Posner s Attention Test

Similar documents
The Gaze Cueing Paradigm with Eye Tracking Background Set-up Lab

Experiment HP-28: Control of EEG and Biofeedback Lab/Research Study

Red Light - Green Light

Experiment HP-13: The Gaze Cue Paradigm

Experiment HM-11: Electromyograms (EMG) for Paired Arm Wrestling

iworx Sample Lab Experiment HP-7: Hypothesis-driven Biofeedback Lab/Research Study

Lab 5: Electromyograms (EMGs)

Experiment HE-12: Targeted Exercise with Wireless Electrocardiogram (ECG)

Exercise 1: Eye-Hand Reaction Times Aim: To measure the reaction time of a subject to a visual cue when responding with the hand.

Experiment HH-3: Exercise, the Electrocardiogram, and Peripheral Circulation

BP-600 Noninvasive Blood Pressure Sensor

Experiment HH-3: Exercise, the Electrocardiogram, and Peripheral Circulation

Figure HN-5-L1: The Sequence menu containing the preprogramming light sequences used in this experiment.

iworx Sample Lab Experiment HH-4: The Six-Lead Electrocardiogram

FT-302 Force Transducer

iworx Sample Lab Experiment HC-3: Pulse Wave Velocity

Experiment HM-7: Electromyogram (EMG) Activity in Antagonistic Muscles and Range of Motion

Experiment HH-2: The Electrocardiogram and Heart Sounds

iworx Sample Lab Experiment AN-5: Cockroach Leg Mechanoreceptors

Metabolic and Thermal Response to Exercise

Kinesiology and Electromyogram (EMG) Activity in Targeted Muscles

Exercise 2: Effects of Cold Temperature Aim: To record changes in heart rate after the heart is bathed in cold Ringer s solution.

BLINDED MODE USERS GUIDE SUPPLEMENT

iworx Sample Lab Experiment HH-4: The Six-Lead Electrocardiogram

Kidney Dialysis and Conductivity Background Set-up Lab Appendix

Laerdal-SonoSim Procedure Trainer

Exercise 6: Muscle Physiology II Twitch & Summation

Overview. Page 1 of 9. Impedance Cardiography

Lesson 1 ELECTROMYOGRAPHY I Standard and Integrated EMG

Biology 13A Lab #10: Cardiovascular System II ECG & Heart Disease

Cardiovascular Effects of Exercise. Background Cardiac function

Lesson 2 EMG 2 Electromyography: Mechanical Work

Warning: Avoid putting the tip of the syringe needle too deeply into the hole to avoid damage to the heart tissue.

BSL PRO Lesson H03: Nerve Conduction Velocity: Along the Ulnar Nerve of a Human Subject

User Manual. RaySafe i2 dose viewer

Sleep Apnea Therapy Software User Manual

RELEASED. Clearing your active insulin

iworx Sample Lab Experiment HP-6: Cynicism/Hostility and the Hot Reactor

Introductory Motor Learning and Development Lab

Sleep Apnea Therapy Software Clinician Manual

Grouped Locations and Object-Based Attention: Comment on Egly, Driver, and Rafal (1994)

Exercise 5: Muscle Physiology I - Electromyography

Heart Rate and Body Position

Appendix B. Nodulus Observer XT Instructional Guide. 1. Setting up your project p. 2. a. Observation p. 2. b. Subjects, behaviors and coding p.

1724 Lab: Frog Skeletal Muscle Physiology (Marieb Exercise 16A) Marieb/iWorx / Ziser, 2002

iworx Sample Lab Experiment HP-1: The Galvanic Skin Response (GSR) and Emotion

Desktop Fitting Guide for Phonak Brio 3

Lab 7. Physiology of Electrocardiography

Ava Fertility Tracker User Manual Version 2.0. Not for contraceptive use.

Actiwatch. Clinician Guide

Owner s Booklet. Wirelessly sends accurate glucose results to MiniMed Paradigm and Guardian Devices. Blood Glucose Monitoring System

Ava Fertility Tracker User Manual Version 5.0. Not for contraceptive use.

iworx Sample Lab Experiment AN-1: Membrane Potentials

Sanako Lab 100 STS USER GUIDE

iworx Sample Lab Experiment HC-5: Body Position, Exercise, and Cardiac Output

RaySafe i3 INSTALLATION & SERVICE MANUAL

Experiment HP-4: The Galvanic Skin Response (GSR) and Investigation into Cheating

Introduction to Computational Neuroscience

Functional Fixedness: The Functional Significance of Delayed Disengagement Based on Attention Set

Cardiovascular Physiology

MedRx Video Otoscope Software

QUICK START GUIDE TYMPANOMETRY AND AUDIOMETRY FOR SENTIERO DESKTOP DEVICES

Lesson 1: Types of ECG s

Demo Mode. Once you have taken the time to navigate your RPM 2 app in "Demo mode" you should be ready to pair, connect, and try your inserts.

ELECTROMYOGRAM ANALYSIS OF MUSCLE FUNCTION INTRODUCTION

LABORATORY INVESTIGATION

Posture Monitor. User Manual. Includes setup, guidelines and troubleshooting information for your Posture Monitor App

Module 4: Effect of Alcohol on Worms

Lesson 2 ELECTROMYOGRAPHY II Motor unit recruitment Fatigue

The following describes general use of ELIOS device

Phonak Target 4.3. Desktop Fitting Guide. Content. March 2016

ChildFit. Widex Baby. Compass quick guide

AudioConsole. User Guide. Doc. No EN/01 Part No EN

Fitting System Instructions for Use

OneTouch Reveal Web Application. User Manual for Patients Instructions for Use

2.0. Desktop Fitting Guide getting started. Preparation of the hearing instruments

Dosimeter Setting Device

Software Version 2.0. User s Guide

GETTING STARTED WITH MINIMED 670G CONTINUOUS GLUCOSE MONITORING

Step-by-Step RECD Guide

Ava Fertility Tracker User Manual Version 4.0. Not for contraceptive use.

Department of Computer Science, University College London, London WC1E 6BT, UK;

Lesson 4 ECG 2 Electrocardiography

Data Management System (DMS) User Guide

Physiology Lessons for use with the Biopac Student Lab. Lesson 1 ELECTROMYOGRAPHY I Standard and Integrated EMG

BlueBayCT - Warfarin User Guide

Titronics Range of Motion Hardware & Software Installation

Biopac Student Lab Lesson 6 ELECTROCARDIOGRAPHY (ECG) II Analysis Procedure. Rev

Lab 4: Introduction to Physiological Measurements - Cardiovascular

GETTING STARTED. Continuous Glucose Monitoring MiniMed 630G System

CMS-50E Instructions by Cooper Medical Supplies (These instructions are to supplement the manufacturer s user manual not to replace it!

Quick guide for 3shape order form

Living with Newton's Laws

QUICK START GUIDE SENTIERO OAE, TYMP AND AUDIOMETRY SCREENING ( and )

Beltone Solus Pro 1.9 Fitting Guide

The path of visual attention

Bio-logic AuDX PRO FLEX Screening tympanometry and audiometry Quick start guide

Transcription:

iworx Physiology Lab Experiment Experiment HP-18 Posner s Attention Test Background Setup Lab Note: The lab presented here is intended for evaluation purposes only. iworx users should refer to the User Area on www.iworx.com for the most current versions of labs and LabScribe Software. iworx Systems, Inc. www.iworx.com iworx Systems, Inc. 62 Littleworth Road, Dover, New Hampshire 03820 (T) 800-234-1757 / 603-742-2492 (F) 603-742-2455 LabScribe is a trademark of iworx Systems, Inc. 2017 iworx Systems, Inc.

Experiment HP-18: Posner s Attention Test The Posner Cueing Task, also known as the Posner paradigm, is a psychological test used to assess attention and attention deficit. This task, formulated by Michael Posner, attempts to assess an individual s ability to perform an attentional shift. Attentional shift occurs when attention is directed to a focal point to increase the efficiency of processing and includes inhibition to decrease attention towards unwanted or irrelevant input. Posner's spatial cueing task is a timing task used to measure manual and/or eye-movement reaction to target stimuli in order to determine the effects of covert orienting of attention in response to different cue conditions. Subjects sit in front of a computer screen situated at eye level. They are instructed to look at a central point on the screen, marked by a cross. To the left and the right of the cross are 3 boxes. For a brief period, a brightened stimulus is presented on the screen; this is followed by a target stimulus, usually a shape, that appears in either the same location as the stimulus or in another box. The observer must respond to the target stimulus immediately after detecting it. Only the correct response counts. Two major cue types can be used to analyze attention based on the type of visual input. An endogenous cue is presented in the center of the screen, usually at the same location as the center of focus. It is usually an arrow pointing to the left or right boxes on the screen. This cue relies on input from the central visual field. An exogenous cue is presented outside of the central focal point, usually a brightening of the left or right boxes presented. An exogenous cue can also be an object or image in the periphery, a number of degrees away from the center, but still within the visual field. This cue relies on visual input from your peripheral vision. This particular version of Posner s experiment relies on the use of these exogenous cues. Dr. Posner devised a method of using valid and invalid cues for the trials. Valid trials have the stimulus is presented in the same area as the cue. For example, if the cue was a brightening of the first box to the left of center, then the target will also be the first box to the left of center. Invalid trials have the stimulus presented on the side opposite the cue. In this case, the cue would be on the right but the stimulus on the left. Posner used a ratio of 80% valid trials and 20% invalid trials in his original studies. Eye movements can also be tracked using an electroculogram or an eye-tracking system. By adding this additional recording, we can differentiate between overt and covert attention. Overt attention involves directed eye movements, known as saccades, to consciously focus the eye on a target stimulus. Covert attention involves mental focus and attention to an object without any significant eye movement, and is the predominant area of interest when using the Posner cueing task for research. Using the same 80% valid and 20% invalid parameters, Posner tried to encourage covert shifts of attention to take place in response to cueing. When we attend to a location, even without directly looking at it, it facilitates processing and decreases the time we need to respond to information occurring in that given space. This results in decreased reaction times in Posner's spatial cueing task for validly cued targets, and slower reaction times in response to invalidly cued targets. Human Psychophysiology Attention Background HP-18-1

Experiment HP-18: Posner Attention Test Equipment Required PC or Mac Computer IXTA, USB cable, power supply EM-220 Event Marker iwire-b3g and 3 electrodes for EOG Optional itrax Eye-Tracking System Start the Software 1. Click on LabScribe 2. Click Settings Human Psychophysiology PosnerAttentionTest 3. Once the settings file has been loaded, click the Experiment button on the toolbar to open any of the following documents: Appendix Background Labs Setup (opens automatically) Sensor Setup 1. Locate the EM-220 Event Marker and plug it into the EM1 input on the back of the IXTA (Figure HP-18-S1). 2. Plug the iwire-b3g into the iwire 1 port on the front of the IXTA and attach the red, black and green leads (Figure HP-18-S2). NOTE Plug the iwire-b3g into the IX-TA before turning the unit on. Figure HP-17-S1: EM-220 Event Marker. HP-18-1

Figure HP-18-S2: iwire-b3g. You will use the red, black and green electrodes. Figure HP-17-S3: The IX-TA shown with both the EM-220 and iwire-b3g attached. For the Subject: 1. Use an alcohol swab to clean and scrub the areas where the electrodes will be placed (Figure HM-3-S3). Let the areas dry before attaching the electrodes. 2. Trim the electrodes and then remove the plastic disk. Snap the leads onto the electrodes before applying them to the subject s head. 3. Snap the recording lead wires onto the electrodes, so that: 1. the red (+1) lead is on electrode next to the left eye. 2. the black (-1) lead is on electrode next to the right eye. 3. the green (C) lead (the ground) is on electrode below the right ear. HP-18-2

4. Place the electrodes to each of the other areas. Figure HM-18-S4: Placement of electrodes for recording an electroculogram (EOG). 5. Have the subject hold the event marker in his or her dominant hand. 6. When the subject is ready, click the Record button and click the Instructions sequence to learn what needs to be done for this experiment. Measure the distance from the screen the subject needs to be sitting. Make sure the subject understands to ONLY click the event marker when the cue and the target are the same box. OPTIONAL - Eye Tracker Setup You must chose the itrax View from the View menu on the LabScribe toolbar. 1. Open External Devices on the main menu bar (Figure HP-18-S5). Figure HP-18-S5: External Devices set up window. HP-18-3

2. Enter the license information provided and set up the parameters for eye tracking (Figure HP- 18-S6) and open the Setup: Gaze Duration (msec): The amount of time, in msec, before the current time that fixation information will be displayed in the Eye Tracking window. Outlier Filter (msec): The amount of time, in msec, that the eye has to be fixated at a single spot. If the fixation duration is less than the Outlier Filter value, then the fixation will not be displayed in the Eye Tracking window. Time Offset (msec): This can be used to take care of any time offset between the eye tracking data and LabScribe data. Display Scaling (%): The Eye Tracker tracks the complete screen. We want to analyze LabScribe data as well as eye tracking data. Display scaling allows for the eye tracking window to show a scaled version of the screen. Fixation Size: The fixation data is shown as a circle whose radius is proportional to the fixation duration. The circle size is the radius of the circle in pixels corresponding to a 1 second fixation duration. Figure HP-18-S6: Eye tracking set up dialog window. 3. Set up the Area of Interest (AOI) if there is a specific location on the image you wish the subject to focus on. Note that some experiments will just want to see where the subject is focusing rather than knowing when the subject focuses on the designated area. HP-18-4

Choose AOI#, click the drop down to have the AOI shown as a circle or rectangle Open the image that the subjects will be looking at in an image editing program such as Paint, Photoshop, Lightroom Hover over the AOI, note the X and Y pixel coordinates and enter these in the boxes to the right of AOI# When you choose to Show the EyeTracking Window - the image the subject is looking at will be shown on one monitor with the AOI in blue. The actual image the subject will be looking at on the second monitor will not show the AOI. NOTE: If you want to know when the subject looks at a specific location, you must set the AOI. 4. To acquire eye tracking data, the GazePoint module has to be enabled in LabScribe and the GazePoint application has to be running. 5. Calibrate the GazePoint Eye Tracking sensor (Figure HP-18-S7). Figure HP-18-S7: Eye tracking calibration window. 5. Choose the screen that the subject will be using. Then calibrate the Eye Tracker. 6. Refer to the GazePoint manual for more instructions to calibrate the system. 7. The image window in LabScribe should be moved over to a second monitor if using multiple monitors. Note that 2 monitors is preferable in this experiment especially when looking at AOI data. 8. Enable the Eye Tracking window by choosing External Devices GazePoint Eye Tracker Show Eye Tracking Window (Figure HP-18-S8). HP-18-5

Figure HP-18-S8: Eye tracking window and GazePoint Eye Tracker. HP-18-6

Experiment HP-18: Posner Attention Test General Directions: Subjects will be shown a series of 150 cues and 150 targets. Each cue will have a fixed center cross (for vision fixation) with 3 square boxes on each side. One of the boxes will be white, the other 5 will be gray. The cue will be shown for 150 msec. Once the cue is shown, a target will appear. It will appear 100 to 600 msec after the cue. The target will have the same center fixation cross and square boxes. One of the square boxes will have a target star in it, the other boxes will be gray. The target will be shown for 150 msec. The subject will click the event marker ONLY if the target star shows up in the SAME box as the white cue. Procedure Warning: It is important to press the event marker immediately upon recognizing if the target and cue match. 1. Click on the Record button. 2. Click the Instructions sequence on the toolbar and run the sequence. Follow the instructions to situate your subject at the proper distance from the computer screen. 3. Click Stop once you have followed the measurement procedure. 4. When ready to start the experiment, click the Record button. 5. Choose the Attention sequence on the toolbar and run the sequence. 6. Follow the general directions as outlined above. 7. After the last cue and target have been shown, click Stop to halt recording. 8. Click on the Save button to save the data file. Human Psychophysiology Attention Labs HP-18-1

Figure HP-18-L1: Sample of what the data may look like. This sample only shows one graph of data. For this experiment, there will be two graphs of data, one representing the Reaction and one for the EOG. Note if using the I-TRAX, there will be 3 graphs: Reaction, AOI and Velocity. Data Analysis Figure HP-18-L2: LabScribe toolbar. REACTION TIME: 1. Click the Double Display time button until approximately 10 responses show on the screen. 2. Move one red cursor line to the mark made when the TARGET was shown and the 2 nd to the start of the click of the event marker or response pad. Make a notation if the Target shown actually matched the cue shown previous to it. 3. Look at T2-T1 (upper right corner) and record that number. 4. Repeat for the next 9 responses. Human Psychophysiology Attention Labs HP-18-2

5. Repeat the procedure for the next set of 10 targets, keep repeating for a total of 150. 6. Enter the data into a table. EOG: 1. Move back to the data where the Attention sequence began. 2. Look at the EOG channel to see where saccadic eye movement has occurred. 3. Place the cursors on either side of the time the cue was presented to when the subject reacted. Look at the EOG signal. Measure the Mean value for EOG during this time period. 4. Repeat the EOG measurements for 20 correct responses, and calculate the average EOG. 5. Repeat step 4 for 20 non-responses by placing the cursors at the start of the cue and 150 msec after the target. Calculate the average EOG. Questions: 1. What was the mean reaction time of the subject? 2. What was the total percentage correct? 3. What was the average EOG when the subject answered correctly? When there were nonresponses? 4. Is there a different in average EOG? Why? 5. Explain the Posner Attention Paradigm. Human Psychophysiology Attention Labs HP-18-3