Find the fittest MACS ART Annexin V System

Similar documents
MACSxpress Technology Untouched cell isolation directly from blood products

Efficient T cell activation and expansion. T Cell TransAct

Cardiovascular research solutions. Conveniently groundbreaking

MACS Cell Pre-Enrichment for flow sorting and analysis

Clinical research Treg cell manufacture CliniMACS Cell Separation System and MACS GMP Products

The broadest portfolio for your innate lymphoid cell research

CliniMACS Technology in stem cell transplantation

Changing the way of generating engineered T cells. CliniMACS Prodigy T Cell Transduction Process

Regulatory T cell research

The broadest portfolio for your T cell research

Myocardial regeneration autologous stem cell therapy

All you need for your T cell research

Isn t it worth two bags?

IFN-γ Secretion Assay Detection Kit (PE) human

MACS Marker Screen. MACS Marker Screen. Catalog antibodies. antibodies CD4 (VIT4) CD11b. MACS Marker Screen antibodies. Catalog. antibodies CD2 CD14

PRODUCT INFORMATION. New Reagents for Dako CoverStainer. Choose the H&E staining intensity you want.

Direct ex vivo characterization of human antigen-specific CD154 + CD4 + T cells Rapid antigen-reactive T cell enrichment (Rapid ARTE)

In vitro human regulatory T cell expansion

In vitro human regulatory T cell expansion

Bio-Rad Laboratories HEMOGLOBIN Testing Bio-Rad A1c. VARIANT II TURBO Link System. Fully-Automated HbA 1c Testing

Dako IT S ABOUT TIME. Interpretation Guide. Agilent Pathology Solutions. ALK, ROS1 and RET IQFISH probes (Dako Omnis) MET IQFISH probe (Dako Omnis)

Hand Hygiene in Focus. MICROSHIELD Product Catalogue

ETB Data. there was. compared

The first and only fully-automated, multiplexed solution for Measles, Mumps, Rubella and Varicella-zoster virus antibody testing

ab65311 Cytochrome c Releasing Apoptosis Assay Kit

Results you can trust

508 the number of suicide deaths in deaths per 100,000 people was the suicide rate in Suicide deaths in 2013 by gender

artus EBV QS-RGQ Kit Performance Characteristics May 2012 Sample & Assay Technologies Analytical sensitivity plasma

Mitochondria/Cytosol Fractionation Kit

VARIAN ONCOLOGY. RapidArc. One revolution is all it takes.

For personal use only

Chemical compatibility of the Pall QPoint TM Docking Station - Tap Assembly with common surface disinfectants

Bio-Rad Laboratories HEMOGLOBIN Testing Bio-Rad A1c. VARIANT II TURBO Link. Fully-Automated HbA 1c Testing

Arrow-Clark VectorFlow Hemodialysis Catheter Because in Chronic Hemodialysis Catheters, the Tip Matters

BioPlex 2200 Infectious Disease Panels

WESTERN EUROPE PREVALENCE AND INCIDENCE OF PERIPHERAL ARTERY DISEASE AND CRITICAL LIMB ISCHEMIA 2017

Pala Mix & Match DS Artificial teeth for CAD/CAM process

NobelProcera Implant Bar Overdenture complete range of fixed and removable solutions.

Bio-Rad Laboratories. Hemoglobin Testing. VARIANT II Hemoglobin Testing System For HbA 1c

Immunohematology. IH-QC Modular System. Select. Combine. Control.

Sperm donation Oocyte donation. Hong Kong þ Guideline þ þ Hungary þ þ þ þ Israel þ þ þ þ Italy þ þ þ. Germany þ þ þ þ Greece þ þ þ þ

Infectious Disease Testing. ULTRA Product Line. Safety is not a Matter of Chance

PyroMark Q24 CpG MGMT Handbook

HER2 CISH pharmdx TM Kit Interpretation Guide Breast Cancer

Tamer Mahmoud Said, M.D

Cardiac Assessment Controls

Application of μmacs Streptavidin MicroBeads for the analysis of HIV-1 directly from patient plasma

BEFLEX CUSTOMER SURVEY 2016

Rapid- Vitrification System. Closed system for simple and successful vitrification.

In vitro human regulatory T cell suppression assay


Men & Health Work. Difference can make a difference Steve Boorman & Ian Banks RSPH Academy 2013

Continuous peripheral nerve block catheter

Summary of Results for Laypersons

Optimize your success

SPERM PREPARATION, HANDLING & STORAGE

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Content: About Seaforia. Introduction Seaforia Sperm Seaparation System Seaforia procedure Seaforia Disposable Kit Seaforia Lab Kit.

FOR YOUR PRECIOUS MOMENTS IN LIFE

Core-Shell Technology for Proteins and Peptides

Radiotherapy and Radiosurgery

Seaforia Sperm Separation System. Product Catalog

Improving Food Process Control Using the

WCPT COUNTRY PROFILE December 2017 HUNGARY

HRM Series PCB Power Relays

Terms and Conditions. VISA Global Customer Assistance Services

University of Groningen. Selection of non-apoptotic, DNA intact spermatozoa Mahmoud, Tamer Mahmoud Said

ACCESS + NAVIGATION + STABILIZATION

SS3 Series. Controlled Avalanche Power Diodes. Features: Mechanical Data: SMC/DO-214AB. Page 1 28/03/06 V1.0

MENTAL HEALTH CARE. OECD HCQI Expert meeting 17 th of May, Rie Fujisawa

Thermo Scientific ART Pipette Tips

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

Global Trade in Lightweight Coated Writing Paper TradeData International Pty Ltd ( Page 1 5/18/2015

FUNCTIONAL TRAINING SOLUTIONS

Annexin V-FITC Apoptosis Detection Kit

ISO INTERNATIONAL STANDARD. Non-destructive testing Penetrant testing Part 1: General principles

DIFFERENT NEEDS...YOUR GLOBAL SOLUTION. Specification Guide. Hip Knee Spine Navigation

D7.1 Report summarising results of survey of EU countries to identify volumes and trends in relation to the import and export of stem cells

D7.1 Report summarising results of survey of EU countries to identify volumes and trends in relation to the import and export of stem cells

micromanipulation by vitrolife A complete solution for ICSI procedures.

The first convertible endotracheal tube

In-Use Evaluation Report

Type 1 Diabetes Australian Research Impact Analysis

Third Party Controls for Your Dade Behring Systems

Endo Fascial Closure System

Maxwell Technologies, Inc. Global Headquarters 3888 Calle Fortunada San Diego, CA USA Phone: +1 (858) Fax: +1 (858)

Tamer M. Said Mahmoud, M.D., Ph.D. BIOBLIOGRAPHY

Navigate Complex Interventions at Every Turn

The OECD Health Care Quality Indicators Project

arrow nextstep antegrade & Arrow Edge The next step in dialysis catheter technology

Understanding eggs, sperm and embryos. Marta Jansa Perez Wolfson Fertility Centre

Sirtex Medical Limited (ASX:SRX)

Recommended composition of influenza virus vaccines for use in the 2007 influenza season

Bio-Rad Laboratories. Cardiac Assessment Controls. Value Assigned for Clinical Laboratory and Point of Care Test Systems

PE Annexin V Apoptosis Detection Kit User Manual KT40001

Thermo Scientific Finntip Pipette Tips. HANDHELD PIPETTING Finntip Pipette Tips. Details

Transcription:

Find the fittest MACS ART Annexin V System

Easy, fast, and specific depletion of unwanted apoptotic spermatozoa Improve quality of sperm preparations Obtain desired population within 30 minutes Proven technology for optimal results

Researchers have reported that purified sperm populations show higher overall quality in terms of: Morphology¹ Sperm Deformity Index¹ Motility²,³ DNA fragmentation Mitochondria membrane potential integrity³,⁴,⁵ Apoptosis Cryosurvival rates²,⁴ Improve the quality of spermatozoa preparations Be specific, be successful The presence of apoptotic cells in sperm preparations for assisted reproduction is known to decrease specimen quality. Unfortunately, commonly used techniques for preparing sperm may not remove apoptotic spermatozoa with the required specificity. That s why the MACS ART Annexin V System was designed to selectively remove apoptotic spermatozoa from sperm preparations. Even early apoptotic spermatozoa with an intact cellular membrane are efficiently depleted, to yield spermatozoa fractions for use in subsequent operations in Assisted Reproductive Technology (ART). Select only the highest quality for your next sperm preparation. Scientist obtained a sperm population with: Improved sperm fertilization potential (sperm capacitation index, hamster oocyte penetration assay)⁶,12 Improved Induced Acrosome Reaction Test (IART)⁷,⁸ Increased sperm chromatin decondensation⁹,11 Improved cleavage rates after fertilization¹⁰ References 1 Aziz, N. et al. (2007) Human Reproduction 22: 1413 1419. 2 Said, T. et al. (2005) Fertility and Sterility 83: 1442 1446. 3 De Vantéry Arrighi, C. et al. (2009) Reproductive Biology Endocrinology 7: 1. 4 Grunewald, S. et al. (2006) Cell and Tissue Banking 7: 99 104. 5 Paasch, U. et al. (2005) Asian Journal of Andrology 7: 61 69. 6 Said, T. et al. (2006) Biology of Reproduction 74: 530 537. 7 Lee, T. et al. (2010) Human Reproduction 25: 839 846. 8 Grunewald, S. et al. (2006) Ann. N. Y. Acad. Sci. 1090: 138 146. 9 Grunewald, S. et al. (2009) Fertility and Sterility 92: 572 577. 10 Dirican, E. K. et al. (2008) Journal of Assisted Reproduction and Genetics 25: 375 381. 11 Delbes, G. et al. (2013) Journal of Andrology 1: 689 706. 12 Sheikhi, A. et al. (2013) Journal of Andrology 1: 845 849.

Specific depletion of apoptotic spermatozoa The MACS ART Annexin V System is intended for in vitro depletion of apoptotic human spermatozoa. The system selectively depletes unwanted cells using the ability of Annexin V to recognize the antigen EPS (externalized phosphatidylserine) in the plasma membrane of apoptotic cells. Phosphatidylserine-positive cells are depleted from fresh, cryopreserved, or otherwise manipulated semen samples. The yielded spermatozoa fraction is suitable for use in Assisted Reproductive Technology. How it works Apoptotic cell depletion begins with magnetic labeling of apoptotic cells by the MACS ART Annexin V Reagent. The labeled cells are then passed through a separation column located in a magnetic field. Unwanted cells are selectively retained in the column. Living spermatozoa are not labeled by the reagent, so they pass through the column and are collected for later use. Labeling Magnetic labeling of PS-exposing spermatozoa with MACS ART Annexin V Reagent Separation Magnetically labeled spermatozoa are retained within a MACS Column. Viable spermatozoa are collected in the flow-through. Cellular membrane Extracellular Intracellular Living Apoptotic MACS ART Annexin V Reagent Phosphatidylserine (PS) Phosphatidylserine (PS) Unlabeled viable spermatozoa Magnetically labeled, PS-exposing spermazota Figure 1: Translocation of PS from the intracellular to the extracellular surface of the plasma membrane during apoptosis. Figure 2: Isolation of PS-exposing cells using the MACS ART Annexin V System.

MACS ART Annexin V System Depletion of apoptotic spermatozoa with the MACS ART Annexin V System is simple and fast. It adapts easily into laboratories to enhance classical sperm parameters and lower sperm apoptotic markers. Additionally, it can be combined with other sperm preparation techniques for procedural flexibility. Components of the MACS ART Annexin V System include the MACS ART Annexin V Reagent, MACS ART Binding Buffer, and MACS ART MS Column. All are free of human and animal-derived components. Product specifications, such as endotoxin content or sterility, are confirmed by batch-specific certificates of analysis to ensure consistency of quality. The system has been tested in a Mouse Embryo Assay (MEA), which is widely used to assess the toxicity of materials used in human assisted reproduction and to detect embryo-toxic materials. The MACS ART Annexin V System shows no embryo toxicity. Determination of sperm number Centrifugation Resuspension of cell pellet Magnetic labeling Separation ART Figure 3: The depletion of apoptotic spermatozoa with the MACS ART Annexin V System is simple and fast. Product Content Order no. MACS ART Annexin V Reagent 1 0.1 ml reagent 200-070-502 MACS ART Annexin V Reagent 6 0.1 ml reagent 200-070-503 MACS ART Binding Buffer 6 10 ml buffer 200-070-505 MACS ART MS Column 6 columns 200-070-500 MACS ART Separation Unit 1 unit 200-070-501 MACS MultiStand 1 piece 130-042-303 MACS ART Annexin V Complete Kit 6 0.1 ml reagent, 6 10 ml buffer, 6 columns 200-070-507

Germany/Austria/ Switzerland Miltenyi Biotec GmbH Friedrich-Ebert-Straße 68 51429 Bergisch Gladbach Germany Phone +49 2204 8306-0 Fax +49 2204 85197 macs@miltenyibiotec.de USA/Canada Miltenyi Biotec Inc. 2303 Lindbergh Street Auburn, CA 95602, USA Phone 800 FOR MACS Phone +1 530 888 8871 Fax +1 530 888 8925 macs@miltenyibiotec.com Australia Miltenyi Biotec Australia Pty. Ltd. Unit 16 A, 2 Eden Park Drive Macquarie Park NSW 2113 Australia Phone +61 2 8877 7400 Fax +61 2 9889 5044 macs@miltenyibiotec.com.au Benelux Miltenyi Biotec B.V. Schipholweg 68 H 2316 XE Leiden The Netherlands macs@miltenyibiotec.nl Customer service The Netherlands Phone 0800 4020120 Fax 0800 4020100 Customer service Belgium Phone 0800 94016 Fax 0800 99626 Customer service Luxembourg Phone 800 24971 Fax 800 24984 China Miltenyi Biotec Technology & Trading (Shanghai) Co., Ltd. Room 2309 No. 319, Xianxia Road Changning District 200051 Shanghai, P.R. China Phone +86 21 62351005 Fax +86 21 62350953 macs@miltenyibiotec.com.cn France Miltenyi Biotec SAS 10 rue Mercoeur 75011 Paris, France Phone +33 1 56 98 16 16 Fax +33 1 56 98 16 17 macs@miltenyibiotec.fr Italy Miltenyi Biotec S.r.l. Via Persicetana, 2/D 40012 Calderara di Reno (BO) Italy Phone +39 051 6 460 411 Fax +39 051 6 460 499 macs@miltenyibiotec.it Japan Miltenyi Biotec K.K. Nittsu-Eitai Building 5F 16-10 Fuyuki, Koto-ku, Tokyo 135-0041, Japan Phone +81 3 5646 8910 Fax +81 3 5646 8911 macs@miltenyibiotec.jp Nordics and Baltics Miltenyi Biotec Norden AB Scheelevägen 17 223 70 Lund Sweden macs@miltenyibiotec.se Customer service Sweden Phone 0200-111 800 Fax 046-280 72 99 Customer service Denmark Phone 80 20 30 10 Fax +46 46 280 72 99 Customer service Norway, Finland, Iceland, and Baltic countries Phone +46 46 280 72 80 Fax +46 46 280 72 99 Singapore Miltenyi Biotec Asia Pacific Pte Ltd. 100 Beach Road #28-06 to 28-08 Shaw Tower Singapore 189702 Phone +65 6238 8183 Fax +65 6238 0302 macs@miltenyibiotec.com.sg South Korea Miltenyi Biotec Korea Petra building 659 Yeoksam-dong Gangnam-gu Seoul, South Korea Phone +82 2 555 1988 Fax +82 2 555 8890 macs@miltenyibiotec.co.kr Spain Miltenyi Biotec S.L. C/Luis Buñuel 2 Ciudad de la Imagen 28223 Pozuelo de Alarcón (Madrid) Spain Phone +34 91 512 12 90 Fax +34 91 512 12 91 macs@miltenyibiotec.es United Kingdom Miltenyi Biotec Ltd. Almac House, Church Lane Bisley, Surrey GU24 9DR, UK Phone +44 1483 799 800 Fax +44 1483 799 811 macs@miltenyibiotec.co.uk www.miltenyibiotec.com Miltenyi Biotec provides products and services worldwide. Visit www.miltenyibiotec.com/local to find your nearest Miltenyi Biotec contact. This print material is not for use in the USA. The MACS ART Annexin V System is manufactured by Miltenyi Biotec GmbH and tested under an ISO 13485 certified quality system. These products are available in Europe as CE-marked medical devices. For availability in your country, please contact your local sales representative. MACS is a registered trademark of Miltenyi Biotec GmbH. Copyright 2014 Miltenyi Biotec GmbH. All rights reserved 130-104-569