V-VAS ORTHOSIS: A NEW CONCEPT IN UNLOADER KNEE ORTHOSIS DESIGN

Similar documents
Preliminary Outcome Using a New Free Motion Offloading KAFO for Postoperative Management of Hemiepiphysiodesis in Adolescent Tibia Vara

A NEW CONCEPT IN FUNCTIONAL ORTHOSES

by Fillauer LLC US Patent: No. 6,540,709.B1 European Patent: No Swedish Patent: No German Patent: No.

OBJECTIVES. Lower Limb Orthoses to Enhance Ambulation. Role of Orthoses in the Rehabilitation Process OBJECTIVES 3/3/2015

Bledsoe Extender Brace Application Instructions CP Rev D 03/07

Application of Cast Brace for Post Acute Care of Lower Extremity Fractures

CONTRIBUTING SURGEON. Barry Waldman, MD Director, Center for Joint Preservation and Replacement Sinai Hospital of Baltimore Baltimore, MD

The KineSpring Knee Implant System Product Information

A Single-Bar Above-Knee Orthosis

ChiroCredit.com Presents Biomechanics: Focus on

Multiapical Deformities p. 97 Osteotomy Concepts and Frontal Plane Realignment p. 99 Angulation Correction Axis (ACA) p. 99 Bisector Lines p.

Revolution. Unicompartmental Knee System

Reduction of Medial Compartment Loads with Valgus Bracing of the Osteoarthritic Knee

Knee Surgical Technique

Orthotic Correction of Blount's Disease

ORTHOTIC REFERENCE GUIDE. srtprosthetics.com

Product Line Overview. Product Review Pro Knee OA Pro Knee Pro Ankle Pro Wrist Pro Elbow Pro Back 6/4/2018 0

The nomenclature describing the orthosis is basically the same as that suggested for the molded ankle-foot orthosis (2), but the anterior shank enclos

Technique Manual Technique Manual Rev. A 01/11/2011

Bracing for Acute Injury, Functional Activity, and Osteoarthritis of the Knee

Fig. 1. Lateral view of the patient showing stockinet in place and indelible pencil marks indicating areas where modification of the positive model wi

Noble Hinge Technology CHANGING THE FOUNDATION OF SPINAL BRACING

soe strong OA Bracing2011

Literature Review. Nilay Barde

Making the Negative Cast

OrthoMap Express Knee Product Guide. OrthoMap Express Knee Navigation Software 2.0

ORTHOTIC REFERENCE GUIDE. srtprosthetics.com

Distal Cut First Femoral Preparation

Orthotics Measurement Board for Tibial Torsion and Toe-Out

PLAY PLAY. Hard. Smart. Knee Product Guide

PIN GUIDE SYSTEM SURGICAL TECHNIQUE. with the SIGMA High Performance Instruments System. This publication is not intended for distribution in the USA.

BIOMECHANICAL EXAMINATION OF THE PEDIATRIC LOWER EXTREMITY

Proceedings of the World Small Animal Veterinary Association Sydney, Australia 2007

LAMINA SPREADER SURGICAL TECHNIQUE

Original Policy Date

soe tough TRAINERSGUIDE2012

The DM Systems Family of Wound Care Products. Wound Care

BOW LEGS (GENU VARUM)

Extramedullary Tibial Preparation

Fig. 1. Antero-medial view of the knee cylinder. Fig. 2. Lateral view of the knee cylinder. thought of as for asuprapatellar/supracondylar PTB prosthe

, MD. physiologic. tibia varum. in utero (in. Disease in. variation. positioning. back and legs. instead of. Blount's. Infant with bowing in both legs

medi softbraces Now equipped with medi Airtex + - the "Plus" for compression and comfort in wear. medi. ich fühl mich besser.

Instructional Course Lecture 2011

CASE REPORT. Antegrade tibia lengthening with the PRECICE Limb Lengthening technology

TRUMATCH PERSONALIZED SOLUTIONS with the SIGMA High Performance Instruments

Jack PCL. Posterior Cruciate Ligament Brace

Gentle Guided Growth to Correct Knock Knees and Bowed Legs in Children

The effect of knee orthoses on gait parameters in medial knee compartment osteoarthritis: A literature review

2017 Resident Advanced Trauma Techniques Course COMPLICATIONS / CHALLENGES MALUNIONS/DEFORMITY

Periarticular knee osteotomy

Life. Uncompromised. The KineSpring Knee Implant System Surgeon Handout

A One-Piece Laminated Knee Locking Short Leg Brace* by

Orlando Lite HKAFO/KAFO (Custom-to-Measurement only)

Stretch Beyond Your Expectations.

Abramsohn Retractor 1

Shoulder. 36 Shoulder medi orthopaedics

Degenerative knee disorders. Management of knee pain An Orthotists perspective

Managing Tibialis Posterior Tendon Injuries

Kinematic vs. mechanical alignment: What is the difference?

Biomechanics of the Knee. Valerie Nuñez SpR Frimley Park Hospital

Where Is the Natural Internal-External Rotation Axis of the Tibia?

erhem Thoracal spine section Elastic shoulder brace with support bracing Application:

Indications. Arthroscopic hip procedures. Labral repair, with or without gluteus medius repair. Post-op proximal hamstring repair

A New Benchmark in Tibial Fixation

BIOMECHANICAL EXAMINATION OF THE PEDIATRIC LOWER EXTREMITY 2017

Intramedullary Tibial Preparation

Among the non-operative methods, serial or wedge casting of the patient's arm in forced extension has been used with success. However, the weight and

Patellofemoral Instability

Masterclass. Tips and tricks for a successful outcome. E. Verhaven, M. Thaeter. September 15th, 2012, Brussels

ACL RECONSTRUCTION HAMSTRING METHOD. Presents ACL RECONSTRUCTION HAMSTRING METHOD. Multimedia Health Education

Mr Aslam Mohammed FRCS, FRCS (Orth) Consultant Orthopaedic Surgeon Specialising in Lower Limb Arthroplasty and Sports Injury

Using Biomechanical Principles in the Management of Complex Postural Deviations in Sitting

Knee Joint Anatomy 101

Dynamic Stabilization of the Patellofemoral Joint: Stabilization from above & below

Knee Injury Assessment

Biomechanics and Its Application to Seating

a ToeOFF Family Product Single Patient Use

Product Information & Procedure Wall Chart

You can.go on. New line of orthosis for sports. New line of orthosis for sports

DIFFICULT PRIMARY TKA: VALGUS KNEE

VARIABILITY OF THE POSTERIOR CONDYLAR ANGLE

Load Response of the Hindfoot Bones in patients with the Ankle Osteoarthritis : in vivo 3D study

OrthOsis solution Guide

Rotaglide+ TM. Total Knee System Product overview

A Patient s Guide to Adult-Acquired Flatfoot Deformity

Hip and Knee Pain What are my options?

Do Persons with PFP. PFJ Loading? Biomechanical Factors Contributing to Patellomoral Pain: The Dynamic Q Angle. Patellofemoral Pain: A Critical Review

Fractures of the tibia shaft treated with locked intramedullary nail Retrospective clinical and radiographic assesment

taken for a patellar-tendon-bearing socket. After these have partly dried, the balance of the shin is wrapped with a roll of plaster bandage. When the

Genu Direxa Knee Orthoses

Lower Limb Biomechanical Examination

.org. Tibia (Shinbone) Shaft Fractures. Anatomy. Types of Tibial Shaft Fractures

PediLoc Tibia Surgical Technique

TOTAL KNEE ARTHROPLASTY (TKA)

Surgical Technique. VISIONAIRE FastPak Instruments for the LEGION Total Knee System

Correction of Traumatic Ankle Valgus and Procurvatum using the Taylor Spatial Frame: A Case Report

Discrepancies in Knee Joint Moments Using Common Anatomical Frames Defined by Different Palpable Landmarks

Case Study: Christopher

Understanding treatments for knee pain.

ANATOMIC. Navigated Surgical Technique 4 in 1 TO.G.GB.016/1.0

Transcription:

V-VAS ORTHOSIS: A NEW CONCEPT IN UNLOADER KNEE ORTHOSIS DESIGN Joseph W. Whiteside CO/LO 1399 E. Western Reserve Road, Poland, OH 44514-3250 (800) 837-3888 www.anatomicalconceptsinc.com Page 1 of 5

The use of custom or off-the-shelf unloader knee orthoses in both single and double upright design configurations have been successfully used in the management of patients with medial compartment osteoarthritis of the knee. The mechanism to achieve this is a three point pressure system that creates the offloading of the affected compartment. How this offloading is achieved, is through a fixed or an adjustable structural frame being used as a counterforce to an adjustable strap(s) and/or an adjustable condylar pad that act as a corrective force. In more recent designs, a lengthening adjustment has been added to the proximal upright that allows for an angular shifting of the forces to create the offloading affect. Studies have shown that the offloading forces exerted by these devices are successful in relieving pain in those patients with uni compartmental osteoarthritis during weight-bearing activities. Although these designs have been successful, many times there is a certain degree of intolerance to the unloader knee orthosis that is experienced by the patient. This intolerance is typically due to a higher concentration of pressures being exerted by the strap or condylar pad, which can limit duration of use. As offloading adjustments are being made in the double upright designs, the frame configurations of the unloader orthosis do not follow a natural progression as oriented to the long axis of the leg when viewed in the coronal plane. As the corrective forces are applied to obtain the optimal offloading affect, there is an inability to distribute these forces proportionally through the leg. This leads to an inability to better match the center of rotation of the leg as viewed in the coronal plane, which can further limit compliance. In addition, the three points of pressure used in both designs are applied by laterally or medially shifting the femur and/or tibia to offload the affected compartment. This lateral or medial shift causes a certain amount of shear to the mechanical knee joint(s) resulting in a varying degree of binding within the mechanical joint(s). This mechanical binding can further restrict the patients ability to freely flex and extend their knee during various activities of daily living. This shifting of the uprights and binding of the mechanical joint(s) that are felt by the patient can decrease the ability for the patient to comply with a single or double upright unloader knee orthosis. The Varum Valgum adjustable stress (V-Vas Orthosis) 1 custom unloader knee orthosis is a new concept in treating patients who present with medial or lateral compartmental arthropathies. Its custom design incorporates several unique features that increase the effectiveness and compliance for the patient who is in need of an unloader orthosis. Instead of using a narrow frame as seen on most all double and single upright designs it uses a total contact cuff on the thigh and tibia along with a unique adjustable self-aligning polycentric joint system to create four points of pressure instead of three. With two points of pressure being applied as a counter force (located at the proximal and distal ends of the thigh and tibial cuffs on the affected side of the leg) and two points of pressure applied as the corrective force (located at the distal and proximal ends of the thigh and tibial cuffs respectively on the non 1 V-Vas Orthosis is fabricated and distributed by Anatomical Concepts Inc., Poland, OH 44514-3250 Page 2 of 5

affected side of the leg) to offload the affected compartment, there is no need for a condylar pad. As compared to the single upright design, the use of a counterforce strap is not necessary once again, due to the four points of pressure used to create the bending offloading moment. This unique bending offloading moment is reproducible with each application and eliminates the subjectivity of a counterforce strap or condylar pad that are inherent in other designs. Its self-aligning polycentric hinge design, features an efficient and effective means of linearly adjusting the varum or valgum angle (depending on which compartment is affected) without causing mechanical joint binding. This is a very patient and practitioner friendly design due to the mechanical joint allowing for non-mechanical like bending of the knee and never needing re-squared. The V-Vas Orthosis has been very effective in the clinical management of patients with symptomatic medial compartment osteoarthritis. Other successful applications include, lateral compartment osteoarthritis, abnormal genu valgum alignment with up to 30 of semi-flexible deformity non-operative tibial plateau fractures, failed hardware or reconstruction of the tibial plateau, tibial plateau and or femoral condyle spacers and post total knee arthroplasty. The V-Vas Orthosis is currently available in a custom design. The finished design consists of a polypropylene constructed posterior opening thigh and tibial cuff that include a corrugation, to increase transverse plane integrity. The V-Vas Orthosis is secured to the extremity via a Velcro popliteal strap, wrap around thigh and distal tibial cuff straps. The thigh and tibial cuffs are connected via a medial and lateral self-aligning polycentric knee joint. One of the self-aligning joints (placed on the affected side of the leg) has the ability to be lengthened linearly at its proximal and distal ends. The lengthening can be adjusted proportionally or disproportionately proximally (thigh) and/or distally (tibia) to accommodate varying proportions of soft tissue compression. This linear (lengthening) adjustment is achieved via a counter clockwise rotation of the adjustment screw. The opposing self-aligning polycentric joint in the V-Vas Orthosis design is static and functions as a fulcrum to the adjustable self-aligning polycentric joint. This ability to lengthen the upright in a linear motion allows for an anatomically correct varum or valgum bending offloading moment to be applied to the femur and tibia through the soft tissues via the thigh and tibial cuffs respectively. The ability to lengthen the adjustable upright either proportionally or disproportionately is how the optimal bending offloading moment is achieved. The bending offloading moment when adjusted correctly will decelerate or stop the lateral or medial thrust that is associated with knee arthropathy instability. It is the bending offloading moment and the self-aligning joint capabilities that is unique only to the V-Vas Orthosis joint system, leading to improved compliance and pain reduction.. The joint construction consists of a polycentric design that allows for a medial or lateral pivoting motion in the coronal plane. This pivoting motion is achieved through the use of two spherical bearings that are at each axis within the joint head. This design feature not only allows for uninhibited flexion and extension to 180, but an ability to compensate for varying degrees of angulations as viewed in the coronal plane within the joint head. This ability to pivot accommodates the elongation of either the proximal and/ or distal upright, resulting in the self-aligning feature. Page 3 of 5

Figure 1. Shows an increase in the lateral condyle space of 5 or 5mm in a full weight-bearing position while wearing the V-Vas Orthosis offloading custom knee orthosis. Figure 2. Shows the collapsed lateral condyle space in a full weight-bearing position when no orthotic intervention is used. Suspension and anti-migration are accomplished through a removable silicon laden popliteal strap pad, thigh and tibial cuff pads. Recent Case Study: 51 year old male, 5'11" tall and weighing 220 pounds The radiographs of the treated leg showed a 5 or 5 mm improvement in lateral condyle separation while fully weight-bearing, using the V-Vas Orthosis (Figure 1) versus the radiograph of the non-treated leg (Figure 2). This bending offloading moment of the lateral compartment allowed this patient to ambulate with minimal pain while wearing the orthosis. Ultimately, wearing the V-Vas Orthosis allowed the patient to return to the workplace in the same capacity prior to his injury as a flight attendant. There are many design options available to those patients needing offloading knee orthoses. We know from reviewing literature that offloading orthoses are both ethical and very effective. There application will minimize use of medication, delay arthroplasty in the younger patient and control pain in those patients with co-morbidity. They are also used as a pre-operative tool or post operative tool to determine the success of a surgical technique or offloading of the operative compartment respectively. As health care professionals we should strive for optimal outcomes when recommending various designs. Compliance, effectiveness and efficiency in design are all key factors in achieving this optimal result in the current healthcare arena. The unique features in this new design specifically improve compliance and are an efficient and effective alternative used to achieve optimal patient outcomes. Page 4 of 5

References 1. Finger S, Paulos LE. Clinical and Biomechanical Evaluation of the Unloading Brace. Journal of Knee Surgery 2002; 15: 155-159. 2. Pollo FE, Otis JC, Backus SI, Warren RF, Wickiewicz TL. Reduction of Medial Compartment Loads with Valgus Bracing of the Osteoarthritic Knee. The American Journal of Sports Medicine 2002; 30:3: 414-421. 3. Self BP, Greewald RM, Pflaster DS. A Biomechanical Analysis of a Medial Unloading Brace for Osteoarthritis in the Knee. Arthritis Care Research 2000; 13:4: 191-197. 4. Draper ERC, Cable JM, Sanchez-Ballaster J, Hunt N, Robinson JR, Strachan RK. Improvement in function after valgus bracing of the knee. The Journal of Bone and Joint Surgery 2000; 82-B:7: 1001-1005. 5. Giori NJ. Load-shifting brace treatment for osteoarthritis of the knee: A minimum 21 2-year follow-up study. Journal of rehabilitation Research & Development. March/April 2004; 41:2: 187-194. 6. Nadaud MC, Komistek RD, Dennis DA, Anderele MR, Kubo MB. In Vivo Three- Dimensional Determination of OA Brace Effectiveness: A Multiple Brace Analysis from the written material for a lecture delivered at American Academy of Orthopaedic Surgeons 72nd Annual Meeting, 2005. 8 About Joseph W. Whiteside, CO/LO Joseph W. Whiteside CO / LO has over 25 years of experience in the clinical management of patients with knee arthropathies and bowing deformities. He is Clinical Director of Research and Development for Anatomical Concepts Inc. He speaks nationally and internationally on the subject. E-mail him at jwhiteside@ anatomicalconceptsinc.com. About Anatomical Concepts Inc. USA Since 1990, Anatomical Concepts has developed industry-leading medical devices, custom-fit and custom-fabricated orthoses for both upper and lower extremities. Anatomical Concepts Inc. is the manufacturer and distributor of the V-Vas Knee Orthosis (KO) and Knee Ankle Foot Orthosis (KAFO). It is a team of practitioners, designers, and manufacturers utilizing advanced technology to develop superior products that not only deliver effective outcomes, but present ease-of-use for the medical professional. The company is the original concept developer of the PRAFO, or Pressure Relief Ankle Foot Orthosis, used in medical facilities internationally. Anatomical Concepts is headquartered in Poland, OH, and provides medical devices, services, and consulting both nationally and internationally. The company's innovative product line has inspired the procurement of eleven US product patents. Providing solutions for medical professionals and helping to improve patient outcomes is still the driving force behind the corporation. Anatomical Concepts, Inc. products are FDA registered and also carry the CE marking. All products, including the ELLIOTT and ELLIOTT II, are designed, manufactured, and trademarked by Anatomical Concepts, Inc. To learn more about Anatomical Concepts range of products, learning resources, and events, please visit http://www.anatomicalconceptsinc.com or call (800) 837-3888. REVISED 08/24/12 Page 5 of 5