Interactive Simulator for Evaluating the Detection Algorithms of Implantable Defibrillators

Similar documents
Clinical Results with the Dual-Chamber Cardioverter Defibrillator Phylax AV - Efficacy of the SMART I Discrimination Algorithm

Diagnostic Value of Single Versus Dual Chamber Electrograms Recorded from an Implantable Defibrillator

ICD Discrimination Algorithms

Dual-Chamber Implantable Cardioverter-Defibrillator

A New Dual Chamber Cardioverter-Defibrillator with Left Atrial Pacing Support

EHRA Accreditation Exam - Sample MCQs Cardiac Pacing and ICDs

Repetitive narrow QRS tachycardia in a 61-year-old female patient with recent palpitations

Tachyarrhythmia Suspicion and Detection

SVT Discriminators. Definition of SVT Discrimination. Identify which patient populations might benefit from these features

Automatic Identification of Implantable Cardioverter-Defibrillator Lead Problems Using Intracardiac Electrograms

PARAD/PARAD+ : P and R Based Arrhythmia Detection

Critical Analysis of Dual-Chamber Implantable Cardioverter-Defibrillator Arrhythmia Detection

Modern Trends and Clinical Experience with Dual-Chamber ICDs: Analysis of 473 Phylax AV Implants

Wide QRS Tachycardia in a Dual Chamber Pacemaker Patient: What is the Mechanism?

INTERPRETING THE ECG IN PATIENTS WITH PACEMAKERS

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE

PERMANENT PACEMAKERS AND IMPLANTABLE DEFIBRILLATORS Considerations for intensivists

EHRA Accreditation Exam - Sample MCQs Invasive cardiac electrophysiology

Diagnostic capabilities of the implantable therapeutic systems

Teaching Rounds in Cardiac Electrophysiology

Programming of Bradycardic Parameters. C. W. Israel, M.D. Dept. of Cardiology Evangelical Hospital Bielefeld Germany

Clinical Cardiac Electrophysiology

Inappropriate electrical shocks: Tackling the beast

John H. Ip, M.D FACC Associate Professor of Medicine Michigan State University Medical Director, EP Service

ICD: Basics, Programming and Trouble-shooting

Advanced ICD Concepts

Bernard Belhassen, MD; Roman Fish, MD; Sami Viskin, MD; Aharon Glick, MD; Michael Glikson, MD; Michael Eldar, MD

NEIL CISPER TECHNICAL FIELD ENGINEER ICD/CRTD BASICS

Emergency Medical Training Services Emergency Medical Technician Paramedic Program Outlines Outline Topic: WPW Revised: 11/2013

Clinical and Electrocardiographic Characteristics of Patients with Brugada Syndrome: Report of Five Cases of Documented Ventricular Fibrillation

The Nuts and Bolts of ICD Therapy

MEDTRONIC CARELINK NETWORK FOR PACEMAKERS. Comparison between the Medtronic CareLink Network for Pacemakers and Transtelephonic Monitoring

Biatrial Stimulation and the Prevention of Atrial Fibrillation

Atrioventricular (AV) Nodal Reentry Associated with 2:1 Infra-His Conduction Block during Tachycardia in a Patient with AV Nodal Triple Pathways

A Prospective Study Comparing the Sensed R Wave in Bipolar and Extended Bipolar Configurations: The PropR Study

-RHYTHM PRACTICE- By Dr.moanes Msc.cardiology Assistant Lecturer of Cardiology Al Azhar University. OBHG Education Subcommittee

December D. EL ALLAF Centre Hospitalier Hutois, Huy, Belgium. P. ATTUEL Centre Chirurgical Val d'or, Saint Cloud, France

Rate: The atrial and ventricular rates are equal; heart rate is greater than 100 bpm (usually between bpm).

National Coverage Determination (NCD) for Cardiac Pacemakers (20.8)

Case Report Simultaneous Accessory Pathway and AV Node Mechanical Block

PATIENT WITH ARRHYTHMIA IN DENTIST S OFFICE. Małgorzata Kurpesa, MD., PhD. Chair&Department of Cardiology

Cardiac rhythm detailed monitoring by an implanted pacemaker: The iecg solution

EKG Abnormalities. Adapted from:

Tech Corner. ATP in the Fast VT zone

A Closer Look Product Education at a glance

Arrhythmia Management Joshua M. Cooper, MD, FHRS, FACC

A Narrow QRS Complex Tachycardia With An Apparently Concentric Retrograde Atrial Activation Sequence

Introduction to a new "X out of Y" Mode-Switching Algorithm in Inos² CLS and Logos Dual-Chamber Pacemakers

Basic Electrophysiology Protocols

A 'shocking' case rectified

CLINICAL CARDIAC ELECTROPHYSIOLOGY Maintenance of Certification (MOC) Examination Blueprint

Chapter 16: Arrhythmias and Conduction Disturbances

Journal of Arrhythmia

2017 BDKA Review. Regularity Rate P waves PRI QRS Interpretation. Regularity Rate P waves PRI QRS Interpretation 1/1/2017

Subcutaneous implantable cardioverter defibrillator insertion for preventing sudden cardiac death

Recurrent Implantable Defibrillator Discharges (ICD) Discharges ICD Storm

Document Version Publisher s PDF, also known as Version of Record (includes final page, issue and volume numbers)

Advanced ICD Troubleshooting: Part I REVIEW

UNDERSTANDING ELECTROPHYSIOLOGY STUDIES

Supplemental Material

Julie A. Thompson, MSE, and Janice M. Jenkins, PhD

Pacing and Device Jargon Made Simple. Dr Jonathan Timperley MB ChB MD FRCP Consultant Cardiologist Northampton General Hospital

The Therapeutic Role of the Implantable Cardioverter Defibrillator in Arrhythmogenic Right Ventricular Dysplasia

Differentiating Junctional Tachycardia and Atrioventricular Node Re-Entry Tachycardia Based on Response to Atrial Extrastimulus Pacing

Intermittent episodes of paced tachycardia: what is the cause?

Cardiac Implanted Electronic Devices Pacemakers, Defibrillators, Cardiac Resynchronization Devices, Loop Recorders, etc.

CARDIOINSIGHT TM NONINVASIVE 3D MAPPING SYSTEM CLINICAL EVIDENCE SUMMARY

Shock Reduction Strategies Michael Geist E. Wolfson MC

Successful treatment of tachycardia-induced cardiomyopathy secondary to dual atrioventricular nodal nonreentrant tachycardia using cryoablation

Project Title Temporary Pacemaker Training Simulator

EPS Case presentation Looks like VT but it isn t!

Electrocardiography for Healthcare Professionals

In certain cases of supraventricular

8/20/2012. Learning Outcomes (Cont d)

CURRICULUM GOALS AND OBJECTIVES CLINICAL CARDIOVASCULAR ELECTROPHYSIOLOGY TRAINING PROGRAM. University of Florida Gainesville, Florida

Dual chamber pacing mode in an atrial antitachycardia pacing device without a ventricular lead e A necessary evil

Friedman, Rott, Wokhlu, Asirvatham, Hayes 201. Figure 65.7 Shortening of the AV interval during pacing.

AF monitoring and stroke: XPECT & REVEAL LINQ. Helmut Pürerfellner, Linz, Austria

Permanent Pacemaker Implantation Post Cardiac Surgery: A Cautionary Tale

Long Term Monitoring of the Intrinsic Ventricular Monophasic Action Potential with an Implantable DDD Pacemaker

Introduction. CLINICAL RESEARCH Clinical Trial Design. Mohammad Saeed 1 *, Mehdi Razavi 1, Curtis G. Neason 2, and Simona Petrutiu 2. Aims.

Dr.Binoy Skaria 13/07/15

Basic Dysrhythmia Interpretation

Practice Questions.

TACHYARRHYTHMIAs. Pawel Balsam, MD, PhD

Step by step approach to EKG rhythm interpretation:

Detection of Atrial Fibrillation and Flutter by a Dual-Chamber Implantable Cardioverter-Defibrillator

Introduction. * Corresponding author. Tel: þ address:

I have no conflicts of interest relative to this lecture.

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE GUIDANCE EXECUTIVE (GE)

a lecture series by SWESEMJR

COMPLEX CASE STUDY INNOVATIVE COLLECTIONS. Case presentation

WPW syndrome and AVRT

Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing. D. J. McMahon cewood rev

BHRS Prep course Pub style Quiz NOT A

GE Healthcare. The GE EK-Pro Arrhythmia Detection Algorithm for Patient Monitoring

file://c:\documents and Settings\admin\My Documents\CV\92.htm

Inappropriate ICD Discharge Related to Electrical Muscle Stimulation in Chiropractic Therapy: A Case Report

Implantable Cardioverter-Defibril. Defibrillators. Ratko Magjarević

PERIOPERATIVE MANAGEMENT: CARDIAC PACEMAKERS AND DEFIBRILLATORS

Transcription:

22 March 2002 Interactive Simulator for Evaluating the Detection Algorithms of Implantable Defibrillators F. HINTRINGER, O. PACHINGER Division of Cardiology, Department for Internal Medicine, University of Innsbruck School of Medicine, Innsbruck, Austria Summary Despite sophisticated implantable cardioverter-defibrillator (ICD) detection algorithms, inappropriate therapy for supraventricular tachyarrhythmias is still a common problem. A comparison of detection algorithms based on the specificity to detect supraventricular tachyarrhythmias reported from different clinical studies is of a limited value because the spectrum of tachyarrhythmias recorded during these studies may vary substantially. In addition, the values of specificity derived from simulations performed by each manufacturer separately do not allow a correct comparison of the performance of different detection algorithms unless the database of tachyarrhythmias is uniform for all devices compared. Based on tachyarrhythmias recorded during electrophysiological study, we created a database including supraventricular and ventricular tachyarrhythmias that may serve as such a uniform database for direct comparison of all available ICD detection algorithms. By customizing a simulator, we created a fully interactive device compatible with all ICDs via standard connectors that may serve as a uniform platform to evaluate and compare ICD detection algorithms. In addition, it is a valuable tool for selecting the optimum ICD for a patient with a specific spectrum of arrhythmias and training physicians. Key Words Tachyarrhythmia, specificity of detection algorithms, implantable cardioverter-defibrillator (ICD) Introduction Clinical data comparing the specificity for detection of supraventricular tachyarrhythmias by different dualchamber implantable cardioverter-defibrillator (ICD) algorithms are scarce, and only preliminary data are currently available. These data include pre-market release studies, reports on the first clinical experience with a new device, or comparison of a single-chamber algorithm with that of a dual-chamber [1-6]. A comparison of algorithms based on the specificity derived from different clinical studies and reported by the manufacturers is of limited value because the spectrum of tachy-arrhythmias recorded during such a study may vary substantially from the spectrum recorded during another study. In addition, the values of specificity to detect supraventricular tachyarrhythmias derived from simulations performed and reported by each separate manufacturer do not allow for a correct comparison of the performance of different detection algorithms unless the database used for tachyarrhythmia episodes is uniform for all devices compared [7]. However, the databases used by different manufacturers are different. There is a good reason that these databases are not the same. Different algorithms and different programming of single-chamber criteria lead to a markedly different success in distinguishing true ventricular tachycardia (VT)/ventricular fibrillation (VF) episodes from supraventricular tachyarrhythmias at the level of ven-

March 2002 23 Table 1. Spectrum of tachyarrhythmias simulated. AV: Atrioventricular. VA = Ventriculo-atrial. Figure 1. Arrhythmia Simulator (ARSI, HKP, Germany). The device consists of the simulator itself (top) and the ICD adapter (DFA - 2DS, bottom). Pressing the <PR> button and any of the numbers on the simulator will start a group of tachyarrhythmias, e.g., AV nodal reentrant tachycardias with varying VA interval. Single or multiple atrial or ventricular extrasystoles may be delivered by pressing one of the 4 buttons at the far right of the panel. Even noise generated by alternating current or skeletal muscle can be generated. The adapter accommodates the ICD through the pocket created during device implantation, and even facilitates testing of an active can device. The ICD is attached via standard DF-1 connectors, mimicking the defibrillation electrodes, and IS-1 connectors for the pacing and sensing leads. tricular detection [8]. These differences result in a different spectrum of supraventricular tachyarrhythmias inappropriately classified by a single-chamber device and eventually stored in a database used to test the more sophisticated dual-chamber algorithms. At our institution, arrhythmias recorded from patients undergoing invasive electrophysiological studies and catheter ablation were used without any modifications to create a "tachyarrhythmia" library. The data consists of 71 supraventricular and 15 ventricular tachyarrhythmias recorded on a standard personal computer (PC) by measuring the P-P and R-R intervals of each episode including the preceding rhythm and onset of the arrhythmia. There are episodes of atrial fibrillation, atrial flutter with different atrioventricular (AV) conduction, typical and atypical AV nodal reentrant tachycardia, AV reentrant tachycardia, sinus tachycardia, and ventricular tachycardia with and without ventriculo-atrial (VA) conduction (Table 1). In order to cover the full spectrum of R-P and P-R intervals of typical and atypical AV nodal reentrant tachycardia, the VA interval was increased by increments of 20 ms from episode to episode. The atrial and ventricular sensing input of each DDD-ICD was connected to a custombuilt PC device that created rectangular impulses of a standardized amplitude of 20 mv and a duration of 10 ms at the intervals stored for each episode of tachyarrhythmia. Using this model, we compared the four DDD-ICDs available at this time: the Phylax AV (Biotronik, Germany), the Defender IV (Ela Medical, France), the Ventak AV III DR (Guidant, USA), and the Gem DR 7271 (Medtronic, USA). The results of this study have been reported elsewhere [9]. However, recently introduced dual-chamber detection algorithms include automatic delivery of a premature ventricular stimulus in order to test the presence of retrograde conduction or analysis of the morphology of the ventricular intracardiac electrogram (IEGM). This requires a more sophisticated simulation tool that has to be interactive in both directions and provides distinct ECG patterns for sinus rhythm and supraventricular, as well as ventricular tachycardia. For this purpose, we customized an Arrhythmia Simulator (ARSI, HKP, Germany). Materials and Methods The ARSI device (Figure 1) consists of the simulator itself and the ICD adapter, a box that accommodates

24 March 2002 Table 2. Technical data of the Arrhythmia Simulator (ARSI, HKP, Germany). the ICD (similar to the pocket created during device implantation) and even facilitates the testing of an active can device. The ICD is attached via standard DF-1 connectors, mimicking the defibrillation electrodes, and IS-1 connectors for the pacing and sensing leads. The simulator is a battery-driven device providing both a 12-lead surface ECG and an atrial and ventricular IEGM. Surface ECG and ventricular IEGMs provide different morphologies depending on the rhythm being simulated [10]. Each of the episodes of supraventricular rhythms can be delivered with narrow or wide QRS complexes. The simulation is fully interactive, i.e., in addition to simulating arrhythmias that are analyzed by the ICD connected to the simulator, the simulator responds to electrical impulses delivered by the ICD (stimulation, defibrillation). This even includes premature beats delivered after the effective refractory period that result in transient changes of tachycardia cycle length, thereby facilitating the evaluation of ICD algorithms that analyze the response to single premature beats. a Figure 2. SMART II algoritm of the Tachos (Biotronik, Germany) : Delivery of premature ventricular extrastimuli during two episodes of tachycardia with identical, stable cycle length and VA interval may result in shortening of the A-A interval indicating a ventricular tachycardia (panel a) or may leave the atrial cycle length unchanged indicating sinus tachycardia with first degree AV block (panel b). b

March 2002 25 Figure 3. P-R Logic algorithm of the Gem DR 7271 (Medtronic, USA). See text for further details. Results In the customized version of the simulator, there are more than 150 episodes from our library, covering the spectrum of tachyarrhythmias listed in Table 2. Some examples are sinus rhythm including supraventricular rhythm with normal, narrow QRS complexes, or wide QRS complexes in the presence of intraventricular conduction delay; ventricular tachycardia with wide QRS complexes with a different morphology as compared to supraventricular rhythms with wide QRS complexes, and irregular morphology in the presence of ventricular fibrillation. After the device is switched on, sinus rhythm is simulated. Amplitude of the surface ECG, basic heart rate, and the P-R interval may be varied. By pressing single buttons, transient AV block can be simulated or atrial or ventricular extrasystoles up to non-sustained tachycardias can be delivered. In addition, even noise generated by alternating current or skeletal muscle can be generated. Variation of the AV and VA interval of the simulated supraventricular and ventricular tachyarrhythmias reveals the impact of variations in the blanking time or zones defined for presumed antegrade or retrograde conduction during tachycardia. In the Parad+ algorithm of the Defender IV (Ela), the atrial signal in case of a typical AV nodal reentrant tachycardia with a VA interval less than the atrial blanking period is not detected and therefore the arrhythmia is classified as ventricular tachycardia However, if the VA interval during AV nodal reentrant tachycardia is longer than the atrial blanking period, the arrhythmia will be correctly classified as supraventricular tachycardia. The P-R Logic algorithm analyses the two previous R- R intervals for each ventricular event. The number of atrial events and their timing relative to the ventricular events are used to assign one of 19 couple codes to the most recent ventricular event. Zero, one, or more atrial events are classified within the first or second half of each R-R interval. If an atrial event is detected within 80 ms before or within 50 ms after a R wave, then that P wave should not be related to the ventricular event by either antegrade or retrograde conduction. However, any supraventricular tachycardia with a VA interval greater than 50 ms and less than 50% of the tachycardia cycle length will be classified as ventricular tachycardia with 1:1 VA conduction. Sinus tachycardia with AV block I and a P-R interval greater than 50% of the tachycardia cycle length will be classified as ventricular tachycardia with 1:1 VA conduction, too (Figure 3). Discussion Our simulator provides a convenient tool for easy assessment of the specificity of different ICD detection algorithms and a direct comparison of ICDs from different manufacturers. It may serve as the common universal database as suggested by Malik [7]. Wide acceptance of a database such as this would provide a uniform standard for evaluating the specificity for the correct classification of supraventricular tachyarrhythmias, and would result in values that are comparable among manufacturers. Due to its fully bi-directional interaction with the ICD, even testing of sophisticated detection algorithms that evaluate the response to a premature ventricular stimulus is feasible and the impact of the AV and VA interval on the accuracy for classification of tachyarrhythmias can be analyzed. While the accuracy of IEGM morphology analysis performed by the ICD algorithm cannot be studied, different electrogram morphologies can be simulated and the contribution of a morphology criterion to the overall performance of the algorithm can be assessed. Conclusion Sophisticated ICD algorithms may be difficult for a physician to understand without any specific arrhyth-

26 March 2002 mias illustrating the timecourse of application of the different detection criteria. Our device may help to train physicians by demonstrating the way a specific algorithm works. In addition, it is a valuable tool that aids the physician in choosing the ICD system with the optimal detection algorithm for a specific patient. The device simulates tachyarrhythmias similar to the patient's spontaneous arrhythmias and can help in determining which specific device should be implanted. References [1] Osswald S, Cron TA, Sterns L, et al. First clinical experience with a new ICD capable of dual-chamber sensing for differentiation of supraventricular tachyarrhythmias (abstract). PACE. 1997; 20: 1473 [2] Block M, et al. Dual-chamber implantable cardioverterdefibrillator Ventak AV - First results from the multicenter premarket release study (abstract). PACE. 1997; 20: 1473. [3] Lavergne T, Daubert JC, Chauvin M, et al. Preliminary clinical experience with the first dual-chamber pacemaker defibrillator. PACE.1997; 20: 182-188. [4] Swerdlow CD, Sheth NV, Olson WH. Clinical performance of a pattern-based, dual-chamber algorithm for discrimination of ventricular from supraventricular arrhythmias (abstract). PACE. 1998; 21: 800. [5] Kühlkamp V, Dörnberger V, Mewis C, et al. Clinical experience with the new detection algorithms for atrial fibrillation of a defibrillator with dual-chamber sensing and pacing. J Cardiovasc Electrophysiol. 1999; 10: 905-915. [6] Gillberg JM, Gunderson BD, Brown ML, et al. Dual-chamber versus single-chamber ventricular tachyarrhythmia detection. A retrospective comparison (abstract). PACE. 1998; 21: 909. [7] Malik M. Pitfalls of the concept of incremental specificity used in comparisons of dual-chamber VT / VF detection algorithms. PACE. 2000; 23: 1166-1170. [8] Anderson MH, et al. Performance of basic ventricular tachycardia detection algorithms in implantable cardioverter defibrillators: Implications for device programming. PACE. 1997; 20: 2975-2983. [9] Hintringer F, Schwarzacher S, Eibl G, et al. Inappropriate detection of supraventricular arrhythmias by implantable dual-chamber defibrillators: A comparison of four different algorithms. PACE. 2001; 24: 835-841. [10] Technical Manual "Arrhythmie Simulator ARSI - 2 D". HKP GmbH. 2001. Contact Dr. Florian Hintringer Universitätsklinik für Innere Medizin Klinische Abteilung für Kardiologie Anichstrasse 35 A-6020 Innsbruck Austria Tel.: +43 512 5043255 Fax: +43 512 5043379 E-mail: florian.hintringer@uklibk.ac.at