Mono- and Disaccharides

Similar documents
Carbohydrates in Food

Iodide in Milk. Electrochemistry Discover the difference

Application Note. Authors: C. Ledesma, M. Gibert, J.R. Gibert Ingenieria Analitica S.L. Extracts from various food products

Bisphenol A in Drinking Water

ANTEC LEYDEN. Analysis of Carbohydrates in Food and Beverages using Anion-Exchange Chromatography and Pulsed Amperometric. Introduction.

Analysis of Lactose and isomers in Lactose-free labelled products

Betadex Sulfobutyl Ether Sodium according to USP

columns CarboPac PA20 Column

Betadex Sulfobutyl Ether Sodium According to USP

Glycoprotein monosaccharide analysis using HPAE-PAD with manually prepared eluent

The Determination of Sugars in Molasses by High-Performance Anion Exchange with Pulsed Amperometric Detection

Determination of Carbohydrates in Kombucha Using HPAE-PAD

Determination of Plant-Derived Neutral Oligo- and Polysaccharides Using the CarboPac PA200

Application Note. Sensitive analysis of the lactose content of lactose-free labelled products using HPAEC-PAD. Summary.

A HPAE-PAD Chromatographic Assay for Carbohydrates in Urine as a Measure of Intestinal Permeability

Separation of Saccharides Using TSKgel Amide-80, a Packing Material for High-performance Normal Phase Partition Chromatography (2) Table of Contents

Carl Fisher, Terri Christison, Hua Yang, Monika Verma, and Linda Lopez Thermo Fisher Scientific, Sunnyvale, CA, USA

HPLC Analysis of Sugars

Sugar analysis according to the EU Regulation using amperometric detection and Metrosep Carb 2-150/4.0

Thermo Scientific Dionex CarboPac MA1 Column

Oligosaccharide Analysis by High-Performance Anion- Exchange Chromatography with Pulsed Amperometric Detection

Separation of Saccharides Using TSKgel Amide-80, a Packing Material for High-Performance Normal Phase Partition Chromatography (1) Table of Contents

LC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D

HC-75 Calcium Form. 305 x 7.8 mm HC-75 Calcium Form (P/N 79436)

Separation of Saccharides Using TSKgel Amide-80, a Packing Material for High Performance Normal Phase Partition Chromatography (2)*

Unequalled durability against water elution. % tr

Hypersil BDS and Hypersil Classical HPLC Columns

Aminothiols and Disulfides

Catalogue. Resins and Columns For High Performance Liquid Chromatography

Analysis - Carbohydrate analysis

Separation of 15 Underivatized Saccharide and Sialic Acid USP Standards

CarboPac PA-100 Column for Oligosaccharide Analysis

Articaine & Epinephrine Injection According to USP Method

HPAE-PAD Determination of Infant Formula Sialic Acid

Application Note. Abstract. Author. Biotherapeutics & Biosimilars. Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany

Determination of Sucralose Using HPAE-PAD

Determination of Carbohydrates in Beverages and Milk Products by HPAE-PAD and Capillary HPAE-PAD

UNISON UK - Amino For Aqueous Elutions and Exceptional Separation Balance

Confident, lower-pressure analysis of carbohydrates, alcohols, and organic acids. Agilent Hi-Plex Ligand-Exchange HPLC Columns

Product Guide for LudgerSep TM R1 HPLC Column for Glycan Analysis

Product Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis

Determination of Plant-Derived Neutral Oligo- and Polysaccharides

Metanephrines. in Urine. Clinical & Diagnostics Analysis. Introduction. Application Note ALEXYS - Clinical & Diagnostics

Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis

Thermo Scientific Dionex CarboPac PA100 Column

Oligosaccharide Profiling of O-linked Oligosaccharides Labeled with 2 Aminobenzoic Acid (2-AA)

Serotonin in Urine. Electrochemistry Discover the difference

Product Manual for Dionex CarboPac MA1, PA1, PA10 and PA100 Columns

Hyderabad, India. Department of Pharmaceutical Chemistry, Glocal University, Saharanpur, India.

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Thermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific

Sugars in Honey Using HPAE-PAD: What Is the Best Column?

A New Stability-Indicating and Validated RP-HPLC Method for the Estimation of Liraglutide in Bulk and Pharmaceutical Dosage Forms

Determination of Sucralose in Reduced- Carbohydrate Colas using High-Performance Anion-Exchange Chromatography with Pulsed Amperometric Detection

A. Incorrect! No, this is not the description of this type of molecule. B. Incorrect! No, this is not the description of this type of molecule.

Direct Determination of Sialic Acids in Glycoprotein Hydrolyzates by HPAE-PAD

The Determination of Carbohydrates, Alcohols, and Glycols in Fermentation Broths

GlycanPac AXR-1 Columns

Converting a CHP Method for Insulin to Agilent Poroshell 120 Columns

Pelagia Research Library

USP purity analysis of pravastatin sodium using the Agilent 1120 Compact LC

High-Performance Anion-Exchange Chromatography with Pulsed Amperometric Detection (HPAE-PAD) Carbohydrates Analysis Application Notebook

Development, Estimation and Validation of Lisinopril in Bulk and its Pharmaceutical Formulation by HPLC Method

HVA, VMA and 5-HIAA in Urine

Serotonin in Plasma. Electrochemistry Discover the difference. Summary. Application Note Clinical & Diagnostics

Estimation of Emtricitabine in Tablet Dosage Form by RP-HPLC

Agilent Anion-Exchange Media for Proteins - Loading vs Resolution - Effect of Flow Rate and Example Protein Separations

Questions- Carbohydrates. A. The following structure is D-sorbose. (Questions 1 7) CH 2 OH C = O H C OH HO C H H C OH

Ion Chromatography: A Versatile Technique for the Analysis of Beer

Online 2D-LC Analysis of Complex N-Glycans in Biopharmaceuticals Using the Agilent 1290 Infinity 2D-LC Solution

Product Guide for LudgerSep TM C3 anion exchange HPLC Column for Glycan Analysis

Qualitative and quantitative determination of phenolic antioxidant compounds in red wine and fruit juice with the Agilent 1290 Infinity 2D-LC Solution

Analytical and Preparative SFC Columns

Chapter 1. Chemistry of Life - Advanced TABLE 1.2: title

GlycanPac AXH-1 Columns

SACCHARIDES (Liquid Chromatography)

Rapid and Direct Analysis of Free Phytosterols by Reversed Phase HPLC with Electrochemical Detection

Separation of Macrocyclic Lactones (Avermectins) on FLARE C18 MM & FLARE C18+ Columns

[ APPLICATION NOTE ] Profiling Mono and Disaccharides in Milk and Infant Formula Using the ACQUITY Arc System and ACQUITY QDa Detector

Development and Validation of a Simultaneous HPLC Method for Quantification of Amlodipine Besylate and Metoprolol Tartrate in Tablets

Analysis of Food Sugars in Various Matrices Using UPLC with Refractive Index (RI) Detection

ISSN: ; CODEN ECJHAO E-Journal of Chemistry 2011, 8(3),

Carbohydrates 1. Steven E. Massey, Ph.D. Assistant Professor Bioinformatics Department of Biology University of Puerto Rico Río Piedras

Quantitative Analysis of Carbohydrates and Artificial Sweeteners in Food Samples Using GFC- MS with APCI Interface and Post-column Reagent Addition

SeQuant ZIC -HILIC For all who expect more...

Biochemistry: Macromolecules

Journal of Chemical and Pharmaceutical Research

RP-HPLC Analysis of Temozolomide in Pharmaceutical Dosage Forms

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit

Sialic Acid Determination in Glycoproteins: Comparison of Two Liquid Chromatography Methods. Experimental. Introduction. Method 1.

Determination of Clinically Relevant Compounds using HPLC and Electrochemical Detection with a Boron-Doped Diamond Electrode

Sepax Technologies, Inc.

SIMULTANEOUS ESTIMATION OF VALSARTAN AND HYDROCHLOROTHIAZIDE IN TABLETS BY RP-HPLC METHOD

Determination of Benzoate in Liquid Food Products by Reagent-Free Ion Chromatography

METHOD DEVELOPMENT AND VALIDATION BY RP-HPLC FOR ESTIMATION OF ZOLPIDEM TARTARATE

Iodine HPLC Assay. Catalog Number: IOD34-H Tests For Research Use Only. Not for use in diagnostic procedures.

Reverse Phase HPLC Analysis of Atomoxetine in Pharmaceutical Dosage Forms

OCR (A) Biology A-level

Pelagia Research Library

Transcription:

Application Note Food/Beverage/Life Sciences The finest LC-EC Applications for Food & Beverage analysis Mono- and Phenols Bisphenol A Catechins Flavonoids Phenols Antioxidants Resveratrol Epicatechin Quercetin Other polyphenols Carbohydrates Monosaccharides Lactose Other oligo- and polysaccharides Vitamins, minerals etc. A, C, D, E, and K Iodide Q10, ubiquinols n Mono- and disaccharides in food & life sciences n ALEXYS Carbohydrate Analyzer with AEC n Pulsed Amperometric Detection (PAD) n Flow cell with Au working electrode n Sensitive and selective analysis Summary In this publication the analysis of monosaccharides and other carbohydrates is demonstrated using an ALEXYS LC-EC analyzer based on the new DECADE Elite electrochemical detector. The method is based on separation by HPAEC in combination with PAD using a 4-step potential waveform. ALEXYS Application Note # 220_003_02 Electrochemistry Discover the difference

Introduction Carbohydrates (also called saccharides) are the most abundant biomolecules in nature and play an important role in many physiological processes (metabolism, storage of energy, structure etc.) and nutrition. Complex carbohydrates (oligo- and polysaccharides) are composed of monosaccharides that are covalently linked by glycosidic bonds, either in the α or β form. Due to the presence of hydroxyl groups which can be oxidized, carbohydrates can be detected using pulsed amperometric detection with pico- and femtomol sensitivity [2-4]. The analysis of carbohydrates is of interest to the food industry but also many fields in life sciences. One important field is glycomics [1]. Glycomics covers a range of scientific disciplines that are applied to study the composition, structure and function of carbohydrates in biologic systems. High Performance Anion Exchange Chromatography in combination with Pulsed Amperometric Detection (HPAEC-PAD) can be used as a tool for the compositional analysis of monosaccharides in glycoproteins. It allows the quantification of the amount of individual monosaccharides and screening for compositional changes in glycosylation in proteins. The CarboPac PA20 (3 x 150 mm) Anion-Exchange column with a guard column was chosen for the method evaluation. In case of samples containing amino acids or small peptides, like in glycoproteins, an additional AminoTrap column (3 x 30 mm) must be installed between the injector and the guard column. The use of an Aminotrap column will affect the peak performance (slight increase in retention time and peak width). All chromatograms are recorded without AminoTrap column unless otherwise stated. Table 1 LC-EC conditions HPLC ALEXYS LC-EC Analyzer with low-pressure mobile phase selector Column CarboPac PA20 150 x 3 mm ID analytical column + CarboPac PA20 30 x 3 mm ID guard column. Mobile phase Flow rate Vinjection Temperature Flow cell Potential waveform (4-step) 10 mm sodium hydroxide (analysis), 200 mm sodium hydroxide (column regeneration). 0.5 ml/min 10 µl (Full loop) I-cell about 0.5 µa ADF Range 30 C for separation & detection VT-03 with Au WE, stainless steel AE and HyREF TM (Pd/H 2 ) RE, spacer 50 µm E1, E2, E3, E4: +0.1, -2.0, +0.6, -0.1 V ts, t1, t2, t3, t4: 0.2, 0.4, 0.02, 0.01, 0.07 s 0.5 Hz 1 or 2 µa/v Method Separation Under alkaline conditions (ph > 12) carbohydrates can be separated by means of HPAEC. Carbohydrates are weak acids with pka values ranging between 12 and 14. At high ph they will be either completely or partially ionized depending on their pka value. Due to the extreme alkaline conditions only polymeric anion-exchange columns are suitable for carbohydrate separation. The retention time of carbohydrates is inversely correlated with pka value and increases significantly with molecular weight. The elution order of carbohydrates on such anion-exchange columns is usually as follows: sugar alcohols elute first, followed by mono-, di-, tri-, and higher oligosaccharides. Figure 1: ALEXYS Carbohydrate analyzer for isocratic HPAEC (mono- and disaccharides). The analysis is based on a step-gradient, see Table 2. At a concentration of 10 mm NaOH, carbonate ions (C032-) present in the mobile phase will bind strongly to the active sites of the stationary phase resulting in a loss of retention and column efficiency. A column clean-up/regeneration step after isocratic elution with 200 mm NaOH is therefore necessary to remove the bound carbonate ions and other contaminants like amino acids/peptides. This regeneration step assures reproducible retention behavior for each run. The LC-EC system was equipped with only one pump and a Vici electrically-actuated low pressure (LP) valve in the pump LP suction line to switch between mobile phase and the solution for column clean-up. Table 2 Step-gradient program Time (min) Mobile phase Description 0 10 10 mm NaOH Isocratic elution & detection 10 20 200 mm NaOH Column clean-up/regeneration 20 50 10 mm NaOH Re-equilibration to starting conditions 2

To minimize the introduction of carbonate ions in the mobile phase the eluents were carefully prepared manually using a carbonate-free 50% w/w NaOH solution (commercially available). The diluent was deionized water (resistivity >18 MΩcm) which was sonificated and sparged with Helium 5.0 prior to use. The mobile phase should be prepared in plastic bottles instead of glass. NaOH is a strong etching agent and will react with the inner glass wall resulting in the release of silicates and borates. The appropriate amount of 50% w/w NaOH solution was carefully pipetting into the diluent under gently stirring and Helium sparging to prepare the required the mobile phase solutions. The bottles with mobile phase and column clean-up solution were blanketed with Helium (0.2 bar overpressure) during the analysis to minimize the build-up of carbonate ions in the mobile phase and to assure a reproducible analysis. Results In Figure 3 a chromatogram is shown of a 10 µl injection of a 10 µm standard mix of 7 mono-saccharides in water obtained with the HPAEC-PAD system using the specified conditions in Table 1 and 2. All compounds elute within 10 minutes, the total run time is 50 minutes due to the step-gradient program to regenerate and re-equilibrate the column, which is repeated every run. Detection For the pulsed amperometric detection of monosaccharides and other carbohydrates a VT-03 electrochemical flow cell is used for this evaluation. This flow cell has an Au working electrode (WE), HyREF (Pd/H2) reference electrode (RE) and stainless steel auxiliary electrode (AE). A 4-step potential waveform is applied as shown in Figure 2. Figure 3: Chromatogram of a 10 µl injection of a 10 µm standard mix of 7 monosaccharides in water: (1) L-Fucose, (2) 2-Deoxy-D-Glucose, (3) Galactosamine, (4) Glucosamine, (5) Galactose, (6) Glucose and (7) Mannose. Figure 2: 4-step PAD potential waveform for the detection monosaccharides and other carbohydrates. The temperature for separation and detection was set to 30 C. The cell current was typical about 0.5 µa with these PAD settings under the specified conditions. This particular 4-step waveform with a pulse duration of 500 ms has been claimed to have as benefits: (1) a consistent long-term peak area response and (2) minimal electrode wear [5]. Note that an ALEXYS LC-EC system with the new DECADE Elite electrochemical detector is required for PAD detection using a 4-step potential waveform. This standard mix represents a group of monosaccharides (hexoses and aminohexoses) commonly found in glycoproteins. Glycoproteins are proteins containing oligosaccharide chains (glycans) covalently attached to the polypeptide sidechain by glycosylation. HPAEC-PAD can be used as a tool for the compositional analysis of monosaccharides in glycoproteins. It allows the quantification of the amount of individual monosaccharides and screening for compositional changes in glycosylation in proteins. To release the monosaccharides from the glycan chains acid hydrolysis with TFA and/or HCl is performed prior to HPAEC-PAD analysis. It is evident from Figure 3 that all relevant monosaccharides are well separated (R 1.8) with peak efficiencies in the range of 4500 7000 theoretical plates, which demonstrates the suitability of the system for the compositional analysis of glycoproteins. The peak table of the chromatogram in Figure 3 is shown in Table 3. 3

Table 3 Table 4 Peak table (10 µl injection of a 10 µm standard mix of 7 monosaccharides in water) Compound tr (min) (na) Capacity Eff (th.pl) Resolution Tailing Fucose 2.65 941.5 2.2 4630-1.28 2-Deoxy-D- Glucose 3.94 594.2 3.8 6324 7.3 1.29 Galactosamine 4.48 1182.8 4.4 6264 2.6 1.17 Glucosamine 5.39 630.6 5.5 4792 3.4 1.07 Galactose 5.93 505.1 6.1 7001 1.8 1.13 Glucose 6.67 437.7 7.0 6702 2.4 1.14 Mannose 7.70 325.1 8.3 6997 3.0 1.35 Limit of Detection (LOD), based on a 100 nm standard Compound Fucose 5 2-Deoxy-D-Glucose 8 Galactosamine 4 Glucosamine 7 Galactose 9 Glucose 10 Mannose 12 LOD (nmol/l) Linearity, repeatability and LOD The linearity was investigated in the concentration range of 1-10 µmol/l. In this concentration range the linearity is excellent and correlation coefficients for peak area were better than 0.999 for all monosaccharides. In the low concentration range between 10 100 nmol/l the correlation coefficients were 0.99 for all compounds. The Limit of Detection (LOD) for all monosaccharides are shown in Table 4. The LOD s were calculated as the analyte response corresponding to 3x the ASTM noise (average peak-to-peak baseline noise of 30 segments of 0.5 min). The responses of a chromatogram obtained with a 100 nm standard mix were used to calculate the LOD. Concentration detection limits of the monosaccharides were in the range of 4 12 nmol/l, which corresponds to 40 120 fmol on-column. To demonstrate the good detection sensitivity of the ALEXYS HPAEC-PAD system a chromatogram of a 10 µl injection of a 10 nm standard mix is shown in Figure 4. Time [Min.] Figure 4: Chromatogram of a 10 µl injection of a 10 nm standard mix of 7 monosaccharides in water: (1) L-Fucose, (2) 2-Deoxy-D-Glucose, (3) Galactosamine, (4) Glucosamine, (5) Galactose, (6) Glucose and (7) Mannose. The relative standard deviation (RSD) of the retention time and peak area were determined for 10 replicate injections of a low and high concentration monosaccharides standard in water. The results are shown in Table 5. RSD s for retention time were 0.3%. For the peak areas the RSD s were < 1% for all monosaccharides in the 10 µm standard and < 2% for the 100 nm standard. These data demonstrate that with this method reproducible analysis of monosaccharides can be achieved. 4

Table 5 Repeatability 10 µl injections of a 10 µm and 100 nm monosaccharides standard in water (n=10) Compound 10 µmol/l standard 100 nmol/l standard Retention time Area Retention time Area Fucose 0.16 0.34 0.68 0.20 1.44 1.31 2-Deoxy-D- Glucose 0.26 0.33 0.65 0.19 1.90 0.82 Galactosamine 0.23 0.43 0.59 0.16 1.28 1.30 Glucosamine 0.28 0.50 0.59 0.18 1.64 0.86 Galactose 0.30 0.63 0.76 0.20 1.97 1.34 Glucose 0.29 0.65 0.70 0.23 1.37 1.17 Mannose 0.30 0.35 0.73 0.28 1.95 1.22 Analysis of other mono- and disaccharides To demonstrate the versatility of the HPAEC-PAD method for the analysis of carbohydrates, also another mix of mono- and disaccharide standards was analyzed, see Figure 5 below. This standard contains a mix of carbohydrates among which relevant sugars used as probes in intestinal permeability studies (mannitol, lactulose and xylose). In such diagnostic studies these non-metabolized (inert) sugars are orally administered and the urinary recovery determined. With this non-invasive approach intestinal damage can be assessed in both humans and animals. HPAEC-PAD offers a selective and sensitive method for the quantification of these sugars (and other carbohydrates commonly found) in urine, without requiring sample pre-treatment or (post-column) derivatization [7]. Table 6 Peak table (10 µl injection of a 10 µm standard mix of 10 mono- and disaccharides in water) Compound tr (min) (na) Capacity Eff (th.pl) Resolution Tailing Mannitol 1.50 1449 0.8 2805-1.42 Fucose 2.42 981 1.9 4659 7.2 1.22 2-Deoxy-D- Glucose 3.45 631 3.2 6562 6.6 1.35 Arabinose 4.21 590 4.1 7208 4.2 1.23 Glucosamine 4.63 757 4.6 4282 1.8 1.08 Sucrose 5.80 411 6.0 6085 4.0 1.13 Xylose 6.35 485 6.7 8042 1.9 1.13 Fructose 7.10 250 7.6 7602 2.5 1.33 Lactose 11.38 410 12.7 7540 10.1 1.08 Lactulose 12.67 308 14.3 7614 2.3 1.19 The peak table of the chromatogram in Figure 5 is shown in Table 6. Conclusion The ALEXYS Carbohydrates Analyzer based on the new DECADE Elite detector provides a selective and sensitive analysis solution for the analysis of mono- and disaccharides. At 10 µl injection volume LOD s in the range of 5 10 nmol/l has been obtained, which demonstrates the excellent detection sensitivity of the system. Figure 5: Chromatogram of a 10 µl injection of a 10 nm standard mix of 10 mono- and disaccharides in water: (1) Mannitol, (2) Fucose, (3) 2-Deoxy-D- Glucose, (4) Arabinose, (5) Glucosamine, (6) Sucrose, (7) Xylose, (8) Fructose, (9) Lactose and (10) Lactulose. 5

References 1. K.F. Aoki-Kinoshita, An introduction to Bioinformatics for Glycomics, PLoS Comput Biol, vol 4 issue 5 (2008), 1-6 2. D.C. Johnson, D. Dobberpuhl, R. Roberts, P. Vandeberg, Review: Pulsed amperometric detection of carbohydrates, amines and sulfur species in ion chromatography- the current state of research, J. Chromatogr., 640 (1993), 79-96 3. D.C. Johnson, W.R. LaCourse, LC with pulsed ECD at gold and platinum, Anal. Chem., 62 (1990), 589A 597 4. W.R. LaCourse, Pulsed Electrochemical Detection in High Performance Liquid Chromatography, John Wiley & Sons, New York, 1ed, 1997 5. R.D. Rocklin, A.P. Clarke, M. Weitzhandler, Improved longterm reproducibility for pulsed amperometric detection of carbohydrates via a new quadruple-potential waveform, Anal. Chem, 70 (1998), 1496 1501 6. Antec, Carbohydrates in food, Application note, 220.002 rev. 04 7. S.H. Sørensen, F.J. Proud, A. Adam, H.C. Rutgers, R.M. Batt, A novel HPLC method for the simultaneous quantification of monosaccharides and disaccharides used in tests of intestinal function and permeability, Clin. Chim. Acta, 221 (1993), 115-124 Ordering information 180.0054E ALEXYS Carbohydrate analyzer (1 Channel) including column and flow cell 250.0033E LP solvent selector option, 4-port,1/4-28 250.1078 CarboPac PA20 analytical column, 150 x 3.0 mm ID 250.1079 CarboPac PA20 guard column, 50 x 3.0 mm ID 250.1085 AminoTrap column, 50 x 3.0 mm ID Distributor: ERC GmbH +49 89 66055696 Fax +49 89 60824826 partner@erc-hplc.de www.erc-hplc.de For research purpose only. The information shown in this communication is solely to demonstrate the applicability of the ALEXYS system. The actual performance may be affected by factors beyond Antec s control. Specifications mentioned in this application note are subject to change without further notice. www.myantec.com 6