NOAA Scientific Computer System (SCS version 4.0) INMARTECH 2006 SCS Presentation October 17, 2006

Similar documents
UHDAS and CODAS: Raising the Profile of Ocean Currents

RVTEC 2010 UHDAS/ADCP

Institute of Marine Research

Data Management System (DMS) User Guide

Lionbridge Connector for Hybris. User Guide

Data Management System (DMS) User Guide

Proteome Discoverer Version 1.3

Elemental Kinection. Requirements. 2 May Version Texas Christian University, Computer Science Department

UHDAS ADCP data Acquisition and CODAS processing

DPV. Ramona Ranz, Andreas Hungele, Prof. Reinhard Holl

Dosimeter Setting Device

AudioConsole. User Guide. Doc. No EN/01 Part No EN

Instructor Guide to EHR Go

Customer Guide to ShoreTel TAPI- VoIP Integrations. March

Data Management System (DMS) User Guide

Dosimeter Setting Device System NRZ

Content Part 2 Users manual... 4

Figure 1: The EVH board

Publishing WFS Services Tutorial

Data processing software for TGI/TGE series

Cleaning Up and Visualizing My Workout Data With JMP Shannon Conners, PhD JMP, SAS Abstract

TMWSuite. DAT Interactive interface

Dexcom CLARITY User Guide For Clinics

For Electric Personal Dosimete Dose-i

Senior Design Project

Affinity 2.0 integrated fitting solution. Audiometry, REM, HIT, and Visible Speech Mapping

ISS National Laboratory Initiative IRAD-1. UTC Contract Work. Lab-Like Architecture and Software Toolset Development

Clay Tablet Connector for hybris. User Guide. Version 1.5.0

CALYPSO Highlights

Introduction. What s new in Genie 2?

MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager

Figure 1: EVKT-MACOM with EVMA-CONN Daughter Board

Qualys PC/SCAP Auditor

Sleep Apnea Therapy Software Clinician Manual

Automated process to create snapshot reports based on the 2016 Murray Community-based Groups Capacity Survey: User Guide Report No.

SHORETEL APPLICATION NOTE

Manual Neon 2000 Family Neon Remote Terminals (NRT) 2017F Ethernet Family

Therapy Management Software for Diabetes

Sanako Lab 100 STS USER GUIDE

Student Orientation 2010, Centricity Enterprise EMR Training, and netlearning.parkview.com Instructions for Nursing Students

Internet Hub WLAN/3G/4G. Internet Cloud. Figure 1: U-Healthcare system overview

Release Notes. Medtech32. Version Build 3347 Update HbA1c Laboratory Data Format Change Advanced Forms Licensing Renewal (September 2011)

Dexcom CLARITY User Guide For Clinics

User Manual. RaySafe i2 dose viewer

Dexcom CLARITY User Guide

Note: This document describes normal operational functionality. It does not include maintenance and troubleshooting procedures.

Experiment HE-12: Targeted Exercise with Wireless Electrocardiogram (ECG)

Introduction. What s new in Genie 2? New Fitting features. Support for new hearing aids:

OneTouch Reveal Web Application. User Manual for Healthcare Professionals Instructions for Use

Exercise Pro Getting Started Guide

Real-time ECG monitoring system for the assessment of rural cardiac patients

Dexcom CLARITY User Guide For Clinics

Chapter 9. Tests, Procedures, and Diagnosis Codes The McGraw-Hill Companies, Inc. All rights reserved.

Phonak Target 4.3. Desktop Fitting Guide. Content. March 2016

Equinox 2.0. PC-based audiometer. Time saving solutions. Interacoustics. leading diagnostic solutions

Equinox 2.0 PC-based audiometer. Not just an audiometer - A full counseling and reporting solution

Lesson 3 Profex Graphical User Interface for BGMN and Fullprof

ECG Signal Based Heart Disease Detection System for Telemedicine Application Using LabVIEW

LiteLink mini USB. Diatransfer 2

Fitting System Instructions for Use

Aer ODE B3-20. Database System for GEX B3 Dosimetry. Aérial. Optical Dosimetry Equipment. (gamma and/or electron beam versions)

Fujitsu LifeBook T Series TabletPC Voluntary Product Accessibility Template

DICOM Conformance Statement

GST: Step by step Build Diary page

CNV PCA Search Tutorial

38 Int'l Conf. Bioinformatics and Computational Biology BIOCOMP'16

AC40. The true clinical. hybrid

Overview 6/27/16. Rationale for Real-time Text in the Classroom. What is Real-Time Text?

instadose dosimeters Dosimetry Services Division

User s Manual for Eclipse(AccuCap)

Lightened Dream. Quick Start Guide Lightened Dream is a dream journal designed to wake you up in your dreams.

Interact-AS. Use handwriting, typing and/or speech input. The most recently spoken phrase is shown in the top box

How-To Evaluate a Veterinary Digital Radiography System A SPECIAL REPORT

Interpreting the charts & graphs

Medtech32 Diabetes Get Checked II Advanced Form Release Notes

Sleep, Optimized. Accurate multistage sleep tracking for a new level of personal performance

Omnitest : 2013

Cross-Domain Development Kit XDK110 Platform for Application Development

User Guide. Association analysis. Input

University of Toronto. Final Report. myacl. Student: Alaa Abdulaal Pirave Eahalaivan Nirtal Shah. Professor: Jonathan Rose

Note: This document describes normal operational functionality. It does not include maintenance and troubleshooting procedures.

Your Fitness. Connected.

Table of Contents. Contour Diabetes App User Guide

Welch Allyn ABPM 6100S. Comprehensive blood pressure monitoring that brings patient comfort home.

ONE MONITORING SOLUTION TO MEASURE MORE. Zephyr Performance Systems for academics and researchers

CALYPSO 2017 Software Download Portal.

Graphical User Interface for Windows for MCM Module

Section Web-based Internet information and applications VoIP Transport Service (VoIPTS) Detail Voluntary Product Accessibility Template

User s Manual for ProCAT

Abbott FreeStyle Libre Pro System

WFS. User Guide. thinkwhere Glendevon House Castle Business Park Stirling FK9 4TZ Tel +44 (0) Fax +44 (0)

Data Management, Data Management PLUS User Guide

Contour Diabetes app User Guide

Epilepsy Sensor Transmitter

ECDC HIV Modelling Tool User Manual

Cisco Unified Communications Accessibility Innovation

ECDC HIV Modelling Tool User Manual version 1.0.0

The innovative intercom solution

Report reference guide. mmol/l. One. solution EMR. No fuss

Transcription:

NOAA Scientific Computer System (SCS version 4.0) INMARTECH 2006 SCS Presentation October 17, 2006

NOAA Scientific Computer System SCS Definition: A shipboard data acquisition system used to collect environmental, oceanographic and fisheries sensor data in real time.

SCS Primary Functions Acquire real time sensor data Log raw data to disk Monitor incoming data for errors Display real time data in text and graphical formats Output data to remote PCs (serial and socket) User-configurable Event Data Logging QA Post Processing of ASCII data set Auto-Mailing of summary data (SAMOS and Shiptracker) End of cruise data products

SCS 4.0 Data Flow Navigation Sensors Sensor Configuration File Real Time Displays Oceanographic Sensors Meteorological Sensors Sensor Device Objects Acquisition ACQ Data Server Real Time Gauges Real Time Plots Fisheries Sensors Quality Assurance Plots Post Processed GIS Trackline Data Logging (Raw Sensor Messages) Data Quality Checks SCS Web Server Web Displays + Graphs Real Time GIS Trackline Event Logging Send SCS Messages

SCS System Development Life Cycle Design and Development SCS 1986-1988 SCS v1.0 DEC MicroVax FORTRAN 200k + Lines of Code 3 vessels 1989-1992 SCS v2.0 VAX Workstations GUI+FORTRAN + C 150k + Lines of Code 5 Vessels 1993-1998 SCS v3.0 Windows (NT- >XP) C++ 116k Lines of Code 6 to 26+ Vessels 1999-2004 SCS v4.0 Windows (Xp+) C# + ASP + Web 125k lines of code More Vessels... 2005- Future

The Rationale for SCS 4.0 SCS 3.0 operation for 6+ years SCS 3.x limited expansion potential Microsoft.NET replaced Win32 API New Network Sensor Types emerging Web Centric Applications emerging FSCS 2.0 compatibility Improved Maintenance and reiability Re-vitalize Graphics Enhance GIS connectivity

SCS 4.0 Sensor Definitions NMEA sentence label extenders TCP/IP and UDP sensor types Calibrator sensors no longer supported. Enhanced Derived Sensor Types Translate message codes to plain text Disable/Enable Sensors easily Internal/External sensor simulation with real data Device Object -> > Parent Sensor -> > Child Sensors Architecture Supports Enhanced Sensor Control

SCS 4.0 ACQ Data Server ACQ Isolated by XML data Server Client and server talk in plain text XML Packet formatting standard. All Clients talk to ACQ via TCP/IP Sockets Easy for future apps to ask ACQ for data Usable.NET DLLs for talking to SCS available

SCS 4.0 Data Logging Simultaneous Dual System Logging All Raw Message Data Logged On demand Compress and Lab files Identical Format to SCS 3.x Event Logger file Formats Identical Specialized Site Event Logger Designed for tracking Station/Site Events Directly connects to database

Event Logger Provides scientists with personalized/ customized data logging Allows metadata to be associated with each event (i.e. vessel, cruise#, etc ) Event buttons provide for annotation while the event is running Several events can be run simultaneously Event Logger re-written for stability

SCS 4.0 Graphic Displays Dundas-Chart used for time series plots. Time Series (4 sensors on 2 axis) XY Plots Dundas-Gauge used for gauge displays. Customizable Gauges for easy viewing Instrument Panels of Mixed Gauges 50 plus Gauge templates available Dundas-Chart ASP used for time series plots on Web Time Series (4 sensors on 2 axis) XY Plots

SCS 4.0 - GIS New track line plot app based on ESRI GIS software library. Can track ship and towed body simultaneously. Can display data in ESRI Shape files, Grids and Coverages. Can write track line data as Shape file. Tracklines can overlay imagery layers. Overlay historic tracklines from RAW files Extensible

SCS 4.0 Web Service Web browser connections to Dedicated SCS Web Service Provides Web Text Displays Provides Web Time Series Plots Provides Web Logging Status Display Provides Sensor Configuration Listings Extensible in the future by Users/ NMAO

SCS Installations Typical SCS Server (Dell Poweredge 2850) (DIGI Acceleport) serial ports SCS uses less than 3% of CPU PC Laptop (1Ghz+) Windows XP Edgeport USB serial Ports Or Network Serial Ports

SCS 4.0 Installation Wizard

SCS 4.0 Data Flow Navigation Sensors Sensor Configuration File Real Time Displays Navigation Sensors Navigation Sensors Sensor Device Objects Acquisition ACQ Data Server Real Time Gauges Real Time Plots Navigation Sensors Quality Assurance Plots Post Processed GIS Trackline Data Logging (Raw Sensor Messages) Data Quality Checks SCS Web Server Web Displays + Graphs Real Time GIS Trackline Event Logging Send SCS Messages

SCS 4.0 ACQ Main Window

ACQ Logging Status

ACQ Real Time Monitor All sensors or just parents Status LEDs Sort in any column

Data Monitoring/QA Range Checks Delta Checks Synch Checks Sensor Timeouts

SCS 4.0 Real Time Display

Real Time Displays/Gauges Provides basic visualization of real-time data Displays are user-configurable Visual indication when data fails to update User Configurable Instrument Panels

SCS 4.0 Gauge Displays

SCS 4.0 Real Time Series Plot

SCS 4.0 GIS Track Line Plot

Sets value of The User Disk File Metaitem Is Written To Output COM port Presses Socket ACQ Sensor Sets value of Updates Value Of Button Starts or Stops Starts or Stops Presses Monitors Value Of Monitor Starts or Stops Plays Alarm WAV file Speaker

SCS 4.0 Event Builder

SCS 4.0 Event Logger

SCS 4.0 Web Access

SCS Web Interface Sensor Descriptions Web Pages Real Time Data Displays Web Pages SCS ACQ Data Server SCS Web Service Loggign Stats Web Pages Post Time Series Plots Web Pages Real Time Gauges Web Pages

SCS Web (Sensor Descriptions)

Web SCS Logger Status

Web Displays Based on Window Displays

SCS Data Web Display

SCS Brief Data Display

Web Post Time Series Plot

SAMOS Mailer Shipboard data transfer Automated Quality Assurance Unobtrusive Easy to install/run Requires SCS 4.0

EventBuilder SAMOS Event File SAMOS Mailer - DFD Eventlogger SAMOS Event Must run the SAMOS Event continuously. Header File Data file MetaData File Wakes every 24 hours to process the latest dataset. SAMOS Mailer Mail

SAMOS Mailer - Eventlogger Relies extensively on Eventlogger features of SCS 4.0 Dedicated SAMOS Event

SAMOS Mailer - Eventlogger SAMOS Event must run continuously.

SAMOS Mailer - Eventlogger Header file output - *.hdr MetaData file output - *.csv Provides sensor to genre correlation.

SAMOS Mailer - Eventlogger Data file output - *.elg

SAMOS Mailer Customized formatting is applied to data output from Event. File is then compressed and mailed.

Overall SCS Advantages Simple to use Easy to manage Fast and easy to configure Stability (in use for over 10 years) Easy user-access to data Can be configured to use on any vessel without the need for new software modules

Vessels with SCS NOAA 13 ships w/ SCS w/integrated sensor suite 5 ships w/ SCS ShipTracker version (FA, RA, TJ, RU, CO) NOAA NWFSC charter vessels US Coast Guard Polar Star, Polar Sea, Healy Canadian Coast Guard Wilfred Laurier, John P. Tully, W.E. Ricker, Vector UNOLS Endeavor (URI), Weather Bird II (BBSR), Clifford A. Barnes (UW), Cape Hatteras British Antarctic Survey James Clark Ross, Ernest Shackleton State Fisheries Vessels Alabama, Mississippi, Louisiana, others??? JAMSTEC Marai SEACOOS Suncoaster Direct Support Indirect Support

Partnership Efforts Brookhaven National Labs International SeaKeepers Society British Antarctic Survey UNOLS US Coast Guard Canadian Coast Guard National Oceanographic Data Center (NODC) National Marine Fisheries (NMFS)