MRI Exams in Patients with Non MR Conditional Pacemakers and with MR Conditional Pacemakers

Similar documents
MRI and CIEDs. Disclosures

MRI for Patients with MRI-Conditional Pacing System: Radiographers Role. Lawrance Yip DM, DR, QMH

Micra MC1VR01. MRI procedural information for Micra Model MC1VR01 MR Conditional single chamber transcatheter pacing device (VVIR)

MRI SureScan pacemakers & ICDs what you need to know

STANDARD OPERATING PROCEDURE (SOP)

Lead Management for MRI

Initial Experience with a Radiologist-Managed MR Imaging Cardiac Pacemaker Program in an Academic-Affiliated Community Hospital

Safety Issue of Static Magnetic Field (1)

MRI Guidelines for the Axonics Sacral Neuromodulation System

MRI imaging for patients with cardiac implantable electronic devices (CIEDs)

Q & A: How to Safely Scan Patients with a SureScan MRI Pacemaker

Advisa MRI and Ensura MRI SureScan pacing systems

MRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System

*smith&nephew. MRI Safety Information & Parameters for Smith & Nephew Orthopaedics AG. Knee Implants

VNS Therapy System Physician s Manual

*smith&nephew. MRI Safety Information & Parameters for Smith & Nephew Orthopaedics AG. Shoulder Implants

MRI GUIDELINES FOR INSPIRE THERAPY

Perioperative Management of Cardiac Implantable Devices

Cardiac Rhythm Therapy // Advanced Features // ProMRI. ProMRI. Checklist and Quick Reference Guide

Devices and EP- Safety in MRI

Protocol. This trial protocol has been provided by the authors to give readers additional information about their work.

Safety of MRI at 1.5 Tesla in Patients with Implanted Sacral Nerve Neurostimulator

Supplemental Material

MRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System

Key words: Decision-making processes; case study; MRI with pacemaker; A&E. ASEAN J. Sci. Technol. Dev., 32(2):

MRI in Patients with Pacemakers and Defibrillators. Paul A. Friedman, MD Win K Shen, MD Robert E. Watson, Jr. MD, Phd October 2016

2014 AAPM 56 th Annual Meeting

MRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System

Version überholt. Nicht verwenden. Version obsolète. Ne pas utiliser. Versione obsoleta. Non utilizzare. Verouderde versie. Niet gebruiken.

NORTH OF ENGLAND CARDIOVASCULAR NETWORK (NECVN)

MRI GUIDELINES FOR INSPIRE THERAPY

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System

9/5/17. Anesthetic considerations for patients with implanted devices for treating chronic pain and more. Objectives:

8/2/2017. Acknowledgement. Disclaimer. How to manage radiotherapy patients with CIED from initial consult to treatment: TG203 recommendations

IMAGEREADY MR CONDITIONAL PACING SYSTEM

Implant Procedure Concepts

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500)

Everyone Needs a Device Christopher L. Fellows, MD, FACC, FHRS Virginia Mason Medical Center Seattle, Wa.

Peri-operative management of pacemakers and implantable cardiac defibrillators

Safety of Pacemakers and Defibrillators in Electromagnetic Navigation Bronchoscopy

MRI ACCESS. Evera MRI SureScan ICD Systems

2009 CPT Codes for Cardiac Device Monitoring

*smith&nephew. MRI Safety Information & Parameters for Smith & Nephew Orthopaedics AG. Hip Implants

JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE w Vol. 5, No. 2, pp , 2003

Cardiac Rhythm Management // Manual // ProMRI. ProMRI. MR conditional device systems

Procedure for exceptional magnetic resonance scanning in patients with standard (non-mr-conditional) pacemakers

Cardiovascular magnetic resonance with an MR compatible pacemaker

09/05/2018. True/False: All pacemakers have defibrillation capabilities.

EXAMPLE PROTOCOL FOR PATIENT SCANNING PROCESS

MR in Patients with Pacemakers and ICDs: Defining the Issues

Algovita. MRI Procedure Guidelines. Spinal Cord Stimulation System. 201x

INTERPRETING THE ECG IN PATIENTS WITH PACEMAKERS

UnitedHealthcare Medicare Advantage Cardiology Prior Authorization Program

Safety and Imaging Quality of MRI in Pediatric and Adult Congenital Heart Disease Patients with Pacemakers

Leadless pacing. P.E. Vardas Professor of Cardiology University of Crete, Greece

Warning: Patients should not be exposed to MRI environments until the surgical site following pump implantation is fully healed.

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500)

Emergency Department Management of Patients with Implantable Cardioverter Defibrillators

MEDICAL POLICY Cardiac Event Monitors/ Cardiac Event Detection

Yes, out of sight out of mind.

Low-Profile Wrist Fixator. For stabilization of fractures of the distal radius.

EnTrust D154VRC Single Chamber ICD 35J delivered 8 seconds BOL, 11.8 seconds ERI 10.7 years**** 35cc, 68g Programmable Active Can

AspireSR. Essential information about your new device

Call Medtronic at 1 (800) to verify the patient s current implanted system

Procedure for the Reprogramming of Pacemakers (PPMs) Prior to Elective and Emergency Surgery

Specific Basic Standards for Osteopathic Fellowship Training in Cardiology

2010 MRI Safety Update: Codes & Standards. Who Is This Guy? Full Disclosure

CARDIOLOGY. 3 To develop in the trainees the humanistic, moral and ethical aspects of medicine.

ImageReady MRI Full Body Guidelines for Precision Montage MRI Spinal Cord Stimulator System

ImageReady MRI Head Only Guidelines for Spectra WaveWriter Spinal Cord Stimulator System

AHA Scientific Statement

Pediatric pacemakers & ICDs:

Model 5392 EPG Temporary Pacer

HEART OF THE MATTER: cardiac issues in safe endoscopy & sedation

Parkinson s disease, Essential Tremor and primary dystonia

MRI Information for Medtronic Spinal and Biologics Devices

Aneurysm Clips: Evaluation of Magnetic Field Interactions With an 8.0 T MR System

Electromagnetic Interference between External Defibrillator and Cardiac Resynchronization Therapy-Pacemaker (CRT-P) Devices

Building physician referrals and improve patient care for an aging population with

MRI Guidelines for VNS Therapy

Review of Pacemakers and ICD Therapy: Overview and Patient Management

A patient s step by step guide to Magnetic Resonance Imaging

MRI conditional devices. A luxury or a real clinical need? Sophie Mavrogeni, MD, FESC Onassis Cardiac Surgery Center, Athens, Greece

Read this manual before performing an MRI scan on a patient implanted with an Algovita Spinal Cord Stimulation System.

2010 Canadian Cardiovascular Society/ Canadian Heart Rhythm Society Training and Maintenance of Competency in Adult Clinical Cardiac

CARDIAC DEVICE MR-CONDITIONAL PRODUCT SUMMARY CHART

Cardiovascular Technology Profession Statement

856 Unintentional Deactivation of ICDs Mayo Clin Proc, August 2002, Vol 77 Figure 1. Case 3. Printout from Guidant programmer (Guidant Corp, St Paul,

MRI Safety Information for the HiRes Ultra 3D Cochlear Implant

Need to Know: Implantable Devices. Carolyn Brown RN, MN, CCRN Education Coordinator Emory Healthcare Atlanta, Georgia

Magnetic resonance imaging of pacemakers and implantable cardioverter-defibrillators without specific absorption rate restrictions

Strokes After TAVR: Perspectives from the US CoreValve Trials

Flowchart for ICD patients undergoing Surgery or procedures involving diathermy/magnetic fields

PATIENT CARE AND MRI SAFETY Module 7

Leadless Pacing. Osama Diab Assistant Prof. of Cardiology Ain Shams University Egypt

MEDTRONIC CARELINK NETWORK FOR PACEMAKERS. Comparison between the Medtronic CareLink Network for Pacemakers and Transtelephonic Monitoring

UnitedHealthcare, UnitedHealthcare of the River Valley and Neighborhood Health Partnership Cardiology Notification and Prior Authorization Program:

It is estimated that after implantation, up to 75% of patients. Original Research

BRITISH HEART RHYTHM SOCIETY GUIDELINES FOR THE MANAGEMENT OF PATIENTS WITH CARDIAC IMPLANTABLE ELECTRONIC DEVICES (CIEDs) AROUND THE TIME OF SURGERY

SPORTS AND EXERCISE ADVICE IN PATIENTS WITH ICD AND PPM

Transcription:

MRI Exams in Patients with Non MR Conditional Pacemakers and with MR Conditional Pacemakers Frank G. Shellock, Ph.D., FACC Adjunct Clinical Professor of Radiology and Medicine Keck School of Medicine, University of Southern California Director for MRI Studies of Biomimetic MicroElectronic Systems National Science Foundation, Engineering Research Center University of Southern California Institute for Magnetic Resonance Safety, Education, and Research www.mrisafety.com Shellock R & D Services, Inc., www.mrisafety.com www.imrser.org MRI SAFETY

Disclosure Unrestricted educational and/or research grants provided by the following: Metrasens, Johnson and Johnson, Cordis, DePuy, Edwards Laboratories, Codman, Cook, Inc., Mednovus, Covidien, Bracco Diagnostics, Advanced Bionics, Abbott Laboratories, Bard, B. Braun, Ethicon, SuperDimension, Teleflex, Medtronic Orthopedics, Smith & Nephew Shellock R & D Services, Inc., www.mrisafety.com MRI SAFETY

FACTORS RESPONSIBLE FOR MRI INCIDENTS AND ACCIDENTS Missile effect Incorrect, outdated, lack of screening Implants and devices Outdated or inappropriate policies Shellock R & D Services, Inc., www.mrisafety.com

Implants and Devices Magnetic field interactions MRI related heating Induced currents Operational/functional disturbances, damage Artifacts Shellock R & D Services, Inc., www.mrisafety.com

Each Factor May Impact a Patient with Cardiac Pacemaker Undergoing MRI Shellock R & D Services, Inc., www.mrisafety.com

Terminology: Implants and Devices Developed by ASTM International ASTM International Designation: F 2503 05. Standard Practice for Marking Medical Devices and Other Items for Safety in the Magnetic Resonance Environment In 2005, adopted and applied by the FDA Radiology 2009; 253:26 30 Shellock R & D Services, Inc., www.mrisafety.com Download www.imrser.org

Implants and Devices: Terminology MR Safe no hazards in all MRI environments MR MR Conditional no hazards in specified MRI environment, MRI labeling info typically found in the Instructions for Use MR MR Unsafe hazards in all MRI environments MR Shellock R & D Services, Inc., www.mrisafety.com

Electronically Activated Implants MR Conditional labeling (U.S. and Europe) exists for. Bone Fusion Stimulator Programmable Infusion Pumps Cochlear Implants Neurostimulation Systems Cardiac Pacemakers/ICD Shellock R & D Services, Inc., www.mrisafety.com

Electronically Activated Implants MRI Conditions and Device Requirements Include: Static Magnetic Field Strength (1.5 T, 3 T) Frequency for RF (64 MHz, 128 MHz) Type of Transmit RF Coil Acceptable SAR Level Other MRI Conditions Implant Configuration or Placement Scenario (i.e., patient positioning relative to transmit RF coil) Special Programming Shellock R & D Services, Inc., www.mrisafety.com

Cardiac Pacemakers Possible MRI Issues Movement or vibration of pulse generator Excessive lead heating Temporary or permanent functional changes EMI causing interference and/or arrhythmias

10/2012 >1,500 pts.

MRI and Non-MR Conditional Cardiac Pacemakers There is considerable evidence in the peer reviewed literature, from in vitro and clinical reports, that it is safe to perform MRI exams under highly specific conditions.

In Vitro Studies Non-MR Conditional Cardiac Pacemakers Shellock FG, O'Neil M, Ivans V, Kelly D, O'Connor M, Toay L, Crues JV. Cardiac pacemakers and implantable cardioverter defibrillators are unaffected by operation of an extremity MR imaging system. AJR Am J Roentgenol. 1999 Jan;172:165-70. Shellock FG, Fieno DS, Thomson LJ, Talavage TM, Berman DS. Cardiac pacemaker: in vitro assessment at 1.5 T. Am Heart J. 2006;151:436-43 Shellock FG, Fischer L, Fieno DS. Cardiac pacemakers and implantable cardioverter defibrillators: in vitro magnetic resonance imaging evaluation at 1.5-tesla. JCMR. 2007;9:21-31. Shellock R & D Services, Inc., www.mrisafety.com

Clinical Studies Non-MR Conditional Cardiac Pacemakers Safe MRI Exams at 0.5-T 51 patients Pacemaker pre and post MRI Monitoring with cardiologist, ECG, pulse oxymetry, capnography No pacing dysfunction/ arrhythmias, or reprogramming Sommer et al. Radiology 2000 215(3):869-79

Non-MR Conditional Cardiac Pacemakers Safe MRI Exams at 1.5-T 54 patients 62 studies: cardiac, general exams (SAR 0.08 2.0 W/kg) No exclusions; No special programming prior to MRI Devices interrogated before and after MRI Patients continuously monitored during MRI No adverse events occurred; No studies interrupted 40 ( 37%) leads had changes 2 (1.9%) leads required a change in output None were significan Martin, Coman, Shellock et al (JACC 2004;43:1315 24)

Non-MR Conditional Cardiac Pacemakers Safe MRI Exams at 1.5-T 115 exams (non thoracic, one vendor) No pacer dependent patients Pre and post exam interrogation Monitoring with cardiologist, ECG, pulse oxymetry, capnography No pacing dysfunction/ arrhythmias, reprogramming Small increase in pacing capture threshold, but not clinically significant at 0, 3 month f/u Sommer et al. Circulation; 2006 114(12) 1285-92)

Non-MR Conditional Cardiac Pacemakers Safe MRI Exams at 1.5-T 438 pts (pacemakers and ICDs), 555 MRI exams Blood pressure, electrocardiography, oximetry, and symptoms were monitored by a nurse with experience in cardiac life support and device programming who had immediate backup from an electrophysiologist. With appropriate precautions, MRI can be done safely in patients with selected cardiac devices. Because changes in device variables and programming may occur, electrophysiologic monitoring during MRI is essential. Nazarian S, et al. Ann Intern Med. 2011;155(7):415-24

Non-MR Conditional Cardiac Pacemakers Safe MRI Exams at 1.5-T 109 pts (pacemakers and ICDs), 125 MRI exams Control group of 50 pts, no MRI MRI in patients with cardiac devices resulted in no device or lead failures. A small number of clinically relevant changes in device parameter measurements were noted. However, these changes were similar to those in a control group of patients who did not undergo MRI. Cohen et al. Am J Cardiol 2012 Aug 23. [Epub ahead of print]

Guidelines for MRI in Patients with Non MR Conditional Pacemakers -Establish risk:benefit, obtain consent -Cardiologist/EP specialist -Programmer, interrogate pre and post -ACLS certified personnel and equipment -Certain MR procedures (e.g., head/brain) -Specific MRI conditions, limit RF -Monitor patient during MRI (ECG, 0 2 sat, BP) -Be prepared to intervene Martin et al., Roquin et al., Loewy et al.,, ACC/AHA (2007)

Shinbane, et al. JCMR, 2007

Non-MR Conditional Cardiac Pacemakers Essentially off label use Team effort is required Specially trained healthcare professionals Specific conditions and guidelines required Monitoring, be prepared for emergencies

Non-MR Conditional Cardiac Pacemakers Issues All MRI and pacemaker interactions have not been fully characterized Risk/Benefit appears to be acceptable for strong clinical indications for MRI

Non-MR Conditional Cardiac Pacemakers

MR Conditional Cardiac Devices Shellock R & D Services, Inc., www.mrisafety.com

MR Conditional Cardiac Pacemakers AJR Am J Roentgenol. 2011 Sep;197:W457 9.

MR Conditional Pacemakers Now available for patients needing MRI exams Specially trained healthcare professionals Specific conditions and guidelines required Only one (Medtronic) available in the U.S., with scan limitations Shellock R & D Services, Inc., www.mrisafety.com

MR Conditional Cardiac Devices Lobodzinski Cardiology Journal 2012;19(1):98-104.

MR Conditional Pacemaker U.S. Shellock R & D Services, Inc., www.mrisafety.com

MRI and MR Conditional Pacemakers General Limitations Cardiac devices available for new patients only (must remove both old PG and leads entirely if replacing with MR conditional device, with new PG and leads) Patients must wait for 6 weeks prior to MRI Restrictions regarding MRI procedures, scanning over the thorax and SAR levels (this may change) MR conditional cardiac devices still require special screening and training personnel, monitoring, etc.

MRI Safety Resource www.mrisafety.com MRI safety information The List information for thousands of objects Search engine Email address Shellock R & D Services, Inc. 2011