NEWBORN EXPANDED SCREENING NEXT GENERATION. NeoBase 2 Non-derivatized MSMS kit

Similar documents
LSD EASY AND EFFICIENT SCREENING. NeoLSD MSMS kit

Reliable. results. efficiently. for CH, galactosemia, CAH and CF screening

Xiaolei Xie, Marta Kozak. Thermo Fisher Scientific, 355 River Oaks Parkway, San Jose, CA Introduction

Neonatal Screening using Shimadzu LCMS- 8040

Neonatal Screening using Shimadzu LCMS-8040

Newborn Screening by Tandem

Analytes, instrumentation and software for neonatal screening. Complete solutions for screening newborns

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual

Use of a Tandem Mass Spectrometry Research Method for the Analysis of Amino Acids and Acylcarnitines in Dried Blood Spots

AbsoluteIDQ Kit: Targeted Metabolomics Identification and Quantification

An Introduction to the Use of itraq Reagents for Amino Acid Analysis

Acylcarnitine Analysis using the Perkin Elmer Neobase Kit. Katherine Wright Alder Hey, Liverpool

Manual. Transfer step. Figure 1. Workflow comparison of manual phenylalanine assay and automated GSP Neonatal Phenylalanine assay

AbsoluteIDQ p150 Kit. Targeted Metabolite Identifi cation and Quantifi cation. Bringing our targeted metabolomics expertise to your lab.

Mass Spectrometry Made Simple for Clinical Diagnostic Labs

For Research Use Only

MS/MS APPROACHES TO CLINICAL TESTING FOR INBORN ERRORS OF METABOLISM

AbsoluteIDQ p180 Kit. Targeted Metabolite Identifi cation and Quantifi cation

Adenosine deaminase severe combined immunodeficiency (ADA-SCID)

Short Term Follow Up Tandem Mass Spectrometry Workshop Agenda

Attachment 1. Newborn Screening Program Description

NEONATAL TSH Screening ELISA. Cat. No.: MSUD Screening Assay Screening assay for the detection of Maple Sirup Urine Disease in Newborns

Simultaneous Analysis of Amino Acids and Acylcarnitines in Dried Blood Spots

PKU (Phenylketonuria) Serum LC-MS/MS Analysis Kit User Manual

Determination of Unbound Urinary Amino Acids Incorporated with Creatinine Normalization by LC-MS/MS Method with CLAM-2000 Online Sample Pre-treatment

Utilizing AlphaLISA Technology to Screen for Inhibitors of the CTLA-4 Immune Checkpoint

NEWBORN METABOLIC SCREEN, MINNESOTA

ab HRV 3C Protease Inhibitor Screening Kit (Colorimetric)

Analysis of Common Sweeteners and Additives in Beverages with the PerkinElmer Flexar FX-15 System Equipped with a PDA Detector

HA Convention 2016 Master course How to Handle Abnormal Newborn Metabolic Screening Results Causes, Management and Follow up

LAB#23: Biochemical Evidence of Evolution Name: Period Date :

AlphaScreen TNFα Binding Assay Kit: A Homogeneous, Sensitive and High-Throughput Assay for Screening TNFα Receptors

Analysis of FAMEs Using Cold EI GC/MS for Enhanced Molecular Ion Selectivity

Quantitative LC-MS/MS Analysis of Glucagon. Veniamin Lapko, Ph.D June 21, 2011

Mary Seeterlin, PhD Michigan Department of Community Health. Prevent Disease Promote Wellness Improve Quality of Life

Disorder name: Severe Combined Immunodeficiency Acronym: SCID

For Your Baby s Health Department of Health

Practical relevance of measurement uncertainty in inborn errors of metabolism. Prof Jim Bonham Clinical Director Sheffield Children s NHS FT

FRAGILE X MOLECULAR DIAGNOSTICS ORDERING INFORMATION. FragilEaseTM FRAGILEASETM ASSAY CHARACTERISTICS WORKFLOW. PCR Purification.

Annexin V APC Assay Kit

Quality Management System Certification. Understanding Quality Management System (QMS) certification

Prediction and Prevention of Type 1 Diabetes

PKU (Phenylketonuria) Serum HPLC Analysis Kit User Manual

Analysis of L- and D-Amino Acids Using UPLC Yuta Mutaguchi 1 and Toshihisa Ohshima 2*

MS/MS Standards. Enriching Scientific Discovery

Chapter 26. Newborn Screening

MALDI Sepsityper Kit

HLA DRA (alpha chain) and LAG-3 (Human) Binding AlphaLISA Kit

Operating Instructions

Newborn screening for congenital metabolic diseases Optional out-of-pocket tests Information Sheet

Human Immunodeficiency Virus type-1 p24 protein (HIV p24) Kit

Influenza A NP AlphaLISA Detection Kit

SIMPLE BASIC METABOLISM

AlphaScreen Nickel Chelate Donor Beads at 5 mg/ml in 25 mm Hepes, ph 7.4, 100 mm

How-To Evaluate a Veterinary Digital Radiography System A SPECIAL REPORT

Combined Newborn Screening for Succinylacetone, Amino Acids, and Acylcarnitines in Dried Blood Spots

cobas u 601 urine analyzer Providing precise and secure test results

Captus 3000 Thyroid Uptake And Well System The Ultimate... User Friendly... Intuitive

Objective: You will be able to explain how the subcomponents of

Protein Investigator. Protein Investigator - 3

Amino Acid Disorders. Disorder name: Tyrosinemia, type 1. What is tyrosinemia 1? Genetic Fact Sheets for Parents

X-ALD Newborn Screening and Follow-up testing in USA

Rapid Alcohol Screening Devices. p19

2013 Clinical drug and alcohol testing solutions. Product Catalog. CLIA-waived point of care test devices

Hepatitis B Virus Surface antigen (HBsAg) AlphaLISA Detection Kit

THE COMPLEX JOURNEY OF A VACCINE PART I The manufacturing chain, regulatory requirements and vaccine availability

The Many Lives of the Newborn Screening Dried Blood Spot (the LIFE CYCLE of a Blood Spot)

BASIC SCIENCES & BIOCHEMISTRY FOR BETZPAENIC BRIMBLERS

Branched Chain Amino Acid Assay Kit

02006B 1 vial 02006B 1 vial Store at -20 C. Lyophilized recombinant IL-2

Human C-C Motif Chemokine 5 / Regulated Upon Activation Normal T-cell Expressed and Secreted (CCL5 / RANTES) Kit

Mouse / Rat Connecting Peptide (m / r C-Peptide) Kit

Biological systems interact, and these systems and their interactions possess complex properties. STOP at enduring understanding 4A

S-01 SUPPORTING INFORMATION. TITLE: Inter-laboratory reproducibility of a targeted metabolomics platform for analysis of human serum and plasma

Gentian Canine CRP Immunoassay Application Note for scil VitroVet*

ab HIV-1 Protease Inhibitor Screening Kit (Fluorometric)

Workflow for Screening and Quantification of the SAMHSA (NIDA) Panel in Urine Using UHPLC-TOF

Human Glucagon-Like Peptide-1 (7-36 amide) (GLP-1 (7-36 amide)) Kit

DELFIA Tb-N1 DTA Chelate & Terbium Standard

Classification of amino acids: -

Protein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates

LC/MS/MS SOLUTIONS FOR LIPIDOMICS. Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS

AVENIO family of NGS oncology assays ctdna and Tumor Tissue Analysis Kits

LIAISON QuantiFERON -TB Gold Plus Solution

Competitor Series. Body Composition Analyzers

NEW! KIBION DYNAMIC 13 C BREATH TEST ANALYSER. Rapid and reliable diagnosis of Helicobacter pylori infections

LC-MS/MS for the quantification of Peptide biomarker and mixture of closely related Protein in formulation

A Definitive Lipidomics Workflow for Human Plasma Utilizing Off-line Enrichment and Class Specific Separation of Phospholipids

Mercodia Glucagon ELISA

Auto-absorbance of fish extract and co-factors. IMP + Hx + Ino. Absorbance Blank. Absorbance Blank

Human TRPC6 Ion Channel Cell Line

Perform extraction for finished product, rinse water or swab. Transfer 12 drops of extract to incubation vial.

ab HMG-CoA Reductase Activity Assay Kit (Colorimetric)

Fatty Acid Mass Spectrometry Protocol Updated 10/11/2007 By Daren Stephens

SCIEX Vitamin D 200M Assay for the Topaz System

Branched Chain Amino Acid (Leu, Ile, Val) Assay Kit

CTLA-4 (Human) AlphaLISA Detection Kit

PKU PKU. Phenylketonuria TEMPLE. Information for families following Information for families after a positive newborn screening

Transcription:

NEXT GENERATION EXPANDED NEWBORN SCREENING NeoBase Non-derivatized MSMS kit The next generation NeoBase Non-derivatized MSMS kit gives you the ability to screen for all the common amino acid, organic acid and fatty acid oxidation disorders as well as purine and peroxisomal metabolic disorders. NeoBase MSMS kit may not be available in all countries, such as Canada and US. Please check out availability with your local PerkinElmer representative

COMMITED TO GIVING BABIES A BETTER CHANCE AT LIFE NEOBASE KIT, THE NEXT GENERATION IN MSMS BASED NEWBORN SCREENING PerkinElmer, a pioneer and the global leader in mass spectrometry based newborn screening since 00, currently offers the NeoBase Non-derivatized MSMS Kit, the gold standard in mass spectrometry based testing for amino acid, organic acid, and fatty acid oxidation disorders, used to screen for millions of babies annually. While the NeoBase kit has serviced the industry well, we have collected feedback from customers over the last decade to determine how we can make it easier for labs to test for more disorders, with less resources, while reducing their false positive rate. Based upon requests to be able to screen for more disorders in less time from a single punch in a simple three step workflow, we are proud to be developing the NeoBase kit, the next generation non-derivatized MSMS kit, the efficient and cost-effective way to expand newborn screening without the need for additional equipment and resources. WHY CHOOSE NEOBASE FOR EXPANDED SCREENING? Test for up to 57 analytes, including markers for screening of X-ALD and ADA SCID, from a single DBS punch with a single extraction and incubation step DBS quality controls with analyte concentrations adjusted at clinically significant levels Shorter extraction time, shorter incubation time and shorter run time 940 Winter Street Wallac Oy Waltham, MA 0451 USA PO Box 10 Phone: (800) 76-4000 or 0101 Turku, Finland (+1) 03-95-460 Phone: + 358 678 111 www.perkinelmer.com Fax: + 358 678 357 ISO 485 ISO 9001 CMDCAS ISO 14001 OHSAS 18001 A reformulated Flow Solvent that improves ionization and makes it easy to switch between the NeoLSD kit and NeoBase kit All internal standards are in a single vial making reconstitution easy. Extraction solution is stable for up to two weeks, eliminating the need for daily preparation. New specific markers for Urea Cycle Disorders ASA-LD, OTCD, CPS-I and NAGS as well as for ADA SCID providing more conclusive screening results For a complete listing of our global offices, visit www.perkinelmer.com/contactus 01 All rights reserved. PerkinElmer is a registered trademark of All other trademarks depicted are the property of their respective holders or owners. PerkinElmer reserves the right to change this document at any time and disclaims liability for editorial, pictorial or typographical errors. 144-9841-04, July 01

FASTER AND SIMPLER ASSAY WORKFLOW KIT INCLUDES ALL COMPONENTS YOU NEED FOR EFFECTIVE NEWBORN SCREENING 0 U-bottomed microplates ANSI-standard U-bottomed microplates 0 sheets of adhesive microplate covers Easy-to-use adhesive covers for all assay steps NeoBase Nonderivatized Assay Solution The package includes a bottle of each of extraction solution and flow solvent. One package is enough for two NeoBase Non-derivatized MSMS kits. NeoBase internal standards All 30 internal standards provided in a single vial Controls Kit controls, Low and High. Three filter paper cassettes containing 3 spots of each Lot specific quality control certificate The exact concentrations of isotope labeled internal standards measured by the manufacturer are given on the lot-specific quality control certificate included in the kit NeoBase Succinylacetone Assay Solution optional reagent for the detection of succinylacetone when screening for tyrosinemia type I is desired ALL INTERNAL STANDARDS IN ONE VIAL EXTRACTION WORKING SOLUTION STABLE FOR UP TO TWO WEEKS EXTRACTION TIME REDUCED TO ONLY 30 MIN SA INCUBATION TIME REDUCED TO ONLY 1 HOUR REDUCED SAMPLE TO SAMPLE RUN TIME MSMS Internal standard vial reconstitute in 1.4mL of extraction solution Extraction Working Solution (EWS) IS (dilute 1:100) and Succinylacetone assay solution (dilute 1:50) with the extraction solution Punch out controls and samples into 96-well plate Add 15 μl EWS in each well Cover plate with adhesive aluminum covers DBS extraction / shake for 30 minutes Transfer 100 µl to a new 96-well microplate Cover plate and let stand for 1 hour (required only if testing for SUAC) Load plate on auto sampler and measure

MORE S, IMPROVED PERFORMANCE, BETTER PRODUCTIVITY IMPROVED FOR EVEN BETTER EXPANDED SCREENING Main new features compared to the NeoBase Non-derivatized kit are: Table 1. Analytes measured by the NeoBase Non-derivatized MSMS Kit and their corresponding internal standards and controls. AMINO ACIDS CARNITINES 14 new analytes: 3 amino acids (ASA,Glu, ), 5 acylcarnitines (:OH, C0- C6), 4 lysophospholipids (LPC0:0-LPC6:0), nucleosides (Ado, dado) New single all-in-1 Internal Standards (30) vial: Easier preparation and improved extraction working solution stability ( weeks instead of 1 day) Ala Arg Asa* Cit Glu Gly Leu/Ile/Pro-OH Met Orn Phe Pro Tyr Val -Ala H 4, C-Arg H 4, C-Arg H -Cit - - 15 N,- C-Gly -Leu -Met H 6 -Orn C 6 -Phe -Pro C 6 -Tyr 15 N- -Val Ala Arg Asa Cit Gly Leu Met Orn Phe *Asa is measured as a total concentration of Asa and its anhydrides. KETONES SA -MPP** Pro Tyr Val ** Stable-isotope labeled succinylacetone (SA) derivative 3-(5-methyl-1H-pyrazol-3-yl) propanoic acid (MPP). NUCLEOSIDES d PHOSPHOLIPIDS C0:0 LPC C:0 LPC :0 LPC C6:0 LPC - -d H4-C6:0 LPC H4-C6:0 LPC H4-C6:0 LPC H4-C6:0 LPC SA C6:0 LPC C6:0 LPC C6:0 LPC C6:0 LPC C0 C C3 C3DC/OH DC/OH :1 DC/C6OH C6 C6DC :1 :1 : C1 C1:1 :1 : OH :1 OH :1OH :1 : OH :1OH :OH C0 C C6 H9-C0 H3-C H3-C3 H3- H3- H9- H9- H9- H6-DC H3-C6 H6-DC H3- H3- H3- H3- H3- H3-C1 H3-C1 H3- H3- H3- H3- H3- H3- H3- H3- H3- H3- H3- H3- H3- H3- H3-C6 H3-C6 H3-C6 H3-C6 C0 C C3 DC C6 DC C1 C1 C6 C6 C6 C6 New kit controls (30) with optimized levels (Low, High) New single ANSI-standard plate and easy-to-use adhesive plate cover for all assay steps Non-derivatized Assay Solutions: New high quality borosilicate glass bottles, new Flow Solvent with lower MSMS background Succinylacetone Assay Solution: Faster succinylacetone (SA) extraction step with 60 min shorter waiting time OPTIONAL: MSMS WORKSTATION SOFTWARE Complete new software for managing,reviewing and reporting results Import data from instrument software - Concentrations, IS intensties and TIC raw data Visualize results - Plate map with colored wells - Flagging of wells violating cutoffs or other QC criteria - View TIC & spectra - View results by disorder - Split grid view for easy review of results SQL server database to store and consolidate data from one or more MSMS instruments Perform QC trend analysis and reporting Sample and assay audit tracking Automatic export to R4S for analysis Export results to LIMS

COMPLETE MASS SPECTROMETRY SOLUTIONS FOR NEWBORN SCREENING. A COMMUNITY OF SUPPORT From dried blood spot cards, punchers, instruments, reagents to informatics, PerkinElmer's mass spectrometry solutions empower newborn screening laboratories across the globe to meet their demands. By joining the PerkinElmer newborn screening community, you become part of a movement that includes the majority of the newborn screening laboratories and leaders worldwide. In addition to all necessary equipment, reagents and informatics, we also provide on-site installation and training, ongoing support, phone consults and various training courses. We are here to help you improve your newborn screening program. CONSIDERING EXPANDING YOUR SCREENING PANEL? Why screen for X-linked adrenoleukodystrophy? X-linked adrenoleukodystrophy (X-ALD) occurs when certain fats (very long chain fatty acids, or VLCFAs) cannot be broken down in the body. This disease largely affects the nervous system and the adrenal glands. When an individual has X-ALD, the buildup of VLCFAs may disrupt the fatty covering (myelin) of the nerve cells in the brain and spinal cord causing the myelin to breakdown. Without myelin, the nervous system cannot function properly causing for example difficulties swallowing or weakness in the legs. However, these symptoms vary depending on the type and age of onset and other factors which are not well understood. In addition, the build of VLCFAs damages the outer layer of the adrenal glands (adrenal cortex). Prevalence X-ALD affects 1:17,000 to 1:50,000 males and females (ref. Theda et al. Molecular Genetics and Metabolism, 111 (014) worldwide. X-ALD affects males more severely and is more common in males. However, 0-40% of women who are carriers have symptoms in adulthood. Why screen for ADA SCID? Adenosine deaminase (ADA) deficiency is a systemic purine metabolic disorder caused by a defect in the enzyme adenosine deaminase. ADA deficiency can lead to severe combined immunodeficiency disease (SCID) which is usually fatal in infancy because of severe recurrent infections. Newborns with SCID may seem healthy at first because their mother s immune system protects them from infections for the first few weeks of life. However, without necessary treatment, common infections and vaccines can be life threatening. When diagnosis is made, permanent damage caused by infections or by metabolites is often present. Gene therapy, bone marrow transplantation, or enzyme therapy might be effective and life saving if performed early. Prevalence SCID affects 1 in 60,000 individuals worldwide (ref. van der Spek at al. J Clin Immunol, 35:4 (015). About 15% of all SCID cases are due to adenosine deaminase deficiency. Learn more on X-ALD and ADA SCID visit: www.newbornscreening.perkinelmer.com NeoBase MSMS kit may not be available in all countries, such as Canada and US. Please check out availability with your local PerkinElmer representative 940 Winter Street Waltham, MA 0451 USA P: (800) 76-4000 or (+1) 03-95-460 www.perkinelmer.com Wallac Oy PO Box 10 0101 Turku, Finland Phone: + 358 678 111 Fax: + 358 678 357 For a complete listing of our global offices, visit www.perkinelmer.com/contactus Copyright 017, All rights reserved. PerkinElmer is a registered trademark of All other trademarks are the property of their respective owners. 1599-981- BRO MSMS NeoBase kit December 017 Printed in Finland