AC40 Technical Specificatons. Technical Specifications AC40. Clinical Audiometer D F 2017/11

Similar documents
AC40 Technical Specificatons Page 1. Technical Specifications AC40. Clinical Audiometer

Diagnostic Audiometer

AD226 Diagnostic Audiometer

The true clinical hybrid audiometer Stand alone & PC-based audiometry in one box. Interacoustics. Clinical Audiometer AC40.

The true clinical hybrid audiometer. Interacoustics. Clinical Audiometer AC40. Stand alone & PC-based audiometry in one box.

The true hybrid Stand alone & PC-based audiometry in one box

The true hybrid Stand alone & PC-based audiometry in one box

Equinox 2.0. PC-based audiometer. Time saving solutions. Interacoustics. leading diagnostic solutions

TWO CHANNEL CLINICAL AUDIOMETER AUDIOSTAR PRO

The true hybrid Stand alone & PC-based audiometry in one box

AC40. Clinical Audiometer. Save time Focus on results. Interacoustics. l e a d i n g d i a g n o s t i c s o l u t i o n s

GSI AUDIOSTAR PRO CLINICAL TWO-CHANNEL AUDIOMETER

Oscilla - excellence since 1960

AUDIOLAB Two channel clinical audiometer. Tonal Audiometry Vocal Audiometry MASKING SISI ABLB Decay Test BEKESY

AUDIOMETERS AUDIXI 10

AA222 / AA220. Audio Traveller. Save time on routine. Focus on results. Interacoustics. leading diagnostic solutions

AA-M1C1. Audiometer. Space saving is achieved with a width of about 350 mm. Audiogram can be printed by built-in printer

Diagnostic Impedance & Audiometry in one solution

UNITY 2. a state-of-the-art audiological integrated diagnostic and fitting system

AT235 Middle Ear Analyzer. Diagnostic & clinical tympanometry with basic audiometry

What s New in Primus

Audiology Equipment p r o d u c t s c AtA l o g u E

General about Calibration and Service on Audiometers and Impedance Instruments

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard

AC40. The true clinical. hybrid

FONIX FA-12 Hearing Evaluator Digital Audiometer

OIML R 122 Annex C RECOMMENDATION. Edition 1999 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

Operating Instructions MA 52

AMBCO AUDIOMETER

Additional Information. PC-based Audiometer Equinox 2

MA 25 Operating Manual

The professional fitting solution

AMBCO 1000+P AUDIOMETER

MA 40 Operating Instructions

Contents. QuickSIN.. 15 Hearing Loss Simulator Master Hearing Aid Printing Limited Warranty.. 20 #0086.

Operating Instructions MA 25

Affinity 2.0 / Equinox 2.0 Hearing Aid Analyzer

Equinox 2.0 PC-based audiometer. Not just an audiometer - A full counseling and reporting solution

Reliable, flexible & precise

Operation Manual. Screening Audiometer AS608/AS608e

myaudiometer. It s familiar, and it s so much

INTRODUCTION TO PURE (AUDIOMETER & TESTING ENVIRONMENT) TONE AUDIOMETERY. By Mrs. Wedad Alhudaib with many thanks to Mrs.

AD629 The true hybrid

Operation Manual MA 41

This Page Left Intentionally Blank

Operating Instructions MA 41

Additional Information Callisto Portable Audiometry REM & HIT

This Page Intentionally Left Blank

Neuro-Audio Version 2010

General Catalogue. Product Line for Hearing Screening & Diagnostics

TRAINING MANUAL. AVANT The Perfect Screening Audiometer AIR+

MADSEN Itera II. User Guide. Doc. No EN/04 Part No EN

AT235/AT235h Middle Ear Analyzers. Diagnostic & clinical tympanometry with basic audiometry.

EPIC-PLUS System for auditory evoked potentials and neuro-otology. PEA - VEMPs ASSR - E-ABR FACIAL NERVE

Good Things Come In Small Packages. Diagnostic & Hearing Instrument Fitting Technologies CATALOG

Affinity 2.0 integrated fitting solution. Audiometry, REM, HIT, and Visible Speech Mapping

TRAINING MANUAL. AVANT Air, Bone, Speech and Masking Audiometry AUDIOMETERS.

General Catalogue. Product Line for Hearing Screening & Diagnostics

Organisation Internationale de Métrologie Légale

ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE VEMP ECochG MLR P300

The integrated fitting solution

Quick Guide Binaural REM

SOFTWARE INSTRUCTION MANUAL

User Manual. - Pro Edition -

MA 39 Operating Instructions

Instructions for Use - US Diagnostic Suite 2.4.0

AURICAL Aud. User Guide. Doc. No EN/07 Part No EN

TRAINING MANUAL. MedRx TINNOMETER. Revolutionary Tinnitus Assessment.

MADSEN Xeta. Reference Manual. Doc. No EN/16 Part No EN

TRAINING MANUAL AVANT ARC. Audiometry & Binaural REM/LSM in One System.

General Catalogue. Hearing Screening & Diagnostics

ECHOLAB. Screening and Clinical Modality. User Programmable Protocols. Otoacoustic Emissions System TEOAE - DPOAE - ABR - AABR

Precision Audiometric Instruments

User Manual. - Pro Edition -

Precision Audiometric Instruments

GSI 61 CLINICAL TWO-CHANNEL AUDIOMETER

General Catalogue. Hearing Screening & Diagnostics

A full product range for your every need. World leading diagnostic solutions

FONIX FP35. Ease and Accuracy with the FP35 Touch Hearing Aid Analyzer! Visible Speech

Price list Tools for Research & Development

Supplementary Online Content

General Catalogue. Product Line for Hearing Screening & Diagnostics

INSTALLATION MANUAL. AVANT Air, Bone, Speech and Masking Audiometry AUDIOMETERS.

Amplivox Ltd Model 240 Diagnostic Audiometer Operating Manual

Amplivox Ltd Model 116 Screening Audiometer Operating Manual

COPYRIGHT Danish Standards. NOT FOR COMMERCIAL USE OR REPRODUCTION. DS/EN ISO :1998

A FRESH Approach to Pediatric Behavioral Testing

ER75 Electro-Acoustic Ear Simulator. Operating Manual

Operation Manual MA 27 / MA 27e

User Guide. For Jacoti Hearing Center Pro Version 1.0. Manufacture Year 2017

User groups Most sensorineural, conductive and mixed hearing losses in the categories of severe and profound.

GRASON-STADLER HEARING ASSESSMENT SYSTEMS

PICCOLO PORTABLE AUDIOMETER USER MANUAL

CA850 Series 5 Audiometer Operating Manual 3 January, CA850 Series 5. Automatic Audiometer Operating Manual

MedRx HLS Plus. An Instructional Guide to operating the Hearing Loss Simulator and Master Hearing Aid. Hearing Loss Simulator

Transcription:

AC40 Technical Specificatons Page 1 Technical Specifications AC40 Clinical Audiometer D-0106990-F 2017/11

AC40 Technical Specificatons Page 2 License Overview International configuration AC40 Basic license Etended license Licenses Audiometry Basic Audiometry Békésy SISI Langenbeck Stenger Modified Hughson-Westlake ABLB Speech testing with CD/Mic Weber Build-in wave files Binaural Speech Hearing Loss Simulator (HLS) Tone Decay Pediatric Noise MLD Multi Frequency (MF) Freefield Power (4 20W) Sync mode - Audiogram transfer optional optional MHA QuickSIN optional optional TEN test optional High Frequency (HF) Freefield Lineout Hyrbid mode - PC controlled mode optional optional Sync mode - Audiogram transfer optional optional Fuctions available only in Diagnostics suite MaskingHelper

AC40 Technical Specificatons Page 3 Languages supported in IMP and AUD Chinese Czech English Finnish French German Greek Italian Japanese Korean Norwegian Polish Portuguese Russian Spanish Turkish IMP MT10 X X X Eisting AT235 X X New AT235 X X X X X X X X X X X X X X X X Eisting AA222 X X New AA222 X X X X X X X X X X X X X X X X Titan X X X X X X X X X X X AUD AS608 X X X X AD226 X X X X X X X X X X AD629 / AD229 X * X * X X * X X X * X X* X * X * X X * X * X X AC40 X * X * X X * X X X * X X* X * X * X X * X * X X Suites Titan suite X X X X X X X X X X X X DS X X X X X X X X X X X X X X

AC40 Technical Specificatons Page 4 Included and Optional Parts Included Parts AC40 Goose neck 1059 microphone DD45 Audiometric headset B81 bone conductor headset 2 APS3 Patient response switch HDA300 Phone headset for HF Cleaning cloth Power cable Instructions for Use AC40 Monitor Headset with boom Optional Parts TDH39AA with Amplivo Headset DD450 Audiometric headset DD45 with Peltor Headset B71 bone conductor headset Eartone 5A 10 Ohm Eartone 3A 10 Ohm IP30 insert phone 10 Ohm CIR33 insert earphone kit for masking or monitoring Amplivo audiocups, noise reducing headset Talk back microphone Sound field speakers SP90 (with eternal power amp) AP12 Power Amplifier 212 Watt AP70 Power Amplifier 270 Watt Cable USB 2m Diagnostic Suite OtoAccess database

AC40 Technical Specificatons Page 5 General Technical Specifications AC40 Technical Specification Safety Standards IEC60601-1:2005; ES60601-1:2005/A2:2010; CAN/CSA-C22.2 No. 60601-1:2008; IEC60601-1:1988+A1+A2 Class I Type B Applied parts IP0 EMC Standard IEC 60601-1-2:2007 Audiometer Standards Tone: IEC 60645-1:2012/ANSI S3.6:2010 Type 1- Speech: IEC 60645-2:1993/ANSI S3.6:2010 Type A or A-E Calibration Calibration information and instructions is located in the AC40 Service manual Air TDH39: ISO 389-1 1998, ANSI S3.6-2010 Conduction DD45: PTB/DTU report 2009 HDA300: PTB report PTB 1.61 4064893/13 HDA280 PTB report 2004 E.A.R Tone 3A/5A: ISO 389-2 1994, ANSI S3.6-2010 CIR 33 ISO 389-2 1994 IP30 ISO 389-2 1994, ANSI S3.6-2010 DES- 2361 Bone B71: ISO 389-3 1994, ANSI S3.6-2010 Conduction B81 ISO 389-3 1994, ANSI S3.6-2010 Placement: Mastoid Free Field ISO 389-7 2005, ANSI S3.6-2010 High ISO 389-5 2006, ANSI S3.6-2010 Frequency Effective ISO 389-4 1994, ANSI S3.6-2010 masking Transducers TDH39 Headband Static Force 4.5N ±0.5N DD45 Headband Static Force 4.5N ±0.5N HDA300 Headband Static Force 8.85N ±0.5N HDA280 Headband Static Force 5N ±0.5N DD450 Headband Static Force 10N ±0.5N B71 Bone Headband Static Force 5.4N ±0.5N B81 Bone Headband Static Forces 5.4N±0.5N E.A.R Tone 3A/5A CIR 33 IP30 Patient Response switch Two push button. Patient communication Talk Forward (TF) and Talk Back (TB). Monitor Real stereo output through built-in speakers or through eternal earphone or assistant monitor.

AC40 Technical Specificatons Page 6 Special tests/test battery (some are optional) Stimuli Tone Warble Tone Pediatric Noise Wave file Masking Presentation Intensity Frequency range Speech Stenger ABLB Weber Tone decay Langenbeck (tone in noise). Masking Level Difference Pediatric Noise Stimuli Multi Frequency High Frequency Speech from Hard-drive (Wave Files) SISI Master Hearing Aid Hearing Loss Simulator QuickSIN(tm) Auto threshold: o Hughson Westlake o Békésy 125-20000Hz separated in two ranges 125-8000Hz and 8000-20000Hz. Resolution 1/2-1/24 octave. 1-10 Hz sine +/- 5% modulation A special narrowband noise stimulus. The bandwidth is frequency depended 125-250 Hz 29%, 500Hz 24%, 750 Hz 20%, 1kHz 17%, 1.5kHz 13%, 2kHz 11%, 3kHz 9% from 4kHz and up is fi 8%, 44100Hz sampling, 16 bits, 2 channels Automatic selection of narrow band noise (or white noise) for tone presentation and speech noise for speech presentation. Narrow band noise: IEC 60645-1 2012, 5/12 Octave filter with the same centre frequency resolution as pure Tone. White noise: 80-20000Hz measured with constant bandwidth Speech Noise. IEC 60645-2:1993 125-6000Hz falling 12dB/octave above 1KHz +/-5dB Manual or Reverse. Single or multiple pulses. Check the accompanying Appendi Available Intensity Steps is 1, 2 or 5dB Etended range function: If not activated, the Air Conduction output will be limited to 20 db below maimum output. 125Hz to 8kHz (Optional High Frequency: 8 khz to 20 khz) 125Hz, 250Hz, 750Hz, 1500Hz and 8kHz may freely be deselected Frequency Response: (Typical) Frequency Linear [db] FFequv [db] [Hz] Et. Int. Et. Int. sign 1 sign 2 sign 1 sign 2 TDH39 125-250 +0/-2 +0/-2 +0/-8 +0/-8 (IEC 60318-3 250-4000 +2/-2 +2/-1 +2/-2 +2/-2 4000-6300 +1/-0 +1/-0 +1/-0 +1/-0 DD45 (IEC 60318-3 E.A.R Tone 3A (IEC 60318-5 125-250 +0/-2 +1/-0 +0/-8 +0/-7 250-4000 +1/-1 +1/-1 +2/-2 +2/-3 4000-6300 +0/-2 +0/-2 +1/-1 +1/-1 250-4000 +2/-3 +4/-1 (Non linear)

AC40 Technical Specificatons Page 7 Eternal signal Free Field output (nonpowered) Internal storage IP 30 250-4000 +2/-3 (Non linear) (IEC 60318-5 +4/-1 250-4000 +12/-12 (Non linear) B71 Bone Conductor (IEC 60318-6 +12/-12 2% THD at 1000 Hz ma output +9 db (increasing at lower frequency) Level range: -10 to 60 db HL 1. Et. sign: CD input 2. Int. sign: Wave files Speech replaying equipment connected to the CD inputs must have a signal-to-noise ratio of 45 db or higher. The speech material used must include a calibration signal suitable for adjusting the input to 0 dbvu. Power amplifier and loudspeakers With an input of 7 Vrms - Amplifier and loudspeakers must be able to create a Sound Pressure Level of 100 db in a distance of 1 meter - and meet the following requirements: Frequency Response 125-250 Hz +0/-10 db 250-4000 Hz ±3 db 4000-6300 Hz ±5 db Total Harmonic Distortion 80 db SPL < 3% 100 db SPL < 10% 1000 clients and 50.000 sessions/measurements/audiograms (may depend on session type/size) Signal Indicator(VU) Time weighting: 300mS Dynamic range: 23dB Rectifier characteristics: RMS Selectable inputs are provide with an attenuator by which the level can be adjusted to the indicator reference position(0db) Data Connections (sockets) for connection of accessories 4 USB A 1 USB B for PC connection (compatible with USB 1.1 and later) 1 LAN Ethernet (not used) Eternal devices (USB) Standard PC mouse and keyboard (for data entry) Supported printers: Please contact local distributer for a list of approved PC printers. Display 8.4 inch high resolution color display 800600. HDMI output Provides a copy of the built-in screen in HDMI format 800600 resolution Input Specifications TB 212 uvrms at ma. gain for 0dB reading Input impedance : 3.2KOhm Mic.2 212 uvrms at ma. gain for 0dB reading Input impedance : 3.2KOhm CD1/2 16mVrms at ma. gain for 0dB reading Input impedance : 47KOhm TF (side panel) 212uVrms at ma. gain for 0dB reading Input impedance : 3.2KOhm TF (front panel) 212uVrms at ma. gain for 0dB reading Input impedance : 3.2KOhm Wave files Plays wave file from internal SD card Output Specifications FF 1/2/3/4 Line output 7Vrms at 2KOhms load FF 1 / 2 / 3 / 4 - powered 420W (only 220W can be used by software at the moment) Left & Right 7Vrms at 10 Ohms load Ins. Left & Right 7Vrms at 10 Ohms load HF Left & Right 7Vrms at 10 Ohms load HLS 7Vrms at 10 Ohms load

AC40 Technical Specificatons Page 8 Bone 1+2 7Vrms at 10 Ohms load Ins. Mask 7Vrms at 10 Ohms load Monitor headset (side panel) 2 3Vrms at 32 Ohms / 1.5Vrms at 8 Ohms load Assist Mon. Ma.3.5Vrms. by 8 Ω load 70Hz-20kHz ±3dB Display 8.4 inch high resolution colour display 800600 piels Compatible software Diagnostic Suite - Noah, OtoAccess and XML compatible Dimensions (LWH) 522 366 98 cm / 20.6 14.4 3.9 inch Hight with display open: 234 mm / 9.2 inch Weight 7.9kg / 17.4lb Power supply 100V~/0.8A 240V~/0.4A 50-60Hz Rated at: 2FF, 1kHz pure-tone, NBN 1kHz Operation environment Temperature: 15-35 C Re. Humidity: 30-90% Non condensing Ambient pressure: 98-104 kpa Transport and storage Transport temperature: -20-50 C Storage temperature: 0-50 C Re. Humidity: 10-95% Non condensing Warm up time Appro. 1 minute