profile (VRP) switch was designed into the Visi-Pitch IV external hardware module to provide absolute amplitude measurements. (VRP software is optional.) Additionally, Visi-Pitch IV is supplied with a quality microphone, headphones for critical listening, and a high-fidelity speaker. With the exception of the host computer (see requirements), Visi-Pitch IV is a complete hardware/ software system with matched components for excellent performance. The Sona-Match shows the formant patterns of the speaker. Two views can be used to enable the clinician to target desired patterns. Optional Programs for Visi-Pitch IV Additional programs are available for Visi-Pitch IV. These include the Voice Range Profile (VRP) program (Model 4326), the Real-Time EGG Analysis program (Model 5138), and an extensive database of some 700 disordered voice samples on the Disordered Voice Database and Program (Model 4337). Separate fliers on these programs are available from KayPENTAX. Sibilant training can be accomplished by placing a target (blue outline) of the client s best production followed by target matching while sustaining the desired sibilant (/s/ in this display). The red display is the client s production. Sona-Speech II for Sound Cards The software designed for Visi-Pitch IV is also available as a product called Sona-Speech II that works in conjunction with generic sound cards (e.g., SoundBlaster). Sona- Speech II is purchased without Visi-Pitch IV hardware and is, therefore, less expensive and may be ideal for the budget-minded clinician. Given the variability and specification limitation of most sound cards for speech acquisition, Sona-Speech II is generally not recommended for research applications. A separate brochure on Sona- Speech II is also available. MINIMUM HOST COMPUTER REQUIREMENTS FOR VISI-PITCH IV 500 MHz Pentium III PC 64 Mbytes RAM CD-ROM Windows 98SE/ME/2000/XP operating system S-VGA graphic adapter and monitor One available, full-size PCI slot

For more information on Visi-Pitch IV, please contact KayPENTAX or your local representative. World Leaders in Speech, Voice, and Swallowing Instrumentation KayPENTAX A Division of PENTAX Medical Company 2 Bridgewater Lane Lincoln Park, NJ 07035-1488 USA Tel: (800) 289-5297 (USA and Canada) (973) 628-6200 Fax: (973) 628-6363 E-mail: sales@kaypentax.com Web: www.kaypentax.com K05M1007