Sleep Spindle Detection Based on Complex Demodulation Jia-bin LI, Bei WANG* and Yu ZHANG

Similar documents
Outlining a simple and robust method for the automatic detection of EEG arousals

Research Article A Comparison Study on Multidomain EEG Features for Sleep Stage Classification

International Journal of Bioelectromagnetism Vol. 14, No. 4, pp , 2012

linkedin.com/in/lizziehillsleeptechservices 1

LEARNING MANUAL OF PSG CHART

SLEEP STAGING AND AROUSAL. Dr. Tripat Deep Singh (MBBS, MD, RPSGT, RST) International Sleep Specialist (World Sleep Federation program)

The AASM Manual for the Scoring of Sleep and Associated Events

Proceedings 23rd Annual Conference IEEE/EMBS Oct.25-28, 2001, Istanbul, TURKEY

Recognition of Sleep Dependent Memory Consolidation with Multi-modal Sensor Data

Quick detection of QRS complexes and R-waves using a wavelet transform and K-means clustering

Simplest method: Questionnaires. Retrospective: past week, month, year, lifetime Daily: Sleep diary What kinds of questions would you ask?

MODEL-BASED QUANTIFICATION OF THE TIME- VARYING MICROSTRUCTURE OF SLEEP EEG SPINDLES: POSSIBILITY FOR EEG-BASED DEMENTIA BIOMARKERS

Developmental Changes Including Neonatal EEG. Gregory L. Holmes, MD

AUTOMATED SLEEP SCORING SYSTEM USING LABVIEW. A Thesis PARIKSHIT BAPUSAHEB DESHPANDE

Arousal detection in sleep

ARMA Modelling for Sleep Disorders Diagnose

Analysis of EEG Signal for the Detection of Brain Abnormalities

Sleep Stage Estimation By Evolutionary Computation Using Heartbeat Data and Body-Movement

Automatic Sleep Stages Detection Based on EEG Signals Using Combination of Classifiers

EEG Arousals: Scoring Rules and Examples. A Preliminary Report from the Sleep Disorders Atlas Task Force of the American Sleep Disorders Association

ARMA Modelling of Sleep Spindles

Human Brain Institute Russia-Switzerland-USA

Hyatt Moore IV 1, 2 Steve Woodward 3, PhD Emmanuel Mignot 1, MD, PhD. Electrical Engineering Stanford University, CA 2

ISSN: (Online) Volume 3, Issue 7, July 2015 International Journal of Advance Research in Computer Science and Management Studies

Basics of Polysomnography. Chitra Lal, MD, FCCP, FAASM Assistant professor of Medicine, Pulmonary, Critical Care and Sleep, MUSC, Charleston, SC

Automatic Sleep Arousal Detection based on C-ELM

Selection of Feature for Epilepsy Seizer Detection Using EEG

Sleep Stage Estimation Based on Approximate Heartrate Calculated from Other Persons

Development of 2-Channel Eeg Device And Analysis Of Brain Wave For Depressed Persons

Removing ECG Artifact from the Surface EMG Signal Using Adaptive Subtraction Technique

Beyond the Basics in EEG Interpretation: Throughout the Life Stages

Mental State Sensing and the Goal of Circuit-Synapse Synergy

Processed by HBI: Russia/Switzerland/USA

Effects of Light Stimulus Frequency on Phase Characteristics of Brain Waves

CHAPTER 6 INTERFERENCE CANCELLATION IN EEG SIGNAL

EEG in Medical Practice

H-Reflex Suppression and Autonomic Activation During Lucid REM Sleep: A Case Study

PERFORMANCE CALCULATION OF WAVELET TRANSFORMS FOR REMOVAL OF BASELINE WANDER FROM ECG

Automated Detection of Epileptic Seizures in the EEG

Nature Medicine: doi: /nm.4084

Automated Sleep Stage Analysis Using Hybrid Rule-Based and Case-Based Reasoning

MOVEMENT RULES. Dr. Tripat Deep Singh (MBBS, MD, RPSGT, RST) International Sleep Specialist (World Sleep Federation program)

Minimum Feature Selection for Epileptic Seizure Classification using Wavelet-based Feature Extraction and a Fuzzy Neural Network

arxiv: v1 [cs.lg] 4 Feb 2019

FREQUENCY DOMAIN BASED AUTOMATIC EKG ARTIFACT

Emotion Detection Using Physiological Signals. M.A.Sc. Thesis Proposal Haiyan Xu Supervisor: Prof. K.N. Plataniotis

EPILEPTIC SEIZURE DETECTION USING WAVELET TRANSFORM

Sleep Staging with Deep Learning: A convolutional model

Nature Neuroscience: doi: /nn Supplementary Figure 1

Seizure onset can be difficult to asses in scalp EEG. However, some tools can be used to increase the seizure onset activity over the EEG background:

Epileptic seizure detection using linear prediction filter

Classification of People using Eye-Blink Based EOG Peak Analysis.

The impact of numeration on visual attention during a psychophysical task; An ERP study

EEG, ECG, EMG. Mitesh Shrestha

Correlation Dimension versus Fractal Exponent During Sleep Onset

Classification of ECG Data for Predictive Analysis to Assist in Medical Decisions.

Non-Contact Sleep Staging Algorithm Based on Physiological Signal Monitoring

CLASSIFICATION OF SLEEP STAGES IN INFANTS: A NEURO FUZZY APPROACH

Asian Epilepsy Academy (ASEPA) & ASEAN Neurological Association (ASNA) EEG Certification Examination

Brain Computer Interface. Mina Mikhail

Asian Epilepsy Academy (ASEPA) EEG Certification Examination

A spike detection method in EEG based on improved morphological filter

Polysomnography Artifacts and Updates on AASM Scoring Rules. Robin Lloyd, MD, FAASM, FAAP 2017 Utah Sleep Society Conference

ECG Beat Recognition using Principal Components Analysis and Artificial Neural Network

PSD Analysis of Neural Spectrum During Transition from Awake Stage to Sleep Stage

Normal EEG of wakeful resting adults of years of age. Alpha rhythm. Alpha rhythm. Alpha rhythm. Normal EEG of the wakeful adult at rest

Sleep stages. Awake Stage 1 Stage 2 Stage 3 Stage 4 Rapid eye movement sleep (REM) Slow wave sleep (NREM)

A Modified Method for Scoring Slow Wave Sleep of Older Subjects

Assessment of Reliability of Hamilton-Tompkins Algorithm to ECG Parameter Detection

1. Introduction

ANALYSIS OF BRAIN SIGNAL FOR THE DETECTION OF EPILEPTIC SEIZURE

NORAH Sleep Study External Comment Mathias Basner, MD, PhD, MSc

USING CORRELATION COEFFICIENT IN ECG WAVEFORM FOR ARRHYTHMIA DETECTION

True Epileptiform Patterns (and some others)

ENHANCED SLEEP SPINDLE DETECTOR BASED ON THE FUJIMORI METHOD

Stage-independent, single lead EEG sleep spindle detection using the continuous wavelet transform and local weighted smoothing

Sleep Stages and Scoring Technique

ISSN: ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 2, Issue 10, April 2013

Various Methods To Detect Respiration Rate From ECG Using LabVIEW

Classification of EEG signals in an Object Recognition task

Definition of the Instantaneous Frequency of an Electroencephalogram Using the Hilbert Transform

Removal of Baseline Wander from Ecg Signals Using Cosine Window Based Fir Digital Filter

Design and Implementation of a Real-time Sleep Stage Monitoring and Classification System Using Support Vector Machine, for Narcolepsy Diagnosis

Neurophysiology & EEG

EE 4BD4 Lecture 11. The Brain and EEG

Analysis of the Effect of Cell Phone Radiation on the Human Brain Using Electroencephalogram

Applying Data Mining for Epileptic Seizure Detection

SPECTRAL ANALYSIS OF LIFE-THREATENING CARDIAC ARRHYTHMIAS

The connection between sleep spindles and epilepsy in a spatially extended neural field model

The AASM Manual for the Scoring of Sleep and Associated Events

ONLINE SEIZURE DETECTION IN ADULTS WITH TEMPORAL LOBE EPILEPSY USING SINGLE-LEAD ECG

Contents Sleep stage scoring Sleep regulation Sleep stage scoring in infants Sleep spindles 11

An Edge-Device for Accurate Seizure Detection in the IoT

A Review on Sleep Apnea Detection from ECG Signal

EEG signal classification using Bayes and Naïve Bayes Classifiers and extracted features of Continuous Wavelet Transform

Neonatal EEG Maturation

Classification of Epileptic EEG Using Wavelet Transform & Artificial Neural Network

Biomedical Signal Processing

Correlation analysis of seizure detection features

EEG History. Where and why is EEG used? 8/2/2010

Transcription:

International Conference on Biomedical and Biological Engineering (BBE 216) Sleep Spindle Detection Based on Complex Demodulation Jia-bin LI, Bei WANG* and Yu ZHANG Department of Automation, School of Information Science and Engineering, East China University of Science and Technology, Shanghai 2237, CHINA *beiwang@ecust.edu.cn Keywords: Sleep spindle, Complex demodulation, Sleep stage. Abstract. In this paper, we investigated the characteristic waveform of sleep spindle by using complex demodulation method (CDM). The ultimate purpose is to develop the automatic sleep spindle detection algorithm for overnight sleep data inspection. The main method includes four procedures. Firstly, the influences of disturbance of alpha waves, eye movement and muscle artifacts are analyzed and eliminated. Secondly, CDM is adopted to obtain the changing amplitude for sleep spindles. After CDM analysis, a set of parameters are calculated to find the candidate waveforms. Finally, the judgments of sleep spindle are made according to the defined thresholds of parameters. The overnight sleep recordings of three subjects were analyzed. Compared with the visual inspection of sleep stages by clinician, the obtained results showed that the detected sleep spindle were mostly distributed at sleep stage 2 and deep sleep stages. It is testified that CDM can well depict the instantaneous character of sleep spindle. The presented method can be an assistant tool for sleep spindle detection and sleep stage determination. Introduction Sleep spindle is one kind of EEG (electroencephalogram) wave whose duration is about.5-2 seconds. It is a transient waveform with waxing-waning amplitude. The frequency of sleep spindle is about 11-15Hz, most commonly 12-14Hz. Sleep spindle is related to sleep stages and sleep disorders. According to R&K criteria [1], sleep spindle exhibits strong presence in stage 2 of NREM (Non-Rapid Eye Movement). P.Y. Ktonas et al used Markov model to analyze the dynamic changing of sleep spindle and found that the distribution of spindles during overnight sleep complied with static regulation [2]. Sleep spindle also corresponds to the cognitive function of brain. A. Ayoub et al pointed out that high frequency spindle relates to the cognition [3]. Q. Li et al compared the character of sleep spindle of infant and concluded that there exists relationship between abnormal sleep spindle and hypophrenia [4]. In addition, the character of sleep spindle can reflect the character of brain disease such as epilepsy. A. Bersaqliere et al discovered that electrical sources of sigma activity (12-16Hz) which included spindle activity exhibited increased activity during the ictal phase which was higher in the epileptogenic hemisphere [5]. Studying sleep spindle is of importance in medicine. Hence, many methods and characters are used to detect sleep spindle automatically. A. Parekh et al detected spindle by time-frequency sparsity [6]. M. Muammar et al mentioned an automatic sleep spindle detection algorithm based on synchrosqueenzing [7]. M. Adamczyk et al proposed an automatic sleep spindle detection method using continuous wavelet transform [8]. Machine learning is also used for spindle detection. E.M.Ventouras et al used Artificial Neural Network [9] and N.Acir et al used Supported Vector Machine to detect sleep spindle [1]. 216. The authors - Published by Atlantis Press 62

In this paper, the complex demodulation method (CDM) is adopted to detect sleep spindle automatically. CDM is a time-frequency method which can extract the instantaneous amplitude of signal [11]. It has been used to analyze R-R interval which is time elapsing between two QRS complexes in EKG (electrocardiogram) [12]. CDM is useful in analyzing changing signals. Sleep spindle has transient character of frequency and amplitude. An automatic sleep spindle detection algorithm based on CDM is developed. The overnight sleep data were analyzed to evaluate the effectiveness of presented method. Method Data Acquisition The overnight polysomnographic (PSG) recordings were obtained from 3 subjects. The PSG recordings of each subject included 4 EEG channels (C3/A2, C4/A1, O1/A2, O2/A1), 2 EOG channels (LOC/A1, ROC/A1) and one chin EMG channel (chin-emg) according to the International 1-2 system. EEGs and EOGs were recorded under a sampling rate of 1Hz, with a high frequency cut off of 35Hz and a time constant of.3s. Chin-EMG was recorded under a sampling rate of 2Hz, with a high frequency cutoff of 7Hz and a low frequency cutoff of 1Hz. In this paper, EEGs recorded on C3/A2 and C4/A1 were used to detect sleep spindle. EEGs recorded on O1/A2 and O2/A1 were utilized to analyze the influence of alpha components. Meanwhile, EOGs and chin-emg were analyzed to remove the influence of eye movement and muscle interference. Sleep spindle is detected automatically for every 3s epoch. The result is analyzed comparing with the visual inspection of sleep stages by a qualified clinician. Sleep Spindle Detection Pre-processing. Sleep spindle is sometimes obfuscated with alpha wave. The frequency of alpha component is 8-13Hz which is overlapped with the frequency of sleep spindle. In order to remove the influence of alpha wave, the ratio of the amount of alpha wave R α is calculated by equation in Table 1 from O1/A2 and O2/A1 channels. If R α is larger than 3%, the epoch is excluded. Additionally, the influence of EOG and EMG may affect the EEG waveform and cause erroneous judgment for sleep spindle detection. The amount of eye movement and muscle activity are calculated as in Table 1. If S LOC or S ROC is larger than 3μv 2, or S chin-emg is larger than1μv 2, the epoch is excluded. Table 1. Parameters of pre-processing Meaning Parameter Method EEG Ratio[%] R α Max{S α (O1)/S T (O1), S α (O2)/S T (O2)} EOG Amount[μv 2 ] S LOC, S ROC S LOC (LOC), S ROC (ROC) Chin-EMG Amount[μv 2 ] S chin-emg S chin-emg (chin-emg) * T(.5-25Hz); α(8-13hz); LOC, ROC(2-1Hz); chin-emg(25-1hz) Complex Demodulation A time series X(n t) can be represented as, X ( n t) A( cos[ fn t P( ], (1) Where A(n t ) is a changing amplitude and P(n t) is a changing phase. A(n t) can be extracted as follows if the frequency f is known: 63

Shift all the frequency in X(n t) by -f : Y ( X ( 2exp( if A( [exp( ip( ) exp( i{2 fn t P( })]. (2) Let Y (n t) be the complex signal when Y(n t) is passed through a low-pass filter: Y ( A( exp[ ip( ]. Therefore, A(n t) can be obtained as : (3) A( Y (. (4) Sleep spindle usually can be observed in channel C3/A2 and C4/A1. Its frequency is around 11-15Hz, most commonly 12-14Hz. CDM is used to analyze the EEG signal of C3/A2 and C4/A1 for every 3s epoch. The changing amplitude of EEG signal around the frequency of 13Hz is analyzed. In the above equations, f is set as 13Hz and X(n t) is the original raw EEG data of a 3s epoch. Finally, A(n t) is the obtained instantaneous amplitude for the frequency components around 13Hz by CDM. Parameter Calculation The frequency of EEG before or after sleep spindle is smaller. Meanwhile, the amplitude of sleep spindle increases quickly and then decreases. As a result, there will be a peak of wave in the instantaneous amplitude curve when sleep spindle appears. According to the result of CDM, candidate waveforms are selected. Here, the average of instantaneous amplitude is calculated as follow: N 1 mean A(, (5) N n 1 where, N is the total data number of an epoch. At first, all of the local maximum points within one epoch are found. If its instantaneous amplitude is larger than twice of the mean, a peak point t p is marked and the corresponding EEG signal is selected as candidate waveform. The starting and ending points (t start and t final ) are the position of the nearest local minimum points from the left and right of t p whose instantaneous amplitude is smaller than the mean. Table 2. Parameters for sleep spindle detection Characteristic parameters peak[μv] duration[s] rising speed[μv/s] falling speed[μv/s] Judgments A(t p ) 3μv.5s t final -t start -.5 2s 4μv/s.5peak/(t p -t 1 ) 1μv/s 4μv/s.5peak/(t 2 -t p ) 1μv/s After selecting the candidate waveforms, the characteristic parameters are calculated as illustrated in Table 2. There are totally four characteristic parameters. Peak is the instantaneous amplitude of 13Hz signal at t p. Duration equals to the time difference between starting and ending positions minus.5 seconds which is the delay time caused by CDM. Rising speed is the average speed when the instantaneous amplitude increased from.5*peak to peak, where t 1 is the nearest point from the left of t p whose amplitude equals to.5*peak. Falling speed is the average speed when the 64

instantaneous amplitude decreased from peak to.5*peak, where t 2 is the nearest point from the right of t p whose amplitude equals to.5*peak. Sleep Spindle Detection For each candidate waveform, the character parameters are compared with a set of defined threshold as in Table 2. The peak should be larger than 3μv, which means the amplitude is large enough corresponding to the appearance of sleep spindle. According to the definition of sleep spindle, the duration should be within.5-2 seconds. Additionally, the rising speed and falling speed are evaluated with the range from 4μv/s to 1μv/s, which corresponding to the sharp waveform of instantaneous amplitude in the CDM. Either the rising speed or falling speed meets the requirement, this condition is satisfied. Finally, when all the conditions are satisfied, the candidate waveform is judged as a detected sleep spindle. Result Complex Demodulation After pre-processing, the epochs which contained alpha activity and active eye movement of muscle artifacts were excluded for further analysis. CDM was applied for each remained epoch. In Fig.1, the raw EEG of C4/A1 of one epoch was shown in (a) and its instantaneous amplitude by CDM was in (b). Several sharp waveforms were detected in Fig.1 (b). The frequency components around 13 Hz can be observed at the same positions in Fig.1 (a). Those waveforms were selected as the candidate waveforms which are marked by empty circles in Fig.1 (b). Amplitude/uv Amplitude/uv Amplitude/uv Amplitude/uv 3 C4-A1 2 C4-A1 3 1 2 1-1 -2-1 -3-2 1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 16 17 18 19 2 21 22 23 24 25 26 27 28 29 3-3 time/s 1 2 3 4 5 6 7 8 9 1 11 12 13 instantaneous 14 15 amplitude 16 17 18 19 2 21 22 23 24 25 26 27 28 29 3 6 (a) Raw EEG of time/s C4/A1 channel 5 instantaneous amplitude 6 4 5 3 4 2 3 1 2 1 1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 16 17 18 19 2 21 22 23 24 25 26 27 28 29 3 time/s 1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 16 17 18 19 2 21 22 23 24 25 26 27 28 29 3 time/s (b) Instantaneous amplitude of frequency components around 13 Hz by CDM Figure 1 CDM result for a 3s epoch Totally, there are four candidate waveforms selected. The characteristic parameters of the candidate waveforms were shown in Table 3. Comparing with the judgment conditions in Table 2, the first candidate waveform does not meet the requirement as its value of peak is smaller than 3μv. The latter three candidate waveforms were satisfied with the requirements. Finally, the sleep spindles were detected at 18s, 23s and 27s for the epoch shown in Fig.1. 65

Table 3. Characteristic parameter values of candidate sleep spindles t p [s] Peak[μv] Rising speed[μv/s] Falling speed[μv/s] Duration[s] 2.6 2.33 4.66 3.53.82 18.64 3.47 5.26 3.4.79 22.82 4.93 7.25 4.93 1.76 27.34 4.3 5.3 4.11 1.1 Sleep Spindle Detection The overnight sleep data of three subjects were tested. In Table 4, the epoch numbers with detected sleep spindles were counted and compared with the visual inspection of sleep stages. The epochs were classified into six sleep stages of awake, stage 1, stage 2, stage 3, stage 4 and REM (Rapid eye movement) according to the visual inspection. Sleep spindle is the characteristic waveform for stage 2. Totally, subject 1 has 489 epochs inspected as stage 2, while subject 2 and subject 3 have 348 and 422 epochs correspondingly. The sleep spindle detection result in Table 4 showed that, to all subjects, nearly half of the epochs of stage 2 were detected with sleep spindles. Stage 3 and 4 are deep sleep where sleep spindle can also be observed. About 3% of the epochs of stage 3 and 4 were detected with sleep spindles. In stage awake, large amount of alpha components can be observed when the subject closed eyes and began to sleep. Subject 1 has totally 197 epochs of stage awake and 16 epochs were detected with sleep spindle. Subject 3 has totally 135 epochs of stage awake and 12 epochs were detected with sleep spindle. There was no spindle detected in stage awake in subject 2. Stage 1 is the transit stage from awake to sleep. To all subjects, there were also a few spindles detected in stage 1. To subject 1, there was no spindle detected in stage REM. 16 epochs of subject 2 and 3 epochs of subject 3 of stage REM were detected with spindles. The obtained results were fairly well compared with occurrence of sleep spindle and sleep stages. Table 4. Detected sleep spindle and sleep stages Awake Stage 1 Stage 2 Stage 3 Stage 4 REM Subject1 16(197) 4(51) 22(489) 28(94) 5(45) (18) Subject2 (132) 43(149) 13(348) 6(48) 7(11) 16(137) Subject3 12(135) 48(11) 378(422) 27(95) 4(53) 3(177) Summary In this study, an automatic sleep spindle detection algorithm based on CDM was introduced. Pre-processing is utilized to exclude the contaminated epochs by alpha, eye movement and muscle artifacts which is efficient to decrease the error of spindle detection. The instantaneous amplitude of frequency components around 13Hz by CDM reflected the instantaneous characteristics of spindle. The overnight sleep data were analyzed. The obtained results were quite satisfied comparing with the visual inspection of sleep stage. The detected sleep spindle were mostly in stage 2 and deep sleep stages which is consistent with the definition of sleep spindle in R&K sleep criteria. The presented method can be an assistant tool for sleep spindle detection and automatic sleep stage determination. 66

Acknowledgement This research was financially supported by the Scientific Research Foundation for the Returned Overseas Chinese Scholars, State Education Ministry, the Shanghai Natural Science Foundation under Grant 16ZR1475. References [1] A. Rechtschaffen, A.A. Kales, Manual of standardized terminology, techniques and scoring system for sleep stages of human subject, California Brain Information Service, USA, 1968, pp.1-78. [2] P.Y. Ktonas, T. Paparrigopoulos, E.A. Monoyious, Sleep spindle incidence dynamics: a pilot study based on a Markovian analysis, J. Sleep. 23 (2) 419-423. [3] A. Ayoub, D. Aumann, A. Horschelmann, et al, Differential effects on fast and slow spindle activity, and the sleep slow oscillation in humans with carbamazepine and flunarizine to antagonize voltage-dependent na(+) and ca(2+) channel activity, J. Sleep. 36 (213) 95-911. [4] Q. Li, M. Geng, C.X. Wang, The research of the relationship between abnormal sleep spindles wave and infants mental relationship, J. JMEP. 19 (212) 9-11. [5] A. Bersaqliere, P. Achermann, G. Lo Russo, P. Proserpio, L. Nobili, Spindle frequency activity may provide lateralizing information in drug-resistant nocturnal mesial frontal lobe epilepsy : a pilot study on the contribution of sleep recordings, J. Seizure. 22 (213) 719-725. [6] A. Parekh, I.W. Selesnick, D.M. Rapoport, I. Ayappa, Detection of K-complexes and sleep spindles (DETOKS) using sparse optimization, J. Neurosci Methods. 251 (215) 37-46. [7] M.Muammar, R.Tafreshi, D.B.Boivin, N.Haddad, Enhanced automated sleep spindle detection algorithm based on synchrosqueezing, J. Med Biol Enq Comput. 53 (215) 635-644. [8] M. Adamczyk, L. Genzel, M. Dresler, A. Steiger, E. Friess, Automatic sleep spindle detection and genetic influence estimation using continuous wavelet transform, J. Frontiers in human neuroscience. 9 (215) Article 624. [9] E.M. Ventouras, E.A. Monoyiou, P.Y. Ktonas et al, Sleep spindle detection using artificial neural networks trained with filtered time-domain EEG: a feasibility study, J. Computer methods and programs in biomedicine. 78 (25) 91-27. [1] N. Acir, C. Guzelis, Automatic recognition of sleep spindles in EEG via radial basis support vector machine based on a modified feature selection algorithm, J. Neural Computing & Applications.14 (25) 56-65. [11] S.J. Shin, W.N. Tapp, S.S. Reisman, Assessment of autonomic regulation of heart rate variability by the method of complex demodulation, J. Transaction on biomedical engineering. 36 (1989) 274-283. [12] L.A. Lipsitz, J. Hayano, S. Sakata, et al, Complex demodulation of cardiorespiratory dynamics preceding vasovagal syncope, J. Circulation. 98 (1998) 977-983. 67