MRI Information for Medtronic Spinal and Biologics Devices

Similar documents
DISTAL RADIUS. Instructions for Use

Low-Profile Wrist Fixator. For stabilization of fractures of the distal radius.

HawkeyeTM Peek. surgical technique

nva Anterior Lumbar Interbody Fusion System

Medium External Fixator Pediatric Femoral Shaft Frame. Using medium multi-pin clamps.

nvt Transforaminal Lumbar Interbody Fusion System

nvp Posterior Lumbar Interbody Fusion System

Cervical Spacer System surgical technique

*smith&nephew. MRI Safety Information & Parameters for Smith & Nephew Orthopaedics AG. Knee Implants

MRI Guidelines for the Axonics Sacral Neuromodulation System

External Distal Radius Fixator. Supplement to the 8 mm rod fixator system

Algovita. MRI Procedure Guidelines. Spinal Cord Stimulation System. 201x

Medium External Fixator Humeral Shaft Frame. Modular frame for upper extremity use.

Solitaire Anterior Spinal System

C-THRU Anterior Spinal System

OPERATIVE TECHNIQUE. anterior cervical plating system

OPERATIVE TECHNIQUE. CONSTRUX Mini PTC. Mini PTC Spacer System

Hinged Laminoplasty System surgical technique

Micra MC1VR01. MRI procedural information for Micra Model MC1VR01 MR Conditional single chamber transcatheter pacing device (VVIR)

*smith&nephew. MRI Safety Information & Parameters for Smith & Nephew Orthopaedics AG. Shoulder Implants

Read this manual before performing an MRI scan on a patient implanted with an Algovita Spinal Cord Stimulation System.

Zimmer Anterior Buttress Plate System. Surgical Technique

TABLE OF CONTENTS. Vault C Anterior Cervical Discectomy 2 and Fusion (ACDF) System Overview. Implants 3. Instruments 5. Surgical Technique 10

Alamo C. Cervical Interbody System Surgical Technique. An Alliance Partners Company

TABLE OF CONTENTS. ShurFit Anterior Cervical Interbody Fusion (ACIF) System Overview 2. Implant Specifications 3. Instrument Features 4

Apache Cervical Interbody Fusion Device. Surgical Technique. Page of 13. LC-005 Rev F

July 10, X-spine Systems, Incorporated David Kirschman, MD Chief Medical Officer 452 Alexandersville Road Miamisburg, Ohio 45342

EasyStep. Operative technique

EFSPINE CERVICAL COMBINED SET DISC PROTHESIS ORGANIZER BOX

*smith&nephew. MRI Safety Information & Parameters for Smith & Nephew Orthopaedics AG. Hip Implants

WallFlex Biliary RX Partially Covered Stent System Prescriptive Information

PACH PLATE 2 OR 4 HOLE FIXATION

A U X I L I A R Y C O N N E C T O R S Surgical Technique

MRI GUIDELINES FOR INSPIRE THERAPY

Instructions for use Prodisc -C Vivo Cervical disc prosthesis

Replacement Heart Valve Product Description (Stented Tissue) Models Reference

REIMBURSEMENT GUIDE. Sovereign. Spinal System

The Calcaneal Plate. The Synthes non-locking solution for the Calcaneus.

Table of Contents.

OBSOLETED. LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

CROSS -FUSE P E E K V B R / I B F SYST E M

GIZA Surgical Technique

EXACTECH SPINE. Operative Technique. Cervical Spacer System. Surgeon focused. Patient driven. TM

Allium Trans-hepatic Biliary Stent (BIS)

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500)

Fusion Device. Surgical Technique. Cervical Interbody Fusion with Trabecular Metal Technology

TM TM Surgical Technique

LCP Metaphyseal Plates. For extra-articular fractures.

Alamo T Transforaminal Lumbar Interbody System Surgical Technique

Surgical Technique. Apache Anterior Lumbar Interbody Fusion

Spinal Correction FRA Spacers. Angled and parallel spacers designed for a lateral approach.

ImageReady MRI Full Body Guidelines for Precision Montage MRI Spinal Cord Stimulator System

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System

Royal Oak Cervical Plate System

100 Interpace Parkway Parsippany, NJ

VLIFT System Overview. Vertebral Body Replacement System

product overview Implant heights range from 8mm-20mm in 2mm increments, with two lordocic angle options of 6 and 12.

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500)

SURGICAL TECHNIQUE GUIDE TRESTLE. Anterior Cervical Plating System

SURGICAL TECHNIQUE MANUAL. InterFuse T

ANJON BREMER LIGHT VEST

FastFrame External Fixation System. Damage Control Surgical Technique

Replacement Heart Valve Product Description (Stented Tissue) Models Reference

VNS Therapy System Physician s Manual

MRI GUIDELINES FOR INSPIRE THERAPY

North Medical Endoscopic Biliary Stent (BilS)

REIMBURSEMENT GUIDE. Sovereign. Spinal System

LCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius.

O.I.C. PEEK UniLIF Unilateral Lumbar Interbody Fusion

Large External Fixator Modular Knee Bridge. Using multi-pin clamps.

Zimmer Trabecular Metal Ankle Interpositional Spacer and Trabecular Metal Ankle Fusion Spacer

PARADIGM SPINE. Anterior Cervical Fusion Cage. Cervical Interbody Fusion

Revision A Date:

Oracle Spacer. A PEEK spacer for lateral lumbar interbody fusion.

Aesculap CeSpace TM PEEK and CeSpace TM XP Spinal Implant System Instructions for Use

Technique Guide. Zero-P VA. Variable angle zero-profile anterior cervical interbody fusion (ACIF) device.

Distal Radius Plate 2.4/2.7 dorsal and volar

Trinica and Trinica Select Anterior Cervical Plate System

Royal Oak IBFD System Surgical Technique Posterior Lumbar Interbody Fusion (PLIF)

Thoracolumbar Spine Locking Plate (TSLP) System. A low-profile plating system for anterior stabilization of the thoracic and lumbar spine.

L-VARLOCK. Posterior Lumbar Cage with adjustable lordosis. S urgical T echnique

2014 AAPM 56 th Annual Meeting

Sterile-Packaged Large External Fixator Kits. For treatment of long bone and pelvic fractures that require external fixation.

Talos -C (HA) and the PEEK-OPTIMA HA Enhanced Technology

Button Plate. Reinforcement for transosseous fixations.

ACP1 CERVICAL PLATE SPINAL SYSTEM SURGICAL TECHNIQUE GUIDE II.

ImageReady MRI Head Only Guidelines for Spectra WaveWriter Spinal Cord Stimulator System

Synex System TECHNIQUE GUIDE. An expandable vertebral body replacement device

INFUSE Bone Graft/ LT-CAGE Lumbar Tapered Fusion Device. Patient Information

Large External Fixator Modular Knee Bridge

JRI Thompson Hemiarthroplasty

Cervical Solutions. Optio-C Anterior Cervical PEEK. Interbody System. Surgical Technique Guide

ACP. Anterior Cervical Plate System SURGICAL TECHNIQUE

Veyron -C Anterior Cervical System Surgical Technique

Zero-P Instruments and Implants. Zero-profile anterior cervical interbody fusion (ACIF) device.

BAK/C Cervical Anterior Interbody Fusion System

MEFiSTO. Monolateral External Fixation System for Trauma and Orthopaedics.

Cervical Solutions. Alta. ACDF System. Surgical Technique Guide

Transcription:

M708348B263E Rev C Release Date: 2013-02 MRI Information for Medtronic Spinal and Biologics Devices Not for Distribution in the U.S or its territories. 1 P age

Table of Contents MRI Information for Medtronic Spinal Biologics Implants... 3 Cervical Disc PRESTIGE ST Cervical Disc... 4 PRESTIGE LP Cervical Disc... 6 Cervical Interbody Fusion PEEK PREVAIL Cervical Interbody Device... 8 Lumber Disc MAVERICK Replacement System... 11 Lumbar Interbody LT-CAGE Device... 13 SOVEREIGN Spinal System... 15 Lumbar Fusion Plate PYRAMID Anterior Lumbar Plate... 18 SMA Staples... 20 Untested Implants (Rationales)... 22 2 P age

MRI Information for Medtronic Spinal Biologics Implants Metallic objects may pose problems for the use of Magnetic Resonance Imaging (MRI) due to displacement forces and torque, excessive implant heating, and image artifacts. Medtronic Spinal and Biologics implants that were deemed to be worst case in terms of materials and metallic volumes were evaluated for MRI-related issues. Testing was conducted using either a 1.5 Tesla and/or 3-Tesla MR system. The specific implants listed in this document have all been classified as MR-Conditional in accordance with American Society for Testing Materials International, F2503-05, Standard Practice for Marking Medical Device and Other Items for Safety in the Magnetic Resonance Environment. All devices labeled as MR-Conditional pose no known MRI-related hazards or additional risks to patients under these specific testing conditions. MRI assessment summaries for tested Medtronic Spinal and Biologics implants are provided in this document where details about static magnetic fields, implant heating, and artifact information can be found. For information about specific products, please contact Medtronic. 3 P age

Cervical Disc PRESTIGE ST Cervical Disc DESCRIPTION The PRESTIGE Cervical Disc is a two-piece articulating metal-on-metal device that is inserted into the intervertebral disc space at a single cervical level using an anterior approach. The device is manufactured from wrought type 316 stainless steel (ASTM F-138) and consists of two metal plates which function via a ball and trough mechanism. The superior component of the implant contains the ball portion of the mechanism, and the inferior component incorporates the trough portion. The flat portion of each component, which contacts the vertebral endplate, is roughened through a grit blasting process. Each component is affixed to the vertebral body by two bone screws through an anterior fang. The bone screws are held in place by a lock screw mechanism. In the implanted disc, the bone screws are divergent in the cephalic/caudal direction and convergent in the medial/lateral direction. 4 P age

MRI Information PRESTIGE ST Cervical Disc Non-clinical testing demonstrated that the PRESTIGE ST Cervical Disc System is MR Conditional. A patient with this device can be scanned safely immediately after placement under the following conditions: Static Magnetic Field -Static magnetic field of 3-Tesla or less -Maximum spatial gradient magnetic field of 720-Gauss/cm or less MRI-Related Heating In non-clinical testing, the PRESTIGE ST Cervical Disc System produced the following temperature rise during MRI performed for 15 min of scanning (i.e., per pulse sequence) in the 3-Tesla (3- Tesla/128-MHz, Excite, HDx, Software 14X.M5, General Electric Healthcare, Milwaukee, WI) MR system: Highest temperature change +1.8 C Therefore, the MRI-related heating experiments for the PRESTIGE ST Cervical Disc System at 3- Tesla using a transmit/receive RF body coil at an MR system reported whole body averaged SAR of 2.9 -W/kg (i.e., associated with a calorimetry measured whole body averaged value of 2.7-W/kg) indicated that the greatest amount of heating that occurred in association with these specific conditions was equal to or less than +1.8 C. An MRI-heating test lower than 3-Tesla/128-MHz has not been evaluated. Artifact Information MR image quality may be compromised if the area of interest is in the same area or relatively close to the position of the PRESTIGE ST Cervical Disc System. The artifact size information is as follows: Pulse sequence T1-SE T1-SE GRE GRE Signal Void Size 4,989 mm 2 2,950 mm 2 9,596 mm 2 13,770 mm 2 Imaging Plane parallel perpendicular parallel perpendicular Therefore, optimization of MR imaging parameters to compensate for the presence of this device may be necessary. 5 P age

Cervical Disc PRESTIGE LP Cervical Disc DESCRIPTION The PRESTIGE LP Cervical Disc consists of two articulating components which are available in various sizes. The device is made of titanium alloy/titanium carbide composite. 6 P age

MRI Information PRESTIGE LP Cervical Disc Non-clinical testing demonstrated that the PRESTIGE LP Cervical Disc System implant is MR Conditional. A patient with this device can be scanned safely immediately after placement under the following conditions: Static Magnetic Field -Static magnetic field of 3-Tesla or less -Maximum spatial gradient magnetic field of 720-Gauss/cm or less MRI-Related Heating In non-clinical testing, the PRESTIGE LP Cervical Disc System implant produced the following temperature rise during MRI performed for 15 min of scanning (i.e., per pulse sequence) in the 3-Tesla (3-Tesla/128-MHz, Excite, HDx, Software 14X.M5, General Electric Healthcare, Milwaukee, WI). MR system: Highest temperature change +1.6 C Therefore, the MRI-related heating experiments for the PRESTIGE LP Cervical Disc System implant at 3-Tesla using a transmit/receive RF body coil at an MR system reported whole body averaged SAR of 2.9 -W/kg (i.e., associated with a calorimetry measured whole body averaged value of 2.7-W/kg) indicated that the greatest amount of heating that occurred in association with these specific conditions was equal to or less than +1.6 C. An MRI-heating test lower than 3-Tesla/128-MHz has not been evaluated. Artifact Information MR image quality may be compromised if the area of interest is in the same area or relatively close to the position of the PRESTIGE LP Cervical Disc System implant. The artifact size information is as follows: Pulse sequence T1-SE T1-SE GRE GRE Signal Void Size 1,401 mm 2 1,093 mm 2 2,101 mm 2 2,422 mm 2 Imaging Plane parallel perpendicular parallel perpendicular Therefore, optimization of MR imaging parameters to compensate for the presence of this device may be necessary. 7 P age

Cervical Interbody Fusion PEEK PREVAIL Cervical Interbody Device DESCRIPTION The PEEK PREVAIL Cervical Interbody Device is an intervertebral body fusion device with internal screw fixation. The screws protrude through the interbody portion of the device and stabilize the vertebral body while preventing expulsion of the implant. The implant is I-Beam shaped with a 2 screw midline configuration. This device is intended to be radiolucent and the interior space of the product is to be used with autograft. The PEEK PREVAIL Cervical Interbody device implant is manufactured from PEEK Optima LT1 and contains tantalum radiopaque markers and a Nitinol screw locking mechanism. The screws used with this device (ZEPHIR Anterior Cervical Screws) are manufactured from Titanium Alloy. 8 P age

PEEK PREVAIL Cervical Interbody Device MRI INFORMATION The PEEK PREVAIL Cervical Interbody Device was determined to be MR-Conditional based on non-clinical testing and comparison to previously evaluated Medtronic products. A patient with this device can be safely scanned immediately after device placement under the following conditions. Static Magnetic Field Static magnetic field of 1.5 Tesla and 3 Tesla. Maximum spatial gradient magnetic field of 3000 Gauss/cm or less Maximum whole body average specific absorption rate (SAR) of 2.0 W/kg or less under Normal Operating Mode, for 15 minutes of scanning per pulse sequence. MRI-Related Heating In non-clinical testing, a worst case interbody device representative of the PEEK PREVAIL Cervical Interbody Device produced the following temperature rises during an MRI (Magnetic Resonance Imaging) performed for 15 minutes of scanning (i.e., per pulse sequence) in 1.5 Tesla/64 MHz MR system (Magnetom, Siemens Medical Solutions, Malvern, PA. Software Numaris/4, Version Syngo MR 2002B DHHS Active-shielded, horizontal field scanner) and 3 Tesla/128 MHz (Excite, HDx, Software 14X.M5, General Electric Healthcare, Milwaukee, WI. Active-shielded, horizontal field scanner) MR systems: 1.5 Tesla 3 Tesla MR system reported, whole body average SAR 2.9 W/kg 2.9 W/kg Calormetry Measured values, whole body averaged SAR 2.1 W/kg 2.7 W/kg Highest temperature change 1. 5 C 1. 9 C Artifact Information MR image quality may be compromised if the area of interest is in the same area or relatively close to the position of the PEEK PREVAIL Cervical Interbody Device. Therefore, optimization of MR imaging parameters to compensate for the presence of this device may be necessary. MRI Patient Counseling Information Physicians should communicate with the patient the following information about MRI with respect to the PEEK PREVAIL Cervical Interbody Device: o PEEK PREVAIL Cervical Interbody Device performance has been established for MRI systems at field strengths of 1.5 Tesla and 3.0 Tesla. o During an MRI, the patient may notice a warming sensation around the implant or feel a tingling sensation. If the warming or tingling sensation is uncomfortable, the patient should communicate this to the MR technologist, the MRI should be stopped, and the settings adjusted to reduce or eliminate the sensation. The highest temperature change observed in non-clinical testing was +1.9 ºC (associated with specific conditions previously listed). o Additionally, the metal in the implant may cause the MRI image to be distorted in the area around the implant. The MRI can be adjusted to minimize the image distortion. 9 P age

Physicians should instruct patients to: o Inform any healthcare personnel (e.g., doctor or MR technologist) that an implanted interbody device exists prior to receiving an MRI. o The patient s doctor will recommend whether or not an MRI is appropriate. If PEEK PREVAIL Cervical Interbody Device is used in connection with any device which is not MR Conditional, please be advised that this combination has not been tested in the MR environment and, therefore, higher heating and possible injury to the patient may occur. 10 P age

Lumber Disc MAVERICK Total Disc Replacement System DESCRIPTION The MAVERICK Total Disc Replacement System consists of two cobalt-chromium molybdenum alloy articulating components. The two components each have one polished articulating side and one roughened, hydroxypatite-coated bone-contacting side. The male (inferior) component and female (superior) component are available in three footprints to meet the anatomical needs of the patients (i.e., Small, Medium, and Large). Both endplates may be pre-angled either 3º or 6º. The male component is available in only one height, but the female (superior) component is offered in several heights. Different size (female and male) components can be used in combination with each other. Therefore, the surgeon is able to interchange components to build a wide configuration of constructs. The MAVERICK implant components are fabricated from medical grade cobalt-chromiummolybdenum alloys described by ASTM F-1537. 11 P age

MRI Information MAVERICK Total Disc Replacement System Non-clinical testing demonstrated that the MAVERICK Disc Replacement System is MR Conditional. A patient with this device can be scanned safely immediately after placement under the following conditions: Static Magnetic Field -Static magnetic field of 3-Tesla or less -Maximum spatial gradient magnetic field of 720-Gauss/cm or less MRI-Related Heating In non-clinical testing, the MAVERICK Disc Replacement System produced the following temperature rise during MRI performed for 15 min of scanning (i.e., per pulse sequence) in the 3-Tesla (3-Tesla/128-MHz, Excite, HDx, Software 14X.M5, General Electric Healthcare, Milwaukee, WI) MR system: Highest temperature change +1.8 C Therefore, the MRI-related heating experiments for the MAVERICK Disc Replacement System at 3-Tesla using a transmit/receive RF body coil at an MR system reported whole body averaged SAR of 2.9 -W/kg (i.e., associated with a calorimetry measured whole body averaged value of 2.7-W/kg) indicated that the greatest amount of heating that occurred in association with these specific conditions was equal to or less than +1.8 C. An MRI-heating test for a static magnetic field less than 3-Tesla has not been evaluated. Artifact Information MR image quality may be compromised if the area of interest is in the same area or relatively close to the position of the MAVERICK Replacement System. The artifact size information is as follows: Pulse sequence T1-SE T1-SE GRE GRE Signal Void Size 9,799 mm 2 6,933 mm 2 13,513 mm 2 12,799 mm 2 Imaging Plane parallel perpendicular parallel perpendicular Therefore, optimization of MR imaging parameters to compensate for the presence of this device may be necessary. 12 P age

Lumbar Interbody LT-CAGE Device DESCRIPTION The LT-CAGE Lumbar Tapered Fusion Device and the LT-CAGE PEEK Lumbar Tapered Fusion Device consist of hollow, perforated, machined cylinders with opposing flats. The cages have a tapered design with an angle of 8.8 and are available in diameters ranging from 14 mm to 18 mm at the narrow end of the taper, 17 to 22 mm at the wide end of the taper, and in lengths ranging from 20 mm to 26mm. There are two holes on each of the two flat sides. On each of the two rounded aspects, there is a single rounded slot. The implants have a helical screw thread on the outer surface. One end of the device is closed. The other end is open to be filled with bone graft and is used to engage the drive instrument for insertion of the device. The LT-CAGE Lumbar Tapered Fusion Device implant is made from implant grade titanium alloy (Ti-6Al-4V) described by such standards as ASTM F136 or its ISO equivalent. Alternatively, the tapered device can be made from Polyetheretherketone, with the trade name of PEEK-OPTIMA LT1. This device is known as the LT-CAGE PEEK Lumbar Tapered Fusion Device. 13 P age

MRI Information LT-CAGE Device Non-clinical testing demonstrated that the LT CAGE Lumbar Tapered Fusion Device Implant is MR Conditional. A patient with this device can be scanned safely immediately after placement under the following conditions: Static Magnetic Field -Static magnetic field of 3-Tesla or less -Maximum spatial gradient magnetic field of 720-Gauss/cm or less MRI-Related Heating In non-clinical testing, the LT-CAGE Lumbar Tapered Fusion Device implant produced the following temperature rise during MRI performed for 15 min of scanning (i.e., per pulse sequence) in the 3-Tesla (3-Tesla/128-MHz, Excite, HDx, Software 14X.M5, General Electric Healthcare, Milwaukee, WI) MR system: Highest temperature change +1.6 C Therefore, the MRI-related heating experiments for the LT-CAGE Lumbar Tapered Fusion Device implant at 3-Tesla using a transmit/receive RF body coil at an MR system reported whole body averaged SAR of 2.9 -W/kg (i.e., associated with a calorimetry measured whole body averaged value of 2.7-W/kg) indicated that the greatest amount of heating that occurred in association with these specific conditions was equal to or less than +1.6 C. An MRI-heating test for a static magnetic field less than 3-Tesla has not been evaluated. Artifact Information MR image quality may be compromised if the area of interest is in the same area or relatively close to the position of the LT-CAGE Lumbar Tapered Fusion Device Implant. The artifact size information is as follows: Pulse sequence T1-SE T1-SE GRE GRE Signal Void Size 1,437 mm 2 990 mm 2 2,347 mm 2 4,253 mm 2 Imaging Plane parallel perpendicular parallel perpendicular Therefore, optimization of MR imaging parameters to compensate for the presence of this device may be necessary. 14 P age

Lumber Interbody SOVEREIGN Spinal System DESCRIPTION The SOVEREIGN Spinal System is an intervertebral body fusion device with internal screw fixation. The screws protrude through the interbody portion of the device and stabilize the vertebral body while preventing expulsion of the implant. The implant is lens-shaped with three holes for placement of titanium screws. If the physician chooses to use screws with the implant, the accompanying cover plate must be used. This device is intended to be radiolucent and the interior space of the product is to be used with bone graft. The SOVEREIGN Spinal System interbody device is manufactured from PEEK Optima (polyetheretherketone) and contains tantalum radiopaque markers. The screws used with this device are manufactured from titanium alloy. 15 P age

SOVEREIGN Spinal System MRI Information -The following information is included in the packaged device. In non-clinical testing the SOVEREIGN TM Spinal System was determined to be MR-conditional. A patient with this device can be scanned safely immediately after placement under the following conditions: Static Magnetic Field - Static magnetic field of 1.5 Tesla and 3-Tesla. - Maximum spatial gradient magnetic field of 3000-Gauss/cm or less - Maximum whole body average specific absorption rate (SAR) of 2.0 -W/kg or less under Normal Operating Mode, for 15 minutes of scanning per pulse sequence. MRI-Related Heating In non-clinical testing, the SOVEREIGN TM Spinal System produced the following temperature rises during MRI performed for 15-min of scanning (i.e., per pulse sequence) in 1.5-Tesla/64-MHz MR system (Magnetom, Siemens Medical Solutions, Malvern, PA. Software Numaris/4, Version Syngo MR 2002B DHHS Activeshielded, horizontal field scanner) and 3-Tesla/128-MHz (Excite, HDx, Software 14X.M5, General Electric Healthcare, Milwaukee, WI) MR systems: 1.5-Tesla 3-Tesla MR system reported, whole body averaged SAR 2.9-W/kg 2.9-W/kg Calorimetry measured values, whole body averaged SAR 2.1-W/kg 2.7-W/kg Highest temperature change +1.8 C +1.7 C Artifact Information MR image quality may be compromised if the area of interest is in the same area or relatively close to the position of the SOVEREIGN TM Spinal System. The artifact size information is, as follows: 16 P age

Pulse sequence T1-SE T1-SE GRE GRE Signal Void Size 1,540-mm 2 1,397-mm 2 3,595-mm 2 3,782-mm 2 Imaging Plane parallel perpendicular parallel perpendicular Therefore, optimization of MR imaging parameters to compensate for the presence of this device may be necessary. The maximum artifact size (i.e., as seen on the gradient echo pulse sequence) extends approximately 20-mm relative to the size and shape of the SOVEREIGN TM Spinal System. MRI Patient Counseling Information Physicians should communicate with the patient the following information about Magnetic Resonance Imaging (MRI) with respect to the SOVEREIGN TM Spinal System: SOVEREIGN TM Spinal System performance has been established for MRI systems at field strengths of 1.5 Tesla and 3.0 Tesla. During and MRI the patient may notice a warming sensation around the implant or feel a tingling sensation. If the warming or tingling sensation is uncomfortable the patient should communicate this to the MR technologist, the MRI should be stopped, and the settings adjusted to reduce or eliminate the sensation. The highest temperature change observed in non-clinical testing was +1.8ºC (associated with specific conditions listed above). Additionally, the metal in the implant may cause the MRI image to be distorted in the area around the implant. The MRI can be adjusted to minimize the image distortion. Physicians should instruct patients to: Inform any healthcare personnel (e.g. doctor or MR technologist) that they have an implanted interbody device prior to receiving and MRI. The patient s doctor will recommend whether or not an MRI is appropriate. If SOVEREIGN TM Spinal System is used in connection with any device which is not MR Conditional, please be advised that this combination has not been tested in the MR environment and, therefore, higher heating and possible injury to the patient may occur. 17 P age

Lumbar Fusion Plate PYRAMID Anterior Lumbar Plate DESCRIPTION The PYRAMID +4 ANTERIOR LUMBAR PLATE System is a supplemental fixation device consisting of a variety of shapes and sizes of plates, and screws, as well as ancillary products and instrument sets. The PYRAMID +4 ANTERIOR LUMBAR PLATE System components can be locked into a variety of configurations, with each construct being tailor-made for the individual case. As with all orthopedic and neurosurgical implants, none of the PYRAMID +4 ANTERIOR LUMBAR PLATE Fixation System components should ever be reused under any circumstances. PYRAMID +4 ANTERIOR LUMBAR PLATE System implant components are made of titanium alloy. Stainless steel and titanium implant components must not be used together in a construct. 18 P age

MRI Information PYRAMID Anterior Lumbar Plate Non-clinical testing demonstrated that the PYRAMID Anterior Lumbar Plate and screws is MR Conditional. A patient with this device can be scanned safely immediately after placement under the following conditions: Static Magnetic Field -Static magnetic field of 3-Tesla or less -Maximum spatial gradient magnetic field of 720-Gauss/cm or less MRI-Related Heating In non-clinical testing, the PYRAMID Anterior Lumbar Plate and screws produced the following temperature rise during MRI performed for 15 min of scanning (i.e., per pulse sequence) in the 3-Tesla (3-Tesla/128-MHz, Excite, HDx, Software 14X.M5, General Electric Healthcare, Milwaukee, WI) MR system: Highest temperature change +1.9 C Therefore, the MRI-related heating experiments for the PYRAMID Anterior Lumbar Plate and screws at 3-Tesla using a transmit/receive RF body coil at an MR system reported whole body averaged SAR of 2.9 -W/kg (i.e., associated with a calorimetry measured whole body averaged value of 2.7-W/kg) indicated that the greatest amount of heating that occurred in association with these specific conditions was equal to or less than +1.9 C. An MRI-heating test for a static magnetic field less than 3-Tesla has not been evaluated. Artifact Information MR image quality may be compromised if the area of interest is in the same area or relatively close to the position of the PYRAMID Anterior Lumbar Plate and screws. The artifact size information is as follows: Pulse sequence T1-SE T1-SE GRE GRE Signal Void Size 3,249 mm 2 2,585 mm 2 5,905 mm 2 4,899 mm 2 Imaging Plane parallel perpendicular parallel perpendicular Therefore, optimization of MR imaging parameters to compensate for the presence of this device may be necessary. 19 P age

Lumbar Fusion Plate SMA Staples PURPOSE The Medtronic Sofamor Danek SPINAL STAPLE System is intended to be an implant system used for treatment of thoracic and/or lumbar scoliosis and other deformities of the spine (i.e., kyphosis and/or lordosis). DESCRIPTION All of the implants are made of Shape Memory Alloy (Nitinol - NiTi). Shape Memory Alloy (SMA) is compatible with titanium implants only. Do not use with stainless steel. Never use stainless steel and titanium implant components in the same construct. To achieve best results, do not use any of the Medtronic Sofamor Danek SPINAL STAPLE System implants with or without graft with implants from any other system or manufacturer unless specifically allowed to do so in this, or another Medtronic Sofamor Danek document. As with all orthopedic implants, none of the Medtronic Sofamor Danek SPINAL STAPLE System implants should ever be reused under any circumstances. 20 P age

MRI Information SMA Staples Non-clinical testing demonstrated that the SMA Staple is MR Conditional. A patient with this device can be scanned safely immediately after placement under the following conditions: Static Magnetic Field -Static magnetic field of 3-Tesla or less -Maximum spatial gradient magnetic field of 720-Gauss/cm or less MRI-Related Heating In non-clinical testing, the SMA Staple produced the following temperature rise during MRI performed for 15 min of scanning (i.e., per pulse sequence) in the 3-Tesla (3-Tesla/128-MHz, Excite, HDx, Software 14X.M5, General Electric Healthcare, Milwaukee, WI) MR system: Highest temperature change +1.6 C Therefore, the MRI-related heating experiments for the SMA Staple at 3-Tesla using a transmit/receive RF body coil at an MR system reported whole body averaged SAR of 2.9 -W/kg (i.e., associated with a calorimetry measured whole body averaged value of 2.7-W/kg) indicated that the greatest amount of heating that occurred in association with these specific conditions was equal to or less than +1.6 C. An MRI-heating test for a static magnetic field less than 3-Tesla has not been evaluated. Artifact Information MR image quality may be compromised if the area of interest is in the same area or relatively close to the position of the SMA Staple. The artifact size information is as follows: Pulse sequence T1-SE T1-SE GRE GRE Signal Void Size 1,460 mm 2 1,016 mm 2 2,482 mm 2 1,919 mm 2 Imaging Plane parallel perpendicular parallel perpendicular Therefore, optimization of MR imaging parameters to compensate for the presence of this device may be necessary. 21 P age

Untested Implants (Rationales) Not all Medtronic Spinal and Biologics devices were evaluated for MRI-related issues. The implants and/or systems that were deemed to be worst case in terms of materials and metallic volumes were evaluated for MRI-related issues. For devices not evaluated, engineering rationales were completed to compare these devices to a previously evaluated Medtronic product. The following table indicates what the worst-case system is for the devices that were not evaluated for MRI-related issues, but have an engineering rationale to adopt the results of the Worst Case System. Spinal System Worst Case Spinal System TELAMON PEEK System CRESENT PEEK Spinal System CAPSTONE CONTROL Spinal System ANATOMIC PEEK Cervical Fusion System CORNERSTONE PSR Spacer CLYDESDALE PEEK Spacer PERIMETER System PERIMETER -C System INTREPID System CD HORIZON SPIRE Stabilization System TELAMON Titanium Spacer AFFINITY Cage System INTER FIX RP Fusion System SOVEREIGN Spinal System X-STOP Spinal System LT - CAGE Lumbar Cage 22 P age

Please see device-specific package insert for a complete listing of indications, contraindications, warnings, and precautions. CUSTOMER SERVICE INFORMATION: ADDRESS TELEPHONE Medtronic, Inc. 1800 Pyramid Place Memphis, TN 38132 800 933 2635 (In U.S.A) 901 396 3133 (Outside U.S.A) 901 396 0356 Fax Medtronic B.V. + 31 45 566 80 00 Earl Bakkenstraat 6422 PJ Heerlen The Netherlands 2013 Medtronic Sofamor Danek USA, Inc. All rights reserved. 23 P age