Durability and Outcome of Aortic Valve Replacement With Mitral Valve Repair Versus Double Valve Replacement

Similar documents
16 YEAR RESULTS Carpentier-Edwards PERIMOUNT Mitral Pericardial Bioprosthesis, Model 6900

CLINICAL COMMUNIQUE 16 YEAR RESULTS

Mitral Valve Repair Versus Replacement in Simultaneous Mitral and Aortic Valve Surgery for Rheumatic Disease

Hani K. Najm MD, Msc, FRCSC FACC, FESC President Saudi Society for Cardiac Surgeons Associate Professor of Cardiothoracic Surgery King Abdulaziz

Does Patient-Prosthesis Mismatch Affect Long-term Results after Mitral Valve Replacement?

Despite improvements in valve design, stroke remains a serious

Carpentier-Edwards Pericardial Valve in the Aortic Position: 25-Years Experience

Reoperation for Bioprosthetic Mitral Structural Failure: Risk Assessment

Outcomes of Mitral Valve Repair for Mitral Regurgitation Due to Degenerative Disease

Hani K. Najm MD, Msc, FRCSC, FRCS (Glasgow), FACC, FESC President of Saudi Heart Association King Abdulaziz Cardiac Centre Riyadh, Saudi Arabia.

Presenter Disclosure. Patrick O. Myers, M.D. No Relationships to Disclose

Expanding Relevance of Aortic Valve Repair Is Earlier Operation Indicated?

Approximately 40% to 60% of patients who undergo mitral valve

Although mitral valve replacement (MVR) is no longer the surgical

Department of Cardiothoracic Surgery, Heart and Lung Center, Lund University Hospital, Lund, Sweden

Kinsing Ko, Thom de Kroon, Najim Kaoui, Bart van Putte, Nabil Saouti. St. Antonius Hospital, Nieuwegein, The Netherlands

Ischemic mitral valve reconstruction and replacement: Comparison of long-term survival and complications

Effect of Valve Suture Technique on Incidence of Paraprosthetic Regurgitation and 10-Year Survival

Long-term results (22 years) of the Ross Operation a single institutional experience

15-Year Comparison of Supra-Annular Porcine and PERIMOUNT Aortic Bioprostheses

Clinical material and methods. Copyright by ICR Publishers 2003

ORIGINAL PAPER. The long-term results and changing patterns of biological valves at the mitral position in contemporary practice in Japan

The operative mortality rate after redo valvular operations

Surgical AVR: Are there any contraindications? Pyowon Park Samsung Medical Center Seoul, Korea

The use of mitral valve (MV) repair to correct mitral

The St. Jude Medical Biocor Bioprosthesis

P have been used for mitral and aortic valve replacement

THE IMPACT OF AGE, CORONARY ARTERY DISEASE, AND CARDIAC COMORBIDITY ON LATE SURVIVAL AFTER BIOPROSTHETIC AORTIC VALVE REPLACEMENT

Long term outcomes of posterior leaflet folding valvuloplasty for mitral valve regurgitation

Mitral valve repair is the procedure of choice in SURGERY FOR ACQUIRED CARDIOVASCULAR DISEASE

The CarboMedics prosthetic valve (Sulzer CarboMedics,

Which Type of Secondary Tricuspid Regurgitation Accompanying Mitral Valve Disease Should Be Surgically Treated?

Mechanical Tricuspid Valve Replacement Is Not Superior in Patients Younger Than 65 Years Who Need Long-Term Anticoagulation

Long-Term Results With the Medtronic-Hall Valvular Prosthesis

The clinical experience reported in recent Western series has provided

Clinical material and methods. Copyright by ICR Publishers 2007

Tissue vs Mechanical What s the Data??

TAVR 2018: TAVR has high clinical efficacy according to baseline patient risk! ii. Con

Sotirios N. Prapas, M.D., Ph.D, F.E.C.T.S.

Medtronic Mosaic porcine bioprosthesis: Assessment of 12-year performance

Indication, Timing, Assessment and Update on TAVI

The Changing Epidemiology of Valvular Heart Disease: Implications for Interventional Treatment Alternatives. Martin B. Leon, MD

Ann Thorac Cardiovasc Surg 2015; 21: Online April 18, 2014 doi: /atcs.oa Original Article

Χειρουργική Αντιμετώπιση της Ανεπάρκειας της Μιτροειδούς Βαλβίδας

A Surgeon s Perspective Guidelines for the Management of Patients with Valvular Heart Disease Adapted from the 2006 ACC/AHA Guideline Revision

Update on Oral Anticoagulation for Mechanical Heart Valves

Contemporary outcomes for surgical mitral valve repair: A benchmark for evaluating emerging mitral valve technology

T sors in the following aspects: the porcine aortic valve

CONTRIBUTION. Aortic valve replacement in young patients: long-term follow-up

Ten percent of patients with valvular heart disease have involvement

VALVE REPAIR VERSUS REPLACEMENT FOR MITRAL INSUFFICIENCY: WHEN IS A MECHANICAL VALVE STILL INDICATED?

Quality Outcomes Mitral Valve Repair

Surgical AF Ablation : Lesion Sets and Energy Sources. What are the data? Steven F Bolling, MD Cardiac Surgery University of Michigan

Ball Valve (Smeloff-Cutter) Aortic Valve Replacement Without Anticoagulation

Durability of Pericardial Versus Porcine Aortic Valves

Mechanical vs. Bioprosthetic Aortic Valve Replacement: Time to Reconsider? Christian Shults, MD Cardiac Surgeon, Medstar Heart and Vascular Institute

Mitral valve (MV) repair is preferred over replacement. Is Mitral Valve Repair Superior to Replacement in Elderly Patients?

Late failure of transcatheter heart valves: An open question

Influence of Atrial Fibrillation on Outcome Following Mitral Valve Repair

Incidence of prosthesis-patient mismatch in patients receiving mitral Biocor porcine prosthetic valves

Management of Difficult Aortic Root, Old and New solutions

The risk-benefit ratio of mitral valve operation is

Long-term Experience with the Bjork-Shiley Monostrut Tilting Disc Valve

Surgery for Acquired Cardiovascular Disease

Nineteen-Millimeter Aortic St. Jude Medical Heart Valve Prosthesis: Up to Sixteen Years Follow-up

For rheumatic mitral stenosis, percutaneous balloon

Mitral Valve Surgery: Lessons from New York State

Clinical Practice Guidelines and the Under Treatment of Concomitant AF Vinay Badhwar, MD

A 20-year experience of 1712 patients with the Biocor porcine bioprosthesis

Prof. Patrizio LANCELLOTTI, MD, PhD Heart Valve Clinic, University of Liège, CHU Sart Tilman, Liège, BELGIUM

Bicuspid aortic root spared during ascending aorta surgery: an update of long-term results

42yr Old Male with Severe AR Mild LV dysfunction s/p TOF -AV Replacement(tissue valve) or AoV plasty- Kyung-Hwan Kim

Key words: Rheumatic heart disease, Congestive heart failure, Pulmonary hypertension, Mitral valve surgery, Maze procedure, Atrial fibrillation

Influence of patient gender on mortality after aortic valve replacement for aortic stenosis

Very Long-Term Survival Implications of Heart Valve Replacement With Tissue Versus Mechanical Prostheses in Adults <60 Years of Age

Aspirin or Coumadin as the Drug of Choice

Simultaneous Aortic and Mitral Valve Replacement in Octogenarians: A Viable Option?

Incidence of Postoperative Atrial Fibrillation after minimally invasive mitral valve surgery

SURGICAL ABLATION OF ATRIAL FIBRILLATION DURING MITRAL VALVE SURGERY THE CARDIOTHORACIC SURGICAL TRIALS NETWORK

2017 Cardiovascular Symposium CARDIAC SURGERY UPDATE: SMALLER INCISIONS AND LESS COUMADIN DAVID L. SAINT, MD

Early and One-year Outcomes of Aortic Root Surgery in Marfan Syndrome Patients

Clinical material and methods. Fukui Cardiovascular Center, Fukui, Japan

The CarboMedics bileaflet prosthetic heart was introduced

Atrial fibrillation (AF) is associated with increased morbidity

Mitral Gradients and Frequency of Recurrence of Mitral Regurgitation After Ring Annuloplasty for Ischemic Mitral Regurgitation

Standarized definition of bioprosthetic valve deterioration and failure

Clinical event rates with the On-X bileaflet mechanical heart valve: A multicenter experience with follow-up to 12 years

Results of Aortic Valve Preservation and Repair

Since 1990, there has been a steady increase in cardiac

Indications and Late Results of Aortic Valve Repair

Long-Term Assessment of Mitral Valve Reconstruction With Resection of the Leaflets: Triangular and Quadrangular Resection

Long-term relative survival after primary heart valve replacement 1

How to Avoid Prosthesis-Patient Mismatch

Repair or Replacement

Spotlight on valvular heart disease guidelines. Prosthetic heart valves. Bernard Iung Bichat Hospital, Paris Diderot University Paris, France

Reconstruction of the intervalvular fibrous body during aortic and

Outcomes of Surgical Aortic Valve Replacement in Moderate Risk Patients: Implications for Determination of Equipoise in the Transcatheter Era

Subclinical leaflet thrombosis in surgical and transcatheter bioprosthetic aortic valves: an observational study

Anticoagulation Therapy and Valve Surgery. Dr Pau Kiew Kong Consultant Cardiothoracic Surgeon

The Ross Procedure: Outcomes at 20 Years

Transcription:

Durability and Outcome of Aortic Valve Replacement With Mitral Valve Repair Versus Double Valve Replacement Masaki Hamamoto, MD, Ko Bando, MD, Junjiro Kobayashi, MD, Toshihiko Satoh, MD, MPH, Yoshikado Sasako, MD, Kazuo Niwaya, MD, Osamu Tagusari, MD, Toshikatsu Yagihara, MD, and Soichiro Kitamura, MD Department of Cardiovascular Surgery, National Cardiovascular Center, Osaka, Department of Public Health, Kitasato University, Kitasato, Japan Background. The purpose of this study was to evaluate morbidity and mortality after double valve replacement (DVR) and aortic valve replacement with mitral valve repair (AVR MVP). Methods. From 1977 to 2000, 379 patients underwent DVR (n 299) or AVR MVP (n 80). Actuarial survival and freedom from reoperation were determined by the Kaplan-Meier method. Potential predictors of mortality and reoperation were entered into a Cox multiple regression model. Propensity score was introduced for the multivariable regression modeling for adjustment of a selection bias. Results. Survival 15 years after surgery was similar between the groups (DVR, 81% 3%; AVR MVP, 79% 7%; p 0.44). Freedom from thromboembolic event at 15 years was similar between the groups (p 0.25). Freedom from mitral valve reoperation at 15 years was significantly better for the DVR group (54% 5%) as For patients with aortic and mitral valve disease, double valve replacement (DVR) has been advocated as a standard surgical option, which has been safely performed even in elderly populations in recent years. In these patients, a majority of aortic valve disease required valve replacement because the early and late results of aortic valve repair have not been satisfactory [1,2]. In contrast, valve repair has been advocated in mitral valve disease [3, 4]. However, the durability and outcome of combined aortic valve replacement and mitral valve repair versus double valve replacement remain to be determined. The purpose of this study was to evaluate survival and late outcome after DVR and aortic valve replacement and mitral valve repair (AVR MVP) for double valve disease. Patients and Methods From 1977 to 2000, 379 patients underwent AVR with either mitral valve replacement (MVR) (DVR group; n Presented at the Thirty-eighth Annual Meeting of The Society of Thoracic Surgeons, Fort Lauderdale, FL, Jan 28 30, 2002. Address reprint requests to Dr Bando, Department of Cardiovascular Surgery, National Cardiovascular Center, 5-7-1 Fujishirodai, Suita, Osaka 565-8565 Japan; e-mail: kobando@hsp.ncvc.go.jp. compared with the AVR MVP group (15% 6%; p 0.0006), primarily due to progression of mitral valve pathology and early structural deterioration of bioprosthetic aortic valve used for patients with AVR MVP. After AVR MVP, freedom from mitral reoperation at 15 years was 63% 16% for nonrheumatic heart diseases, and 5% 5% for rheumatic disease (p 0.04). Conclusions. Although both DVR and AVR MVP provided excellent survival, DVR with mechanical valves should be the procedure of choice for the majority of patients because of lower incidence of valve failure and similar rate of thromboembolic complications compared with AVR MVP. MVP should not be performed in patients with rheumatic disease because of higher incidence of late failure. (Ann Thorac Surg 2003;75:28 34) 2003 by The Society of Thoracic Surgeons 299) or MVP (n 80). The cases of concomitant procedure with coronary artery bypass grafting or aortic surgery were excluded from the study. The preoperative clinical characteristics of each group are shown in Table 1. The DVR group was more common in patients with atrial fibrillation (Af) (p 0.0001). The AVR MVP group was more common in patients with pure mitral regurgitation (MR) (p 0.0001). The age of patients having bioprosthetic valve was 52 12 years old in the AVR MVP group and 50 9 years old in the DVR group. The proportion of New York Heart Association (NYHA) functional class III and IV was similar between the two groups. In the DVR group, follow-up ranged from 6 months to 20.1 years (8.6 6.1 years), with a total of 2,561 patient-years. In the AVR MVP group, follow-up ranged from 6 months to 21.7 years (9.4 7.1 years), with a total of 752 patient-years. Surgical Procedure The majority of patients with DVR had mechanical valve prostheses in both aortic (219/299 patients, 73%) and mitral (215/299, 72%) position. In contrast, a bioprosthetic valve was more frequently used in the AVR MVP group (49/80, 61%) (p 0.0001). In both groups, an Ionescu-Shiley valve (58/84 [69%] in the DVR group, 2003 by The Society of Thoracic Surgeons 0003-4975/03/$30.00 Published by Elsevier Science Inc PII S0003-4975(02)04405-3

Ann Thorac Surg HAMAMOTO ET AL 2003;75:28 34 SURGICAL OUTCOME OF AVR MVP VS DVR Table 1. Patient Characteristics DVR AVR MVP p n 299 80 Age (years; mean SD) 54.1 9.7 (27 75) 53.0 12.0 (29 78) 0.32 Female 158 (53%) 27 (34%) 0.002 NYHA class III IV 144 (48%) 35 (44%) 0.67 AF 228 (76%) 39 (49%) 0.0001 Rheumatic fever 65 (22%) 11 (14%) 0.11 CHF 103 (34%) 24 (30%) 0.71 TIA 41 (14%) 9 (1%) 0.69 MI 5 (2) 2 (0.3) 0.64 IE (medication) 6 (2%) 5 (6%) 0.06 Etiology Rheumatic 182 (61%) 43 (54%) 0.31 Degenerative 17 (5%) 20 (25%) 0.001 Endocarditis 26 (9%) 4 (5%) 0.36 Unknown 74 (25%) 13 (16%) 0.15 Mitral valve lesion Stenosis 42 (14%) 11 (13.7%) 0.67 Regurgitation 39 (13%) 44 (55%) 0.0001 Stenosis and regurgitation 218 (73%) 25 (31%) 0.0001 Follow-up periods (months) 102.8 73.3 (6 271) 112.7 84.8 (6 266) 0.30 Patient-years 2,561 752 29 CARDIOVASCULAR AF Atrial fibrillation; CHF chronic heart failure; DVR double valve replacement; NYHA New York Heart Association; TIA transient ischemic attack; MI myocardial infarction; IE infective endocarditis. 28/49 [57%] in the AVR MVP group) was primarily used as a bioprosthetic valve between 1981 and 1984 for all generations. Since then, the Carpentier Edwards valve was commonly used for the patients more than 70 years of age, and most recently, the Mosaic valve was introduced in 1999. In patients who received mechanical valves, the St. Jude Medical valve (135/215 patients, 63%) was the most frequently used in both aortic and mitral positions. The Maze procedure was more common with the DVR group as compared with the AVR MVP group because the rate of preoperative Af rhythm was more frequently associated with the DVR group as compared with the AVR MVP group (DVR, 228/299 [76%] vs AVR MVP, 39/80 [49%]; p 0.02). Several different techniques were used for MVP, including commissurotomy (36 patients, 45%), Kay procedure (33 patients, 41.3%), ring annuloplasty (10 patients, 12.5%) use of Duran or Carpentier-Edwards ring and leaflet resection (5 patients, 6.3%), or a combination of these techniques. Data Collection and Follow-Up We retrospectively reviewed the data from the operation notes, anesthesia records, clinical histories, laboratory investigations, and cardiac catheterization. This retrospective study was approved by the Internal Review Board of National Cardiovascular Center. Follow-up data were collected from National Cardiovascular Center records of outpatient visits and correspondence with referring physicians. All clinical characteristics were accumulated as a computerized database and analyzed in the Appendix. The definitions of morbidity and mortality were based on the published guidelines of Society of Thoracic Surgeons and American Association for Thoracic Surgery Guidelines for Reporting Morbidity and Mortality After Cardiac Valvular Operations [5]. Statistical Methods Statistical analysis of the two groups were performed using the Pearson chi square test with Yates correction or Fisher s exact test for categorical variables and the Mann-Whitney U test for continuous variables. Unadjusted survival curves for the two groups were generated using the Kaplan-Meier method. The log-rank test was used for the comparison of the unadjusted survival curves. Cox s multivariate regression model with the propensity score method [6] was performed to assess the influence of surgical method on the probability of survival or reoperation. The incorporation of a propensity score balances the weight of covariates between the two groups on each patient level so that the comparisons of these two groups of patients were more significant. s ratio and 95% confidence intervals (CI) were provided. All statistical analyses were performed using the software package SPSS 10.0 for Windows (SPSS Inc., Chicago, IL). Differences were considered statistically significant when p was less than 0.05. Results Early and Late Mortality Overall hospital mortality was 4.5% (17/379), which declined to 2.9% (2/69) during the last 5 years. The major

30 HAMAMOTO ET AL Ann Thorac Surg SURGICAL OUTCOME OF AVR MVP VS DVR 2003;75:28 34 Table 2. Freedom From Valve-Related Complications Complication Freedom at 15 Years (%) DVR AVR MVP p Total number 45.1 5.0 17.8 6.7 0.02 Structural valve deterioration 66.5 4.3 26.2 8.4 0.002 Nonstructural dysfunction 92.0 2.5 92.9 4.2 0.83 Valvular thrombosis 98.4 1.2 100 Thromboembolism 97.4 1.2 94.7 3.1 0.26 (neurological) Bleeding event 97.5 1.3 98.7 1.3 0.94 Prosthetic valve endocarditis 92.8 2.5 97.2 2.7 0.17 AVR aortic valve replacement; MVP mitral valve repair; DVR double valve replacement. Fig 1. Long-term actuarial survival for the subgroups of patients with AVR MVP and DVR. Solid line AVR MVP; dotted line DVR. (AVR aortic valve replacement; DVR double valve replacement; MVP mitral valve repair; Pts. patients.) causes of hospital death were postoperative low cardiac output (LOS) (5/17, 31%) or multiple organ failure (MOF) (6/17, 31%). Three deaths (0.8%) were related to the prosthetic valve failure. There were 36 late deaths, 27 in the DVR group and 9 in the AVR MVP group (p 0.70). Cardiac-related late deaths were observed in 5 patients in the DVR group, whereas only 1 patient died in the AVR MVP group. Actuarial survival at 5, 10, and 15 years was 96% 2%, 92% 4%, and 79% 7% for the AVR MVP group versus 89% 2%, 87% 2%, and 81% 3% for the DVR group, respectively (p 0.44) (Fig 1). Valve-related death occurred in 5 patients in the DVR group (5/299, 1.7%): valve thrombus (1), cerebral infarction (1), stuck valve (1), acute subdural hematoma (1), and prosthetic endocarditis (1). In contrast, there was only one valve-related death in the AVR MVP group (1/80, 1.3%): anticoagulant-related cerebral hemorrhage. Actuarial freedom from valve-related death at 5, 10, and 15 years was 100%, 98% 2%, and 98% 2% in the AVR MVP group versus 99% 1%, 99% 1%, and 97% 2% in the DVR group (p 0.73). Valve-Related Complications The actuarial estimates of freedom from overall valverelated complications at 15 years were 45% 5% and 18% 7% for the DVR group and the AVR MVP group, respectively, with significance (p 0.02) (Table 2). This was probably related to the fact that 61% of patients with AVR MVP received bioprosthetic valves, whereas only 28% of the patients with DVR had bioprosthetic valves (p 0.0001). Subsequently, structural valvular deterioration (SVD) of the bioprosthetic valve developed in 28 of 80 patients (35%) in the AVR MVP group compared with 50 of 299 (17%) patients in the DVR group (p 0.0006). Actuarial freedom from SVD at 15 years in the AVR MVP group (26% 8%) was significantly lower than that of the DVR group (67% 4%) (p 0.002). When stratified by the type of prosthesis, DVR as well as AVR MVP using bioprosthetic valve resulted in lower freedom from SVD at 15 years (27.7% 5.8% and 18.5% 7.7%, respectively) compared with both groups using mechanical valves (both 100%) (Fig 2). Anticoagulant-Related Complications The systemic anticoagulant therapy with warfarin sodium was initiated in all patients immediately after the extubation. The warfarin sodium was adjusted from 1.8 to 2.8 of INR for the MVR and from 1.5 to 2.5 for the AVR [7]. Three months later, warfarin sodium was discontinued in the patients having only bioprosthetic valve without atrial fibrillation. However, the patients who received a mechanical valve or remained in atrial fibrillation after valve surgery continued to take warfarin sodium. The Maze procedure has been done for 7 of 80 patients (9%) with AVR MVP, and 60 of 299 patients (20%) with DVR since 1994. Return to sinus rhythm was obtained for 4 of 7 patients (57%) in the AVR MVP group and 45 of 60 patients (75%) in the DVR group. Ultimately, sinus rhythm was maintained in the postoperative periods for 63% (50/80) of patients in the AVR MVP group and 33% (98/299) of patients in the DVR group, respectively. Freedom from systemic anticoagulant therapy at 10 years was 58% for the AVR MVP group and 23% for DVR group (p 0.0006). All patients with atrial fibrillation Fig 2. Freedom from structural valve deterioration for the subgroups of patients with AVR MVP and DVR stratified by the type of prosthesis. (AVR aortic valve replacement; DVR double valve replacement; MVP mitral valve repair; Pts. patients.)

Ann Thorac Surg HAMAMOTO ET AL 2003;75:28 34 SURGICAL OUTCOME OF AVR MVP VS DVR Table 3. Univariate Risk Factor Analysis for Early and Late Mortality p Value Ratio 31 Lower Upper CARDIOVASCULAR Fig 3. Freedom from mitral reoperation for the subgroups of patients with AVR MVP and DVR. (AVR aortic valve replacement; DVR double valve replacement; MVP mitral valve repair; Pts. patients.) after surgery continued to have warfarin sodium regardless of the type of valve received. Postoperative thromboembolic complication was observed in 3 of 80 (3.8%) patients with the AVR MVP group and 5 of 299 (1.7%) patients in the DVR group. All these thromboembolic events occurred in the cerebral lesion, but not in the other organs. Estimates of freedom from thromboembolism at 15 years was 95% 3% in the AVR MVP group versus 97% 1% in the DVR group (p 0.26). There was only one bleeding event (1.3%) in patients with the AVR MVP group, whereas four episodes (1.3%) occurred in the DVR group and one resulted in a fatality. Estimates of freedom from bleeding events at 15 years were 99% 1% in the AVR MVP group and 98% 1% in the DVR group (p 0.94). Reoperations Reoperation was required in 39 of 80 patients (49%) in the AVR MVP group, and 69 of 299 patients (23%) in the Fig 4. Freedom from mitral reoperation after AVR MVP stratified by the rheumatic etiology. Solid line nonrheumatic; dotted line rheumatic. (AVR aortic valve replacement; DVR double valve replacement; MVP mitral valve repair; Pts. patients.) Age (10-year increment) 0.01 1.49 1.10 2.00 Male 0.79 1.08 0.63 1.84 Atrial fiblliration 0.96 1.02 0.56 1.85 MI 0.06 3.06 0.95 9.82 TIA 0.48 0.72 0.29 1.81 CHF 0.72 1.11 0.63 1.94 RF 0.54 1.22 0.65 2.27 NYHA class IV 0.001 4.39 2.33 8.29 Year of operation 0.06 0.95 0.89 1.00 Method (AVR MVP or DVR) 0.47 0.78 0.39 1.54 Maze 0.74 0.85 0.33 2.19 CPB time 0.001 1.35 1.20 1.43 ACC time 0.02 1.52 1.06 2.17 MI myocardial infarction; TIA transient ischemic attack; CHF chronic heart failure; RF rheumatic fever; AVR aortic valve replacement; MVP mitral valve repair; DVR double valve replacement; CPB cardiopulmonary bypass; ACC aortic cross-cramp; NYHA New York Heart Association. DVR group (p 0.0001). All these patients underwent mitral valve reoperations with or without second AVR. In the AVR MVP group, the major cause of reoperation was progression of mitral stenosis or regurgitation (39/ 39) with the structural deterioration of bioprosthetic valves in the aortic position (32/39), or associated with the pannus formation after AVR with mechanical valves (2/39). Thus, the remaining 5 patients had only MVR without aortic valve surgery. In this group, reoperation was required for 22 of 28 patients (78.6%) with an Ionescu-Shiley valve 15 years after surgery, whereas 4 of 10 patients with the Carpentier-Edwards valve required reoperation during the same time period. In the DVR group, the SVD of bioprosthetic valve in either aortic or mitral position (54/69, 78%) was a primary cause of reoperation. Freedom from mitral reoperation in the AVR MVP group was significantly lower as compared with that of the DVR group (p 0.0006)(Fig 3). Although the AVR MVP group had a higher incidence of reoperation, the mortality in reoperation was similar between the two groups: 13% (5/39) in the AVR MVP group versus 9% (6/69) in the DVR group (p 0.78). Reoperation in the AVR MVP Group Stratified by Etiology of the Valve Disease In the AVR MVP group, when freedom from survival was stratified by the etiology of the valve disease, freedom from reoperation at 5, 10, and 15 years was 85% 10%, 76% 13%, and 63% 16% for nonrheumatic heart disease, and 89% 5%, 46% 11%, and 5% 5% for rheumatic heart disease, respectively (p 0.04) (Fig 4). Risk Factor Analysis for Survival By univariate analysis, significant predictors of poor survival included older age, past history of myocardial

32 HAMAMOTO ET AL Ann Thorac Surg SURGICAL OUTCOME OF AVR MVP VS DVR 2003;75:28 34 Table 4. Multivariate Risk Factor Analysis Using Propensity Score for Early and Late Death p Value Ratio Lower Upper Table 6. s in the Reoperation Model Using Propensity Score p Value Ratio Lower Upper Method (AVR MVP or DVR) 0.945 0.98 0.47 2.01 Propensity score 0.71 1.58 0.15 16.98 Age (10-year increment) 1.74 1.24 2.41 MI 0.04 3.56 1.07 11.88 NYHA class IV 0.001 4.84 2.50 9.38 Year of operation 0.89 0.83 0.95 CPB time 0.001 1.43 1.27 1.61 AVR aortic valve replacement; MVP mitral valve repair; DVR double valve replacement; MI myocardial infarction; CPB cardiopulmonary bypass; NYHA New York Heart Association. infarction, preoperative NYHA class IV, and longer cardiopulmonary bypass (CPB) time and aortic cross-clamp time (Table 3). By multivariate analysis using propensity score, significant predictors for early and late mortality included older age, past history of myocardial infarction, NYHA class IV, early year of operation, and longer CPB time (Table 4). Risk Factor Analysis for Reoperation By univariate analysis, risk for reoperation included early year of operation, mitral repair as the first operation, omission of Maze procedure for the patients with Af, and the use of bioprosthetic valve (Table 5). By multivariate analysis using propensity score, early year of operation and the use of bioprosthetic valve were predictors for reoperation (Table 6). Table 5. Results of Univariate Risk Factor Analysis for Reoperation p Value Ratio Lower Upper Age (10-year increment) 0.21 0.88 0.71 1.07 Male 0.22 0.78 0.53 1.15 Atrial fiblliration 0.56 0.89 0.59 1.34 MI 0.32 1.66 0.61 4.51 TIA 0.84 0.94 0.53 1.69 CHF 0.19 1.30 0.88 1.91 RF 0.72 0.92 0.56 1.49 NYHA class IV 0.15 0.55 0.24 1.25 Year of operation 0.001 0.85 0.81 0.90 Type of prosthesis 0.001 0.11 0.06 0.19 (mechanical) Maze 0.05 0.13 0.02 0.96 CPB time 0.44 0.89 0.66 1.20 ACC time 0.65 0.94 0.62 1.35 MI myocardial infarction; TIA transient ischemic attack; CHF chronic heart failure; RF rheumatic fever; AVR aortic valve replacement; MVP mitral valve repair; DVR double valve replacement; CPB cardiopulmonary bypass; ACC aortic cross-cramp; NYHA New York Heart Association. Method (AVR MVP or DVR) 0.06 1.50 0.98 2.29 Propensity score 0.82 0.83 0.17 4.07 Type of prosthesis (mechanical) 0.001 0.09 0.05 0.19 Year of operation 0.001 0.86 0.82 0.91 AVR aortic valve replacement; MVP mitral valve repair; DVR double valve replacement. Comment For surgery in patients with double valve disease, the choice of MVP versus MVR remains controversial. Our retrospective study of more than 22 years indicated both MVP and MVR combined with AVR provided excellent long-term survival ( 85% at 10 years after surgery in both groups). This was favorably compared with other reports [8 11], probably due to younger population (mean age, 54 years) and smaller number of patients in NYHA class III/IV (46%) in our study. Freedom from thromboembolic event was similar between the DVR and the AVR MVP group up to 15 years after surgery. Moreover, freedom from other morbidities, including major bleeding (98% 1% in the DVR group vs 99% 1% in the AVR MVP group at 15 years) or prosthetic valve endocarditis (93% 3% in the DVR group vs 97% 3% in the AVR MVP group at 15 years) was also similar between the groups. These results indicated that both DVR and AVR MVP provided excellent survival and low morbidity up to 15 years after surgery In sharp contrast, regarding reoperation, a significantly higher incidence was observed in the AVR MVP group as compared with the DVR group. This was probably related to the fact that two-thirds of patients with AVR MVP received bioprosthetic valves even in younger populations; of those, 57% had the first-generation Ionescu- Shiley valve [12]. Early structural deterioration of this valve was the primary cause of reoperation for the AVR MVP group. On the other hand, double valve surgery using mechanical valve in both groups provided better results without structural deterioration, which resulted in no reoperation (Fig 2). In the AVR MVP group, the patients with rheumatic heart disease had higher risk for reoperation as compared with those with nonrheumatic heart disease. Because the majority of patients with rheumatic heart disease had some component of mitral stenosis, decision to perform the MVP versus MVR is difficult [13]. In this series, open mitral commissurotomy was commonly performed for the patients with mitral stenosis; most of these patients eventually required mitral valve replacement. Thus, our results indicated that double valve replacement might be a best option for patients with rheumatic heart disease [14]. For risk factor analysis of mortality and freedom from reoperation, we have used a multivariable model with the incorporation of propensity score. This will minimize

Ann Thorac Surg HAMAMOTO ET AL 2003;75:28 34 SURGICAL OUTCOME OF AVR MVP VS DVR the biases in the observational study and have demonstrated that the choice of MVR or MVP does not significantly affect patient long-term survival up to 20 years (Table 5). Instead, history of myocardial infarction and preoperative NYHA class IV were the strong predictors for early and late death after surgery for double valve disease. Moreover, multivariable risk analysis using propensity score revealed that only bioprosthesis and early year of operation were the significant predictors for reoperation. There was certainly a logistic concern that year of operation was a risk simply because cases in recent years did not have enough follow-up time. However, if we analyze the data in patients before 1995, year of operation was still the strong predictor for reoperation (data not shown). Advanced myocardial protection and improved operative technique as well as well understanding of pathophysiology of the valves may contribute to these improvements. The major limitation of our study is that it was not randomized, and there were significant differences between the baseline characteristics of patients in the DVR group and the AVR MVP group. The decision for MVP versus MVR reflected the surgeons experience. To minimize the effect of these biases, propensity score was incorporated into the multivariate analysis. Another limitation includes inability to assess precise valve function by echocardiography because late follow-up echocardiography was available in only 60% of the patients, and this was not incorporated in the current study. Instead, assessment of durability of valves was based on either survival or free from reoperation. Further prospective study is certainly warranted to elucidate the precise difference of durability of valves in the two cohorts. In conclusion, although both DVR and AVR MVP resulted in good survival, DVR with mechanical valves should be the procedure of choice for the majority of patients, because of higher freedom from valve failure and similar rate of thromboembolic complications as compared with AVR MVP. MVP should not be performed in patients with rheumatic disease because of the high incidence of late failures. References 1. Gillinov AM, Blackstone EH, Cosgrove DM, et al. Durability of combined aortic and mitral valve repair. Ann Thorac Surg 2001;72:20 7. 2. Casselman FP, Gillinov AM, Akhrass R, Kasirajan V, Blackstone EH, Cosgrove DM. Intermediate term durability of bicuspid aortic valve repair for prolapsing leaflet. Eur J Cardiothorac Surg 1999;15:302 8. 3. Fasol R, Mahdjoobian K, Joubert-Hubner E. Mitral repair in patients with severely calcified annulus: feasibility, surgery and results. J Heart Valve Dis 2002;11:153 9. 4. Gillinov AM, Cosgrove DM. Mitral valve repair for degenerative disease. J Heart Valve Dis 2002;11(Suppl 1):S15 20. 5. Edmunds LH Jr, Grunkemeier GL, Miller DC, Weisel RD. Guidelines for reporting morbidity and mortality after cardiac valvular operaions. Ann Thorac Surg 1996;62:932 5. 6. Rosenbaum PR, Robin DB. The central role of the propensity score in observational studies for causal effects. Biometrika 1983;70:41 55. 7. Matsuyama K, Matsumoto M, Sugita T, et al. Anticoagulant threrapy in Japanese patients with mechanical mitral valve. Circ J 2002;66:668 70. 8. Brown PS Jr, Roberts CS, Mcintosh CL, Swain JA, Clark RE. Relation between choice of prostheses and late outcome in double valve replacement. Ann Thorac Surg 1993;55:631 40. 9. Milano A, Guglielmi C, De Carlo M, et al. Valve-related complications in elderly patients with biological, and mechanical aortic valves. Ann Thorac Surg 1998;66(Suppl): S82 7. 10. Armenti F, Stephenson LW, Edmunds LH Jr. Simultaneous implantation of St. Jude Medical aortic and mitral prostheses. J Thorac Cardiovasc Surg 1987;94:733 9. 11. Mueller XM, Tevaearai HT, Stumpe F, et al. Long-term results of mitral-aortic valve operations. J Thorac Cardiovasc Surg 1998;115:298 309. 12. Machida H, Ueda H, Nakano K, et al. A morphologic study of Carpentier-Edwards pericardial xenografts in the mitral position exhibiting primary tissue failure in adults in comparison with Ionescu-Shiley pericardial xenografts. J Thorac Cardiovasc Surg 2001;122:649 55. 13. Duran CM, Gometza B, De Vol EB. Valve repair in rheumatic mitral disease. Circulation 1991;84(Suppl 5):III125 32. 14. Skudicky D, Essop MR, Sareli P. Time-related changes in left ventricular function after double valve replacement for combined aortic and mitral regurgitation in a young rheumatic population. Circulation 1997;95:899 904. Appendix s Studied in Multivariable Analysis of Risk Factors for Survival and Reoperation* Demography Age (years) at operation, gender Cardiac Comorbidity NYHA functional class, history of myocardial infarction, transient ischemic attack, chronic heart failure, rheumatic fever, preoperative atrial fibrillation Operative Procedures and Time Year of operation, surgical method of AVR with MVP, or double valve replacement, concomitant Maze procedure, cardiopulmonary bypass time, and aortic cross-clamp time. *All variables are dichotomous (yes/no), unless indicated to be continuous or ordinal. 33 CARDIOVASCULAR DISCUSSION DR LISHAN AKLOG (Boston, MA): That was an excellent presentation. I just had a question; maybe I missed it, but I did not see where you specified what the severity of mitral regurgitation was in these patients preoperatively and, more specifically, what the functional classification was. And related to that, what was the technique of mitral repair? Did everybody just receive an annuloplasty alone or were there other concomitant techniques that were used in the mitral repair patients?

34 HAMAMOTO ET AL Ann Thorac Surg SURGICAL OUTCOME OF AVR MVP VS DVR 2003;75:28 34 DR HAMAMOTO: Preoperatively echocardiography was performed and severity of mitral valve dysfunction was almost the same between the AVR plus MVP group and double valve replacement group. In the case of aortic valve replacement, it was mechanical valve plus mitral valve repair group; the severity of mitral valve dysfunction was a little bit milder than the aortic valve replacement with bioprosthetic mitral valve repair. DR AKLOG: How severe was it? Did these patients have moderate MR, was it mild MR, and what was the severity, on average, even if it was the same between the two groups? DR HAMAMOTO: In the AVR MVP group, the severity of mitral valve dysfunction was moderate to severe. Similar results were found with the DVR group; especially in the AVR with mechanical valve plus mitral valve plasty group, they had mild to moderate regurgitation. DR BANDO: Dr Aklog, let me answer the question for you. I am a co-author of this paper. The patients with rheumatic heart disease and significant mitral stenosis were the majority of patients. That is why we used commissurotomy in the patients. But for the majority of the patients with pure mitral regurgitation, we do use the ring as well as the posterior leaflet repair. DR BELHAM AKPINAR (Istanbul, Turkey): As far as I understood, you stopped giving anticoagulation after some time in both groups, more commonly in the group that you had repair of the mitral valve. Is that true, you do not give any anticoagulation after some time? You stop giving anticoagulation? DR HAMAMOTO: In both groups just after the operation anticoagulation was started by warfarin, but after 3 months the bioprosthetic valve replacement plus mitral valve plasty group had no anticoagulation, no antiplatelet drugs. DR AKLOG: What was the technique of repair? Was it annuloplasty alone? DR HAMAMOTO: The technique of mitral valve repair is commissurotomy in 40%, Kay procedure was in about 40%, and annuloplasty about 20%, and these techniques were combined, two or three techniques were combined. DR AKLOG: Were you able to correlate the durability with the specific technique? You said only 20% got an annuloplasty ring. Was there a correlation between the technique of repair? The ones that failed, were they less likely to have had an annuloplasty ring? DR JONATHAN HAMMOND (Hartford, CT): In the mitral valve repair group that was reoperated upon, maybe you said this in your presentation, but I did not catch it, which valve or valves were being redone? DR HAMAMOTO: Aortic valve replacement with the mitral valve repair group had a higher incidence of reoperation. DR HAMMOND: In other words, the mitral repair was durable. It was the aortic valve that had to be redone? DR HAMAMOTO: In almost all cases the repair of the mitral valve is replacement with bioprosthetic mitral valve repair.