v Feature Stamping SMS 12.0 Tutorial Prerequisites Requirements TABS model Map Module Mesh Module Scatter Module Time minutes

Similar documents
Feature Stamping SURFACE WATER MODELING SYSTEM. 1 Introduction. 2 Opening a Background Image

v Feature Stamping SMS 13.0 Tutorial Prerequisites Requirements Map Module Mesh Module Scatter Module Time minutes

IBRIDGE 1.0 USER MANUAL

CNV PCA Search Tutorial

The application can be accessed from the pull down menu by selecting ODOT > Drafting Apps > Signs, or by the following key-in command:

Voxar 3D CardiaMetrix. Reference Guide

Bruker D8 Discover User Manual (Version: July 2017)

BlueBayCT - Warfarin User Guide

Contour Diabetes app User Guide

Add_A_Class_with_Class_Number_Revised Thursday, March 18, 2010

Table of Contents. Contour Diabetes App User Guide

What s New in itero Scanner 4.0

Using SPSS for Correlation

MyDispense OTC exercise Guide

Charts Worksheet using Excel Obesity Can a New Drug Help?

Kappa Apex3 instruction manual. Procedure. Version 1.0 CuKα / MoKα Duo Edition

Tutorial: RNA-Seq Analysis Part II: Non-Specific Matches and Expression Measures

PENNDOT e-notification

Estimating national adult prevalence of HIV-1 in Generalized Epidemics

Gear Tooth Root Fillet Optimization Program User manual

Sleep Apnea Therapy Software Clinician Manual

Lesson 2 EMG 2 Electromyography: Mechanical Work

ATLANTIS WebOrder. ATLANTIS ISUS User guide

Two-Dimensional Computer Modeling of Pomme de Terre River at Highways 12 and 22 in Minnesota

Commonwealth of Pennsylvania PA Test Method No. 423 Department of Transportation October Pages LABORATORY TESTING SECTION. Method of Test for

Biopac Student Lab Lesson 6 ELECTROCARDIOGRAPHY (ECG) II Analysis Procedure. Rev

Blood Glucose Monitoring System. Copyright 2016 Ascensia Diabetes Care Holdings AG diabetes.ascensia.com

QuantiPhi for RL78 and MICON Racing RL78

Term Definition Example Amino Acids

Optimum Body and Leg Extension Selection in PLS CADD

Exercise Pro Getting Started Guide

TMWSuite. DAT Interactive interface

DENTRIX ENTERPRISE 8.0.5

Release Notes DWOS Lava Edition

Sleep Apnea Therapy Software User Manual

User Guide for Classification of Diabetes: A search tool for identifying miscoded, misclassified or misdiagnosed patients

Entering HIV Testing Data into EvaluationWeb

Publishing WFS Services Tutorial

Using the CFS Infrastructure

User Manual. RaySafe i2 dose viewer

UNDERWATER BRIDGE INSPECTION REPORT STRUCTURE NO CRANE LAKE ROAD OVER HAWKINSON CREEK ST. LOUIS COUNTY

AudioConsole. User Guide. Doc. No EN/01 Part No EN

SUMMARY OF NOVEMBER 2018 REVISIONS - VERSION

To learn how to use the molar extinction coefficient in a real experiment, consider the following example.

CS User and Installation Guide

01/2018 English. Instruction Manual. Creating Implant Libraries for DentalCAD. exocad.com

ShadeVision v Color Map

Simple Caption Editor User Guide. May, 2017

Nodule Detection process: 1. Click on the patient study to be loaded 2. Click the drop down arrow next to the analysis button and select LNA

Meta-analysis using RevMan. Yemisi Takwoingi October 2015

Add_A_Class_with_Class_Search_Revised Thursday, March 18, 2010

NOE/NOTR Form and Electronic File Creation

Adding an Event to the Campus Calendar

1. To review research methods and the principles of experimental design that are typically used in an experiment.

Excel Solver. Table of Contents. Introduction to Excel Solver slides 3-4. Example 1: Diet Problem, Set-Up slides 5-11

VMA Demo Unit. Introduction. This document provides information on how to set up and operate the VMA Demo Unit. Figure 1: VMA Demo Unit

Module 3: Pathway and Drug Development

Appendix B. Nodulus Observer XT Instructional Guide. 1. Setting up your project p. 2. a. Observation p. 2. b. Subjects, behaviors and coding p.

5 Working With Measurements

ABSCOUR 9 USERS MANUAL

Warfarin Help Documentation

MedsCheck Reviews. Ontario

Here are the various choices. All of them are found in the Analyze menu in SPSS, under the sub-menu for Descriptive Statistics :

Available for CEREC SW, inlab CAD SW, 3Shape, Dental Wings, DWOS Lava Edition, exocad, Open design software. Atlantis. Atlantis Core File.

Center of Dilation. Vertical Distance: 6. Horizontal Distance: 4

Matrix sentence test (Italian)

Tech Talk: Using the Lafayette ESS Report Generator

EDUCATIONAL TECHNOLOGY MAKING AUDIO AND VIDEO ACCESSIBLE

RELEASED. Clearing your active insulin

15.053x. OpenSolver (

Biopac Student Lab Lesson 3 ELECTROENCEPHALOGRAPHY (EEG) I Analysis Procedure. Rev

To open a CMA file > Download and Save file Start CMA Open file from within CMA

N4i Installation Manual. (picture of N4i screen)

Lesson 1 ELECTROMYOGRAPHY I Standard and Integrated EMG

Version Date: 2015-OCT-29. Effective Date: 2015-NOV-19

RESULTS REPORTING MANUAL. Hospital Births Newborn Screening Program June 2016

Exercise 2: Effects of Cold Temperature Aim: To record changes in heart rate after the heart is bathed in cold Ringer s solution.

Managing and Taking Notes

SANAKO Lab 100 STS USER GUIDE

Lesson 4 ECG 2 Electrocardiography

ECG-PS ECG SIGNAL MEASUREMENT MODULE. Operation Manual. March 2005

Making a Room Reservation with Service Requests in Virtual EMS

Managing and Taking Notes

ReSound Forte and ReSound Smart 3D App For Android Users Frequently Asked Questions

Technical Bulletin. Technical Information for Quidel Molecular Influenza A+B Assay on the Bio-Rad CFX96 Touch

LiteLink mini USB. Diatransfer 2

MEAT CONTENT CALCULATION

CADstar Academy. CS Ultra Advanced Module

Lesson 1: Types of ECG s

THE MINIMED 670G SYSTEM SCHOOL NURSE GUIDE

7. Bivariate Graphing

The North Carolina Health Data Explorer

Mobile App User Guide

NUTRITIONAL ANALYSIS PROJECT

MA 151: Using Minitab to Visualize and Explore Data The Low Fat vs. Low Carb Debate

ESD 113 Sound to Harbor Head Start/ECEAP Procedure 620 Page 1 of 6 HEALTH SCREENINGS PROCEDURE. Health Section

Medtech32 Diabetes Get Checked II Advanced Form Release Notes

CrystalPM - AOA MORE Integration and MIPS (CQM) Tutorial

Transcription:

v. 12.0 SMS 12.0 Tutorial Objectives In this lesson will teach how to use conceptual modeling techniques to create numerical models that incorporate flow control structures into existing bathymetry. The flow control structures that will be created are abutments for a proposed bridge over Double Pipe Creek near Detour, Maryland. To do this the user will be using feature stamping. Prerequisites None Requirements TABS model Map Module Mesh Module Scatter Module Time 30-45 minutes Page 1 of 11 Aquaveo 2014

1 Opening a Background Image... 2 2 Specifying the Coordinate System... 3 3 Importing Bathymetric Data... 3 4 Creating the Model Domain... 4 5 Create a Mesh Without the Abutments... 5 6 Creating the Abutments... 6 6.1 Setting Up a Stamping Coverage... 6 6.2 Positioning the Abutments... 6 6.3 Specifying the Geometry of the Abutments... 7 6.4 Stamping the Abutments... 8 6.5 Incorporating the Abutments into a Numerical Model... 9 7 Conclusion... 11 1 Opening a Background Image To provide a base map and to help place the centerlines for the abutments of the proposed bridge, open an aerial photograph of Double Pipe Creek near Detour, Maryland. To open the image: 1. Select File Open... 2. Select DoublePipeCreekPhoto.jpg in the Data Files Folder for this tutorial and click the Open button. 3. Depending on the preference settings, SMS may ask if image pyramids are desired. It is advised that the toggle to not ask this question again be selected and click Yes. SMS displays the aerial photograph (Figure 1). Figure 1 Aerial photograph of Double Pipe Creek near Detour, Maryland Page 2 of 11 Aquaveo 2014

2 Specifying the Coordinate System The image has now been read into SMS, but SMS has not been told what coordinate system the data is referenced to. The coordinate system is dependent on the data source. To specify the coordinate system: 1. Select Display Projection... to bring up the Display Projection dialog. 2. In the dialog, make sure the Horizontal system is set as No projection and the Horizontal and Vertical Units are set to U.S. Survey Feet. Click OK. 3 Importing Bathymetric Data This tutorial uses bathymetry from a survey of the area around Double Pipe Creek near Detour, Maryland before construction of the elevated road and bridge. To bring the survey data into SMS: 1. Select File Open... to bring up the Open dialog. 2. Select detour.xyz and click the Open button. 3. The File Import Wizard dialog will appear. Make certain the Space delimiter is checked. 4. Change Start import at row to 2 and uncheck Heading row. 5. Click Next to proceed to step 2 of the File Import Wizard. 6. Click Finish to close the File Import Wizard and import the survey data. 7. Next go into the Display Display Options menu command to bring up the Display Options dialog. 8. Select the Scatter section and switch off the points and select contours. 9. Click on the Contours tab and switch the Contour method to Color Fill and change the Transparency to 50% and click OK. This survey file contains elevation data for Double Pipe Creek and its floodplain which includes the town of Detour, Maryland. The survey data has already been adjusted to the same local coordinate system as the image. Transparent contours of the survey points displayed over the background image are shown in Figure 2. Page 3 of 11 Aquaveo 2014

Figure 2 Bathymetry for Double Pipe Creek and its floodplain 4 Creating the Model Domain Before creating a numerical model, a conceptual model will be created to define the extents of the model domain. By using a conceptual model, users can take advantage of automatic meshing algorithms. The two sides of the model domain running along the length of Double Pipe Creek will be formed by extracting the 330 foot contour from the survey data. The ends of these two boundaries will then be connected to create the upstream and downstream boundaries of the model domain. To define the model domain: 1. Right-click on the Map Data item in the Project Explorer and select the New Coverage menu command. The New Coverage dialog will appear. 2. Name the coverage Double Pipe Bridge and select TABS as the coverage type. Users will need to scroll down to reach the TABS coverage option. Click OK. 3. Right-click on the detour scatter set in the Project Explorer and select the Convert Scatter Contours Map menu item. 4. In the Create Contour Arcs dialog, enter an Elevation of 330 feet and a Spacing along contour of 100 feet. 5. Click OK to close the Create Contour Arcs dialog and generate arcs along the 330 foot contour. The resulting arcs run along the length of Double Pipe Creek. 6. A single looped arc is created on the extreme east side of the scatter set. Delete this arc. To do this: 1. Switch to the Map module if it isn t selected already. Page 4 of 11 Aquaveo 2014

2. Click on the Select Feature Arc tool, click on the single looped arc and press Delete on the keyboard. It may help to zoom in before clicking the arc. 3. Say Yes to the dialog. 7. With the Create Feature Arc tool create the upstream and downstream boundaries of the model domain as shown in Figure 3. It may be necessary to zoom in and turn off the scatter set. Delete any dangling arcs that result when creating these two boundaries. Note the arcs are not to be placed on the ends of the existing arcs. Figure 3 Model domain of Double Pipe Creek The model domain extents are now defined in the Double Pipe Bridge coverage. It is important to note than when creating a finite element mesh from a conceptual model, the bathymetry is interpolated from the scatter set. Therefore, the conceptual model should be within the bounds of the scatter set to avoid difficulties that arise when extrapolating data. 5 Create a Mesh Without the Abutments Next is to first create a finite element mesh that does not include the abutments. This represents the existing conditions model and the abutments would represent a proposed condition. 1. A conceptual model using the merged scatter set has been prepared. To open it, open the file NoAbutments.map by selecting File Open. All of the polygons forming this conceptual model reference the detour scatter set. 2. To create the numerical model select Feature Objects Map 2D Mesh. 3. Click OK in the 2D Mesh Options dialog. Page 5 of 11 Aquaveo 2014

4. The user may be asked to name the mesh in a new Mesh Name dialog. Click OK. 6 Creating the Abutments As mentioned above, the abutments of the proposed roadway will be created using feature stamping. This tutorial presents stamping the abutments for the proposed bridge over Double Pipe Creek in five steps, which will be broken down and explained in section 6.1-6.5: 1. Set up a Stamping coverage. 2. Position the abutments. 3. Specify the geometry of the abutments. 4. Stamp the abutments into the existing bathymetry. 5. Incorporate the stamped features to the conceptual model. 6.1 Setting Up a Stamping Coverage SMS includes a coverage type called a Stamping coverage, for positioning and defining the geometry of features to be forced into existing bathymetry using feature stamping. To setup the Stamping coverage for this tutorial: 1. Right-click on Map Data in the Project Explorer and create a New Coverage. 2. In the New Coverage dialog, name the coverage Feature Stamp, and then set its Type to Stamping and activate it. 3. In the Stamping Coverage Attributes dialog, toggle on Use cutoff. Select the elevation (Z) item in the tree control and leave the Bathymetry Type as Elevation. This sets the elevation (Z) dataset of the detour scatter set as the bathymetry the stamped features will be forced into. Furthermore, by leaving the Bathymetry Type as Elevation, it tells SMS that the selected dataset contains elevation values rather than depth values. 4. Click OK to close the Stamping Coverage Attributes dialog. 6.2 Positioning the Abutments Next is to position the abutments by creating feature arcs along their centerlines. The accuracy in how the abutments intersect the existing bathymetry depends on how many vertices are distributed along the centerline arcs. For this tutorial, it is necessary to distribute the vertices so they are closer together where the slope of the bathymetry changes rapidly near the banks of the creek and further apart where the slope is nearly flat in the floodplain. To create the centerline arcs for the abutments: 1. Using the Create Feature Arc tool create arcs representing the centerlines of the two abutments as shown in Figure 4. Use the roadway in the aerial Page 6 of 11 Aquaveo 2014

photograph to help position the centerline arcs and line them up with each other. Create the arcs starting outside the model domain in the floodplain and proceeding toward the Double Pipe Creek. End the arcs at the edge of the creek. The length of the bridge will be roughly the distance between the two nodes. Some users may have to adjust the display options or zoom in to better see the model domain on the Double Pipe Bridge coverage. 2. With the Select Feature Arc tool, select the centerline arc for the west abutment and select Feature Objects Redistribute Vertices. This brings up the Redistribute Vertices dialog. 3. In the Redistribute Vertices dialog set Specify to Number of Segments, the Number of to 20 and the Bias to 0.1. The Bias positions the vertices so that the distance between the last two vertices is 0.1 times the distance between the first two vertices. Click OK to close the Redistribute Vertices dialog. If the arcs don t distribute in the same manner as in Figure 4 then try to use a Bias of 10. 4. Redistribute the vertices along the centerline for the east abutment in a similar manner using 30 segments. Set a bias of 0.1. Figure 4 Abutment centerlines for the proposed bridge over Double Pipe Creek 6.3 Specifying the Geometry of the Abutments Now that the abutments have been positioned with centerline arcs the user can specify their geometry. To specify the geometry of the abutments: 1. With the Select Feature Arc tool double-click on the west abutment. This brings up the Stamping Arc Attributes dialog. 2. In the Stamping Arcs Attributes dialog specify the Feature Name as West Abutment. Leave the Stamping Type as Fill Feature since this abutment will be increasing the elevation of the existing bathymetry. 3. Click the Constant Elevation button in the Centerline (CL) Profile area to bring up the Constant Elevation dialog. 4. Enter a constant elevation of 332 feet and click OK to close the dialog. This sets the elevation at each of the points along the centerline arc to 332 feet. The Page 7 of 11 Aquaveo 2014

elevations for the points along the centerline can be set one at a time in the Centerline (CL) Profile Spreadsheet or all at once using the macros found below this spreadsheet. Note that the first point along the centerline is marked with an arrow. This arrow identifies the current point. The Cross sections (CS) area of the attributes dialog displays the cross section for the current point for viewing and editing. When the current point is changed by clicking on it in the Centerline (CL) Profile Spreadsheet, the Cross sections (CS) area updates to display the cross section of the new current point. Now specify the cross sections at each point along the centerline. 5. In the Cross sections (CS) area click the Specify Top Width and Single Side Slopes macro button to bring up the Top Width and Side Slopes dialog. 6. Enter a Top Width of 25 feet and Left and Right Slopes of -1. Click OK to close the dialog. A simple cross section has now been specified. 7. To ensure these cross sections intersect the bathymetry when being stamped, specify a Maximum Distance from CL of 35 feet for both the left and right sides of the cross section. 8. Copy this cross section to the remaining centerline points by clicking the Current CS All CS macro button. Click Yes when prompted to adjust the cross sections based on the centerline elevation. 9. To specify a slope on the end of the abutment click the Last End Cap button to bring up the Last End Cap dialog. 10. Leave the Type of end cap as Sloped Abutment and the Angle as 0.0. In the last row of the Slope Spreadsheet enter a Distance from CS of 1 foot and an Elevation of 331 feet. To ensure the sloped abutment intersects the bathymetry, specify a Maximum Distance from CS of 25 feet. 11. Click OK twice to exit the Last End Cap and Stamping Arc Attributes dialogs. 12. Repeat steps 1 through 7 for the east abutment except set the Feature Name to East Abutment. The geometry for both the abutments has now been specified. For this tutorial, the user is creating fairly simple features to force into the existing bathymetry. The feature stamping interface inside SMS has been designed to create simple features quick but at the same time allow for the creation of more complex features. The model is now ready to stamping the abutments and adding them to the conceptual model. 6.4 Stamping the Abutments To maintain the integrity of the conceptual model and the existing bathymetry, feature stamping creates a new coverage and a new scatter set for each stamped feature. If the conceptual model or the existing bathymetry becomes corrupted, it makes it difficult to test several scenarios for the placement and geometric design of features being stamped. To stamp the abutments into the existing bathymetry: Page 8 of 11 Aquaveo 2014

1. Select Feature Objects Stamp Features... to bring up the Stamp Features dialog. 2. In the Stamp Features dialog make sure the Coverage Type is set to TABS and click Stamp. Notice a coverage and scatter set are added to the Project Explorer for the west abutment and east abutment. 6.5 Incorporating the Abutments into a Numerical Model There are several ways to incorporate a stamped feature into a numerical model. Two methods will be illustrated in this tutorial. The first method will use the existing mesh elements and apply the stamped elevations to the nodes of the mesh. The second method will create a new mesh that will use the stamped elevations. The new mesh will have a different configuration of elements than the original mesh. Both methods require a new scatter set that includes the stamped elevations. The second method also requires a new conceptual model. In general, the second method is the preferred approach so the user can setup the elements to match the updated bathymetry. Creating Merged Scatter Set In order to use the new scatter sets in the numeric model, users will want to combine them with the original data. To create the merged scatter set: 1. Click on the Scatter Data item in the Project Explorer to activate the Scatter Module. 2. Select Scatter Merge Sets to bring up the Merge Scatter Sets dialog. 3. Under Overlapping region options, Select Merge all scatter points. 4. In the Select scatter sets to merge section, click the Select All button to specify that all available scatter sets are to be merged. 5. At this point the user would normally click OK to close the Merge Scatter Sets dialog and create the merged scatter set. However, SMS triangulates the new set of merged points. This TIN does not always honor the stamped feature boundaries, and therefore may need to be edited (swapping triangle edges) to accurately represent the combined surface. Click OK to merge the sets. Page 9 of 11 Aquaveo 2014

Figure 5 Merged scatter set. 6. The Merge Report dialog will appear showing a summary of what was merged. Click Close to exit the dialog. To integrate the abutments into a numerical model using this method: 1. Click on the Merged item in the Project Explorer under Scatter Data to activate the Scatter Module. 2. In the menu, select Scatter Interpolate to Mesh to bring up the Interpolation dialog. 3. Under Scatter Set to Interpolate From, make sure elevation in the Merge scatter set is selected. 4. Under Other Options, Make sure that Map Z is toggled on. Click OK. In the case where the difference in elevations are not noticeable, the z magnification might have to be modified. To change the z magnification: 1. Go into the Display Options dialog. This is done by selecting Display Display Options menu command. 2. Select the General section. Make sure that Auto z-mag is turned off, then change the z magnification to 5. 3. Click OK to exit the Display Options dialog. A mesh incorporating the east and west abutments has now been created. Figure 6 shows a rotated view of the resulting mesh zoomed up to the abutments. Breaklines are automatically created when using feature stamping. Breaklines forces the contours to follow abutment when triangulation is done. Figure 7 shows the breaklines that are created during feature stamping. Page 10 of 11 Aquaveo 2014

Figure 6 Mesh incorporating the east and west abutments. Figure 7 Merged scatter set with Mesh off and breaklines showing. 7 Conclusion This tutorial demonstrates the creation of an embankment using the feature stamping utility. The same tools can be used to create channels, pits, or mounds. A user may want to experiment with some of these other options. Page 11 of 11 Aquaveo 2014