Neurostimulation Systems

Similar documents
Pocket Adaptor Kit FOR SPINAL CORD STIMULATION. Tip Cards

Medtronic, Inc.

Activa RC and Activa PC

Canada Medtronic of Canada Ltd Kitimat Road Mississauga, Ontario L5N 1W3 Canada Tel Fax

NEW JERSEY PAINCONSULTANTS OFFERS PATIENTS FIRST IMPLANTABLE NEUROSTIMULATION SYSTEM WITH MOTION SENSOR TECHNOLOGY FOR THE MANAGEMENT OF CHRONIC PAIN

TAKE CONTROL OF YOUR FUTURE

SYSTEM ELIGIBILITY BATTERY LONGEVITY

BEFORE AND AFTER YOUR MRI SCAN. For patients with St. Jude Medical neurostimulation systems for chronic pain

DRG THERAPY FOR CHRONIC PAIN ACCURATE CLINICAL STUDY FACT SHEET FOR PATIENTS

Tell the doctor who prescribed your MRI scan that you have an implanted Medtronic neurostimulation system.

Resolute Integrity. Independent Conformability Assessment

INL No. A0083 Project Medtronic Thoracic patients guide Description Version 18

PATIENT CONTROLLER ST. JUDE MEDICAL UNDERSTANDING IMPORTANT FEATURES ON YOUR

Out of pain. Into relief.

Proven pain therapy. Stimulating results.

DRG STIMULATION FOR CHRONIC PAIN FOCUS ON YOUR LIFE NOT YOUR PAIN

INL No. A0075 Project Medtronic Patient Information Leaflet Description 16 page booklet

POSTOPERATIVE PATIENT MANAGEMENT

USING YOUR INTELLIS IMPLANTABLE SPINAL CORD STIMULATION SYSTEM

MEDTRONIC CARELINK NETWORK FOR PACEMAKERS. Comparison between the Medtronic CareLink Network for Pacemakers and Transtelephonic Monitoring

Micra MC1VR01. MRI procedural information for Micra Model MC1VR01 MR Conditional single chamber transcatheter pacing device (VVIR)

DRG STIMULATION FOR CHRONIC PAIN FOCUS ON YOUR LIFE NOT YOUR PAIN

DRG STIMULATION INTERVENTIONAL PAIN CENTER

SINGAPORE GUIDED LUMBAR PROCEDURES WORKSHOP ULTRASOUND AND FLUOROSCOPIC OCTOBER 29-30, 2016 ACADEMIA, SINGAPORE GENERAL HOSPITAL PRESENTED BY:

PNS FOR BACK PAIN IMPROVING PATIENT OUTCOMES

Patient Information FOR NEUROSTIMULATION

PARKINSON S SYMPTOM TRACKER

Model 5392 EPG Temporary Pacer

Take control of your pain therapy. Getting started with Algovita SCS.

Advisa MRI and Ensura MRI SureScan pacing systems

Sacral Nerve Stimulation (SNS) System Implantation

USING YOUR IMPLANTED SPINAL CORD STIMULATION SYSTEM

Nevro Reimbursement Support

RestoreSensor Implant manual. Multi-program rechargeable neurostimulator. ! USA Rx only

APY ER TH F10 H UT ABO

InterStim Therapy. symptom diary

Parkinson s disease, Essential Tremor and primary dystonia

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500)

Deep Brain Stimulation (DBS) For patients with tremor

Prodigy Neurostimulation System Programming and Reference. Models 3855, Clinician's Manual

Your guidebook for getting results with Medtronic Bladder Control Therapy Delivered by the NURO System TAKE BACK CONTROL.

Corporate Medical Policy

PAIN LIFE INTER- RUPTED TRANSFORMED BURSTDR STIMULATION FOR CHRONIC PAIN

HF10 THERAPY 2018 Ambulatory Surgery Center Reimbursement and Coding Reference Guide

UNLOCK THE ANSWER. The Reveal LINQ TM System lets your physician learn about your heart while you live your life.

Dr. Guy Buchanan MBBS, FANZCA, FFPMANZCA Specialist Pain Medicine Physician & Anaesthetist Associate - Victoria Pain Specialists

Yes, out of sight out of mind.

DOCTOR DISCUSSION GUIDE

BRAVO. ph Monitoring System. A patient-friendly test for heartburn

2016 HF10 THERAPY REIMBURSEMENT REFERENCE GUIDE

LIVE LIFE WITH LESS PAIN

AT THE FOREFRONT OF MENDING THE BRAIN

Illumina 3D Portfolio

Q & A: How to Safely Scan Patients with a SureScan MRI Pacemaker

Precision TM. Plus. Rechargeable Spinal Cord Stimulation System

Read this manual before performing an MRI scan on a patient implanted with an Algovita Spinal Cord Stimulation System.

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System

Algovita. MRI Procedure Guidelines. Spinal Cord Stimulation System. 201x

Spinal Cord Stimulation. OHTAC Recommendation. Spinal Cord Stimulation for the Management of Neuropathic Pain

2014 AAPM 56 th Annual Meeting

Paddle Lead Kit. Models 3214, 3219, 3224, 3228, 3240, 3243, 3244, 3245, 3246, 3262, 3266, 3268, 3283, 3286, Clinician's Manual

ITREL 3 Neurostimulator

Chronic pain Neurostimulation What is neurostimulation and how does it work? Neurostimulation is a proven, effective, reversible treatment

Mini Pulse Electronic Stimulator

CARDIAC DEVICE MR-CONDITIONAL PRODUCT SUMMARY CHART

Neurostimulation. Spinal cord stimulators use electrodes placed in the space surrounding the spinal cord (epidural space).

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500)

NEED A DEFIBRILLATOR? NOW YOU HAVE OPTIONS.

Medtronic DBS Therapy Implanted neurostimulators

H F 1 0 T H E R A P Y R E I M B U R S E M E N T R E F E R E N C E G U I D E

PAIN INTER- DRG THERAPY FOR CHRONIC PAIN RUPTED LIFE TRANSFORMED

Innovations In Neuromodulation. Maged Guirguis, MD Director Of Research Pain Management

@ Medlronic. PURSUING ADVANCED INDICATIONS: COMPLEX BACK AND LEG PAl N. The Art and Science of Neurostimulation

MRI ACCESS. Evera MRI SureScan ICD Systems

EN/197877_001/ccs 1/29/01 2:18 PM Page 1. Itrel. EZ Model 7434A Patient Programmer. User Manual Rx Only

Percutaneous Lead Kit. Models 3143, 3146, 3149, 3153, 3156, 3159, 3183, 3186, Clinician's Manual

Lead and Extension Insertion Tool. Model Clinician's Manual

WAS ATRIAL FIBRILLATION THE CAUSE OF MY STROKE? Finding answers about cryptogenic stroke

ImageReady MRI Head Only Guidelines for Spectra WaveWriter Spinal Cord Stimulator System

Surgical Lead Implantation Guide

St. Jude Medical 8-Channel Adapter. Clinician's Manual

DRG THERAPY FOR CHRONIC PAIN PAIN INTER- RUPTED LIFE TRANSFORMED

Muscle Stimulation. Page 1

Transcutaneous Electrical Nerve Stimulation Device GF-3 / GF-3T

ImageReady MRI Full Body Guidelines for Precision Montage MRI Spinal Cord Stimulator System

8/28/18. Anesthetic considerations for patients with implanted devices for treating chronic pain and more. Objectives:

PROVEN PLUS. Introducing the Avalus Aortic Valve by Medtronic.

Before Your MRI FOR PATIENTS WITH MEDTRONIC NEUROSTIMULATION SYSTEMS FOR CHRONIC PAIN

See Policy CPT/HCPCS CODE section below for any prior authorization requirements

IS THERE A LINK BETWEEN ATRIAL FIBRILLATION AND MY STROKE? Finding answers about cryptogenic stroke

Leadless pacing. P.E. Vardas Professor of Cardiology University of Crete, Greece

Biomedical Instrumentation

Precision Montage MRI Spinal Cord Stimulator System

MRI guidelines for Medtronic neurostimulation systems for chronic pain

2015 ST. JUDE MEDICAL THERAPY CODING GUIDE Cardiac Pacemakers

The success of any Inter-

Implantable Pulse Generator. Prodigy IPG Prodigy MRI IPG. Clinician's Manual

Spinal Cord Stimulation - Patient Information No 7

2 016 HF10 THERAPY HOSPITAL OUTPATIENT DEPARTMENT AND AMBULATORY SURGERY CENTER REIMBURSEMENT REFERENCE GUIDE

Transcription:

Neurostimulation Systems Expanding the Array of Pain Control Solutions

PROVEN EFFECTIVE FOR SIMPLE PAIN ITREL 3 SYSTEM For simple neuropathic pain Totally implantable for enhanced quality of life Easy to use for both physicians and patients SYNERGY SINGLE LEAD SYSTEM Synergy Neurostimulation System Model 7729 Pisces-Quad Compact Lead Model 3887 IPG Plug (Socket II) Model 3550-09 ITREL 3 SINGLE LEAD SYSTEM Itrel 3 Neurostimulator Model 7425 Itrel EZ Patient Programmer Model 7434 Pisces-Quad Compact Lead Model 3887 SYNERGY TM SINGLE LEAD SYSTEM Increased longevity for fewer surgical replacements Flexibility to adapt to a dual lead system if disease progression is expected Programmable Day Cycler mode conserves energy for greater battery longevity Longevity (months) 300 250 200 150 100 50 Synergy Itrel 3 SINGLE LEAD APPLICATION DEVICE LONGEVITY* The Synergy implantable pulse generator (IPG), when used as part of a single lead system, will last approximately twice as long as an Itrel 3 IPG at moderate voltage settings. At higher voltage settings, the Synergy IPG will last at least 50% longer than an Itrel 3 IPG. *Longevity modeling calculations compare battery longevities of a Synergy single lead system and an Itrel 3 single lead system where both devices are programmed at 240 µsec, 30 Hz with 2 active electrodes. 0 1 2 3 4 5 6 7 8 9 10 Volts PUTTING PAIN CONTROL IN YOUR PATIENTS HANDS Allows patients to fine-tune amplitude, pulse width, and rate for optimal pain relief Convenient and easy to use Itrel EZ Patient Programmer Model 7434 Synergy EZ Patient Programmer Model 7435

SYNERGY SYSTEM: POWER AND FLEXIBILITY TO TREAT COMPLEX BACK AND LEG PAIN Total implantability for patient quality of life Access to 8 electrodes per channel Alternating pulses on 2 independent channels EZ patient control of stimulation Transverse stimulation offers more options for targeting of required stimulation sites SYNERGY DUAL CHANNEL SYSTEM Synergy Neurostimulation System Model 7729 Pisces-Quad Compact Leads Model 3887 Channel 1 Channel 2 MATTRIX SYSTEM: ADDED POWER For patients with high power requirements Access to 4 electrodes per channel Alternating pulses on 2 independent quadripolar arrays MATTRIX DUAL CHANNEL SYSTEM Mattrix Receiver Model 3272 Mattrix Transmitter Model 3210 Specify Surgical Lead Model 3998 Longevity (months) 250 200 150 100 50 0 1 2 Synergy Itrel 3 3 4 5 6 7 8 9 10 Volts SYNERGY DUAL CHANNEL AND ITREL 3 SINGLE LEAD DEVICE LONGEVITY* The Synergy implantable pulse generator (IPG), when used as part of a dual channel system, will last approximately as long as an Itrel 3 IPG with a single lead. At lower voltages, the Synergy IPG longevity is significantly greater than that of the Itrel 3. *Longevity modeling calculations compare battery longevities of an Itrel 3 single lead system to a Synergy dual channel system where all leads/channels are programmed at 240 µsec, 30 Hz with 2 active electrodes per lead/channel.

SOLUTIONS FOR DIVERSE PATIENT NEEDS PERCUTANEOUS LEADS Optimal steerability with Medtronic s coiled wire design and removable center stylet. Pisces-Quad Compact Lead For a more precise, focused field Lead electrodes 3 mm long, 4 mm spacing Electrode span 24 mm Pisces-Quad Lead Lead electrodes 3 mm long, 6 mm spacing Electrode span 30 mm Pisces-Quad Plus Lead Lead electrodes 6 mm long, 12 mm spacing Electrode span 60 mm SURGICAL LEADS For patients who can benefit from increased lead stability. Percutaneous Leads Top to Bottom: Pisces-Quad Compact Model 3887 Lead Pisces-Quad Model 3487a Lead Pisces-Quad Plus Model 3888 Lead Resume II Lead The most requested surgical lead on the market Lead paddle 8 mm wide, 2 mm thick Resume TL Lead For smaller epidural spaces Lead paddle 6.6 mm wide, 1.4 mm thick On-Point PNS Lead For single-nerve-distribution pain Anchorable mesh skirt surrounding paddle Lead paddle 6.6 mm wide, 1.4 mm thick Specify TM Lead Ability to increase specificity of paresthesia patterns Lead paddle 7.9 mm wide, 1.8 mm thick Especially for use with Synergy and Mattrix Systems FOR BROADER COVERAGE Dual 4 TM Extension Converts single lead systems to allow broader coverage of pain Compatible with all of Medtronic s in-line leads Surgical Leads Top to Bottom: Resume II Model 3587a Lead Resume TL Model 3986 Lead On-Point Model 3987 Lead Specify Model 3998 Lead Dual4 Extensions Model 7498 Specify Surgical Lead Model 3998 Two Pisces-Quad Compact Model 3887 Leads

EXPANDING YOUR OPTIONS FOR PAIN CONTROL For more than 30 years, Medtronic has been a pioneer in the development of neurostimulation systems for neuropathic pain. This therapy has offered hope to thousands of people with chronic intractable pain. Now, Medtronic has expanded its array of products to include the world s only totally implantable neurostimulation system for complex back and leg pain the Synergy TM Neurostimulation System. SYNERGY TM NEUROSTIMULATION SYSTEM: Adaptability use as a single lead system or as a dual channel system Flexibility transverse stimulation between the leads increases options to direct stimulation to where it s needed Longevity increased battery capacity for more demanding applications SYNERGY NEUROSTIMULATION SYSTEM MODEL 7729 Synergy IPG Model 7427 Synergy EZ Model 7435 Giancarlo Barolat, MD Thomas Jefferson University Hospital, Department of Neurosurgery The Synergy System will offer an advantage for the pain practitioner when treating patients with complex back and leg pain. Part of the frustration of using neurostimulation in these patients has been the inability to direct the stimulation to where the pain is. Dual channels will allow us to better tailor the stimulation so that we can capture both the low back and lower extremity pain. With this totally implantable system, we now have something that may help patients who could not be helped previously.

SYNERGY NEUROSTIMULATION SYSTEM POWER AND FLEXIBILITY Learn more about how Medtronic neurostimulation systems provide additional solutions for treating complex back and leg pain. For more information, contact your therapy consultant directly or call 1-800-664-5111, ext. 470, to receive an informational packet. Or, you can visit us at www.medtronicsynergy.com. VALUE-ADDED SERVICES ONLY FROM MEDTRONIC Every neurostimulation product from Medtronic is supported by a comprehensive range of services including: On-site Training Program 24-hour technical support Reimbursement and Clinical Education Specialist support Training and educational materials and workshops Patient services Therapy Access Consulting BRIEF SUMMARY: Product technical manual must be reviewed prior to use for detailed disclosure. INDICATIONS: The Medtronic Synergy, Medtronic Itrel, and Mattrix Neurostimulation Systems are indicated to aid in the management of chronic, intractable pain of the trunk or limbs. The Mattrix Receiver Model 3272 system is also indicated for peripheral nerve stimulation. CONTRAINDICATIONS: Unsuccessful pain relief during trial stimulation of the spinal cord, or inability of patients to properly operate the system. The Mattrix system is contraindicated for patients with an implantable cardiac pacemaker or cardioverter/defibrillator, or for those patients who will be exposed to magnetic resonance imaging (MRI). WARNINGS/PRECAUTIONS/ADVERSE EVENTS: Safety has not been established for pregnancy or pediatric use. Patients should not drive or use dangerous equipment during stimulation. Systems may be affected by or adversely affect cardiac pacemakers, cardioverter/defibrillators, external defibrillators, MRI, diathermy, ultrasonic equipment, electrocautery, radiation therapy, theft detectors, security systems, and aircraft communications systems. Adverse events may include: undesirable change in stimulation described by some patients as uncomfortable, jolting or shocking, hematoma, epidural hemorrhage, paralysis, seroma, CSF leakage, infection, erosion, allergic response, hardware malfunction or migration, pain at implant site, loss of pain relief, chest wall stimulation, and surgical risks. Patient selection criteria include physiological origin for the pain, appropriate surgical candidate, detoxification from narcotics, and availability of long-term post-surgical management. CAUTION: U.S. federal law restricts this device to sale and use by or on the order of a physician. United States of America Medtronic Neurological 800 53rd Avenue NE Minneapolis, MN 55421-1200 USA Internet: www.medtronic.com Telephone: (612) 514-5000 FAX: (612) 514-5078 Toll-free: 1-800-328-0810 Europe Medtronic Europe S.A. Route du Molliau CH-1131 Tolochenaz Switzerland Internet: www.medtronic.co.uk Telephone: (41 21) 802 7000 FAX: (41 21) 802 7900 Asia-Pacific Medtronic International, Ltd. Suite 1602 16/F. Manulife Plaza The Lee Gardens, 33 Hysan Avenue Causeway Bay Hong Kong Telephone: (852) 2891 4068 FAX: (852) 2591 0313 Australia Medtronic Australasia Pty. Ltd. 50 Strathallen Avenue Northbridge NSW 2063 Australia Telephone: (61 2) 9958 2999 FAX: (61 2) 9958 7077 Toll-free: 1-800-251760 Canada Medtronic of Canada Ltd. 6733 Kitimat Road Mississauga, Ontario L5N 1W3 Canada Telephone: (905) 826-6020 FAX: (905) 826-6620 Toll-free: 1-800-268-5346 Latin America Medtronic, Inc. 600 West Hillsboro Blvd. Hillsboro Center, Suite 500 Deerfield Beach, FL 33441 USA Telephone: (954) 428-8556 FAX: (954) 428-8984 Visit us at www.medtronicpain.com UC199901189EN NI-3764EN Medtronic, Inc. 1999 All Rights Reserved Printed in USA