Abstract. Med. J. Cairo Univ., Vol. 77, No. 3, June: , MAGDA S. AZER, M.D.

Similar documents
Multi-center (5 centers); United States and Canada. September 10, 1992 to April 9, 1993

Study Of Effects Of Varying Durations Of Pre-Oxygenation. J Khandrani, A Modak, B Pachpande, G Walsinge, A Ghosh

End-tidal control vs. manually controlled minimal-flow anesthesia: a prospective comparative trial

Chapter 25. General Anesthetics

Comparison of Ease of Insertion and Hemodynamic Response to Lma with Propofol and Thiopentone.

Soda lime temperatures during low-flow sevoflurane anaesthesia and differences in dead-space.

British Journal of Anaesthesia 96 (6): (2006) doi: /bja/ael092 Advance Access publication April 13, 2006 Emergence and recovery in childr

Evaluation of Postoperative Complications Occurring in Patients after Desflurane or Sevoflurane in Outpatient Anaesthesia: A Comparative Study

Agent consumption with the Zeus in the automated closed circuit anesthesia mode with O 2 /air mixtures

ABSTRACT. Alexandria Journal of Anaesthesia and Intensive Care INTRODUCTION. AJAIC-Vol. (9) No. 1 Marsh 2006

January 27, 1992 to November 26, A total of 120 patients (60/site) were enrolled in the study as follows: PATIENT ENROLLMENT

NITROUS OXIDE ELIMINATION AND DIFFUSION HYPOXIA DURING NORMO- AND HYPOVENTILATION

Effect of Vecuronium in different age group

Cricoid pressure: useful or dangerous?

General Anesthesia. Mohamed A. Yaseen

Inhalational Anesthesia. Munir Gharaibeh, MD, PhD, MHPE School of Medicine The University of Jordan February, 2018

Pharmacokinetics. Inhalational Agents. Uptake and Distribution

Table showing induction time (seconds) among studied groups Induction time (Seconds)

Veena Mathur, Deepak Garg, Neena Jain, Vivek Singhal, Arvind Khare, Surendra K. Sethi*

SINGLE BREATH INDUCTION OF ANAESTHESIA WITH ISOFLURANE

ISPUB.COM. Review Of Currently Used Inhalation Anesthetics: Part II. O Wenker SIDE EFFECTS OF INHALED ANESTHETICS CARDIOVASCULAR SYSTEM

A comparison of endotracheal intubation and use of the laryngeal mask airway for ambulatory oral surgery patients Todd D W

Effect of Charcoal Filter on the Emergence from Sevoflurane Anesthesia in a Semi-Closed Rebreathing Circuit

Pharmacology: Inhalation Anesthetics

ANAESTHESIA EDY SUWARSO

Regional versus general anesthesia in patients underwent hip fracture surgery over 80 years old: A retrospective cohort study

Dexamethasone Compared with Metoclopramide in Prevention of Postoperative Nausea and Vomiting in Orthognathic Surgery

Agency 71. Kansas Dental Board (Authorized by K.S.A and (Authorized by K.S.A and

Low flow anaesthesia: economic, eco friendly and effective

Abstract. Introduction

Comparison of isoflurane and sevoflurane for short-term anesthesia in piglets

The use of laryngeal mask airway in dental treatment during sevoflurane deep sedation

A Comparative Study for the Lung Mechanics during One-Lung Ventilation in Thoracic Surgeries Using Two Different Modes of Mechanical Ventilation

Kinetics and Monitoring of Inhaled Anesthetics. Copyright , James H Philip, all rights reserved

Capnography. Capnography. Oxygenation. Pulmonary Physiology 4/15/2018. non invasive monitor for ventilation. Edward C. Adlesic, DMD.

Cuffed Tracheal Tubes in Children - Myths and Facts. PD Dr. Markus Weiss Department of Anaesthesia University Children s Hospital Zurich Switzerland

HST-151 Clinical Pharmacology in the Operating Room

Crresponding Author: * Gurpreet Singh

Inhalation anesthesia. Somchai Wongpunkamol,MD Anes., CMU

A Protocol for the Analysis of Clinical Incidents September Incident Summary: failure to administer anaesthetic gas at start of operation

Anesthesia Monitoring. D. J. McMahon rev cewood

Anaesthetic Plan And The Practical Conduct Of Anaesthesia. Dr.S.Vashisht Hillingdon Hospital

The Effect of Bispectral Index Monitoring on Anesthetic Use and Recovery in Children Anesthetized with Sevoflurane in Nitrous Oxide

MYASTHENIA GRAVIS AND SEVOFLURANE

Bronchoscopes: Occurrence and Management

Propofol or etomidate: Does it genuinely matter for induction in cardiac surgical procedures?

Comparison of the Hemodynamic Responses with. with LMA vs Endotracheal Intubation

The effect of a pediatric heat and moisture exchanger on dead space in healthy pediatric anesthesia

STATE OF OKLAHOMA 2014 EMERGENCY MEDICAL SERVICES PROTOCOLS

GE Healthcare. Non Invasive Ventilation (NIV) For the Engström Ventilator. Relief, Relax, Recovery

ISSN X (Print) Research Article. *Corresponding author Dr. Souvik Saha

End-tidal Control. Introduction. GE Healthcare

G. MORIWAKI, H. BITO AND K. IKEDA. Summary. Patients and methods. British Journal of Anaesthesia 1997; 79:

WILAflow Elite Neonatal Ventilator. Non-invasive treatment for the most delicate patients.

Downloaded from armaghanj.yums.ac.ir at 21: on Thursday November 29th 2018

Pilot Of Spontaneous Breathing Vs. Ventilated Model For Hemorrhage And Resuscitation In The Rabbit

Test Bank Pilbeam's Mechanical Ventilation Physiological and Clinical Applications 6th Edition Cairo

Type of intervention Anaesthesia. Economic study type Cost-effectiveness analysis.

INTUBATING CONDITIONS AND INJECTION PAIN

INTUBATION/RSI. PURPOSE: A. To facilitate secure, definitive control of the airway by endotracheal intubation in an expeditious and safe manner

Use of the Intubating Laryngeal Mask Airway

CONTINUOUS POSITIVE AIRWAY PRESSURE (CPAP) DEFINITION

Don t let your patients turn blue! Isn t it about time you used etco 2?

Paediatric neuraxial anaesthesia asleep or awake, what is the best for safety?

AVAS trial. Automated control of mechanical ventilation during general anaesthesia. Study protocol. A bicentric prospective observational trial

I. Subject: Continuous Positive Airway Pressure CPAP by Continuous Flow Device

Comparison of the Optimal Effect-site Concentrations of Remifentanil for Preventing Cough during Emergence from Desflurane or Sevoflurane Anaesthesia

Comparison of patient spirometry and ventilator spirometry

Bispectral index (Bis) guided comparison of control of haemodynamic responses by fentanyl and butorphanol during tracheal intubation in neurosurgical

Sevoflurane Output in the Isoflurane/Halothane Diamedica Draw-over Vaporiser

Capnography Connections Guide

Physiological normal values (Depends on age, strain, health status, type of anesthesia, etc.)

Anaesthetic considerations for laparoscopic surgery in canines

pat hways Medtech innovation briefing Published: 16 September 2014 nice.org.uk/guidance/mib10

Oral Midazolam for Premedication in Children Undergoing Various Elective Surgical procedures

AVOIDING THE CRASH 3: RELAX, OPTIMAL POST-AIRWAY MANAGEMENT AVOIDING THE CRASH: OPTIMIZE YOUR PRE, PERI, AND POST AIRWAY MANAGEMENT

NI 60. Non-invasive ventilation without compromise. Homecare Pneumology Neonatology Anaesthesia. Sleep Diagnostics Service Patient Support

GUIDELINES ON CONSCIOUS SEDATION FOR DENTAL PROCEDURES

Capnography for Pediatric Procedural Sedation Learning Module Last revised: February 18, 2014

5 Respiratory sites of action of propofol: absence of depression of peripheral chemoreflex loop by low dose propofol

Family Feud SPA Myron Yaster, MD

TO THE OPERATOR AND PERSON IN CHARGE OF MAINTENANCE AND CARE OF THE UNIT:

Clinical safety and cost analysis of Sevoflurane and Isoflurane in surgical patients

ETCO2 MONITORING NON-INTUBATED PATIENTS

A Comparative Study of Classic LMA and Proseal LMA in Paralyzed Anaesthetized Patients

Bronchial mucus transport velocity in patients receiving desflurane and fentanyl vs. sevoflurane and fentanyl

Accumulation of foreign gases during closed-system anaesthesia

BRITISH BIOMEDICAL BULLETIN

Hypotension after induction, corrected with 20 mg ephedrine x cc LR EBL 250cc Urine output:

Capnography: The Most Vital of Vital Signs. Tom Ahrens, PhD, RN, FAAN Research Scientist, Barnes-Jewish Hospital, St. Louis, MO May, 2017

HEMODYNAMIC PROFILE DURING LAPAROSCOPIC CHOLECYSTECTOMY VERSUS LAPAROSCOPIC BARIATRIC SURGERY

Optimal Effect-Site Concentration of Remifentanil for Inhibiting Response to Laryngeal Mask Airway Removal during Emergence

Does inhalational nitrous oxide affect induction dose of propofol and haemodynamic?

End Tidal CO2 Not All Its Cracked Up To Be The Limitations of PETCO2 In Sedation Analgesia

ENDOTRACHEAL INTUBATION POLICY

WILAflow Elite Neonatal Ventilator. Non-invasive treatment for the most delicate patients.

3/30/12. Luke J. Gasowski BS, BSRT, NREMT-P, FP-C, CCP-C, RRT-NPS

Survey of the sevoflurane sedation status in one provincial dental clinic center for the disabled

Neostigmine as an adjunct to Bupivacaine, for caudal block in burned children, undergoing skin grafting of the lower extremities

Transcription:

Med. J. Cairo Univ., Vol. 77, No. 3, June: 71-77, 009 www.medicaljournalofcairouniversity.com Evaluation of Target-Controlled Inhalational Anesthesia in Pediatrics Using the Newly Introduced Zeus Anesthesia Workstation: A Prospective Clinical Study MAGDA S. AZER, M.D., FIPP* The Department of Anesthesia & Pain Management, National Cancer Institute, Cairo University. Abstract Background: The optimal inhalational induction should provide titration of inhaled anesthetics to imply a fast and reliable alteration without overshooting the targeted inhaled agent concentration and involves a stable desired drug level. The recent option of target-controlled inhalation anesthesia was made possible by the introduction of Zeus anesthesia workstation. The aim of this study was to evaluate the targetcontrolled inhalational anesthesia in pediatrics using the Zeus anesthesia machine in comparison to the classic technique with the conventional anesthesia machine using sevoflurane. Methods: In this prospective, controlled, clinical study, we randomized 40 children undergoing elective oncological surgery under general anesthesia into equal groups to receive either target-controlled inhalational induction with sevoflurane through Zeus anesthesia machine [Target-controlled group (TC)], or to be induced classically with inhalation of sevoflurane through Fabius-CE conventional anesthesia machine (control group). Time to loss of conscious, wash in, washout times, time to target ETsevo and emergence time were recorded. Number of adjustments to reach the target sevoflurane concentration and overshooting was also recorded. Results: Mean time to attain and maintain target concentration (time to target TT) was significantly shorter in the target controlled group (TC 104 ±4.6 sec Vs control 10 ± 19.8 sec). A significantly longer emergence time was obtained in the control group (16.1 ±.4min) versus (7.8±.6min) in. In addition number of adjustments to target ETsevo was higher in control group (7± 1.5 in control group Vs 1 ±0.5 in ). Overshooting to a mean ETsevo of 4.9 ±0.1% occurred in the control group after 3 min of induction, whereas no overshooting occurred in the. Mean wash in time as well as mean time to loss of conscious (TLOC) did not differ significantly in either group. Conclusion: The target controlled inhalational anesthesia using the auto-control mode of the Zeus apparatus allowed Address correspondence: Dr. Magda Shoukry Azer; MD, Anesthesia & Pain Management Department, National Cancer Institute, Cairo University, Egypt, 1 Kasr El Aini Street, Fom El Khalig, Cairo, Egypt, E-mail: magedad_magda@hotmail.com *FIPP: Fellowship of interventional pain practice. a very fast and reliable induction of sevoflurane in pediatrics with no overshoot. It also allowed minimal or no anesthetist intervention in reaching the target end-tidal sevoflurane concentration. Reduced emergence time as a result of very rapid washout times was also remarkable compared to conventional anesthesia machine. Key Words: Target-controlled inhalation Auto-control mode Zeus anesthesia machine Pediatric Sevoflurane. Introduction INHALATION agents are the cornerstone of pediatric anesthesia, as children are often induced by mask before venous access is obtained. Inhalation anesthesia is still considered to be the gold standard by the overwhelming majority of pediatric anesthetists world-wide. The potent inhalational anesthetic, sevoflurane has dominated anesthetic inductions in children for decades providing smooth induction of anesthesia with excellent outcomes. The higher costs are probably the main reason for not completely switching from halothane to sevoflurane world-wide [1,]. The optimal inhalational induction should provide titration of inhaled anesthetics to imply a fast and reliable alteration without overshooting the targeted inhaled agent concentration and involves a stable desired drug level. The conventional anesthesia machine with a classically applied outof-circle vaporizer, implies that a fast adjustment of inhaled agent concentration is only feasible by increasing the FGF resulting in a possible overshoot in inhaled agent concentrations and increased consumption [3]. The conflict between reducing agent consumption by minimizing the fresh gas flow (FGF) and gradually reaching the difference between the actual drug concentration and the target drug level would be only possible by uncoupling agent delivery and FGF. Using a principle 71

7 Evaluation of Target-Controlled Inhalational Anesthesia where an agent is directly delivered into the breathing circle system independent of FGF theoretically allows fastest alteration of agent concentration and its minimal consumption [4]. However, a recently launched anesthesia workstation allow target-controlled inhalation anesthesia (TCIA) using this principle: the Zeus anesthesia workstation (Dragër Medical, Lübeck, Germany). In adults target-controlled inhalation induction (TCII) was successfully performed with the Zeus anesthesia machine [5]. Zeus anesthesia machine was recently introduced in Egypt in Children s Cancer Hospital (CCHE) Therefore; the aim of this study was to evaluate the target-controlled inhalational anesthesia in pediatrics using the Zeus anesthesia machine in comparison to the classic technique with the conventional anesthesia machine using sevoflurane. Material and Methods The zeus apparatus: The Zeus apparatus is multifunctional in both administration modes for inhaled anesthetics and in ventilation modes. For drug delivery, two control modes are possible, fresh gas control (FGC) and auto-control (AC). In FGC mode, a classical ventilator with capacity for low-flow and an out-ofcircle vaporizer is emulated and no automated system is active. FGF and oxygen concentration are set manually, emulating the use of classical rotameters. In AC mode, multiple computerized closed-loop feedback systems can be turned on. In the AC mode with minimal FGF (e.g. 1 liter/ min), the clinician sets a targeted end-tidal concentration of inhaled anesthetic and the volatile anesthetic feedback control will obtain and maintain this targeted end-tidal concentration as accurate as possible. In full AC mode, also called 'uptake mode', anesthetic delivery, inspiratory oxygen concentration and FGF are feedback-controlled. FGF is therefore minimized towards closed-circuit conditions and will only add the required quanta of oxygen, nitrous oxide or air to maintain a given set gas mixture. The breathing system of the Zeus apparatus follows the basic structure of a classical rebreathing system (circle system), as shown in Fig. (1). The ventilator consists of an electronic driven and controlled compressor turbine placed in the inspiratory limb. Direct Injection of Volatile Anesthetic (DIVA) module; (which replaced the conventional vaporizer) is the anesthetic metering unit, which meters volatile anesthetics and FGF. The metering unit stores a quantity of anesthetic liquid. The selected volatile anesthetic is injected into a heated vaporizing chamber and the vapour is delivered to the breathing system via the supply unit using a heated pipe. Depending on the ventilator control mode, the supply unit either directly injects (auto-control (AC) mode) the saturated agent vapour into the breathing system or mixes it with the fresh gas first (fresh gas control (FGC) mode). The fabius -CE apparatus: The fabius -CE anesthesia machine (Dragër Medical, Lübeck, Germany) consists of an electrical piston-driven ventilator, an electronic mixed gas control unit and out-of-circle vaporizer to deliver the volatile anesthetic. The breathing system of the fabius -CE apparatus is a classical rebreathing system (circle system). 1 1 Fresh Gas Vol. agent 18 Man Spont P 17 11 15 16 3 4 6 M P 13 1- Non-return valve for anesthetic gas scavening line. - Airway pressure limiting valve (Man/Spont). 3- PEEP/Pmax valve. 4- Non return valve (expiration). 5- Airway pressure sensor. 6- Flow sensor (Spiro life ) (expiration). 7- Y-piece flow sensor (Alveon ). 8- Lung. 9- Flow sensor (Spiro life ) (inspiration). 10- Non return valve (inspiration). 11- Soda lime canister. 1- Safety valve. 13- Airway pressure sensor (inspiration). 14- Pressure gauge. 15- Low pressure valve. 16- Turbine. 17- Bag pressure sensor. 18- Bag. 19- Water trap. 0- Gas analyser. 1- Closed circuit valve. - Man/spont valve. Fig. (1): Schematic view of the Zeus breathing system. 10 14 0 5 P 1 9 19 8

Magda S. Azer 73 Patients and methods: After approval from research committee of our hospital and obtaining parental consents, 40 children aged 1-1 years, ASA I-III undergoing elective oncological surgery under general anesthesia were included in this prospective, randomized, controlled, clinical study. Cases with significant cardiorespiratory, renal, hepatic dysfunction were excluded. Other exclusion criteria were: expected difficult intubation, full stomach and neurological impairment. Premedication with oral midazolam 0.mg/kg was given in the preoperative holding area. Cases were randomly allocated into equal groups to receive either target-controlled inhalational induction with sevoflurane through Zeus anesthesia machine [Target controlled group (TC) group n=0 patient], or to be induced classically with inhalation of sevoflurane through Fabius-CE conventional anesthesia machine (control group n=0 patient). Heart rates (HR), electrocardiogram (ECG), pulse oximetry (SpO ), noninvasive mean arterial pressure. (MAP), end-tidal carbon dioxide (ETCO), inspired sevoflurane concentration and ETsevo concentration were monitored. After preoxygenation with 100% oxygen, the target endtidal sevoflurane (ETsevo) was set at 4% in the without priming of the circuit using the auto-control mode (AC) with minimal FGF (1L/ min). When the expired ETsevo reached 4%, the target was set to keep it at this value. In the control group induction was initiated with sevoflurane at 8% (Over pressure technique without priming of the circuit) until ETsevo reaches 4% then the vaporizer was adjusted to maintain ETsevo at this level. The fresh gas flow was adjusted according to the child s body weight with a minimum of 1L/ min. In both groups, after loss of consciousness IV line was inserted and fentanyl g/kg was injected, when the child became apneic controlled ventilation was initiated to obtain tidal volume of 10ml/kg to compensate for facial mask and tubing dead space and to monitor accurately ETsevo concentration. Atracurium 0.5mg/kg was given; three minutes later endotracheal tube was introduced. Maintenance was done by air-oxygen mixture (50% oxygen +50% air). During maintenance, the endtidal sevoflurane was adjusted to % in both groups. At the end of surgery, termination of sevoflurane administration by setting the target end-tidal sevoflurane to 0% in the and the vaporizer was shut off in the control group, washout-times were measured. Ventilation as well as FGF settings were maintained unchanged all through the operation until spontaneous respiration commenced and extubation was done in both groups. Recorded parameters: Heart rate (HR), mean arterial pressure (MAP), oxygen saturation (SpO ), end-tidal carbon dioxide (ETCO), inspired sevoflurane concentration (Fisevo%) and end-tidal sevoflurane (ETsevo%) concentration were recorded every 1min during induction and every 5 min thereafter. Number of adjustments to obtain and maintain the target ETsevo during induction. Overshoot during induction which is the highest value in end-tidal sevoflurane concentration when aiming for 4%. Duration of overshoot during induction i.e. period of time (sec) during which ETsevo is above target concentration. Sevoflurane consumption during induction is the volume in ml consumed during induction as measured by the machine (only in Zeus). All potential adverse effects were recorded. Time measurements in seconds: Wash in time; defined as time to first appearance of sevoflurane in the inspiratory circuit. Time to target (TT); defined as time to reach end-tidal sevoflurane a stable target concentration of 4%. Time to loss of consciousness (TLOC); defined as time to loss of eyelash reflex. Times to 5, 50, 75 and 90% wash-out; defined as the seconds needed after setting target end-tidal concentration to 0% to reach 5, 50, 75 and 90% reduction of ETsevo concentration respectively, (ETsevo to reach 1.5%, 1 %, 0.5%, 0.% concentration respectively). Emergence time defined as time to eye opening, first purposeful movement or first cry (whichever is earlier). Statistical analysis: Data was presented as mean and standard deviation for quantitative variables. Comparison between groups was done using Student's t-test for qualitative variables, while repeated measure analysis of variance (ANOVA) was used for repeated measures of HR, MAP, SpO, EtCO, ETsevo% and Fisevo% followed by post hoc t test with Bonferroni correction for multiple comparisons as appropriate. The chi square test was used for comparison of gender. Data obtained from the study was analyzed using the software SPSS (Statistical package for social science) version 11.0. A p value <0.05 was considered statistically significant. Results This prospective study was carried out at Children s Cancer Hospital of Egypt in the period between November 007 to June 008. All allocated cases completed the study. The two groups showed no significant difference as regard mean age; weight

74 Evaluation of Target-Controlled Inhalational Anesthesia and duration of surgery. The distribution of sex and ASA status was similar also (Table 1). There were no significant difference in respect to heart rate (HR), mean arterial pressure (MAP), oxygen saturation (SpO ), end-tidal carbon dioxide (ETCO) among the two studied groups, although mean MAP was slightly lower in the control group but this mild difference was not significant statistically (Table ). Mean wash in time as well as mean time to loss of conscious (TLOC) did not show any significant difference between the two groups. Whereas mean time to attain and maintain target concentration (time to target TT) was significantly shorter in the target controlled group in comparison to control group (TC 104±4.6 Vs control 10 ± 19.8) (Table 3). Table (1): Patients demographic characteristics, duration of surgery (min) and distribution of sex and ASA status. Variable Age (yr) Wt (kg) Male/female ASA I/II/III Duration of surgery (min) Data are presented as mean ±SD. 3.9±.1 14.6±.5 14/6 4/9/7 166±9.8 4.6± 1.9 15.3± 1.1 1/8 6/8/6 180±5 Table (): Mean values of mean arterial pressure (MAP), heart rate (HR), oxyhemoglobin saturation (SpO ), and end-tidal CO tension (EtCO ) in the two studied groups. Variable Mean emergence time was significantly longer in the control group versus the [966 ± 144 sec (16.1 ±.4min) in control Vs 468 ± 156 sec (7.8±.6min) in TC] (Table 3), as the FGF settings were maintained unchanged till the end of surgery except for one case where the FGF was increased to 6L/ min due to persistent hypotension toward the end of the surgery and rapid washout was required. The emergence time in this case was 450 sec. (This case was excluded from emergence time and washout times analysis of control group results). Number of adjustments to reach and maintain the target ETsevo was higher significantly in the control group in comparison to the (1 ±0.5 in Vs 7± 1.5 in control group). Overshooting to a mean ETsevo of 4.9 ±0.1% occurred in the control group after 3 min of induction and the ETsevo exceeded the targeted value for 60 ±4.7 sec during induction before returning to target value and stability (Fig. ). On the contrary the target controlled group didn t show any overshooting of ETsevo % during induction (Fig. 3). Times to 5, 50, 75 and 90% wash-out are presented in Fig. (4) and showed statistically significant delay in washout times in the control group in comparison to target controlled group at all recorded percentages. No significant complications were noted in any patient of the two groups apart of one case in who developed agitation during mask ventilation and resolved with the administration of fentanyl. The mean consumption of sevoflurane during induction in the as measured by Zeus anesthesia machine was 10.8 ± 0.6 ml. Sevoflurane consumption couldn t be measured in control group. Sevoflurane concentration % 7 6 5 4 3 1 0 MAP (mm Hg) 93.4±8.4 88.0± 10.4 HR (beats/min) 17.8± 15.9 19±8.5 SpO (%) 98.1 ± 1.0 98.5± 1. EtCO (mm Hg) 35.6±4.9 34.4±5.1 Data are presented as mean ±SD. Table (3): Different time phases during anesthesia. Variable 1 min. min. 3 min. 4 min. Wash in time (sec) 6.4±.5 8±.7 TLOC (sec) 80± 14.6 84± 17.4 TT (sec) 104±4.6 10± 19.8* Emergence time (sec) 468± 156 966± 144* Data are presented as mean±sd. *p<0.05 in comparison to. TT= Time to target. TLOC= Time to loss of conscious. Time Etsevo % Fisevo % 5 min. Fig. (): Mean end-tidal versus mean inspired sevoflurane concentration in the control group during induction.

Magda S. Azer 75 Sevoflurane concentration % Time (min) 5 4.5 4 3.5 3.5 1.5 1 0.5 16 14 1 10 8 6 4 0 0 1 min. min. 3 min. Time 4 min. Etsevo % Fisevo % 5 min. Fig. (3): Mean end-tidal versus mean inspired sevoflurane concentration in target controlled group during induction. 5% 50% 75% 90% Percentage washout Fig. (4): Time to percentage washout of sevoflurane in the two studied groups. Discussion Automatic closed-loop control is a system that processes information coming from the patient and the anesthesia system, compares it to a set point that defines the target output level and uses the difference to adjust the output so that the targeted set point is reached and maintained [6]. Since the ideal variable for the control of anesthetics is still searched for, anesthetists use the most famous indirect variable which is the mean arterial pressure. Another easily measurable variable is the end-tidal concentration of inhalational agents. It closely represents the brain concentration of the anesthetic agent and is available in virtually every location where inhalational anesthetics are administered without additional costs [7]. Recently, the new anesthesia machine (Zeus, Dragër Medical, Lübeck, Germany) is currently using the principle of independence of agent delivery upon the FGF. Anesthetic and fresh gas delivery is feedback-controlled by using direct injection into the breathing circle. In this study we have chosen to use the auto-control mode with minimal flow to evaluate the automatic control system in target controlled inhalational anesthesia, and the minimal flow (FGF=1L/min) was used as compound A may accumulate in the breathing system, and the recommendation that sevoflurane not to be administered with fresh gas flows lower than 1.0 l/min [8]. The first study on TCII with sevoflurane was performed with the Zeus apparatus in adults [5]. In that study TCII was successfully performed with sevoflurane highlighting several points as stability, accuracy and simplicity of the technique. The wash in time in our study was comparable between the two groups (6.4 ±.5 sec in Vs 8±.7 in control group) but was shorter than that reported in the adult study (36 sec) which may be explained by smaller volume of pediatric hoses taking less time to saturate the inspiratory circuit. Our results as regard time to loss of conscious was similar to that reported in adults target controlled inhalation induction [5]. Loss of conscious time was shorter in our study in (80 ± 14.6 sec) than a previous study using incremental induction with sevoflurane in neonates (116 sec) [9]. While Sigeston, et al. performed rapid inhalation induction with the use of 8% sevoflurane and 66% NO in pediatrics; loss of conscious time was a little bit shorter (7 sec) in the sevoflurane group [10] than that encountered in our study and that may be explained by the addition of nitrous oxide denoting that target controlled inhalational induction is almost as rapid as induction by over pressure technique and the addition of NO may add to its rapidity. Time to target fraction of sevoflurane 4% was obtained in adults after 130± 19s, however, in this study it took only 104±4.6 sec in the target controlled to reach a stable ETsevo concentration of 4%. This rapid rise of the alveolar concentrations of inhalation agents can be expected in pediatric patients compared to adults, because alveolar ventilation in younger patients is high compared to their functional residual capacity. Whereas the target ETsevo was obtained in the control group after 10 ± 19.8 sec, this was preceded by a period of overshoot (to a mean ETsevo of 4.9 ±0.1 %) during induction. The mean duration of overshoot was for 60 ±4.7

76 Evaluation of Target-Controlled Inhalational Anesthesia sec before returning to target concentration of 4%. These results coincide to those reported in an invitro study comparing the time course of sevoflurane or desflurane end-tidal concentrations in FGC mode from the Zeus apparatus with the classical Primus system [11]. In both anesthesia machines, FGC mode resulted in the largest initial overshoot in end-tidal concentration and this was similar to what occurred in our control group. In the TC group we used the auto-control mode and the results showed the shortest time to target ETsevo, no overshoot and a significant decrease in number of adjustments to reach the target concentration denoting that in this mode, the inhaled anesthetics are feedback-controlled independent from the FGF, so rapid changes in concentrations are possible [11]. The possibility of overshooting the target concentration may result in increased incidence of side effects mainly hypotension; however the mild decrease in the mean MAP that occurred in the control group was statistically insignificant. The significant decrease in number of adjustments to reach and maintain the target ETsevo in the TC group in comparison to the control group (1 ±0.5 in Vs 7± 1.5 in control group) was very much comparable to the results of the in-vitro study concluding that only few steps were required to guide drug administration in AC mode, in contrast to the manually controlled, where continuous changes in agent titration are required to reach and maintain a targeted concentration [11]. Also a previous study using automatic feedback control system to adjust end-tidal isoflurane concentration reported that it was generally faster, more stable and more accurate than human control [7]. As regard washout times our results showed statistically significant delay in washout times in the control group in comparison to target controlled group at all recorded percentages (Fig. 4). That was apparent and explained in the study of time course in-vitro comparison between the Zeus apparatus with the classical Primus system in different control modes where the AC mode was always faster in decreasing agent content of the system than fresh gas control mode in the classic anesthesia machine, revealing the ability of the auto-control mode to maximizes FGF to enhance flushing of the breathing system until the new set value is reached [11]. That would also explain the reduction in emergence time in the significantly than control group (Table 3) (as we didn t increase the FGF in either groups towards the end of surgery, which is the only feasible way to enhance agent washout in fresh gas mode). The elongated emergence time in the control group 16.1 ±.4 min was similar to the results of O Brien et al. were the emergence time (limb move) of the sevoflurane group (18:44 min: sec) was longer than other groups [9]. That could be partly explained by absence of MAC tailoring towards the end of surgery and that was also our practice in this study. The mean consumption of sevoflurane during induction in the TC group was 10.8±0.6 ml and this was in the same range reported in the adults using target controlled inhalation induction (1.3 ±.6 ml) [5]. In another study performing rapid induction with 8% sevoflurane, the agent consumption during induction was 8.5 ml [1] ; but the insertion of laryngeal mask in that study shortened the induction time to 140 sec explaining this reduced consumption. In conclusion the target controlled inhalational anesthesia using the auto-control mode of the Zeus apparatus allowed a very fast and reliable induction of sevoflurane in pediatrics with no overshoot. It also allowed minimal or no anesthetist intervention in reaching the target end-tidal sevoflurane concentration. Thus freeing the anesthetist hands for other tasks of anesthesia care. Reduced emergence time as a result of very rapid washout times was also remarkable compared to conventional anesthesia machine. The use of the autocontrol mode may optimize the course of volatile anesthetic improving patient safety, reducing anesthetist repetitive tasks. The attractive option of closed circuit conditions to reduce the cost of inhalational agents and gases is very much highlighted with the availability of the "uptake mode" in the Zeus apparatus and the need for detailed studies in this aspect is to be recommended. References 1- JÖHR M. and BERGER T.M.: Paediatric anaesthesia and inhalation agents. Best Pract. Res. Clin. Anaesthesiol., 19: 501-5, 005. - LERMAN J.: Inhalation agents in pediatric anaesthesia - an update. Curr. Opin. Anaesthesiol., 0: 1-6, 007. 3- VAGTS D.A. and LOCKWOOD G.G.: The uptake of sevoflurane during anaesthesia. Anaesthesia, 53: 86-6, 1998. 4- VERKAAIK A.P. and VAN DIJK G.: High flow closed circuit anaesthesia. Anaesth Intensive Care, : 46-34, 1994. 5- NOUETTE-GAULAIN K., LEMOINE P., CROS A.M., et al.: Induction par inhalation de sévoflurane á objectif de concentration chez l adulte avec le respirateur Zeus. Ann. Fr. Anesth. Reanim., 4: 80-806, 005. 6- O HARA D.A., BOGEN D.K. and NOORDERGRAAF A.: The use of computers for controlling the delivery of anesthesia. Anesthesiology, 77: 563-81, 199. 7- SIEBER T.J., FREI C.W., DERIGHETTI M., et al.: Model-

Magda S. Azer 77 based automatic feedback control versus human control of end-tidal isoflurane concentration using low-flow anesthesia. Br. J. Anaesth., 85: 818-5, 000. 8- BAUM J. and STANKE H.G.: Low-flow and minimalflow anesthesia with sevoflurane. Anaesthesist Nov., 47 Suppl 1: S70-6, 1998. 9- O BRIEN K., ROBINSON D.N. and MORTON N.S.: Induction and emergence in infants less than 60 weeks post-conceptual age: comparison of thiopental, halothane, sevoflurane and desflurane. Br. J. Anaesth., 80: 456-459, 1998. 10- SIGESTON P.E., JENKINS A.M.C., JAKSON E.A., SURY M.R.J., MACKERISE A.M. and HATGH D.J.: Rapid inhalation induction: 8% sevoflurane compared with 5% halothane. Br. J. Anaesth., 78: 36-65, 1997. 11- STRUYS M.M., KALMAR A.F., DE BAERDEMAEKER L.E., et al.: Time course of inhaled anaesthetic drug delivery using a new multifunctional closed-circuit anaesthesia ventilator. In vitro comparison with a classical anaesthesia machine. Br. J. Anaesth., 94: 306-317, 005. 1- SMITH I., TERHOEVE P.A., HENNART D., FEISS P., HARMER M., POURRIAT J.L., et al.: A multicentre comparison of the costs of anaesthesia with sevoflurane or propofol. Br. J. Anaesth., 83: 564-70, 1999.