Diagnostic Audiometer

Similar documents
AC40 Technical Specificatons Page 1. Technical Specifications AC40. Clinical Audiometer

AC40 Technical Specificatons. Technical Specifications AC40. Clinical Audiometer D F 2017/11

AD226 Diagnostic Audiometer

The true hybrid Stand alone & PC-based audiometry in one box

The true clinical hybrid audiometer Stand alone & PC-based audiometry in one box. Interacoustics. Clinical Audiometer AC40.

The true hybrid Stand alone & PC-based audiometry in one box

The true clinical hybrid audiometer. Interacoustics. Clinical Audiometer AC40. Stand alone & PC-based audiometry in one box.

The true hybrid Stand alone & PC-based audiometry in one box

Equinox 2.0. PC-based audiometer. Time saving solutions. Interacoustics. leading diagnostic solutions

TWO CHANNEL CLINICAL AUDIOMETER AUDIOSTAR PRO

AC40. Clinical Audiometer. Save time Focus on results. Interacoustics. l e a d i n g d i a g n o s t i c s o l u t i o n s

Oscilla - excellence since 1960

UNITY 2. a state-of-the-art audiological integrated diagnostic and fitting system

GSI AUDIOSTAR PRO CLINICAL TWO-CHANNEL AUDIOMETER

AUDIOLAB Two channel clinical audiometer. Tonal Audiometry Vocal Audiometry MASKING SISI ABLB Decay Test BEKESY

AA222 / AA220. Audio Traveller. Save time on routine. Focus on results. Interacoustics. leading diagnostic solutions

AA-M1C1. Audiometer. Space saving is achieved with a width of about 350 mm. Audiogram can be printed by built-in printer

AUDIOMETERS AUDIXI 10

What s New in Primus

Diagnostic Impedance & Audiometry in one solution

General about Calibration and Service on Audiometers and Impedance Instruments

AT235 Middle Ear Analyzer. Diagnostic & clinical tympanometry with basic audiometry

AC40. The true clinical. hybrid

OIML R 122 Annex C RECOMMENDATION. Edition 1999 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

FONIX FA-12 Hearing Evaluator Digital Audiometer

AMBCO AUDIOMETER

Audiology Equipment p r o d u c t s c AtA l o g u E

AMBCO 1000+P AUDIOMETER

Operating Instructions MA 52

Additional Information. PC-based Audiometer Equinox 2

Operating Instructions MA 25

INTRODUCTION TO PURE (AUDIOMETER & TESTING ENVIRONMENT) TONE AUDIOMETERY. By Mrs. Wedad Alhudaib with many thanks to Mrs.

Affinity 2.0 / Equinox 2.0 Hearing Aid Analyzer

AD629 The true hybrid

The professional fitting solution

MA 25 Operating Manual

Operation Manual. Screening Audiometer AS608/AS608e

Reliable, flexible & precise

Equinox 2.0 PC-based audiometer. Not just an audiometer - A full counseling and reporting solution

MA 40 Operating Instructions

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard

TRAINING MANUAL. AVANT The Perfect Screening Audiometer AIR+

Contents. QuickSIN.. 15 Hearing Loss Simulator Master Hearing Aid Printing Limited Warranty.. 20 #0086.

Operation Manual MA 41

Neuro-Audio Version 2010

AT235/AT235h Middle Ear Analyzers. Diagnostic & clinical tympanometry with basic audiometry.

Operating Instructions MA 41

MADSEN Itera II. User Guide. Doc. No EN/04 Part No EN

Additional Information Callisto Portable Audiometry REM & HIT

This Page Left Intentionally Blank

myaudiometer. It s familiar, and it s so much

Good Things Come In Small Packages. Diagnostic & Hearing Instrument Fitting Technologies CATALOG

MADSEN Xeta. Reference Manual. Doc. No EN/16 Part No EN

ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE VEMP ECochG MLR P300

This Page Intentionally Left Blank

SOFTWARE INSTRUCTION MANUAL

FONIX FP35. Ease and Accuracy with the FP35 Touch Hearing Aid Analyzer! Visible Speech

TRAINING MANUAL. MedRx TINNOMETER. Revolutionary Tinnitus Assessment.

Quick Guide Binaural REM

Affinity 2.0 integrated fitting solution. Audiometry, REM, HIT, and Visible Speech Mapping

User Manual. - Pro Edition -

GSI 61 CLINICAL TWO-CHANNEL AUDIOMETER

Organisation Internationale de Métrologie Légale

TRAINING MANUAL. AVANT Air, Bone, Speech and Masking Audiometry AUDIOMETERS.

TRAINING MANUAL AVANT ARC. Audiometry & Binaural REM/LSM in One System.

COPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN ISO :1998

Precision Audiometric Instruments

The integrated fitting solution

User Manual. - Pro Edition -

Precision Audiometric Instruments

EPIC-PLUS System for auditory evoked potentials and neuro-otology. PEA - VEMPs ASSR - E-ABR FACIAL NERVE

General Catalogue. Product Line for Hearing Screening & Diagnostics

AURICAL Aud. User Guide. Doc. No EN/07 Part No EN

GRASON-STADLER HEARING ASSESSMENT SYSTEMS

Supplementary Online Content

MA 39 Operating Instructions

General Catalogue. Product Line for Hearing Screening & Diagnostics

Instructions for Use - US Diagnostic Suite 2.4.0

Amplivox Ltd Model 240 Diagnostic Audiometer Operating Manual

A full product range for your every need. World leading diagnostic solutions

Matrix sentence test (Italian)

General Catalogue. Hearing Screening & Diagnostics

BioMed Jena GmbH -Biomedical Technology- PRODUCT CATALOGUE AUDIOLOGY

CA850 Series 5 Audiometer Operating Manual 3 January, CA850 Series 5. Automatic Audiometer Operating Manual

Contents #

Price list Tools for Research & Development

Amplivox Ltd Model 116 Screening Audiometer Operating Manual

Operation Manual MA 27 / MA 27e

Two Modified IEC Ear Simulators for Extended Dynamic Range

The registration testing for audiometric device in CFDA

BioMed Jena GmbH -Biomedical Technology- PRODUCT CATALOGUE AUDIOLOGY

ECHOLAB. Screening and Clinical Modality. User Programmable Protocols. Otoacoustic Emissions System TEOAE - DPOAE - ABR - AABR

General Catalogue. Hearing Screening & Diagnostics

보청기의전기음향적성능분석. Kyoung Won Lee, Ph.D Hallym University of Graduate Studies

Software Training Manual

ER75 Electro-Acoustic Ear Simulator. Operating Manual

Transcription:

AD629 Technical Specificatons Page 0 Technical Specifications AD629 Diagnostic Audiometer Item No.8107429 3/2015

AD629 Technical Specificatons Page 1 License Overview International configuration AD629 Basic license Etended license Licenses Audiometry Basic Audiometry Békésy SISI Langenbeck Stenger Modified Hughson-Westlake ABLB Speech testing with CD/Mic Build-in wave files Binaural Speech Hearing Loss Simulator (HLS) MHA QuickSIN optional optional TEN test optional optional High Frequency (HF) optional optional Freefield Lineout Hyrbid mode - PC controlled mode optional optional Sync mode - Audiogram transfer optional optional Fuctions available only in Diagnostics suite Weber MaskingHelper

Chinese Czech English Finnish French German Greek Italian Japanese Korean Norwegian Polish Portuguese Russian Spanish Turkish AD629 Technical Specificatons Page 2 Languages supported in IMP and AUD IMP MT10 X X X Eisting AT235 X X New AT235 X X X X X X X X X X X X X X X X Eisting AA222 X X New AA222 X X X X X X X X X X X X X X X X Titan X X X X X X X X X X X AUD AS608 X X X X AD226 X X X X X X X X X X AD629 / AD229 X * X * X X * X X X * X X* X * X * X X * X * X X AC40 X * X * X X * X X X * X X* X * X * X X * X * X X Suites Titan suite X X X X X X X X X X X X DS X X X X X X X X X X X X X X

AD629 Technical Specificatons Page 3 Included and Optional Parts Included parts Optional parts DD45 Audiometric headset B71 Bone conductor APS3 Patient response button Goose neck microphone Power cable Operation manual CD Multilingual instructions for use Diagnostic Suite software OtoAccess database 21925 Amplivo audiocups, noise reducing headset Carrying case (Standard or Trolly Style) EARTone3A/5A Audiometric insert phones IP30 Audiometric insert phones HDA300 Audiometric headset with double mono 6.3mm jack TDH39 Audiometric headset CIR33 Insert earphone set for masking or monitoring Talk back microphone Sound field speakers SP90 (with eternal power amp) AP12 Power Amplifier 212 Watt AP70 Power Amplifier 270 Watt

AD629 Technical Specificatons Page 4 General Technical Specifications AD629 Technical Specification Safety Standards IEC 60601-1, ES60601-1, CAN/CSA-C22.2 No.60601-1 Class I, Applied parts type B, Continuous operation EMC Standard IEC 60601-1-2:2001 + A1:2004 Audiometer Standards Tone Audiometer: IEC 60645-1, ANSI S3.6-2010, Type 2, HF IEC 60645-4. Speech Audiometer: IEC 60645-2/ANSI S3.6 type B or B-E. Auto threshold tests: ISO 8253-1 Calibration Calibration information and instructions is located in the AD629 Service manual Air Conduction DD45: PTB/DTU report 2009 TDH39: ISO 389-1 1998, ANSI S3.6-2010 HDA300: PTB report PTB 1.61 4064893/13 HDA280 PTB report 2004 E.A.R Tone 3A/5A: ISO 389-2 1994, ANSI S3.6-2010 IP 30: ISO 389-2 1994, ANSI S3.6-2010 DES-2361 CIR 33 ISO 389-2 Bone Conduction B71: ISO 389-3 1994, ANSI S3.6-2010 Placement: Mastoid Free Field High Frequency Effective masking ISO 389-7 2005, ANSI S3.6-2010 ISO 389-5 2004, ANSI S3.6-2010 ISO 389-4 1994, ANSI S3.6-2010 Transducers DD45 Headband Static Force 4.5N 0.5N TDH39 Headband Static Force 4.5N 0.5N HDA300 Headband Static Force 4.5N 0.5N HDA280 Headband Static Force 5N 0.5N B71 Bone Headband Static Force 5.4N 0.5N E.A.R Tone 3A/5A: IP30 CIR 33 Patient Response switch Patient communication Monitor Special tests/test battery One hand held push button. Talk Forward (TF) and Talk Back (TB). Output through built-in speaker or through eternal earphone or speaker. SISI. ABLB. Stenger. Stenger Speech. Langenbeck (tone in noise). Békésy Test. 2 channel speech, 2 channels Master Hearing Aid, Auto threshold. Auto threshold tests: Available time for patient to respond: Same as tone presentation Increment of hearing level: 5dB. Auto threshold test (Békésy): Mode of operation: Békésy Rate of level change: 2.5 db/s ±20% Smallest increment of level: 0.5 db Stimuli Tone Warble Tone 125-20000Hz separated in two ranges 125-8000Hz and 8000-20000Hz. Resolution 1/2-1/24 octave. 1-10 Hz sine +/- 5% modulation

AD629 Technical Specificatons Page 5 Wave file Masking 44100Hz sampling, 16 bits, 2 channels Automatic selection of narrow band noise (or white noise) for tone presentation and speech noise for speech presentation. Narrow band noise: IEC 60645-1:2001, 5/12 Octave filter with the same centre frequency resolution as pure Tone. White noise: 80-20000Hz measured with constant bandwidth Speech Noise. IEC 60645-2:1993 125-6000Hz falling 12dB/octave above 1KHz +/-5dB Presentation Intensity Manual or Reverse. Single or multiple pulses. Check the accompanying Appendi Available Intensity Steps is 1, 2 or 5dB Etended range function: If not activated, the Air Conduction output will be limited to 20 db below maimum output. Frequency range Speech 125Hz to 8kHz (Optional High Frequency: 8 khz to 20 khz) 125Hz, 250Hz, 750Hz, 1500Hz and 8kHz may freely be deselected Frequency Response: (Typical) TDH39 (IEC 60318-3 Coupler) Frequecy (Hz) 125-250 250-4000 4000-6300 Linear (db) FFequv (db Et sign 1 Int. Sign 2 Et sign 1 Int. Sign 2 +2/-1 +0/-8 +0/-8 DD45 (IEC 60318-3 Coupler) 125-250 250-4000 4000-6300 +0/- +0/-7 +2/-3 E.A.R Tone 3A (IEC 60318-5 Coupler) IP 30 (IEC 60318-5 Coupler) B71 Bone Conductor (IEC 60318-6 Coupler) 250-4000 +2/-3 +4/-1 (Non linear) 250-4000 +2/-3 +4/-1 (Non linear) 250-4000 +12/-12 +12/-12 (Non linear) 2% THD at 1000 Hz ma output +9 db (increasing at lower frequency) Level range: -10 to 50 db HL 1. Et. sign: CD input 2. Int. sign: Wave files Eternal signal Speech replaying equipment connected to the CD input must have a signal-to-noise ratio of 45 db or higher. The speech material used must include a calibration signal suitable for adjusting the input to 0 dbvu. Free Field Power amplifier and loudspeakers With an input of 7 Vrms - Amplifier and loudspeakers must be able to create a Sound Pressure Level of 100 db in a distance of 1 meter - and meet the following requirements: Frequency Response 125-250 Hz +0/-10 db 250-4000 Hz ±3 db 4000-6300 Hz ±5 db Total Harmonic Distortion 80 db SPL < 3% 100 db SPL < 10% Internal storage 250 patients and unlimited sessions/measurements/audiograms

AD629 Technical Specificatons Page 6 Signal Indicator(VU) Time weighting: 300mS Dynamic range: 23dB Rectifier characteristics: RMS Selectable inputs are provide with an attenuator by which the level can be adjusted to the indicator reference position(0db) Data Connections (sockets) Eternal devices (USB) 4 USB A (compatible with USB 1.1 and later) 1 USB B (compatible with USB 1.1 and later) 1 LAN Ethernet Standard PC mouse and keyboard (for data entry) Supported printers: Standard PCL3 printers (HP, Epson, Canon) Input Specifications TB 100uVrms at ma. gain for 0dB reading Mic.2 CD TF (side panel) TF (front panel) Wave files 100uVrms at ma. gain for 0dB reading 7mVrms at ma. gain for 0dB reading Input impedance : 47KOhm 100uVrms at ma. gain for 0dB reading 100uVrms at ma. gain for 0dB reading Plays wave file from hard disk drive Output Specifications FF1 & 2 7Vrms at min. 2KOhm load Left & Right Ins. Left & Right Bone Ins. Mask Monitor(side panel) 60-10000Hz -3dB 2 3Vrms at 32 Ohms / 1.5Vrms at 8 Ohms load Display Compatible software Dimensions (LWH) Weight 5,7 inch high resolution color display 640480 piels Diagnostic Suite - Noah, OtoAccess and XML compatible 36.5 29.5 6.5 cm / 14.4 11.6 2.6 inches 3.3kg/6.3lb Power supply 100-240 V~, 50-60Hz ma 0.5A Operation environment Temperature: 15-35 C Re. Humidity: 30-90% Non condensing Transport and storage Transport temperature: -20-50 C Storage temperature: 0-50 C Re. Humidity: 10-95% Non condensing