Sensitive Analysis of Commonly Used Artificial and Natural Sweeteners Including Stevia and Their Impurities and Degradation Products

Similar documents
Analysis of Commercially Available Products Containing Stevia

Determination of Clinically Relevant Compounds using HPLC and Electrochemical Detection with a Boron-Doped Diamond Electrode

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis

Sialic Acid Determination in Glycoproteins: Comparison of Two Liquid Chromatography Methods. Experimental. Introduction. Method 1.

Rapid and Direct Analysis of Free Phytosterols by Reversed Phase HPLC with Electrochemical Detection

Mercury Speciation Determinations in Asian Dietary Supplements

Improved Extraction and Analysis of Hexavalent Chromium from Soil and Water

Direct Determination of Native N-linked Glycans by UHPLC with Charged Aerosol Detection

Determination of Ethyl Sulfate Impurity in Indinavir Sulfate Drug Using Ion Chromatography

A Versatile Detector for the Sensitive and Selective Measurement of Numerous Fat-Soluble Vitamins and Antioxidants in Human Plasma and Plant Extracts

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column

The Determination of Sugars in Molasses by High-Performance Anion Exchange with Pulsed Amperometric Detection

Analysis of Common Sweeteners and Additives in Beverages with the PerkinElmer Flexar FX-15 System Equipped with a PDA Detector

Determination of Steviol Glycosides by HPLC with UV and ELS Detections

Determination of Carbohydrates in Kombucha Using HPAE-PAD

Detection and Quantification of Inorganic Arsenic in Fruit Juices by Capillary Ion Chromatography with Suppressed Conductivity Detection

Carl Fisher, Terri Christison, Hua Yang, Monika Verma, and Linda Lopez Thermo Fisher Scientific, Sunnyvale, CA, USA

A Rapid UHPLC Method for the Analysis of Biogenic Amines and Metabolites in Microdialysis Samples

Analysis of Phospholipids in Natural Samples by Normal Phase HPLC and Corona Charged Aerosol Detection

Quantitative Analysis of Carbohydrates and Artificial Sweeteners in Food Samples Using GFC- MS with APCI Interface and Post-column Reagent Addition

Analysis of Emulsifiers in Foods by High Pressure Liquid Chromatography and Corona Charged Aerosol Detection

Thermo Scientific Dionex CarboPac MA1 Column

Impurity Profiling of Carbamazepine by HPLC/UV

Analysis of Food Sugars in Various Matrices Using UPLC with Refractive Index (RI) Detection

Marc Plante, Bruce Bailey, and Ian N. Acworth Thermo Fisher Scientific, Chelmsford, MA, USA

columns CarboPac PA20 Column

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Determination of Polymerized Triglycerides by High Pressure Liquid Chromatography and Corona Veo Charged Aerosol Detector

Measuring Phytosterols in Health Supplements by LC/MS. Marcus Miller and William Schnute Thermo Fisher Scientific, San Jose, CA, USA

Confident, lower-pressure analysis of carbohydrates, alcohols, and organic acids. Agilent Hi-Plex Ligand-Exchange HPLC Columns

LC-MS/MS Method for the Determination of Tenofovir from Plasma

Carbohydrate Analysis and Purification

Determination of Plant-Derived Neutral Oligo- and Polysaccharides Using the CarboPac PA200

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine

Determination of Benzoate in Liquid Food Products by Reagent-Free Ion Chromatography

Robust and Fast Analysis of Tobacco-Specific Nitrosamines by LC-MS/MS

A HPAE-PAD Chromatographic Assay for Carbohydrates in Urine as a Measure of Intestinal Permeability

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

Rebaudioside a From Multiple Gene Donors Expressed in Yarrowia Lipolytica

Steviol Glycosides from Stevia rebaudiana Bertoni

Identification and Quantification at ppb Levels of Common Cations and Amines by IC-MS

Technological Experiences and Advances in the Beverage Sector

HC-75 Calcium Form. 305 x 7.8 mm HC-75 Calcium Form (P/N 79436)

[ APPLICATION NOTE ] Profiling Mono and Disaccharides in Milk and Infant Formula Using the ACQUITY Arc System and ACQUITY QDa Detector

Novel, Universal Approach for the Measurement of Natural Products in a Variety of Botanicals and Supplements, Part 2

2.122 Other Alternative Sweeteners

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine

Determination of Inorganic Ions and Organic Acids in Non-Alcoholic Carbonated Beverages

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

Determination of Sucralose Using HPAE-PAD

Physical Properties. Silica

Direct Analysis of Multicomponent Adjuvants by HPLC with Charged Aerosol Detection

Fast UHPLC Methods for Analysis of Amino Acids

Determination of Water- and Fat-Soluble Vitamins in Nutritional Supplements by HPLC with UV Detection

Determination of Carbohydrates in Beverages and Milk Products by HPAE-PAD and Capillary HPAE-PAD

Application Note. Authors: C. Ledesma, M. Gibert, J.R. Gibert Ingenieria Analitica S.L. Extracts from various food products

Sugars in Honey Using HPAE-PAD: What Is the Best Column?

ANTEC LEYDEN. Analysis of Carbohydrates in Food and Beverages using Anion-Exchange Chromatography and Pulsed Amperometric. Introduction.

Thermo Fisher Scientific, Sunnyvale, CA, USA; 2 Thermo Fisher Scientific, San Jose, CA, USA

A New Era in SFC Column Technology

Determination of Clinically Relevant Compounds using HPLC and Electrochemical Detection with Boron-Doped Diamond Electrode

Characterization of Used Cooking Oils by High Performance Liquid Chromatography and Corona Charged Aerosol Detection

Ensuring High Sensitivity and Consistent Response in UHPLC-MS Analyses

Development and Validation of a Polysorbate 20 Assay in a Therapeutic Antibody Formulation by RP-HPLC and Charged Aerosol Detector (CAD)

APPLICATIONS TN Determination of Sugars in Animal Feed using HPLC-ELSD

HPLC Analysis of Sugars

GlycanPac AXR-1 Columns

Probing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection INTRODUCTION

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

Bioanalytical Quantitation of Biotherapeutics Using Intact Protein vs. Proteolytic Peptides by LC-HR/AM on a Q Exactive MS

Enhanced LC-MS Sensitivity of Vitamin D Assay by Selection of Appropriate Mobile Phase

Separation of 15 Underivatized Saccharide and Sialic Acid USP Standards

Innovation Spotlight:

LC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D

Carbohydrates in Food

Core-Shell Technology for Proteins and Peptides

Unequalled durability against water elution. % tr

CarboPac PA-100 Column for Oligosaccharide Analysis

Application Note. Sensitive analysis of the lactose content of lactose-free labelled products using HPAEC-PAD. Summary.

Continuation of Reversed-Phase HPLC Analysis Studies of Steviol Glycosides Isolated From Stevia rebaudiana Bertoni

Comparison of Full Scan MS2 and MS3 Linear Ion Trap Approaches for Quantitation of Vitamin D

Simultaneous Analysis of Active Pharmaceutical Ingredients and Their Counter-Ions Using a Mixed-Mode Column

Sugar Reformulation What are the options for alternative sweeteners?

Rapid determination of phosphate and citrate in carbonated soft drinks using ion chromatography

Increased Identification Coverage and Throughput for Complex Lipidomes

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

[ APPLICATION NOTE ] The Separation of 8 -THC, 9 -THC, and Their Enantiomers by UPC 2 Using Trefoil Chiral Columns INTRODUCTION APPLICATION BENEFITS

The Investigation of Factors Contributing to Immunosuppressant Drugs Response Variability in LC-MS/MS Analysis

Determination of Sucralose in Reduced- Carbohydrate Colas using High-Performance Anion-Exchange Chromatography with Pulsed Amperometric Detection

Analysis of Counterfeit Antidiabetic Drugs by UHPLC with the Agilent 1220 Infinity Mobile LC

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

Nonnutritive Sweeteners For Health Professionals

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

The Raptor HILIC-Si Column

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit

REBATEN. Great Taste Improvement of Stevia Sweetener DAEPYUNG

Ion Chromatography: A Versatile Technique for the Analysis of Beer

Evaluation of an LC-MS/MS Research Method for the Analysis of 33 Benzodiazepines and their Metabolites

Transcription:

Sensitive Analysis of Commonly Used Artificial and Natural Sweeteners Including Stevia and Their Impurities and Degradation Products Ian Acworth, Chris Crafts, and Bruce Bailey, Thermo Fisher Scientific, Chelmsford, MA, USA Abstract Many recently commercialized sweeteners tend to have increased potency, reducing the amount of active ingredient added to beverages and other food products and often providing cost savings to the manufacturer. Using increased potency has also contributed to a need for sensitive analytical methods to quantify the active product and to detect low levels of breakdown products and impurities, which are required for quality and safety issues. Because compounds typically do not possess any chromophore, traditional HPLC-UV approaches are inappropriate. The work in this study describes several methods using HPLC with the Thermo Scientific Dionex Corona Charged Aerosol Detector (CAD ) for the study of common natural sugars (fructose, glucose, turanose, saccharose, trehalose, maltose, melezitose, and raffinose); artificial sweeteners (sucralose, aspartame, saccharin, and acesulfame K); and newly introduced products containing stevia extracts (rebaudioside A and stevioside). These HPLC-CAD methods provide sensitivity at low levels (ng) with good reproducibility and accuracy, and correlation to the component concentrations. Stevia products were analyzed by both charged aerosol detection and UV. Charged aerosol detection showed a greater than fivefold improvement in sensitivity over UV for all major components. Finally, the UHPLC methods developed showed a decreased run time and an increased sensitivity for glucose, lactose, and sucrose. Typical limits of detection (LOD) were found to be <5 pg (on column) for glucose and other mono- and disaccharides. HPLC-CAD is a very flexible approach to measuring sweeteners and overcomes many of the limitations of UV, refractive index (RI), LC- MS, evaporative light scattering detection (ELSD), and HPLC-pulsed amperometric approaches. The HPLC-CAD platform can be used throughout the manufacturing process to ensure finished quality and batch-to-batch uniformity. Introduction The Dionex Corona CAD is a mass-sensitive universal detector for nonvolatile and some semivolatile analytes. Unlike absorbance, fluorescence, RI, or electrochemical detection, analyte response is independent of chemical structure. Carbohydrates lack chromophores and the typical approaches used for their analysis may lack sensitivity, require derivatization, or cannot be used with gradient. The work in this study examines different HPLC-CAD methods for the analysis of honey sugars, artificial sweeteners, and other natural products including stevia extracts. Finally, a new UHPLC method for fast analysis of simple carbohydrates is presented. The Corona CAD system is easy to use and offers a simple, sensitive, reproducible, and direct approach for the routine analysis of natural and artificial sweeteners. Artificial Sweeteners Global Method Column: ACE, C18 4.6 25 mm, 5 μm Mobile Phase: A) Deionized water B) Acetonitrile +.1% trifluoroacetic acid Gradient: 2 to 4% B over 25 min, 4 to 6% 25 3 min Flow Rate: 1. ml/min Inj. Volume: 5 μl Column Temp.: 3 C Samples: 1.2 to 2 μg on column FIGURE 1. Chromatogram of artificial sweeteners. 4 Norm. Acesulfame K Cyclamate Saccharin Sucralose Aspartame Neotame Alitame 5 1 15 2 25 3 35 26831 NHDC Dulcin

Universal Gradient Method for Artificial Sweeteners The sweetness of the several different artificial sweeteners commercially available ranges in potency from 3 to 13, times that of sucrose. Their chemical structure varies significantly as do their UV responses. The gradient method presented here is sensitive (easily measuring the low-level degradants and impurities). Unlike UV detection, all compounds give a similar response independent of chemical structure, thereby simplifying method development. This global method is a good starting point for the simultaneous analysis of artificial sweeteners with application to product development and quality control. Honey Sugars Method Column: Shodex Asahipak, NH2P-5 4E, 4.6 25 mm, 5 μm Mobile Phase: 7/3 (v/v) Acetonitrile, deionized water Flow Rate: 1. ml/min Inj. Volume: 1 μl Column Temp.: 35 C FIGURE 2. Chromatogram of honey sugars. Charged aerosol detection is more sensitive than RI and can be used with gradient chromatography. It measures compounds directly without the added complication of derivatization. Separation of carbohydrates using HILIC-based approaches extends the range of columns beyond the ion-exchange columns typically used with PAD. Eight carbohydrate standards commonly found in honey were analyzed (shown above at 1 μg on column each). The method was used to compare differences in forest, fir, and acacia honey samples. The LOD for simple sugar analysis is in the low ng levels on column. Splenda Method Column: Shodex Asahipak, NH2P-5 4E, 4.6 25 mm, 5 μm Mobile Phase A: Acetonitrile Mobile Phase B: Deionized water Gradient: 3% to 7% B in 4 min Flow Rate: 1. ml/min Inj. Volume: 1 μl Column Temp.: 3 C.18 Response 1 2 3 4 5 6 7 8 Peaks: 1. Fructose 2. Glucose 3. Turanose 4. Saccharose 5. Trehalose 6. Maltose 7. Melezitose 8. Raffinose FIGURE 3. Chromatogram of Splenda sweeteners..5 Volts Dextrose.45 1 Volts 2 3 4 5 6 78 9 1 11 Peaks: 1. Sucralose 2. Dextrose 3. Maltose 4. Maltotriose 5. Maltotetraose 6. Maltopentaose 7. Maltohexaose 8. Maltoheptaose 9. Maltooctaose 1. Maltononase 11. Maltodecaose.1 3 4 5 6 7 8 9 1 11 12 13 14 The traditional approaches used for the analysis of carbohydrates include RI, UV following derivatization, and pulsed amperometric detection (PAD). 26832 Sucralose 5 1 15 2 25 3 35 4 5 1 15 2 25 3 35 4 26833 2 Sensitive Analysis of Commonly Used Artificial and Natural Sweeteners Including Stevia and Their Impurities and Degradation Products

Gradient Analysis of Splenda Sweetener A packet of Splenda was dissolved in mobile phase A and diluted to obtain 1 μg of the sweetener on column. The gradient method enabled the separation of the active ingredient sucralose, the filler dextrose, and low levels of maltodextrins. All of these compounds are reported on the product packaging and must remain below government specified levels to be sold as a zerocalorie sweetener. As sucralose is so sweet, its relative abundance compared to the other ingredients in the product is low. The Dionex Corona CAD detector, with its wide dynamic range and sensitivity, is ideal for the routine measurement of product content and quality. Equal and an Unknown Impurity Method Column: Shiseido C18 SG3, 4.6 15 mm, 5 µm Mobile Phase: Acetonitrile, deionized water, trifluoroacetic acid (85:15:.5) Column Flow Rate: 1. ml/min Inj. Volume: 1 µl Column Temp.: 3 C FIGURE 4. Chromatogram of Equal sweeteners. Stevia Method Column: Shiseido Capcell PAK C18AQ, 4.6 25 mm, 5 μm Mobile Phase A: Deionized water, acetonitrile, trifluoroacetic acid (95:5:.1) Mobile Phase B: Acetonitrile, deionized water (95:5) Gradient: 5 to 9% B over 3 min Flow Rate: 1. ml/min Inj. Volume: 1 μl Column Temp.: 5 C The commercial use of the herb stevia contains extracts from the Stevia rebaudina, Bertoni plant. The two major glycosides stevioside and rebaudioside A (Reb A) and other minor glycosides (Reb B, C, and D) are resolved and detected by this method. Interestingly, several low level impurities are detected by the Dionex CAD detector, but not by UV at 21 nm. FIGURE 5. Selected portion of chromatogram of SweetLeaf Stevia extract at ~86 ng on column run with UV at 21 nm and CAD in series (top). Overlay of curves for Reb A and stevioside from ~5 to 1 ng on column each (bottom). Average of three injections, each fit to a linear correlation..6 Volts Dextrose and Maltodextrin Contaminant Aspartame.5 1. 1.5 2. 2.5 3. 3.5 4. 4.5 5. 5.5 6. 6.5 7. 26835 Detection of Unknown Peak in Equal Equal contains multiple components including the active ingredient, aspartame, along with the fillers dextrose and maltodextrin. All components were separated using reversed-phase chromatography and detected by the Dionex Corona CAD detector. During method development a trace impurity/ contaminant was found. Although several potential degradants (e.g., phenylalanine, aspartic acid) were analyzed, none corresponded to the impurity. 6 Response (peak area) -1 mau 14 12 1 8 6 4 2 Reb D 1 2 3 4 5 6 Mass on Column (ng) Rebaudioside: R 2 =.9986 Reb A Reb C Reb A Reb C Reb B -26 13 14 15 16 17 18 19 2 21 16 : R 2 =.9978 26834 3

Stevia Sweeteners Method Table 1. Samples of Sweeteners Used Product Distributor Classification Serving Size 1 Packet (g) Truvia Cargill, Inc. Table Sugar 3.5 5.9 Pure Via Whole Earth Sweetener Company Table Sugar 2 3.6 SweetLeaf Sweetener SweetLeaf Dietary Supplement 1 2.6 Stevia Extract (in the raw) Cumberland Packing Corp Dietary Supplement 1 1. Stevia Supreme Stevia Company, Inc. Dietary Supplement 1 1.1 Injection Conc. (mg/ml) SweetLeaf Stevia Extract Wisdom Natural Brands Dietary Supplement.25.86 FIGURE 6. Percentage of Reb A in stevia-containing products. Weight (Percent) 45% 4% 35% 3% 25% 2% 15% 1% 5% %.84% 1.37% 1.53% Truvia CAD UV PureVia 3.91% SweetLeaf Sweetener.68% Stevia "In the Raw" 4.4% Stevia Supreme 1.88% SweetLeaf Extract Analysis of Reb A in Stevia-Containing Products Leaves (Sigma) 26836 Although several stevia-containing products were sold as dietary supplements, it was not until late 28 that the FDA issued Generally Recognized As Safe (GRAS) affirmations for two commercial products to be sold as all natural, zero-calorie sweeteners: Truvia (Coca Cola) and Pure Via (Pepsi). The GRAS affirmation was for purified Reb A sweeteners only and not for products that contain the other glycosides found in the stevia leaf. The products listed in the table above were analyzed using the gradient charged aerosol detection method and the percent by weight of Reb A was determined. The data generated by UV at 21 nm and the Dionex CAD detector were comparable. However, the Dionex CAD has the advantage that all compounds are determined independent of chemical structure, whether a chromophore is present or not. The Dionex CAD detector is ideal for the measurement of trace contaminants and impurities. Sensitive Measurement of Stevia in Beverages Table 2. Means of Detection for Components Detector Limit of Detection (Mass On Column) Rebaudioside Isodeviol CAD 4 ng 4 ng 6 ng UV at 21 nm 65 ng 65 ng >9 ng The Dionex Corona CAD detector demonstrated greater sensitivity for all of the compounds of interest in the stevia evaluation. Limit of quantification (LOQ) was defined by a signalto-noise ratio 1. LOD was defined by a signal-to-noise ratio 3. 4 Sensitive Analysis of Commonly Used Artificial and Natural Sweeteners Including Stevia and Their Impurities and Degradation Products

FIGURE 7. Determination of caffeine (retention time 3.9 min) and five glycosides in a commercially available product. 1, 2.69 15 RebD RebA -2 13 14 15 16 17 18 19 2 RebC RebB Steviobioside Uhplc Carbohydrate Analysis Column: Waters BEH HILIC, 2.1 5 mm, 1.7 μm Mobile Phase: Acetonitrile/5 mm ammonium formate ph = 3 (91:9) Flow Rate: 1.8 ml/min Inj. Volume: 2 μl Column Temp.: 4 C Dionex Corona ultra Filter: Medium FIGURE 8. Comparison of picogram vs nanogram levels of carbohydrates. 42 5 pg on column 3.98 8.663 14.27 15.919 16.91 16.619 17.592 18.28 28 275 Glucose Sucrose Lactose 5 ng on column -2 5 1 15 2 25 26838 Analysis of Stevia in Soft Drinks The FDA GRAS declaration now permits the commercial production of stevia-based zero-calorie beverages. However, the Zevia company (Seattle, WA) began selling a line of alternative soft drinks with stevia early in 28 marketed as carbonated stevia supplements. The Zevia Natural Cola and the Zevia Natural Twist flavors were purchased and prepared by diluting 1 ml of each beverage with 5 ml methanol solvent prior to analysis. The content of Reb A was calculated to be.16% in both beverages with similar concentrations of stevioside. As shown in the chromatogram above (Zevia Natural Cola), caffeine is determined along with many unknown components. 55.5.1.15.2.25.3.35.4.45.5 26837 High Sensitivity and Rapid Analysis Figure 8 shows the separation of three common carbohydrates run under UHPLC-HILIC conditions. The method, using the Dionex Corona ultra detector, was rapid (<3 s) and could reproducibility detect <1 ng on column of the sugars. The LOD for glucose was estimated to be ~25 pg on column. Traditional HPLCbased platforms cannot maintain excellent analyte resolution with the rapid analysis of a nonchromophoric material. 5

Conclusion Both the Dionex Corona CAD and Dionex Corona ultra are extremely versatile detectors. The Dionex Corona ultra detector is fully compatible with UHPLC. As the Dionex Corona is a mass sensitive detector, with response being independent of chemical structure, a wide variety of compounds can be detected making it ideal for analysis of the many different compounds used in the food and beverage industry. Unlike RI detection, the Dionex Corona CAD can be used with gradient chromatography to improve speed and resolution. The sensitivity of the Dionex CAD detector (low ng on column) is greater than that of RI, approaches the sensitivity of PAD, and is about 1 more sensitive than UV at 21 nm. Subnanogram sensitivity can be achieved when UHPLC techniques are employed. The analysis of the major glycosides in stevia yielded similar data to UV, but due to its sensitivity and consistent inter-analyte response, it was capable of measuring trace impurities that were missed using UV detection. Acknowledgements Thermo Fisher Scientific is grateful to Dr. Mark Nightingdale (Durham County Council, UK) for giving his permission to use his data on the global analysis of artificial sweeteners. 211 Thermo Fisher Scientific, Inc. ACE is a registered trademark of Advanced Chromatography Technologies. Capcell PAK C18AQ is a registered trademark of Shiseido Company. Equal is a registered trademark of Merisant Company. Pure Via is a trademark of Whole Earth Sweetener Company. Splenda is a registered trademark of Tate and Lyle. SweetLeaf is a registered trademark of United American Industries Inc. Truvia is a registered trademark of Cargill Inc. Zevia is a trademark of Avakats LLC. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. This information is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Dionex Products: 1228 Titan Way, PO Box 363, Sunnyvale, CA 9488-363, (48) 737-7 North America: U.S./Canada (847) 295-75 South America: Brazil (55) 11 3731 514 Europe: Austria (43) 616 51 25, Benelux (31) 2 683 9768 (32) 3 353 4294 Denmark (45) 36 36 9 9, France (33) 1 39 3 1 1, Germany (49) 61125 991 Ireland (353) 644 64, Italy (39) 2 51 62 1267, Sweden (46) 8 473 338, Switzerland (41) 62 25 9966, United Kingdom (44) 1276 691722 Asia Pacific: Australia (61) 2 942 5233, China (852) 2428 3282, India (91) 22 2764 2735, Japan (81) 6885 1213, Korea (82) 2 2653 258, Singapore (65) 6289 119, Taiwan (886) 2 875 6655 www.thermoscientific.com/dionex LPN 2934-1 1/11