!"#$ Blood Pressure Monitor. Instruction manual page 1 Gebrauchsanweisung Seite 17 Gebruiksaanwijzing pagina 33

Similar documents
M1 Classic. Digital Blood Pressure Monitor. Instruction manual page 1 SYS. mmhg DIA. mmhg. PULSE/min

MX3 Plus English. Introduction. Table of contents. 1 How to obtain meaningful blood pressure readings

RX-3. Blood Pressure Monitor. Mode d emploi page 49 Manuale de instructone pagina 65 Manual de instrucciones pagina 81

Digital Blood Pressure Monitor

MANUAL BLOOD PRESSURE MONITOR BPM 168B Contents Blood Pressure Monitor Intended Use What is blood pressure?

E4 Tens Massager Low-Frequency Electronic Pulse Massager

AUTOMATIC WRIST Blood PReSSuRe MonIToR InSTRucTIon Manual

The Smart Blood Pressure Monitor. Instruction manual

Owner's Manual. Arm-type Fully Automatic Digital Blood Pressure Monitor. Arm Type. Model BSP-11

MD10826_Körperfettwaage_manual_UK.fm Seite 1 Mittwoch, 26. Juli :10 14

UPPER ARM AUTOMATIC BLOOD PRESSURE MONITOR. Model: Blood Pressure Monitor INSTRUCTION MANUAL

Blood Pressure Monitor

Digital Blood Pressure Monitor. Model UA-767 BT

Taking and recording blood pressure and pulse. City Gate Training Centre all rights reserved

Automatic Wrist Digital Blood Pressure Monitor Model Owner's Manual

Model UB-512. Wrist Digital Blood Pressure Monitor 使用手冊 翻譯. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

Model UB-511. Wrist Digital Blood Pressure Monitor 使用手冊 翻譯. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

BODY ANALYZER SCALE PS 8710

Important Warning/Medical Disclaimer... 1 Healthy Living... 2 Commonly Asked Questions... 4 Intended Use... 8 Measurement Method...

IB BP 3AS1-2 VarA5 0906

High Blood Pressure Blood Pressure Monitoring at Home -- F...

Contents. Helpline No. UK/ North Ireland Rep. Ireland Web Support Model Number: 12005

Blood Pressure Monitor User Manual

Data Collection Worksheet

PATIENT INFORMATION. Medicine To Treat: H ypertension. Patient Awareness and Self-Care

HOME BP USER INSTRUCTIONS

BP210 BP250. Automatic Blood Pressure Monitor. Medical Diagnostic Device

SLEEP IMPROVING WRISTBAND. Item No Owner s Guide

Model UA-767. Digital Blood Pressure Monitor 使用手冊翻譯. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

GlucCell TM SYSTEM USER S GUIDE Ver 2.1 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System

SMART BATHROOM SCALES

Owner s Manual. Deluxe Automatic Blood Pressure Monitor Upper Arm Model MODEL BP3400

Body Fat Scales. instruction manual. with body analysis functionality. Model Number BF801-BK SL/BL

Understanding Blood Pressure. A handy guide to understanding what blood pressure is, how it affects you, and how to measure it at home

Body Balance Shape F3

Home Blood Pressure Log

Dear HighQ Check System Owner :

science-u.org What affects blood Blood Pressure Directions You Will Need BEST FOR GRADES 5-8 ESTIMATED TIME Minutes

C200 bands are available in a variety of colors. Visit us at LifeTrakUSA.com

Hypertension Screening and Health Evangelism

Items in the package:

UNDERSTANDING BLOOD PRESSURE

Managing Blood Pressure: It Takes a Team

Nokia BPM. Blood Pressure - Heart rate Measurement. Installation and Operating Instructions EN - 1. Nokia BPM. v2.0 January 2018

Device Equivalence Evaluation Form

Digital Blood Pressure Monitor. Model UA-852

Device Equivalence Evaluation Form

Instruction Manual. Body Composition Monitor. Model HBF-358-BW. Thank you for purchasing OMRON Body Composition Monitor.

Managing your blood pressure

How To Measure Vital Signs

GlucCell TM SYSTEM USER S GUIDE ver 2.3 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System

AMERICAN ASSOCIATION OF SLEEP TECHNOLOGISTS TECHNICAL GUIDELINE FOR PATIENT ASSESSMENT AND VITAL SIGNS MEASUREMENT AND DOCUMENTATION

Device Equivalence Evaluation Form

Glass Body Fat Scale Instructions for use

Instruction Manual Body Fat Analyzer Scale

Medescan Nebuliser Med - S600A Instructions Manual

MERCURY SL. User Manual. MSL-180 (396lb x 0.2lb) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 1.1

EVER Pharma D-mine Pen Pen injector for Apomorphine 10 mg/ml

Importance Of Taking Manual Blood Pressure In Both Arms

OWNER S MANUAL. BODYCRAFT 7699 Green Meadows Dr., Lewis Center, Ohio Tel:

Device Equivalence Evaluation Form

Automatic Ar m Digital Blood Pr essur e Monitor. Owner ' s Manual. Ar m Type. M odel Safety Notice... 02

COPYRIGHT Ramsey Medical, Inc.

Section 03: Pre Exercise Evaluations and Risk Factor Assessment

BODY COMPOSITION SCALE

Ambulatory Services Orientation & Skill Review Skill Performance Checklist: Vital Signs. Name: Date:

BLOOD PRESSURE. Unit 3: Transportation and Respiration

Custom instruments. Insio primax User Guide. Hearing Systems

SARASOTA MEMORIAL HOSPITAL NURSING PROCEDURE. MEASURING BLOOD PRESSURE - MANUAL (equ04)

Contents Safety Instructions... 4 Package Contents... 6 Notes on Measurements... 7

Pain Relief Patch. Operation Manual Read Before Using MODEL # ET

Digital Wrist. Monitor. 6015N, 6016N Instruction Manual. Questions? Call ADC toll free at

Compressor Nebulizer System

WHOLE BODY VIBRATION THERAPY

Bands. Model : No For Customer Service, please contact:

Blood Pressure 1 of 22 Boardworks Ltd 2011

Function of Cell Membrane

Electric Mini Exercise Bike

TWIST STEPPER NO. 045

Body Fat Monitor / Scale Model: UM-040/041 Instruction Manual

Device Equivalence Evaluation Form

Model UA Digital Blood Pressure Monitor 使用手冊翻譯. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

Blood Glucose Monitoring System. User Guide

RC-S. Remote Control INSTRUCTIONS FOR USE

2. Measure a subject's blood pressure and heart rate both at rest and during exercise.

HUMAN ANATOMY AND PHYSIOLOGY

SMART TRAINER - HEART RATE MONITOR MODEL: SE139

StopSnoring. Advance. User Manual. Model LSS1

RENPHO Bluetooth Scale. Instruction Manual RP-520BT (LED)

For instance, it can harden the arteries, decreasing the flow of blood and oxygen to the heart. This reduced flow can cause

and bias, which are known to be present in self-home and in professional office BP measurements taken using the auscultatory technique [7].

Low Row. User manual E S S E N T I A L S T R E N G T H

Session 21: Heart Health

Welch Allyn ABPM 6100S. Comprehensive blood pressure monitoring that brings patient comfort home.

Arrhythmias. Pulmonary Artery

Healthy Blood Pressure Healthy Heart Beat. Initiated by the World Hypertension League

PROFESSIONAL CARE OXYJET air. powered. Downloaded from manuals search engine. filter. OxyJet

Wireless Blood Pressure Monitor

Connect with EatSmart

Transcription:

!"#$ Blood Pressure Monitor Instruction manual page 1 Gebrauchsanweisung Seite 17 Gebruiksaanwijzing pagina 33 Mode d emploi page 49 Manuale de instructone pagina 65 Manual de instrucciones pagina 81

Introduction The OMRON RX-3 measures your blood pressure and pulse simply and quickly from the wrist, without the use of an inflation bulb or stethoscope. The measurement values are stored in the memory of the OMRON RX-3. The OMRON RX-3 fits wrist circumferences from 13.5 to 19.5 cm. 1

How to obtain meaningful blood pressure readings General The OMRON RX-3 is not suitable for measuring the frequency of cardiac pacemakers. Consult your doctor during pregnancy, arrhythmia and arteriosclerosis. Avoid eating, drinking (alcohol), smoking, sport and taking a bath before measurement. Be calm and relaxed before and during measurement. You should never change the dose of medicines prescribed by your doctor. Caution Operating temperature between 10 C and 40 C. Operating environment must be free from excessive vibrations, shocks, magnetic fields, electrical noise, etc. Stay out of sunlight during measuring. Keep portable phones 5 meters away during measurement. Do not wrap the cuff other than around your wrist. Do not drop the OMRON RX-3. Tips for use Check your blood pressure at least twice a day (before breakfast, after work). Do not measure your blood pressure while you are in a vehicle. Always measure on the same wrist. Wrap the wrist cuff around your wrist before start of measurement. 2

Overview A C D B E A Display B Wrist Cuff C Memory Recall button D On/Off button E Battery Compartment 3

Preparation Insert batteries 1 Open the battery compartment. 2 Insert two batteries in the battery compartment. Caution! Use two identical 1.5V alkaline batteries type AAA LR03! 3 Close the battery compartment. 4

Fit wrist cuff Caution! Do not press On/Off button when the wrist cuff is not wrapped around the wrist! 1 Bare your wrist. Caution! Push up your sleeve: avoid constricting the blood flow! 2 Put the monitor on the inner side of your wrist. 3 Hold the end of the wrist cuff and wrap it around your wrist. Caution! Be sure the wrist cuff fits closely; do not pinch your arm! 5

Operation F J C D G K L M H P N 6 Control functions C Memory Recall button D On/Off button Measurement F Systolic blood pressure in mmhg. G Monitor blood pressure: flash - measurement takes place, light up - finish measurement. H Diastolic blood pressure in mmhg. J Memory display: values in memory. K Memory position: 1 to 28. L Inflation: wrist cuff inflates and measurement starts. M Deflation: wrist cuff deflates and measurement finishes. N Battery exhausted: batteries are weak/exhausted. P Pulse: heartbeats per minute.

RX-3 English Caution! Allow an interval of at least three minutes between two successive measurements! 1 Sit comfortably at a table with your feet flat on the floor and put your arm against the hard case. Caution! The OMRON RX-3 should always be at heart height during measurement. Usage of the hard case assures the right position of the OMRON RX-3! 2 Press On/Off button to start measurement. The OMRON RX-3 measures during inflation! Caution! Sit still, do not move, do not speak and do not touch the OMRON RX-3! 7

Read display 1 Read the values of blood pressure and pulse from the display. Note: Display shows alternately blood pressures and heartbeats. 8 2 Note values in your personal blood pressure pass. 3 Press On/Off button to turn off power.

Memory Recall previous values K Memory position of latest and previous values. K 1 Press Memory Recall button to turn on power. Note: Display shows alternately blood pressures and heartbeats. K 2 Press Memory Recall button for latest and previous values. Press On/Off button to turn off power. Note: Display shows alternately blood pressures and heartbeats. 9

Erase memory 1 Press Memory Recall button to turn on power. 2 Press Memory Recall button and simultaneously On/Off button to erase memory. Caution! All stored values will be erased! Press On/Off button to turn off power. 10

Storage Store the OMRON RX-3 in the hard case in a dry, closed place with a temperature between -20 C and 60 C. Remove the batteries if you not intend to use the OMRON RX-3 for 3 months or more. Faults: causes and rectifications Fault Cause Rectification Correct reading not possible Movement, sound vibration, Wait for at least three minutes to weak pulse repeat measurement Display Low voltage Batteries weak/exhausted Fit two new identical 1.5V alkaline empty batteries type AAA LR03 Inexplicable values Wrong working method Follow instructions, repeat measurement 11

Maintenance and spare parts Use a soft, slightly moistened cloth to clean the OMRON RX-3. Caution! Do not use petrol, thinners or similar solvents! Use a soft, moistened cloth and soap to clean the wrist cuff. Caution! Do not wash the wrist cuff! Caution! Do not use petrol, thinners or similar solvents! Do not carry out repairs of any kind yourself. If a defect occurs consult your OMRON retail outlet or distributor as mentioned on the packaging. Calibration It is recommended to have the OMRON RX-3 inspected every two years to ensure correct function and accuracy. Consult your OMRON retail outlet or OMRON distributor as mentioned on the packaging. Replace batteries Remove the battery out of the battery compartment and insert two new identical 1.5V alkaline batteries type AAA LR03 batteries. Spare parts Due to high company quality standards, OMRON considers the main unit as a non-serviceable part because the need for proper calibration after replacement of high tech components. If the cuff needs to be replaced have this done by an authorised expert. Consult your OMRON retailer or OMRON distributor as mentioned on the packaging. Attention! Disposal of batteries and the OMRON RX-3 should be carried out in accordance with the national regulations for the disposal of electronic products. 12

Technical Data Product name Model Display Measuring range Accuracy Inflation Deflation Pressure detection Measuring method Memory Power supply Battery life Operating temperature /humidity Operating environment Storage temperature / humidity Weight Outer dimensions Wrist circumference Accessories Note OMRON RX-3 wrist blood pressure monitor HEM-640-E Digital LCD Blood pressure: 0-299 mmhg / Pulse: 40-180 beats/minute Blood pressure: ± 3 mmhg / Pulse: ± 5% of display reading Automatic by electric pump Automatic rapid deflation system Pressure sensor (capacitive) Oscilliometric 28 Measurements 2 x 1.5V Alkaline batteries (LR03) AAA New batteries will last for approx. 300 measurements +10 C to +40 C / 30% to max. 85% relative humidity Free from excessive vibrations, shocks, magnetic fields, electrical noise, etc. -20 C to +60 C /10% to max. 95% relative humidity Approx. 140/160 g ex-/including batteries Approx. 47 mm (W) x 71 mm (H) x 79 mm (D) Approx. 13.5 cm to 19.5 cm Instruction manual, guarantee card, blood pressure pass, 2 alkaline batteries, storage box Subject to technical modification without prior notice = Type B 0197 Manufacturer EU-representative OMRON Matsusaka Co., Ltd. Japan OMRON Healthcare Europe B.V., Kruisweg 577, NL-2132 NA Hoofddorp This device fulfils the provisions of the EC directive 93/42/EEC (Medical Device Directive). This blood pressure monitor is designed according to the European standard EN1060, Non-invasive sphygmomanometers Part 1: General Requirements and Part 3: Supplementary requirements for electromechanical blood pressure measuring systems. 13

General information about blood pressure Blood circulation The blood circulation is responsible for supplying the body with oxygen. Blood pressure is the pressure exerted on the arteries. Systolic blood pressure (mmhg) The systolic blood pressure value (higher pressure or top value) represents the blood pressure produced by contraction of the heart muscle. The diastolic blood pressure value (lower pressure or lower value) represents the blood pressure produced by relaxation of the heart muscle. Classification of blood pressure The World Health Organisation (WHO) and the International Society of Hypertension (ISH) developed the blood pressure classification. This classification is based on the blood pressure values measured while sitting on a chair in the outpatient department of a hospital. 180 160 140 130 120 Normal systolic value Normal blood pressure Optimal blood pressure (target value) 80 Moderate hypertension Mild hypertension Severe hypertension 85 90 100 110 Diastolic blood pressure (mmhg) According to the blood pressure classification by the WHO/ISH. 14

Health and blood pressure The incidence of hypertension increases with age. In addition, a lack of exercise, excess body fat and high levels of cholesterol (LDL), which sticks to the inside in blood vessels, reduces elasticity of these vessels. Hypertension accelerates arterial sclerosis which can lead to very serious conditions such as stroke and myocardial infarction. For these reasons it is very important to know whether the blood pressure is within a healthy range. Blood pressure fluctuates from minute to minute, throughout the day. Therefore it is essential to take regular measurements to help you identify an average blood pressure. Symptoms of high blood pressure High blood pressure can go unnoticed for a long time, since it does not cause noticeable symptoms. The following are all possible causes of abnormally high blood pressure: Overweight High cholesterol level Smoking Excessive alcohol consumption Stress and emotional upset Excessive consumption of salt Lack of physical exercise Genetic/hereditary predisposition Underlying illnesses, such as kidney disorders or endocrine disturbance Blood pressure measurement Measuring your blood pressure daily enables you to recognize high blood pressure at an early stage and obtain medical treatment. The oscillometric method of measurement determines your blood pressure by measuring the pressure fluctuations caused by the pulse waves. Since your blood pressure fluctuates within a day (see graphic next page), you should always measure it at the same time each day to ensure that the measurements are genuinely comparable. At the doctor s surgery, nervousness and tension may cause your blood pressure to be higher than in familiar circumstances at home. This is known as White Coat Hypertension. 15

mmhg 200 150 100 50 Upper curve: systolic blood pressure Lower curve: diastolic blood pressure 6 12 18 24 Time of day Example: fluctuation within a day (male, 35 years old) Treatment of high blood pressure If your blood pressure reaches upper values of 140-160 mmhg and lower values of 90-95 mmhg in repeated measurements over several days, you should consult your doctor for detailed medical examination. You can assist the treatment prescribed by your doctor in the following ways: Loose weight and lower your cholesterol level by reducing the calories and fat in your diet. Cut down on animal fats and eat more fruit and vegetables. Reduce the consumption of alcohol. Reduce the intake of salt: the German League for Combating High Blood Pressure recommends six grams of salt per day (i.e. one teaspoon) on average. Stop smoking. Take regular exercise. Monitor your blood pressure. 16