Using Computational Fluid Dynamics Model to Predict Changes in Velocity properties in Stented Carotid Artery

Similar documents
Numerical Simulation of Blood Flow through Asymmetric and Symmetric Occlusion in Carotid Artery

Design and Simulation of Blocked Blood Vessel for Early Detection of Heart Diseases

Non-Newtonian pulsatile blood flow in a modeled artery with a stenosis and an aneurysm

CFD Analysis of Pulsatile Flow and Non-Newtonian Behavior of Blood in Arteries

JADAVPUR UNIVERSITY & 2 SCHOOL OF BIOSCIENCE AND ENGINEERING ABHIRUP ROY CHOUDHURY 1, KRITTIKA DASGUPTA 2, ABHIJIT CHANDA 1,2, DEBABRATA NAG 1

Analysis of the effects of plaque deposits on the blood flow through human artery

PHYSIOLOGICAL PULSATILE WAVEFORM THROUGH AXISYMMETRIC STENOSED ARTERIES: NUMERICAL SIMULATION

Contents 1 Computational Haemodynamics An Introduction 2 The Human Cardiovascular System

Numerical simulations of fluid mechanical interactions between two abdominal aortic branches

Effects of Non-Newtonian Behavior of Blood on Wall Shear Stress in an Elastic Vessel with Simple and Consecutive Stenosis

Refinements in Mathematical Models to Predict Aneurysm Growth and Rupture

Simulations of the blood flow in the arterio-venous fistula for haemodialysis

Hematocrit Level on Blood flow through a Stenosed Artery with Permeable Wall: A Theoretical Study

Post-conditioning. P a g e 1. To my Thesis Committee,

Numerical Simulation of Blood Flow in the System of Human Coronary Arteries with and without Bypass Graft

A Review of Study of the Effects of Plaque Deposits on the Blood Flow through Human Artery

A Multiphysics Simulation of a Healthy and a Diseased Abdominal Aorta

FOR many decades, cardiovascular disease has been one of

A computational fluid dynamics simulation study of coronary blood flow affected by graft placement

Blood Flow Simulation toward Actual Application at Hospital

Keywords: Angioplasty, Explicit finite elements method, Tube hidroforming, Stents.

Calculation of the Wall Shear Stress in the case of an Internal Carotid Artery with stenoses of different sizes

Blood flow in vessels with artificial or pathological geometrical changes

Computational analysis of effects of external carotid artery flow and occlusion on adverse carotid bifurcation hemodynamics

Mathematical and Computational study of blood flow through diseased artery

The relative effects of arterial curvature and lumen diameter on wall shear stress distributions in human right coronary arteries

BLOOD FLOW VISUALISATION THROUGH CAROTID BIFURCATION USING ANSYS CFD

FLUID MECHANICAL PERTURBATIONS INDUCED BY STENT IMPLANTATION: A NUMERICAL STUDY

Assessment of the Effects of Increasing Levels of Physiological Realism in the Computational Fluid Dynamics Analyses of Implanted Coronary Stents

Three Dimensional Large Eddy Simulation of Blood Flow and Deformation in an Elastic Constricted Artery

Simulation of Physiological Non-Newtonian Blood Flow through 3-D Geometry of Carotid Artery with Stenosis

54. Simulation and research on the influence of the shape and the geometrical parameters of a blood vessel bypass graft upon hemodynamics

4D model of hemodynamics in the abdominal aorta

Simulation of Blood Flow Coronary Artery with Consecutive Stenosis and Coronary-Coronary Bypass

COMPUTER SIMULATION OF BLOOD FLOW IN ARTERIES AFFECTED BY MULTIPLE ANEURYSM

Computational Fluid Dynamics Analysis of Blood Flow in Human Aorta

NUMERICAL SIMULATION OF EFFECTS OF REYNOLDS NUMBER ON NON-NEWTONIAN BLOOD FLOW WITH SPIRAL COMPONENT THROUGH A REGULAR STENOSED ARTERY

The Study of Abdominal Aortic Aneurysm Rupture Risk using Fluid-Structure Interaction

Modeling Flow Characteristics in Carotid Artery Bifurcation Afflicted with Atherosclerotic Plaques

FSI Analysis of Diseased Coronary using Patient Specific Data

Extraction and FSI modeling of Left coronary artery structure from patient s CTA images

Asymmetric flows of non-newtonian fluids in symmetric stenosed artery

Vascular Stenosis Asymmetry Influences Considerably Pressure Gradient and Flow Volume

A Multiphysics Simulation of a Healthy and a Diseased Abdominal Aorta

Simulations of pulsatile blood flow in tapered S-shaped inplane and out-of-plane coronary arteries

A Two-layered Model for the Analysis of Arterial Rheology

CARDIOVASCULAR disease is a leading cause of morbidity

¼ density (kg/m 3 ) ij ¼ Reynolds stress tensor (kg/m-s 2 ) ! ¼ specific dissipation rate ("=k)

Flow in re-stenosed artery after angioplasty

Original. Stresses and Strains Distributions in Three-Dimension Three-Layer Abdominal Aortic Wall Based on in vivo Ultrasound Imaging

Estimation and Comparison of T Graft Versus Conventional Graft for Coronary Arteries

Simulating the Motion of Heart Valves Under Fluid Flows Induced by Cardiac Contraction

ANALYSIS OF FLUID-STRUCTURE INTERACTION IN ABDOMINAL AORTIC ANEURYSM WITH HIGH AND NORMAL BLOOD PRESSURE

Computational Analysis on Commercially Available Stent Designs

Effects of surface geometry and non-newtonian viscosity on the flow field in arterial stenoses

Blood flow in S-shaped in-plane and out-of-plane coronary arteries

Non-Newtonian blood flow in human right coronary arteries: Transient simulations

3D MRI-Based Multicomponent FSI Models for Atherosclerotic Plaques

Research Article Hemodynamic Features in Stenosed Coronary Arteries: CFD Analysis Based on Histological Images

aneurysm initiation and fully developed aneurysms

Arteriovenous Graft Modeling and Hemodynamic Interpretation

Particle Hemodynamics Analysis after Coronary Angioplasty

Research Article Numerical Study of Turbulent Pulsatile Blood Flow through Stenosed Artery Using Fluid-Solid Interaction

BLOOD FLOW THROUGH A COMPOSITE STENOSIS IN CATHETERIZED ARTERIES INTRODUCTION

Simulation of Chemotractant Gradients in Microfluidic Channels to Study Cell Migration Mechanism in silico

Physiological flow analysis in significant human coronary artery stenoses

Saccular Aneurysm Formation in Curved and Bifurcating Arteries

Mathematical Modeling of Bingham Plastic Model of Blood Flow Through Stenotic Vessel

CPM Specifications Document Aortofemoral Normal:

NUMERICAL STUDY OF PULSATILE BLOOD FLOW IN THE CORONARY SYSTEM WITH THE RCA BYPASS GRAFT

ISSUES ON COMPUTATIONAL MODELING FOR COMPUTATION-AIDED DIAGNOSIS 臨床診断支援ツールのための計算力学モデリング

CPM Specifications Document Aortofemoral Normal:

FFR CT : Beyond FFR. Bon-Kwon Koo, MD, PhD. Seoul National University Hospital, Seoul, Korea. Seoul National University Hospital Cardiovascular Center

Numerical investigation on the blood flow characteristics considering the axial rotation in stenosed artery

FFR Fundamentals and Measurements

Edinburgh Imaging Academy online distance learning courses

Deposited on: 21 January 2009

Computational design of Intracranial Stent using 3D visualization system

Flow Analysis with Stent Placement in the Cerebral Aneurysm

ULTRASOUND BLOOD FLOW IMAGING IN CAROTID ARTERIES BEFORE AND AFTER ENDARTERECTOMY

Numerical Simulation of Blood Flow in the System of Human Coronary Arteries with Stenosis

BLOOD SIMULATION AND VIRTUAL BYPASS SURGERY

Research Article Effect of Pulsatile Flow Waveform and Womersley Number on theflowinstenosedarterialgeometry

A Mathematical Model for Flow and Diffusion through Stenotic Capillary-Tissue Exchange System

Study of Newtonian and Non-Newtonian Effect of Blood Flow in Portal Vein in Normal and Hypertension Conditions using CFD Technique

Modeling of a Ring for Blood Pressure Measurement in COMSOL Multiphysics for Medical Applications

A Review: Hemodynamics of Cerebral Aneurysm with Mathematical Modeling

Correlations of coronary plaque wall thickness with wall pressure and wall pressure gradient: A representative case study

Numerical analysis of blood flow in human abdominal aorta

Comparison of Stent Designs using Computational Fluid Dynamics

EVALUATION OF ABDOMINAL AORTIC ANEURYSM WALL STESS BASED ON FLOW INDUCED LOAD

Mathematical modeling of atherosclerotic plaque formation coupled with a non-newtonian model of blood ow

3D Modeling of Plaque Progression in the Human Coronary Artery

Non-axisymmetric Flow Development in Pulsatile Blood Flow through an Aneurysm

CPM Specifications Document Aortic Coarctation: Exercise

Effect of exercise on hemodynamic conditions in the abdominal aorta

Finite Element Modeling of Three-Dimensional Pulsatile Flow in the Abdominal Aorta: Relevance to Atherosclerosis

Numerical Analysis of Coronary Stent for Diverse Materials

Clinical Investigation and Reports

Numerical Study on Effects of Drug-coating Position of Drug-eluting Stents on Drug Concentration

Transcription:

Excerpt from the Proceedings of the COMSOL Conference 2010 Paris (COMSOL Conference) Using Computational Fluid Dynamics Model to Predict Changes in Velocity properties in Stented Carotid Artery Vaidehi Sheth* and Arthur Ritter, PhD Stevens Institute of Technology, Department of Biomedical Engineering *Corresponding Author: Castle Point on Hudson, Hoboken NJ 07030, vsheth1@stevens.edu. Abstract: Atherosclerosis is a disease that narrows, thickens, hardens and restructures a blood vessel due to substantial plaque deposit. In the Carotid Artery, the decision to treat using endarterectomy and stenting is determined by the velocity as measured by Doppler flow in the common Carotid Artery. The measured Doppler velocity as compared with the contra-lateral side has been correlated with the degree of stenosis. In some patients, the Doppler velocity after stenting is equivalent to or higher than before treatment. The hypothesis we are testing is that higher velocity measured after stenting may be due to the decreased compliance of the artery wall at the stent region. Geometric models of blood flow through an idealized carotid artery of different types and several degrees of constriction ranging from 0% to 100% were modeled. The overall objective of this paper is to create a computational model with pulsatile flow and walls with physiological compliance. The pressure variations in the compliant stenotic artery are subjected to prescribed pulsatile waveform. The computational simulations were performed in which the physiological flow through compliant axisymmetric stenotic blood vessel (carotid artery) was solved using commercial software COMSOL. COMSOL multiphysics[1] is used to solve this challenging problem involving fluid-structure interaction. Here we have demonstrated comparisons of the centerline velocities V 0 =0.40 m/s and V 55 =0.53 m/s with stenosed rate 0% and 55% respectively with the fluid-structure interaction and their velocity profiles under the physiological flow conditions in the compliant stenotic artery. With these values, flow prefers to avoid the stenosed region which causes additional load on the section with the stenosis. Therefore the structure seemed to translate marginally towards the stenosed section at bifurcation junction. Huge compliance mismatches though, would not be desirable especially due to greater deformations experienced by the arterial walls which affected the centerline velocity. 1 Introduction Atherosclerosis tends to develop in preferred sites, such as the bifurcations and flow divisions of the arteries. The development and progression of the atherosclerosis are related to the complex flow field occurring in the bifurcations of the arteries. It is widely known that there is the correlation between atherosclerosis lesion location and low or oscillating wall shear stress (Karino et al., 1988; Ku et al., 1985). Many cardiovascular diseases are closely associated with the flow conditions in the blood vessel. One major type of arterial disease is atherosclerosis which is characterized by localized accumulation of cholesterol and lipid substances. It is commonly referred to as a hardening of the arteries. It is caused by the formation of multiple plaques within the arteries. The symptom of atherosclerotic cardiovascular disease is heart attack or sudden cardiac death. The most artery flow disrupting events occur at locations with less than 50% of lumen narrowing (~20% stenosis is average) (Glagov et al., 1987)[2]. According to cardiac stress testing, traditionally the most commonly performed non-invasive testing method for blood flow limitations generally only detects lumen narrowing of ~75% or greater. From clinical trials, 20% is the average stenosis at plaques that subsequently rupture with resulting complete artery closure (Glagov et al., 1987). Most severe clinical events do not occur at plaques that produce high-grade stenosis. Only 14% of heart attacks occur from artery closure at plaques producing 75% or greater stenosis prior to the vessel closing. FSI (Fluid Structure Interaction) occurs when a fluid interacts with the solid structure, exerting pressure on it which may cause deformation in the structure and thus alter the flow of fluid itself. A fully coupled fluid-structure interaction means that the response of the solid is strongly affected by the response of the fluid, and vice versa. Thus, basic understanding of fluid-structure interaction is essential to understand these effects in cardiovascular system.

In the Carotid Artery, the decision to treat using endarterectomy and stenting is determined by the velocity as measured by Doppler flow in the common Carotid Artery. The measured Doppler velocity as compared with the contra-lateral side has been correlated with the degree of stenosis. In some patients, the Doppler velocity after stenting is equivalent to or higher than before treatment. The hypothesis we are testing is that higher velocity measured after stenting may be due to the decreased compliance of the artery wall at the stent region. An FSI model becomes essential to achieve a basic understanding of effects of various mechanical forces involved in arterial disease development. The present study is concerned with physiological flow both in elastic and rigid wall vessels with 0 and 50 % constriction of cross-sectional area in stenosed arteries. The objective of this study is to understand how the flow features and wall shear stress field change with the development of stenosis by numerically analyzing the interactions between a blood flow and a stenosed wall. In the present study, we investigate deformation along the wall and velocity field, in the different type of constriction of the blood vessel. 2 Formulation of the Problem Under certain conditions blood behaves as a Non- Newtonian substance. Therefore, when modeling the flow of blood it is inherently critical that the fluid properties are properly formulated. Studies show that the fluctuating blood viscosity is of negligible significance where the inertance of the blood is relatively large compared to the resistance [6]. Thus keeping constant viscosity through the model. Using the generalized Navier-Stokes equations which define a differential change in momentum within the blood is given by: - σ = 0 (2) where σ is the stress tensor. The artery itself was taken to consist of a Neo-Hookean hyperelastic material. This extension of Hooke s law is thought to better approximate the stress-strain relationship that exists within the artery. In the Comsol model this is realized by the Axial- Symmetric stress-strain mode. This is an approximation to the full three dimensional formulation and assumes loads only in the radial and axial directions. The boundary conditions introduced within the structural mechanics module take into account the coupling of the two physics. This is done by taking the computed pressure obtained from the Navier-Stokes equations and utilizing this as a load onto the artery walls 3 Comsol Model Figure 1 show the axial 3D symmetric model used in this study. The stented carotid artery consists of three major segments: stent, proximal and distal. The general dimensions are chosen to represent our model. Ls = 0.025 m, hs=0.0025m, h=0.0005m and Do = 0.0055, which results in hs/do= 0.5. The entire model was similarly defined as extended Y model. Modulus of elasticity for artery wall is Ea= 10 7 Pa [7]. Poisson s ratio for the stented portion was taken as 0.33 as of stainless steel which is considered to be homogenous and isotropic. The model is built using an axis symmetric stress-strain analysis type along with the time dependent incompressible Navier-Stokes module ρ u/ t - [η( u+( u) T )]+ ρ(u )u + p=f (1) Where ρ is the density of blood, η is the dynamic viscosity, and u is the velocity. This relation coupled with the field continuity equation u=0, completely defines the dynamics of blood flow through the artery. They are valid for the assumptions of the blood being Newtonian, incompressible and having a constant viscosity throughout. This relation is implemented within Comsol using the Incompressible Navier-Stokes (ns) mode. To solve the Navier-Stokes equations we introduce the boundary conditions being the known values of pressure at both the end of the blood domain. The structural mechanics of the artery is defined by the global equilibrium equations based on stress components. In a general form, this is given by: Figure 1: General Dimensions of the Model Flow is assumed to be Newtonian, incompressible, viscous and laminar. The dynamic viscosity of blood is taken as 0.005 Ns/m 2, and the density of the blood is taken as 1060 Kg/m 3. Flow through the vessel is driven by a pressure difference between the inlet and the outlet of the system in a pulsatile fashion. The boundary

conditions are assumed to be fluctuating pressure distribution as defined in figure 2. Figure 2: A typical pressure profile for human carotid artery. The fluid-structure interaction is taken into account with COMSOL by coupling the structural mechanics of the wall and fluid dynamics of the blood then simultaneously solving the system. The model with two different stenosed rate were solved in order to study the effects of the compliance - mismatch 4 Results The boundary deformations at all times for both the geometry configurations show that the maximum deformation does not exceed 10 μ m, which corresponds to a strain of less than 1%. In such a case, the one-way fluid-structural coupling assumption is a reasonable approximation. The maximum deformation was observed at t=0.52s, just after the time when the pressure load must have been the maximum, which is at the peak of the pressure profile.. consequence of the asymmetric geometry which causes an asymmetric flow field. The flow field is the same for all the cases with different stent properties for a given geometry configuration. When the stent is in the inlet section the flow is uniformly distributed among the two outlet sections. This is not the case when there is a stent placed in one of the outlet sections. In the latter situation, the stenosed region offers an obstruction to the flow and as is visible in the plot below, the flow prefers to go through the non-stenosed region rather than the stenosed one. The asymmetry also appeared to influence the maxima of the flow field in response to the pressure drop. It was observed that in the case when the stenosed region was in the inlet section, the maximum velocity magnitude was around the instant of the maximum pressure drop across the flow boundaries. On the other hand, when the stenosis was in the outlet section of the artery, it was observed that the maximum velocity magnitude was 0.04 s after the instant when the pressure drop was at its maximum (t = 0.5 s). This maximum value even sustained for around 0.08 s after which the velocity field started reducing in magnitude in accordance with the downward slope of the sinusoidal pressure function at the flow boundaries. This lag can be attributed to the asymmetry in the flow geometry causing flow disturbances due to which the nonuniform velocity field is out of phase with the pressuredrop across the flow boundaries. The lag is sustained for some time due to the viscous damping effects. There can also be a partial contribution of the asymmetric deformation. Owing to our one-way fluid-structure coupling simplification, this effect has not been taken into account. Analysis: Centerline Velocity Calculation Flow field comparison for the two geometric configuration around the instant of maximum pressure drop. Figure 3 Figure 4 Figure 3 & 4 Typical deformed arterial boundaries plot at t = 0.52s. The deformation is in microns for inlet and oulet arterial section respectively. On a broad level, it is observed that if the stenosed region is in the outlet section, it undergoes more deformation. The deformation is also non-uniformly distributed when the stent is in one of the outlet sections. This is a natural Figure 5: Flow field at 0%stenosed rate

computational model to study the blood flow through an arterial section with a stenosed region having a stent placed in it. The stenosed region with the stent was considered as a new subdomain with the application of the lumped parameter model. The stent region s mechanical properties were varied during the computational study. Figure 6: Flow field at 55%stenosed rate Figure 7 shows the comparison of the centerline velocities simulated for both 0% and 55% stenosed rate, constriction in the inlet arterial cross-sectional area by referring Fig 5 and 6. The centerline axial velocity profile has the same pattern of the inlet velocity waveform. During accerleration and early flow deceleration, there is small difference of the velocity profiles between the two model. Similarly, Figure 8 Shows the comparison of the centerline velocities for both 0% and 55%, but in oulet arterial section. Velocity m/s 0.6 0.5 0.4 0.3 0.2 0.1 0 0 20 40 Distance mm Vel ( 55% Vel (0% Figure 7 Figure 8 Figure 7 and 8 Matched Centerline velocity for Inlet and oulet arterial Section arterial section. According to the clinical point of view, shear stress is more essential. When blood force distribution acts on the boundary surfaces of stenosed area, higher shear stress occurs at the throat section of the stenosed area and rapidly drops reversing its direction. If the stenosed rate is increased, higher stress occurs at the vicinity of the stenosed area, which means the blood flow could be closure leading to higher pressure drop and increasing the centreline velocity at higher stenosed rate. That results in decreasing compliance effect. 5 Conclusion and Future Recommendation: The present work illustrated the implementation of a oneway coupled fluid-structure interaction (FSI) based Velocity m/s 0.6 0.5 0.4 0.3 0.2 0.1 0 0 50 100 Distance mm Vel ( 55% Vel (0% This parametric study yielded that a compliance mismatch can prevent strokes that typically occur in the stenosed region due to the reduction of static pressure. Huge compliance mismatches though, would not be desirable especially due to greater deformations experienced by the arterial walls. The stenosed region was placed at different positions to see the effect of asymmetry on the arterial wall deformation. The asymmetry caused non-uniformity in the flow field which influenced the response of the arterial walls and the stented region. It was observed that flow prefers to avoid the stenosed region which causes additional load on the section with the stenosis. The structure therefore, seemed to translate marginally towards the stenosed section at the bifurcation junction. These findings need to be confirmed by either a two way coupled FSI study or a fully coupled multiphysics application supported by COMSOL Multiphysics. The computational effort for the same would be huge and could not be implemented within the framework of the current project. The promising trend in increase in the computational resources available on a desktop holds potential for such a fully coupled study to be performed in the near future. REFERENCES 1) Comsol Multiphysics, Model Library 2) Glagov S., E. Weisenberg, C. K. Zarins, R. Stankunavicius and G. J. Kolettis, 1987, Compensatory enlargement of human atherosclerotic coronary arteries, N. Engl. J. Med. 316(22), 1371-1375 3) Karino, T., T. Asakura and S. Mabuchi, 1988, Flow patterns and preferred sites of atherosclerosis in human coronary and cerebral arteries, in Role of blood flow in atherosclerosis (editor:y. Yoshida, T. Yamaguchi, C. C. Caro, S. Glagov, and R. M.Nerem), Springer-Verlag.

4) B. Bhargava, G. Karthikeyan, A. S. Abizaid and R. Mehran, New approaches to preventing restenosis, BMJ, 327, 274-279 (2003). 5) Ku. D. N, C. K. Zarins, D. P. Giddens and S. Glagov., 1985, Early atherosclerosis and pulsatile flow in the human carotid bifurcation, Arterioscler. Thromb, Vasc. Biol. 5, 293-302. 6) Lee. K. W and X. Y. Xu, 2002, Modelling of flow and wall behavior in a mildly stenosed tube, Medical Engineering & Physics 24, 575-586 7) A. Tortoriello and G. Pedrizzetti, Flow-tissue interaction with compliance mismatch in a model stented artery. J. Biomechanics, 37, 1-11 (2004) 8) Tang D., C. Yang, S. Kobayashi and D. N. Ku, 2001b, Steady flow and wall compression in stenotic arteries: a three-dimensional thick-wall model with fluid-wall interactions, J. Biomech. Eng. 123(6), 548-557.