Muscle OxyGen monitor. The Science Behind Moxy

Similar documents
Oximeters. Hsiao-Lung Chan, Ph.D. Dept Electrical Engineering Chang Gung University, Taiwan

Consumer Near Infrared Spectroscopy as a Training and Recovery Tool. Jon Tarkington

Oximeters. Hsiao-Lung Chan, Ph.D. Dept Electrical Engineering Chang Gung University, Taiwan

Monitoring Tumor Therapy

How Does Pulse Oximetry Work? SpO2 Sensors Absorption at the Sensor Site Oxyhemoglobin Dissociation Curve

Biomedical Instrumentation D. The Photoplethysmogram

Introduction. Device Description. Dual-Band Spectral Output

Use of the Free Electron Laser for the Noninvasive Determination of Retinal Oxyhemoglobin Saturation by Near Infrared Reflectance Spectrophotometry

Optical Sensor System for Hemoglobin Measurement

Measuring Heart Rate and Blood Oxygen Levels for Portable and Wearable Devices

Research Journal of Pharmaceutical, Biological and Chemical Sciences

Finger Pulse Oximeter. User Manual. Einstein Associates LLC Stafford Centre Drive Suite B Stafford, TX

Zacurate CMS 500DL. Finger Pulse Oximeter. User Manual

Oxygen Saturation Monitors & Pulse Oximetry. D. J. McMahon rev cewood

Clinically Available Optical Topography System

ALCO Regulations. Protocol pg. 47

ISSN: [Cortes* et al., 7(3): March, 2018] Impact Factor: 5.164

Light is wearable Health Monitoring and Fitness Tracking Light is OSRAM

Intrinsic Signal Optical Imaging

Pulse oximetry revisited. Dr Liesel Bösenberg Specialist Physician and Fellow in Critical Care Kalafong Hospital University of Pretoria

Design and Development of Non-Invasive Prototype to Measure Pulse Rate, Blood Glucose and Oxygen Saturation Level in Arterial Blood

Smart Probe for Uric Acid Detection

CIE Biology GCSE. 9: Transport in animals. Notes.

Dr. D.McG.Clarkson Determining the Accuracy of SpO2 Values

Technologies and Methods for Visualizing the Retina

#6 - Cardiovascular III Heart Sounds, Pulse Rate, Hemoglobin Saturation, and Blood Pressure

Development of an Optical Sensor Based System for Detection and Monitoring of Hemoglobin in Blood

Estimation of protein using standard curve & Biochemistry analyzer. Experiment 1 & 2 BBT 314 ACh

OpenStax-CNX module: m Transport of Gases. OpenStax College. Abstract

Saturday Physics Honors presents. Professor Enrico Gratton, Looking Into the Brain with Lasers. (With some demonstrations)

Laser Effects on Skin Melanin

In reality the PDT mechanism requires that three things be together in the body at the same time. These three things are oxygen, chromophore

Psy393: Cognitive Neuroscience. Prof. Anderson Department of Psychology Week 3

Pulse Oximeter Accuracy Study

Competitive Intelligence Report Technology & Patents

The Cardiovascular System

The circulatory system transports blood to deliver important substances, such as oxygen, to cells and to remove wastes, such as carbon dioxide.

Multilayer Gafchromic film detectors for breast skin dose determination in vivo

BLOOD GLUCOSE LEVEL MONITORING BY NONINVASIVE METHOD USING NEAR INFRA RED SENSOR

Circulatory, Respiratory, and Excretory Systems

ORIGINAL RESEARCH. Effect of road traffic accident contaminants on pulse oximetry among normoxaemic volunteers

Photoacoustic Imaging and Therapy in Biomedicine. Nicholas Tobey and Grace Yook. Optical Engineering. Dr. Kasra Daneshvar

Noninvasive Blood Glucose Analysis using Near Infrared Absorption Spectroscopy. Abstract

Non Invasive methods of Hemoglobin

A. Incorrect! The left ventricle receives oxygenated blood from the lungs via the left atrium.

Four-Wavelength Near-Infrared Imaging of Abdominal Aorta Blood Flow under Surgical Occlusion

PHOTOTHERAPY: WHAT DO WE KNOW AND HOW DOES IT WORK? Suite 3/36 O'Riordan Street Alexandria, Sydney NSW Australia

Pulse Oximeter Accuracy Study

BSX Answers to DCR Questions:

Pancreas: digestive enzymes Liver: bile-helps to digest fat, stored in gallblader; breaks down toxins, makes some parts of blood

Permanent City Research Online URL:

CH.2 LIGHT AS A WAVE

The Body s Transport System (pp )

NPTEL NPTEL ONLINE COURSE. NPTEL Online Certification Course (NOC) NPTEL. Theory and Practice of Non Destructive Testing

Chapter 27 -The Heart & Blood Vessels

Chandra Ramamoorthy MBBS; FRCA (UK) Professor of Anesthesiology, Stanford University. Director of Pediatric Cardiac Anesthesiology

The Circulatory System

Unit 6.1 Test Review THE NERVOUS, INTEGUMENTARY, CIRCULATORY, AND RESPIRATORY SYSTEMS

Introduction. Cell Biology OLM

Bodies and Systems. What is your body made of?

7.L.1.4 Circulatory System Guided Study Notes. Circulation

CORRELATION BETWEEN MEASUREMENT OF ARTERIAL SA TURA TION BY PULSE OXIMETRY AND BY HEMOXYMETER IN CHILDREN WITH CONGENITAL HEART DISEASE

Appendix E Choose the sign or symptom that best indicates severe respiratory distress.

Journal of Faculty of Engineering & Technology DESIGN AND IMPLEMENTATION OF A WEARABLE HEALTH DEVICE

Chapter 12 - Vital_Signs_and_Monitoring_Devices

EXPOSURE SCHEDULES FOR SUNTANNING PRODUCTS

Glossary: The Cardiovascular System

Mammalian Transport and The Heart

Non Invasive Estimation of Blood Glucose using Near Infra red Spectroscopy and Double Regression Analysis

Hierarchy of Biological Organization

TRANSPORTATION AND CIRCULATION THE CIRCULATORY SYSTEM

OB16 Demonstrate the effect of exercise and rest on pulse and breathing rate and appreciate that a balance of each promotes good health

Unit 23.1: The Circulatory System

Warm Up- Monday -AND- Setup Cornell Notes.

Cardiovascular System

Aerobic and Anaerobic Respiration Revision 2

Chapter 27 The Heart and Blood Vessels

Noninvasive Detection of Bilirubin in Discrete Vessels

Pulse oximetry in the accident and emergency department

Physiology of the Circulatory System modified from

Internal Calibration System of Thermo Scientific Varioskan Flash with Improved Sensitivity, Accuracy and Dynamic Range

Human Circulation and Respiration Chapter 38

Circulatory System. Circulatory System

In vivo Infrared Spectroscopy

37 1 The Circulatory System

PART A: MULTIPLE CHOICE (100 questions 65% of exam mark)

SUBJECT INFORMATION AND CONSENT FORM

Application of near-infrared spectroscopy for discrimination of mental workloads

May 2003: Hemoglobin Red Blood, Blue Blood Use and Abuse of Hemoglobin

Development of a New Rehabilitation System Based on a Brain-Computer Interface Using Near-Infrared Spectroscopy

The diagram below shows the parts of the body that digest and absorb food.

Chromatography Vacuum Ultraviolet Spectroscopy

TOPIC 6: HUMAN HEALTH AND PHYSIOLOGY

Design a system of measurement of heart rate, oxygen saturation in blood and body temperature with non-invasive method

Non-invasive Hemoglobin Measurement for Anemia Diagnosis

Am I Getting Anywhere? Physics of Blood Flow-Velocity. Student Data Page, Activity 3C

Oxygen Level Measurement Techniques: Pulse Oximetry

Circulation and Respiration

CEREBRAL OXIMETRY IN INFANTS WITH HIE DAPHNA YASOVA BARBEAU, MD FN3 MEETING 2018

Diffuse reflectance spectral detection of stress-induced stomach ulcers in animal models

Transcription:

Muscle OxyGen monitor The Science Behind Moxy

How Does Moxy Monitor Work? Moxy Monitor works by shining near-infrared light onto the skin and detecting some of the light after it has travelled into the muscle tissue and returned to the surface. Light travels through tissue especially in the Red and Near-Infrared region of the spectrum. As it moves through the tissue, light scatters. This scattering is caused primarily by the differences in the index of refraction inside of the cells. This is why your hand glows red when you hold it over a flashlight. The visible light spectrum ranges from about 380 nm on the violet end to about 750 nm on the red end. Moxy Monitor utilizes four separate light sources that cover the wavelength range from 630 to 850 nm. There are two reasons why this wavelength region is useful for measuring muscle oxygenation. First, light can travel far enough in tissue to get down to the muscle and back out. Second, oxygenated and deoxygenated hemoglobin have different absorbance spectra in this region. One could say they are a different color, recognizing that such a term usually applies to human perception of visible light. The absorption spectra of oxygenated and deoxygenated hemoglobin. 1 moxymonitor.com

Chromophores are groups of atoms within a molecule that absorb light differently at different wavelengths. Oxy- and Deoxyhemoglobin are chromophores. It is possible to make quantitative measurements of the concentrations of chromophores using the Beer-Lambert Law. A beam of light is passed through a sample to be measured. The amount of light that is absorbed is the logarithm of the starting intensity divided by the intensity that exits the sample. Epsilon is the molar absorptivity which is a property of the chromophore and is available in published literature. l is the path length that the light travels through the sample. By measuring the light absorbed by the sample with several wavelengths of light and using some mathematical analysis such as partial least squares, chemists routinely measure the concentrations of mixtures of chromophores. Moxy also uses the Beer-Lambert Law for its measurements. However, this metric poses a significant difficulty. Light doesn t pass straight through tissue, making it difficult to discern path length. In fact, light travels many different path lengths on its way from the emitter to the detector. This is further complicated by the fact that the path length shows variability at different wavelengths and in varying tissue types such as skin, fat, and muscle. Light is emitted into the tissue at one location and then is detected at two locations, 12.5 and 25 mm from the emitter. This schematic illustrates the emitter and one detector, however it only shows the light that reached the detector. Light scatters in all directions, and the vast majority of it is lost. As little as one-millionth of the emitted light actually reaches a detector. moxymonitor.com 2

The Moxy uses four Light Emitting Diodes (LEDs) for its light emitter. The four LEDs fire in rapid sequence, and the light intensity is recorded simultaneously at each of the two detectors. Over the years, researchers have developed ways to overcome the problem of unknown path length in order to measure chromophore concentrations in tissue. Very sophisticated instruments have been built to measure the time of flight of a light pulse through tissue. However, timing how long it takes light to travel a couple of inches requires a very expensive stopwatch. A less-sophisticated technique attempts to calibrate on human subjects by inducing high and low oxygenation states and correlating measured light reflection with the oxygenation measured from blood draws. This approach has several problems. The optical measurement occurs in the capillaries, but the blood draw comes from the veins, where the oxygenation state is different. Also, this method can only practically cover a small portion of the variability in tissue such as skin color and fat layer thickness. Another technique developed involves a tissue phantom. Human subjects are replaced with an apparatus that mimics the optical properties of human tissue. Typically, the phantoms have limited similarity to human tissue. To overcome the path length issue, Moxy has developed a proprietary new technique. The calibration of the Moxy device is based on a mathematical model of how light propagates through tissue. This model is able to account for a wide range of variations in tissues. It is perplexingly complex and tedious to implement, but the payoff is worth the effort. This algorithm allows us to eliminate the expensive optical components required by certain techniques, and remove the guesswork of others, allowing for accurate readings on muscle over a wide range of skin and fat-layer conditions. Moxy measures the ratio of the oxyhemoglobin concentration to the total hemoglobin concentration in the muscle and reports it as a percentage, which is SmO 2. 3 moxymonitor.com

What is Smo 2? SmO 2 stands for muscle oxygen saturation. It is the percentage of hemoglobin that is carrying oxygen in muscle tissue. Hemoglobin is the molecule in red blood cells that actually carries oxygen from the lungs to where it is needed in the body. Hemoglobin responds to chemical signals to drop off oxygen where it is needed. Hemoglobin s most common states are oxy and de-oxy. The measurement of SmO 2 takes place in the capillaries of the muscle. This is where the oxygen is being consumed. SmO 2 can be thought of as a measure of the balance between demand increases, but the heart hasn t had a chance to speed up, and the blood vessels in the muscle haven t dilated. The SmO 2 drops quickly in these conditions. As you warm up, your heart rate increases, and the blood vessels in the muscle dilate to 2 levels. When you stop exercising, the demand for oxygen suddenly falls, but the heart rate is still elevated and blood vessels dilated. At this time, a rapid increase in SmO 2 is observed. Generally, higher levels of exertion in the muscle lead to lower SmO 2. The SmO 2 value is also affected by other factors such as the hemoglobin dissociation curve shifting and other chemical and neurological factors. moxymonitor.com 4

How is This Different than a Pulse Oximeter? hospital patients. Much like Moxy, it works by measuring the color of blood. However, the pulse oximeter keys in on pulsations caused by the arteries expanding and contracting with each heartbeat. In this way, it measures only arterial blood. Essentially no oxygen is consumed in the arteries from the time blood leaves the lungs until it reaches the earlobe readings that do not change when you exercise. Generally, the lungs are able to oxygenate the arterial blood to 85% to 100% saturation. However, lower arterial saturation is possible at high exercise intensity, at altitude or when the blood chemistry shifts the hemoglobin dissociation curve to the right. Pulse oximeters are really used to make sure you re still breathing properly. Pulse oximeters typically use two wavelengths of light emitter and have one detector. of light emitter, and measures light with two detectors. This novel approach allows Moxy to measure blood in the capillaries rather than in the arteries. The Moxy Muscle Oxygen Monitor system utilizes a complex algorithm to measure the oxygen saturation deep within exercising muscle tissue. Moxy measures SmO 2 non-invasively and in real-time. Moxy is totally portable, so an athlete can use it anywhere. Moxy provides accurate SmO 2 data that is highly useful in guiding exertion levels during exercise to keep muscles in the desired metabolic state. 5 moxymonitor.com