Universal Bussed Gutters, Amp Bussed Gutters for TB/MTB Units, Amp Termination Enclosures, Amp...

Similar documents
Meter Equipment Group

JEFFERSON Cabinet Style Transformers Three-Phase 15 to 1000 KVA

HPS MILLENNIUM GENERAL PURPOSE MEDIUM VOLTAGE Distribution

Standards. n Built in accordance with NEMA, ANSI, UL and CSA standards

SECTION B ELECTRICAL/MECHANICAL LUGS & NEUTRAL BARS

STAINLESS STEEL CABINET HARDWARE & DOOR PULLS

Easy assembly with standard tools. Fully insulated for direct mounting to steel panels

SWITCHGEAR PBD. fuse bases

SWITCHGEAR PBD. fuse bases

SED2 VFD NEMA Type 3R Bypass, and Type 3R Harsh Environment (3RHE) Bypass

Description. Specifications and Ordering Information Proximitor Sensor / interface module/ VDC Housings

Areamaster 250/400 Integrally Ballasted Floodlights 100 W to 400 W HID For hazardous and marine locations.

Applications. Projected Area: 1.9 Sq. Ft. Dimensions in Inches/Millimeters

Fittings & Accessories

Features CONSTANT WATTAGE AUTOTRANSFORMER 1.9 SQ FT Lamp Included 0 MOGUL BASE HIGH PRESSURE SODIUM

Roton Continuous Hinges

VARITRANS Technical Details Glass Partition Systems Compactline, Metalline

Bronze Parallel, Cross, and Bar Taps TYPE DGF, DGG. Ordering Information. or Copper Grounding Connector

STAINLESS STEEL CABINET HARDWARE & DOOR PULLS

Product reference. LV switch-disconnectors 3. Product panorama 9. Functions and characteristics 17. Installation and connection 47

,846 pounds of coal burned. 403 gallons of gasoline consumed. additional acres of forest in one year. tons of waste sent to the landfill

,846 pounds of coal burned. additional acres of forest in one year. tons of waste sent to the landfill. gallons of gasoline consumed

Fuse Combination Switches & Switch Disconnectors Dimensions

NEMA FRAME DIMENSIONS* FOOT-MOUNTED AC MACHINES

Datasheet BR Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors

MOTOR STARTING AUTOTRANSFORMERS

EPIC CONNECTORS. STA Series

SE Optimus Combination Shower and Eye And Face Wash System EYEWASH FEATURES: SHOWER FEATURES FINISH: OPTIONS: WARRANTY:

QUALITY WEATHERPROOF ELECTRICAL EQUIPMENT

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

R-Group Finland Oy. RLS Lifting Sockets Technical Manual According to Eurocodes, EU Machinery directive 2006/42/EC and VDI/BV-BS 6205 CE Approved

HAUSMANN SPACE PLANNING GUIDE A helpful guide to make the most of your space

ENERGY EFFICIENT DISTRIBUTION TRANSFORMERS

1 Exam Prep. SMACNA Architectural Sheet Metal Questions

ST SIGN TYPES - CURBSIDE 3.0 SIGN TYPES - TERMINALS. Terminals Sign Types - Layout 3.5. Floor mount. Informational-Primary/Secondary 3.5.

MS MS Manual Motor Starter. General Information. Ordering. Popular Downloads. Dimensions MS Extended Product Type

ENERGY EFFICIENT DISTRIBUTION TRANSFORMERS

TEKNOCRAFT INC. Proportional Valves. Mini Valves. Outlet Balanced Valves. Standard Valves. Your Proportional Valve Specialists

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

Typ 1 19" electronic cabinet without front and rear door Features

MS MS Manual Motor Starter. General Information. Ordering. Popular Downloads. Dimensions MS Extended Product Type

S201-Z2. Miniature Circuit Breaker - S200-1P - Z - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions.

Lift Accessories. For Hunter Wheel Alignment Lift Racks. Includes Inflation Stati and Fully Inte Alignment Features

CADWELD TO THERMOWELD CROSS REFERENCE FOR CATHODIC PROTECTION

Miniature Circuit Breaker - S200-1P - B - 2 ampere. acc. to IEC / 400 V AC acc. to IEC V AC

ADAPTER IECEx-ATEX, RNC, IP66 / 68, NICKEL PLATED BRASS

P SERIES. 250 psi NFPA Pneumatic Cylinder TECHNICAL BROCHURE. Bore Sizes from 11/2 to 14

S201-C2. Miniature Circuit Breaker - S200-1P - C - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions.

Accessories for LV AirGuard Cables Glands, Connectors and Installation Tools.

AIR COOLED CONDENSERS

Al and AlCu terminals and connectors mm²

Great food served on the world s best pans

CP-PP PANS ROLLED EDGE DISK PERF DISK ELEVATED PERF DISK FLAT BREAD DEEP DISH ROLLED EDGE DEEP DISH STRAIGHT EDGE GRILL PANS PANINI PANS SHEET PANS

Varitrans. Technical Details Glass Partition Systems Compactline Metalline

2011/2012 Cabinet Handle Range. Cabinet Handle Range

service Quality Delivery NorgrenExpress.com EXPrEss PLUS M/50 switches Mounts c/ Ø 25 to 63 mm ACT-31

General Information. Ordering. Popular Downloads. Dimensions. Technical

Flume Installation Instructions

CFT Series CABINET FAN

Needle Valves Catalog 4110-NV December 2010

Restoring Straumann implants. with Locator abutments.

S202M-K2UC. Miniature Circuit Breaker - S200MUC - 2P - K - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions.

Access controlled Future secured. VEHICLE SECURITY BARRIERS PORTFOLIO

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

CFT Series CABINET FAN

Select. GT 500 DZ Premium PM Cobalt FIREX Coated Drills. NEW for Premium quality, competitively priced high-performance cutting tools

Mechanically actuated valves

Polyester distribution boxes

RELAX.REVITALIZE.RESTORE.

ELITE RANGE Oak Tiepolo Walnut

PRODUCT CATALOG. Since 1985» Simple. Predictable. Profitable.

General Information. Ordering. Popular Downloads. Dimensions. Products Low Voltage Products and Systems Circuit Breakers Manual Motor Starters

CFT Series CABINET FAN

ENERGY EFFICIENT GENERAL PURPOSE DISTRIBUTION TRANSFORMERS

JNL454 55" STOP. 40kg 88lbs. 140cm. AVF Group Ltd. Hortonwood 30, Telford, Shropshire, TF1 7YE, England. Leaflet No rev00

RiGO801 Laboratory Requirements

20 Kinesiotherapy. Types of base system:

Chapter 7. Communication Elements and Features

Base S D T B

1 mm 2 mm 3 mm 4 mm 5 mm 6 mm

RJA RJA. Welded cabinet with demountable side panels and back panel, IP 20, loading capacity 600 kg

PERFORMANCE CRITERIA FOR ACCESSIBLE COMMUNICATIONS ENTRY SYSTEMS

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: US ALUMINUM INC., DIVISION OF CR LAURENCE CO., INC.

BALANCE. n: a state of bodily equilibrium \bal-uh-ns\ v: to bring to or hold in equilibrium

aks bed concepts for the day-to-day nursing routine for homecare and in-patient applications

Series SY3000/5000/7000 Manifold Options

kythe Premium Pump LKH Centrifugal Pump

HPS Centurion R Iron Core Reactors

Technical Data Sheet SONOFLOW CO.55 V1.0

type AKS and ESM Introduction

DHS Plate 135º. DHS Platte 135º

PLANNING GUIDE BUILT-IN OVENS, MICROWAVES & WARMING DRAWERS

DURASEAL. High Integrity, Double Block and Bleed Plug Valve.

Model Number System Double Reduction Helical-Worm

Universal Power Procedures Table

Perform ten 30 second intervals alternating 5 at a slow speed with 5 at a moderate speed.

The Premium Choice in Landscape Lighting

THE GREAT EIGHT. Australian Institute of Fitness 1 / 13

Ravenna Collection. Specification Sheets for Ravenna Vanities & Linen. Specifications: SPECIFICATION VARIANCES

Transcription:

Universal Bussed Gutters, 400-2000 Amp........................................... 49-50 Bussed Gutters for TB/MTB Units, 400-800 Amp................................... 51-52 Termination Enclosures, 100-1200 Amp............................................. 53-54 48

Universal Bussed Gutters 400-2000 Amp R1060HEE (closed) R1060HEE (open) Application With KOs for ganging TB/MTB units under a common feed Surface mount Construction NEMA Type 3R ANSI 61 gray E-coat finish Aluminum bussing Standards UL 1773 Listed Part/UPC Catalog Buss Service Connections Overall Dimensions Knockout Number Number Amps Type AIC Line Load Neutral Height Width Depth Layout 78205118055 R1024 HC 400 1Ø/3W 10K #4-600 MCM See Note * #4-600 MCM 22 24 6 Fig. 1 78205118065 R1036 HC 400 1Ø/3W 10K #4-600 MCM See Note * #4-600 MCM 22 36 6 Fig. 1 78205118075 R1048 HC 400 1Ø/3W 10K #4-600 MCM See Note * #4-600 MCM 22 48 6 Fig. 1 78205118085 R1060 HC 400 1Ø/3W 10K #4-600 MCM See Note * #4-600 MCM 22 60 6 Fig. 1 78205118095 R1072 HC 400 1Ø/3W 10K #4-600 MCM See Note * #4-600 MCM 22 72 6 Fig. 1 78205118115 R1036 HD 600 1Ø/3W 10K (2) #4-600 MCM See Note * (2) #4-600 MCM 22 36 6 Fig. 1 78205118125 R1048 HD 600 1Ø/3W 10K (2) #4-600 MCM See Note * (2) #4-600 MCM 22 48 6 Fig. 1 78205118135 R1060 HD 600 1Ø/3W 10K (2) #4-600 MCM See Note * (2) #4-600 MCM 22 60 6 Fig. 1 78205118145 R1072 HD 600 1Ø/3W 10K (2) #4-600 MCM See Note * (2) #4-600 MCM 22 72 6 Fig. 1 78205118325 R1048 HE 800 1Ø/3W 10K (3) #4-600 MCM See Note * (3) #4-600 MCM 22 48 6 Fig. 1 78205118335 R1060 HE 800 1Ø/3W 10K (3) #4-600 MCM See Note * (3) #4-600 MCM 22 60 6 Fig. 1 78205118345 R1072 HE 800 1Ø/3W 10K (3) #4-600 MCM See Note * (3) #4-600 MCM 22 72 6 Fig. 1 78205118215 R1024 HCC 400 3Ø/4W 10K #4-600 MCM See Note * #4-600 MCM 22 24 6 Fig. 1 78205118225 R1036 HCC 400 3Ø/4W 10K #4-600 MCM See Note * #4-600 MCM 22 36 6 Fig. 1 78205118235 R1048 HCC 400 3Ø/4W 10K #4-600 MCM See Note * #4-600 MCM 22 48 6 Fig. 1 78205118245 R1060 HCC 400 3Ø/4W 10K #4-600 MCM See Note * #4-600 MCM 22 60 6 Fig. 1 78205118255 R1072 HCC 400 3Ø/4W 10K #4-600 MCM See Note * #4-600 MCM 22 72 6 Fig. 1 78205108075 R1096 HCC 400 3Ø/4W 10K #4-600 MCM See Note * #4-600 MCM 22 96 6 Fig. 1 78205118275 R1036 HDD 600 3Ø/4W 10K (2) #4-600 MCM See Note * (2) #4-600 MCM 28 1 /2 36 6 Fig. 1 78205118285 R1048 HDD 600 3Ø/4W 10K (2) #4-600 MCM See Note * (2) #4-600 MCM 28 1 /2 48 6 Fig. 1 78205118295 R1060 HDD 600 3Ø/4W 10K (2) #4-600 MCM See Note * (2) #4-600 MCM 28 1 /2 60 6 Fig. 1 78205118305 R1072 HDD 600 3Ø/4W 10K (2) #4-600 MCM See Note * (2) #4-600 MCM 28 1 /2 72 6 Fig. 1 78205131978 R1096 HDD 600 3Ø/4W 10K (2) #4-600 MCM See Note * (2) #4-600 MCM 28 1 /2 96 6 Fig. 1 78205118150 R10120 HDD 600 3Ø/4W 10K (2) #4-600 MCM See Note * (2) #4-600 MCM 28 1 /2 120 6 Fig. 1 78205118375 R1048 HEE 800 3Ø/4W 10K (3) #4-600 MCM See Note * (3) #4-600 MCM 28 1 /2 48 6 Fig. 1 78205118385 R1060 HEE 800 3Ø/4W 10K (3) #4-600 MCM See Note * (3) #4-600 MCM 28 1 /2 60 6 Fig. 1 78205118395 R1072 HEE 800 3Ø/4W 10K (3) #4-600 MCM See Note * (3) #4-600 MCM 28 1 /2 72 6 Fig. 1 78205118401 R1096 HEE 800 3Ø/4W 10K (3) #4-600 MCM See Note * (3) #4-600 MCM 28 1 /2 96 6 Fig. 1 78205118160 R10120 HEE 800 3Ø/4W 10K (3) #4-600 MCM See Note * (3) #4-600 MCM 28 1 /2 120 6 Fig. 1 78205131970 R1060 HFF 1200 3Ø/4W 10K (4) #4-600 MCM See Note * (4) #4-600 MCM 36 60 6 Fig. 1 78205131972 R1072 HFF 1200 3Ø/4W 10K (4) #4-600 MCM See Note * (4) #4-600 MCM 36 72 6 Fig. 1 78205118200 R1096 HFF 1200 3Ø/4W 10K (4) #4-600 MCM See Note * (4) #4-600 MCM 36 96 6 Fig. 1 78205118170 R10120 HFF 1200 3Ø/4W 10K (4) #4-600 MCM See Note * (4) #4-600 MCM 36 120 6 Fig. 1 78205131974 R1072 HGG 1600 3Ø/4W 10K (6) #4-600 MCM See Note * (6) #4-600 MCM 36 72 8 Fig. 1 78205118205 R1096 HGG 1600 3Ø/4W 10K (6) #4-600 MCM See Note * (6) #4-600 MCM 36 96 8 Fig. 1 78205118190 R10120 HGG 1600 3Ø/4W 10K (6) #4-600 MCM See Note * (6) #4-600 MCM 36 120 8 Fig. 1 78205131976 R1072 HHH 2000 3Ø/4W 10K (6) #4-600 MCM See Note * (6) #4-600 MCM 36 72 8 Fig. 1 78205118210 R1096 HHH 2000 3Ø/4W 10K (6) #4-600 MCM See Note * (6) #4-600 MCM 36 96 8 Fig. 1 78205118195 R10120 HHH 2000 3Ø/4W 10K (6) #4-600 MCM See Note * (6) #4-600 MCM 36 120 8 Fig. 1 Note: * 5 /16 mounting holes for load lugs - single location per phase per foot of width. Note: Every 600 MCM lug barrel will accept (2) 1/0-250 MCM cables 49

Universal Bussed Gutters 400-2000 Amp R1024 R1036 R1048 R1060 R1072 R1096 R10120 Style # Suffixes SS - Stainless Steel /CU - Copper Buss Layouts Fig. 1 All cabinets 60 and wider have two (2) doors. Cabinets 48 wide and 28 1 /2 tall also have two (2) doors. 50

Bussed Gutters - For TB/MTB Units 400-800 Amp R1123HCC (closed) R1123HCC (open) Application Used as a distribution point for multiple load applications under a common feed Surface mount Construction NEMA Type 3R ANSI 61 gray E-coat finish Aluminum bussing Standards UL 1773 Listed Part/UPC Catalog Buss Service Connections Overall Dimensions Knockout Number Number Amps Type Positions Line Load Neutral Height Width Depth Layout 78205157083 R1122 HC 400 1Ø/3W 2 #4-600 MCM #6-600 MCM #4-600 MCM 13 28 3 /8 6 Fig. 1 78205157087 R1123 HC 400 1Ø/3W 3 #4-600 MCM #6-600 MCM #4-600 MCM 13 42 3 /4 6 Fig. 2 78205157089 R1123 HD 600 1Ø/3W 3 (2) #4-600 MCM #6-600 MCM (2) #4-600 MCM 22 42 3 /4 6 Fig. 2 78205157091 R1124 HD 600 1Ø/3W 4 (2) #4-600 MCM #6-600 MCM (2) #4-600 MCM 22 57 6 Fig. 3 78205157107 R1125 HD 600 1Ø/3W 5 (2) #4-600 MCM #6-600 MCM (2) #4-600 MCM 22 71 1 /4 6 Fig. 4 78205157111 R1126 HD 600 1Ø/3W 6 (2) #4-600 MCM #6-600 MCM (2) #4-600 MCM 22 85 5 /8 6 Fig. 5 78205157093 R1124 HE 800 1Ø/3W 4 (3) #4-600 MCM #6-600 MCM (3) #4-600 MCM 22 57 6 Fig. 3 78205157109 R1125 HE 800 1Ø/3W 5 (3) #4-600 MCM #6-600 MCM (3) #4-600 MCM 22 71 1 /4 6 Fig. 4 78205157113 R1126 HE 800 1Ø/3W 6 (3) #4-600 MCM #6-600 MCM (3) #4-600 MCM 22 85 5 /8 6 Fig. 5 78205157097 R1122 HCC 400 3Ø/4W 2 #4-600 MCM #6-600 MCM #4-600 MCM 22 28 3 /8 6 Fig. 1 78205157099 R1123 HCC 400 3Ø/4W 3 #4-600 MCM #6-600 MCM #4-600 MCM 22 42 3 /4 6 Fig. 2 78205157101 R1123 HDD 600 3Ø/4W 3 (2) #4-600 MCM #6-600 MCM (2) #4-600 MCM 22 42 3 /4 6 Fig. 2 78205157103 R1124 HDD 600 3Ø/4W 4 (2) #4-600 MCM #6-600 MCM (2) #4-600 MCM 22 57 6 Fig. 3 78205157115 R1125 HDD 600 3Ø/4W 5 (2) #4-600 MCM #6-600 MCM (2) #4-600 MCM 22 71 1 /4 6 Fig. 4 78205157119 R1126 HDD 600 3Ø/4W 6 (2) #4-600 MCM #6-600 MCM (2) #4-600 MCM 22 85 5 /8 6 Fig. 5 78205157103 R1124 HEE 800 3Ø/4W 4 (3) #4-600 MCM #6-600 MCM (3) #4-600 MCM 28 1 /2 57 6 Fig. 3 78205157117 R1125 HEE 800 3Ø/4W 5 (3) #4-600 MCM #6-600 MCM (3) #4-600 MCM 28 1 /2 71 1 /4 6 Fig. 4 78205157121 R1126 HEE 800 3Ø/4W 6 (3) #4-600 MCM #6-600 MCM (3) #4-600 MCM 28 1 /2 85 5 /8 6 Fig. 5 Notes: All TB/MTB bussed gutters are rated at 10K AIC. All units have (1) #6-250 MCM ground lug secured to the neutral. Every 600 MCM lug barrel will accept (2) 1/0-250 MCM cables. 51

Bussed Gutters - For TB/MTB Units 400-800 Amps R1122 R1123 R1124 R1125 R1126 Style # Suffixes SS - Stainless Steel /CU - Copper Buss Knockout Layouts Fig. 1 Fig. 2 Fig. 6 (4) Fig. 6 (6) Fig. 3 Fig. 4 Fig. 6 (8) Fig. 6 (10) Fig. 5 11 /32 7 /16 Fig. 6 Clover Leaf Knockout 45 3 /16 45 Fig. 6 (12) 3 Diameter 52

Termination Enclosures 100-1200 Amp R9000EE (closed) R9000EE (open) Application For termination of utility supply cables Used as a termination point before bussed gutters in underground applications Surface mount Construction NEMA Type 3R ANSI 61 gray E-coat finish Aluminum bussing Removable door with sealing provision and lifting handles Standards UL 1773 Listed EUSERC 343 EUSERC 343A Part/UPC Catalog Amp Service Phase & Neutral Connections Overall Dimensions Knockout Number Number Rating Type Access AIC Line Load Height Width Depth Layout 78205153196 R9007 A 100 1Ø or 3Ø/3W UG 10K #14-2/0 #14-2/0 8 12 4 Fig. 1 78205158183 R9000 B 200 1Ø or 3Ø/3W UG 10K #6-250 MCM #6-250 MCM 26 12 6 Fig. 1 78205153189 R9000 BB 200 3Ø/4W UG 10K #6-250 MCM #6-250 MCM 26 16 6 Fig. 1 78205153184 R9000 C 400 1Ø or 3Ø/3W UG 42K 2 Studs / Ø #6-600 MCM 44 12 7 Fig. 1 78205153190 R9000 CC 400 3Ø/4W UG 42K 2 Studs / Ø #6-600 MCM 44 18 7 Fig. 1 78205153186 R9000 E 800 1Ø or 3Ø/3W UG 65K 4 Studs / Ø (3) #4-600 MCM 52 18 11 Fig. 1 78205153192 R9000 EE 800 3Ø/4W UG 65K 4 Studs / Ø (3) #4-600 MCM 52 26 11 Fig. 1 78205153188 R9000 F 1200 1Ø or 3Ø/3W UG 65K 6 Studs / Ø (4) #4-600 MCM 52 24 11 Fig. 1 78205153194 R9000 FF 1200 3Ø/4W UG 65K 6 Studs / Ø (4) #4-600 MCM 52 36 11 Fig. 1 78205107197 R9000 CL 400 1Ø or 3Ø/3W OH/UG 42K #4-600 MCM #4-600 MCM 44 12 7 Fig. 1 78205107200 R9000 CCL 400 3Ø/4W OH/UG 42K #4-600 MCM #4-600 MCM 44 18 7 Fig. 1 78205107198 R9000 EL 800 1Ø or 3Ø/3W OH/UG 65K (3) #4-600 MCM (3) #4-600 MCM 52 18 11 Fig. 1 78205107201 R9000 EEL 800 3Ø/4W OH/UG 65K (3) #4-600 MCM (3) #4-600 MCM 52 26 11 Fig. 1 78205107199 R9000 FL 1200 1Ø or 3Ø/3W OH/UG 65K (4) #4-600 MCM (3) #4-600 MCM 52 24 11 Fig. 1 78205107202 R9000 FFL 1200 3Ø/4W OH/UG 65K (4) #4-600 MCM (3) #4-600 MCM 52 36 11 Fig. 1 Notes: UG units comply with EUSERC 343A. OH/UG units comply with EUSERC 343. Every 600 MCM lug barrel will accept (2) 1/0-250 MCM cables. 53

Termination Enclosures 100-1200 Amp R9000 Style # Suffixes SS - Stainless Steel Layouts Fig. 1 52 tall cabinets have two (2) overlapping doors as shown on the R9000EE photo (page 53) 54