ProSim 3 and 2 Vital Signs Simulators

Similar documents
ProSim 3 and 2. Vital Signs Simulators

ProSim 4 Vital Signs Simulator

MULTI-PARAMETER PATIENT SIMULATOR

BP Pump 2. Non-Invasive Blood Pressure Simulator and Tester. Technical Data. Key features

MPS450. Operators Manual. Multiparameter Simulator

medsim 300B Patient Simulator

Fundamentals of Pulse Oximetry

ProSim 8 Vital Signs Simulator

Rigel UNI-SiM Lite. The most cost-effective patient simulator on the market. Key Features n Compact and cost-effective

ProSim 8. Users Manual. Vital Signs Simulator

Rigel UNI-SiM. The world s smallest integrated NiBP, SpO2 and patient simulator. Key Features n Compact and cost-effective

Multiparameter Simulation

Vital Signs Simulator

ProSim 6/8. Users Manual. Vital Signs Simulator

medsim 300B Operators Manual Patient Simulator

Basic Dysrhythmia Interpretation

ProSim 4. Users Manual. Vital Signs Simulator

Rate: The atrial and ventricular rates are equal; heart rate is greater than 100 bpm (usually between bpm).

2017 BDKA Review. Regularity Rate P waves PRI QRS Interpretation. Regularity Rate P waves PRI QRS Interpretation 1/1/2017

Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing. D. J. McMahon cewood rev

Arrhythmia Study Guide 3 Junctional and Ventricular Rhythms

-RHYTHM PRACTICE- By Dr.moanes Msc.cardiology Assistant Lecturer of Cardiology Al Azhar University. OBHG Education Subcommittee

Automated Blood Pressure Monitor

AMPS-1. Advanced Modular Patient Simulator. Operating Manual

Testing the Accuracy of ECG Captured by Cronovo through Comparison of ECG Recording to a Standard 12-Lead ECG Recording Device

Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing

INSTRUCTION MANUAL. phantom 320 ECG Simulator 1.4

Patient Simulator. Instruction Manual. 04/2007, Peter Kron GmbH Subject to Technical Changes

CARESCAPE Patient Data Module

Cardiocap/5. GE Healthcare. The compact, all-in-one, critical care monitor. Features. Available options

Course Objectives. Proper Lead Placements. Review the ECG print paper. Review the mechanics of the Myocardium. Review basics of ECG Rhythms

The heart's "natural" pacemaker is called the sinoatrial (SA) node or sinus node.

UNDERSTANDING YOUR ECG: A REVIEW

Cardiac Rhythm Device Management. PBL STOP Your acronym for a standardized follow-up

Electrocardiography for Healthcare Professionals

Panorama. Arrhythmia Analysis Frequently Asked Questions

Invasive Measurement of Blood Pressure

EKG Abnormalities. Adapted from:

Biomedical Instrumentation

DEFIBRILLATORS. Prof. Yasser Mostafa Kadah

Figure 2. Normal ECG tracing. Table 1.

The HeartCheck TM PEN Handheld ECG Is your heartbeat slow, fast, or irregular? Are you at risk? Put your heart health in your own hands

CARESCAPE Patient Data Module

Electrocardiography Biomedical Engineering Kaj-Åge Henneberg

CORONARY ARTERIES. LAD Anterior wall of the left vent Lateral wall of left vent Anterior 2/3 of interventricluar septum R & L bundle branches

ABCs of ECGs. Shelby L. Durler

ECG MACHINE KEC- Series

Project Title Temporary Pacemaker Training Simulator

Cardiac Arrhythmias in Sleep

BEDSIDE ECG INTERPRETATION

GE Healthcare. The GE EK-Pro Arrhythmia Detection Algorithm for Patient Monitoring

Module 1: Introduction to ECG & Normal ECG

Infinity. Kappa XLT Patient Monitor. Because you care

Specified Tolerance (ms)

Model 5392 EPG Temporary Pacer

Sinus rhythm with premature atrial beats 2 and 6 (see Lead II).

Diploma in Electrocardiography

physiology 6 Mohammed Jaafer Turquoise team

COURSE DESCRIPTION. Rev 2.0 7/2013. Page 1 of 26

VitalSim Directions for Use

ISO INTERNATIONAL STANDARD. Implants for surgery Active implantable medical devices Part 2: Cardiac pacemakers

Diagnostic capabilities of the implantable therapeutic systems

COPYRIGHT Ramsey Medical, Inc.

Appendix D Output Code and Interpretation of Analysis

CATCH A WAVE.. INTRODUCTION NONINVASIVE HEMODYNAMIC MONITORING 4/12/2018

Outline. Electrical Activity of the Human Heart. What is the Heart? The Heart as a Pump. Anatomy of the Heart. The Hard Work

4/14/15 HTEC 91. Topics for Today. Guess That Rhythm. Premature Ventricular Contractions (PVCs) Ventricular Rhythms

EKG Rhythm Interpretation Exam

EHRA Accreditation Exam - Sample MCQs Cardiac Pacing and ICDs

ER75 Electro-Acoustic Ear Simulator. Operating Manual

91496-A B C I L. Summary

Emergency Medical Training Services Emergency Medical Technician Paramedic Program Outlines Outline Topic: WPW Revised: 11/2013

PACIFIC MEDICAL TRAINING Arrhythmia Interpretation

Welch Allyn HScribe Holter Analysis System

EKG Intermediate Tips, tricks, tools

Advanced ICD Concepts

EKG Competency for Agency

Electrocardiography for Healthcare Professionals

SURETEST Torque Calibration System

8/20/2012. Learning Outcomes (Cont d)


Please check your answers with correct statements in answer pages after the ECG cases.

Relax and Learn At the Farm 2012

CORONARY ARTERIES HEART

2) Heart Arrhythmias 2 - Dr. Abdullah Sharif

Mini Pulse Electronic Stimulator

MODEL EPG SINGLE CHAMBER TEMPORARY EXTERNAL PACEMAKER

DEFIB «U S E-HEART. CardioStart MEDICAL MEDIO TECHNOLOGIES BIPHASIC DEFIBRILLATORS К-ИЕЛКГ. Wmwie

The Portable Performance

GDT1000 SENSING ACUTE STUDY

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems

Assessing Arrhythmia Performance ST/AR Algorithm

Interactive Simulator for Evaluating the Detection Algorithms of Implantable Defibrillators

Study methodology for screening candidates to athletes risk

ECG ABNORMALITIES D R. T AM A R A AL Q U D AH

QUICK SETUP GUIDE SECULIFE DFBASE

Lab Activity 24 EKG. Portland Community College BI 232

Rhythm ECG Characteristics Example. Normal Sinus Rhythm (NSR)

Infinity MCable -Masimo SET

DEFIBRILLATORS ATRIAL AND VENTRICULAR FIBRILLATION

Transcription:

ProSim 3 and 2 Vital Signs Simulators Technical Data Don t need a comprehensive patient monitor tester? The 6-in-1 ProSim 3 and 4-in-1 ProSim 2 Vital Signs Simulators are clear choices for biomedical engineers and field service technicians that need a quality, feature-rich device with high portability. Choose one of these modern vital signs simulators for preventive maintenance, troubleshooting and repair. The ProSim 3 and 2 feature the perfect amount of features for testing in the field. We like to call it the Just Right feature set, and it includes: ECG pacemaker arrhythmia and performance testing respiration invasive blood pressure temperature cardiac output (ProSim 3 only) fetal/maternal (ProSim 3 only) Key features Portable, for evaluating the performance of patient monitors in the field 20 % lighter and 25 % smaller than preceding technology Just Right feature set includes: ECG, pacemaker, arrhythmia and performance testing, respiration, invasive blood pressure, temperature, cardiac output (ProSim 3 only), fetal/ maternal (ProSim 3 only) 43 high-quality waveforms With four IBP channels, ProSim 3 tests even the highest acuity scenarios Stay-connected ECG posts for secure lead connections Improved user interface and online Advantage Training demos Upgraded DIN connectors ensure consistency with the ProSim family; minimize cable compatibility issues Field upgradeable, and easily paired with other devices for comprehensive testing ProSim 3 and 2 are 510(k) cleared products

Specifications General specifications Temperature Operating 10 C to 40 C (50 F to +104 F) Humidity Altitude Dimensions (LxWxH) Display Communication Power Battery life Weight Storage -25 C to +50 C (-13 F to +122 F) 10 % to 80 % non-condensing 2,000 meters (6,562 ft) 14.0 cm x 20.6 cm x 4.5 cm (5.5 in x 8.2 in x 1.8 in) LCD greyscale display USB device upstream port Two 9 V alkaline batteries 8 hours continuous operation 0.47 kg (1 lb, 4 oz) Safety standards IEC 61010-1, Pollution degree 2 Certifications Electromagnetic compatibility (EMC) Detailed specifications Normal-sinus-rhythm waveform ECG Reference Normal sinus rhythm CE, CSA, C-TICK N 10140, RoHS IEC 61326-1; 2006 The ECG amplitudes specified are for Lead II (calibration), from the baseline to the peak of the R wave. All other leads are proportional. 12-lead configuration with independent outputs referenced to right leg (RL). Output to 10 universal ECG Jacks, color-coded to AHA and IEC Standards 0.05 mv to 0.45 mv (0.05 mv steps); 0.5 mv to 5.5 mv (0.5 mv steps) Amplitude Amplitude accuracy ± 2 % of setting Lead II. All other leads ± 5 % ECG rate 30, 40, 45, 60, 80, 90, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280 and 300 BPM Rate accuracy ± 1 % of setting ECG waveform selection Adult (80 ms) or pediatric (40 ms) QRS duration ST-segment elevation Adult mode only: -0.8 mv to +0.8 mv (0.1 mv steps) Additional steps: +0.05 mv and -0.05 mv 80 BPM, 1.0 mv, adult QRS, ST-segment elevation of 0 mv, and a P-R interval of 0.16 seconds Pacemaker waveform Pacer pulse Amplitude 0 (off), 1, 2, 5, 10 mv ± 10 % for lead II (reference lead) with other leads proportional as for performance waves. Accuracy Reference lead II: ± (5 % setting + 0.2 mv) Pacer pulse width 0.1, 0.5, 1.0, 1.5, 2.0 ms ±5% 2 Fluke Biomedical ProSim 3 and 2 Vital Signs Simulators

Paced arrhythmias Atrial 75 BPM Asynchronous 75 BPM Demand with frequent sinus beats Demand with occasional sinus beats Atrio-ventricular sequential Noncapture (one time) Nonfunction Off Arrhythmia Baseline NSR 80 BPM PVC focus Left focus, standard timing (except where specified) Supraventricular arrhythmia Atrial fibrillation (coarse or fine); atrial flutter sinus arrhythmia; missed beat (one time); atrial tachycardia; paroxysmal atrial tachycardia; nodal rhythm; and supraventricular tachycardia Premature arrhythmia (All one-time events) Premature atrial contraction (PAC); premature nodal contraction (PNC); PVC1 left ventricular; PVC1 left ventricular, early; PVC1 left ventricular, R on T; PVC2 right ventricularl PVC2 right ventricular, early; PVC2 right ventricular, R on T; and multifocal PVCs Ventricular arrhythmia PVCs 6, 12, or 24 per minute; frequent multifocal PVCs; bigeminy; trigeminy; multiple PVCs (one-time run of 2, 5, or 11 PVCs); ventricular tachycardia; ventricular fibrillation (coarse or fine); and asystole Conduction defect First-, second-, or third-degree AV block; and right- or left-bundlebranch block None (off) ECG performance testing Amplitude 0.05 to 0.45 mv (0.05 mv steps), 0.5 to 5.5 mv (0.5 mv steps) Pulse wave 30, 60 BPM, with 60 ms pulse width Square wave 2.0, 0.125 Hz Triangle wave 2.0, 2.5 Hz Sine wave 0.5, 5, 10, 40, 50, 60, 100 Hz R-wave detection waveform Haver-Triangle R-wave rate 30, 60, 80, 120, 200, and 250 BPM R-wave width 20 to 200 ms (10 ms steps) Additional Steps: 8, 10, and 12 ms Rate accuracy ± 1 % Amplitude accuracy ± 2 %, Lead II (Exception: ± 5 % for R waves 20 ms) None (off) Fetal/Maternal ECG (ProSim 3 only) Fetal heart rate (Fixed) 60, 90, 120, 140, 150, 210 and 240 BPM Fetal heart rate (IUP) 140 BPM at beginning, then varies with pressure Intrauterine-pressure waveforms Early deceleration, late deceleration, and uniform acceleration Wave duration 90 seconds, bell-shaped pressure curve, from 0 to 90 mmhg and returning to 0 IUP period 2, 3, or 5 minutes; and manual FHR 120 BPM, early deceleration, manual 3 Fluke Biomedical ProSim 3 and 2 Vital Signs Simulators

Invasive blood pressure Channels 4, each independently settable with identical parameters and are individually electronically isolated from other signals Input/output impedance 300 Ω ± 10 % Exciter input range 2.0 to 16.0 V rms Exciter-input frequency range DC to 5000 Hz Transducer sensitivity 5 or 40 μv/v/mmhg Pressure accuracy ± 2 % of setting + 2 mmhg (valid for dc excitation only) Static Levels, Channel 1-10, 0, 80, 160, 240, 320, 400 mmhg Static Levels, Channel 2-10, 0, 50, 100, 150, 200, 240 mmhg Static Levels, Channel 3-5, 0, 20, 40, 60, 80, 100 mmhg (ProSim 3 only) Static Levels, Channel 4-5, 0, 20, 40, 60, 80, 100 mmhg (ProSim 3 only) Dynamic waveforms, Channel 1 Arterial: 120/80, Radial Artery: 120/80, Left ventricle: 120/00, Right ventricle: 25/00 Dynamic waveforms, Channel 2 Arterial: 120/80, Radial artery: 120/80, Left ventricle: 120/00, Right atrium (central venous or CVP): 15/10, Right ventricle: 25/00, Pulmonary artery: 25/10, Pulmonary-artery wedge: 10/2, Left atrium: 14/4 Dynamic waveforms, Channel 3 Arterial: 120/80, Radial artery: 120/80, Left ventricle: 120/00, Right atrium (central venous or CVP): 15/10, Right ventricle: 25/00, Pulmonary artery: 25/10, Pulmonary-artery wedge: 10/2, Left atrium: 14/4 Dynamic waveforms, Channel 4 Swan-Ganz sequence, Right atrium (CVP), Right ventricle (RV), Pulmonary artery (PA), Pulmonary-artery wedge (PAW) Respiration artifact BP delta changes from 3 to 16 mmhg Output connector DIN 5-Pin 0 mmhg Respiration Rate 0 (OFF), 15, 20, 30, 40, 60, 80, 100, 120 BrPM Waves Normal or ventilated Ratio (inspiration: expiration) 1:1 Impedance variations (Δ Ω) 0.2, 0.5, 1 or 3 Ω peak-to-peak variation of lead impedance Accuracy delta ± 10 % Baseline 500, 1000, 1500, 2000 Ω, Leads I, II, III Accuracy baseline ± 5 % Respiration lead LA or LL Apnea selection OFF, 12, 22 or 32 seconds (one-time events), or continuous (Apnea ON = respiration OFF) 20 BrPM, delta 1.0 Ω, 1000 Ω baseline Temperature Temperature 0 C (32 F), 24 C (75.2 F), 37 F (98.6 C), and 40 C (104 F) Accuracy ± 1 C Compatibility Yellow Springs, Inc. (YSI) Series 400 and 700 4 Fluke Biomedical ProSim 3 and 2 Vital Signs Simulators

Output connector Circular DIN 4-pin 0 C (42 F) Cardiac output (ProSim 3 only) Catheter type Baxter Edwards, 93a-131-7f Calibration coefficient 0.542 (0 C) injectate), 0.595 (24 C injectate) Blood temperature 37 C (98.6 F) ± 2 % Injectate volume 10 cc Injectate temperature 0 C or 24 C ± 2 % value Cardiac output 2.5, 5, 10 liters per minute ± 5 % Faulty-injectate curve Waveform for simulation available Left-to-right shunt curve Waveform for simulation available Calibrated pulse 1.5 Output connector DIN 7-PIN 2.5 liters perminute, 0 C injectate 5 Fluke Biomedical ProSim 4 Vital Signs Simulator

Ordering information Models/descriptions ProSim 3 ProSim Vital Signs Simulator ProSim 2 ProSim Vital Signs Simulator Standard accessories ProSim 2/3 Instruction Sheet (multi-language) 4253822 ProSim 2/3 Users Manual CD 614487 Two 9-volt alkaline batteries (minimum 8 hours continuous use) 2392173 IBP Cable, unterminated 2392199 3010-0289FG, CI-3 Cable Assembly (Cardiac Output Box; ProSim 3 only) 1671807 USB cable 2248623 ProSim 2/3 Carrying Case AC power cords 4219453 AC/DC Power Supply 769422 AC Power Cord (Schuko) 284174 AC Power Cord (USA) 769455 AC Power Cord (UK) 658641 AC Power Cord (Australia) 2200218 AC Power Cord (Denmark) 2200229 AC Power Cord (India) 2200241 AC Power Cord (Israel) 2198785 AC Power Cord (Italy) 769448 AC Power Cord (Switzerland) Optional accessories 2523334 YSI 400 Series (UT-4) 2199019 YSI 700 Series (UT-2) 4022300 Cardiac output switch for GE About Fluke Biomedical Fluke Biomedical is the world s leading manufacturer of quality biomedical test and simulation products. In addition, Fluke Biomedical provides the latest medical imaging and oncology quality-assurance solutions for regulatory compliance. Highly credentialed and equipped with a NVLAP Lab Code 200566-0 accredited laboratory, Fluke Biomedical also offers the best in quality and customer service for all your equipment calibration needs. Today, biomedical personnel must meet the increasing regulatory pressures, higher quality standards, and rapid technological growth, while performing their work faster and more efficiently than ever. Fluke Biomedical provides a diverse range of software and hardware tools to meet today s challenges. Fluke Biomedical Regulatory Commitment As a medical test device manufacturer, we recognize and follow certain quality standards and certifications when developing our products. We are ISO 9001 and ISO 13485 medical device certified and our products are: CE Certified, where required NIST Traceable and Calibrated UL, CSA, ETL Certified, where required NRC Compliant, where required Fluke Biomedical. Better products. More choices. One company. Fluke Biomedical 6045 Cochran Road Cleveland, OH 44139-3303 U.S.A. Fluke Biomedical Europe Science Park Eindhoven 5110 5692EC Son, The Netherlands For more information, contact us: In the U.S.A. (800) 850-4608 or Fax (440) 349-2307 In Europe/M-East/Africa +31 40 267 5435 or Fax +31 40 267 5436 From other countries +1 (440) 248-9300 or Fax +1 (440) 349-2307 Email: sales@flukebiomedical.com Web access: www.flukebiomedical.com 2013 Fluke Biomedical. Specifications subject to change without notice. Printed in U.S.A. 3/2013 4263771B_EN Modification of this document is not permitted without written permission from Fluke Corporation. 6 Fluke Biomedical ProSim 3 and 2 Vital Signs Simulators