Laparoscopic Repair of Inguinal Hernia with Biomimetic Matrix

Similar documents
MOVE BEYOND. to new hope for enterocutaneous fistulas. Enterocutaneous Fistula Repair

34 yo M presented in ER of KCH at 7/06/10 Painful lump lt groin + vomiting Pain started 2 hrs before presentation. PMH known left inguinal hernia PSH

II.- PLUG. NAME of the products. Premilene Mesh Plug MANUFACTURER. B Braun DESCRIPTION. Polypropylene mesh for plug technique

Meshes. Meshes. Non-absorbable meshes. Absorbable meshes

3/21/2011. Advances in laparoscopic ventral hernia repair. Laparoscopic approach well-suited for simple hernias:

International Journal of Science and Research (IJSR) ISSN (Online): Index Copernicus Value (2013): 6.14 Impact Factor (2013): 4.

7/2/2015. Incidence. *Mudge M et al, Br. J. Surg, 1985, 72:70-71

Hybrid mesh for sports hernia repair

JMSCR Vol. 03 Issue 08 Page August 2015

Comparison of Transabdominal Preperitoneal and Total Extra Peritoneal: A Prospective Study

Transabdominal pre peritoneal (TAPP) vs totally extraperitoneal (TEP) laparoscopic techniques for inguinal hernia repair

Designed to help advance patient outcomes and ease of use

Technique Guide. Bard MK Hernia Repair. Featuring Modified Onflex Mesh SOFT TISSUE REPAIR. Anterior Approach to a Preperitoneal Inguinal Hernia Repair

Ventralex ST Hernia Patch featuring Sepra Technology

ABSITE Review: Hernias

Hernias Umbilical Hernia When to See a Surgeon? What Are Symptoms of an Umbilical Hernia? How is Repair Performed?

Tissue-Separating Mesh A Comparative Guide

VALUE ANALYSIS COMMITTEE PRODUCT INFORMATION KIT

ORIGINAL ARTICLE. Total Extraperitoneal Laparoscopic Inguinal Hernia Repair Without Mesh Fixation

B. Braun Mesh Range It s All about Prevention. Experts in Abdominal Wall Health. Hernia Repair

Laparoscopic Hernia Repair, Indications, Superiority and Outcome

NiTiNol Hernia Device Stability in Inguinal Hernioplasty Without Fixation

First Transumbilical Transabdominal Preperitoneal Inguinal Hernia Repair in the Middle East

Biodesign E NTEROCUTANEOUS FISTULA PLUG

Ultrapro Hernia System Bi Layer Dr Cosmas Gora T SpB-KBD. dffdfdfxxgfxgfxgffxgxgxg

Repair of inguinal hernia utilizing external oblique muscle sheath as posterior wall strengthening and placing spermatic cord subcutaneously

Inguinal and Femoral Hernias. August 10, 2016 Basic Science Lecture Department of Surgery University of Tennessee Health Science Center

STOMA SITING & PARASTOMAL HERNIA MANAGEMENT

Colorectal procedure guide

Objectives. Hesselbach s Triangle 11/30/2009. Myopectineal Orifice of Fruchaud. Hernias: Who, What, When, Where, Why?

Early View Article: Online published version of an accepted article before publication in the final form.

Glue for mesh fixation in laparoscopic ventral hernia repair. An experimental comparison with conventional fixation.

Evidence Summary. Ethicon Hernia Portfolio. Better surgery for a better world

CorMatrix ECM Bioscaffold

Perhaps the most controversial of new laparoscopic operations is the repair of the inguinal hernia. The

Hybrid Laparoscopic and Anterior Approach for Postsurgical Inguinal Hernia After Iliofemoral Arterial Bypass

Case Report. XCM Biologic Tissue Matrix. Components separation using sandwich technique for reconstruction of abdominal wall defect.

1. Introduction. 2. Material and methods Methodology

TiLENE. Plug Set Titanized Polymers. Surgical Technique

LAPAROSCOPIC TOTAL EXTRAPERITONEAL INGUINAL HERNIA REPAIR: A STUDY AT RAWALPINDI MEDICAL COLLEGE AND ALLIED TEACHING HOSPITALS ABSTRACT

Needlescopic Surgery Versus Single-port Laparoscopy for Inguinal Hernia

Mædica - a Journal of Clinical Medicine STATE-OF-THE-ART. , Danut VASILE. University of Medicine and Pharmacy Carol Davila Bucharest, Romania

Setting The setting was a hospital. The economic study was carried out in Parma, Italy.

LAPAROSCOPIC HERNIA REPAIR

CODING AND PRACTICE MANAGEMENT CORNER

A Randomised Control Study on Neurosensory Outcomes of lioingunal Neurectomy in Lichtenstein s Hernia Repair

The use of peritoneal flaps in the repair of large incisional hernia

Comparison of Laparoscopic vs Open Modified Shouldice Technique in Inguinal Hernia Repair. Thomas Nicholson, MD, V. Tiruchelvam, MD METHODS

Sexual function after Stoppa hernia repair in patients with bilateral inguinal hernia

Laparoscopic Versus Conventional Open Surgery for the Treatment of Bilateral Inguinal Hernias

OptiFix Absorbable Fixation System

DGAFMS MEDICAL MEMORANDUM ON INGUINAL HERNIA AND THEIR DISPOSAL. 2. Three Primary causes can be distinguished in the etiology of Hernia.

Hernia Surgery in Adults

Technical points of the laparoscopic transabdominal preperitoneal (TAPP) approach in inguinal hernia repair

A Comparative Study between Onlay and Pre Peritoneal Mesh Repair in Management of Ventral Hernias

Farah S, Kiyingi A, Leinkram C. The Melbourne Hernia Clinic Masada Hospital 26 Balaclava Road St Kilda East Victoria, Australia 3168.

SDRP JOURNAL OF ANESTHESIA & SURGERY

JMSCR Vol 05 Issue 03 Page March 2017

4D Mesh Flat et 4D Mesh Anatomique

The Feasibility of Laparoscopic Total Extraperitoneal (TEP) Herniorrhaphy after Previous Lower Abdominal Surgery

The Strong New Choice MILLION. From A Provider. You Already Know

C. Nikkolo, T. Vaasna, M. Murruste, H. Seepter, Ü. Kirsimägi, U. Lepner

Assessment and comparison of laparoscopic hernia repair versus open hernia: a non-randomized study

Hernia Repair: Measures of Success and Perioperative Considerations

A comparative study of inguinal hernia repair: Shouldice versus Lichtenstein repair

Move beyond to Biodesign.

Suture Versus Tack Fixation of Mesh in Laparoscopic Umbilical Hernia Repair

Crural Buttressing: Why, When, and with What

Short-term effect of laparoscopic assisted total extraperitoneal repair with small-incision for large inguinal hernia in adults.

Hernia surgery in adults

Pilot study of selective fixation of mesh in laparoscopic extra-peritoneal inguinal hernia repair (TEP)

Contents. Part I Essentials of Inguinal Hernia. Part II Techniques for Inguinal Hernia Repair

COMPARISON OF OUTCOMES (EARLY AND LATE) FOLLOWING OPEN AND LAPAROSCOPIC REPAIR OF INGUINAL HERNIAS: AN EXPERIENCE OF A SINGLE SURGICAL UNIT

JMSCR Vol 04 Issue 04 Page April 2016

Hernia. emoryhealthcare.org

botiss dental bone & tissue regeneration biomaterials collacone max Innovative composite matrix socket preservation form-fitting resorbable composite

botiss biomaterials bone & tissue regeneration collacone max Innovative composite matrix socket preservation form-fitting resorbable composite

JMSCR Vol 04 Issue 09 Page September 2016

Research Article Use and Indications of Human Acellular Dermis in Ventral Hernia Repair at a Community Hospital

Open Tension-Free Mesh Repair for Adult Inguinal Hernia: Eight Years of Experience in a Community Hospital

Journal of Innovations in Pharmaceuticals and Biological Sciences

STUDY OF PROLENE HERNIA MESH SYSTEM IN MANAGEMENT OF PRIMARY INGUINAL HERNIA REPAIR Vishal Nandagawali 1, Amit Bellurkar 2

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE GUIDANCE EXECUTIVE (GE) Review of TA83 Laparoscopic surgery for inguinal hernia repair

Early Outcome Of Inguinal Hernia Repair Using Ultrapro Mesh In University Of Calabar Teaching Hospital, Nigeria

A prospective comparison of ambulatory endoscopic totally extraperitoneal inguinal hernioplasty versus open mesh hernioplasty

Life Science Journal 2017;14(1) Single port versus multiport laparoscopic trans abdominal preperitoneal hernia repair.

From the Unit of General and Geriatric Surgery, School of Medicine, Department of Surgery, Second University of Naples, Italy

J of Evolution of Med and Dent Sci/ eissn , pissn / Vol. 4/ Issue 77/ Sept 24, 2015 Page 13279

The lateral incisional hernia: anatomical considerations for a standardized retromuscular sublay repair

Single-Port Onlay Mesh Repair of Recurrent Inguinal Hernias after Failed Anterior and Laparoscopic Repairs

Trans Abdominal Pre-Peritoneal (TAPP) mesh for Inguinal Hernia Repair with External Fixation [Abdelhamid Technique], Outcome Assessment

ARTIFICIAL MESH REPAIR FOR TREATMENT OF PELVIC ORGAN PROLAPSE

Cure of inguinal hernias with large preperitoneal prosthesis: Experience of 2,312 cases

Title at a Single Institution. Issue Date Right.

Laparoscopic ventral hernia repair: extraperitoneal repair

Setting The study setting was tertiary care. The economic study was carried out in the USA.

The Preperitoneal Inguinal Hernia Prosthetic Repair: Indications and Technical Notes

Pelvic Prolapse. A Patient Guide to Pelvic Floor Reconstruction

Hernia repair: the search for ideal meshes

Fish Skin Grafts Promote Superior Cell Ingrowth Compared to Amnion Allografts, Human Cadaver Skin and Mammalian Extracellular Matrix (ECM)

Transcription:

SCIENTIFIC PAPER Laparoscopic Repair of Inguinal Hernia with Biomimetic Matrix Arthur Fine, MD ABSTRACT Background and Objectives: Materials utilized for the repair of hernias fall into 2 broad categories, synthetics and biologics. Each has its merits and drawbacks. The synthetics have a permanent, inherent strength but are associated with some incidence of chronic pain. The biologics rely on variable tissue regeneration to give strength to the repair, limiting their use to specific situations. However, thanks to their transient presence and tissue ingrowth, the biologics do not result in a significant incidence of chronic pain. We studied the use of a biomimetic (REVIVE, Biomerix Corporation, Fremont, CA) in this setting in an attempt to obviate the disadvantages of each material. Methods: Fourteen patients underwent laparoscopic repair by totally extraperitoneal and transabdominal preperitoneal techniques of 16 inguinal hernias. Follow-up was as long as 19 mo, and 8 patients were followed for 12 mo. There were no recurrences and a 5% incidence of functionally insignificant discomfort. Results: REVIVE is shown in histology and in vivo to demonstrate regeneration and tissue ingrowth into the polycarbonate/polyuria matrix similar to that in the biologics rather than scarring or encapsulation. There were no recurrences, indicating its strength and resilience as a permanent repair similar to that in the synthetics. Conclusion: This is proof of the concept that a biomimetic may bridge the gap between the biologics and synthetics and may be able to be utilized on a regular basis with the benefits of both materials and without their drawbacks. Key Words: Revive, biomimetic, synthetics, biologics, hernia. Department of Surgery, Jefferson Regional Medical Center, Pittsburgh, PA, USA. Address correspondence to: Arthur Fine, MD, Jefferson Regional Medical Center, 575 Coal Valley Road, Pittsburgh, PA 15236, USA. Phone: (412) 469-7035, Fax: (412) 469-7037, E-mail: arthur_fine@msn.com DOI: 10.4293/108680812X13462882737050 2012 by JSLS, Journal of the Society of Laparoendoscopic Surgeons. Published by the Society of Laparoendoscopic Surgeons, Inc. INTRODUCTION The repair of an inguinal hernia is the most commonly performed abdominal general surgery procedure. 1 Over time, many aspects of the surgical technique to repair inguinal hernias have evolved, namely the approach and type of mesh material used to reinforce the repair. Surgical technique has progressed from a primary repair with sutures to the tension-free Lichtenstein repair. In recent years, laparoscopic surgery has emerged as a viable approach, further advancing the treatment of inguinal hernia. Today, the types of mesh material available to surgeons are numerous, with offerings ranging from synthetics like polypropylene or polyester to biologics derived from human and animal tissue. While the type of mesh material has evolved, there is no gold standard, and the best mesh material for use in the repair of an inguinal hernia remains a source of debate amongst surgeons. Central to a physician s decision as to which mesh material to use is the consideration given to limiting chronic pain. The incidence of chronic pain in inguinal hernia repairs, a clinical outcome across all types of surgical approaches, ranges from 10% to 15%. 2 It is believed that the type of mesh material used to reinforce an inguinal hernia repair plays a role in chronic pain. Materials used in the repair of hernias fall into 2 broad categories, synthetics and biologics, each with its own advantages and disadvantages. Synthetics have a permanent degree of inherent strength but are believed to cause more chronic pain that results from the formation of scar plate and unorganized tissue healing response. 3,4 Physicians looking for a more natural healing solution that is not a permanent implant have moved toward the use of biologics, in favor of a remodeling biomaterial that leaves the patient essentially de novo. Biologics facilitate a more natural pattern of host tissue infiltration. However, their use is limited, because they are costly, they have an inherent inability to bridge defects, and in some instances they may cause eventration and reherniation. 5 Despite biologics promise to restore the body s natural structure, the failure of these materials to provide a reliable repair across all types of hernias (i.e., direct and bridging repairs of ventral hernias) has prompted some surgeons to suggest that with improvements in tissue engineering, mate- 564

rials can be developed to eliminate these deficiencies, resulting in biomaterials that will become the standard of care in hernia repairs 10 y from now. 6 This study evaluates REVIVE (Biomerix Corporation, Fremont, CA) surgical mesh, which consists of a novel biomaterial that combines the favorable properties of a biologic to support robust tissue ingrowth with the durability of a synthetic. The permanent structure of the mesh allows it to bridge defects, creating a strong mechanical repair, while its unique microarchitecture supports tissue ingrowth and formation (Figure 1). METHODS In a single-arm evaluation study for the repair of inguinal hernias, 14 patients underwent laparoscopic repair with REVIVE. A total of 16 inguinal hernias were treated across the 14 patients. The only criterion for inclusion was the patient s suitability to undergo a laparoscopic inguinal hernia repair under general anesthesia. All procedures were elective and were performed with general anesthesia at an outpatient surgery center. Patients were informed of the intended use of an FDA-approved mesh, as well as the relative merits of the various materials that could be used. A preoperative antibiotic was administered to each patient: 2g of Ancef, or if the patient was allergic to penicillin, 900 mg of clindamycin. Repairs were accomplished laparoscopically using either a totally extraperitoneal or a transabdominal preperitoneal approach. A preshaped section of REVIVE mesh was placed from the midline of the pubis to the iliac Figure 1. Scanning electron microscope image of the Revive matrix. crest. REVIVE is composed of a lightweight polypropylene mesh with 2 thin layers of a proprietary biomaterial bonded to both sides and designed to facilitate biointegration. The biomaterial is a nondegradable, reticulated polycarbonate-polyurethane-urea consisting of a 3-dimensional, open-cell, macroporous structure that selectively adsorbs plasma and extracellular matrix proteins, thus paving the way for cells to migrate, proliferate, attach, and regenerate new tissue. For totally extraperitoneal (TEP) repairs (Figure 2), fibrin glue (Tisseel, Baxter, Deerfield, IL) was used to fixate the mesh, while titanium tacks (ProTack, Covidien, Mansfield, MA) were used for (transabdominal preperitoneal) TAPP procedures (Figure 3). A Foley catheter was placed in the patients undergoing the TAPP repair but not in patients undergoing the TEP repair. Postoperative data included length of stay, infection, pain, and functional status. All patients were discharged the same day and re-evaluated at 2 wk. Outcomes were based on recurrence rates in the patients who were at least 12 mo out from their repair. Additionally, each patient was asked to fill out a simple questionnaire to evaluate the impact of any long-term pain. On the questionnaire, pain was characterized as either no pain, occasional twinges, or chronic daily pain that affects activities. Seven patients were followed up for an average period of 25 mo (range, 18 to 33). Of the remaining patients, the follow-up period averaged 6 mo (range, 6 to 7). RESULTS Fourteen patients with a total of 16 inguinal hernia repairs were implanted with REVIVE. Of the 14 patients, half were followed for at least 18 mo, with an average follow-up of 25 mo. The average age of these 7 patients was 59 y, and the group consisted of 1 female and 6 males. These 7 patients had a total of 8 hernias, all of them indirect in nature. Across all 14 patients, there were no (0%) hernia recurrences. Using a functional pain scale of no pain, pain with no limitations on activity, and pain that limits on activity, only 1 of 14 patients (93% No Pain, 7% Mild Pain) reported pain with limitations on activity at 6 mo. The one patient reported occasional pain that, in his words, resolved with activity and completely resolved at 24 mo. He had undergone a totally extraperitoneal repair with fibrin glue fixation, typical of many synthetics. 565

Laparoscopic Repair of Inguinal Hernia with Biomimetic Matrix, Fine A. Figure 2. The Revive matrix in a right inguinal Totally Extraperitoneal repair with fibrin tissue sealant fixation. Clockwise from the upper left; the Revive matrix, cut to shape, the reduced hernia sac held on the peritoneal side of the matrix repair, application of fibrin tissue sealant and, the matrix repair in position. Figure 3. A Transabdominal Preperitonel repair. On the left, the matrix in the preperitoneum. On the right, the repair, reperitonealized. 566

DISCUSSION Since the introduction of the Bassini technique, characterized as a tension repair, numerous surgical methods have been developed and utilized in the repair of inguinal hernias. Most notable is the Lichtenstein tension-free open repair involving the placement of a synthetic mesh, such as a polypropylene, to strengthen the inguinal region. In the United States, as today s standard of care for the treatment of inguinal hernias, the Lichtenstein repair has resulted in low recurrence rates. However, one aspect of inguinal hernia surgeries that has not changed is the rate of chronic pain consistently reported across various surgical techniques and types of materials used as mesh reinforcement. 7 9 To better understand the role of mesh and its potential influence on pain, it is important to understand the evolution of mesh materials and the perceived advantages and disadvantages of the various mesh materials available today. For the past 20 y, advanced laparoscopic surgery techniques have been utilized for the repair of hernias, such as the use of plugs, intraperitoneal onlay patches, and totally extraperitoneal and transabdominal preperitoneal repairs. In laparoscopic repairs, surgeons have used polypropylene meshes and more recently polyester weaves. Initially, surgeons embraced the use of synthetic meshes that were heavy and bulky. However, over time, studies of heavyweight meshes have shown that these meshes can often result in the formation of a scar plate rather than production of healthy tissue incorporation, which may lead to more chronic pain. 10 Although, synthetic meshes provide a durable repair at a low cost, the long-term potential for chronic pain is a significant drawback. The introduction of biologics has provided surgeons with a permanent repair for the treatment of inguinal hernias without leaving a permanent implant. Biologics offer initial strength to the repair and are equivalent in strength to a synthetic prosthesis in the early stages of healing, and over time they are remodeled by the body creating a more natural healing response that may decrease the risk of long-term pain. However, the limitations of biologics make them a less desirable alternative for all inguinal hernia repairs. The high cost associated with biologics also makes them a less attractive option. Additionally, the lack of reliable ingrowth across the entire span of the matrix results in a failure to develop a permanent structure and maintain a durable repair, leading to eventration and in some cases reherniation, known as an inability to bridge the defect in large ventral and direct inguinal hernias. There have, however, been few trials comparing the benefits of biologics and synthetics in this role. 1 Manufacturers have tried to develop newer, more flexible polypropylene and polyester materials, with the promise of incorporation rather than encapsulation. The ideal material for the repair of inguinal hernias should result in a low rate of recurrence. Secondly, it should be well tolerated, causing little pain or limitation on a patient s activities. Lastly, it should be inexpensive. We believe the REVIVE surgical mesh demonstrates these ideal biomaterial attributes, making it a compelling alternative to existing synthetics and biologic mesh offerings. REVIVE surgical mesh consists of an open-cell, 3-dimensional, interconnecting macroporous structure designed to play a role similar to the extracellular matrix. Preclinical research shows that REVIVE leads to excellent tissue regeneration and tissue ingrowth into the polycarbonate polyurethane-urea, as opposed to scarring or encapsulation typically seen with other synthetic alternatives. Its permanent structure offers the mechanical support of synthetics, while being highly permeable (average 380, Darcy s permeability constant). This makes it an ideal scaffold to support predictable organized fibrovascular tissue ingrowth. Further, other studies have shown that at 6 mo REVIVE demonstrates minimal shrinkage, a demonstrated trait of synthetics that can result in recurrence and pain. Early outcomes of laparoscopic inguinal hernia repair utilizing REVIVE were promising. Despite the small sample size, we believe the results of this study are a directional indication of REVIVE s clinical performance and, while not a large enough sample for a definitive conclusion, does represent proof of concept justifying further evaluation. The absence of recurrences indicates its strength and resilience as a permanent repair similar to other synthetics. Overall, a favorable outcome was reported for chronic pain with this sample population. At 6 mo, only 1 out of 14 patients (7%) reported pain that resolved with activity. While the precise incidence of chronic pain after hernia repair is unknown, select studies suggests 20% of patients are affected, and an estimated 12% report the intensity of pain impairs some aspects of their daily activity. 12 The low rate of pain reported in this study calls for broader analysis to study the benefits of REVIVE and how it could lead to a reduction in pain following an inguinal hernia repair. CONCLUSION These surgical cases provide a proof of concept that a REVIVE mesh may be utilized on a regular basis, leverag- 567

Laparoscopic Repair of Inguinal Hernia with Biomimetic Matrix, Fine A. ing the benefits associated with synthetics and biologics without their inherent drawbacks. References: 1. Laparoscopic v. open repair of groin hernia: a randomized comparison. The MRC Laparoscopic Hernia Trial Group. Lancet. 1999;354(9174):185 190. 2. Fine AP. Laparoscopic repair of inguinal hernia using Surgisis mesh and fibrin sealant, JSLS. 2006;10(4):461 465. 3. Schumpelick V, Fitzgibbons R. Hernia Repair Sequelae. 1st Edition, NY, NY: Springer; 2010. 4. Cobb WS, Kercher KW, Heniford BT. The argument for lightweight polypropylene mesh in hernia repair. Surg Innov. 2005;12(1):63 69. 5. Blatnik J, Jin J, Rosen M. Abdominal hernia repair with bridging acellular dermal matrix an expensive hernia sac. Am J Surg. 2008;196(1):47 50. 6. The Use of Biologic Materials for Hernia Repair. General Surgery News. March 2008;. 35(3) 7. Dennis R, O Riordan D. Risk factors for chronic pain after inguinal hernia repair. Ann R Coll Surg Engl. 2007;89(3):218 220. 8. Leardi S. Postoperative pain as complication of hernia surgical repair with mesh and plug. Chir Ital. 2003;55(60):887 891. 9. Piccio M. Randomized controlled trial of preservation or elective division of illioinguinal nerve on open inguinal hernia repair with polypropylene mesh. Arch Surg. 2004;139(7):755 758. 10. Earle D, Romanelli J. Prosthetic materials for hernia: what s new. Contemp Surg. 2007;63(2)63 69. 11. Ansaloni L, Catena F, D Alessandro L. Prospective randomized, double-blind, controlled trial comparing Lichtenstein s repair of inguinal hernia with polypropylene mesh versus urgisis gold soft tissue graft: preliminary results. Acta Biomed. 2003; 74(Suppl 2):10 14. 12. Aasvang E, Kehlet H. Surgical management of chronic pain after inguinal hernia repair. Br J Surg. 2005;92:795 801. 568