4D PET: promises and limitations

Similar documents
Pitfalls and Remedies in PET/CT imaging for RT planning

Image Guided Stereotactic Radiotherapy of the Lung

Clinical PET/CT imaging. PET/CT - Optimization of torso imaging. CT-based attenuation correction. PET/CT torso imaging

Which Planning CT Should be Used for Lung SBRT? Ping Xia, Ph.D. Head of Medical Physics in Radiation Oncology Cleveland Clinic

Typical PET Image. Elevated uptake of FDG (related to metabolism) Lung cancer example: But where exactly is it located?

GE Healthcare. Rad Rx. White Paper

Motion gating and tracking techniques: overview and recent developments

Cardiac CT - Coronary Calcium Basics Workshop II (Basic)

FDG-18 PET/CT - radiation dose and dose-reduction strategy

PET-CT for radiotherapy planning in lung cancer: current recommendations and future directions

Average CT in PET studies of colorectal cancer patients with metastasis in the liver and esophageal cancer patients

Identifying Image Artifacts, Their Causes and How to Fix Them: PET. Brad J Kemp, PhD Mayo Clinic, Rochester, MN

Optimized PET/CT protocols: how much CT is needed? Increasing use of PET-CT. Imaging in Lymphoma

Preview of Presentation

Introduction Pediatric malignancies Changing trends & Radiation burden Radiation exposure from PET/CT Image gently PET & CT modification - PET/CT

CARDIAC PET PERFUSION IMAGING with RUBIDIUM-82

4D-MRI for Radiotherapy of moving Tumours: Latest developments, comparison to 4D-CT. J. Biederer Vancouver, August 2, 2011

Radiation treatment planning in lung cancer

Stereotaxy. Outlines. Establishing SBRT Program: Physics & Dosimetry. SBRT - Simulation. Body Localizer. Sim. Sim. Sim. Stereotaxy?

Patterns and Prevalence of Misregistration in 18 F-FDG PET/CT

Photon Attenuation Correction in Misregistered Cardiac PET/CT

Combined Anatomical and Functional Imaging with Revolution * CT

Measurement of Respiratory and Cardiac Motion Using a Multi Antenna Continuous Wave Radar Operating in the Near Field

First Clinical Experience with

Image Registration for Radiation Therapy Applications: Part 2: In-room Volumetric Imaging

PET/CT for Therapy Assessment in Oncology

Low Dose Era in Cardiac CT

In-Room Radiographic Imaging for Localization

Managing Radiation Risk in Pediatric CT Imaging

SBRT I: Overview of Simulation, Planning, and Delivery

In-Room Radiographic Imaging for Localization

Breast Cancer PET/CT Imaging Protocol

Integrated PET/CT systems State of the art and Clinical Applications

PET-MRI in Cardiac Imaging: Initial Experience

Why is CT Dose of Interest?

Uncertainties and Quality Assurance of Localization and Treatment in Lung SBRT Jing Cai, PhD Duke University Medical Center

Relation of external surface to internal tumor motion studied with cine CT

Fellows on this rotation are expected to attend nuclear conferences and multimodality imaging conference.

An audit of radiation dose of 4D CT in a radiotherapy department

Use of molecular and functional imaging for treatment planning The Good, The Bad and The Ugly

The Effects of DIBH on Liver Dose during Right-Breast Treatments Introduction

8/10/2016. PET/CT for Tumor Response. Staging and restaging Early treatment response evaluation Guiding biopsy

Credentialing for the Use of IGRT in Clinical Trials

Ultralow Dose Chest CT with MBIR

Raja Muthupillai, PhD. Department of Diagnostic and Interventional Radiology St. Luke s Episcopal Hospital. Research Support: Philips Healthcare

Pitfalls in SBRT Treatment Planning for a Moving Target

The development of combined PET/CT scanners has

Deformation Effect on SUV max Changes in Thoracic Tumors Using 4-D PET/CT Scan

Ryan Niederkohr, M.D. Slides are not to be reproduced without permission of author

The High-End Solution for Real-Time Patient Tracking

Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement

Implementing SBRT Protocols: A NRG CIRO Perspective. Ying Xiao, Ph.D. What is NRG Oncology?

Quantitative Molecular Imaging Using PET/CT to Assess Response to Therapy

Douglas J. Simpkin, Ph.D. Aurora St. Luke s Medical Center Milwaukee, Wisconsin. www.

RTTs role in lung SABR

8/2/2012. Transitioning from 3D IMRT to 4D IMRT and the Role of Image Guidance. Part II: Thoracic. Peter Balter, Ph.D.

Inter-fractional Positioning Study for Breast Cancer with Proton Therapy using a 3D Surface Imaging System

Case-Based Pitfalls of SPECT and PET: Recognizing and Working with Artifacts

Toshiba Aquillion 64 CT Scanner. Phantom Center Periphery Center Periphery Center Periphery

Imaging Rotation. University of Michigan Department of Radiation Oncology Division of Radiation Physics. Resident:

A comparison of radiation doses from modern multi-slice Computed Tomography angiography and conventional diagnostic Angiography:

4D Radiotherapy in early ca Lung. Prof. Manoj Gupta Dept of Radiotherapy & oncology I.G.Medical College Shimla

肺癌放射治療新進展 Recent Advance in Radiation Oncology in Lung Cancer 許峰銘成佳憲國立台灣大學醫學院附設醫院腫瘤醫學部

Cardiac Imaging Tests

Subject: Image-Guided Radiation Therapy

45 Hr PET Registry Review Course

The Effects of DIBH on Liver Dose during Right-Breast Treatments: A Case Study Abstract: Introduction: Case Description: Conclusion: Introduction

The role of PET with 18 F-FDG has largely been demonstrated in clinical oncology, especially lung cancer (1). In

Management of respiratory motion for lung radiotherapy: a review

FAZA-PET Imaging for Tumour Hypoxia

A Snapshot on Nuclear Cardiac Imaging

Doses from pediatric CT examinations in Norway Are pediatric scan protocols developed and in daily use?

Radiation induced DNA double strand breaks undergoing PET/CT examinations.

Shozo Yamashita Kunihiko Yokoyama Masahisa Onoguchi Haruki Yamamoto Shigeaki Hiko Akihiro Horita Kenichi Nakajima

X-Ray & CT Physics / Clinical CT

RAMPS-GNYCHPS 2010 Spring Symposium New York, NY, April 30, Error Prevention and Patient Safety for Radiation Treatment and Diagnosis

Respiratory gated PET/CT in a European multicentre retrospective study: added diagnostic value in detection and characterization of lung lesions

Low-dose and High-resolution Cardiac Imaging with Revolution CT

Impact of scanning parameters and breathing patterns on image quality and accuracy of tumor motion reconstruction in 4D CBCT: a phantom study

The Role of Nuclear Imaging in Heart Failure

Ct angiography, icd-10

8/10/2016. PET/CT Radiomics for Tumor. Anatomic Tumor Response Assessment in CT or MRI. Metabolic Tumor Response Assessment in FDG-PET

Advances in MRI for Radiation Therapy

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

Learning Objectives. New Developments in Radiation Therapy Targeting. Respiration-Induced Motion. Targeting Uncertainty in RT

NEW 3.0. Manufactured by

Accurate attenuation correction (AC) is a major clinical

Clinical evaluation of respiration-induced attenuation uncertainties in pulmonary 3D PET/CT

Disclosure. Imaging for Treatment Planning. Acknowledgements. Industry Grant Funding: Physics Advisory Board: IMPAC

Varian Edge Experience. Jinkoo Kim, Ph.D Henry Ford Health System

Image Fusion, Contouring, and Margins in SRS

Treatment Efficiency and Optimization of Patient Care with IBA ProteusOne

Fulfilling the Promise

Managing the imaging dose during image-guided radiation therapy

IGRT Solution for the Living Patient and the Dynamic Treatment Problem

IAEA RTC. PET/CT and Planning of Radiation Therapy 20/08/2014. Sarajevo (Bosnia & Hercegovina) Tuesday, June :40-12:20 a.

CT Optimisation for Paediatric SPECT/CT Examinations. Sarah Bell

PET/MR:Techniques, Indications and Applications

Transcription:

4D PET: promises and limitations Tinsu Pan, Ph.D. M.D. Anderson Cancer Center The University of Texas Background Outlines Gating techniques: Deep inspiration breath hold 4D PET/CT Non-gating techniques Average CT (0.87 msv) to match the temporal resolution of PET Summary PET/CT applications at M.D.Anderson Nuclear Medicine Radiation Oncology

Utilization of 4D-CT and 4D-PET 1 PET before treatment Longer setup time (5 min) Longer acq. time (10 min) Longer proc. time (10 min) Patient comfort Effectiveness? 4D PET/CT (challenging to perform in the clinic) 4D PET Trigger 1 2 3 4 5 Trigger 8 1 7 6 2 3 4 5 6 7 8 time Bin 1 Bin 8 Longer acquisition time Generates complete image-set for each respiratory phase

CT Scanner Cine CT images 4D-CT RPM Monitoring system Respiratory Trace Computer Sorting Pan, et al, Med Phys 04 4D PET/CT patient study 4D PET patient study SUV=5.0 SUV=8.5

4D PET/CT of the heart Which one is not a limitation of a 4D PET scan (relative to a regular PET scan)? 20% 1. Longer acquisition time 10% 10% 3% 13% 2. Higher radiation exposure from F18-FDG 3. More complex in set-up 4. No reimbursement for 4D PET 5. More complex in post-processing Which one of the following is not a limitation of a 4D PET scan compared with a regular PET scan? 1. Longer acquisition time 2. Higher radiation exposure from F18-FDG 3. More complex in set-up and post-processing 4. No reimbursement for 4D PET 5. Need 4D CT for accurate quantitation Ref: Nehmeh, SA, et al, Four-dimensional (4D) PET/CT imaging of the thorax. Med Phys 2004

Which CT data should be used for attenuation correction of the 4D PET data? 17% 1. End-inspiration CT 17% 2. End-expiration CT 3% 3. Free-breathing CT 13% 4. 4D CT 13% 5. Average CT Which CT data should be used for attenuation correction of the 4D PET data? 1. End-inspiration CT 2. End-expiration CT 3. Free-breathing CT 4. 4D CT 5. Average CT Ref: Nehmeh, SA, et al, Four-dimensional (4D) PET/CT imaging of the thorax. Med Phys 2004 Nuc Med (Osman, JNM 05) Clinical impact Rad Onc (Liu IJORBP 06) # Patients 300 152 (57% III & VI) Rad Onc (Aristophanous, IJORBP 11) Nuc Med (Chi IJORBP 08) 10 216 259 Cardiology (Gould JNM 07) Study PET/CT 4D-CT 4D-PET PET/CT w/act Misalignment Motion 2% 11% > 1cm All < 1 cm 15% SUV > 20% Cardiac PET/CT w/act 40% % Volume significant 8% 100% (17) Centroid shift 6% 5 mm (13) No evidence that 4D PET improves planning

Quantification of PET data Attenuation correction No AC AC Quantitation of PET needs CT data Activity concentration and SUV Activity Concentration SUV (g/ml)= SUV Measured activity ( k Bq / ml) Injected dose( k Bq ) Body weight ( g ) 1 mci = 3.7 x 10 7 dps = 3.7 x 10 7 bequerel (Bq) Differences between PET and CT PET CT 0.5 sec rotation scan of 15 cm for 2 to 5 mins, spatial resolution ~ 5-10 mm temporal resolution ~ breathing cycle scan of 90 cm < 20 sec spatial resolution < 1 mm temporal resolution < 1 sec Potential misalignment between PET and CT images

Free-breathing or breath-hold CT? Helical CT data acquisition X-ray tube PET det. CT det. PET det. Breathing Artifacts Protocol: 16x0.625 mm, 0.8 s gantry rotation, pitch 1.375:1 Speed: 13.75 mm/0.8 s or 17.2 mm/s

Breathing artifacts to physiological info Breath cycle= 80.3/(13.75/0.8)= 4.67 s Heart rate= (21/(13.75/0.8)) -1 *60= 49 bpm Misalignment in breathing states Scout Helical CT X-ray on End-inspiration (FB) Mid-expiration (BH) End-expiration (FB) 0 20 40 60 80 100 120 (sec) Pan et al, JNM, 2005 Mis-matched PET-CT data sets Mismatch 1: CT diaphragm position lower than PET Mismatch 2: CT diaphragm position higher than PET

RPM Average CT (ACT) Data acquired at high temporal resolution and averaged over one breath cycle Attenuation correction, RT dose calculation, IGRT CT Scanner Cine CT images 4D-CT Tracking system Respiratory Trace Computer Sorting Pan, et al, JNM 05 MIP(mip) Average Cine CT Data Acquisition X-ray tube PET det. CT det. PET det. Average CT 5 mgy (0.87 msv per 14 cm)

Average CT and slow CT 0.5 sec rotation 4 sec rotation Average CT (4 sec) Slow CT (4 sec) Average CT is better than slow CT (2 adjacent CT slices of 2.5 mm apart) 4-s slow CT 4-s slow CT Average CT Average CT Pan, et al, Med Phys 06 PET/CT protocol with ACT Acquire helical CT PET det X-ray tube PET det CT det

PET/CT protocol with ACT Acquire helical CT Acquire PET PET det X-ray tube 7-9 beds 2-5 min/bed PET det CT det PET/CT protocol with ACT Acquire helical CT Acquire PET PET det X-ray tube PET det CT det Misalignment between PET and CT data? PET/CT protocol with ACT Acquire helical CT Acquire PET Acquire cine CT cine duration ~ 5 s PET det X-ray tube PET det CT det

Combined CT ACT Helical CT w ACT Helical CT w/o thorax Helical CT Pan, et al, Med Phys 06 Clinical Data Clinical Studies NSCLC +57% Esophageal +56%

Lung or liver lesion? Lung lesion or liver lesion? Average CT Colorectal cancer

Colorectal cancer Average CT Inside the liver? Outside the liver Average CT

Tumor and cardiac imaging HCT PET HCT ACT PET ACT SUV=2.6 SUV=5.0 Improve the restaging after chemo PET/CT scan indicated a positive response to induction chemo with HCT. The patient had a negative response to the chemo with ACT. Pan, et al, Med Phys 08 Impact on treatment planning Previous GTV was outlined based on CT and clinical PET without motion correction. New GTV was redefined based on the correct information from PET with ACT. Old GTV New GTV Pan, et al, Med Phys 08

Total time (min) per procedure Quantitation, Registration + RTP Quantitation Quantitation Quantitation RTP Registration 1. 20 min WB PET/CT + 5 min patient setup time 2. Patient comfort threshold is about 30 min maximum with arms up 3. ACT: Average CT 4. DIBH: Deep inspiration BH 5. RTP: Radiation Therapy Planning 6. Gated PET: end expiration phase PET Summary Respiratory gating PET can improve quantification, yet is challenging to implement in the clinic Respiratory gated or 4D-CT is routine in RT Average CT can improve registration of CT and PET 193 SBRT lesions (37<1 cm<112<2 cm<44<3 cm)

193 SBRT lesions (37<1cm, 112<2cm and 44<3cm) Some factors other than respiratory motion affecting quantification Incorrect patient info 168 kg, 133 cm, SUV = 4.8, BMI = 95

Correct patient info 133 kg, 168 cm, SUV = 3.8, BMI = 47 Patient head motion Motion corrected Patient motion during the scan

X-ray on off Cine CT images Helical CT 1st table position (0-2cm) Helical CT without thorax 2nd table position (2-4 cm) Combined helical and respiration-averaged CT Respiration-averaged CT 3rd table position (4-6 cm) Image averaging Correction of patient motion Cine acquisition for average CT (120 kv, 8 X 2.5 mm, 10 ma, 5 s duration) 5 mgy PET/CT with ACT PET/CT Console CT Console Cine CT images ACT Computer Pan, et al, Med Phys 07

Which one is not correct for average CT? 10% 1. It has a temporal resolution of about one breath cycle 10% 10% 10% 3% 2. It can be used for dose calculation in RT 3. It can be used in registration with CBCT in IGRT 4. It can be derived from 4DCT 5. It has a well-defined boundary for a moving object Which one of the following is not correct for average CT? 1. It has a temporal resolution of one breath cycle 2. It can be used for dose calculation 3. It can be used in registration with CBCT for IGRT 4. It can be derived from 4DCT 5. It has a well-defined boundary for the diaphragm Ref: Pan T, et al, Attenuation correction of PET images with respiration-averaged CT in PET/CT. JNM, 2005. 46(9): p.1481-7 Cardiac imaging No AC

Cardiac imaging No AC Average CT Oncology PET/CT dose estimate Injection dose: 10 mci per patient 1 mci = 3.7 x 10 7 dps = 3.7 x 10 7 bequerel (Bq) Radiation dose: 7 msv from PET 5 to 10 msv from CT < 0.5 to 1 msv from ACT Radiation dose: 3.6 msv from the environment The standardized update value measured in PET is not dependent on 37% 1. Patient height 20% 13% 17% 13% 2. Patient weight 3. Injected activity (Bq) 4. Measured activity concentration (kbq/ml) 5. Calibration of the PET system

The standardized update value measured in PET is not dependent on 1. Patient height 2. Patient weight 3. Injected activity (Bq) 4. Measured activity concentration (kbq/ml) 5. Calibration of the PET system Ref: Huang, SC, Anatomy of SUV. Standardized uptake value. Nucl Med Biol, 2000. 27(7): p.643-6