NIH Public Access Author Manuscript Magn Reson Med. Author manuscript; available in PMC 2010 February 1.

Size: px
Start display at page:

Download "NIH Public Access Author Manuscript Magn Reson Med. Author manuscript; available in PMC 2010 February 1."

Transcription

1 NIH Public Access Author Manuscript Published in final edited form as: Magn Reson Med February ; 61(2): doi: /mrm The Effect of Inflow of Fresh Blood on Vascular-spaceoccupancy (VASO) Contrast Manus J. Donahue 1,2,3, Jun Hua 1,2,4, James J. Pekar 1,2, and Peter C.M. van Zijl 1,2 1 The Russell H. Morgan Department of Radiology and Radiological Science, Division of MR Research, The Johns Hopkins University School of Medicine, Baltimore, MD USA 2 F.M. Kirby Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD USA 3 Oxford Centre for Functional MRI of the Brain, Department of Clinical Neurology, The University of Oxford, Oxford, UK 4 Department of Biomedical Engineering, The Johns Hopkins University School of Medicine, MD USA Abstract In vascular-space-occupancy (VASO)-MRI, cerebral blood volume (CBV) weighted contrast is generated by applying a non-selective inversion pulse followed by imaging when blood water magnetization is zero. An uncertainty in VASO relates to the completeness of blood water nulling. Specifically, radiofrequency coils produce a finite inversion volume, rendering the possibility of fresh, non-nulled blood. Here, VASO-fMRI was performed for varying inversion volume and TR using body coil radiofrequency transmission. For thin inversion volume thickness (δ tot <10 mm), VASO signal changes were positive (ΔS/S= %). Signal changes were negative and varied in magnitude for intermediate inversion volumes (δ tot = mm), yet did not differ significantly (P>0.05) for δ tot >300 mm. These data suggest that blood water is in steady-state for δ tot >300 mm. In this appropriate range, long-tr VASO data converged to a less negative value (ΔS/S= 1.4±0.2%) than short-tr data (ΔS/S= 2.2±0.2%), implying that cerebral blood flow or transit-state effects may influence VASO contrast at short TR. Keywords VASO; CBV; fresh blood; inflow; exchange Introduction Microvascular cerebral blood volume (CBV) is known to adjust during periods of increased neuronal activity (1 5). Such CBV changes have been reported to occur primarily in arterioles and capillaries (2), with a smaller change possibly occurring in venules as well (6). Since such CBV changes occur in the microvasculature and not large draining veins, identification of CBV adjustment concurrent to neuronal activity should be useful for improving the spatial localization of brain function over conventional blood-oxygenationlevel-dependent (BOLD)-fMRI (7,8). Vascular-space-occupancy (VASO) fmri (9) is gaining popularity as a method for noninvasively assessing CBV changes accompanying neuronal activity. In VASO, a Corresponding Author: Peter C.M. van Zijl, The Johns Hopkins University School of Medicine, Dept. of Radiology, 217 Traylor Bldg, 720 Rutland Ave, Baltimore, MD, 21205, pvanzijl@mri.jhu.edu Tel: , Fax:

2 Donahue et al. Page 2 Methods Theory spatially non-selective inversion pulse is applied, after which an image is acquired at an inversion time (TI) when the longitudinal magnetization (M z ) of blood is expected to be zero, yet M z of tissue is positive. Typically, a negative VASO-fMRI signal change (ΔS/S) is observed during increased neuronal activity, which has been attributed to a decrease in the detectable tissue signal consequential to the CBV increase (9). Experimental data in humans (9,10) have confirmed VASO localization to gray matter parenchyma, while recent highresolution data in cats (11) indicate localization of VASO contrast to the middle cortical layer, in agreement with CBV approaches using paramagnetic agents. However, similar to other fmri methods, VASO has been criticized for uncertainty regarding the nature of its contrast mechanism. The most important question relates to the contribution of intravascular blood water that is not nulled. Potential causes of this could be exchange between capillary blood water and tissue water (9,12), as well as inflow of fresh (i.e. non-nulled) blood into the image slices. Although a body-coil and adiabatic inversion have been used in VASO applications until now (9,12 14), the width of the inversion volume may differ per instrument and may allow for some fresh blood, which is not in steady-state and therefore not nulled, to enter the imaging volume before acquisition. It has previously been simulated that such fresh blood will cause VASO ΔS/S to become more negative (10). Here, VASO ΔS/S is measured as a function of inversion volume thickness to assess how fresh blood may influence VASO contrast. In VASO, a spatially non-selective inversion pulse is applied to invert all proton magnetization, after which an image is acquired at a TI when longitudinal blood magnetization is expected to be zero. Since tissue water T 1 ( ms at 3.0T (13)) is shorter than blood water T 1 ( ms at 3.0T (14)), the extravascular tissue signal will be slightly positive at TI. Multiple VASO images can be acquired in a time-efficient manner if a repetition time (TR) shorter than the amount of time required for tissue magnetization to recover to equilibrium is used. In this case, tissue and blood are presumed to be in steadystate and the TI can be adjusted to keep the steady-state blood water magnetization nulled. In the cerebral cortex, the VASO signal is proportional to the gray matter parenchymal signal (S par ), which comprises the extravascular tissue (t) and microvascular blood (b) and is assumed to change between a baseline (base) and vasodilatory (act) state: where i = activated (act) or base. When using a gradient echo sequence, the tissue signal is given by, where C par 0.89 ml water/ml parenchyma (15) is the water density of gray matter parenchyma, M t is the longitudinal magnetization of extravascular tissue, TE is the echo time and T 2,t * 45.3 ms (base) or 46.6 (act) are the effective transverse relaxation times for extravascular tissue as reported in the literature (13). For blood, relaxation times will vary with microvascular compartment. Assuming that an MR voxel comprises 21% arterioles, (1) (2)

3 Donahue et al. Page 3 33% capillary and 46% venules (8), the blood compartment can be approximated as 38% arteriolar (a) and 62% venular (v), where i=act or base. Eq. 3 assumes that the CBV change may occur in either the arterioles or venules. C b 87 ml water/ml blood is the water density of blood (16). Assuming a microvascular Hct 37 (10), the transverse relaxation times for blood can be calculated according to T 2 *=[A*+B*(1-Y) +C*(1-Y) 2 ] 1 (17,18) where A*=16.6 s 1, B*=37.3 s 1 and C*=99.6 s 1 (which have been extrapolated from recent work in bovine blood (18)). Assuming arteriolar and venular oxygen saturation fractions (Y) of 0.98 and 0.61, respectively, the transverse relaxation times for blood are found to be 57.6 ms (arterioles) and 21.6 ms (venules). The total VASO signal change (ΔS/S) in such a functional experiment is:. It has commonly been assumed that all blood water in the VASO experiment is nulled and Eq. 3 vanishes (9). However, this is only true for steady-state (ss) blood water and even here this is an approximation since blood T 1 varies between microvascular compartments. In practice, the inversion volume of the body coil is finite, which may lead to inflow of some fresh (i.e. non-steady-state) blood and up to two additional magnetic situations for the blood water. First, if TR is longer than the time to refresh blood, blood water magnetization will appear as being fully relaxed and, instead of a multi-inversion steady state, experience only a single inversion pulse in each scan. This so-called fully-relaxed (f-r) blood will flow into the imaging slice and will have non-zero magnetization at the TI calculated for steady-state blood-nulling. Second, for thin inversion volumes, a fraction of blood in the imaging slice may be completely refreshed; this blood will have magnetization that is the same as at equilibrium (eq). Therefore, longitudinal blood magnetization can be expanded: where j=arteriole or venule. These magnetizations relate to the equilibrium magnetization (M 0 ) via, (3) (4) (5) (6) (7), and

4 Donahue et al. Page 4 (8) Experiment. The inversion pulse will always invert the imaging slice, and therefore the tissue signal will be in steady-state,. T 1 refers to the longitudinal relaxation time, which is taken to be 1209 ms for tissue (19), 1747 ms for arterioles and 1703 ms for venules at a field strength of 3.0T. Arteriolar and venular T 1 are slightly higher than those used in previous work at the same field strength ( ms (10,13)); this is because here we improve the specificity by using microvascular T 1, corresponding to a Hct 37 and varying oxygenation status (98% for arterioles and 61% for venules) whereas previous work used a larger Hct 44, corresponding to larger vessels. To understand the influence of residual microvascular blood water, simulations were performed using the optimal TI calculated for macrovascular blood water nulling (T 1,b =1627 ms); this allows for better interpretation of the currently used approaches in the literature. The body coil length of the scanner used in these experiments is 650 mm, which was confirmed by the local MR engineer. Therefore an adiabatic pulse is expected to invert no less than this length. A magnetic field gradient associated with the adiabatic inversion was introduced to allow for a finite volume thickness (δ tot ) of water to be inverted. To test maximal inversion thicknesses with respect to inflowing blood, the imaging slice was not positioned in the center of the coil, but toward the top with the isocenter of the coil centered approximately 1 cm inferior to the volunteer s mouth. VASO-fMRI experiments were performed for a non-selective inversion pulse (δ tot 650 mm), as well as for δ tot =10, 100, 200, 300, 400, 500, and 600 mm, separately at a short TR (2s) and a long TR (5s). These 16 experiments were pseudo-randomized and repeated on five healthy volunteers (age: 31±6 yrs), all of whom provided informed, written consent to an IRB-approved protocol in accordance with HIPAA guidelines. Scan parameters: Philips 3.0T MR scanner (Philips, Best, The Netherlands), mm 3 nominal spatial resolution, FOV = mm 2, single-shot gradient echo EPI, TE = 12.7 ms, SENSE-factor = 2.5, TR/TI=2000/711 ms or TR/TI=5000/1054 ms, as based on T 1,b = 1627ms. All slices were co-registered and motion corrected using the FSL Linear Image Registration Toolkit (FLIRT) (20). Subsequently, images were corrected for baseline drift using a cubic spline interpolation algorithm. Slices were reconstructed and zero-filled to a matrix of The fmri paradigm consisted of 30s/30s on/off cross-hair fixation/flashing checkerboard (8 Hz) repeated three times. An additional 30s of data was acquired before the paradigm block began to allow for blood magnetization to reach a steady-state; data acquired during this period were not analyzed. Positive and negative VASO ΔS/S were calculated from voxels in the occipital cortex meeting activation criteria in a z-hypothesis test; negative activation criteria were: z 3 (P<0.05), SNR 20, cluster size 4. Positive activation criteria were identical, except with z 3. Time courses were calculated for each δ tot scan for voxels meeting negative activation criteria in the non-selective VASO experiment. This assured (9)

5 Donahue et al. Page 5 Results Simulations Experiment that common voxels were analyzed in all scans. It should be noted that this voxel selection method controls for partial volume effects between scans. Significance of ΔS/S variation between δ tot values or TR values was based on a paired t-test with significance defined as P<0.05. Finally, number of voxels meeting positive (z 3) or negative (z 3) activation criteria in each scan were separately recorded in order to understand how the proportion of voxels showing positive or negative signal changes was influenced by inversion volume. The magnitude of different blood magnetizations (Fig. 1a) is simulated as a function of TR. Blood water in equilibrium has a constant magnetization, as expected based on Eq. 7, yet fully-relaxed blood water magnetization is more negative at short TR (Eq. 8). Steady-state blood water magnetization is nearly nulled at all TR values, as is assumed in the VASO literature. Steady-state blood magnetization, however, is not completely nulled (residual magnetization 2%) since the nulling time (TI) was based on the macrovascular blood T 1,b =1627 ms, as is the case in current VASO studies, which differs appreciably for the arteriolar and venular blood magnetization at Hct =0.37 (1747 and 1704 ms, respectively). Tissue magnetization increases with TR, as expected based on steady-state considerations. In Fig. 1b, the influence of different blood magnetizations on VASO ΔS/S is shown assuming arteriolar CBV changes. VASO ΔS/S is simulated assuming three conditions: 100% equilibrium blood, 100% fully-relaxed blood and 100% steady-state blood. The voxel will likely contain a mixture of each of these blood types; Fig. 1b provides only an overview of how the different blood types will influence the contrast. For equilibrium blood, VASO ΔS/S is positive, becoming smaller at long TR due the exponential decay of the steady-state tissue magnetization. Here, the intravascular blood water BOLD signal change (Eq. 3) dominates over the extravascular blood volume change in the tissue signal term (Eq. 2). For fully-relaxed blood water, VASO ΔS/S is more negative at short TR than at long TR. This is because the fully-relaxed blood null time (TI 126 ms) is closer to the steady-state blood water null time at long TR (TI 054 ms) than that at short TR (TI 11 ms). Finally, for steady-state blood water, VASO ΔS/S is found to be approximately 1.6% and relatively independent of TR. Fig. 1c shows simulation results assuming the same CBV change occurs in the venules (as opposed to arterioles). Notice that the general trends are the same, however the absolute numbers are slightly smaller with respect to absolute magnitude of the signal change. It is important to realize that in some situations, blood may be in a transit-state, when it is neither in equilibrium, fully-relaxed nor at steady-state. Such a transit-state may exist when blood water begins having one magnetization condition (e.g. equilibrium) and ends with another (e.g. steady-state) and may persist for several TR periods. Fig. 2 shows longitudinal blood magnetization as a function of time for TR=2s (a) and TR=5s (b) VASO experiments. Note that for TR=2s, it takes approximately three inversions before blood is in steady-state. For TR=5s VASO experiments, the transit-state is nearly undetectable due to the much longer times between inversion pulses. The simulations here were performed assuming all blood magnetization experiences an inversion pulse and no excitation pulse, which is true for the majority of blood in single-slice experiments when non-selective inversion pulses are used. Fig. 3a shows how the VASO inversion thickness (δ tot, blue + red) was varied experimentally. Note that the inversion was centered at the imaging slice (yellow); therefore,

6 Donahue et al. Page 6 Discussion the distance below the slice (δ in, red), which is relevant to inflowing arterial blood water, is half of δ tot. Representative z-maps for short and long TR for a single subject are shown for varying δ in (Fig. 3b); all inversion values are within the range of the coil, especially with the slice positioned higher in the coil. Note that the slices for short and long TR are slightly different since the two scans were performed at different times; we found that dividing the experiment into two sessions allowed for better volunteer compliance over the long fmri paradigm (e.g. two sessions of eight fmri scans vs. one session of 16 fmri scans). For small δ in =5 mm, the visual cortex shows primarily positive z, indicating that the voxels contain largely equilibrium blood. Fig. 3c shows ΔS/S as a function of δ in for the two TR values studied. Signal changes represent the same subset of voxels, which met the negative activation criteria in the nonselective VASO experiment (see Methods). ΔS/S traverses three regions (I III). In region I (5 mm δ in 50 mm), mean ΔS/S (n = 5) is positive at small inversion widths and becomes negative when increasing the thickness of the slab. In region II (50 mm < δ in 150 mm), ΔS/S becomes more negative at short TR, while it plateaus at long TR. In region III (δ in > 150 mm), ΔS/S does not change significantly (P>0.05). In region III, ΔS/S was statistically more negative at TR=2s than at TR=5s (P<0.05). Fig. 3d shows a surface map for a representative subject which depicts the relationship between the time, δ in, and ΔS/S for TR=2s. In all three task periods, ΔS/S is most negative for small δ in (dark blue) and becomes approximately equal in all task periods for δ in >150 mm. Table 1 shows the number of voxels meeting activation criteria in each scan and also compares VASO ΔS/S for the two repetition times used. Note that for both short and long TR, the thin inversion widths contain many positively activated voxels due to equilibrium blood contributions, whereas the thick inversion volumes contain consistently more negatively activated voxels. The proportion of negatively activated to positively activated voxels was not statistically different (P>0.05) between TR periods at any δ in value. However, more voxels meeting both negative and positive activation criteria were found at short TR. The P value corresponding to the significance between the short and long TR ΔS/S is shown (*). ΔS/S is more negative at short TR than at long TR, an observation that is most significant (P<0.05) at δ in =100 mm due to fully-relaxed blood contributions, but is also significant (P<0.05) for δ in 200 mm. It should be noted that the transition from δ in =100 mm to δ in =150 mm is the last statistically significant transition, as VASO signal changes for larger inversion volumes are non-distinguishable at a P value of When assessing whether the measured ΔS/S at a certain δ in value is significantly different from the ΔS/S measured at the thinner δ in value (#), no significant change is observed for δ in 100 mm, with the highest P values generally being in region III. The proportions of fresh and steady-state blood in VASO experiments The data presented here demonstrate how VASO contrast is influenced by non-nulled intravascular blood water contributions due to the inflow of fresh (equilibrium and/or fullyrelaxed) blood. Simulations predict two counteracting effects. First, contributions from fresh equilibrium blood will cause VASO ΔS/S to become positive, with this effect being largest at short TR. Second, fresh fully-relaxed blood will cause VASO ΔS/S to become more negative, but only at short TR where the null times for steady-state and fully-relaxed blood vary. The experimental short-tr ΔS/S trends as a function of inversion volume thickness therefore provide important clues regarding the relative extent of these two different blood magnetizations in the total VASO signal. Specifically, in region I, for δ in =5 mm, mean VASO ΔS/S values are 2.6±2% and 2.1±2% at TR=2s and TR=5s, respectively. These consistent positive values indicate that equilibrium blood is dominating for this thinnest

7 Donahue et al. Page 7 inversion volume. As can be seen in Fig. 3b and Table 1, positive and negative ΔS/S varies with voxel location, indicating that the amount of fully-relaxed and equilibrium blood varies spatially. In region II, VASO ΔS/S becomes more negative indicating that the CBV contribution to the VASO effect dominates. However, a large difference between short and long TR can be seen, indicating that fully-relaxed blood contributions are dominating for short TR. When small coils are used, it is possible that VASO ΔS/S will be more negative at short TR due to this limitation. In region III (δ in >150 mm), ΔS/S approximately plateaus (P>0.05) owing to the fraction of fully-relaxed blood decreasing and the fraction of effectively nulled, steady-state blood increasing. Therefore, these data suggest that a volume of mm below the imaging slice should be sufficient for steady-state conditions of blood nulling to hold. In order to control for partial volume effects between scans, common voxels were analyzed for each inversion volume VASO scan (see Methods) and mean signal change within these voxels was recorded. In theory, such an approach could give an inaccurate view of the signal changes if equal number of positive and negative signal changes are occurring within the voxels, yielding an overall small net signal change. However, we observed largely positive signal changes at thin inversion volumes and largely negative signal changes at thick inversion volumes, as can be seen in Fig. 3b and Table 1. The only inversion volume where approximately equal amounts of positively activated and negatively activated voxels were found was for δ in =50 mm, where significant amounts of both equilibrium and fully-relaxed blood were presumed to be present. This counteracting effect was most pronounced at short TR (Table 1) since fully-relaxed blood water contributions are more significant at short TR. As was shown in Fig. 2, it is possible for blood magnetization to occupy a transit-state, in which magnetization is not fully-relaxed, in equilibrium, or in steady-state. Furthermore, it was shown that this transit-state is more significant at short TR than at long TR. In the present experiments, data acquired during the first 30s were not analyzed, thereby allowing for blood magnetization to reach a potential steady-state. Such a waiting time is very important in VASO experiments and VASO data acquired using only one or two measurements, especially at short TR, should be interpreted with caution. It is of interest to note that, even when deleting data acquired during the first period, transit effects could occur when the steady-state changes during brain activation. These effects are presumably small because CBV changes are expected to occur locally. However, changes in blood velocity may slightly affect the presumed steady-state. Importantly, when blood water cannot reach a steady-state due to thin inversion volumes, the transit-state may persist for a much longer period, and will depend complexly on slice position, inversion volume, blood velocity and anatomical variation. As is shown in Fig. 2, one way to minimize such transitstate effects is by imaging at long TR. Similarly, fully-relaxed blood contributions can be minimized by imaging at long TR, as was demonstrated in Fig. 3c. Therefore, to desensitize VASO contrast to transit-state and fresh blood uncertainties, long TR (e.g. TR=5s) acquisitions are recommended. Given that it takes approximately three inversions for blood to reach steady-state in a TR=2s VASO experiment (Fig. 2), it is important to consider the mean velocity of blood within the typical VASO inversion volume (δ in =300 mm). Note that the above steady-state condition requires two inversions after the initial inversion, meaning that only 4s is required after the initial inversion for blood to reach steady-state. Therefore, the mean velocity of inflowing blood must be less than 75 mm/s. Flow velocity will vary significantly between inflowing vascular compartments (e.g. arteries, arterioles and capillaries), depending on diameter. Blood velocity in large arteries is approximately mm/s (5 10 mm diameter), falling to mm/s in smaller arteries (~1 mm diameter), 1 10 mm/s in arterioles ( µm diameter), and 0.7 mm/s in capillaries (see Piecknik et al. (21) and references therein). Using

8 Donahue et al. Page 8 a multi-compartment vascular tree model, it has been proposed that it takes approximately 4 5s for blood in large inflowing vessels (10 mm diameter) to reach the capillary exchange site. The precise velocity and inflow time is complex since the vascular tree contains an array of vessel sizes and orientations; also, plasma and red blood cells have different flow velocities, and both will contain water protons. Therefore, the range of velocities for intravascular blood water will clearly vary. Recently, using arterial spin labeling with multiple inversion times, it was shown that occipital arterial arrival time is longer than mean arterial arrival time in cerebral cortex (22); these results are in agreement with PET literature which has shown that mean transit time in occipital cortex is longer than in most other cortical regions (23). Therefore, it is more likely that blood will be in steady-state in visual experiments, such as were conducted here, than in other fmri experiments using motor or auditory stimuli. It may be noticed that there is an apparent slight upward trend in Fig. 3c, suggesting that if inversion volumes were increased beyond what is possible with standard body coils, the TR=2s signal change would converge to the TR=5s signal change. However, a statistical test (Table 1) shows no significant difference between consecutive signal change measurements over the range δ in = ; therefore, at present it can only be claimed that although there appears to be an upward trend, it is not significant. An additional uncertainty relates to which value for T 1 of blood water is correct to use when calculating the blood nulling TI. Here, it was shown that for steady-state blood water, microvascular blood magnetization is small ( 2%; Fig. 1a) when T 1 for macrovascular blood water is used to calculate TI. The present study used only a single TI value, and therefore it is not possible to say how VASO signal changes will vary experimentally with choice of TI. Assuming that a given voxel contains a mixture of arteriolar, capillary and venular blood, it is reasonable to assume that a TI calculated from the average macrovascular T 1 is a reasonable choice. However, as higher resolution VASO fmri becomes available and vasodynamics of different microvascular compartments are more fully understood, it is likely that VASO experiments may be employed with TI specific to different microvascular compartments. This would be more possible at higher magnetic fields, where the difference between arterial and venous blood T 1 is expected to increase if the same trend for oxygenation dependence holds as between 1.5T and 3T (14). Additional contributions to VASO contrast These data demonstrate how inflow of non-nulled blood water influences VASO contrast. However, two additional effects should be considered. First, partial volume contributions from CSF (5 15%) will cause VASO ΔS/S to become slightly more negative at long TR than at short TR (10). However, this contribution is small and will influence both short and long TR VASO ΔS/S, and therefore cannot fully account for the discrepancy observed between short and long TR VASO ΔS/S at δ in = mm. As shown in previous work, this discrepancy may be due to a second effect, namely changes in tissue M z consequential to exchange between the blood water spins and tissue water spins, similar to arterial spin labeling (ASL). This ASL effect, which has been shown to make VASO ΔS/S more negative (12,24), is most pronounced at short TR. This CBF influence to VASO contrast may provide a basis for future experiments to extract this important hemodynamic parameter, concurrently with CBV, from VASO data (24). This extraction of physiological parameters is not trivial as the exchange between capillary blood and tissue may also affect blood nulling. Future work should aim to understand such complex exchange effects in VASO contrast. To successfully accomplish this, it will be necessary to generate multicompartment vascular models which account for vascular dilatation, in addition to exchange effects within the capillary compartment.

9 Donahue et al. Page 9 Experimental limitations Conclusions Acknowledgments References Several experimental limitations should be noted. First, a single slice through the visual cortex was analyzed here, as is the case in many VASO-fMRI studies (9,10). For VASOfMRI performed in other brain regions, the local vascular geometry may cause the arrival time for fully-relaxed and equilibrium blood contributions to differ. Second, a body coiladministered adiabatic inversion is expected to invert a length no less than the length of the body coil. Here, the maximum inversion volume used was δ tot =600 mm, which is less than the length of the current body coil (δ tot =650 mm). However, body coil length will vary with scanner and vendor and care should be taken in performing VASO measurements when using smaller body coils or head coils for RF administration. Finally, T 1 varies considerably between blood compartments; therefore, the choice of null time will influence the amount of residual blood signal that remains from different blood compartments, however, as noted above, this residual blood magnetization is expected to be small. This work shows how VASO signal changes may vary with the thickness of the inversion volume and suggests that for sufficiently large body coils (δ tot 300 mm), VASO ΔS/S is independent of inversion volume thickness, implicating that intravascular blood water is in steady-state and largely nulled. Secondly, at such thick inversion volumes, a discrepancy between short and long TR VASO ΔS/S persists, indicating that additional effects, such as exchange between capillary blood and tissue or transit-state effects may alter VASO contrast. Care should be taken when interpreting VASO ΔS/S on smaller body coil systems, or when head coils are used for transmission, due to possible inflow of fresh blood. A simple way to minimize the effect of fully-relaxed blood and transit-state uncertainties in VASO contrast is to image at long TR, where the equilibrium and steady-state blood null times are more similar than at short TR. The authors are grateful to Terri Brawner, Kathleen Kahl, Ivana Kusevic, Joe Gillen, and Craig Jones for experimental assistance. This publication was made possible in part by a grant from the National Center for Research Resources (NCRR), a component of the National Institutes of Health (NIH). Its contents are solely the responsibility of the authors and do not necessarily represent the official view of NCRR or NIH. Dr. van Zijl is a paid lecturer for Philips Medical Systems. This arrangement has been approved by Johns Hopkins University in accordance with its conflict of interest policies. Grant support: NIH-NIBIB R01-EB004130, NIH-NCRR P41-RR15241, 1. Peppiatt CM, Howarth C, Mobbs P, Attwell D. Bidirectional control of CNS capillary diameter by pericytes. Nature. 2006; 443(7112): [PubMed: ] 2. Hillman EM, Devor A, Bouchard MB, Dunn AK, Krauss GW, Skoch J, Bacskai BJ, Dale AM, Boas DA. Depth-resolved optical imaging and microscopy of vascular compartment dynamics during somatosensory stimulation. Neuroimage. 2007; 35(1): [PubMed: ] 3. Phillis, JW. The Regulation of cerebral blood flow. Boca Raton: CRC Press; p. 4. Iadecola C. Regulation of the cerebral microcirculation during neural activity: is nitric oxide the missing link? Trends Neurosci. 1993; 16(6): [PubMed: ] 5. Kuschinsky W. Coupling of blood flow and metabolism in the brain. J Basic Clin Physiol Pharmacol. 1990; 1(1 4): [PubMed: ] 6. Mandeville JB, Marota JJ, Ayata C, Zaharchuk G, Moskowitz MA, Rosen BR, Weisskoff RM. Evidence of a cerebrovascular postarteriole windkessel with delayed compliance. J Cereb Blood Flow Metab. 1999; 19(6): [PubMed: ]

10 Donahue et al. Page Ogawa S, Lee TM, Kay AR, Tank DW. Brain magnetic resonance imaging with contrast dependent on blood oxygenation. Proc Natl Acad Sci U S A. 1990; 87(24): [PubMed: ] 8. van Zijl PC, Eleff SM, Ulatowski JA, Oja JM, Ulug AM, Traystman RJ, Kauppinen RA. Quantitative assessment of blood flow, blood volume and blood oxygenation effects in functional magnetic resonance imaging. Nat Med. 1998; 4(2): [PubMed: ] 9. Lu H, Golay X, Pekar JJ, Van Zijl PC. Functional magnetic resonance imaging based on changes in vascular space occupancy. Magn Reson Med. 2003; 50(2): [PubMed: ] 10. Donahue MJ, Lu H, Jones CK, Edden RA, Pekar JJ, van Zijl PC. Theoretical and experimental investigation of the VASO contrast mechanism. Magn Reson Med. 2006; 56(6): [PubMed: ] 11. Jin T, Kim SG. Improved cortical-layer specificity of vascular space occupancy fmri with slab inversion relative to spin-echo BOLD at 9.4 T. Neuroimage In press. 12. Donahue MJ, Lu H, Jones CK, Pekar JJ, van Zijl PC. An account of the discrepancy between MRI and PET cerebral blood flow measures. A high-field MRI investigation. NMR Biomed. 2006; 19(8): [PubMed: ] 13. Lu H, van Zijl PC. Experimental measurement of extravascular parenchymal BOLD effects and tissue oxygen extraction fractions using multi-echo VASO fmri at 1.5 and 3.0 T. Magn Reson Med. 2005; 53(4): [PubMed: ] 14. Lu H, Clingman C, Golay X, van Zijl PC. Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla. Magn Reson Med. 2004; 52(3): [PubMed: ] 15. Lu H, Golay X, van Zijl PC. Intervoxel heterogeneity of event-related functional magnetic resonance imaging responses as a function of T(1) weighting. Neuroimage. 2002; 17(2): [PubMed: ] 16. Herscovitch P, Raichle ME. What is the correct value for the brain--blood partition coefficient for water? J Cereb Blood Flow Metab. 1985; 5(1): [PubMed: ] 17. Wright GA, Hu BS, Macovski A. I.I. Rabi Award. Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T. J Magn Reson Imaging. 1991; 1(3): [PubMed: ] 18. Zhao JM, Clingman CS, Narvainen MJ, Kauppinen RA, van Zijl PC. Oxygenation and hematocrit dependence of transverse relaxation rates of blood at 3T. Magn Reson Med. 2007; 58(3): [PubMed: ] 19. Lu H, Nagae-Poetscher LM, Golay X, Lin D, Pomper M, van Zijl PC. Routine clinical brain MRI sequences for use at 3.0 Tesla. J Magn Reson Imaging. 2005; 22(1): [PubMed: ] 20. Jenkinson M, Smith S. A global optimisation method for robust affine registration of brain images. Med Image Anal. 2001; 5(2): [PubMed: ] 21. Piechnik SK, Chiarelli PA, Jezzard P. Modelling vascular reactivity to investigate the basis of the relationship between cerebral blood volume and flow under CO2 manipulation. Neuroimage. 2008; 39(1): [PubMed: ] 22. Macintosh BJ, Pattinson KT, Gallichan D, Ahmad I, Miller KL, Feinberg DA, Wise RG, Jezzard P. Measuring the effects of remifentanil on cerebral blood flow and arterial arrival time using 3D GRASE MRI with pulsed arterial spin labelling. J Cereb Blood Flow Metab Leenders KL, Perani D, Lammertsma AA, Heather JD, Buckingham P, Healy MJ, Gibbs JM, Wise RJ, Hatazawa J, Herold S, et al. Cerebral blood flow, blood volume and oxygen utilization Normal values and effect of age. Brain. 1990; 113(Pt 1): [PubMed: ] 24. Donahue, MJ.; van Laar, PJ.; Hendrikse, J.; van Zijl, PC. Determination of CBF and CBV using Short and Long TR Vascular Space Occupancy (VASO)-MRI; 15th Annual International Society for Magnetic Resonance in Medicine; Berlin: 2007.

11 Donahue et al. Page 11 Figure 1. (a) Simulations depicting the TR-dependence of two possible fresh blood contributions, namely equilibrium (eq) and fully-relaxed (f-r) blood water magnetizations. The steady-state (ss) blood and tissue magnetizations are also shown. (b) Simulation showing the effect of three separate cases: pure equilibrium (x eq =1), fully-relaxed (x f-r =1) and steady-state (x ss =1) blood water magnetization on VASO signal change (ΔS/S) using CBV base = 0.05 ml/ml, CBV act = 0.07 ml/ml. All change is assumed to originate from the arteriolar compartment. (c) Simulation showing the same three magnetization cases, except with vasodilatation assumed to originate in the venular compartment.

12 Donahue et al. Page 12 Figure 2. (a) Simulated blood magnetization in a TR=2s VASO experiment. Note that the blood magnetization does not reach steady state for approximately three inversion cycles. In the first TR period, the blood is fully-relaxed; however, in the next two TR periods it is in a transit-state, where it is neither fully-relaxed nor in steady-state. After the third TR period, the blood magnetizatiton is in steady-state. (b) Simulated blood magnetization in a TR=5s VASO experiment. Note that here the transit-state is nearly undetectable. The vertical dashed lines depict the expected blood nulling times assuming steady-state blood magnetization (711 ms after inversion at TR=2s and 1054 ms after inversion for TR=5s).

13 Donahue et al. Page 13 Figure 3. (a) Location of the VASO imaging slice (yellow) and corresponding total inversion slab thickness (δ tot ) which was varied; δ in (red) shows the inversion volume relevant to inverting inflowing arterial blood water. (b) Representative z-maps for a single subject for TR=2s (above) and TR=5s (below). Note that for small δ in =5 mm, activation (z) in the occipital cortex is largely positive, whereas it is primarily negative for larger δ in. (c) The effect of the inversion volume thickness (δ in ) on VASO signal changes (ΔS/S). Values are mean ±standard error (n=5). Three regions are demarcated. Region I likely contains significant fractions of fully-relaxed and equilibrium blood, region II contains a mixture of fullyrelaxed and steady-state blood and region III contains blood that is primarily in steady-state. (d) A surface plot showing the effect of δ in on VASO ΔS/S for the three separate task periods for a representative subject. Notice that the signal changes plateau to approximately the same value consistently in each of the three paradigm blocks.

14 Donahue et al. Page 14 Table 1 VASO activated voxels, signal changes (ΔS/S) and P values as a function of inflowing inversion volume thickness (δ in ). Activated Voxels ΔS/S (%) P TR2 vs TR5 * P δin vs δin-before # Positive Negative δ in (mm) TR=2s TR=5s TR=2s TR=5s TR=2s TR=5s TR=2s TR=5s 5 507±87 619±52 99±41 27±3 2.6± ± ±89 321±41 265±90 77±20 1.7± ± < ±45 32±6 352±97 133±31 2.8± ±0.3 < ±23 78±34 317±87 248±23 2.4± ± ±22 65±43 368±96 185±35 2.3± ± ±28 39±2 258±85 195±43 2.1± ± ±30 51±16 332±46 227± ± ± Activated voxels and signal changes (ΔS/S) represent the mean over five subjects ±standard error. * Significance of difference between ΔS/S measured at TR=2s and TR=5s for the given δ in. # Significance of a given ΔS/S having the same sample mean as ΔS/S from the previous δ in measurement. Changes that are significant at P<0.05 are italicized.

PHYSICS OF MRI ACQUISITION. Alternatives to BOLD for fmri

PHYSICS OF MRI ACQUISITION. Alternatives to BOLD for fmri PHYSICS OF MRI ACQUISITION Quick Review for fmri HST-583, Fall 2002 HST.583: Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Harvard-MIT Division of Health Sciences and Technology

More information

Functional Magnetic Resonance Imaging Based on Changes in Vascular Space Occupancy

Functional Magnetic Resonance Imaging Based on Changes in Vascular Space Occupancy Magnetic Resonance in Medicine 50:263 274 (2003) Functional Magnetic Resonance Imaging Based on Changes in Vascular Space Occupancy Hanzhang Lu, 1 3 * Xavier Golay, 1,3 James J. Pekar, 1,3 and Peter C.M.

More information

Daniel Bulte. Centre for Functional Magnetic Resonance Imaging of the Brain. University of Oxford

Daniel Bulte. Centre for Functional Magnetic Resonance Imaging of the Brain. University of Oxford Daniel Bulte Centre for Functional Magnetic Resonance Imaging of the Brain University of Oxford Overview Signal Sources BOLD Contrast Mechanism of MR signal change FMRI Modelling Scan design details Factors

More information

Basics of Quantification of ASL

Basics of Quantification of ASL Basics of Matthias van Osch Contents Thoughts about quantification Some quantification models Bloch equations Buxton model Parameters that need to be estimated Labeling efficiency M Bolus arrival time

More information

Turbo ASL: Arterial Spin Labeling With Higher SNR and Temporal Resolution

Turbo ASL: Arterial Spin Labeling With Higher SNR and Temporal Resolution COMMUNICATIONS Magnetic Resonance in Medicine 44:511 515 (2000) Turbo ASL: Arterial Spin Labeling With Higher SNR and Temporal Resolution Eric C. Wong,* Wen-Ming Luh, and Thomas T. Liu A modified pulsed

More information

DEVELOPMENT OF MRI TECHNIQUES FOR MEASURING CEREBRAL BLOOD VOLUME, BLOOD FLOW, AND BLOOD OXYGENATION WITHIN A SINGLE SCAN

DEVELOPMENT OF MRI TECHNIQUES FOR MEASURING CEREBRAL BLOOD VOLUME, BLOOD FLOW, AND BLOOD OXYGENATION WITHIN A SINGLE SCAN DEVELOPMENT OF MRI TECHNIQUES FOR MEASURING CEREBRAL BLOOD VOLUME, BLOOD FLOW, AND BLOOD OXYGENATION WITHIN A SINGLE SCAN by Ying Cheng A dissertation submitted to Johns Hopkins University in conformity

More information

Functional Magnetic Resonance Imaging with Arterial Spin Labeling: Techniques and Potential Clinical and Research Applications

Functional Magnetic Resonance Imaging with Arterial Spin Labeling: Techniques and Potential Clinical and Research Applications pissn 2384-1095 eissn 2384-1109 imri 2017;21:91-96 https://doi.org/10.13104/imri.2017.21.2.91 Functional Magnetic Resonance Imaging with Arterial Spin Labeling: Techniques and Potential Clinical and Research

More information

Functional MRI with Magnetization Transfer Effects: Determination of BOLD and Arterial Blood Volume Changes

Functional MRI with Magnetization Transfer Effects: Determination of BOLD and Arterial Blood Volume Changes Functional MRI with Magnetization Transfer Effects: Determination of BOLD and Arterial Blood Volume Changes Tae Kim, 1 * Kristy Hendrich, 1 and Seong-Gi Kim 1,2 Magnetic Resonance in Medicine 60:1518 1523

More information

Hemodynamics and fmri Signals

Hemodynamics and fmri Signals Cerebral Blood Flow and Brain Activation UCLA NITP July 2011 Hemodynamics and fmri Signals Richard B. Buxton University of California, San Diego rbuxton@ucsd.edu... The subject to be observed lay on a

More information

Publication for the Philips MRI Community Issue 39 December 2009

Publication for the Philips MRI Community Issue 39 December 2009 FieldStrength Publication for the Philips MRI Community Issue 39 December 2009 32-channel coil boosts 3.0T neuro imaging at Kennedy Krieger Kennedy Krieger Institute sees significantly better fmri, DTI,

More information

Hemodynamics and fmri Signals

Hemodynamics and fmri Signals Cerebral Blood Flow and Brain Activation UCLA NITP July 2010 Hemodynamics and fmri Signals Richard B. Buxton University of California, San Diego rbuxton@ucsd.edu... The subject to be observed lay on a

More information

Improved cortical-layer specificity of vascular space occupancy fmri with slab inversion relative to spin-echo BOLD at 9.4 T

Improved cortical-layer specificity of vascular space occupancy fmri with slab inversion relative to spin-echo BOLD at 9.4 T www.elsevier.com/locate/ynimg NeuroImage 40 (2008) 59 67 Improved cortical-layer specificity of vascular space occupancy fmri with slab inversion relative to spin-echo BOLD at 9.4 T Tao Jin a, and Seong-Gi

More information

BOLD signal compartmentalization based on the apparent diffusion coefficient

BOLD signal compartmentalization based on the apparent diffusion coefficient Magnetic Resonance Imaging 20 (2002) 521 525 BOLD signal compartmentalization based on the apparent diffusion coefficient Allen W. Song a,b *, Harlan Fichtenholtz b, Marty Woldorff b a Brain Imaging and

More information

Perfusion-Based fmri. Thomas T. Liu Center for Functional MRI University of California San Diego May 7, Goal

Perfusion-Based fmri. Thomas T. Liu Center for Functional MRI University of California San Diego May 7, Goal Perfusion-Based fmri Thomas T. Liu Center for Functional MRI University of California San Diego May 7, 2006 Goal To provide a basic understanding of the theory and application of arterial spin labeling

More information

Simultaneous Acquisition of Cerebral Blood Volume-, Blood Flow-, and Blood Oxygenation-Weighted MRI Signals at Ultra-High Magnetic Field

Simultaneous Acquisition of Cerebral Blood Volume-, Blood Flow-, and Blood Oxygenation-Weighted MRI Signals at Ultra-High Magnetic Field NOTE Magnetic Resonance in Medicine 00:00 00 (2014) Simultaneous Acquisition of Cerebral Blood Volume-, Blood Flow-, and Blood Oxygenation-Weighted MRI Signals at Ultra-High Magnetic Field Steffen N. Krieger,

More information

Biennial SPM course The BOLD signal. Cyril Pernet. Centre for Clinical Brain Sciences (CCBS) Neuroimaging Sciences

Biennial SPM course The BOLD signal. Cyril Pernet. Centre for Clinical Brain Sciences (CCBS) Neuroimaging Sciences Biennial SPM course 2017 The BOLD signal Cyril Pernet Centre for Clinical Brain Sciences (CCBS) Neuroimaging Sciences Overview 1. MRI physics 2. Neurovascular coupling 3. Neural activity and BOLD 4. Experimental

More information

ASL Perfusion Imaging: Concepts and Applications

ASL Perfusion Imaging: Concepts and Applications ASL Perfusion Imaging: Concepts and Applications David C. Alsop, Ph.D. Beth Israel Deaconess Medical Center and Harvard Medical School, Boston USA INTRODUCTION Arterial Spin Labeling (ASL) perfusion imaging

More information

MR Advance Techniques. Vascular Imaging. Class II

MR Advance Techniques. Vascular Imaging. Class II MR Advance Techniques Vascular Imaging Class II 1 Vascular Imaging There are several methods that can be used to evaluate the cardiovascular systems with the use of MRI. MRI will aloud to evaluate morphology

More information

Magnetic Resonance Angiography

Magnetic Resonance Angiography Magnetic Resonance Angiography 1 Magnetic Resonance Angiography exploits flow enhancement of GR sequences saturation of venous flow allows arterial visualization saturation of arterial flow allows venous

More information

Abstract. Introduction. Material and Methods. Results. Conclusion

Abstract. Introduction. Material and Methods. Results. Conclusion Dynamic susceptibility contrast MRI calibrated using T1-based steadystate CBV and vascular space occupancy (VASO): Comparison with model-free arterial spin labelling Emelie Lindgren Supervisors: Linda

More information

Field Strength. Regional Perfusion Imaging (RPI) matches cerebral arteries to flow territories

Field Strength. Regional Perfusion Imaging (RPI) matches cerebral arteries to flow territories Field Strength Changing how the world looks at MR. Regional Perfusion Imaging (RPI) matches cerebral arteries to flow territories Research groups in Utrecht, Baltimore and Singapore collaborate on this

More information

fmri: Interpretation, Limits and Potential Pitfalls

fmri: Interpretation, Limits and Potential Pitfalls fmri: Interpretation, Limits and Potential Pitfalls Seong-Gi Kim kimsg@pitt.edu www.kimlab.pitt.edu Mapping Brain Functions Stimulation/Task Functional Map (MRI) Pre-synaptic activity Post-synaptic activity

More information

The Low Sensitivity of Fluid-Attenuated Inversion-Recovery MR in the Detection of Multiple Sclerosis of the Spinal Cord

The Low Sensitivity of Fluid-Attenuated Inversion-Recovery MR in the Detection of Multiple Sclerosis of the Spinal Cord The Low Sensitivity of Fluid-Attenuated Inversion-Recovery MR in the Detection of Multiple Sclerosis of the Spinal Cord Mark D. Keiper, Robert I. Grossman, John C. Brunson, and Mitchell D. Schnall PURPOSE:

More information

INTRO TO BOLD FMRI FRANZ JOSEPH GALL ( ) OUTLINE. MRI & Fast MRI Observations Models Statistical Detection

INTRO TO BOLD FMRI FRANZ JOSEPH GALL ( ) OUTLINE. MRI & Fast MRI Observations Models Statistical Detection INTRO TO BOLD FMRI 2014 M.S. Cohen all rights reserved mscohen@g.ucla.edu OUTLINE FRANZ JOSEPH GALL (1758-1828) MRI & Fast MRI Observations Models Statistical Detection PAUL BROCA (1824-1880) WILLIAM JAMES

More information

Neurovascular Physiology and Pathophysiology

Neurovascular Physiology and Pathophysiology Neurovascular Physiology and Pathophysiology The physiological questions aim at understanding the molecular and biochemical mechanisms, by which the brain adapts local blood flow to neuronal activity and

More information

Cover Page. The handle holds various files of this Leiden University dissertation

Cover Page. The handle   holds various files of this Leiden University dissertation Cover Page The handle http://hdl.handle.net/1887/49562 holds various files of this Leiden University dissertation Author: Schmid, Sophie Title: Arterial spin labeling in space and time : new MRI sequences

More information

ASL BASICS II. Learning Objectives. Outline. Acquisition. M. A. Fernández-Seara, Ph. D. Arterial spin labeled perfusion MRI: basic theory

ASL BASICS II. Learning Objectives. Outline. Acquisition. M. A. Fernández-Seara, Ph. D. Arterial spin labeled perfusion MRI: basic theory Acquisition ASL BASICS II M. A. Fernández-Seara, Ph. D. Neuroimaging Laboratory Center for Applied Medical Research University of Navarra Pamplona, Spain Outline Arterial spin labeled perfusion MRI: basic

More information

PERFUSION MRI CONTRAST BASED TECHNIQUES

PERFUSION MRI CONTRAST BASED TECHNIQUES PERFUSION MRI CONTRAST BASED TECHNIQUES by Kenny K Israni Mar 28, 2006 PERFUSION - MRI Dynamic Susceptibility contrast Dynamic Relaxivity contrast STEADY-STATE STATE TECHNIQUES Steady-state Susceptibility

More information

Supplementary information Detailed Materials and Methods

Supplementary information Detailed Materials and Methods Supplementary information Detailed Materials and Methods Subjects The experiment included twelve subjects: ten sighted subjects and two blind. Five of the ten sighted subjects were expert users of a visual-to-auditory

More information

Functional MRI Mapping Cognition

Functional MRI Mapping Cognition Outline Functional MRI Mapping Cognition Michael A. Yassa, B.A. Division of Psychiatric Neuro-imaging Psychiatry and Behavioral Sciences Johns Hopkins School of Medicine Why fmri? fmri - How it works Research

More information

The physiology of the BOLD signal What do we measure with fmri?

The physiology of the BOLD signal What do we measure with fmri? The physiology of the BOLD signal What do we measure with fmri? Methods and Models in fmri, 10.11.2012 Jakob Heinzle Translational Neuromodeling Unit (TNU) Institute for Biomedical Engineering (IBT) University

More information

Group-Wise FMRI Activation Detection on Corresponding Cortical Landmarks

Group-Wise FMRI Activation Detection on Corresponding Cortical Landmarks Group-Wise FMRI Activation Detection on Corresponding Cortical Landmarks Jinglei Lv 1,2, Dajiang Zhu 2, Xintao Hu 1, Xin Zhang 1,2, Tuo Zhang 1,2, Junwei Han 1, Lei Guo 1,2, and Tianming Liu 2 1 School

More information

Titelmaster The physics of functional magnetic resonance imaging (fmri)

Titelmaster The physics of functional magnetic resonance imaging (fmri) Titelmaster The physics of functional magnetic resonance imaging (fmri) Outline 1.Introduction 2.The fmri experiment 2 3.The physics basis of fmri 4.Application Outline 3 1.Introduction Introduction Phrenology

More information

WHAT DOES THE BRAIN TELL US ABOUT TRUST AND DISTRUST? EVIDENCE FROM A FUNCTIONAL NEUROIMAGING STUDY 1

WHAT DOES THE BRAIN TELL US ABOUT TRUST AND DISTRUST? EVIDENCE FROM A FUNCTIONAL NEUROIMAGING STUDY 1 SPECIAL ISSUE WHAT DOES THE BRAIN TE US ABOUT AND DIS? EVIDENCE FROM A FUNCTIONAL NEUROIMAGING STUDY 1 By: Angelika Dimoka Fox School of Business Temple University 1801 Liacouras Walk Philadelphia, PA

More information

Vascular Filters of Functional MRI: Spatial Localization Using BOLD and CBV Contrast

Vascular Filters of Functional MRI: Spatial Localization Using BOLD and CBV Contrast Vascular Filters of Functional MRI: Spatial Localization Using BOLD and CBV Contrast Joseph B. Mandeville 1,2 * and John J.A. Marota 1,3 Magnetic Resonance in Medicine 42:591 598 (1999) The spatial distributions

More information

ORIGINAL ARTICLE. Jack A Wells 1, Bernard Siow 1,2, Mark F Lythgoe 1,4 and David L Thomas 3,4

ORIGINAL ARTICLE. Jack A Wells 1, Bernard Siow 1,2, Mark F Lythgoe 1,4 and David L Thomas 3,4 Journal of Cerebral Blood Flow & Metabolism (2013) 33, 215 224 & 2013 ISCBFM All rights reserved 0271-678X/13 $32.00 www.jcbfm.com ORIGINAL ARTICLE Measuring biexponential transverse relaxation of the

More information

Supplementary Online Content

Supplementary Online Content Supplementary Online Content Gregg NM, Kim AE, Gurol ME, et al. Incidental cerebral microbleeds and cerebral blood flow in elderly individuals. JAMA Neurol. Published online July 13, 2015. doi:10.1001/jamaneurol.2015.1359.

More information

P2 Visual - Perception

P2 Visual - Perception P2 Visual - Perception 2014 SOSE Neuroimaging of high-level visual functions gyula.kovacs@uni-jena.de 11/09/06 Functional magnetic resonance imaging (fmri) The very basics What is fmri? What is MRI? The

More information

Pre-surgical planning for brain tumor resection using functional MRI

Pre-surgical planning for brain tumor resection using functional MRI June 2011 Divya S Bolar, HMSIV Pre-surgical planning for brain tumor resection using functional MRI Divya S. Bolar,, HMS IV 1 Our patient: clinical history 85-year year-old right-handed handed woman presents

More information

Perfusion MRI. Youngkyoo Jung, PhD Associate Professor Radiology, Biomedical Engineering, and Clinical & Translational Science Institute

Perfusion MRI. Youngkyoo Jung, PhD Associate Professor Radiology, Biomedical Engineering, and Clinical & Translational Science Institute Perfusion MRI Youngkyoo Jung, PhD Associate Professor Radiology, Biomedical Engineering, and Clinical & Translational Science Institute Perfusion The delivery of blood to a capillary bed in tissue Perfusion

More information

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and education use, including for instruction at the authors institution

More information

Assessment of longer post-labeling delays to measure CBF using pseudo-continuous ASL with background suppression

Assessment of longer post-labeling delays to measure CBF using pseudo-continuous ASL with background suppression Assessment of longer post-labeling delays to measure CBF using pseudo-continuous ASL with background suppression Poster No.: C-2189 Congress: ECR 2013 Type: Authors: Keywords: DOI: Scientific Exhibit Y.

More information

Visualization strategies for major white matter tracts identified by diffusion tensor imaging for intraoperative use

Visualization strategies for major white matter tracts identified by diffusion tensor imaging for intraoperative use International Congress Series 1281 (2005) 793 797 www.ics-elsevier.com Visualization strategies for major white matter tracts identified by diffusion tensor imaging for intraoperative use Ch. Nimsky a,b,

More information

Biophysical and physiological bases of fmri signals: challenges of interpretation and methodological concerns

Biophysical and physiological bases of fmri signals: challenges of interpretation and methodological concerns Biophysical and physiological bases of fmri signals: challenges of interpretation and methodological concerns Antonio Ferretti aferretti@itab.unich.it Institute for Advanced Biomedical Technologies, University

More information

Introduction to Functional MRI

Introduction to Functional MRI Introduction to Functional MRI Douglas C. Noll Department of Biomedical Engineering Functional MRI Laboratory University of Michigan Outline Brief overview of physiology and physics of BOLD fmri Background

More information

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008 MIT OpenCourseWare http://ocw.mit.edu HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008 For information about citing these materials or our Terms of Use, visit: http://ocw.mit.edu/terms.

More information

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008 MIT OpenCourseWare http://ocw.mit.edu HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008 For information about citing these materials or our Terms of Use, visit: http://ocw.mit.edu/terms.

More information

RECENT ADVANCES IN CLINICAL MR OF ARTICULAR CARTILAGE

RECENT ADVANCES IN CLINICAL MR OF ARTICULAR CARTILAGE In Practice RECENT ADVANCES IN CLINICAL MR OF ARTICULAR CARTILAGE By Atsuya Watanabe, MD, PhD, Director, Advanced Diagnostic Imaging Center and Associate Professor, Department of Orthopedic Surgery, Teikyo

More information

Concurrent near-infrared spectroscopy (NIRS) and functional magnetic resonance imaging (fmri) of the brain

Concurrent near-infrared spectroscopy (NIRS) and functional magnetic resonance imaging (fmri) of the brain Motor cortex activation fmri Near-infrared imaging Concurrent near-infrared spectroscopy (NIRS) and functional magnetic resonance imaging (fmri) of the brain Sergio Fantini s group, Department of Biomedical

More information

APPLICATIONS OF ASL IN NEUROSCIENCE

APPLICATIONS OF ASL IN NEUROSCIENCE APPLICATIONS OF ASL IN NEUROSCIENCE Luis Hernandez-Garcia, Ph.D. Functional MRI laboratory University of Michigan 1 OVERVIEW Quick review of ASL The niche for ASL Examples of practical applications in

More information

Essentials of Clinical MR, 2 nd edition. 99. MRA Principles and Carotid MRA

Essentials of Clinical MR, 2 nd edition. 99. MRA Principles and Carotid MRA 99. MRA Principles and Carotid MRA As described in Chapter 12, time of flight (TOF) magnetic resonance angiography (MRA) is commonly utilized in the evaluation of the circle of Willis. TOF MRA allows depiction

More information

Allen W. Song, Marty G. Woldorff, Stacey Gangstead, George R. Mangun, and Gregory McCarthy

Allen W. Song, Marty G. Woldorff, Stacey Gangstead, George R. Mangun, and Gregory McCarthy NeuroImage 17, 742 750 (2002) doi:10.1006/nimg.2002.1217 Enhanced Spatial Localization of Neuronal Activation Using Simultaneous Apparent-Diffusion-Coefficient and Blood-Oxygenation Functional Magnetic

More information

Investigations in Resting State Connectivity. Overview

Investigations in Resting State Connectivity. Overview Investigations in Resting State Connectivity Scott FMRI Laboratory Overview Introduction Functional connectivity explorations Dynamic change (motor fatigue) Neurological change (Asperger s Disorder, depression)

More information

NeuroImage 43 (2008) 1 9. Contents lists available at ScienceDirect. NeuroImage. journal homepage:

NeuroImage 43 (2008) 1 9. Contents lists available at ScienceDirect. NeuroImage. journal homepage: NeuroImage 43 (2008) 1 9 Contents lists available at ScienceDirect NeuroImage journal homepage: www.elsevier.com/locate/ynimg Cortical layer-dependent dynamic blood oxygenation, cerebral blood flow and

More information

Perfusion Physics. ICMRI2018 March 29-31, 2018 Grand Hilton Hotel, Seoul, Korea. Asian Forum Ⅱ: Perfusion MRI SY24-1.

Perfusion Physics. ICMRI2018 March 29-31, 2018 Grand Hilton Hotel, Seoul, Korea. Asian Forum Ⅱ: Perfusion MRI SY24-1. SY24-1 Perfusion Physics Hiroyuki Kabasawa MR Collaborations and Development, GE Healthcare, Tokyo, Japan Perfusion is referred as the blood supply to micro capillary in tissue. Perfusion parameter such

More information

MRI qbold Based Evaluation. Renal Oxidative Metabolism. Department of Radiology and Hernando Gomez, MD Critical Care Medicine

MRI qbold Based Evaluation. Renal Oxidative Metabolism. Department of Radiology and Hernando Gomez, MD Critical Care Medicine MRI qbold Based Evaluation of Renal Oxidative Metabolism Xiang He, PhD Department of Radiology and Hernando Gomez, MD Critical Care Medicine Background High oxygen-demand and lower medullary blood flow

More information

1Pulse sequences for non CE MRA

1Pulse sequences for non CE MRA MRI: Principles and Applications, Friday, 8.30 9.20 am Pulse sequences for non CE MRA S. I. Gonçalves, PhD Radiology Department University Hospital Coimbra Autumn Semester, 2011 1 Magnetic resonance angiography

More information

Sung Hong Park. M.S. in Electrical Engineering, KAIST, South Korea, Submitted to the Graduate Faculty of

Sung Hong Park. M.S. in Electrical Engineering, KAIST, South Korea, Submitted to the Graduate Faculty of NONINVASIVE IMAGING OF BRAIN VASCULATURE WITH HIGH RESOLUTION BLOOD OXYGENATION LEVEL DEPENDENT VENOGRAPHY IN MAGNETIC RESONANCE IMAGING: APPLICATIONS TO FUNCTIONAL AND CLINICAL STUDIES by Sung Hong Park

More information

Fat Suppression in the Abdomen

Fat Suppression in the Abdomen Clinical How I do it? Fat Suppression in the Abdomen Wilhelm Horger Siemens Medical Solutions, Erlangen, Germany Introduction Due to the different chemical environment, hydrogen nuclei in - and in -tissue

More information

Cortical layer-dependent BOLD and CBV responses measured by spin-echo and gradient-echo fmri: Insights into hemodynamic regulation

Cortical layer-dependent BOLD and CBV responses measured by spin-echo and gradient-echo fmri: Insights into hemodynamic regulation www.elsevier.com/locate/ynimg NeuroImage 30 (2006) 1149 1160 Cortical layer-dependent BOLD and CBV responses measured by spin-echo and gradient-echo fmri: Insights into hemodynamic regulation Fuqiang Zhao,

More information

Sources of Functional Apparent Diffusion Coefficient Changes Investigated by Diffusion-Weighted Spin-Echo fmri

Sources of Functional Apparent Diffusion Coefficient Changes Investigated by Diffusion-Weighted Spin-Echo fmri Sources of Functional Apparent Diffusion Coefficient Changes Investigated by Diffusion-Weighted Spin-Echo fmri Tao Jin, 1 * Fuqiang Zhao, 2 and Seong-Gi Kim 1,2 Magnetic Resonance in Medicine 56:1283 1292

More information

Biophysical and physiological origins of blood oxygenation level-dependent fmri signals

Biophysical and physiological origins of blood oxygenation level-dependent fmri signals & 2012 ISCBFM All rights reserved 0271-678X/12 $32.00 Review Article Biophysical and physiological origins of blood oxygenation level-dependent fmri signals Seong-Gi Kim 1 and Seiji Ogawa 2,3 www.jcbfm.com

More information

Cover Page. The handle holds various files of this Leiden University dissertation.

Cover Page. The handle   holds various files of this Leiden University dissertation. Cover Page The handle http://hdl.handle.net/1887/35124 holds various files of this Leiden University dissertation. Author: Wokke, Beatrijs Henriette Aleid Title: Muscle MRI in Duchenne and Becker muscular

More information

Neuroimaging. BIE601 Advanced Biological Engineering Dr. Boonserm Kaewkamnerdpong Biological Engineering Program, KMUTT. Human Brain Mapping

Neuroimaging. BIE601 Advanced Biological Engineering Dr. Boonserm Kaewkamnerdpong Biological Engineering Program, KMUTT. Human Brain Mapping 11/8/2013 Neuroimaging N i i BIE601 Advanced Biological Engineering Dr. Boonserm Kaewkamnerdpong Biological Engineering Program, KMUTT 2 Human Brain Mapping H Human m n brain br in m mapping ppin can nb

More information

Magnetic Resonance Imaging. Basics of MRI in practice. Generation of MR signal. Generation of MR signal. Spin echo imaging. Generation of MR signal

Magnetic Resonance Imaging. Basics of MRI in practice. Generation of MR signal. Generation of MR signal. Spin echo imaging. Generation of MR signal Magnetic Resonance Imaging Protons aligned with B0 magnetic filed Longitudinal magnetization - T1 relaxation Transverse magnetization - T2 relaxation Signal measured in the transverse plane Basics of MRI

More information

Invited. Methodology of Brain Perfusion Imaging. Review. Emmanuel L. Barbier, PhD, 1,2 Laurent Lamalle, PhD, 1 and Michel Décorps, PhD 1 *

Invited. Methodology of Brain Perfusion Imaging. Review. Emmanuel L. Barbier, PhD, 1,2 Laurent Lamalle, PhD, 1 and Michel Décorps, PhD 1 * JOURNAL OF MAGNETIC RESONANCE IMAGING 13:496 520 (2001) Review Invited Methodology of Brain Perfusion Imaging Emmanuel L. Barbier, PhD, 1,2 Laurent Lamalle, PhD, 1 and Michel Décorps, PhD 1 * Numerous

More information

Improved spatial localization of post-stimulus BOLD undershoot relative to positive BOLD

Improved spatial localization of post-stimulus BOLD undershoot relative to positive BOLD www.elsevier.com/locate/ynimg NeuroImage 34 (2007) 1084 1092 Improved spatial localization of post-stimulus BOLD undershoot relative to positive BOLD Fuqiang Zhao, Tao Jin, Ping Wang, and Seong-Gi Kim

More information

MR Advance Techniques. Cardiac Imaging. Class IV

MR Advance Techniques. Cardiac Imaging. Class IV MR Advance Techniques Cardiac Imaging Class IV Heart The heart is a muscular organ responsible for pumping blood through the blood vessels by repeated, rhythmic contractions. Layers of the heart Endocardium

More information

Classification and Statistical Analysis of Auditory FMRI Data Using Linear Discriminative Analysis and Quadratic Discriminative Analysis

Classification and Statistical Analysis of Auditory FMRI Data Using Linear Discriminative Analysis and Quadratic Discriminative Analysis International Journal of Innovative Research in Computer Science & Technology (IJIRCST) ISSN: 2347-5552, Volume-2, Issue-6, November-2014 Classification and Statistical Analysis of Auditory FMRI Data Using

More information

A Primer on Functional Magnetic Resonance Imaging

A Primer on Functional Magnetic Resonance Imaging DOI 10.1007/s11065-007-908-8 ORIGINAL PAPER A Primer on Functional Magnetic Resonance Imaging Gregory G. Brown Joanna E. Perthen Thomas T. Liu Richard B. Buxton Received: March 007 / Accepted: 4 March

More information

High-resolution T 2 -reversed magnetic resonance imaging on a high-magnetic field system Technical note

High-resolution T 2 -reversed magnetic resonance imaging on a high-magnetic field system Technical note High-resolution T 2 -reversed magnetic resonance imaging on a high-magnetic field system Technical note Yukihiko Fujii, M.D., Ph.D., Naoki Nakayama, M.D., and Tsutomu Nakada, M.D., Ph.D. Departments of

More information

BOLD signal dependence on blood flow and metabolism. Outline

BOLD signal dependence on blood flow and metabolism. Outline BOLD signal dependence on blood flow and metabolism R. Hoge, MGH NMR Center Outline physiological events accompanying neuronal activation factors affecting BOLD signal sensitivity BOLD response dynamics

More information

Supplementary Information Methods Subjects The study was comprised of 84 chronic pain patients with either chronic back pain (CBP) or osteoarthritis

Supplementary Information Methods Subjects The study was comprised of 84 chronic pain patients with either chronic back pain (CBP) or osteoarthritis Supplementary Information Methods Subjects The study was comprised of 84 chronic pain patients with either chronic back pain (CBP) or osteoarthritis (OA). All subjects provided informed consent to procedures

More information

6/23/2009. Inversion Recovery (IR) Techniques and Applications. Variations of IR Technique. STIR, FLAIR, TI and TI Null. Applications of IR

6/23/2009. Inversion Recovery (IR) Techniques and Applications. Variations of IR Technique. STIR, FLAIR, TI and TI Null. Applications of IR The Anatomy of Basic R Pulse Sequences Inversion Recovery () Techniques and Applications Chen Lin, PhD Indiana University School of edicine & Clarian Health Partners agnetization Preparation Section Chemical

More information

Event-Related fmri and the Hemodynamic Response

Event-Related fmri and the Hemodynamic Response Human Brain Mapping 6:373 377(1998) Event-Related fmri and the Hemodynamic Response Randy L. Buckner 1,2,3 * 1 Departments of Psychology, Anatomy and Neurobiology, and Radiology, Washington University,

More information

Procedia - Social and Behavioral Sciences 159 ( 2014 ) WCPCG 2014

Procedia - Social and Behavioral Sciences 159 ( 2014 ) WCPCG 2014 Available online at www.sciencedirect.com ScienceDirect Procedia - Social and Behavioral Sciences 159 ( 2014 ) 743 748 WCPCG 2014 Differences in Visuospatial Cognition Performance and Regional Brain Activation

More information

Table 1. Summary of PET and fmri Methods. What is imaged PET fmri BOLD (T2*) Regional brain activation. Blood flow ( 15 O) Arterial spin tagging (AST)

Table 1. Summary of PET and fmri Methods. What is imaged PET fmri BOLD (T2*) Regional brain activation. Blood flow ( 15 O) Arterial spin tagging (AST) Table 1 Summary of PET and fmri Methods What is imaged PET fmri Brain structure Regional brain activation Anatomical connectivity Receptor binding and regional chemical distribution Blood flow ( 15 O)

More information

MEDICAL REVIEW Functional Magnetic Resonance Imaging: From Acquisition to Application

MEDICAL REVIEW Functional Magnetic Resonance Imaging: From Acquisition to Application Functional Magnetic Resonance Imaging: From Acquisition to Application Gail Yarmish * and Michael L. Lipton *, Departments of Radiology *, and Neuroscience Albert Einstein College of Medicine Bronx, New

More information

Supplemental Information. It is useful at the outset to more formally define reliability using concepts derived from

Supplemental Information. It is useful at the outset to more formally define reliability using concepts derived from Supplemental Information Classical Test Theory It is useful at the outset to more formally define reliability using concepts derived from classical test theory (CTT). According to classical test theory,

More information

Quantification of Cerebral Arterial Blood Volume and Cerebral Blood Flow Using MRI With Modulation of Tissue and Vessel (MOTIVE) Signals

Quantification of Cerebral Arterial Blood Volume and Cerebral Blood Flow Using MRI With Modulation of Tissue and Vessel (MOTIVE) Signals Quantification of Cerebral Arterial Blood Volume and Cerebral Blood Flow Using MRI With Modulation of Tissue and Vessel (MOTIVE) Signals Tae Kim 1,2 and Seong-Gi Kim 1,3 * Magnetic Resonance in Medicine

More information

Removal of Nuisance Signal from Sparsely Sampled 1 H-MRSI Data Using Physics-based Spectral Bases

Removal of Nuisance Signal from Sparsely Sampled 1 H-MRSI Data Using Physics-based Spectral Bases Removal of Nuisance Signal from Sparsely Sampled 1 H-MRSI Data Using Physics-based Spectral Bases Qiang Ning, Chao Ma, Fan Lam, Bryan Clifford, Zhi-Pei Liang November 11, 2015 1 Synopsis A novel nuisance

More information

Arterial versus total blood volume changes during neural activity-induced cerebral blood flow change: implication for BOLD fmri

Arterial versus total blood volume changes during neural activity-induced cerebral blood flow change: implication for BOLD fmri & 2007 ISCBFM All rights reserved 0271-678X/07 $30.00 www.jcbfm.com Arterial versus total blood volume changes during neural activity-induced cerebral blood flow change: implication for BOLD fmri Tae Kim

More information

Overview. Fundamentals of functional MRI. Task related versus resting state functional imaging for sensorimotor mapping

Overview. Fundamentals of functional MRI. Task related versus resting state functional imaging for sensorimotor mapping Functional MRI and the Sensorimotor System in MS Nancy Sicotte, MD, FAAN Professor and Vice Chair Director, Multiple Sclerosis Program Director, Neurology Residency Program Cedars-Sinai Medical Center

More information

The neurolinguistic toolbox Jonathan R. Brennan. Introduction to Neurolinguistics, LSA2017 1

The neurolinguistic toolbox Jonathan R. Brennan. Introduction to Neurolinguistics, LSA2017 1 The neurolinguistic toolbox Jonathan R. Brennan Introduction to Neurolinguistics, LSA2017 1 Psycholinguistics / Neurolinguistics Happy Hour!!! Tuesdays 7/11, 7/18, 7/25 5:30-6:30 PM @ the Boone Center

More information

Neural Correlates of Human Cognitive Function:

Neural Correlates of Human Cognitive Function: Neural Correlates of Human Cognitive Function: A Comparison of Electrophysiological and Other Neuroimaging Approaches Leun J. Otten Institute of Cognitive Neuroscience & Department of Psychology University

More information

NIH Public Access Author Manuscript Otolaryngol Head Neck Surg. Author manuscript; available in PMC 2011 August 1.

NIH Public Access Author Manuscript Otolaryngol Head Neck Surg. Author manuscript; available in PMC 2011 August 1. NIH Public Access Author Manuscript Published in final edited form as: Otolaryngol Head Neck Surg. 2010 August ; 143(2): 304 306. doi:10.1016/j.otohns.2010.03.012. Application of diffusion tensor imaging

More information

Tissue-engineered medical products Evaluation of anisotropic structure of articular cartilage using DT (Diffusion Tensor)-MR Imaging

Tissue-engineered medical products Evaluation of anisotropic structure of articular cartilage using DT (Diffusion Tensor)-MR Imaging Provläsningsexemplar / Preview TECHNICAL REPORT ISO/TR 16379 First edition 2014-03-01 Tissue-engineered medical products Evaluation of anisotropic structure of articular cartilage using DT (Diffusion Tensor)-MR

More information

(This is a sample cover image for this issue. The actual cover is not yet available at this time.)

(This is a sample cover image for this issue. The actual cover is not yet available at this time.) (This is a sample cover image for this issue. The actual cover is not yet available at this time.) This article appeared in a journal published by Elsevier. The attached copy is furnished to the author

More information

Liver Fat Quantification

Liver Fat Quantification Liver Fat Quantification Jie Deng, PhD, DABMP Department of Medical Imaging May 18 th, 2017 Disclosure Research agreement with Siemens Medical Solutions 2 Background Non-alcoholic fatty liver diseases

More information

Non Contrast MRA. Mayil Krishnam. Director, Cardiovascular and Thoracic Imaging University of California, Irvine

Non Contrast MRA. Mayil Krishnam. Director, Cardiovascular and Thoracic Imaging University of California, Irvine Non Contrast MRA Mayil Krishnam Director, Cardiovascular and Thoracic Imaging University of California, Irvine No disclosures Non contrast MRA-Why? Limitations of CTA Radiation exposure Iodinated contrast

More information

Knee Articular Cartilage in an Asymptomatic Population : Comparison of T1rho and T2 Mapping

Knee Articular Cartilage in an Asymptomatic Population : Comparison of T1rho and T2 Mapping TR_002 Technical Reports Knee Articular Cartilage in an Asymptomatic Population : Comparison of T1rho and T2 Mapping Min A Yoon 1,*, Suk-Joo Hong 1, Chang Ho Kang 2, Baek Hyun Kim 3 1 Korea University

More information

Feasibility of using Arterial Spin Labeling for Detecting Longitudinal Changes in Cerebral Blood Flow

Feasibility of using Arterial Spin Labeling for Detecting Longitudinal Changes in Cerebral Blood Flow Western University Scholarship@Western Electronic Thesis and Dissertation Repository November 2015 Feasibility of using Arterial Spin Labeling for Detecting Longitudinal Changes in Cerebral Blood Flow

More information

How Much Tesla Is Too Much?

How Much Tesla Is Too Much? How Much Tesla Is Too Much? Johnny U. V. Monu, MB, BS; MSc Professor of Radiology and Orthopedics University of Rochester School of Medicine Rochester, New York Historical Timeline Clinical Imaging 1970

More information

Functional Magnetic Resonance Imaging

Functional Magnetic Resonance Imaging Todd Parrish, Ph.D. Director of the Center for Advanced MRI Director of MR Neuroimaging Research Associate Professor Department of Radiology Northwestern University toddp@northwestern.edu Functional Magnetic

More information

PETER PAZMANY CATHOLIC UNIVERSITY Consortium members SEMMELWEIS UNIVERSITY, DIALOG CAMPUS PUBLISHER

PETER PAZMANY CATHOLIC UNIVERSITY Consortium members SEMMELWEIS UNIVERSITY, DIALOG CAMPUS PUBLISHER PETER PAZMANY CATHOLIC UNIVERSITY SEMMELWEIS UNIVERSITY Development of Complex Curricula for Molecular Bionics and Infobionics Programs within a consortial* framework** Consortium leader PETER PAZMANY

More information

Functional MRI at High Fields: Practice and Utility

Functional MRI at High Fields: Practice and Utility FUNCTIONAL MRI AT HIGH FIELDS: PRACTICE AND UTILITY 1 Functional MRI at High Fields: Practice and Utility Kamil Ugurbil, Wei Chen, Xiaoping Hu, Seong-Gi Kim, Xiao-Hung Zhu Center for Magnetic Resonance

More information

Twelve right-handed subjects between the ages of 22 and 30 were recruited from the

Twelve right-handed subjects between the ages of 22 and 30 were recruited from the Supplementary Methods Materials & Methods Subjects Twelve right-handed subjects between the ages of 22 and 30 were recruited from the Dartmouth community. All subjects were native speakers of English,

More information

Neurovascular Coupling

Neurovascular Coupling Cerebral Blood Flow and Brain Activation UCLA NITP July 2012 Neurovascular Coupling Richard B. Buxton University of California, San Diego rbuxton@ucsd.edu... The subject to be observed lay on a delicately

More information

An introduction to functional MRI

An introduction to functional MRI An introduction to functional MRI Bianca de Haan and Chris Rorden Introduction...1 1 The basics of MRI...1 1.1 The brain in a magnetic field...1 1.2 Application of the radiofrequency pulse...3 1.3 Relaxation...4

More information