Puzzling Pacemakers Cheryl Herrmann, APN, CCRN, CCNS-CSC-CMC

Similar documents
PACEMAKER INTERPRETATION AND DEVICE MANAGEMENT PART I

Figure 2. Normal ECG tracing. Table 1.

Pacing Codes and Modes Concepts

Pediatric pacemakers & ICDs:

Timing cycles. Objectives Upon completion of this program the participant will be able to:

Presented By: Barbara Furry, RN-BC, MS, CCRN, FAHA Director The Center of Excellence in Education Director of HERO

RN-BC, MS, CCRN, FAHA

SARASOTA MEMORIAL HOSPITAL

Cardiac Rhythm Device Management. PBL STOP Your acronym for a standardized follow-up

ΤΟ ΗΚΓ ΣΤΟΝ ΒΗΜΑΤΟΔΟΤΟΥΜΕΝΟ ΑΣΘΕΝΗ

Temporary pacemaker 삼성서울병원 심장혈관센터심장검사실 박정왜 RN, CCDS

TEMPORARY PACEMAKERS HINTS ( DUAL CHAMBER 5392 PACER)

INTERPRETING THE ECG IN PATIENTS WITH PACEMAKERS

MODEL EPG SINGLE CHAMBER TEMPORARY EXTERNAL PACEMAKER

The heart's "natural" pacemaker is called the sinoatrial (SA) node or sinus node.

Electrocardiography for Healthcare Professionals

EHRA Accreditation Exam - Sample MCQs Cardiac Pacing and ICDs

Ass. Prof. Tomon Thongsri, MD Buddhachinaraj Phitsanuloke Hospital

Review of Pacemakers and ICD Therapy: Overview and Patient Management

PERMANENT PACEMAKERS AND IMPLANTABLE DEFIBRILLATORS Considerations for intensivists

Contents. Example: Pacemaker in DDD Mode. I. Introduction II. Website and Relevant Documents III. Background Information IV.

Is This Thing Working?

Chapter 80 Implantable Cardiac Devices

ICD: Basics, Programming and Trouble-shooting

MEDTRONIC CARELINK NETWORK FOR PACEMAKERS. Comparison between the Medtronic CareLink Network for Pacemakers and Transtelephonic Monitoring

Model 5392 EPG Temporary Pacer

Permanent Pacemaker Implantation Post Cardiac Surgery: A Cautionary Tale

Pacing and Device Jargon Made Simple. Dr Jonathan Timperley MB ChB MD FRCP Consultant Cardiologist Northampton General Hospital

Temporary Pacemakers

Implant Procedure Concepts

Sinus rhythm with premature atrial beats 2 and 6 (see Lead II).

Cardiac Assist Devices. Wayne E. Ellis, Ph.D., CRNA

Project Title Temporary Pacemaker Training Simulator

PACEMAKER INTERPRETATION AND DEVICE MANAGEMENT PART II

Pacemakers 12/04. Pacemakers. 1. What is a pacemaker?

Intermittent episodes of paced tachycardia: what is the cause?

The Cardiac Pacemaker Case Study and its implementation in Safety-Critical Java and Ravenscar Ada

Pacemaker Concepts and Terminology*

PERIOPERATIVE MANAGEMENT: CARDIAC PACEMAKERS AND DEFIBRILLATORS

Size (mm) (H W D) Mass (g) Volume (cc)

Essentials of Pacemakers and ICD s. Rajesh Banker, MD, MPH

Pacing Lead Implant Testing. Document Identifier

Advanced ICD Concepts

Need to Know: Implantable Devices. Carolyn Brown RN, MN, CCRN Education Coordinator Emory Healthcare Atlanta, Georgia

Title and contents page 1 Who should read this document 2 Scope of the Guideline 2 Background 2 What is new in this version 2

Review Packet EKG Competency This packet is a review of the information you will need to know for the proctored EKG competency test.

BEDSIDE ECG INTERPRETATION

Temporary pacemaker : Programming &Trouble shooting

TIP CARD. Model Temporary External Pacemaker

Supplemental Material

Practice Questions.

-RHYTHM PRACTICE- By Dr.moanes Msc.cardiology Assistant Lecturer of Cardiology Al Azhar University. OBHG Education Subcommittee

Cardiac Pacing. Learning outcomes. Introduction. The cardiac impulse - its formation and its failure CHAPTER. To understand:

ECG Interpretation. Introduction to Cardiac Telemetry. Michael Peters, RN, CCRN, CFRN CALSTAR Air Medical Services

Answer: The electrical current has difficulty traveling down the normal conduction pathway.

2017 BDKA Review. Regularity Rate P waves PRI QRS Interpretation. Regularity Rate P waves PRI QRS Interpretation 1/1/2017

Newer pacemakers also can monitor your blood temperature, breathing, and other factors and adjust your heart rate to changes in your activity.

CRC 431 ECG Basics. Bill Pruitt, MBA, RRT, CPFT, AE-C

Timothy Graham, M.D. Case Western Reserve University School of Medicine University Hospitals Case Medical Center Cleveland, Ohio

You have a what, inside you?

The Nuts and Bolts of ICD Therapy

CORONARY ARTERIES. LAD Anterior wall of the left vent Lateral wall of left vent Anterior 2/3 of interventricluar septum R & L bundle branches

1 Cardiology Acute Care Day 22 April 2013 Arrhythmia Tutorial Course Material

Full file at

You have a what, inside you?

DEFIBRILLATORS. Prof. Yasser Mostafa Kadah

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

12 th International Winter Arrhythmia School Collingwood, Ontario February 7, Dr. Derek Yung. MD, FRCPC

SJM MRI ACTIVATOR HANDHELD DEVICE WORKFLOW Model: EX4000. SJM-EDTR Item approved for U.S. use only.

NEIL CISPER TECHNICAL FIELD ENGINEER ICD/CRTD BASICS

CONSULTA CRT-P Model C4TR01

Antibradycardia Pacemakers

Specified Tolerance (ms)

EnTrust D154VRC Single Chamber ICD 35J delivered 8 seconds BOL, 11.8 seconds ERI 10.7 years**** 35cc, 68g Programmable Active Can

Course Objectives. Proper Lead Placements. Review the ECG print paper. Review the mechanics of the Myocardium. Review basics of ECG Rhythms

PRACTICE advisories are systematically developed reports

Supplementary Online Content

09/05/2018. True/False: All pacemakers have defibrillation capabilities.

Electrocardiography for Healthcare Professionals

Biventricular Pacemakers Sensing

8/20/2012. Learning Outcomes (Cont d)

CORONARY ARTERIES HEART

PATIENT WITH ARRHYTHMIA IN DENTIST S OFFICE. Małgorzata Kurpesa, MD., PhD. Chair&Department of Cardiology

12/1/2010. Human Heart. CS5219 Term Project Pacemaker: Modeling and Verification. Natural Pacemaker. Bradycardia

Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing. D. J. McMahon cewood rev

A Rare Type of Pacemaker Mediated Tachycardia

Transcutaneous Pacing on Zoll Defibrillator Version 4 Related Documents SOP-Zoll defibrillator ; Phillips MRX SOP Dr Randal McRoberts

Cardiac Implanted Electronic Devices Pacemakers, Defibrillators, Cardiac Resynchronization Devices, Loop Recorders, etc.

11/21/18. EKG Pop Quiz. Michael Giocondo, MD Cardiac Electrophysiology Saint Luke s Cardiovascular Consultants

MONITORING PATIENTS WITH A TEMPORARY EXTERNAL EPICARDIAL PACEMAKER PURPOSE POLICY STATEMENTS SITE APPLICABILITY PRACTICE LEVEL/COMPETENCIES

Dual Chamber Temporary External Pacemaker

Friedman, Rott, Wokhlu, Asirvatham, Hayes 201. Figure 65.7 Shortening of the AV interval during pacing.

Programming of Bradycardic Parameters. C. W. Israel, M.D. Dept. of Cardiology Evangelical Hospital Bielefeld Germany

Troubleshooting ICD. NASPE Training Lancashire & South Cumbria Cardiac Network

The Electrocardiogram

Arrhythmias. Pulmonary Artery

FRONTIER II. User s Manual. Model 5586 Model Biventricular Cardiac Resynchronization Device with AF Suppression Algorithm

856 Unintentional Deactivation of ICDs Mayo Clin Proc, August 2002, Vol 77 Figure 1. Case 3. Printout from Guidant programmer (Guidant Corp, St Paul,

DEFIBRILLATORS ATRIAL AND VENTRICULAR FIBRILLATION

ISO INTERNATIONAL STANDARD. Implants for surgery Active implantable medical devices Part 2: Cardiac pacemakers

Transcription:

Puzzling Pacemakers Cheryl Herrmann, APN, CCRN, CCNS-CSC-CMC Pacemaker: An electric device implanted in the body to regulate the heart beat. Delivers electrical stimuli over leads with electrodes in contact with the heart Consists of a generator and leads Generator Mini computer with power source Leads Electrical wires used to transmit electrical data back & forth from the heart to the pulse generator The NASPE/BPEG generic (NBG) code Position I II III IV V Category Chamber(s) Paced Chamber(s) sensed Response to Sensing Programmability, Rate Antitachyarrhythmia Letters used A = Atrium V = Ventricle D = Dual (A+V) A = Atrium V = Ventricle D = Dual (A+V) T= Triggered I = Inhibited D = Dual (T+I) First Letter: Indicates what leads are available to pace A = Atrium V = Ventricle D = Dual (A+V) Modulation P = Simple Programmable M = Multi- Programmable C = Communicating R = Rate modulation Functions P = Pacing (antitachyarrhythmia S = Shock D = Dual (P+S) Second Letter: Indicates which chamber that the pulse generator will monitor for spontaneous depolarization A = Atrium V = Ventricle D = Dual (A+V) Third Letter: Indicates what the pacemaker will do when it senses an event Asynchronous pacing Also called fixed rate or magnet mode Delivers a pacing stimulus at a fixed rate regardless of the heart s intrinsic activity It will cause competition with the heart s intrinsic activity, and the pacing stimulus may land during the descending limb of the T-wave

T = Triggered When the pacemaker activates a depolarization wave to a sensed event An example of a triggered response is when the pacemaker fires an impulse to the ventricles after it senses an atrial depolarization I = Inhibited Demand or synchronous pacing Pacemaker responds to a sensed event by NOT firing a response for a certain amount of time. Paces only when patient s heart rate falls below set rate Avoids R on T phenomenon and ventricular dysrhythmias D = Dual (T+I) Pacemaker can respond in a triggered manner for some pre-programmed cases and in an inhibitory manner for other pre-programmed events Codes are combined to describe: The mode of pacing The mode of sensing How the pacemaker will respond to the presence or absence of intrinsic beats AOO AAI VOO VVI Pacemaker Indications Junctional Rhythms Second-degree AV block -- Mobitz type II Third-degree AV block SA node conduction problems Heart Failure with ventricular dysynchrony Single-Chamber Systems The pacing lead is implanted in the atrium or ventricle, depending on the chamber to be paced and sensed VVI Ventricular Demand Pacing Pacer spike should be just before the QRS when no intrinsic event sensed Ventricular Sensing Sensed intrinsic QRS inhibits ventricular pacing Used as backup pacing Does not provide AV synchrony -- may get pacemaker syndrome

AAI Atrial Demand Pacing Pacer spike should be just before the p wave when no intrinsic event sensed Atrial Sensing Sensed intrinsic p wave inhibits atrial pacing Used to provide atrial contraction with SA node conduction problems AOO Atrial asynchronous pacing at programmed pacing rate No Sensing Used to provide atrial contraction with SA node conduction problems Dual-Chamber Systems The pacing leads are implanted in both the atrium and ventricle. DDD Pacing in both the atrium and ventricle Pacer spike should be just before the p wave when no intrinsic event sensed Pacer spike should be just before the QRS when no intrinsic event sensed Sensing in both the atrium and ventricle Intrinsic p wave and intrinsic QRS can inhibit pacing Intrinsic p wave can trigger a paced QRS Four Functions (faces) of DDD Pacing: 1. Atrial Sense, Ventricular Sense (AS/VS) Native atrial and ventricular depolarization present. No pacing needed. 2. Atrial Pace, Ventricular Sense (AP/VS) No atrial depolarization present. Atrial pacing occurs. Native ventricular depolarization present. Good for junctional rhythms 3. Atrial Sense, Ventricular Pace (AS/ VP) Native atrial depolarization present. No atrial pacing needed. No ventricular depolarization present. Ventricular pacing occurs. Good for complete heart block or Mobitz II 4. Atrial Pace, Ventricular Pace (AP/VP) No atrial or ventricular depolarization present. Atrial and ventricular pacing occurs. Good for SA arrest, asystole

These four functions occur on a beat to beat basis depending on the conduction system of the individual s heart. AP/VP AS/VP AS/VS AP/VS DDI or DDIR Paces both the atrium and ventricle Senses atrial and ventricle however does not track the atrium. Good with for high atrial rates to prevent a high ventricular response (atrial tachyarrhythmias) DVI: Paces both the atrium and ventricle No atrial sensing --- does not track the atrium. Senses ventricle Not commonly used. Good when atria silent. DOO Atrial and ventricular asynchronous pacing at programmed pacing rate No Sensing of the atrium or ventricle Used when no attempt to synchronize paced events with intrinsic activity Contraindicated in the case of a competing intrinsic rhythm Good when individual is pacer dependent Pacemaker Terminology & Troubleshooting MA (Milliamps) The amount of energy needed to make the heart depolarize with the electrode (capture) Range from 0.1-20 Usually set just above a patient s threshold to ensure a good capture Threshold is the minimal output required to capture the heart. On DDD pacemakers the MA is set for both the atrium and ventricle

Threshold Level The minimum stimulus required to cause stimulation of the myocardium (pacing) or minimum voltage for an intrinsic complex to be sensed. Also known as stimulation threshold Fire The spike that is produced when the pacemaker elicits an electrical stimulus Capture An effective, consistent cardiac depolarization of the heart caused by the pacemaker s electrical stimulus To assess capture it is necessary to see pacemaker spikes followed by depolarization For example an atrial spike followed by a p wave or a ventricular spike followed by a QRS. Failure to Capture The presence of one or more pacer spikes that are not followed by an appropriately timed atrial and/or ventricular response Treatment: failure to capture Increase MA until capture present o Transvenous pacing typically requires MA 3 5 to capture o Epicardial pacing typically requires MA 10 20 o Transcutaneous (external) pacing typically requires MA 60 100 o Permanent pacing typically requires MA 3-5 Transvenous Pacing o Have patient change positions to see if the lead will float back to make contact with the ventricular wall Epicardial Pacing o After increasing MA, try switching polarity of wires. The negative lead is the wire that paces and the positive lead is the wire that is providing the ground. o If only one epicardial wire is functional, place a skin lead. This lead should be in the positive pole. Permanent Pacing o May be a dislodged lead All Pacing treat underlying conditions o Acidosis o Electrolyte imbalances especially hyperkalemia

Sensing/Sensitivity Sensing is the ability of the pacemaker to see when an intrinsic depolarization is occurring. The level at which intrinsic atrial or ventricular activity is recognized by the sensing electrodes; the lower the number, the greater the sensitivity With proper sensing, no pacer spike should occur during the escape interval Undersensing (Failure to Sense) Undersensing leads to overpacing Pacemaker does not see or missed the intrinsic beat, and responds with a spike Pacemaker spikes where they should not be. Treatment of Undersensing Decrease the sensitivity (millivolt setting) to make the pacemaker more sensitive The lower the number, the greater the sensitivity If the ventricular mv is set at 2 mv, the pacemaker will not see any QRS that is less than 2mV. If the QRS is small, the mv needs to be decreased to make the pacer more sensitive and see all the QRSs. Check all connections and batteries on temporary pacemakers. With epicardial pacing, try switching polarity. Oversensing (Failure to Pace) Oversensing leads to underpacing Pacemaker sees complexes that are not p waves or QRSs and stops the pacer from firing or delivering a spike. An electrical signal other than the intended P or R wave is detected. For example a peaked T wave may be detected as an R wave. On EKG, an inappropriate long pause between pacing spikes

Treatment of Oversensing Increase the sensitivity (millivolt setting) to make the pacemaker less sensitive The higher the number, the less the sensitivity If the ventricular mv is set at 2 mv, the pacemaker will detect any complex that is greater than 2mV and stops the pacer from firing or delivering a spike. Typically this is a peaked T wave so the mv needs to be increased to number larger than the mv of the T wave. Failure to Pace not related to sensitivity settings The absence of packing artifacts when the intrinsic heart rate is slower than the pacemakers set rate. Treatment: Failure to pace Temporary Pacemakers o Change the battery as many times it is a dead battery o Check for loose or disconnected lead connections o With epicardial pacing, if only one epicardial wire is functional, place a skin lead. This lead should be in the positive pole. Permanent Pacemaker o Battery may need to be changed or leads may be fractured Timing Intervals When the pacemaker senses an atrial or ventricular complex, it starts the stopwatch of the generator. The stopwatch starts to measure a pre-designated amount of time during which the pacemaker will not fire Atrial and Ventricular Intervals A - A interval V- V Interval V- A Interval AV Interval Refractory Periods In pacing, a programmable parameter that controls the length of time following a paced or sensed beat, during which the pacemaker s sensing circuit does not respond to sensed events. PVARP=Post Ventricular Atrial Refractory Period=atrial refractory period VRP=Ventricular Refractory Period Rate Intervals Lower Rate Defines the lowest rate the pacemaker will pace Upper Rate Defines the shortest interval (highest rate) the pacemaker can pace as dictated by the sensor

Atrial Tracking Ventricular pacing rate follows or tracks the atrial activity Provides AV synchrony to get the benefit of the atrial kick (contraction) or 15 20% more of the cardiac output and thus prevents pacemaker syndrome If the atrial rate exceeds the upper rate limit, the pacer will postpone a ventricular output pulse until the upper rate limit interval times out. It does this by causing a paced Wenckebach or paced Mobitz II Steps to interpret Pacemaker rhythms 1. Select the lead in which the pacemaker spike(s) is seen the best 2. Identify the pacemaker spikes a. Atrial spikes should be noted immediately before the p wave b. Ventricular spikes should be noted immediately before the QRS c. Dual chamber pacing --- may or may not have two spikes depending on the intrinsic activity 3. After identifying the pacer spikes as atrial and/or ventricular, note where they are falling in relation to the p wave and to the QRS. Are they falling where they should be? If not, where are they falling and why. 4. When the pacer spikes are not falling where they should be then be prepared to treat immediately. 5. Is there capture? 6. What are the pacemaker settings including rate?

ICD: Internal Cardiac Defibrillator Treats tachydysthythmias by tiered functions Antitachycardia Pacing o The device fires a preset number of rapid pulses in succession in an attempt to terminate the ventricular tachycardia Cardioversion/Defibrillation at low voltage Back up pacing for bradyarrhythmias post cardioversion or defibrillation Pacemaker Magnet Mode When a magnet is applied the pacemaker paces asynchronously (no sensing) The pacemaker returns to previously programmed settings when the magnet is removed. The magnet mode is used to check the programming of the pacemaker and the battery life When a patient places the magnet over his device, it will go asynchronous to get a pacemaker strip to determine how well the device is functioning. A magnet does not turn off a pacemaker. A pacemaker is only turned off with a programming device. ICD Magnet Mode Magnet application will NOT affect the Brady pacing function- it will continue as programmed. ICD magnet placement will disable the sensing function of the device and therefore- no therapy will be delivered It will continue to pace but will not defibrillate Once the magnet is removed, Tachy function will be enabled (restored) When to use the magnet in ICDs: Inappropriate Shocks Use until the company representative can interrogate the device and determine the cause for the inappropriate shocks Surgery: patient must be on monitor in the OR Suite and Turned back on in Recovery Area End stage disease states/hospice care (Physician ordered) www.cherylherrmann.com March 2014