Basics of Quantification of ASL

Similar documents
Perfusion MRI. Youngkyoo Jung, PhD Associate Professor Radiology, Biomedical Engineering, and Clinical & Translational Science Institute

Perfusion-Based fmri. Thomas T. Liu Center for Functional MRI University of California San Diego May 7, Goal

ASL BASICS II. Learning Objectives. Outline. Acquisition. M. A. Fernández-Seara, Ph. D. Arterial spin labeled perfusion MRI: basic theory

PHYSICS OF MRI ACQUISITION. Alternatives to BOLD for fmri

Assessment of longer post-labeling delays to measure CBF using pseudo-continuous ASL with background suppression

Arterial spin labeling perfusion MRI: reproducibility & clinical applications Gevers, J.K.M.

Turbo ASL: Arterial Spin Labeling With Higher SNR and Temporal Resolution

Cover Page. The handle holds various files of this Leiden University dissertation

Field Strength. Regional Perfusion Imaging (RPI) matches cerebral arteries to flow territories

Cover Page. The handle holds various files of this Leiden University dissertation

Perfusion Physics. ICMRI2018 March 29-31, 2018 Grand Hilton Hotel, Seoul, Korea. Asian Forum Ⅱ: Perfusion MRI SY24-1.

Daniel Bulte. Centre for Functional Magnetic Resonance Imaging of the Brain. University of Oxford

ORIGINAL ARTICLE. Jack A Wells 1, Bernard Siow 1,2, Mark F Lythgoe 1,4 and David L Thomas 3,4

ASL Perfusion Imaging: Concepts and Applications

PERFUSION MRI CONTRAST BASED TECHNIQUES

Magnetic resonance techniques to measure distribution of cerebral blood flow

Abstract. Introduction. Material and Methods. Results. Conclusion

MR Advance Techniques. Vascular Imaging. Class II

Magnetic Resonance Angiography

Arterial Spin Labeling Measurement of Cerebral Perfusion in Children With Sickle Cell Disease

Feasibility of using Arterial Spin Labeling for Detecting Longitudinal Changes in Cerebral Blood Flow

CORE II: Functional MRI

Quantitative assessment of brain perfusion with magnetic resonance imaging

Reproducibility of the Quantification of Arterial and Tissue Contributions in Multiple Postlabeling Delay Arterial Spin Labeling

Arterial Spin Labeling in Body MR

Speed, Comfort and Quality with NeuroDrive

An obstructive lesion in the internal carotid artery (ICA)

Non Contrast MRA. Mayil Krishnam. Director, Cardiovascular and Thoracic Imaging University of California, Irvine

Cortical hypoperfusion in Parkinson's disease assessed with arterial spin labeling MRI

DEVELOPMENT OF IMPROVED ARTERIAL SPIN LABELING METHODS IN HUMANS AND ANIMAL MODELS MEGAN ELISA JOHNSTON

Arterial spin labeling perfusion MRI: Inter-vendor reproducibility and clinical applicability Mutsaerts, H.J.M.M.

1Pulse sequences for non CE MRA

非對比劑與對比劑增強 MRA. 血管攝影與對比劑 A Course of MRI. 本週課程內容 -MR Angiography (MRA) Unenhanced MRA

Arterial spin labeling perfusion MRI: Inter-vendor reproducibility and clinical applicability Mutsaerts, H.J.M.M.

Functional MRI with Magnetization Transfer Effects: Determination of BOLD and Arterial Blood Volume Changes

Arterial Transit Time Imaging With Flow Encoding Arterial Spin Tagging (FEAST)

Investigation of the correlation between cerebral blood flow and bold

6/23/2009. Inversion Recovery (IR) Techniques and Applications. Variations of IR Technique. STIR, FLAIR, TI and TI Null. Applications of IR

Biophysical and physiological bases of fmri signals: challenges of interpretation and methodological concerns

Magnetic Resonance Imaging. Basics of MRI in practice. Generation of MR signal. Generation of MR signal. Spin echo imaging. Generation of MR signal

A New Trend in Vascular Imaging: the Arterial Spin Labeling (ASL) Sequence

Supplementary Online Content

Essentials of Clinical MR, 2 nd edition. 99. MRA Principles and Carotid MRA

Hemodynamics and fmri Signals

A Primer on Functional Magnetic Resonance Imaging

Fat Suppression in the Abdomen

Magnetization Preparation Sequences

NIH Public Access Author Manuscript Magn Reson Med. Author manuscript; available in PMC 2010 February 1.

MR Advance Techniques. Cardiac Imaging. Class III

Fully-Automatic Determination of the Arterial Input Function for Dynamic Contrast-Enhanced Pulmonary MR Imaging (DCE-pMRI)

Functional Magnetic Resonance Imaging with Arterial Spin Labeling: Techniques and Potential Clinical and Research Applications

Whole brain CT perfusion maps with paradoxical low mean transit time to predict infarct core

Background suppression in arterial spin labeling MRI with a separate neck labeling coil

Raja Muthupillai, PhD. Department of Diagnostic and Interventional Radiology St. Luke s Episcopal Hospital. Research Support: Philips Healthcare

Master Thesis in Radiation Physics 09/10 Annie Olsson. Supervisors: Frank Risse Lars E. Olsson. Imaging centre AstraZeneca R&D Mölndal

MRI qbold Based Evaluation. Renal Oxidative Metabolism. Department of Radiology and Hernando Gomez, MD Critical Care Medicine

Clinical approach of perfusionweighted

APPLICATIONS OF ASL IN NEUROSCIENCE

Per-subject characterization of bolus width in Pulsed Arterial. Spin Labeling using Bolus Turbo Sampling (BoTuS)

Simultaneous Acquisition of Cerebral Blood Volume-, Blood Flow-, and Blood Oxygenation-Weighted MRI Signals at Ultra-High Magnetic Field

INTRO TO BOLD FMRI FRANZ JOSEPH GALL ( ) OUTLINE. MRI & Fast MRI Observations Models Statistical Detection

Cerebral Perfusion and Arterial Transit Time Changes During Task Activation Determined With Continuous Arterial Spin Labeling

Synthesized Magnetic Resonance Imaging

Study of the CNS. Bent O. Kjos' Richard L. Ehman Michael Brant-Zawadzki William M. Kelly David Norman Thomas H. Newton

Non-Contrast MRA. How and When 1996! Why Non-Contrast MRA? Angiography: What are our goals? Inflow Techniques Differences in excitation hx

Hemodynamics and fmri Signals

Evaluation of Intracranial Vasculatures in Healthy Subjects with Arterial-Spin-Labeling-Based 4D-MR Angiography at 3T

In patients presenting with stroke-like symptoms, MRI can

Arterial Cerebral Blood Volume Weighted Functional MRI Using Pseudocontinuous Arterial Spin Tagging (AVAST)

MR Advance Techniques. Cardiac Imaging. Class IV

Invited. Methodology of Brain Perfusion Imaging. Review. Emmanuel L. Barbier, PhD, 1,2 Laurent Lamalle, PhD, 1 and Michel Décorps, PhD 1 *

CARDIAC MRI. Cardiovascular Disease. Cardiovascular Disease. Cardiovascular Disease. Overview

Perforating arteries originating from the posterior communicating artery: a 7.0-Tesla MRI study

Quantification of myocardial perfusion by cardiovascular magnetic resonance

Experimental Assessment of Infarct Lesion Growth in Mice using Time-Resolved T2* MR Image Sequences

Quantitative Analysis of Arterial Spin Labeling FMRI Data Using a General Linear Model

Received: 17 December 2008, Revised: 24 August 2009, Accepted: 2 September 2009, Published online in Wiley InterScience: 1 December 2009

Functional Chest MRI in Children Hyun Woo Goo

Dynamic susceptibility contrast MR imaging was performed to determine the local cerebral blood flow and blood volume.

Table 1. Summary of PET and fmri Methods. What is imaged PET fmri BOLD (T2*) Regional brain activation. Blood flow ( 15 O) Arterial spin tagging (AST)

Brain Perfusion Imaging in a Case of Thalamic Stroke: a Clinical Application of 3D Pseudo-Continuous ASL (PCASL)

Pseudocontinuous Arterial Spin Labeling Quantifies Relative Cerebral Blood Flow in Acute Stroke

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

Repeatability of 2D FISP MR Fingerprinting in the Brain at 1.5T and 3.0T

The Low Sensitivity of Fluid-Attenuated Inversion-Recovery MR in the Detection of Multiple Sclerosis of the Spinal Cord

When perfusion meets diffusion: in vivo measurement of water permeability in human brain

Modifi ed CT perfusion contrast injection protocols for improved CBF quantifi cation with lower temporal sampling

Investigations in Resting State Connectivity. Overview

A Two-Stage Model for In Vivo Assessment of Brain Tumor Perfusion and Abnormal Vascular Structure Using Arterial Spin Labeling

One hundred percent oxygen inhalation causes arterial vasoconstriction

A neuroradiologist s guide to arterial spin labeling MRI in clinical practice

An investigation of statistical power for continuous arterial spin labeling imaging at 1.5 T

Calibrated MRI to evaluate cerebral hemodynamics in patients with an internal carotid artery occlusion

Comparative Study of Pseudo-Continuous Arterial Spin Labeling and Dynamic Susceptibility Contrast Imaging at 3.0 Tesla in Brain Tumors

New Imaging Concepts in Central Nervous System Neoplasms

Outline. Why Image Animals?

Non-Invasive MR-based Evaluation of Kidney Function without Exogenous Contrast Agent. Xiang He, PhD Department of Radiology University of Pittsburgh

Transcription:

Basics of Matthias van Osch Contents Thoughts about quantification Some quantification models Bloch equations Buxton model Parameters that need to be estimated Labeling efficiency M Bolus arrival time Bolus width T 1 of arterial blood/tissue T 2 of label Or use phase contrast MRA to calibrate CBF 2 2 Two kinds of quantification Multiplication factors to scale to absolute perfusion (ml/1ml/min) that are constant for the whole image Factors that differ within the ASL-image and therefore will change relative perfusion Transit time differences Labeling efficiency for different arteries Etc 3 3 1

Do we need absolute quantification? For many studies global scaling factors are not essential Scaling of ASL-images with respect to whole brain average How does disease affect blood flow distribution Relative perfusion of tumor compared to normal appearing GM/WM Comparison with contralateral hemisphere Correction for regional differences is often more important Absolute quantification is essential for whole brain diseases, like large vessel occlusive disease, neurodegenerative disease, sickle cell disease, etc Especially important when comparing patients to controls (differences in T 1, labeling efficiency, or brain perfusion?) 4 4 Arterial spin labeling 3) Acquire images of the brain 2) Wait 1-2 seconds for label to arrive in brain tissue 1) Label blood magnetically (inversion) Quantification LIBC of ASL 5 5 Monday, September 23, 213 Half-time of tracer 1 9 8 7 Signal (%) 6 5 4 3 2 16% 1 1 2 3 4 5 6 7 8 9 Time (s) The labeled spins decay with the longitudinal relaxation time T 1 (T 1,blood 165 ms @ 3Tesla) 6 2

Arrival-time of label pcasl PASL 1-3 s Transport time to imaging slice is approximately 1 sec Probably takes another 1-1.5 s to reach capillary bed Quantification Arterial spin labeling of ASL 7 Monday, September 23, 213 7 Arrival-time of label vs decay of tracer 1 pcasl 1-3 s 9 8 7 6 PASL Signal (%) 5 4 3 2 1 1 2 3 4 5 6 7 8 9 Time (s) Wait long for arrival of spins in microvasculature Image as quickly possible due to loss of label Quantification Arterial spin labeling of ASL 8 Monday, September 23, 213 8 Loss of label: longitudinal relaxation 1 ms 3 ms 6 ms 1 ms 15 ms 21 ms 26 ms 3 ms 35 ms Inflow of label Decay of label Angiogram Perfusion Noise The labeled spins decay with the longitudinal relaxation time T 1 (T 1,blood 165 ms @ 3Tesla) 9 3

Principle of arterial spin labeling ASL is based on tracer kinetics to measure blood flow, similar to the nitrous oxide method, perfusion CT and DSC-MRI Use blood as a tracer by inverting its longitudinal relaxation: NO CONTRAST AGENT Half-time of tracer governed by the longitudinal relaxation time Freely diffusing tracer: accumulation of tracer reflects blood flow Kety, S. S., and C. F. Schmidt. The nitrous oxide method for the quantitative determination of cerebral blood flow in man: theory, procedure, and normal values. J. Clin. Invest. 27: 17 119, 1948. 1 Quantification models I: Bloch Inflow of label Outflow of label Correction for differences in water content Under assumption of well mixed compartment Solution steady state: 11 11 Quantification models II: Buxton Magn Reson Med. 1998 Sep;4(3):383-96 12 12 4

Quantification models II: Buxton Labeling efficiency Delivery function Normalized arterial concentration of magnetization at voxel Residue function Fraction of tagged spins arrived at t and still present at t Relaxation function Relaxation between t and t Formulation of ASL signal as a convolution 13 13 Labeling efficiency 14 14 Labeling efficiency of PASL Check inversion efficiency and profile in phantoms Redo these experiments in vivo, because B 1 -distribution is different in vivo than in phantoms Acquire images at different delay times (inversion recovery) 15 15 5

Labeling efficiency of PASL 3 25 MR-signal (a.u.) 2 15 1 5 2 4 6 8 1 12 14 16 Inversion time (ms) Remember: switch off pre-saturation pulses and post-labeling saturation 16 16 Labeling efficiency of PASL 3 25 MR-signal (a.u.) 2 15 1 5 2 4 6 8 1 12 14 16 Inversion time (ms) Remember: switch off pre-saturation pulses and post-labeling saturation Remember: modulus data rectifies noise 17 17 Labeling efficiency of PASL 3 25 MR-signal (a.u.) 2 15 1 5 2 4 6 8 1 12 14 16 Inversion time (ms) Labeling efficiency can be very close to 1% for PASL, but also check control condition 18 18 6

Labeling efficiency of CASL and pcasl Gradient More difficult to measure, because inversion is achieved by flowdriven (pseudo-)adiabatic inversion Labeling efficiency therefore frequently determined by means of simulation of Bloch equations Which you will be doing this afternoon 19 19 M M is the equilibrium signal (TR=, TE=) in a voxel containing 1% arterial blood Is therefore proportional to voxel volume Take care of scaling between scans on your scanner (M vs ASL) Measure M with PD-weighted sequence in vein Use reference ROI (WM or CSF) Use separate M scan 2 2 Separate M -scan PD-weighted sequence with similar readout as ASL Correct for differences in water content of tissue and blood (λ WM.82; λ GM.98) 1 Perform voxel-wise correction (=division) Also possible to use control image (be aware of T 1 -effects and should not be combined with background suppression!) 1 Herscovitch P, Raichle ME. J Cereb Blood Flow Metab. 1985 Mar;5(1):65-9 21 7

Separate M -scan Automatically correction for regional differences in T 2 (*) Assuming that T 2 (*) of ASL signal equals T 2 (*) of PD-signal (tissue dominated) 22 Errors in single echo ASL when assuming uniform T2* error map 6 4 2-2 -4-6 Mean relative error in S,s.e. (%) slice thickness difference ROI 5 mm 8 mm p-value frontal sinus 47 * 54 *.2 nasal cavity 37 ** 5 **. petrous bones 34 34.957 grey matter 1 1 1. white matter -7-7.862 Table shows relative error in S calculation from single echo approach assuming a uniform T 2* =5 msec as compared to dual echo approach. Errors can amount to more than 5%. In areas close to air containing cavities the error is significantly reduced with smaller slice thickness. Relative error in grey and white matter at a higher level is not significant. 23 May 27 23 Separate M -scan Automatically correction for regional differences in T 2 (*) Assuming that T 2 (*) of ASL signal equals T 2 (*) of PD-signal (tissue dominated) Also correction for B 1 -inhomogeneities and other scaling factors is achieved (i.e. parallel imaging) 24 8

16 14 12 1 8 6 4 2 16 14 12 1 8 6 4 2 Correcting B 1 -inhomogeneities 12 1 Error (%) 8 6 4 1% higher B 1 1% lower B 1 2 2 4 6 8 1 Excitation angle (degrees) Error in CBF as a function of readout flipangle 25 ASL @ 7T B 1 map With correction for B 1 26 ASL @ 7T B 1 map Without correction for B 1 27 9

Separate M -scan Automatically correction for regional differences in T 2 (*) Assuming that T 2 (*) of ASL signal equals T 2 (*) of PD-signal (tissue dominated) Also correction for B 1 -inhomogeneities and other scaling factors is achieved (i.e. parallel imaging) Without correcting for voxel-wise differences in lambda, some errors are made 1 Herscovitch P, Raichle ME. J Cereb Blood Flow Metab. 1985 Mar;5(1):65-9 28 Choice of TR TR = 2 ms 29 TR = 1 ms 29 M in CSF 25 2 MR-signal (a.u.) 15 1 5 5 1 15 2 Inversion time (ms) Same readout as ASL Inversion pulse of background suppression Perform fit 3 1

M in CSF 25 2 MR-signal (a.u.) 15 1 5 5 1 15 2 Inversion time (ms) TE TE * * T 2, CSF T 2, blood. M, CSF blood M, blood M, CSF e 87 CSF e TE TE * * T 2, CSF T 2, blood 31 Comparison of M -methods pcasl FAIR ROI in CSF Voxelwise M -map ROI in WM Voxelwise M -map correction for λ WM and λ GM Control image as estimate for M Courtesy: Chen, Wang, Detre, ISMRM 211, abstract nr 3 32 Quantification models II: Buxton Delivery function Normalized arterial concentration of magnetization at voxel 33 33 11

Input function for PASL PASL Early arrival Little relaxation of label Later arrival More relaxation of label t Transit delay Bolus width Quantification Perfusion and of permeability ASL 34 Input function in PASL For PASL a large part of the vasculature is labeled. The amount of labeled spins is dependent on the volume of the arteries in the labeling plane (e.g. curved vessels, collateral pathways, etc). Will be different for different vessels (especially anterior vs posterior) Quantification Perfusion and of permeability ASL 35 Monday, September 23, 213 35 Bolus width ( Determined by width of labeling slab Or by extent of RF-coil Or is set by QUIPSS-time (temporal cut-off of the bolus) Can be measured by fitting multi-ti data Trailing edge Courtesy: Bokkers et al, AJNR Am J Neuroradiol. 28 p. 1698-73 36 12

Choice of QUIPSS time (ms, TI =24 ms) 15 3 45 6 75 9 1 No quipps Quantification Perfusion and of permeability ASL 37 Monday, September 23, 213 37 Input function for PASL and CASL PASL (p)casl t Transit delay t = Labeling duration Quantification Perfusion and of permeability ASL 38 Input function for PASL and CASL PASL (p)casl c e t T1, blood ( t) t t t t t t t c e t t T1, blood ( ) t t t t t t t Quantification Perfusion and of permeability ASL 39 13

How to determine t? Multi TI PASL Average arterial transit map (284 subjects) Courtesy: Petersen, Mouridsen, Golay. The QUASAR reproducibility study; NeuroImage Volume 49, Pages 14-113 4 Input function for PASL and CASL PASL (p)casl c e t T1, blood ( t) t t t t t t t c e t t T1, blood ( ) t t t t t t t Quantification Perfusion and of permeability ASL 41 T 1, blood 4.7Tesla 3.Tesla Silvennoinen,et al, Magn Reson Med. 23,p 568 571 Lu et al, Magn Reson Med. 24,p 679-82 Frequently, the value is taken from literature experiments in bovine blood 42 14

T 1, blood 43 T 1, blood Varela et al. NMR Biomed. 211 Jan;24(1):8-8 44 T 1, blood measurements Males Females 21 T 1, blood (ms) 185 16 135 1.5T 3T 7T Zhang, Petersen, Ghariq, De Vis, Webb, Teeuwisse, Hendrikse, van Osch. Magn Reson Med 212 Quantification T1 measurement of ASL 45 45 15

Quantification models II: Buxton label r(t)=exp(-ft/λ) Residue function Fraction of tagged spins arrived at t and still present at t Tissue Outflow: f M v =f M b /λ Assumption of well-mixed compartment 46 46 Quantification models II: Buxton Which T 1? T 1 of blood or of tissue? Relaxation function Relaxation between t and t Where is my label? Does it exchange immediately? 47 Exchange of label? Monitor T 2 -changes as a function of delay time GM WM 48 16

Two compartment model Conclusion: T 1,blood is best candidate, especially since moment of exchange is often unknown 49 Quantification models II: Buxton 1 PASL.65 CASL.82 pcasl PASL exp(-ft/λ) exp(-t/t 1,bl ) CASL 5 5 Buxton model: putting everything together.7.6.5.4.3.2.1 Transit time Inflow of label Decay and outflow of label -.1.5 1 1.5 2 2.5 3 51 17

Buxton model results.9.8.7 CBF 18; TA=.7; tau=.8 CBF 8; TA=.5; tau=1.2 CBF 88; TA=.5; tau=.8.6.5.4.3.2 Single TI.1.5 1 1.5 2 2.5 3 -.1 52 Influence of width of input function.7.6 Tau =.3 s Tau =.6 s.5.4.3.2.1 -.1.5 1 1.5 2 2.5 3 53 Buxton fit to multi-ti data.9.8.7 CBF 18; TA=.7; tau=.8 CBF 8; TA=.5; tau=1.2 CBF 88; TA=.5; tau=.8.6.5.4.3.2.1.5 1 1.5 2 2.5 3 -.1 54 18

Post-processing of (multi-ti) PASL QUASAR: deconvolution with input function Voxel-wise or ROI-wise fitting of Buxton model Fixation of parameters (especially, by means of QUIPSS) See Esben s presentation of tomorrow AIF WM GM residue Petersen et al, MRM 55:219 232 (26) 55 What is recommended? 56 56 White paper recommendation 57 57 19

White paper recommendation 58 58 Table 3 of white paper Parameter Value λ (blood-brain partition coefficient).9 ml/g (1) T 1, blood at 3. Tesla 165 ms (2) T 1, blood at 1.5 Tesla 135 ms (3) α (labeling efficiency) for PCASL.85 (4) α (labeling efficiency) for PASL.98 (5) 1) Herscovitch P. JCBFM1985;5(1):65-69 2) Lu H. Magn Reson Med 24;52(3):679-682 3) Lu H. Magn Reson Med 23;5(2):263-274. 4) Dai W. Magn Reson Med 28;6(6):1488-1497 5) Wong E. Magn Reson Med 1998;4(3):348-355 59 59 White paper recommendation 6 6 2

Recommendation Conversion to ml/1ml/min M (ASL-signal) ASL is based on inversion Labeling efficiency M : proton density scan corrected for difference in proton content between water and tissue 61 61 Recommendation,, =,,,, 62 62 Amount of label,, =,,,,,,, =, 1, T 1 -decay during delay time labeling 63 PLD imaging 63 21

Quantification too difficult? Use PC-MRI! Measure blood flow in the internal carotid arteries and calibrate perfusion maps based on a tissue segmentation of a 3D-T1 scan Aslan, et al. Magn Reson Med. 21 Mar;63(3):765-71 64 Is this all about quantification? No!! Think about: Dispersion of the bolus of labeled spins Dependency on cardiac cycle Motion artifacts Scanner problems (spikes, drift, instabilities) Intersubject differences Etc, etc, etc More research needed! 65 Acknowledgements Leiden University Medical Center Wouter Teeuwisse Sophie Schmid Xingxing Zhang Jeroen van der Grond Mark van Buchem University College London,UK Xavier Golay Amsterdam Medical Center, NL Sanna Gevers Aart Nederveen University Medical Center Utrecht Jeroen Hendrikse Reinoud Bokkers Esben Petersen UT Southwestern, Dallas, USA Hanzhang Lu Kiel University, Germany Michael Helle 66 66 22