Rigel UNI-SiM. The world s smallest integrated NiBP, SpO2 and patient simulator. Key Features n Compact and cost-effective

Similar documents
Rigel UNI-SiM Lite. The most cost-effective patient simulator on the market. Key Features n Compact and cost-effective

ProSim 3 and 2. Vital Signs Simulators

ProSim 3 and 2 Vital Signs Simulators

MULTI-PARAMETER PATIENT SIMULATOR

ProSim 8. Users Manual. Vital Signs Simulator

Appendix D Output Code and Interpretation of Analysis

VITAL SIGNS MONITORING. RVS-100/200 ri-vital. Vital Signs Patient Monitors

Monitoring Equipment. Blood Pressure Monitor Upper Arm Type: Image (Image not to scale)

CARESCAPE Patient Data Module

ProSim 4 Vital Signs Simulator

ProSim 6/8. Users Manual. Vital Signs Simulator

CARESCAPE Patient Data Module

Defibrillators TEC-8300K series. Improving quality of resuscitation

ProSim 8 Vital Signs Simulator

Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing. D. J. McMahon cewood rev

Course Objectives. Proper Lead Placements. Review the ECG print paper. Review the mechanics of the Myocardium. Review basics of ECG Rhythms

The HeartCheck TM PEN Handheld ECG Is your heartbeat slow, fast, or irregular? Are you at risk? Put your heart health in your own hands

Vital Signs Simulator

TECHNOCARE MEDISYSTEMS

Cardiocap/5. GE Healthcare. The compact, all-in-one, critical care monitor. Features. Available options

QUICK SETUP GUIDE SECULIFE DFBASE

Multiparameter Simulation

OBJECTIVE. 1. Define defibrillation. 2. Describe Need and history of defibrillation. 3. Describe the principle and mechanism of defibrillation.

Testing the Accuracy of ECG Captured by Cronovo through Comparison of ECG Recording to a Standard 12-Lead ECG Recording Device

medsim 300B Patient Simulator

Panorama. Arrhythmia Analysis Frequently Asked Questions

Basic Dysrhythmia Interpretation

BP Pump 2. Non-Invasive Blood Pressure Simulator and Tester. Technical Data. Key features

Arrhythmia Study Guide 3 Junctional and Ventricular Rhythms

CRC 431 ECG Basics. Bill Pruitt, MBA, RRT, CPFT, AE-C

Defibrillators TEC-8300K series. It s all seamless

Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing

ECG MACHINE KEC- Series

Specified Tolerance (ms)

Step by step approach to EKG rhythm interpretation:

MPS450. Operators Manual. Multiparameter Simulator

ECG Interpretation. Introduction to Cardiac Telemetry. Michael Peters, RN, CCRN, CFRN CALSTAR Air Medical Services

INSTRUCTION MANUAL. phantom 320 ECG Simulator 1.4

MEDITRON SYSTEMS. Consumable & Accessories [Catalogue # 13]

91496-A B C I L. Summary

DEFIB «U S E-HEART. CardioStart MEDICAL MEDIO TECHNOLOGIES BIPHASIC DEFIBRILLATORS К-ИЕЛКГ. Wmwie

Infinity. Kappa XLT Patient Monitor. Because you care

-RHYTHM PRACTICE- By Dr.moanes Msc.cardiology Assistant Lecturer of Cardiology Al Azhar University. OBHG Education Subcommittee

Rhythm ECG Characteristics Example. Normal Sinus Rhythm (NSR)

Module 1: Introduction to ECG & Normal ECG

Indications The AED mode is to be used only on patients in cardiopulmonary arrest.

medsim 300B Operators Manual Patient Simulator

ECG ABNORMALITIES D R. T AM A R A AL Q U D AH

M Series with Rectilinear Biphasic Waveform Defibrillator Option Indications for Use

Basic EKG Interpretation. Nirja Parikh, PT, DPT

UNDERSTANDING YOUR ECG: A REVIEW

DEFIBRILLATORS ATRIAL AND VENTRICULAR FIBRILLATION

Electrocardiography for Healthcare Professionals

Arrhythmic Complications of MI. Teferi Mitiku, MD Assistant Clinical Professor of Medicine University of California Irvine

Neuro-MEP-Micro EMG EP. 2-Channel Portable EMG and NCS System with a Built-in Miniature Dedicated Keyboard. EMG according to international standards

Cardiology Flash Cards

Presented By: Barbara Furry, RN-BC, MS, CCRN, FAHA Director The Center of Excellence in Education Director of HERO

The ECG Course. Boone County Fire Protection District EMS Education

Please check your answers with correct statements in answer pages after the ECG cases.

CORONARY ARTERIES. LAD Anterior wall of the left vent Lateral wall of left vent Anterior 2/3 of interventricluar septum R & L bundle branches

ABCs of ECGs. Shelby L. Durler

EKG Competency for Agency

X Series Extensive Capabilities

Lab Activity 24 EKG. Portland Community College BI 232

SVT Discriminators. Definition of SVT Discrimination. Identify which patient populations might benefit from these features

Cardiac Arrhythmias in Sleep

ECG pre-reading manual. Created for the North West Regional EMET training program

EKG Rhythm Interpretation Exam

An introduction to measuring and simulating Vital Signs

Bedside Monitors BSM-6000 series

DEFIBRILLATORS. Prof. Yasser Mostafa Kadah

II. PROCEDURE DESCRIPTION A. Normal Waveform from an Electrocardiogram Figure 1 shows two cycles of a normal ECG waveform.

The Electrocardiogram part II. Dr. Adelina Vlad, MD PhD

Rate: The atrial and ventricular rates are equal; heart rate is greater than 100 bpm (usually between bpm).

Biomedical Signal Processing

KNOW YOUR ECG. G. Somasekhar MD DM FEp Consultant Electro physiologist, Aayush Hospital, Vijayawada

Patient Simulator. Instruction Manual. 04/2007, Peter Kron GmbH Subject to Technical Changes

ProSim 4. Users Manual. Vital Signs Simulator

2017 BDKA Review. Regularity Rate P waves PRI QRS Interpretation. Regularity Rate P waves PRI QRS Interpretation 1/1/2017

RN-BC, MS, CCRN, FAHA

The heart's "natural" pacemaker is called the sinoatrial (SA) node or sinus node.

Choosing Mindray SpO2

ECGs and Arrhythmias: Family Medicine Board Review 2009

Electrocardiography for Healthcare Professionals

EKG Abnormalities. Adapted from:

ECG Interpretation Cat Williams, DVM DACVIM (Cardiology)

ECG Interpretation Made Easy

Cardiac Arrhythmias. Cathy Percival, RN, FALU, FLMI VP, Medical Director AIG Life and Retirement Company

ECG interpretation basics

Dr.Binoy Skaria 13/07/15

AN AUTHENTIC ECG SIMULATOR. PAUL J. MICHALEK Bachelor of Science in Computer Engineering University of Central Florida, 2006

Electrical System Overview Electrocardiograms Action Potentials 12-Lead Positioning Values To Memorize Calculating Rates

Measures 100 ppm to 100% water content. Precision titrant delivery system. Anti-diffusion burette tip. Built-in stirrer

Pennsylvania Academy of Family Physicians Foundation & UPMC 43rd Refresher Course in Family Medicine CME Conference March 10-13, 2016

Study methodology for screening candidates to athletes risk

HTEC 91. Performing ECGs: Procedure. Normal Sinus Rhythm (NSR) Topic for Today: Sinus Rhythms. Characteristics of NSR. Conduction Pathway

AMPS-1. Advanced Modular Patient Simulator. Operating Manual

SURETEST Torque Calibration System

BEDSIDE ECG INTERPRETATION

Transcription:

Rigel UNI-SiM The world s smallest integrated NiBP, SpO2 and patient simulator. The UNI-SiM is a handheld and battery-operated vital signs simulator capable of undertaking six synchronized vital signs parameters. This enables medical device engineers to quickly, easily and accurately perform NiBP, SpO2, ECG, temperature, IBP and respiration functionality tests simultaneously, using a single portable instrument. With a fast boot up and single button simulation to repeat the last simulation value in seconds, the UNI-SiM reduces the time taken to test the correct performance of a wide range of medical devices and equipment. It is easy-to-use and incorporates the full functionality of conventional NiBP and SpO2 simulators with a comprehensive patient simulator. Compatibility with the Rigel PULS-R universal SpO2 simulation finger creates a truly versatile and valuable tool for every biomed engineer in need of a cost-effective and lightweight solution for testing the performance of vital signs monitors. Key Features n Compact and cost-effective n 6-in-1 vital signs simulation n Fast start up and single button simulation n Accurate and real-life simulations n User definable NiBP simulations n On-board automation and data storage n User programmable patient conditions n Universal SpO2 simulation with PULS-R n Easy and accurate probe placement with PULS-R Functions n NiBP (systolic and diastolic) n ECG n Respiration n SpO2 n IBP n Temperature End User Types BMETs requiring a cost-effective solution for carrying out performance checks and full PMs on vital signs monitors. Download your FREE introduction to measuring and simulating Vital Signs www.rigelmedical.com/guides

u Compact and cost-effective A highly cost-effective and compact solution for testing 6 of the most common vital signs using a single battery-powered simulator. 6-in-1 vital signs simulation The UNI-SiM incorporates full NiBP simulation including dynamic and static pressure simulation and leak and over-pressure testing with a comprehensive SpO2 and ECG simulator, all in a single hand-held enclosure. u Fast start up and single button simulation Automatic power-up of the most recent settings provides simulation of all 6 vital signs with the press of a single button, saving valuable time when setting up the simulator.

Accurate and real-life simulations Fully synchronized simulation signals provide the closest and most accurate representation of a real patient. u User definable NiBP simulations User configurable and physiologically correct systolic and diastolic pressures provide a truly universal and accurate NiBP simulator. On-board automation and data storage Simple record management for up to 5,000 asset records. The simulated values from the patient monitor can be entered directly into the UNI-SiM using the built-in keyboard, improving traceability and reducing the need for manual data recording.

u User programmable patient conditions Patient specific physiological conditions can be created and stored in the UNI-SiM to provide a highly customisable simulator. A truly versatile tool capable of meeting even the most demanding test protocols. Universal SpO2 simulation with PULS-R Reduce the need for separate accessories with the universal PULS-R SpO2 simulation finger. This compact SpO2 simulation enables accurate SpO2 simulations in 1% resolution from as low as 30%* using the pre-programmed manufacturer specific R-curves. * subject to monitor capability u Easy and accurate probe placement with PULS-R Unique probe placement LED s ensure accurate and correct simulation for each type of SpO2 probe. The Rigel PULS-R has status LEDs which light up to indicate whether a probe connection has been achieved.

Technical Specifications - UNI-SiM Non-Invasive Blood Pressure Waveform Oscillometric Pulse Volume High, Medium, Low, Paediatric 20-300BPM Integrated Pump 0 to 350mmHg user configurable Leak Test User configurable between 0-350mmHg Chronometer Configurable up to 999 secs Digital Manometer 0-410mmHg Pressure +/- 0.5% FS Pressure Units mmhg, inhg, kg/cm2, cmh2o, mbar, PSI, in H2O and kpa Oxygen Saturation (SpO2 Adapter boxes) Optronic (Electronic & Optical) via Probe & full chain Range 50 to 100% ± 0.5% of reading between 80-100% SpO2 ± 1% of reading between 50-79% SpO2 20-300BPM ± 1BPM Compatibility GE - Datex, Nellcor, N.Oximax, Masimo, Datascope, Mindray, Nonin, Philips (HP) Perfusion Index -20% (5% default) Chronometer Test option to test response time SpO2 monitor. Oxygen Saturation (PULS-R) Range 30 to 100% Repeatability ± 5%** of reading between 30-59% SpO2 ± 3% of reading between 60-99% SpO2 ± 3% of reading between 90-100% SpO2 of simulation when used with the corresponding R-curves *Based on using the same probe and monitor setup **Note that some monitor types might not be able to display low range sats Compatibility ***Subject to monitor capability ECG Arrhythmia Simulator 30-300BPM*** ± 1BPM Beijing Choice, Criticare, GE Tuffsat, Masimo, Mindray, Nellcor, Nellcor Oximax, Nihon Kohden, Nonin, Novametrix, Philips / HP Amplitudes ± 2% Connection High-Level ECG 3.5mm jack plug 5 lead simulation including high level output on Normal Sinus Rhythm (NSR), ST Elevation, ST Depression, Myocardial Infarcation, Tall T 20 300BPM ±1BPM 0.5 / 1 / 1.5 / 2 / 2.5 / 3 / 3.5 / 4 / 4.5 / 5mV ST Elevation / Depression 20 300BPM Elevation % 7%, 13%, 20% Elevation Slope Positive, Negative, Flat Myocardial Infarction Type Tall T T Wave Amplitude Ischemia, Injury, Infarction, Inferior Infarction 20 300BPM 80BPM 0 1.2mV (steps of 0.1mV) Arrhythmia Waveforms Full 12 lead simulation Amplitudes 0.5 / 1 / 1.5 / 2 / 2.5 / 3 / 3.5 / 4 / 4.5 / 5mV (where applicable)20 300BPM Atrial Sinus Arrhythmia (SA), Missing Beat, Atrial Flutter (AFLT), Atrial Fibrillation (AFB), Paroxysmal Atrial Tachycardia (PAT), Junctional Premature Contraction Atrial Conduction First Degree AV Block, Second Degree AV Block - Mobitz I, Second Degree AV Block - Mobitz II, Third Degree AV Block, Right Bundle Branch Block (RBB), Left Bundle Branch Block (LBB), Left Anterior Hemiblock Ventricular Premature Ventricular Contraction - Intermittent Premature Ventricular Contraction Continuous, Bigeminy, Trigeminy, Ventricular Flutter (VFLT), Ventricular Fibrillation Fine (VFBF), Ventricular Fibrillation Coarse (VFBC), Monomorphic Ventricular Tachycardia (MVT), Polymorphic Ventricular Tachycardia (PVT), Right Focal (PVC) Performance Waveforms Shape Sine, Square, Triangle, and Pulse Rates 0.1 to 0.9Hz (in steps of 0.1) 1 to 100Hz (in steps of 1) Amplitudes 0.5 / 1 / 1.5 / 2 / 2.5 / 3 / 3.5 / 4 / 4.5 / 5mV Pulse 1mV, 4 sec delay (20ms pulse duration) Pacer Waveforms Available QRS Pacer Pulse Amplitude Pacer Pulse Polarity Pacer Pulse Width R Wave Detection R Wave Width Synchronous Atrial, Asynchronous Atrial, Paver Only, Ventricular Pacer, Atrial & Ventricular Pacer 1mV 0.1 2mV Positive, Negative 0.1 2ms 70BPM 10 120ms (steps of 10ms) Temperature YSI 400 / 700 Static Range Preset at 25, 33, 37 and 41 C ± 0.1 C Default Setting YSI 400 37 C

Technical Specifications - UNI-SiM (Continued) Respiration Rates 5, 10, 15, 30, 60, 120, 180 Breaths per Minute Base Resistances 250, 500, 750, 1000Ω ± 5% Resistance Variations 0.1, 0.5, 1.0, 1.5Ω ± 10% Default Settings 15BPM / 250Ω / 0.1Ω Apnoea 0 60 seconds duration 0 300 seconds interval Invasive Blood Pressure Channels 2 channels Static 0 to 300mmHg Dynamic 0-300mmHg for Systolic & Diastolic ± 1mmHg Excitation Voltage 2 16V Impedance 350Ω Nominal Simulated Sensitivity 5μV / V / mmhg General Specifications - UNI-SiM Operation Battery cell, in-situ charge Battery Charger 100-240VAC, 50/60Hz Supply 12VDC centre positive Battery Life 8 hours standby or a maximum of 200 NiBP simulations Memory Capacity Approx. 5,000 records Communication via Bluetooth Display Monochrome, ¼ VGA full graphics Keypad Alpha-numeric Weight <1.5kg, <3.5lbs Size (L x W x D) 270 x 110 x 75mm / 10.5 x 4 x 3" Operating Conditions 10-30ºC, 0-90% RH - NC Storage Environment -15º - +60ºC Environmental Protection IP 40 Service & Warranty UNI-SiM comes with a free upgraded 24 month warranty (subject to terms and conditions, available at www.rigelmedical.com/register-product) Standard Accessories (supplied with UNI-SiM) n Carry case n ECG snap-on adaptors n NiBP tubing kit n Quick start guide n ECG adaptor module n Power supply Optional Accessories n IBP connect cables n NiBP accessories n Temperature connect cables n ECG cables and leads To find out more, visit www.rigelmedical.com/sim-accessories Specifications - PULS-R Supported Default R Curves Beijing Choice Criticare GE Tuffsat Masimo Mindray Nellcor Nellcor Oximax Nihon Kohden Nonin Novametrix Philips / HP Standard Accessories (supplied with PULS-R) PULS-R universal SpO2 simulation finger Quick Start Guide Setting 30-300BPM (subject to Monitor Compatibility) of when used with the Corresponding R Curves Resolution Range Repeatability* 1% steps 30-59% ±5%** 1% steps 60-89% ±3% 1% steps 90-100% ±1% Part Numbers UNI-SiM PULS-R 370A930 399A910 Rev 2, 2015 Technical specification subject to change without notice.