Cardiac Rhythm Therapy // Advanced Features // ProMRI. ProMRI. Checklist and Quick Reference Guide

Similar documents
Cardiac Rhythm Management // Manual // ProMRI. ProMRI. MR conditional device systems

MRI SureScan pacemakers & ICDs what you need to know

MRI for Patients with MRI-Conditional Pacing System: Radiographers Role. Lawrance Yip DM, DR, QMH

Micra MC1VR01. MRI procedural information for Micra Model MC1VR01 MR Conditional single chamber transcatheter pacing device (VVIR)

STANDARD OPERATING PROCEDURE (SOP)

MRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System

MRI imaging for patients with cardiac implantable electronic devices (CIEDs)

Advisa MRI and Ensura MRI SureScan pacing systems

MRI SURESCAN SYSTEMS. Patient Scanning Process PATIENT PRESCREENING. SureScan Pacing, Defibrillation, and CRT-D Systems Verification

EXAMPLE PROTOCOL FOR PATIENT SCANNING PROCESS

Call Medtronic at 1 (800) to verify the patient s current implanted system

MRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System

3/22/2017. MR Protocol Review Clinical Opportunities for Physicists. AAPM Newsletter March/April Technical to Clinical Transition - How?

MRI GUIDELINES FOR INSPIRE THERAPY

MRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System

IMAGEREADY MR CONDITIONAL PACING SYSTEM

CARDIAC DEVICE MR-CONDITIONAL PRODUCT SUMMARY CHART

MRI and CIEDs. Disclosures

ENABLE MRI CLINICAL STUDY SUMMARY

MRI in Patients with Pacemakers and Defibrillators. Paul A. Friedman, MD Win K Shen, MD Robert E. Watson, Jr. MD, Phd October 2016

MRI GUIDELINES FOR INSPIRE THERAPY

Q & A: How to Safely Scan Patients with a SureScan MRI Pacemaker

Supplemental Material

*smith&nephew. MRI Safety Information & Parameters for Smith & Nephew Orthopaedics AG. Knee Implants

Version überholt. Nicht verwenden. Version obsolète. Ne pas utiliser. Versione obsoleta. Non utilizzare. Verouderde versie. Niet gebruiken.

Managing Metallic Artifacts in MRI

Flowchart for ICD patients undergoing Surgery or procedures involving diathermy/magnetic fields

*smith&nephew. MRI Safety Information & Parameters for Smith & Nephew Orthopaedics AG. Shoulder Implants

VNS Therapy System Physician s Manual

UnitedHealthcare Medicare Advantage Cardiology Prior Authorization Program

MRI Exams in Patients with Non MR Conditional Pacemakers and with MR Conditional Pacemakers

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500)

NEIL CISPER TECHNICAL FIELD ENGINEER ICD/CRTD BASICS

Cochlear Implants. Medical Procedures. for MED EL Implant Systems. AW33290_2.0 (English US)

Initial Experience with a Radiologist-Managed MR Imaging Cardiac Pacemaker Program in an Academic-Affiliated Community Hospital

SJM MRI ACTIVATOR HANDHELD DEVICE WORKFLOW Model: EX4000. SJM-EDTR Item approved for U.S. use only.

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500)

Cochlear Implants. Medical Procedures. for MED EL CI Systems. AW33290_5.0 (English US)

Yes, out of sight out of mind.

Peri-operative management of pacemakers and implantable cardiac defibrillators

Warning: Patients should not be exposed to MRI environments until the surgical site following pump implantation is fully healed.

Model 5392 EPG Temporary Pacer

UnitedHealthcare, UnitedHealthcare of the River Valley and Neighborhood Health Partnership Cardiology Notification and Prior Authorization Program:

Magnetic resonance imaging in patients with cardiac implantable electronic devices

MRI conditional devices. A luxury or a real clinical need? Sophie Mavrogeni, MD, FESC Onassis Cardiac Surgery Center, Athens, Greece

Algovita. MRI Procedure Guidelines. Spinal Cord Stimulation System. 201x

Read this manual before performing an MRI scan on a patient implanted with an Algovita Spinal Cord Stimulation System.

MRI Guidelines for the Axonics Sacral Neuromodulation System

Implantable Cardioverter Defibrillators (ICD) - Medical Devices Pipeline Assessment, 2016

Devices and EP- Safety in MRI

Inventra 7. VR-T, VR-T DX, DR-T, HF-T, HF-T QP (ProMRI ) ICD-Family Tachyarrhythmia Therapy Cardiac Resynchronization Therapy.

2009 CPT Codes for Cardiac Device Monitoring

Τεχνολογικές εξελίξεις & καινοτοµίες στις συσκευές βηµατοδότησης & απινίδωσης

HAZARD ALERT. Important Medical Device Advisory. Premature Battery Depletion with Implantable Cardioverter Defibrillator

BIOTRONIK Clinical Studies IMPACT Clinical Study Patient Information. IMPACT Clinical Study: Patient Information Guide

Procedure for exceptional magnetic resonance scanning in patients with standard (non-mr-conditional) pacemakers

Pediatric pacemakers & ICDs:

INTERPRETING THE ECG IN PATIENTS WITH PACEMAKERS

Rivacor 3/5/7. ProMRI. ICD Family Tachyarrhythmia Therapy Cardiac Resynchronization Therapy. Technical Manual. Revision: C

8/2/2017. Acknowledgement. Disclaimer. How to manage radiotherapy patients with CIED from initial consult to treatment: TG203 recommendations

Is This Thing Working?

Intica 5/7 ProMRI. ICD-Family Tachyarrhythmia Therapy Cardiac Resynchronization Therapy. Technical Manual. Revision: D ( )

MRI ACCESS. Evera MRI SureScan ICD Systems

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System

Etrinsa 6 SR(-T), DR(-T), Etrinsa 8 SR-T, DR-T; HF-T (ProMRI )

Implant Procedure Concepts

MRI Checklist for MED EL CI and ABI models

How to set up a device clinic for heart failure patients Dr C Sridevi

*smith&nephew. MRI Safety Information & Parameters for Smith & Nephew Orthopaedics AG. Hip Implants

North America Cardiac Rhythm Management (CRM) Procedures Outlook to 2021

Leadless Pacing. Osama Diab Assistant Prof. of Cardiology Ain Shams University Egypt

PERIOPERATIVE MANAGEMENT: CARDIAC PACEMAKERS AND DEFIBRILLATORS

Pacing and Device Jargon Made Simple. Dr Jonathan Timperley MB ChB MD FRCP Consultant Cardiologist Northampton General Hospital

Cardiovascular magnetic resonance with an MR compatible pacemaker

UnitedHealthcare, UnitedHealthcare of the River Valley and Neighborhood Health Partnership Cardiology Notification and Prior Authorization Program:

How to prevent unecessary right ventricular pacing

Accessing Battery Information. Status symbol. Figure 1. Summary Dialog screen. Figure 2. Battery Status screen of a TELIGEN ICD 1

Cardiac Rhythm Device Management. PBL STOP Your acronym for a standardized follow-up

ImageReady MRI Head Only Guidelines for Spectra WaveWriter Spinal Cord Stimulator System

Idova 7. VR-T, VR-T DX, DR-T, HF-T (ProMRI ) ICD Family Tachyarrhythmia Therapy Cardiac Resynchronization Therapy.

Dual-Chamber Implantable Cardioverter-Defibrillator

EnTrust D154VRC Single Chamber ICD 35J delivered 8 seconds BOL, 11.8 seconds ERI 10.7 years**** 35cc, 68g Programmable Active Can

EHRA Accreditation Exam - Sample MCQs Cardiac Pacing and ICDs

ENGINEERED TO ENABLE THE FUTURE OF CONNECTED HEALTH

Solara CRT-P MRI SureScan W1TR06

11 YEARS PROVEN PERFORMANCE. Sprint Quattro Defibrillation Leads

Percepta CRT-P MRI SureScan W1TR01

MRI Safety Information for the HiRes Ultra 3D Cochlear Implant

Tachycardia Devices Indications and Basic Trouble Shooting

Leadless pacing. P.E. Vardas Professor of Cardiology University of Crete, Greece

Heart Rhythm Congress 2016 Chronotropic incompetence in heart failure patients

ImageReady MRI Full Body Guidelines for Precision Montage MRI Spinal Cord Stimulator System

Cigna - Prior Authorization Procedure List Cardiology

Size (mm) (H W D) Mass (g) Volume (cc)

Clinical Case 1 A patient with a syncope Panos E. Vardas President Elect of the ESC, Prof of Cardiology, University Hospital of Crete

Newer pacemakers also can monitor your blood temperature, breathing, and other factors and adjust your heart rate to changes in your activity.

12 YEARS PROVEN PERFORMANCE. Sprint Quattro Defibrillation Leads

His Bundle Pacing in Bundle Branch Block May 11, 2017

Magnetic resonance imaging of pacemakers and implantable cardioverter-defibrillators without specific absorption rate restrictions

PACING SYSTEMS.

Transcription:

Cardiac Rhythm Therapy // Advanced Features // ProMRI ProMRI Checklist and Quick Reference Guide

PAGE 2

Conditions for MR scans with a BIOTRONIK ProMRI system Usage of an MR scan on a patient having an implanted pacemaker (single- or dual-chamber), ICD, or CRT-D is only possible under highly specific prerequisites and conditions. BIOTRONIK offers a comprehensive, breakthrough portfolio of device systems approved for MR scans. These products are marked as ProMRI. Please use the matrix on the last page of this brochure or the BIOTRONIK ProMRI System Technical Manual to check whether the patient s ProMRI device-lead combination is approved for full body MR scans. The requirements listed in this guide apply to all ProMRI systems. PAGE 3

Conditions for MR scans with a BIOTRONIK ProMRI system (continued) Restrictions for the patient and the cardiac device system The device system consists of a pacemaker, ICD, or CRT-D with the respective leads that are separately labeled MR conditional and, when combined, constitutes an MR conditional device system (See charts on p. 10). There are no other active or abandoned cardiac implants (e.g., lead extensions, lead adapters or abandoned leads) in the patient s body. Other active or passive implants are permitted if they are identified as MR conditional by the manufacturer. Note: An MRI scan is permitted only if the product-specific conditions are met for all implants and if no metal implantable device longer than 5 cm is in the vicinity of a BIOTRONIK lead within a distance of less than 4 cm. The leads have been implanted for at least 6 weeks. The device system is implanted pectorally. The measured pacing threshold is not above 2.0 V at 0.4 ms pulse width. The device system should be functioning normally prior to an MRI. The battery status is neither ERI nor EOS. The device is programmed to an MRI mode immediately before the MR scan. PAGE 4

Conditions for MR scans with a BIOTRONIK ProMRI system (continued) Requirements of the MRI scanner Use of a clinical MRI machine with: A closed tube Cylindrical magnets A static magnetic field strength of 1.5 tesla. The slew rate of the MRI scanner s gradient fields should not exceed 200 T/m/s per axis. Restrictions during the MRI scan The MR scan should be performed with the patient in supine position. The mean specific absorption rate (SAR) for the whole body displayed by the MRI scanner must not exceed 2.0 W/kg. The head absorption rate displayed by the MRI scanner must not exceed 3.2 W/kg. Emergency equipment for resuscitation must be kept at hand and properly certified staff must be available. Continuously monitor the patient s condition during the entire MR scan using at least one of the following parameters: blood oxygen saturation, blood pressure or ECG. Note: The ECG function integrated in the MRI scanner is often not permitted for patient monitoring. Therefore, only use devices which are permitted for patient monitoring in an MRI environment. PAGE 5

ProMRI checklist for the radiology department Checklist before MRI scanning This checklist will help to ensure the safe application of an MR scan on patients with a BIOTRONIK device system that has been labeled MR Conditional. * We recommend checking the boxes off while using this checklist to ensure that an MR Conditional scan with BIOTRONIK ProMRI systems is permissible. Please check to see whether the patient s ProMRI device-lead combination is approved for a full body MR scan. (See charts on p. 10.) General requirements for patients with ProMRI systems Use of a clinical MRI system with a closed tube, cylindrical magnets and a static magnetic field strength of 1.5 tesla. The slew rate of the MRI scanner s gradient fields should not exceed 200 T/m/s per axis. The MR scan should be performed with the patient in supine position. The mean specific absorption rate for the whole body displayed by the MRI scanner must not exceed 2.0 W/kg. The head absorption rate displayed by the MRI scanner must not exceed 3.2 W/kg. Emergency equipment for resuscitation must be kept at hand and properly certified staff must be available. PAGE 6

ProMRI checklist for the radiology department (continued) The patient should be continiously monitored in an appropriate manner during the entire MR scan. The following parameters can be observed: blood oxygen saturation, blood pressure, ECG. Note: The ECG function integrated in the MRI scanner is often not permitted for patient monitoring. Therefore, only use devices which are permitted for patient monitoring in an MRI environment. Ensure with the cardiology department that the device is programmed to MRI mode prior to the MR scan. Name and signature Date * Details on these conditions and requirements can be found in the BIOTRONIK ProMRI System Technical Manual. Or, contact your local BIOTRONIK representative and visit www.biotronikusa.com/promri. PAGE 7

ProMRI checklist for the cardiology department Use the following checklist to ensure that patients who have been implanted with a BIOTRONIK device system labeled MR Conditional can receive an MR scan safely. * We recommend that you check off the boxes in order to be certain that a full body MR Conditional scan with BIOTRONIK ProMRI systems is permissible. Patient Name Address City Cardiac device system (please complete) Device * Detailed information about ProMRI can be found in the BIOTRONIK ProMRI System Technical Manual. You can download this document as a PDF file from the website: www.biotronikusa.com/manuals. Alternatively, contact your local BIOTRONIK representative and visit the website www.biotronikusa.com/promri. PAGE 8

ProMRI checklist for the cardiology department (continued) The device system consists of a pacemaker, ICD, or CRT-D with the respective leads that are separately labeled MR conditional and, when combined, constitutes an MR conditional device system (See charts on p. 10). There are no other active or abandoned cardiac implants (e.g., lead extensions, lead adapters or abandoned leads) in the patient s body. Other active or passive implants are permitted if they are identified as MR conditional by the manufacturer. Note: An MRI scan is permitted only if the product-specific conditions are met for all implants and if no metal implantable device longer than 5 cm is in the vicinity of a BIOTRONIK lead within a distance of less than 4 cm. The leads have been implanted for at least 6 weeks. The device system is implanted pectorally. The measured pacing threshold is not above 2.0 V at 0.4 ms pulse width. The device system should be functioning normally prior to an MRI. The battery status is neither ERI nor EOS. Ensure that the device is programmed to an MRI mode immediately before the MR scan and reprogrammed to the initial settings after the scan. Post MR scan requirements met (See p. 10). Name and signature Date * Details on these conditions and requirements can be found in the BIOTRONIK ProMRI System Technical Manual. Or, contact your local BIOTRONIK representative and visit www.biotronikusa.com/promri. PAGE 9

Post MR scan requirements The patient must undergo follow-up device interrogation, which is necessary for the patient s safety for two reasons: To reprogram device to original pacing parameters. To access the device system for any adverse effects caused by the MR scan. ProMRI system check Pacemakers Bradycardia Devices Eluna DR-T Entovis DR-T Eluna SR-T Entovis SR-T Setrox 60 Setrox 53 Siello S 45 DX ICDs Siello S 53 Siello S 60 Solia S 45 Solia S 53 Solia S 60 Linox smart S DX 65/15 Linox smart S DX 65/17 Tachycardia Devices Iperia VR-T DX Inventra VR-T DX Iforia VR-T DX PAGE 10

DR-T DF-1 ICDs Tachycardia Devices Iperia DR-T (DF-1) Iforia DR-T (DF-1) Setrox 53 Siello S 45 Siello S 53 Atrial Siello S 60 Solia S 45 Solia S 53 Solia S 60 RV Linox smart S 65 Linox smart SD 65/18 DR-T DF-4 ICDs Tachycardia Devices Iperia DR-T (DF4) Iforia DR-T (DF4) Setrox 53 Siello S 45 Siello S 53 Atrial Siello S 60 Solia S 45 Solia S 53 Solia S 60 PAGE 11 Continued >

DR-T DF-4 ICDs (continued) Tachycardia Devices Iperia DR-T (DF4) Iforia DR-T (DF4) Protego S 65 Protego S 75 RV Protego SD 65/16 Protego SD 65/18 Protego SD 75/18 HF-T DF-1 CRT-Ds Tachycardia Devices Iperia 7 HF-T (DF-1) Inventra 7 HF-T (DF-1) Atrial Setrox S 53 Linox smart S 65 RV Linox smart SD 65/18 Corox OTW 75 BP Corox OTW 85 BP Corox OTW-L 75 BP LV Corox OTW-L 85 BP Corox OTW-S 75 BP Corox OTW-S 85 BP PAGE 12

HF-T DF4 CRT-Ds Tachycardia Devices Iperia 7 HF-T (DF4) Inventra 7 HF-T (DF4) Atrial Setrox S 53 Protego S 65 Protego S 75 RV Protego SD 65/16 Protego SD 65/18 Protego SD 75/18 Corox OTW 75 BP Corox OTW 85 BP Corox OTW-L 75 BP LV Corox OTW-L 85 BP Corox OTW-S 75 BP Corox OTW-S 85 BP PAGE 13

ProMRI Checklist and Quick Reference Guide www.biotronikusa.com/promri BIOTRONIK, Inc. 6024 Jean Road Lake Oswego, OR 97035-5369 (800) 547-0394 (24-hour) (800) 291-0470 (fax) www.biotronik.com M4186-C 06/16 2016 BIOTRONIK, Inc. All rights reserved. BR316r2 6/10/16