L G Davison*, BSc C Barlow, PhD, MIOA M Ashmore, RHAD, MIOA R Weinstein, RHAD Southampton Solent University Faculty of Maritime and Technology

Similar documents
Air conduction hearing thresholds of young and older Japanese adults for pure tones from 125 Hz to 16 khz

Recommended Procedure. Industrial Audiometry

Recommended Procedure. Industrial Audiometry

Minimum Training Guidelines Surveillance Audiometry

ISO INTERNATIONAL STANDARD

Signals, systems, acoustics and the ear. Week 1. Laboratory session: Measuring thresholds

THESIS PRESENTATION. The Reference Equivalent Threshold Sound Pressure Level (RETSPL) values of the Creare headphones

ISO INTERNATIONAL STANDARD

Hearing Conservation Services Specifications

Optimal Design: Bekesy Test for Mobile

VALIDITY OF DIAGNOSTIC COMPUTER-BASED AIR AND FOREHEAD BONE CONDUCTION AUDIOMETRY

General about Calibration and Service on Audiometers and Impedance Instruments

TOWN OF FAIRFIELD PUBLIC HEALTH NURSING. MANUAL: School Health APPROVED BY: Board of Health School Medical Advisor

User Guide. For Jacoti Hearing Center Pro Version 1.0. Manufacture Year 2017

Quick Guide Binaural REM

Current practices in noise health surveillance

MA 25 Operating Manual

INTRODUCTION TO PURE (AUDIOMETER & TESTING ENVIRONMENT) TONE AUDIOMETERY. By Mrs. Wedad Alhudaib with many thanks to Mrs.

Model Safety Program

IEC/TC 29 Electroacoustics. Status: September 2010

AS/NZS :2014. Occupational noise management AS/NZS :2014. Part 4: Auditory assessment. Australian/New Zealand Standard

Operating Instructions MA 25

$ 530 $ 800 $ HARDWARE SET a. HARDWARE SET b. HARDWARE SET c. Samsung Galaxy J2. Sennheiser HD280 Pro. Headphones.

A Novel Software Solution to Diagnose the Hearing Disabilities In Human Beings

OIML R 122 Annex C RECOMMENDATION. Edition 1999 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

Audiometric Techniques Program in Audiology and Communication Sciences Pediatric Audiology Specialization

Audiology Assessment. 0c. Exam type:

Oscilla - excellence since 1960

Musicians With Conventional Noise Notches Have Poorer Extended High Frequency Sensitivity

R R R HARDWARE SET a. HARDWARE SET b. HARDWARE SET c. Samsung Galaxy J2. Sennheiser HD280 Pro. Headphones.

GRASON-STADLER HEARING ASSESSMENT SYSTEMS

Recommended Procedure. Pure-tone air-conduction and boneconduction threshold audiometry with and without masking

GSI AUDIOSTAR PRO CLINICAL TWO-CHANNEL AUDIOMETER

Unlock. your potential. Otometrics Madsen A450 the audiometer that works for you N O A H P M M R E P O R T I N G H I T C O U N S E L I N G

Scope of Practice for Audiometrists

Guidance on Identifying Non-Routine Cases of Hearing Loss

Organisation Internationale de Métrologie Légale

myaudiometer. It s familiar, and it s so much

Alternative Designs Report

Santa Clarita Community College District HEARING CONSERVATION PROGRAM. Revised

FACE THE MUSIC: A BEFORE AND AFTER STUDY OF THE HEARING ACUITY OF CLASSICAL MUSIC STUDENTS

Facing the Music: Helping classical musicians comply with the Control of Noise at Work Regulations

Test-Report No.:

User Manual. - Pro Edition -

User Manual. - Pro Edition -

Title: Evaluation of the Kuduwave 5000 audiometer for compliance with standards for hearing conservation purposes

Any Qualified Provider Where are we now?

Neuro-Audio Version 2010

AUDIOMETERS AUDIXI 10

The registration testing for audiometric device in CFDA

COPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN ISO :1998

AA-M1C1. Audiometer. Space saving is achieved with a width of about 350 mm. Audiogram can be printed by built-in printer

Documentation, Codebook, and Frequencies

CITY OF FORT BRAGG HEARING CONSERVATION PROGRAM

Paediatric Certificates Information Booklet June 2017

Anatomy of the Ear. Hearing Screening and Audiometer Tutorial. The speaker has no conflict interest to declare

ER75 Electro-Acoustic Ear Simulator. Operating Manual

ISO INTERNATIONAL STANDARD

NHS or Private Hearing Aids? Find out which option is right for you with the Hearing Information Service s consumer guide.

Introduction to Audiology: Global Edition

PSYCHOMETRIC VALIDATION OF SPEECH PERCEPTION IN NOISE TEST MATERIAL IN ODIA (SPINTO)

Hearing Conservation Program

REFERRAL AND DIAGNOSTIC EVALUATION OF HEARING ACUITY. Better Hearing Philippines Inc.

(b) is as low as is reasonably practicable, where it is not reasonably practicable to meet the standard under clause (a).

A three-frequency audiogram for use in industry

AMBCO 1000+P AUDIOMETER

Handheld OAE-Tympanometry Combination System

Hearing Conservation Program

ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE VEMP ECochG MLR P300

ISO INTERNATIONAL STANDARD. Acoustics Audiometric test methods Part 2: Sound field audiometry with pure-tone and narrow-band test signals

PROPOSED REGULATION OF THE BOARD OF HEARING AID SPECIALISTS. LCB File No. R February 29, 2000

Procedure Number 310 TVA Safety Procedure Page 1 of 6 Hearing Conservation Revision 0 January 6, 2003

UNITY 2. a state-of-the-art audiological integrated diagnostic and fitting system

TAMPA ELECTRIC COMPANY ENERGY SUPPLY HEARING CONSERVATION PROGRAM

Vision Painting Inc. Safety Management System

Proceedings of Meetings on Acoustics

Equinox 2.0 PC-based audiometer. Not just an audiometer - A full counseling and reporting solution

Sound exposure and the hearing of musicians

Clinical evaluation of a computerized self-administered hearing test

SOFTWARE INSTRUCTION MANUAL

Impact of the ambient sound level on the system's measurements CAPA

PROPOSED REGULATION OF THE BOARD OF HEARING AID SPECIALISTS. LCB File No. R July 6, 2001

The effects of using personal listening devices on hearing

Aalborg Universitet. Published in: International Journal of Audiology. Publication date: Link to publication from Aalborg University

Hearing loss amongst classical music students

Contents. 1) Purpose ) Policy ) Definitions ) Procedure a) Requirements b) Noise standard... 4

HEARING CONSERVATION PROGRAM

How to Use InSituGram

OAE Test System. Screener PLUS. Diagnostic PLUS. with 4 frequency DPOAE testing Protocols

Pediatric Hearing Screening Training for the PCA. Gouverneur Healthcare Services 227 Madison Street New York, NY 10002

TRAINING MANUAL. AVANT The Perfect Screening Audiometer AIR+

Clinical Validation of the AMTAS Automated Audiometer Robert H Eikelboom 1,2,3, De Wet Swanepoel 1,2,3, Shahpar Motakef 1,2,4, Gemma S Upson 1,2

Standard Audiograms for the IEC Measurement Procedure

AMBCO AUDIOMETER

Contents. QuickSIN.. 15 Hearing Loss Simulator Master Hearing Aid Printing Limited Warranty.. 20 #0086.

MEASUREMENTS AND EQUIPMENT FOR AUDIOLOGICAL EVALUATIONS

User Guide. For Jacoti Hearing Center Version 1.1. Manufacture Year 2016

HEARING CONSERVATION PURPOSE

Audiology Equipment p r o d u c t s c AtA l o g u E

Transcription:

Effectiveness of a New Tablet Based Hearing Screening System Compared to Traditional Audiometry, Among a Cohort of Individuals With a High Incidence of Hearing Loss August 7, 213 L G Davison*, BSc C Barlow, PhD, MIOA M Ashmore, RHAD, MIOA R Weinstein, RHAD Southampton Solent University Faculty of Maritime and Technology *Point of contact: Lee.Davison@solent.ac.uk

Abstract Improvements to the intervention structure for hearing aid patients are being considered, in the form of an innovative new touch-screen tablet based hearing test. The concept behind this test is a lightweight web based software component, installed on a calibrated computer and headphone combination. The purpose of this paper is to test and validate the system to define its ability to offer accurate screening. To do this, a cohort of individuals with a high rate of hearing loss was chosen; a group of 6+ aged subjects from a local care home on the south coast. Each individual underwent an audiometric evaluation, using both the traditional audiometer, and the Tablet system, and the results compared. The results showed that there was a 6.1 db average difference between audiogram points on the tablet compared to the Maico MA51. This is in comparison to 5.7 db that was previously identified when comparing two other traditional audiometers to the same MA51. This is well within specification of the intended use of the Tablet based screener, as a precursor to further hearing specialist intervention. 1. Introduction Traditionally there is only one easy way to administer hearing screening tests to people; full audiometry. While audiometry has a long standing record (dating back to 188 [5]), and is considered the gold standard in hearing assessment, it suffers from some practical flaws. One particular flaw is the variation in performance that can be experienced due to differing headband tensions, and different calibration schedules. The biggest flaw however is the fact that a qualified audiometrist needs to be present to administer the test. This makes the test quite expensive, particularly time consuming, and compared to an automated test such as a blood pressure test, difficult to organise. Improvements to the current hearing impairment intervention structure are being considered that will lead to overall better patient care. One of the ways in which this can be achieved is by increasing the frequency and availability of hearing testing, so that more people can be accurately diagnosed. Due to the inability of the current amount of audiologists to cope with the extra demand from a greatly increased level of testing, a technological solution was sought to reduce the time and cost demands from an increased testing regime. The subject of this study is to ascertain the efficacy of a new touch-screen automated screening system, developed by Audiology-Online. The premise of the system is to provide a preliminary test to inform patients of a potential hearing issue before they commit to booking a full audiological test. This will increase the availability of effective screening, not only leading to an increased number of patients with access to treatment, but also categorising patients so that audiologists can concentrate time and resources on individuals with real otological problems. This will help make the intervention system more efficient, and can lead to a higher level of patient care. 1

2. Methods 2.1. Procedure tone at 6 dbhl, to determine if the individual s loss is such to prevent them hearing the standard tone presentations. This acts as a safety tone so that users with good hearing are not exposed to loud sounds un- The audiometry was conducted on all of the subjects in the morning of the test necessarily. day. The audiometry section of the test was performed to BSA (British Society of Audiology) standard procedure, beginning with otoscopy, and using the 2 down, 1 up method during the actual test[4]. This procedure is also based on that specified by BS EN ISO 8253-1[2], and therefore fulfils both recommended procedures. The audiometry was also carried out by two trained individuals who had taken the BSA Industrial Audiometry certification. Audiograms and otoscopy notes were recorded and filed for each individual. The Tablet test was administered in the afternoon session, and due to the nature of the intuitive touch interface was minimally supervised. The system operates in the following way: The user presses the start button on the screen in order to start the test. They are then prompted to enter their name, date of birth, and GP, which in this case was a test individual. This is to allow the relevant medical professional to receive the test results, and then organise further testing or referral as necessary. The test then begins, with a series of questions to define if the subject has contra-indications to their access into the Direct Access Adult Hearing Service. These questions are alerted to the medical professional receiving the test results to allow them to make an informed decision on the route of referral. Next the test prompts if the subject can hear a tone, by playing in one ear only. At this stage the headphones can be reversed if they have been placed incorrectly, and a screen prompt declares this. The system then plays a test After this the test begins in earnest, wherein the individual is asked to count the amount of tones that can be heard at different frequencies, while the system reduces the tone presentation from 6 dbhl to 2 dbhl, or 8 dbhl to 45 dbhl if the user responded that they could not hear the 6 dbhl test tone previously. After repeating the tone presentations for the following frequencies; 25 Hz, 5 Hz, 1 khz, 2 khz, 4 khz and 6 khz, the user is prompted that the test is finished, it sends the results to the GP, and then resets ready for the next individual. The subjects were then invited to make comment on the test procedure, and how they found it, compared to traditional audiometry. 2.2. Ethics This study achieved ethical approval from the ethics committee at Southampton Solent University on 25/6/213. The study aimed to include a cohort of individuals with a higher than average occurrence of hearing loss, in order to provide data that would be relevant to a hearing screening system with operating amplitude levels of 2 dbhl to 8 dbhl. With this in mind, a care home was chosen on the south coast, with access to individuals ages 6+ with hearing difficulties. The subjects were chosen by the care home manager, with no gender or age selection bias other than the 6+ requirement. The subjects were as follows: 2

Subject Gender Age D.O.B. 1 F 63 6/8/5 2 M 92 1/11/21 3 F 71 9/12/41 4 F 83 8/15/29 5 F 9 3/2/23 6 M 89 3/21/24 7 F 9 2/6/23 8 M 93 1/15/2 9 F 91 7//21 Table 1: Complete list of screening test subjects, 3 male, 6 female. 2.3. Equipment The study is a simple comparison of the resulting output of the tablet system compared to a traditional audiometer. The tablet system consists of an Acer W7 Tablet computer, running Windows 8, and a pair of Beyerdynamic DT77 circum-aural headphones. The tablet computer is set up to run customised web software produced by Audiology-Online Ltd, which allows tone presentation at different frequencies in the audiometric bands (25 Hz, 5 Hz, 1 khz, 2 khz, 4 khz, and 6 khz), and calibration of headphones and computer system combinations to the British Standard output levels. The Tablet system was calibrated by the use of an IEC artificial ear manufactured by Larson Davis (model number AEC21, with a type 2 adaptor), to the headphone output levels specified in the British Standard for Sennheiser HDA2 headphones[1]. This is due to the standardising work having not commenced for a generic profile for circumaural headphone designs, though this work is planned in the future to refine this calibration process. The audiometer used to compare the tablet to was the Maico MA51, which holds a current traceable calibration certificate from a suitable laboratory. An otoscope was also used in the audiometry process on each individual. All participants read and understood an information form detailing the aims of the study, and signed a consent form. 3

3. Results The full results table is produced in appendix A. 2 Mean and Standard Deviation of Differences (db) 15 5-5 125 25 5 2 4 8 (Hz) Average Differences in Bands Overall Average Differences Figure 1: A graph showing the average and standard deviation of difference in each frequency band, and the total average error 4

15 14 13 12 11 Delta Mean (db) 9 8 7 6 5 4 3 2 1-1 125 25 5 2 4 8 Audiometers Delta Mean Tablet Delta Mean Figure 2: A graph showing the average differences of the Tablet and the Maico MA51, and two other audiometers and the Maico MA51. 25 5 2 4 6 Total Average difference 7.3 6.5 4.7 6.1 6.1 5.8 6.1 Table 2: The average differences between the tablet system and traditional audiometry in the audiometric bands 4. Discussion As can be seen from the table and graph on page 5, the average difference between the Tablet system and traditional audiometry is 6.1 db. This margin or error is perfectly acceptable in the context of a screening system, especially considering the test takes around half the time of the traditional audiometry test, takes minimal to no supervision to conduct, and is designed as a precursor to further traditional intervention. 5

In order to accurately compare the outcome of this trial with the typical level of variability experienced in traditional audiometry, data from a previous experiment can be considered [3]. In this study, a group of 11 people were tested with a different audiometer, at the same time of the day and week, over 3 weeks. For the purposes of this paper, these data were then compared to the respective output of the Maico MA51, the audiometer that was used as the comparison in this study. The mean differences (Delta) between the Tablet and the MA51, and other audiometers and the MA51 were then plotted, on the graph on page 5. This comparison shows that the mean differences in any given band between the Tablet system and MA51 are within one standard deviation of the differences one can expect from comparing normal audiometers, and is even a lower mean difference in the 6 khz band. Comparing the total average errors across the spectrum, the Tablet achieves 6.1 db, while the comparison of traditional audiometers produces 5.7 db. This result, while very slightly higher, fits within the general level of variance attributable to audiometers. The shape of the curve on figure 1 (page 4) shows that there is more likely to be a larger difference in the low and high frequency ranges. This is to be expected, and is likely due to headphone placement variability, causing a resonance at low frequency, and suffering from directivity effects at high frequency. One issue that arose while testing is a misunderstanding of the Tablet test procedure. When the test prompts the user to count the amount of tones, two of the test subjects read the instruction incorrectly, and were counting the 6 db safety tone As the first presentation of the test to count. This issue has since been corrected in the test software, however the audiograms for test subjects 1 and 7 have been corrected for this error, and the revised versions used in the calculations of differences. Both the originals and corrected versions are available in the appendices. Probably the largest source of error in this study was the low overall grasp of the test elements. Due to the nature of care home residents, some subjects found both the traditional audiometry test and the Tablet System difficult to understand, and therefore introduced a variable to the test. This may account for the high levels of congruence seen between the two different system tests on some individuals, and the slightly more erratic traces seen on others. Further testing would be advisable to establish if there is a higher success rate among younger candidates with hearing impairment. There is also a large variable in the form of physical differences between individuals, such as head size and shape, seating position, presence of a high backed chair (wheelchair), etc, all of which could impact the headphone placement and concentration level of the subjects, leading to test variance. Test subjects were all hearing aid equipped when entering the experiment, which proves that they had been administered traditional audiometry in the past, which would have made it more familiar to them. This may explain the slightly higher rate of difference between the Tablet system and the MA51, which may prove to negligible if tested on inexperienced patients, or younger subjects better able to understand the nature of the Tablet test. The worst level of congruence between the two systems seen on any single audiogram is that of subject 1. In the amended form, the average difference between the two systems is 12.1 db, a difference of 3.8 db above the next highest, subject 8, at 8.3 db. Omitting this outlier from the test beings the average down to a mere 5.3 db. 6

5. Appendices A. Subject Audiograms - 2 3 4 5 6 7 8 9 1 12 125 25 5 2 4 8 Figure 3: Audiogram comparison for subject 1 7

- 2 3 4 5 6 7 8 9 1 12 125 25 5 2 4 8 Figure 4: Audiogram comparison for subject 2 8

- 2 3 4 5 6 7 8 9 1 12 125 25 5 2 4 8 Figure 5: Audiogram comparison for subject 3 9

- 2 3 4 5 6 7 8 9 1 12 125 25 5 2 4 8 Figure 6: Audiogram comparison for subject 4

- 2 3 4 5 6 7 8 9 1 12 125 25 5 2 4 8 Figure 7: Audiogram comparison for subject 5 11

- 2 3 4 5 6 7 8 9 1 12 125 25 5 2 4 8 Figure 8: Audiogram comparison for subject 6 12

- 2 3 4 5 6 7 8 9 1 12 125 25 5 2 4 8 Figure 9: Audiogram comparison for subject 7 13

- 2 3 4 5 6 7 8 9 1 12 125 25 5 2 4 8 Figure : Audiogram comparison for subject 8 14

- 2 3 4 5 6 7 8 9 1 12 125 25 5 2 4 8 Figure 11: Audiogram comparison for subject 9 15

B. Audiograms Amended for Counting Error - 2 3 4 5 6 7 8 9 1 12 125 25 5 2 4 8 Figure 12: Amended audiogram comparison for subject 1 16

- 2 3 4 5 6 7 8 9 1 12 125 25 5 2 4 8 Figure 13: Amended audiogram comparison for subject 7 17

18 C. Full Table of Results TABLET TRADITIONAL Subject 25 5 2 4 6 25 5 2 4 6 1 L 7 5 55 3 4 35 L 6 55 65 3 4 55 R 45 45 5 3 3 4 R 75 7 65 45 5 65 2 L L 8 8 85 8 R 6 7 75 5 75 R 65 75 75 65 7 85 3 L 55 6 55 7 8 L 6 55 55 65 8 R 55 5 65 7 6 8 R 55 55 6 7 7 8 4 L 6 75 75 7 L 75 75 75 65 6 85 R R 1 5 1 5 5 12 5 L 5 6 6 7 75 7 L #N/A 65 5 65 65 8 R 3 4 4 6 75 75 R #N/A 35 35 6 8 8 6 L 5 6 6 6 65 65 L 5 45 6 5 55 75 R 5 6 6 5 65 65 R 5 45 5 45 7 7 7 L 3 25 25 25 35 55 L 3 25 25 25 45 6 R 3 4 25 3 45 4 R 3 3 25 2 5 6 8 L 3 3 3 55 L 15 15 2 45 5 R 4 35 4 8 R 15 25 3 75 95 8 9 L 5 5 6 5 6 65 L 45 45 5 45 6 75 R 6 6 65 65 7 8 R 65 6 55 6 75 75 1a L 75 55 6 35 45 4 L 6 55 65 3 4 55 R 5 5 55 35 35 45 R 75 7 65 45 5 65 2a L 25 2 2 2 3 5 L 3 25 25 25 45 6 R 25 35 2 25 4 35 R 3 3 25 2 5 6 Tablet Based Hearing Screening System Table 3: Full table of results (#N/A denotes missing data, a gap represents the tablet reading >8 dbhl)

References [1] Acoustics - Reference zero for the calibration of audiometric equipment. Part 8: Reference equivalent threshold sound pressure levels for pure tones and circum-aural earphones, 24. [2] Acoustics - Audiometric test methods. Part 1: Pure tone and bone conduction autiometry (ISO 8253-1:2), 2. [3] L G Davison et al. Variances in the audiogram data of individuals undertaking audiometry on different calibrated audiometers. Unpublished, 213. [4] British Society of Audiology. Recommended procedure - pure-tone air-conduction and bone conduction threshold audiometry with ans without masking. British Society of Audiology Website, 211. [5] SDG Stephens. The british medical profession and the first audiometers. J Laryngol Otol, 95:1223 35, 1981. 19