Lumbosacral Fixation Using the Diagonal S2 Screw for Long Fusion in Degenerative Lumbar Deformity: Technical Note Involving 13 Cases

Similar documents
Sacropelvic Fixation. Ahmet Alanay M.D. Professor. Acıbadem Maslak Hospital Comprehensive Spine Center Istanbul TURKEY

Pelvic Fixation. Disclosures 5/19/2017. Rationale for Lumbo-pelvic Fixation

Lumbosacral fixation using sacroiliac buttress screws: a modification to the Jackson technique with intrasacral rods

The sacrum is a complex anatomical structure.

Navigated placement of iliac bolts: description of a new technique

The Kickstand Rod technique for correction of coronal imbalance in patients with adult spinal deformity: theory and technical considerations

Module: #15 Lumbar Spine Fusion. Author(s): Jenni Buckley, PhD. Date Created: March 27 th, Last Updated:

TECHNICAL BROCHURE. Capture Facet Fixation System

4.5 System. Surgical Technique. This publication is not intended for distribution in the USA.

A U X I L I A R Y C O N N E C T O R S Surgical Technique

T.L.I.F. Surgical Technique. Featuring the T.L.I.F. SG Instruments, VG2 PLIF Allograft, and the MONARCH Spine System.

operative technique Universal Application

Pedicle screw placement accuracy in thoracic and lumbar spinal surgery with a patient-matched targeting guide: A cadaveric study

Dorsal Cervical Surgeries and Techniques


L8 Spine System SURGICAL TECHNIQUE. Add: No.1-8, Tianshan Road, Xinbei District, Changzhou, Jiangsu, China

USS Variable Axis Screw

T.L.I.F. Transforaminal Lumbar Interbody Fusion

Threshold Pedicular Fixation System Surgical Technique

I. II. SPINAL SYSTEM SURGICAL TECHNIQUE GUIDE

Alamo T Transforaminal Lumbar Interbody System Surgical Technique

The Most Reliable Spinal Solution

Thoracolumbar Solutions. Sacroiliac Joint Fusion System. Surgical Technique Guide

Outcomes in Adult Scoliosis Patients Who Undergo Spinal Fusion Stopping at L5 Compared with Extension to the Sacrum

Spinal deformities, such as increased thoracic

Pedicle screws have become common and reliable. Cortical bone trajectory for lumbosacral fixation: penetrating S-1 endplate screw technique

Proper detailed parameters for S1 sacral alar iliac screw placement in the Chinese population, a 3D imaging study

Valencia Pedicle Screw Surgical Technique

Pedicle subtraction osteotomy for the treatment of fixed sagittal imbalance: Surgical technique.

ASJ. Radiologic and Clinical Courses of Degenerative Lumbar Scoliosis (10 25 ) after a Short-Segment Fusion. Asian Spine Journal.

Stereotactic navigation with the O-arm for placement of S-2 alar iliac screws in pelvic lumbar fixation

PARADIGM SPINE. Minimally Invasive Lumbar Fusion. Interlaminar Stabilization

Association between bicortical screw fixation at upper instrumented vertebra and risk for upper instrumented vertebra fracture

Treatment of thoracolumbar burst fractures by vertebral shortening

Dymaxeon Spine System. Simple, Streamlined, Smart. Surgical Procedure

U.S. MARKET FOR MINIMALLY INVASIVE SPINAL IMPLANTS

nvt Transforaminal Lumbar Interbody Fusion System

VTI INTERFUSE S SURGICAL TECHNIQUE FORWARD THINKING FOR THE BACK.

Original Article Clinics in Orthopedic Surgery 2016;8:

ISPUB.COM. T Iizuka, S Yamada INTRODUCTION CASE REPORT

Long lumbar instrumented fusions have been described

X-spine Surgical Technique

nva Anterior Lumbar Interbody Fusion System

EXACTECH SPINE. Operative Technique. Cervical Spacer System. Surgeon focused. Patient driven. TM

OPERATIVE TECHNIQUE. anterior cervical plating system

Table of Contents.

USS II ILIO-SACRAL Modular System for Stable Fixation in the Sacrum and Illium

Adolescent Idiopathic Scoliosis

nvp Posterior Lumbar Interbody Fusion System

Original Policy Date

Interbody fusion cage for the transforaminal approach. Travios. Surgical Technique

Single-Thread Screw Available in 25-45mm lengths (5mm Increments) Dual-Thread Screw Available in 30-45mm lengths (5mm Increments)

ProDisc-L Total Disc Replacement. IDE Clinical Study.

Royal Oak Cervical Plate System

TM TM Surgical Technique

There is No Remarkable Difference Between Pedicle Screw and Hybrid Construct in the Correction of Lenke Type-1 Curves

EXCELLA ll. Spinal System

SURGICAL TECHNIQUE MANUAL. InterFuse T

Zimmer Facet Screw System Surgical Technique

Thoracic Lumbar Pelvic Posterior Anterior. Universal Spine System (USS). A versatile side-loading system portfolio.

Reduction of High-grade Spondylolisthesis Using a Transvertebral Surgical Approach in a Child. A Case Report and Review of the Literature.

SURGICAL TECHNIQUE ROI-T TM TLIF INTERSOMATIC IMPLANT TRANS-FORAMINAL APPROACH

*smith&nephew CONTOUR

Surgical Technique Guide

Proximal junctional kyphosis in adult spinal deformity with long spinal fusion from T9/T10 to the ilium

Degenerative spondylolisthesis at the L4 L5 in a 32-year-old female with previous fusion for idiopathic scoliosis: A case report

Percutaneous Posterior Fixation: A Unique Entity to minimize Further Damage to Patient with Traumatic Spine

SURGICAL TECHNIQUE GUIDE TRESTLE. Anterior Cervical Plating System

Screws versus hooks: implant cost and deformity correction in adolescent idiopathic scoliosis

Int J Clin Exp Med 2018;11(2): /ISSN: /IJCEM Yi Yang, Hao Liu, Yueming Song, Tao Li

VTI INTERLINK PEDICLE SCREW SYSTEM

Clinical Incidence of Sacroiliac Joint Arthritis and Pain after Sacropelvic Fixation for Spinal Deformity

Spondylolysis repair using a pedicle screw hook or claw-hook system. a comparison of bone fusion rates

Analysis of instrumentation failures after three column osteotomies of the spine

Spinal Terminology Basics

ASJ. Surgical Treatment of Adult Degenerative Scoliosis. Asian Spine Journal. Introduction. Classification of Adult Scoliosis

Technique Guide. C1/C2 Access System. Percutaneous transarticular screw fixation.

Spinal System. Aesculap Posterior Thoracolumbar Stabilization System S 4. Aesculap Spine

Focal Correction of Severe Fixed Kyphosis with Single Level Posterior Ponte Osteotomy and Interbody Fusion

Royal Oak IBFD System Surgical Technique Posterior Lumbar Interbody Fusion (PLIF)

Perioperative Complications of Pedicle Subtraction Osteotomy

Trephine System. Principle-based anterior lumbar interbody fusion.

PARADIGM SPINE. Brochure. coflex-f Minimally Invasive Lumbar Fusion

Ref: Q400-09T1 EBI Spine. September 05/VS02. c/o BIOMET Spain Orthopaedics, S.L.

Introduction. Our hope is that this Surgical Technique Guide enhances your knowledge and contributes to clinical success for your patients.

Regions of the Spine

VTI INTERFUSE T SURGICAL TECHNIQUE FORWARD THINKING FOR THE BACK. 1/20

L5-S1 Spondylolysis/listhesis in children & adolescents: When is surgery indicated? Hubert Labelle, MD

EIT TLIF Cage. For Natural Bone Ingrowth with EIT Cellular Titanium

Disclosures. Sacroiliac Joint (SIJ) Pain. Modified Triplanar Fluoroscopic Approach in Percutaneous Fixation of Sacroiliac Joint 5/12/2017

Corporate Medical Policy

Axial Skeleton: Vertebrae and Thorax

Surgical Technique Manual

Spinal Deformity Pathologies and Treatments

A Fusion of Versatility, Performance and Ease.

Procedure Coding Made Simple Five principles will help you capture appropriate charges for spine surgeries.

Surgical Technique. Apache Posterior Lumbar Interbody Fusion Apache Transforaminal Lumbar Interbody Fusion

Technique Guide. NFlex. Semi-rigid rods for posterior lumbar stabilization.

Transcription:

Technical Note Clinics in Orthopedic Surgery 2013;5:225-229 http://dx.doi.org/10.4055/cios.2013.5.3.225 Lumbosacral Fixation Using the Diagonal S2 Screw for Long Fusion in Degenerative Lumbar Deformity: Technical Note Involving 13 Cases Ye-Soo Park, MD, Hong-Sik Kim, MD, Seung-Wook Baek, MD, Sang-Hyun Lee, MD Department of Orthopaedic Surgery, Hanyang University Guri Hospital, Hanyang University College of Medicine, Guri, Korea Placing instrumentation into the ilium has been shown to increase the biomechanical stability and the fusion rates, but it has some disadvantages. The diagonal S2 screw technique is an attractive surgical procedure for degenerative lumbar deformity. Between 2008 and 2010, we carried out long fusion across the lumbosacral junction in 13 patients with a degenerative lumbar deformity using the diagonal S2 screws. In 12 of these 13 patients, the lumbosacral fusion was graded as solid fusion with obvious bridging bone (92%). One patient had a rod dislodge at one S2 screw and breakage of one S1 screw and underwent revision nine months postoperatively. So, we present alternative method of lumbopelvic fixation for long fusion in degenerative lumbar deformity using diagonal S2 screw instead of iliac screw. Keywords: Long fusion, Diagonal S2 screw, Iliac screw, Degenerative lumbar deformity Placing instrumentation into the ilium or sacrum as an adjunct to S1 pedicle screws has been shown to increase the biomechanical stability of lumbosacral constructs, and high fusion rates have been reported. 1,2) However, iliac fixation can require separate fascial or skin incisions or the use of offset connectors. 3,4) We report an alternative method of lumbopelvic fixation to address some of these drawbacks called the diagonal S2 screw technique. TECHNIQUE Imaging The ability to place a diagonal S2 screw requires a thorough understanding of each individual patient s anatomy. Standing anteroposterior and lateral lumbar radiographs and an anteroposterior pelvic radiograph should be obtained. The overall alignment of the spine and pelvis in Received January 21, 2013; Accepted March 2, 2013 Correspondence to: Ye-Soo Park, MD Department of Orthopaedic Surgery, Hanyang University Guri Hospital, Hanyang University College of Medicine, 153 Gyeongchun-ro, Guri 471-701, Korea Tel: +82-31-560-2316, Fax: +82-31-557-8781 E-mail: hyparkys@hanyang.ac.kr both the coronal and sagittal plane should be evaluated carefully. Preoperative computerized tomography (CT) should be performed to evaluate for absent or small pedicles and congenital and other bony abnormalities. Depending on the experience, skill, and comfort of the operating surgeon, intraoperative fluoroscopy is recommended but not required. Diagonal S2 screw fixation technique The affected area is first exposed through the posterior midline approach followed by lateral dissection as far as the transverse process. The lower medial edge of the S1 dorsal foramen and the upper medial edge of the S2 dorsal foramen was carefully exposed (Fig. 1). The entry point is on the junction of the midlines of the foramen and the bone arch between them. After choosing the entry point, marking the entry point with a small sharp owl. And confirm the trajectory to the anterior cortex with a straight probe. The probe was angled laterally 30 to 35 degrees, and tilted cephalad 15 to 20 degrees (Fig. 2). The probe was passed through three-dimensional line to percuss the anterior cortex. On touching the cortex, the depth was measured, then 10 mm was added to the cortical thickness Copyright 2013 by The Korean Orthopaedic Association This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. Clinics in Orthopedic Surgery pissn 2005-291X eissn 2005-4408

226 Fig. 1. Entry point of the S2 alar screw (arrow) and the midpoint of the line from the medial margin of the S1 dorsal foramen and the medial margin of the S2 dorsal foramen. itself. The probe was inserted along the cortex with a mallet. It s important that maintain the probe exact trajectory to the anterior cortex hole. The probe was reinserted along the anterior cortex to assure the exact trajectory of the S2 6.0-mm-diameter screw. An attempt was then made to place the screw with the tip contacting the triangular area of cortical bone at the anterior, inferior, and lateral boundaries of the sacral ala without penetrating through these boundaries. Lateral penetration of the screw will violate the sacroiliac joint, which could result in painful arthropathy. Significant anterior penetration in this area can result in impingement of the L5 nerve root, which runs anterior to the sacrum in this area. A portable lateral radiograph was used to confirm the exact angle in the sagittal plane. Owing to the curve of the pelvic iliopectineal line, the screw tip projected 10 to 20 mm in front of the S1 anterior cortex on the lateral radiograph. Subsequently, a 6.0-mm-diameter, 50-mm-long variable angle screw was inserted. Posterolateral fusion was accomplished using autogenous iliac bone harvested from the posterior iliac crest and with a local autograft obtained from the spinous processes of the lumbar spine, bone removed from the partial facetectomy and laminectomy. Finally, rods were applied to the pedicle screws and the screws were tightened to apply the compressive load to the bone graft. Patients Between 2008 and 2010, we carried out long fusion(more than 4 segments) across the lumbosacral junction in 13 patients with a degenerative lumbar deformity using the operative technique described. All procedures were performed by a single surgeon. The mean patient age at the time of the operation was 71.4 years (range, 61 to 79 years), and the mean follow-up period was 26.6 months (range, 12.9 to 40.24 months). The mean fusion level was 4.7 levels (range, 4 to 8 levels) (Table 1). All 13 patients were evaluated with postoperative CT scans that were performed no sooner than six months postoperatively. In 12 of these 13 patients, the lumbosacral fusion was graded by an independent radiologist as Fig. 2. (A) The lateral trajectory of the S2 alar screw varied somewhat among patients but was typically between 30 and 35 degrees in the lateral planes. It did not penetrate the sacroiliac joint laterally or the S1 ventral foramen medially. (B) The superior trajectory of the S2 alar screw was a longer screw insertion and did vary somewhat among patients, but was typically between 15 and 20 degrees in the superior planes. It did not penetrate the anterior cortex as this could cause impingement of the L5 nerve root and injury to the internal iliac vessels.

227 Table 1. Patient Demographics and Clinical Results No. Age Sex Diagnosis Procedure Follow-up period Visual analogue scale Oswestry disability index Preoperative Postoperative Preoperative Postoperative Complications 1 61 F Degenerative stenosis L2-S2 fusion 12.9 6 2 14 4 2 72 F Degenerative stenosis L1-S2 fusion 15.7 8 2 23 6 3 69 F Degenerative stenosis L2-S2 fusion 28.4 7 1 19 4 Pseudarthrosis 4 68 F Degenerative scoliosis, L2-S2 fusion 35.4 5 1 13 3 5 72 F Degenerative stenosis L2-S2 fusion 32.1 8 1 31 10 6 74 F Degenerative stenosis L1-S2 fusion 30.4 5 2 18 6 7 79 F Degenerative stenosis L2-S2 fusion 15.7 9 3 26 7 8 69 F Lumbosacral pseudoarthrosis, L2-S2 fusion (revision) 32.6 8 3 24 8 9 72 F Degenerative stenosis L2-S2 fusion 36.8 9 4 16 5 10 72 F Degenerative stenosis L2-S2 fusion 34.4 9 3 39 13 11 71 M Lumbosacral pseudoarthrosis, L1-S2 fusion (revision) 15 7 2 33 16 12 73 F Degenerative scoliosis, T10-S2 fusion 40.24 9 2 25 6 Rod dislodge 13 77 F Degenerative stenosis T9-S2 fusion 16.6 9 4 27 9 solid fusion with obvious bridging bone (Fig. 3). The one patient who did not have solid fusion remained greatly improved in terms of her back pain compared with before surgery and did not have any symptoms consistent with pseudarthrosis. There were no complications that occurred as a result of the diagonal S2 screw placement during the follow-up period. One patient was a farmer and insisted upon maintaining her rural life and farming work. She had a rod dislodge at one S2 screw and breakage of one S1 screw resulting in kyphotic deformity two months postoperatively. As a result, this patient did experience painful hardware prominence of the dislodged rod requiring removal, and underwent revision of the T10 S1 fusion nine months postoperatively. DISCUSSION Fig. 3. Two years postoperatively, there was no evidence of screw loosening or pseudarthrosis at the lumbosacral junction. Achieving solid fusion at the lumbosacral junction in deformity surgery is challenging. 5) As is often the case, osteopenia at S1 limits the quality of fixation there; thus, only one level of fixation anchors the construct solidly at the lumbosacral junction. Using just the S1 promontory fixation in adult deformity surgery is associated with pseudarthrosis at L5 S1. 6) The high incidence of pseudarthrosis at the lumbosacral junction has led authors to recommend anterior interbody fusion and supplemental fixation at the lumbosacral junction 6,7) as a part of complete lumbosacral

228 fixation. 3,6) The major advantage in sacral-pelvic fixation is the assembly the instrumented fusion segment to the ilium. There are two fundamental fixation techniques for instrumentation of lumbosacral junction all sacral fixation and sacro-iliac fixation. The difference between these two techniques is S2 screw fixation versus iliac screw fixation. The iliac screw fixation technique is insertion of fully- or partially-threaded iliac screws and connected with the longitudinal rod in the lumbar spine through monoaxial or polyaxial connectors and offsets. The advantage of iliac screw system is modularity, easier placement of implants, placement of more than one iliac screw on each side, and biomechanical compatibility with a proper pivot point. 2) However, iliac screw fixation technique has potential risk of substantial morbidity. The technique has higher risk of infection and bleeding because of extensive surgical exposure and poor soft tissue coverage. More practically, the iliac implants may be prominent and interfere with iliac graft harvest. In addition, there are other complications associated with iliac screw fixation including loosening, injury of neurovascular structures in the sciatic notch, violation of acetabulum, and hardware prominence. 1,8) Furthermore, Kuklo et al. 1) reported an infection rate of 4% associated with lumbosacral fusion using bilateral S1 and iliac screws. The sacral alar screw has been used as an alternative to the iliac screw and has been tested biomechanically. Leong et al. 9) found that a construct consisting of bicortical S1 pedicle screws in combination with bicortical S2 alar screws that were inserted 30 degrees anterolaterally was significantly stronger than constructs using bicortical S1 pedicle screws alone. In a study by Zindrick et al., 10) second sacral pedicle is weakest location and screws aimed laterally into the ala at 45 degrees resist larger axial pull-put loads than straight anteriorly into the ala. But, diagonal insertion of S2 screw did not tested and S2 screw is not embedded firmly than iliac screw. To overcome the iliac screw disadvantages, the diagonal S2 screw for lumbo-sacral fixation was described here. The diagonal S2 screw has many potential advantages compared with iliac screw fixation such as a lower profile, avoidance of extra soft tissue dissection, no competition with iliac bone graft harvest, and easier salvage if ever infected. But in patient with severe sagittal imbalance, authors thought iliac screw fixation is appropriate option for preventing pseudarthrosis. Authors used a 6.0-mm-diameter, 50-mm-long variable angle screw in most of the patients and it was sufficient for solid lumbo-sacral fixation. More larger screw is able to provide greater stability, but further biomechanical testing would have to be accomplished to come to any firm conclusion regarding the strength of S2 screws. In our cases, a posterolateral fusion was performed in 13 patients and there was no interbody fusion case. Interbody fusion provides mechanical advantages in terms of graft compression and a large, well vascularized fusion surface. But, only posterolateral fusion with S2 screw fixation provided high fusion rate (12/13) and authors think interbody fusion doesn t need in our techniques. Authors suggest that the S1-diagonal S2 screw construct is an appropriate alternative to the S1-iliac screw construct and it presents certain clinical advantages. However, the short- and long-term effects of the diagonal S2 screw have not been completely evaluated. Further data are needed to fully evaluate the diagonal S2 technique. CONFLICT OF INTEREST No potential conflict of interest relevant to this article was reported. REFERENCES 1. Kuklo TR, Bridwell KH, Lewis SJ, et al. Minimum 2-year analysis of sacropelvic fixation and L5-S1 fusion using S1 and iliac screws. Spine (Phila Pa 1976). 2001;26(18):1976-83. 2. McCord DH, Cunningham BW, Shono Y, Myers JJ, McAfee PC. Biomechanical analysis of lumbosacral fixation. Spine (Phila Pa 1976). 1992;17(8 Suppl):S235-43. 3. Lebwohl NH, Cunningham BW, Dmitriev A, et al. Biomechanical comparison of lumbosacral fixation techniques in a calf spine model. Spine (Phila Pa 1976). 2002;27(21):2312-20. 4. Tsuchiya K, Bridwell KH, Kuklo TR, Lenke LG, Baldus C. Minimum 5-year analysis of L5-S1 fusion using sacropelvic fixation (bilateral S1 and iliac screws) for spinal deformity. Spine (Phila Pa 1976). 2006;31(3):303-8. 5. Ahn DK, Park HS, Choi DJ, Kim KS, Yang SJ. Survival and prognostic analysis of adjacent segments after spinal fusion. Clin Orthop Surg. 2010;2(3):140-7. 6. Edwards CC 2nd, Bridwell KH, Patel A, Rinella AS, Berra A, Lenke LG. Long adult deformity fusions to L5 and the

229 sacrum: a matched cohort analysis. Spine (Phila Pa 1976). 2004;29(18):1996-2005. 7. Kim YJ, Bridwell KH, Lenke LG, Cho KJ, Edwards CC 2nd, Rinella AS. Pseudarthrosis in adult spinal deformity following multisegmental instrumentation and arthrodesis. J Bone Joint Surg Am. 2006;88(4):721-8. 8. Moshirfar A, Rand FF, Sponseller PD, et al. Pelvic fixation in spine surgery: historical overview, indications, biomechanical relevance, and current techniques. J Bone Joint Surg Am. 2005;87 Suppl 2:89-106. 9. Leong JC, Lu WW, Zheng Y, Zhu Q, Zhong S. Comparison of the strengths of lumbosacral fixation achieved with techniques using one and two triangulated sacral screws. Spine (Phila Pa 1976). 1998;23(21):2289-94. 10. Zindrick MR, Wiltse LL, Widell EH, et al. A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. Clin Orthop Relat Res. 1986;(203):99-112.