Relax and Learn At the Farm 2012

Similar documents
Hemodynamic Monitoring and Circulatory Assist Devices

CATCH A WAVE.. INTRODUCTION NONINVASIVE HEMODYNAMIC MONITORING 4/12/2018

Technique. Technique. Technique. Monitoring 1. Local anesthetic? Aseptic technique Hyper-extend (if radial)

FUNDAMENTALS OF HEMODYNAMICS, VASOACTIVE DRUGS AND IABP IN THE FAILING HEART

Cath Lab Essentials: Basic Hemodynamics for the Cath Lab and ICU

Impedance Cardiography (ICG) Application of ICG in Intensive Care and Emergency

Hemodynamics: Cardiac and Vascular Jeff Davis, RRT, RCIS

Admission of patient CVICU and hemodynamic monitoring

DIAGNOSIS AND MANAGEMENT OF ACUTE HEART FAILURE

Topics to be Covered. Cardiac Measurements. Distribution of Blood Volume. Distribution of Pulmonary Ventilation & Blood Flow

Introduction. Invasive Hemodynamic Monitoring. Determinants of Cardiovascular Function. Cardiovascular System. Hemodynamic Monitoring

The right heart: the Cinderella of heart failure

Cardiovascular Practice Quiz

Critical Care Nursing Program August to November, 2015 Full-time Lesson A13 Pumping and Perfusion III Basic Hemodynamic Monitoring

Pulmonary Artery Catheter Helpful Hints 2017

HAEMODYNAMIC IN THE CATH LABORATORY INTRO TO BASICS

Pulmonary Artery Catheter Insertion (Assist) and Pressure Monitoring

Nothing to Disclose. Severe Pulmonary Hypertension

Rounds in the ICU. Eran Segal, MD Director General ICU Sheba Medical Center

PVDOMICS: Right Heart Catheterization Training

Cardiovascular Physiology. Heart Physiology. Introduction. The heart. Electrophysiology of the heart

Καθετηριασμός δεξιάς κοιλίας. Σ. Χατζημιλτιάδης Καθηγητής Καρδιολογίας ΑΠΘ

Unit 4 Problems of Cardiac Output and Tissue Perfusion

CARDIOGENIC SHOCK. Antonio Pesenti. Università degli Studi di Milano Bicocca Azienda Ospedaliera San Gerardo Monza (MI)

The Role of Mechanical Circulatory Support in Cardiogenic Shock: When to Utilize

Images have been removed from the PowerPoint slides in this handout due to copyright restrictions.

CARDIOVASCULAR MONITORING. Prof. Yasser Mostafa Kadah

Evolutionary origins of the right ventricle. S Magder Department of Critical Care, McGill University Health Centre

Intraaortic Balloon Counterpulsation- Supportive Data for a Role in Cardiogenic Shock ( Be Still My Friend )

BIOL 219 Spring Chapters 14&15 Cardiovascular System

Nitroglycerin and Heparin Drip Interfacility Protocols

Titrating Critical Care Medications

Capture every aspect of hemodynamic status

Cardiac Cycle MCQ. Professor of Cardiovascular Physiology. Cairo University 2007

IABP Timing & Fidelity. Pocket Reference Guide

Impedance Cardiography (ICG) Method, Technology and Validity

Complications of VAD therapy - RV failure

Understanding the Cardiopulmonary Bypass Machine and Its Tubing

Hemodynamic Monitoring

Cardiovascular Nursing Practice: A Comprehensive Resource Manual and Study Guide for Clinical Nurses 2 nd Edition

Disclosures. Objectives 10/11/17. Short Term Mechanical Circulatory Support for Advanced Cardiogenic Shock. I have no disclosures to report

LeMone & Burke Ch 30-32

Making the Case For Less Invasive Flow Based Parameters: APCO + SVV. Patricia A. Meehan, RN, MS, CCRN (a) Education Consultant Edwards Lifesciences

Effects of mechanical ventilation on organ function. Masterclass ICU nurses

Intra-Arterial Blood Pressure Monitoring

Pre-discussion questions

Aortic Dissection Causes of Death

Assessing Preload Responsiveness Using Arterial Pressure Based Technologies. Patricia A. Meehan, RN, MS Education Consultant Edwards Lifesciences, LLC

CHF and Pulmonary Edema. Rod Hetherington

Cardiovascular Management of Septic Shock

SHOCK Susanna Hilda Hutajulu, MD, PhD

Nurse Driven Fluid Optimization Using Dynamic Assessments

Calculations the Cardiac Cath Lab. Thank You to: Lynn Jones RN, RCIS, FSICP Jeff Davis RCIS, FSICP Wes Todd, RCIS CardioVillage.

Brief View of Calculation and Measurement of Cardiac Hemodynamics

Cardiopulmonary System

PROBLEM SET 2. Assigned: February 10, 2004 Due: February 19, 2004

IP: Regulation of Cardiac Output

Section 6 Intra Aortic Balloon Pump

Case Scenario 3: Shock and Sepsis

SHOCK. Emergency pediatric PICU division Pediatric Department Medical Faculty, University of Sumatera Utara H. Adam Malik Hospital

Hemodynamic monitoring beyond cardiac output

Medical Management of Acute Heart Failure

เอกราช อร ยะช ยพาณ ชย

Case year old female nursing home resident with a hx CAD, PUD, recent hip fracture Transferred to ED with decreased mental status BP in ED 80/50

Cardiovascular Physiology

Physiologic Based Management of Circulatory Shock Kuwait 2018

Medical Treatment for acute Decompensated Heart Failure. Vlasis Ninios Cardiologist St. Luke s s Hospital Thessaloniki 2011

Shock Quiz! By Clare Di Bona

Copyright 2011, 2007 by Mosby, Inc., an affiliate of Elsevier Inc. Normal Cardiac Anatomy

Percutaneous Mechanical Circulatory Support for Cardiogenic Shock. 24 th Annual San Diego Heart Failure Symposium Ryan R Reeves, MD FSCAI

Hemodynamic Changes in Obstetric Anesthesia. Sonia Vaida PANA, Hershey, April 2009

Patient Safety Safe Table Webcast: Sepsis (Part III and IV) December 17, 2014

A case of post myocardial infarction ventricular septal rupture CHRISTOFOROS KOBOROZOS, MD

Revision of 10/27/2017 Form #280 Page 1 of 12 PVDOMICS STUDY Clinical Center Right Heart Catheterization (RHC) Results Form #280

SUPPLEMENTAL MATERIAL

Goal-directed vs Flow-guidedresponsive

Management of acute decompensated heart failure and cardiogenic shock. Arintaya Phrommintikul Department of Medicine CMU

Management of Cardiogenic Shock. Dr Stephen Pettit, Consultant Cardiologist

A Diagnostic Dilemma saved by sound

How to do Primary Angioplasty. - Patients with Cardiogenic Shock

Right Heart Catheterization. Franz R. Eberli MD Chief of Cardiology Stadtspital Triemli, Zurich

Ventricular Assisting Devices in the Cathlab. Unrestricted

Cath Lab Essentials : LV Assist Devices for Hemodynamic Support (IABP, Impella, Tandem Heart, ECMO)

MASSACHUSETTS INSTITUTE OF TECHNOLOGY

Cardiac Output Monitoring - 6

DAY1_CARDIOVASCULAR PRACTICE QUESTIONS

Extra Corporeal Life Support for Acute Heart failure

Οξύ στεφανιαίο σύνδρομο και καρδιογενής καταπληξία. Επεμβατική προσέγγιση. Σωτήριος Πατσιλινάκος Κωνσταντοπούλειο Γ.Ν. Ν. Ιωνίας

Percutaneous Mechanical Circulatory Support Devices

Coronary Anomalies & Hemodynamic Identification

HISTORY. Question: How do you interpret the patient s history? CHIEF COMPLAINT: Dyspnea of two days duration. PRESENT ILLNESS: 45-year-old man.

Principles of Biomedical Systems & Devices. Lecture 8: Cardiovascular Dynamics Dr. Maria Tahamont

Cath Lab Essentials: Pericardial effusion & tamponade

Jeopardy Tip Sheets. 12 Lead EKG Review. Leads affected. Coronary artery involved. Area of myocardium INFERIOR RCA II, III, AVF SEPTAL LAD V1 & V2


Lab 16. The Cardiovascular System Heart and Blood Vessels. Laboratory Objectives

Ejection across stenotic aortic valve requires a systolic pressure gradient between the LV and aorta. This places a pressure load on the LV.

Acute Coronary Syndrome. Sonny Achtchi, DO

Swans and Pressors. Vanderbilt Surgery Summer School Ricky Shinall

Cardiogenic Shock. Carlos Cafri,, MD

Transcription:

Relax and Learn At the Farm Session 9: Invasive Hemodynamic Assessment and What to Do with the Data Carol Jacobson RN, MN Cardiovascular Nursing Education Associates Function of CV system is to deliver O to tissues Heart Arteries Veins Volume Hemodynamic monitoring evaluates the ability of CV system to deliver blood flow to tissues: Determinants of CO Blood volume Vascular tone Tissues job: extract and use O Lungs job: oxygenate blood Invasive Methods of Obtaining Hemodynamic Data Pulmonary Artery Catheter Cardiac output connection Distal (PA) tail Distal port Proximal (CVP) tail Proximal port Balloon port Pulmonary Artery Catheter CVP measures right atrial pressure and is used as a clinical indicator of RV preload -Normal CVP = -6 mmhg PWP reflects left atrial pressure and is used as a clinical indicator of LV preload -Normal PWP = 8- mmhg CVP PWP PA Catheter PVR is a calculated value based on mean PA pressure and PWP and is used as a clinical indicator of RV afterload - Normal PVR = < dynes SVR is a calculated value based on mean arterial pressure and CVP and is used as a clinical indicator of LV afterload - Normal SVR = 9- dynes SVR PVR In order for these calculated values to be accurate, the parameters they are based on need to be accurate: CVP & PWP Carol Jacobson RN, MN www.cardionursing.com

Hemodynamic Monitoring: Getting Accurate Data From a Pulmonary Artery Catheter Pressure Monitoring System Fluid System Fluid source: IV bag of cc of NS Caution: if patient has history of or suspected heparin induced thrombocytopenia (HIT) DO NOT use heparin in flush solution! A continuous fluid filled line from the IV bag to the transducer and from the transducer to the catheter tip is needed in order to monitor pressures. Pressure bag: IV bag must be pressurized at mmhg to overcome the resistance of the flush device in the transducer and to deliver ml per hour through the catheter to keep the line from clotting off. Tubing: high pressure rigid tubing is necessary to accurately transmit vascular pressures to the transducer. Transducer with flush device: contains a one-way valve that allows ml/hr of fluid to pass through unless the resistance is released by pulling the tail or pushing the lever on the device which allows the line to run wide open. PA Catheter Electrical System Transducer: contains fine wires that move back and forth with pressure changes and convert the pressure to an electrical signal that is sent to the monitor. Must be filled with fluid and be bubble-free to accurately transmit pressure. Connecting cable: connects the transducer to the bedside monitor and transmits the electrical signal to the monitor. Monitor: converts electrical signal to a waveform and displays it on the screen. AACN Practice Alert for Pulmonary Artery Pressure Monitoring - 9 Perform square waveform test each shift Position patient supine with HOB between º 6º, lateral, or prone (allow minutes to stabilize before reading pressures) Level stopcock air-fluid interface to phlebostatic axis Use graphic tracing that includes the ECG Take measurements at end expiration (or adjust if airway release ventilation or active expiration) Carol Jacobson RN, MN www.cardionursing.com

Square Waveform Test Fast Flush Determines ability of transducer to correctly reflect pressures in PA Identifies system problems Air bubbles Tubing too long Loose connections Loss of pressure on bag Catheter patency Square Waveform Test Perform the test Once each shift After opening system -Zeroing -Blood draws -Tubing changes Whenever PAP waveform appears damped or distorted Method of Performing Test Normal Square Waveform Test Verify mmhg pressure on bag Pull pigtail and release - watch response of system on monitor If abnormal Tighten connections Pump up bag Flush system Change transducer and tubing to patient if unable to correct Abnormal Fast Flush Tests Over damped Abnormal Fast Flush Tests Under damped Results in erroneously low SBP and high DBP Caused by: -Large air bubbles -Loose/open connections -Low fluid level in flush bag Results in erroneously high SBP and low DBP Caused by: -Small air bubbles -Tubing too long -Defective transducer Carol Jacobson RN, MN www.cardionursing.com

Marking the Phlebostatic Axis Phlebostatic axis is th intercostal space at mid anterior-posterior chest level (left atrial level) System needs to be zeroed and leveled at the phlebostatic axis Measure accurately and mark on chest Zeroing and Leveling Zeroing tells the monitoring system that atmospheric pressure is zero It removes the effect of hydrostatic pressure in the tubing system and establishes a baseline of zero so all pressure recorded by the system is patient pressure Leveling means that the stopcock that was used to zero must be at the phlebostatic axis for all pressure readings Keep the transducer at the phlebostatic axis while monitoring pressure To Zero the System Place the stopcock located on top of the transducer at the level of the phlebostatic axis Open the stopcock to air (turn it off to the patient) Push the Zero button on the monitor. This tells the transducer that atmospheric pressure is Zero and sets a baseline for pressure measurements. Close the stopcock to air (turn back to neutral position) This opens the line between the patient and the transducer and allows the transducer to see the patients pressure Leveling Stopcock used to zero must remain at phlebostatic level regardless of patient position. Leveling must occur with every reading For every cm deviation from true phlebostatic axis, pressures can change.86 mmhg Obtain measurements from graphic tracing that includes the ECG Read at end expiration Carol Jacobson RN, MN www.cardionursing.com

Right Atrial Waveforms Normal CVP -6 mmhg a wave = atrial contraction and follows P wave c wave = closure of tricuspid valve v wave = atrial filling and follows QRS a v ac v Record the mean of the a wave for the CVP CVP Swan Insertion RA to RV a v RA RV Identify a and v waves What is the CVP measurement? Right Ventricular Waveforms The monitor is never right on the RV diastolic pressure! It reads the lowest point We want to record the plateau (true RVEDP) Normal RV Waveform Identify RV systolic and diastolic pressure. - -6 - - - - Systolic Diastolic RV Pressure = 8/ Carol Jacobson RN, MN www.cardionursing.com

RV Pressure Swan Insertion RV to PA Identify RV Systolic and Diastolic Pressure - - - - RV PA RV Pressure = /7 Pulmonary Artery Waveforms PA Waveform - 8- The monitor is usually right about PA pressures No false lows Ignore the pre-systolic bump Sy stolic Identify PA Systolic and Diastolic pressure What is the pressure? PAP = / Diastolic Swan Insertion PA to PWP Wedge Pressure Waveform 8- mmhg Same a, c, and v waves as CVP Further removed from the ECG waves a wave near end of QRS v wave after T wave PA PWP Record the mean of the a wave for the PWP a v Carol Jacobson RN, MN www.cardionursing.com 6

PWP Waveform Normal PAW Identify a and v waves and state the value of the PWP - a - - PWP = 6 mmhg v - a v - - Identify a and v waves and state the PWP measurement PAW = mmhg Large v Waves in PAW Waveform v a c Identify two problems this patient has. LV failure: elevated PAWP (mean of a wave) Mitral regurgitation: large v wave End Expiration in Spontaneous Breathing Spontaneous Breathing Inspiration is a negative dip in waveform. Find end-expiration. Where would you read the PA and the PAW pressure? Carol Jacobson RN, MN www.cardionursing.com 7

PA to PAW Spontaneous Breathing End Expiration in Ventilator Breath Inspiration is a rise the in waveform a v PA pressure = 8/ PAW pressure = Ventilator Breaths a v a v Find the ventilator breath. Where would you read this PAW pressure? PWP = 6 Goals of Hemodynamic Monitoring Determine magnitude of pulmonary congestion (LV preload) Assess peripheral perfusion (forwards flow) Determine LV function based on preload and forwards flow CI/SV, skin temp (warm or cold) Left Ventricular Function Curves 6 8 6 8 6 8 6 Carol Jacobson RN, MN www.cardionursing.com 8

Changing Preload: moves patient along the curve they are on. Changing Contractility: moves patient to a higher curve CI/SV, skin temp (warm or cold) 6 8 6 8 6 8 6 CI/SV, skin temp (warm or cold) 6 8 6 8 6 8 6 CI/SV, skin temp (warm or cold) Changing Afterload: moves patient up and to the left (improves forwards flow and reduces preload) 6 8 6 8 6 8 6 Relationship of PWP to Clinical Signs of Pulmonary Congestion PWP 8 mmhg mmhg mmhg > mmhg Clinical State Pulmonary Congestion Moderate Congestion Severe Congestion Pulmonary Edema The value for PWP that best separates patients with and without pulmonary congestion is 8 mmhg Physical assessment: lung sounds dry or wet. Relationship of CI to Clinical Signs of Hypoperfusion CI.7.7..7.8. <.8 Clinical State Normal Subclinical depression Clinical hypoperfusion Cardiogenic shock The value for CI that best separates patients with and without hypoperfusion is. L/min/M Physical assessment: skin temperature warm or cold CI/SV, skin temp (warm or cold) Hemodynamic and Clinical Subsets Normal Hemodynamics (I) No pulmonary congestion: PWP < 8; Dry lungs No hypoperfusion: CI >.; Warm skin Warm & Dry Forwards Failure (III) No pulmonary congestion PWP < 8; Dry lungs Hypoperfusion CI <.; Cold skin Cold & Dry Backwards Failure (II) Pulmonary congestion PWP > 8; Wet lungs No hypoperfusion CI >.; Warm skin Warm & Wet The Shock Box (IV) Pulmonary congestion PWP > 8; Wet lungs Hypoperfusion CI <.; Cold skin Cold & Wet 6 8 6 8 6 8 6 Carol Jacobson RN, MN www.cardionursing.com 9

Mini Case # A patient returns to the ICU after a AAA repair with a PA catheter in place. This is the first set of data: HR = 96, BP = /7, CO =., CI =., CVP =, PWP = 8, SVR = 8. 6 8 6 8 6 8 6 Mini Case # A patient with acute anterior MI returns from the cath lab with a PA catheter in place following two stents to the LAD coronary artery. The first set of numbers looks like this: BP /6, HR = 6, CO =., CI =.8, CVP =, PWP =, SVR = 68. 6 8 6 8 6 8 6 Mini Case # A year old motor cycle accident victim with multiple trauma is on the ventilator in the ICU and becomes hypotensive and febrile. His BP is 8/, HR in sinus tachycardia, skin is hot and dry. A PA catheter is inserted and these are the numbers: CO =., CI =, CVP =, PWP =, SVR =. 6 8 6 8 6 8 6 Mini Case # A 6 year old woman with a history of HF returns from CABG with the following data: BP 6/76, HR = 8, CO =., CI =., CVP = 8, PWP = 6, SVR = 8. 6 8 6 8 6 8 6 Preload changes: move patient along the current curve 6 8 6 8 6 8 6 Carol Jacobson RN, MN www.cardionursing.com

Afterload changes: move patient up and to the left: improves forwards flow and reduces preload 6 8 6 8 6 8 6 Must have adequate BP SVR must be elevated Contractility changes: move patient to a higher curve 6 8 6 8 6 8 6 Summary of the Effects of Therapies D V + I V 6 8 6 8 6 8 6 D = Diuresis (preload reduction) F = Fluids (increase preload) I = Inotropes (increase contractility) V = Vasodilators ( reduce afterload) V + I = Vasodilator + Inotrope I F Forwards Flow: Cardiac Index Skin temp (warm or cold) Potential Therapies by Subset Normal Hemodynamics In sepsis or trauma:? Inotropes Forwards Failure Volume (if PWP low ) Inotropes (if PWP adequate) Pacing (if HR low ) IABP 6 8 6 8 6 8 6 Backwards Failure Diuretics Venous Dilators Shock Box Afterload reduction (if BP adequate and SVR high) Preload reduction (diuretics, venous dilators) Inotropes, Vasopressors, IABP Mini Case # A patient with acute anterior MI returns from the cath lab with a PA catheter in place following two stents to the LAD coronary artery. The first set of numbers looks like this: BP /6, HR = 6, CO =., CI =.8, CVP =, PWP =, SVR = 68. 6 8 6 8 6 8 6 Mini Case # Where would he go with preload reduction? Where would he go with an inotrope? What drugs could you use? Where do you want him to go? Where should he go with afterload reduction? Is he a candidate for afterload reduction? Yes: BP is reasonable and SVR is high 6 8 6 8 6 8 6 Carol Jacobson RN, MN www.cardionursing.com

More than one way to accomplish a goal Hemodynamic Profiles in Shock Preload (PWP) Afterload (SVR) Pump Function (CI/SV) Tissue Perfusion (SVO ) Therapy Diuretic Inotrope 6 8 6 8 6 8 6 Hypovolemic (Subset III) Cardiogenic (Subset IV) Vasodilated (Subset I early) (Subset IV late) Volume Inotropes Preload reduction Afterload reduction Volume Vasopressors Carol Jacobson RN, MN www.cardionursing.com