New Mass Spectrometry Tools to Transform Metabolomics and Lipidomics

Similar documents
New Instruments and Services

Michal Godula Thermo Fisher Scientific. The world leader in serving science

Don t miss a thing on your peptide mapping journey How to get full coverage peptide maps using high resolution accurate mass spectrometry

New Instruments and Services

Go beyond. to realities unexplored. Comprehensive workflows, integrated solutions

Advances in Hybrid Mass Spectrometry

for new contaminants at ultra trace level by using high resolution mass spectrometry

Supporting information

Increased Identification Coverage and Throughput for Complex Lipidomes

MASS SPECTROMETRY BASED METABOLOMICS. Pavel Aronov. ABRF2010 Metabolomics Research Group March 21, 2010

Orbitrap ID-X Tribrid mass spectrometer. Transforming small molecule identification and characterization

Thermo Scientific LCMS Solutions for Pesticide Analysis

LC/MS/MS SOLUTIONS FOR LIPIDOMICS. Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS

Research to Routine Workflows for Large and Small Molecules using the Q Exactive HR/MS

Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System

Thermo Scientific LipidSearch Software for Lipidomics Workflows. Automated Identification and Relative. Quantitation of Lipids by LC/MS

Metabolomic and Proteomics Solutions for Integrated Biology. Christine Miller Omics Market Manager ASMS 2015

Discovery Metabolomics - Quantitative Profiling of the Metabolome using TripleTOF Technology

NON TARGETED SEARCHING FOR FOOD

Bioanalytical Quantitation of Biotherapeutics Using Intact Protein vs. Proteolytic Peptides by LC-HR/AM on a Q Exactive MS

Metabolite identification in metabolomics: Metlin Database and interpretation of MSMS spectra

Metabolite identification in metabolomics: Database and interpretation of MSMS spectra

SIEVE 2.1 Proteomics Example

Mass Spectrometry Infrastructure

Amadeo R. Fernández-Alba

Towards High Resolution MS in Regulated Bioanalysis

Join the mass movement towards mass spectrometry

Target Analyses in Parallel Reaction Monitoring Mode (PRM)

Glycerolipid Analysis. LC/MS/MS Analytical Services

Mass Spectrometry based metabolomics

Agilent 7700x ICP-MS

Introduction to the Oligo HTCS Systems. Novatia, LLC

Quadrupole and Ion Trap Mass Analysers and an introduction to Resolution

Quantitative Analysis of Drugs of Abuse in Urine using UHPLC Coupled to Accurate Mass AxION 2 TOF Mass Spectrometer

Ultra High Definition Optimizing all Analytical Dimensions

MALDI Imaging Drug Imaging Detlev Suckau Head of R&D MALDI Bruker Daltonik GmbH. December 19,

Agilent s LC/MS Portfolio and Applications Examples

Workflows in SIEVE and LipidSearch

Characterization of an Unknown Compound Using the LTQ Orbitrap

Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations

THE POWER OF MASS SPECTROMETRY FOR IC ANALYTICAL CHEMISTS. Unleash New Possibilities with Enhanced Detection for IC Applications

Benefits and Characteristic Applications of High Resolution GC/MS and LC/MS. Frank David RIC and Ghent University

The Agilent MassHunter Software. One Software for all Agilent Mass Spec Systems

Impurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF

Proteomics of body liquids as a source for potential methods for medical diagnostics Prof. Dr. Evgeny Nikolaev

Application Note # LCMS-89 High quantification efficiency in plasma targeted proteomics with a full-capability discovery Q-TOF platform

Targeted and untargeted metabolic profiling by incorporating scanning FAIMS into LC-MS. Kayleigh Arthur

amazon speed Innovation with Integrity Ion Trap Performance Beyond Imagination Ion Trap MS

Improving Selectivity in Quantitative Analysis Using MS 3 on a Hybrid Quadrupole-Linear Ion Trap Mass Spectrometer

2. Ionization Sources 3. Mass Analyzers 4. Tandem Mass Spectrometry

MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager

The Comparison of High Resolution MS with Triple Quadrupole MS for the Analysis of Oligonucleotides

amazon Turning Speed into Solutions

MS/MS Scan Modes. Eötvös University, Budapest April 16, MS/MS Scan Modes. Árpád Somogyi. Product Ion Scan Select. Scan. Precursor Ion Scan Scan

For personal use only. Please do not reuse or reproduce

Designer Fentanyls Drugs that kill and how to detect them. Cyclopropylfentanyl

The use of mass spectrometry in lipidomics. Outlines

Automating Mass Spectrometry-Based Quantitative Glycomics using Tandem Mass Tag (TMT) Reagents with SimGlycan

More structural information with MS n

Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification

Experiences with application of full scan high resolution MS for pesticide residue analysis

LC/QTOF Discovery of Previously Unreported Microcystins in Alberta Lake Waters

Edgar Naegele. Abstract

UPLC-HRMS: A tool for multi-residue veterinary drug methods

Analytical Workflow for Extractable and Leachable Impurities

Ion Source. Mass Analyzer. Detector. intensity. mass/charge

FOURIER TRANSFORM MASS SPECTROMETRY

DART MSI of drugs of abuse in hair

Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices

Learning Objectives. Overview of topics to be discussed 10/25/2013 HIGH RESOLUTION MASS SPECTROMETRY (HRMS) IN DISCOVERY PROTEOMICS

Quantification with Proteome Discoverer. Bernard Delanghe

Kazusa DNA Res Inst. Daisuke Shibata

Agilent Solutions for Lipidomics. Greater Insight into

Metabolomics: quantifying the phenotype

Polymer Additive Analysis by EI and APCI

Identification of Ginsenosides Using the SCIEX X500R QTOF System

Technical Note # TN-31 Redefining MALDI-TOF/TOF Performance

Introduction to Proteomics 1.0

Considerations of the use of Triple Quadrupoles or Ion Traps in Quantitative Applications

1 Seminario di Spettrometria di Massa. Università degli studi di Milano 23/06/2017 The world leader in serving science

METABOSCAPE A METABOLITE PROFILING PIPELINE DRIVEN BY AUTOMATIC COMPOUND IDENTIFICATION

AB Sciex QStar XL. AIMS Instrumentation & Sample Report Documentation. chemistry

High resolution mass spectrometry for bioanalysis at Janssen. Current experiences and future perspectives

MASS SPECTROMETRY IN METABOLOMICS

SYNAPT G2-S High Definition MS (HDMS) System

NIH Public Access Author Manuscript J Proteome Res. Author manuscript; available in PMC 2014 July 05.

Principles of Shotgun Lipidomics

Challenges in Separation Technologies

Christoph Zuth, Alexander L. Vogel, Sara Ockenfeld, Regina Huesmann and Thorsten Hoffmann * S-1. Supporting Information for:

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

An Alternative Approach: Top-Down Bioanalysis of Intact Large Molecules Can this be part of the future? Lecture 8, Page 27

Welcome! Mass Spectrometry meets Cheminformatics WCMC Metabolomics Course 2014 Tobias Kind. Course: Search of MS/MS files with the NIST MS Search GUI

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

Introduction to LC/MS/MS

Sample Concentration and Analysis of Human Hormones in Drinking Water

Essential Lipidomics Experiments using the LTQ Orbitrap Hybrid Mass Spectrometer

[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

Supplemental Information. LipiDex: An Integrated Software Package. for High-Confidence Lipid Identification

PTM Discovery Method for Automated Identification and Sequencing of Phosphopeptides Using the Q TRAP LC/MS/MS System

Supporting information

Transcription:

New Mass Spectrometry Tools to Transform Metabolomics and Lipidomics July.3.13 Ken Miller Vice President of Marketing, Life Sciences Mass Spectrometry 1 The world leader in serving science

Omics & the Central Dogma of Biology DNA Genomics 22, genes What could occur RNA Transcriptomics 1, transcripts What may occur Proteins Proteomics 1,, proteoforms What is occurring Metabolomics 2, compounds Lipidomics 1, species Metabolites Lipids What has occurred 2

Addressing the Metabolomics Challenges Developing SOPs for major sample types Innovating LC/MS to improve separation & detection Developing streamlined, workflow-oriented software Building and connecting to new and existing database 3

Orbitrap Delivers the Highest Quality Data Better data, Better results! Highest Resolution Best Mass Accuracy Widest Dynamic Range Excellent Sensitivity 4

LCMS Metabolomics Offerings Quan / Qual analysis of endogenous molecules of low molecular mass (<1-15Da) Profile Detect, align, and quantify components, use statistical analysis to find key features Thermo Scientific Dionex UltiMate 3 RSLC Thermo Scientific Exactive Series MS Identify Putative ID web or local DB search Confirm ID via MS 2 De novo structural ID via MS n Thermo Scientific Orbitrap Fusion MS Thermo Scientific Q Exactive MS Quantify Rountinely quantify sets of putative biomarkers in large sample populations TSQs High-End Budget Limited 5

Orbitrap Fusion Tribrid Mass Spectrometer Unmatched Analytical Performance Revolutionary performance Unprecedented usability Exceptional versatility Orbitrap Fusion 2 3 1 Tribrid: (trī-brǝd), n. three Mass Analyzers working in parallel to produce unmatched analytical results 6

Orbitrap Fusion Tribrid Mass Spectrometer Dual-pressure linear ion trap Ultra-high-field Orbitrap mass analyzer Ion-routing multipole Quadrupole mass filter Active beam guide (ABG) EASY-ETD (and IC) ion source 7

Flexible, Intuitive, Easy to Learn Software The Thermo Scientific Orbitrap Fusion Method Editor allows for drag and drop method building. Dynamic Scan Management for maximum data quality 8

Orbitrap Fusion Tribrid MS Unmatched Analytical Performance Scan rate FTMS 2 15 Hz Scan rate ITMS 2 Hz Max resolution 45K at Quad isolation down to.4 amu Ion trap isolation down to.2 amu Mass Accuracy 1 ppm Dissociation CID, HCD, ETD MSn Up to MS 1 in ion trap or Orbitrap Analyzers Q, FTMS, ITMS Detectors Ion Trap, Orbitrap Compact 1186 x 674 x 65 mm (w, d, h) 45, Resolution to remove spectral interferences CID/HCD/ETD detected by the Ion Trap or Orbitrap at any level of MS n for maximum experimental flexibility Powered by the new Dynamic Scan Management architecture that lets every user easily get the maximum information from every sample 9

Mass Accuracy Matters! Accurate mass improves the ability to confidently identify unknown compounds ppm error = (mass error / MW) x 1 6 EXAMPLE: Reserpine (C 33 H 4 N 2 O 9 ) has a protonated ion at 69.2866 Mass Error (ppm) # of Possible Chemical Formulae (using only C, H, N & O) 165 (.1 daltons) 9 1 13 5 7 3 4 2 2 1 2.5 (.3 daltons) 1 1

Orbitrap Fusion Tribrid Mass Spectrometer Challenge Generate absolutely most accurate data to facilitate compound identification. Orbitrap Fusion MS EASY IC (internal calibration): new ETD source allows use of internal calibration for sub-ppm mass accuracies. On/off toggle in SW. No ion suppression by IC. 11

Reagent/Internal Calibrant Source Tube lens is replaced with discharge ion source for IC & ETD 12

Internal Calibration: LC/MS of Omeprazole Metabolites 13

Internal Calibration: LC/MS of Omeprazole Metabolites H+ 1 O N N H S O N 362.1169 O = O R e l a t i v e I n t e n s i t y 1 2 3 4 5 6 7 8 9 Time (min) 14

Internal Calibration: LC/MS of Omeprazole Metabolites.28 ppm.55 ppm.47 ppm.55 ppm.55 ppm.47 ppm.35 ppm.55 ppm.36 ppm.28 ppm.47 ppm.55 ppm.28 ppm.3 ppm.2 ppm.19 ppm.19 ppm -.6 ppm.19 ppm.55 ppm.11 ppm.19 ppm -.14 ppm.19 ppm 3.7 3.8 3.9 4. 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 Time (min) 15

Internal Calibration: LC/MS of Omeprazole Metabolites.28 ppm -.5 ppm.11 ppm.55 ppm.47 ppm.55 ppm.55 ppm.47 ppm.11 ppm.35 ppm.3 ppm.28 ppm.55 ppm.36 ppm.47 ppm -.14 ppm.3.28 ppm ppm -.55 ppm -.22 ppm.28 ppm.3 ppm -.8 ppm.19 ppm.28 ppm.3 ppm.97 ppm.19 ppm -.6 ppm 3.7 3.75 3.8.11 ppm Time (min).55 ppm.47 ppm.2 ppm.19 ppm.55 ppm.19 ppm.19 ppm -.14 ppm.19 ppm 3.7 3.8 3.9 4. 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 Time (min) 16

Easy-IC Providing Sub-ppm Mass Accuracy in MS and MS/MS 1 9 8 7 6 5 4 3 1 1 9 8 7 6 5 4 3 1 Orbitrap Fusion MS operating @1K for FS, 15k for HCD MS2, with UHPLC. Sample, Urine. Analyte: L-Tryptophan, C 11 H 12 N 2 O 2, [M+H] + =5.9715 With IC Avg =.4 ppm 5.9717 5.9721 5.9721 5.9724 5.9723 5.9717 5.9717 5.9715 5.9718 5.97 Without IC Avg = 1.5 ppm 5.9741 MS 5.9747 5.9749 5.9746 5.974 5.977 5.9746 5.9772 5.9735 5.9738 2.76 2.77 2.78 2.79 2.8 2.81 2.82 2.83 2.84 2.85 2.86 Time (min) ASMS 13 poster MP45 by Junhua Wang et al. 1 9 8 7 6 1 9 8 7 6 5 4 3 1 With IC 1.4 ppm H 2N HCD MS/MS HN 118.653 HN 5.2 ppm HN O 4.8 ppm -.1 ppm OH 3 HN HN 132.89 N HN H 2 17.615 188.763 1 91.5422 8 1 1 14 16 18 Without IC 2.9 ppm 118.6544.4 ppm 1.7 ppm 1.9ppm 146.6.7 ppm 2. ppm 2.1 ppm 146.633 1.4 ppm 1.1 ppm 132.815 188.779 17.63 8 1 1 14 16 18 HO NH.9 ppm 1.8 ppm O 1.1 ppm 17

Orbitrap Fusion Tribrid Mass Spectrometer Challenge Separation of distinct isobars in complex mixtures Orbitrap Fusion MS Orbitrap Fusion can achieve up to 45, resolution. 18

See the Fine Isotope Pattern with Ultra-high Resolution L-Methionine C 5 H 11 NO 2 S PositiveMode1351892831 #656 RT: 2.64 AV: 1 NL: 1.48E8 T: FTMS + p ESI Full ms [1.-212.8] 15.584 R=6276 1 9 8 7 6 5 4 3 1.7ppm Positive Observed 151.618 R=62152 152.542 R=6182 15. 15.5 151. 151.5 152. 1 8 6 4 151.5 151.6 R=3k R=6k R=1k R=24k R=45k C5H11NO2S +H: C5 H12 N1 O2 S1 p(gss, s/p:4) Chrg 1... 1 9 8 7 6 5 4 3 1 15.583 R=499553.ppm Positive Simulated R=45, 151.617 R=499368 152.541 R=499443 15. 15.5 151. 151.5 152. C5H11NO2S +H: C5 H12 N1 O2 S1 p(gss, s/p:4) Chrg 1... 1 8 6 4 151.554 14 C 4 H 1 18 O 2 33 S 151.577 C 5 H 12 O 2 N 33 S 151.617 C 4 13 CH 12 O 2 NS 151.625 C 5 H 12 O 17 ONS 151.646 C 13 5 C 14 CH 18 9 O 17 O 151.5 151.55 151.6 151.65 ASMS 13 poster MP45 by Junhua Wang et al. 19

Resolving the Most Complex Sample Nano-infusion of NIST SRM195 plasma extract, Negative mode 8 6 4 1 167.213 R=35365 179.561 or 179.575? D-Glucose or Paraxanthine? 172.99141 R=49792 18.6662 R=56177 187.713 R=33315 215.3278 R=35614 3.49 21.84235 R=51372 R=53512 16 165 17 175 18 185 19 195 5 21 215 2 D-Glucose C6H12O6 Paraxanthine C7H8N4O2 1 9 8 7 6 5 4 3 1 1 9 8 7 6 5 4 3 1 179.5747 R=74 R=6, 179.55 179.6 179.5759 R=2875 R=24, 179.55 179.6 1 9 8 7 6 5 4 3 1 1 9 8 7 6 5 4 3 1 179.5763 R=14766 R=1, 179.55 179.6 179.5743 R=51682 R=45, D-Glucose 179.569 R=5377.55 ppm.55 ppm Paraxanthine 179.55 179.6 Confirmed with STD mixture. 1 9 8 7 6 5 4 3 1 9 8 7 6 5 4 3 1 R=6, 179.573 R=6766 1 9 8 7 6 5 4 3 1 179.558 R=13 179.574 R=1484 179.5 179.55 179.574 179.6 179.65 179.5 179.55 179.6 179.574 179.65 1 R=3464 1 R=6786 R=24,.56 ppm 179.56 R=275 1.1 ppm.55 ppm 9 8 7 6 5 4 3 1 R=1, 1.7 ppm R=45,.55 ppm 179.56 R=56282.55 ppm.55 ppm 179.5 179.55 179.6 179.65 179.5 179.55 179.6 179.65 ASMS 13 poster MP45 by Junhua Wang et al.

Orbitrap Fusion Tribrid Mass Spectrometer Challenge Achieve maximum coverage of the metabolome/lipidome. Many molecules require special fragmentation conditions to reveal their structural information. Orbitrap Fusion MS Instrument architecture allows for extremely fast MS/MS and full flexibility of MS n experiments for structural analysis including novel workflows such as HCD 3 and MS 2 HCD followed by MS 3 CID. 21

Method 1: The Super Q Exactive MS Mode MS in Orbitrap Data dependent HCD MS/MS in Orbitrap MS OT, R=7K Full MS.5s HCD MS 2 OT, R=17.5K MS 2 Top1 MS 2 Top2 RT: 1.6345-1.8627 SM: 5G 1 9 8 7 6 5 4 3 1 1 9 8 7 6 5 4 3 1 1.698 1.7699 1.7789 1.7879 1.7969 1.859 1.8149 1.716 1.6798 1.8241 1.7251 1.761 1.677 1.6525 1.75 1.8333 1.8516 1.7298 1.6572 1.6846 1.7118 1.741 1.6677 1.7657 1.7927 1.817 1.8393 1.64 1.66 1.68 1.7 1.72 1.74 1.76 1.78 1.8 1.82 1.84 1 Time (min) MS OT, R=6K Full MS MS 2 Top1 MS 2 Top2 MS 2 Top3 MS 2 Top4 MS 2 Top5 22

.5s RT: 2.5298-2.5478 1.4 1.2 1..8.6.4.2. 1.4 1.2 1..8.6.4.2 2.5384 2.5465 2.5315 2.535 2.5394 2.5432 2.5371 2.5445. 2.53 2.535 2.54 2.545 Time (min) NL: 1.68E8 Base Peak F: ms MS E3_FS6k_Uri ne_hcdit_su perit5ms NL: 3.44E6 Base Peak F: ms2 MS E3_FS6k_Uri ne_hcdit_su perit5ms MS Orbitrap, R=24K Full MS MS 2 Top1 MS 2 Top2 MS 2 Top3 MS 2 Top4 MS 2 Top5 23

Method 3: MS n Enables de novo Compound ID Standards Standards Infusion (or LC) Add HR/AM MS n Library Match Score Above Threshold IDs MS n technology Spectral library technology Algorithms for structuralspectral investigation Unknowns LC-MS n Tree Search Match Score Below Threshold Individual Spectrum Search Partial Structures Structure Candidates Sheldon, Mistrik, Croley, J Am Soc Mass Spectrom, 9, : 37-376 24

Method 3: HR/AM Ion Trees for Unknown Identification Full MS in Orbitrap Data dependent HCD MS 2 in ion trap Data dependent CID MS 3 in Orbitrap.5-.8s 1 1 1 MS 3.1791 3.1891 CID MS 3 OT.6 sec HCD MS 2 IT 3.178 3.18 3.182 3.184 3.186 3.188 3.19 Time (min) Full MS HCD/CID MS 2 in IT/OT MS 2 Top1 MS 2 Top2 HCD/CID MS 3 in IT/OT MS 2 Top1 MS 2 Top2 MS 2 Top3 MS 2 Top4 De novo structural elucidation: capture substructure with MS n ion tree 25

HCD MS n is Unique to Orbitrap Fusion MS OTMS> HCD OTMS 2 > HCD OTMS 3 HCD FTMS2 Scan Full FTMS Scan Orbitrap LPC HCD FTMS3 Scan HPC Ion Trap MP Q1 C-Trap Ion Routing Multipole Full Orbitrap MS scan Parent ion isolation in Q1 and HCD MS 2 > OTMS detection of MS 2 fragments HCD fragment isolation in the ion trap and HCD MS 3 Orbitrap MS detection of HCD MS 3 fragments 26

Structural Homology Identified by MS n Ion Tree Search 1 MS 3.1791 3.1891.6 sec NL: 3.38E6 Base Peak = 181.73-181.739 MS b667jwurine_hcdit_ci DOTtop2_5ms 1 1 1 8 6 4 3.178 3.18 3.182 3.184 3.186 3.188 3.19 Time (min) 1 8 6 4 CID MS 3 OT HCD MS 2 IT 69.1 6 8 1 1 14 16 18 CID MS 3 OT 69.447 95.8 96.556 15.1 6 8 1 1 HCD MS 2 IT O HN 124.2 N NH 1 8 6 4 141.91 69.1 isomers 95.773 15.77 NL: 1.59E5 Base Peak F: ms2 MS b667jwurine_hcdit_ci DOTtop2_5ms NL: 2.93E4 Base Peak F: ms3 MS b667jwurine_hcdit_ci DOTtop2_5ms 124.153 18.96 141.9145 18.9644 6 8 1 1 14 16 18 Theophylline MS 3 Library Match score 936.2 Query 1.8 ppm 1.9 ppm 27

The Industry s Leading Portfolio of MS Solutions Exactive Series MS Non-targeted Analysis HR/AM Tribrid Orbitrap MS Metabolomics Proteomics Bioanalysis Quantitative Food Safety Environmental Clinical/Toxicology Applied Markets Triple Quads Transform Your Science MS, MS n Research Markets Ion Traps Biomarker Discovery Proteomics Metabolism Qualitative Metabolomics PTM Analysis Lipidomics Targeted Analysis 28

29 Transform Your Science