CLINIQCT NO-DOSE CT BONE DENSITOMETRY FOR ROUTINE AND SPECIALIST USE.

Similar documents
LOW-DOSE CT BONE DENSITOMETRY FOR ROUTINE AND SPECIALIST USE

QCT and CT applications in Osteoporosis Imaging

Bone Investigational Toolkit BIT. Biomechanical Bone Integrity Assessment

Clinical Study Comparison of QCT and DXA: Osteoporosis Detection Rates in Postmenopausal Women

Prevalence of Osteoporosis p. 262 Consequences of Osteoporosis p. 263 Risk Factors for Osteoporosis p. 264 Attainment of Peak Bone Density p.

3 - D i m e n s i o n a l V o l u m e t r i c Q C T B o n e D e n s i t o m e t r y o f t h e H i p a n d S p i n e

Introducing the future of DXA. Powerful images. Clear answers. Horizon DXA System

EXAMINATION CONTENT SPECIFICATIONS ARRT BOARD APPROVED: JANUARY 2017 IMPLEMENTATION DATE: JULY 1, 2017

STRUCTURED EDUCATION REQUIREMENTS IMPLEMENTATION DATE: JULY 1, 2017

The Bone Densitometry Examination

2013 ISCD Official Positions Adult

Quantitative Computed Tomography 4 Introduction

Interpreting DEXA Scan and. the New Fracture Risk. Assessment. Algorithm

Bone Densitometry. Total 30 Maximum CE 14. DXA Scanning (10) 7

DXA When to order? How to interpret? Dr Nikhil Tandon Department of Endocrinology and Metabolism All India Institute of Medical Sciences New Delhi

9 Quality Assurance in Bone Densitometry section

Advanced Point-of-Care Bone Health Assessment HOLOGIC OSTEOPOROSIS ASSESSMENT

QDR Series. Discovery and Explorer Advanced Health Assessment

Norland Densitometry A Tradition of Excellence

Preliminary technical data

2013 ISCD Combined Official Positions

LUMBAR IS IT IMPORTANT? S. Tantawy,, M.D.

Documentation, Codebook, and Frequencies

Bone Densitometry. What is a Bone Density Scan (DXA)? What are some common uses of the procedure?

QCT BMD Imaging vs DEXA BMD Imaging

Healthy aging. It s vital.

Bone Mineral Densitometry with Dual Energy X-Ray Absorptiometry

Prodigy. from GE Healthcare. Most trusted, reliable and best-selling DXA system with one of the largest installed base in the world. gehealthcare.

Quality Control of DXA System and Precision Test of Radio-technologists

Powerful images. Clear answers.

Bone Densitometry at the Point of Care

DELPHI. The standard in point-of-care fracture risk assessment. Now with Image Pro.

Bone Mass Measurement BONE MASS MEASUREMENT HS-042. Policy Number: HS-042. Original Effective Date: 8/25/2008

Bone Densitometry Equipment Operator

Effect of Precision Error on T-scores and the Diagnostic Classification of Bone Status

Module 5 - Speaking of Bones Osteoporosis For Health Professionals: Fracture Risk Assessment. William D. Leslie, MD MSc FRCPC

vertaplan the spine surgeon s software vertaplan System for successful reconstruction of the individual sagittal balance

Identification of Early Osteoporosis Using Intensity Slicing method

Volumetric Quantitative CT of the Spine and Hip Derived from Contrast-Enhanced MDCT: Conversion Factors

PhenX Measure: Body Composition (#020300) PhenX Protocol: Body Composition - Body Composition by Dual-Energy X-Ray Absorptiometry (#020302)

WITH. The Next Step in Office MRI

DXA Best Practices. What is the problem? 9/29/2017. BMD Predicts Fracture Risk. Dual-energy X-ray Absorptiometry: DXA

Objectives: What is Osteoporosis 10/8/2015. Bone Health/ Osteoporosis: BASICS OF SCREENING, INTERPRETING, AND TREATING

Comparison of Bone Density of Distal Radius With Hip and Spine Using DXA

Clinical Appropriateness Guidelines: Advanced Imaging

THE DIAGNOSIS OF OSTEOPOROSIS BY MEASURING LUMBAR VERTEBRAE DENSITY WITH MDCT: A COMPARATIVE STUDY WITH QUANTITATIVE COMPUTERIZED TOMOGRAPHY (QCT)

For true visualisation

Mineral Density Of Subchondral Bone May Be Quantitatively Evaluated Using A Clinical Cone Beam Computed Tomography Scanner

Journal of Bone and Mineral Research 12: , Non-Invasive Bone Mass Measurement: Techniques and Applications

Clinical Application of Computed Radiography in Orthopedic Surgery

Annotations Part III Vertebral Fracture Initiative. International Osteoporosis Foundation March 2011

L.W. Sun 1,2, G. Beller 1, D. Felsenberg 1. Introduction. Original Article. Abstract

EVALUATION OF THE CORTICAL BONE THICKNESS IN LUMBAR VERTEBRA USING CT AND RP EXPERIMENTAL TECHNIQUES

ReviewArticle. Frequently Asked Questions About Bone Mineral Density Test

Accuracy of DEXA scanning & other methods for determining BMD.

ANNOUNCING THE NEW STONY BROOK UNIVERSITY OUTPATIENT IMAGING CENTER

ASJ. How Many High Risk Korean Patients with Osteopenia Could Overlook Treatment Eligibility? Asian Spine Journal. Introduction

Dual-energy Vertebral Assessment

Lunar Prodigy Advance

Pioneering the future of general imaging.

Standard Operating Procedure TCRC Dual-Energy X-ray Absorptiometry (DXA)

Technical data TECHNICAL DATA

The effect of vertebral rotation of the lumbar spine on dual energy X-ray absorptiometry measurements: observational study

The New Frontier in Hip Preservation Preoperative CT-based Planning for FAI correction

Adina Alazraki, MD, FAAP Assistant Professor, Radiology and Pediatrics Emory University School of Medicine Children s Healthcare of Atlanta

Foreword...v Preface...vii Acknowledgments... xi Dedication... xiii Continuing Medical Education... xxv. Chapter 1: Densitometry Techniques...

CT Imaging at the Point-of-Care

Sponsor / Company: sanofi-aventis and Proctor & Gamble Drug substance(s): Risedronate (HMR4003)

Beyond BMD: Bone Quality and Bone Strength

Diagnostische Präzision von DXL im Vergleich zu DXA bei pmp Frauen mit Frakturen

Official Positions on FRAX

Omnisense: At Least As Good As DXA

2 Skeletal Anatomy in Densitometry

FRAX Based Guidelines: Is a Universal Model Appropriate?

Validation of in vivo cancellous bone assessment using high resolution imaging and histologic examination

Use of DXA / Bone Density in the Care of Your Patients. Brenda Lee Holbert, M.D. Associate Professor Senior Staff Radiologist

Section 4. Scans and tests. How do I know if I have osteoporosis? Investigations for spinal fractures. Investigations after you break a bone

Original Article. Ramesh Keerthi Gadam, MD 1 ; Karen Schlauch, PhD 2 ; Kenneth E. Izuora, MD, MBA 1 ABSTRACT

Advanced DXA Using TBS insight

Bone Densitometry Radiation dose: what you need to know

Osteoporosis: A Tale of 3 Task Forces!

The Key to Confidence

Evaluation of Bone Mineral Status in Adolescent Idiopathic Scoliosis

Does standardized BMD still remove differences between Hologic and GE-Lunar state-of-the-art DXA systems?

SCHEDULE 2 THE SERVICES. A. Service Specifications

NIH Public Access Author Manuscript Endocr Pract. Author manuscript; available in PMC 2014 May 11.

A basic study for automatic recognition of osteoporosis using abdominal X-ray CT images

Lunar idxa. The intelligent DXA. gehealthcare.com

Thickness Computation Under In-Vivo Trabecular Bone CT Imaging

Targeting better results

BIOTECH DENTAL GROUP, 2.0 DENTAL OFFICE PARTNER.

DEXA Scores and Bone Density Measured on Routine CT Scans

OSTEOPOROSIS IN MEN. Nelson B. Watts, MD OSTEOPOROSIS AND BONE HEALTH SERVICES CINCINNATI, OHIO

American College of Radiology ACR Appropriateness Criteria

Lunar idxa. The intelligent DXA. gehealthcare.com

Osteoporosis International. Original Article. Bone Mineral Density and Vertebral Fractures in Men

DXA scanning to diagnose osteoporosis: Do you know what the results mean?

Your Global Quality Assurance Platform All-in-One. All Connected. All Secure.

Certified Clinical Densitometrist (CCD ) DXA Resource Materials

Clinical Densitometry

Transcription:

CLINIQCT NO-DOSE CT BONE DENSITOMETRY FOR ROUTINE AND SPECIALIST USE Clinically superior BMD solutions for physicians DXA equivalent hip measurements Dual-use of standard abdominal or pelvic CT studies Adds "no patient phantom" calibration to QCT Pro TM www.qct.com

2015 Mindways Software Inc. T0087

MindwaysCT is an industry leader and innovator; providing physicians with technologies that fully enable the quantitative assessment of CT images. Incorporated in 1997, the company can trace its origins to ground-breaking work at UCSF in the late 1970s leading to the development of the Cann & Genant QCT calibration standard in the early 80 s. Today, our systems are based around the 3rd generation, solid version of the calibration phantoms that use this standard. Since its inception, MindwaysCT has been a pioneer in the industry. We were the first to develop a fully volumetric 3D Spine QCT system in 1997 and introduced the first fully functional CTXA hip system for QCT bone mineral density measurement at the proximal femur in 2001. We were also the first in the market with a QCT system that could connect to and support the storage and viewing of QCT BMD reports on PACS infrastructure. In 2012, we introduced easy to interpret reports consistent with WHO and ACR guidelines, and in 2014 we introduced our new CliniQCT asynchronous calibration technology to make QCT workflow even more efficient. With a focus on the accurate determination of tissue densities, structures and types, MindwaysCT continues with its research and development efforts in order to advance Quantitative CT (QCT) technologies for new and innovative applications. J Keenan Brown, Ph.D. CEO, Mindways Software, Inc. 2

Mindways QCT bone density measurement included in FRAX The World Health Organisation (WHO) Fracture Risk Assessment Tool (FRAX ) is a web-based tool used to calculate absolute fracture risk to ensure that people with the greatest chance of breaking a bone are treated. The tool was developed to help health care providers determine the chances of a patient breaking their hip or another major bone within a ten year period. The inclusion of Mindways QCT bone density measurement into FRAX, now offers patients and physicians an accurate and costeffective alternative assessment method for determining osteoporotic fracture risk.

More Efficient Bone Densitometry QCT with asynchronous calibration Asynchronous calibration QCT Quantitative Computed Tomography (QCT) is one of three methods cited by the National Osteoporosis Foundation as safe and effective for the evaluation of Bone Mineral Density (BMD). QCT is a fast, non-invasive BMD exam that utilizes a standard CT scanner. Asynchronous calibration is a new technology that means a calibration phantom does not need to be present on the table during the QCT scan. CliniQCT means better workflow and efficient re-use of CT scans acquired for other purposes. The QCT Exam A QCT exam takes around 5 minutes and is very similar to an ordinary CT scan. During the exam, both the spine and hip are scanned for diagnosis of low bone mass (osteopenia) or osteoporosis. Low-dose CT scan protocols are used and so the amount of radiation required is around 500-800µSv or comparable to a set of mammograms. All the work, including report generation, is carried out by a CT technician. In addition, the exam can be combined with other (non-iv contrast) abdominal/pelvic scans such as CT Colonography with no further image acquisition or radiation dose to the patient. Patient benefits: how does QCT compare? At the hip, QCT produces BMD T-score measurements that are the same as DXA measurements. QCT differs from DXA, however, in that QCT is a truly 3-D bone density exam meaning QCT can measure the metabolicallyactive trabecular (spongy) interior bone separately from the dense cortical (compact) bone forming the outside bone walls. Since trabecular bone is affected earlier and to a greater degree than cortical bone, QCT is likely to detect low bone mass earlier in the spine than other bone mineral density exams. In addition, QCT spine BMD measurements can be made for patients with scoliosis; and the artificially high BMD measurements that can affect DXA due to obesity, disc space narrowing, spinal degenerative diseases, aortic calcification and osteophytes in patients with arthritis can be avoided. Return on Investment Bone Mineral Density (BMD) measurement by QCT is reimbursed for the screening of postmenopausal women every two years by Medicare in the USA under CPT code 77078. The Mindways QCT system costs around half as much as an entry-level DXA machine. Unlike DXA, a dedicated room and dedicated technician are not required and there are no on-going hardware replacement costs. More cost-effective than DXA machines Requires only 10 min of CT tech time Reimbursed by Medicare Maximize the use of your CT scanner 4

Precision Calibration A regular QA/calibration scan using a combination of two phantoms is used to calibrate patient scans and correct for non-uniformities in the CT scan field Spine Scan Any two unfractured levels of the lumbar spine between T11-L4 are imaged using a standard CT scanner. Hip Scan The pelvis from above the femoral heads to 1cm below the lesser trochanters is scanned for analysis of either hip. Trabecular Spine Analysis Trabecular bone measurement avoids interference from arthritis and degenerative diseases. High metabolic turnover of trabecular bone produces high sensitivity to change. DXA-equivalent Hip Analysis A projection of the 3D CT image produces DXA-equivalent T-score and areal BMD measurements that are included in the WHO FRAX online fracture risk tool. Spine Report The trabecular bone volumetric BMD measurements are compared to American College of Radiology guidelines. Normal data for Z-scores is provided for ages 2-90 years. Hip Report T-scores for the femoral neck are compared with the standard World Health Organization diagnostic thresholds for normal, low bone mass and osteoporosis. CliniQCT workflow using asynchronous calibration

3D Volumetric Spine BMD Trabecular bone mineral density measurement QCT measurement of the spine is a truly 3D bone density exam of only the metabolically-active trabecular bone. Since trabecular bone is affected earlier and to a greater degree than cortical bone, QCT is likely to detect low bone mass earlier in the spine than other bone mineral density exams. Volumetric measurement of the interior trabecular bone also means avoiding the artificially high BMD measurements that can affect DXA due to obesity, disc space narrowing, spine degenerative diseases, aortic calcification and osteophytes in patients with arthritis. In addition, complex deformities such as scoliosis can be handled by rotating the anatomy in software. 3D Spine studies are fast and easy. Scan times are typically under ten seconds and the automated analysis takes about two minutes. Total study times of less than ten minutes are easily attainable. The spine and hip can also be scanned in one study for further efficiency. Combine with other scans. Using our new CliniQCT asynchronous technology, non IVcontrast abdominal CT scans can be used for 3D Spine osteoporosis assessment whether you planned a bone mineral density study or not. QCT vs DXA Features at a glance Trabecular bone mineral analysis at 2-3 levels of lumbar spine between T11-L4 Measure only trabecular bone with the highest sensitivity for the earliest detection of bone loss and therapeutic response. Avoid DXA confounding factors such as DJD, osteophytosis, aortic calcifications, and scoliosis. Highly automated analysis in 1 2 minutes Precision: up to 1% Compatible with any DICOM CT or PET/CT scanner ACR guideline thresholds are used. The volumetric trabecular spine BMD measurement is compared to guideline thresholds from the American College of Radiology (ACR): BMD < 80 mg/cm 3 = osteoporosis; BMD < 120 and > 80 mg/cm 3 = low bone mass; BMD above 120 mg/cm 3 = normal. Automatically placed Trabecular ROI QCT DXA 6

Using MindwaysCT asynchronous calibration technology, bone mineral density scans may now be combined with other studies such as CT colonography screening with no additional patient time or x-ray dose.

CTXA-Hip Computed Tomography X-ray Absorptiometry CTXA-Hip produces areal BMD and T-score measures that are DXA-equivalent, so that these measures can be used in the exactly same way as DXA measures. Results are easy to use by comparing CTXA-Hip output to WHO DXA diagnostic thresholds or as an input to the online WHO FRAX fracture risk calculator. CTXA-Hip studies are fast and easy. Scan times are typically under ten seconds and the automated analysis takes about two minutes. Total study times of less than ten minutes are easily attainable. The hip and spine can also be scanned at one study for further efficiency. Combine with other scans. Using our new CliniQCT asynchronous technology, non IVcontrast pelvic CT scans can be used for CTXA- Hip osteoporosis assessment whether you planned a bone mineral density study or not. Conversion from DXA. Because CTXA produces DXA-equivalent areal BMD results, DXA-CTXA results conversion at the hip can be made in the same way as DXA-DXA conversion if necessary. Patient positioning is easier. For those patients have osteoarthritis at the hip or knee, rotation of the hips for a DXA scan can be difficult; impacting measurement reproducibility. Using a 3D QCT image, positioning of the hip can be done using software after the scan. CTXA-Hip generates a projection image that has the same appearance as DXA. 0-0.4-0.8-1.2 Features at a glance Bone mineral analysis of the proximal femur. Clinically equivalent to DXA Identical areal BMD measurements and ROIs to DXA, as well as comparable T-scores. Bilateral hips from a single scan. Hip positioning may be done using software Highly automated analysis in 1 2 minutes. Precision: 0.7% short-term; 1.1% long-term total hip; 1.2% long-term femoral neck. Mindways areal BMD included in WHO FRAX online fracture risk calculator Compatible with any DICOM CT or PET/CT scanner Comparison of CTXA and DXA Proximal Femur Reference Data The graph below shows the comparison of T-score measurements of the total hip made with CTXA and DXA*. T-score Average T-score versus Age -1.6 CTXA DXA -2 20 30 40 50 60 70 80 Age Normalizing the CTXA data to the DXA data results in an approximate relationship between CTXA and DXA total hip BMD estimates of: BMD CTXA = 1.006 * BMD DXA - 0.106 g/cm² * Looker AC, Orwoll ES, Johnston CC, Lindsay RL, Wahner HW, Dunn WL, Calvo MS, Harris TB, Heyse SP. Prevalence of low femoral bone density in older U.S. adults from NHANES III. J Bone Miner Res 1997; 12: 1761-1768 8

QCT Pro PACS option Increase physician access to BMD reporting The QCT Pro PACS option provides for the integration of QCT Pro into your local PACS solution. PACS Export Example This integration allows you to exploit your local PACS infrastructure to work more efficiently by providing a paperless report that can be electronically archived and retrieved, reviewed locally or remotely, delivered in electronic form to your patients or physicians, or handled in other manners supported by your PACS. After installation, PACS export is automatic and occurs during report printing. CTXA-Hip generates a projection image that has the same appearance as DXA. Exact display of information depends on your PACS system. Features at a glance Export of QCT Pro Spine and/or Hip BMD reports to DICOM destinations. Multiple methods for selecting the destination(s) for a report, including: static list of one or more destinations; selection from a drop-down list; and automatic delivery based on CT scanner ID associated with an analyzed data set PC Specifications: The QCT Pro computer should meet the following recommended minimum specifications: Windows -compatible PC Windows OS CD-ROM drive USB Port 512 MB RAM 80 GB Hard Drive Video 1024 x 768 16-bit color Ethernet adapter 9

CliniQCT from Mindways is also available through distributors in these countries: China Beijing Everbright Success Technology Co. Ltd www.qct8.com Australia MINDWAYS AUSTRALIA www.mindwaysaustralia.com.au Japan TORECK Co. Ltd. www.toreck.co.jp Poland ALSTOR Sp.j. www.alstor.com.pl Italy EUKON srl www.eukon.it Middle East & Lebanon CreoMedic S.A.R.L www.creomedic.com Korea CMP Trading Co. Ltd www.cmptrading.co.kr Turkey imedit Tıbbi Görüntüleme Cihazları & Sis. Ltd. www.imedit.com Mexico Telecomunicacion Y Equipos, S.A. De C.V. South Africa TECMED Africa www.tecmedafrica.com 10

US Offices Mindways Software, Inc. 3001 S Lamar Blvd, Suite 302 Austin, TX 78704, USA Connect with Mindways on Social Media European Offices Mindways Software Inc. Am Germaniahafen 1 24143 Kiel, Germany 0499 www.qct.com DESIGN BY Telephone Toll-free: 877-MINDWAYS Office: +1 512 912-0871 Fax: +1 512 912-0872 European office & support: Tel: +49 (0) 172 30 44 26 7 Support & general inquiries: info@qct.com support@qct.com CliniQCT is an optional module that provides additional asynchronous calibration functionality to the Mindways QCT Pro Bone Mineral Densitometry System