Industry-Tested. Stacks Up To the Competition 2

Similar documents
Active Fixation Models: 7740, 7741 and 7742 Passive Fixation Models: 7731, 7732, 7735 and 7736

ImageReady MR-Conditional Model List

Accessing Battery Information. Status symbol. Figure 1. Summary Dialog screen. Figure 2. Battery Status screen of a TELIGEN ICD 1

A Closer Look. X-ray Identification in Boston Scientific Pulse Generators SUMMARY. X-ray Identifier. Figure 1. X-ray identifier

Advanced ICD Concepts

Check for the presence of blood or body fluids on the lead terminal/electrode tip and in header ports. Clean as necessary with sterile water.

A Closer Look. LATITUDE TM NXT Alerts SUMMARY. Alerts. Red Alerts

D044, D045, D046, D047, D174, D175, D176, D177 D020, D021, D022, D023 D150, D151, D152, D153 D010, D011, D012, D013 D140, D141, D142, D143

Q & A: How to Safely Scan Patients with a SureScan MRI Pacemaker

A Closer Look. Connecting DF-4 and IS-4 Leads to DF-4 and IS-4 Defibrillators

MEDTRONIC CARELINK NETWORK FOR PACEMAKERS. Comparison between the Medtronic CareLink Network for Pacemakers and Transtelephonic Monitoring

Programming Manual for MRI Protection Mode

Size (mm) (H W D) Mass (g) Volume (cc)

Diagnostic Value of the ICD Atrial Lead in Accurate Discrimination of Supraventricular from Ventricular Arrhythmias The ALTITUDE EGM Study

A Closer Look. LATITUDE NXT Alerts SUMMARY. Alerts. Red Alerts

CARDIAC DEVICE MR-CONDITIONAL PRODUCT SUMMARY CHART

SJM MRI ACTIVATOR HANDHELD DEVICE WORKFLOW Model: EX4000. SJM-EDTR Item approved for U.S. use only.

COGNIS. Specifications. COGNIS: Model N119 ZIP TELEMETRY CARDIAC RESYNCHRONIZATION THERAPY

Call Medtronic at 1 (800) to verify the patient s current implanted system

IMAGEREADY MR CONDITIONAL PACING SYSTEM

Model 5392 EPG Temporary Pacer

PHYSICIAN S TECHNICAL MANUAL

Product Performance Report. Implantable devices. Pacing leads. Pacemakers. Defibrillators SNIA GROUP

ACCOLADE , ACCOLADE MRI, PROPONENT , PROPONENT MRI, ESSENTIO , ESSENTIO MRI, ALTRUA FORMIO , FORMIO MRI, VITALIO , VITALIO MRI, INGENIO , INGENIO

Essentials of Pacemakers and ICD s. Rajesh Banker, MD, MPH

Version überholt. Nicht verwenden. Version obsolète. Ne pas utiliser. Versione obsoleta. Non utilizzare. Verouderde versie. Niet gebruiken.

Review of Pacemakers and ICD Therapy: Overview and Patient Management

Azure XT DR MRI SureScan W2DR01

EXAMPLE PROTOCOL FOR PATIENT SCANNING PROCESS

PACEMAKER INTERPRETATION AND DEVICE MANAGEMENT PART I

Solara CRT-P MRI SureScan W1TR06

Puzzling Pacemakers Cheryl Herrmann, APN, CCRN, CCNS-CSC-CMC

ENGINEERED TO ENABLE THE FUTURE OF CONNECTED HEALTH

INGEVITY MRI. rsion überholt. Nicht verwenden. Version obsolète. Ne pas utiliser. ated version. Do not use.

MEET MICRA. Micra TM ACTUAL SIZE. Transcatheter Pacing System

Pediatric pacemakers & ICDs:

MRI SURESCAN SYSTEMS. Patient Scanning Process PATIENT PRESCREENING. SureScan Pacing, Defibrillation, and CRT-D Systems Verification

PERIOPERATIVE MANAGEMENT: CARDIAC PACEMAKERS AND DEFIBRILLATORS

PACING AT THE BUNDLE OF HIS

Percepta CRT-P MRI SureScan W1TR01

Managing Metallic Artifacts in MRI

NEED A DEFIBRILLATOR? NOW YOU HAVE OPTIONS.

MEET MICRA. Micra TM ACTUAL SIZE. Transcatheter Pacing System

MRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System

Azure S DR MRI SureScan W3DR01

ALTRUA 50 and ALTRUA 60

CRM Product Guide. Pacing, Defibrillation, and Cardiac Resynchronization Therapy. December Dielines do not print

ΤΟ ΗΚΓ ΣΤΟΝ ΒΗΜΑΤΟΔΟΤΟΥΜΕΝΟ ΑΣΘΕΝΗ

MODEL EPG SINGLE CHAMBER TEMPORARY EXTERNAL PACEMAKER

EHRA Accreditation Exam - Sample MCQs Cardiac Pacing and ICDs

Advisa MRI and Ensura MRI SureScan pacing systems

Programming of Bradycardic Parameters. C. W. Israel, M.D. Dept. of Cardiology Evangelical Hospital Bielefeld Germany

Physician s Manual FLEXTEND. Steroid-Eluting Extendable/Retractable Helix Pace/Sense Leads MODELS: 4086/4087/4088

Micra MC1VR01. MRI procedural information for Micra Model MC1VR01 MR Conditional single chamber transcatheter pacing device (VVIR)

CONSULTA CRT-P Model C4TR01

Version überholt. Nicht verwenden. Version obsolète. Ne pas utiliser. Versione obsoleta. Non utilizzare. Verouderde versie. Niet gebruiken.

PACING SYSTEMS.

INTERPRETING THE ECG IN PATIENTS WITH PACEMAKERS

FRONTIER II. User s Manual. Model 5586 Model Biventricular Cardiac Resynchronization Device with AF Suppression Algorithm

Clinical Data Summary: Avoid FFS Study

Figure 2. Normal ECG tracing. Table 1.

Dual Chamber Temporary External Pacemaker

Implant Procedure Concepts

ENABLE MRI CLINICAL STUDY SUMMARY

Pocket Adaptor Kit FOR SPINAL CORD STIMULATION. Tip Cards

TIP CARD. Model Temporary External Pacemaker

National Coverage Determination (NCD) for Cardiac Pacemakers (20.8)

PHYSICIAN S TECHNICAL MANUAL INGENIO

Supplemental Material

Temporary pacemaker 삼성서울병원 심장혈관센터심장검사실 박정왜 RN, CCDS

Verity ADx XL DR Model 5356* SR Model 5156* Pulse Generators *with AutoCapture Pacing System. User s Manual

STANDARD OPERATING PROCEDURE (SOP)

PERMANENT PACEMAKERS AND IMPLANTABLE DEFIBRILLATORS Considerations for intensivists

FREQUENTLY ASKED QUESTIONS MONITORING

PATIENT WITH ARRHYTHMIA IN DENTIST S OFFICE. Małgorzata Kurpesa, MD., PhD. Chair&Department of Cardiology

ICD Diagnostics: Making the most of it

A Closer Look Product Education at a glance

LATITUDE Patient Management System

RELIANCE 4 FRONT PHYSICIAN S LEAD MANUAL

FINELINE II STEROX EZ Models 4469/4470/4471/4472/4473/4474 Guidant Implantable Pacing Lead

Pacing Codes and Modes Concepts

Automatic Identification of Implantable Cardioverter-Defibrillator Lead Problems Using Intracardiac Electrograms

Intermittent episodes of paced tachycardia: what is the cause?

Subcutaneous implantable cardioverter defibrillator insertion for preventing sudden cardiac death

Cardiac Rhythm Device Management. PBL STOP Your acronym for a standardized follow-up

ICD: Basics, Programming and Trouble-shooting

PHYSICIAN S LEAD MANUAL FINELINE II STEROX EZ. Implantable Lead 4469/4470/4471/4472/4473/4474

MRI SureScan pacemakers & ICDs what you need to know

Ass. Prof. Tomon Thongsri, MD Buddhachinaraj Phitsanuloke Hospital

12 th International Winter Arrhythmia School Collingwood, Ontario February 7, Dr. Derek Yung. MD, FRCPC

Pacing Lead Implant Testing. Document Identifier

NORTH OF ENGLAND CARDIOVASCULAR NETWORK (NECVN)

Evia. Family of Implantable Pulse Generators. Technical Manual

MICRA TRANSCATHETER PACING SYSTEM (TPS) REIMBURSEMENT OVERVIEW

PHYSICIAN S LEAD MANUAL. ENDOTAK RELIANCE G Dual Shock Coils with GORE Coating. ENDOTAK RELIANCE SG Single Shock Coil with GORE Coating

EnTrust D154VRC Single Chamber ICD 35J delivered 8 seconds BOL, 11.8 seconds ERI 10.7 years**** 35cc, 68g Programmable Active Can

MR Conditional FINELINE II STEROX.book Page 1 Tuesday, March 3, :41 PM PHYSICIAN S LEAD MANUAL FINELINE II STEROX.

The heart's "natural" pacemaker is called the sinoatrial (SA) node or sinus node.

Solia S. Bipolar, steroid-eluting endocardial lead with extendable and retractable screw. Technical Manual 0123 (2010) 90/385/EEC

2009 CPT Codes for Cardiac Device Monitoring

Transcription:

With READY TM

Industry-Tested Stacks Up To the Competition 2 INGEVITY TM MRI Pacing Lead, the industry s leading-edge pacing technology, 1 is also the most extensively studied. 2 % of leads 10% 9% 8% 7% 6% 5% 4% 3% 2% Lead-Related Complication % 5 Safety, performance, and effectiveness of the INGEVITY MRI Pacing Lead are backed by the industry s largest pacing study Comprised of 2 studies, INGEVITY and SAMURAI, with over 150 sites worldwide 3 Over 2,300 implant procedures completed 3 In the industry s largest clinical studies for pacing leads, INGEVITY TM demonstrated: Very low rates of complications at 2.1% 3 A dislodgment complication rate of 1.2% (26/2264) 3 No adverse events when performing MRI and no change in electrical performance 3 In the SAMURAI trial, no MR-related complications were observed 4 Data Source 1% 0% Lead-Related Comp % Sample Size Manufacturer Data Type** Year INGEVITY MRI (Active + Passive Leads) INGEVITY + SAMURAI* INGEVITY Trial SAMURAI Trial Advisa Trial* 5086 MRI * MRI Lead Studied, ** MC = Multi-center, P = Prospective REVO Trial* CapsureFix Tendril Novus 5076 1488T 2.3% 2.0% 3.2% 3.0% 3.7% 2.4% 2.7% 2.1% 4.8% 2264 1599 665 526 928 238 220 140 353 BSC BSC BSC MDT MDT MDT STJ BSC MDT MC, P MC, P MC, P MC, P MC, P MC, P MC, P MC, P MC, P 2015 2015 2015 2013 2011 2000 2001 2000 2005 5076 Trial 1488 T Trial Flextend Flextend Trial Select Secure 3830 3830 Trial

Peer-Approved 99.3% In the INGEVITY TM and SAMURAI studies combined, 99.3% of physicians surveyed were satisfied with overall handling performance of INGEVITY MRI Pacing Lead 4,6 Thoughtfully engineered to ease delivery and improve maneuverability during implant. In the studies: Small, thin 6F lead body design for improved handling 99.7% of physicians surveyed rated handling and maneuverability as met or exceeded their expectations 4,6 99.4% of physicians surveyed agree or somewhat agree that INGEVITY MRI Pacing Lead was easy to pass through small vessels 4,6 97.1% of physicians surveyed rated radiopacity as met or exceeded expectations 4,6 Isodiametric lead body design provides a smooth, non-transition body feel from tip to terminal to ease access to fixation site Discover more INGEVITY TM benefits at www.bostonscientific.com/ingevity

ImageReady MR-Conditional Pacing Systems INGEVITY MRI leads are approved for use with the ACCOLADE MRI and ESSENTIO MRI pacemakers as an ImageReady MR-Conditional Pacing System 7 Safe and effective for full body scanning in 1.5T and 3T MRI environments when MRI Conditions of Use are met 7 First Level Controlled Operating Mode (SAR 4W/Kg) for all INGEVITY MRI lead models 7 Broad portfolio with 7 active and passive fixation MRI pacing lead models approved in combination with SR, DR, and EL ACCOLADE MRI and ESSENTIO MRI pacemaker models Assured Performance Beyond MRI ImageReady MR-Conditional Pacing Systems offer: Automatic Daily Monitoring LATITUDE NXT Patient Management System allows for earlier intervention and improved patient outcomes Post-Operative System Test (POST) Eases patient discharge with an automatic system evaluation that improves workflow after implant Actionable Data 8 Provides a comprehensive view of your patients AT/AF and HF status so that you can intervene earlier and more efficiently monitor their disease progression* Respiration-Based Pacing System Only Boston Scientific offers respiration-based pacing therapy to help fully restore Chronotropic Competence 9 * Data provided by the ACCOLADE System is intended to support screening and management of AT/AF but does not diagnose AF. For more information, visit www.bostonscientific.com/imageready, or call 1.844.427.2674 (1.844.4BSC.MRI) LATITUDE NXT Patient Management System from Boston Scientific CRM Intended Use The LATITUDE NXT Patient Management System is intended for use to remotely communicate with acompatible pulse generator from Boston Scientific CRM and transfer data to a central database. The LATITUDE NXT System provides patient data that can be used as part of the clinical evaluation of the patient. Contraindications The LATITUDE NXT Patient Management System is contraindicated for use with any implanted device other than a compatible Boston Scientific implanted device. Not all Boston Scientific implanted devices are compatible with the LATITUDE NXT System. For contraindications for use related to the implanted device, refer to the System Guide for the Boston Scientific implanted device being interrogated. Precautions Alerts may appear on the LATITUDE NXT website on a daily basis. Primary notification of alert conditions is through the View Patient List page on the LATITUDE NXT website. The clinician needs to log onto the LATITUDE NXT website in order to receive alerts. Although secondary notification through email and SMS text messages is available, these reminders are dependent on external systems and may be delayed or not occur. The secondary notification feature does not eliminate or reduce the need to check the website. Implanted device data and alerts are typically available for review on the LATITUDE NXT website within 15 minutes of a successful interrogation. However, data uploads may take significantly longer (up to 14 days). If the Communicator is unable to interrogate the implanted device or if the Communicator is unable to contact the LATITUDE NXT server to upload data, up to two weeks may elapse before the LATITUDE NXT server detects these conditions and informs the clinic user that monitoring is not occurring. If both of these conditions occur at the same time, this notification could take up to 28 days. Implanted device data and alert notification may be delayed or not occur at all under various conditions, which include but are not limited to the following: System limitations; the Communicator is unplugged; the Communicator is not able to connect to the LATITUDE NXT server through the configured phone system; the implanted device and the Communicator cannot establish and complete a telemetry session; the Communicator is damaged or malfunctions; the patient is not compliant with prescribed use or is not using the LATITUDE NXT System as described in the patient manual; if subscribed to the LATITUDE Cellular Data Plan, missing two or more payments discontinues the subscription; the clinic user can identify any patients that are not being monitored as described above by using the Not Monitored filter on the View Patient List. Adverse Effects: None known. System Limitations The LATITUDE NXT System does not provide continuous real-time monitoring. As a remote monitoring system, the LATITUDE NXT System provides periodic patient monitoring based on clinician configured settings. There are many internal and external factors that can hinder, delay, or prevent acquisition and delivery of implanted device, sensor, and patient information as intended by the clinician. These factors include: implanted device clock; patient environment; cellular data service; telephone system; communicator memory capacity; clinic environment; schedule/configuration changes; or data processing. Refer to the product labeling for specific instructions for use. Rx only. (Rev. C)

Pacing Leads from Boston Scientific INGEVITY MRI Extendable/Retractable Fixation and Tined Fixation INDICATIONS INGEVITY MRI Leads are intended for chronic pacing and sensing in the right atrium (only preformed atrial J with the Tined Fixation) and/or right ventricle (only straight with the tined fixation) when used with a compatible pulse generator. CONTRAINDICATIONS Use of these leads are contraindicated in: patients with a hypersensitivity to a nominal single dose dexamethasone acetate: 0.61 mg for Tined Fixation, 0.91 mg for Extendable Retractable Fixation; and patients with mechanical tricuspid heart valves. WARNINGS Refer to the product labeling before implanting the lead to avoid damage to the pulse generator and/or lead. For single patient use only. Do not reuse, reprocess, or resterilize. Always have external defibrillation equipment available during implant and electrophysiologic testing. Ensure that an external defibrillator and medical personnel skilled in CPR are present during post-implant device testing should the patient require external rescue. Lead fracture, dislodgment, abrasion, or an incomplete connection can cause a periodic or continual loss of pacing or sensing or both. Although pliable, the lead is not designed to tolerate excessive flexing, bending, or tension. Do not kink, twist, or braid the lead with other leads. Implant of the system cannot be performed in an MRI site Zone III (and higher). Take care to obtain appropriate electrode position. Failure to do so may result in suboptimal lead measurements. Unless all of the MRI Conditions of Use (as described in the MRI Technical Guide) are met, MRI scanning of the patient does not meet MR Conditional requirements of the implanted system. Refer to the MRI Technical Guide for potential adverse events applicable when Conditions of Use are met or not met, as well as a complete list of MRI-related Warnings and Precautions. Do not subject a patient with an implanted pulse generator and/or lead to diathermy. For Extendable/Retractable Fixation: The safety and efficacy of the tip electrode placement in the right ventricle above midseptum has not been clinically established. PRECAUTIONS Refer to the implant product labeling for cautions specific to clinical considerations, sterilization and storage, handling, implantation, hospital and medical environments, and follow up testing of the lead. Failure to observe these cautions could result in incorrect lead implantation, lead damage/dislodgment, or harm to the patient. Prior to implantation of this lead, confirm lead/pulse generator compatibility. Lead fracture, dislodgment, abrasion, or an incomplete connection can cause a periodic or continual loss of pacing or sensing or both. Defibrillation equipment should be kept nearby during the implant procedure. Optimum threshold performance might not be achieved if the lead is chronically repositioned because the steroid can be depleted. For Extendable/Retractable Fixation: Avoid creating sharp bends while extending or retracting the helix. Sharp bends can increase the risk of breaking the conductor coil or fixation mechanism during helix extension or retraction. Do not rotate the terminal pin clockwise or counterclockwise more than the recommended maximum number of turns indicated in the specifications. Continuing to rotate the terminal pin once the helix is fully extended or retracted (as indicated by fluoroscopy) can damage the lead, cause a conductor coil break during fixation, cause lead dislodgment, tissue trauma, and/or cause acute pacing threshold to rise. POTENTIAL ADVERSE EVENTS Potential adverse events include, but are not limited to the following: allergic/ physical/physiologic reaction, death, erosion/migration, fibrillation or other arrhythmias, lead or accessory breakage (fracture/insulation/lead tip), hematoma/ seroma, inappropriate or inability to provide therapy (pacing/sensing), infection, procedure-related, and component failure. In rare cases severe complications or device failures can occur. For a list of potential adverse events associated with MRI scanning, refer to the MRI Technical Guide. Refer to the physician s manual(s) for specific indications, contraindications, warning/precautions and adverse events. Rx only. (Rev. A) Pacing Systems - ACCOLADE /MRI, ESSENTIO /MRI, VITALIO /MRI, INGENIO /MRI, ADVANTIO INDICATIONS AND USAGE: Boston Scientific pacemakers are indicated for treatment of the following conditions: Symptomatic paroxysmal or permanent second- or third-degree AV block Symptomatic bilateral bundle branch block Symptomatic paroxysmal or transient sinus node dysfunction with or without associated AV conduction disorders (i.e., sinus bradycardia, sinus arrest, sinoatrial [SA] block) Bradycardia-tachycardia syndrome, to prevent symptomatic bradycardia or some forms of symptomatic tachyarrhythmias Neurovascular (vaso-vagal) syndromes or hypersensitive carotid sinus syndromes Adaptive-rate pacing is indicated for patients exhibiting chronotropic incompetence and who may benefit from increased pacing rates concurrent with increases in minute ventilation and/or level of physical activity. Dual-chamber and atrial tracking modes are also indicated for patients who may benefit from maintenance of AV synchrony. Dual chamber modes are specifically indicated for treatment of the following: Conduction disorders that require restoration of AV synchrony, including varying degrees of AV block VVI intolerance (i.e., pacemaker syndrome) in the presence of persistent sinus rhythm Low cardiac output or congestive heart failure secondary to bradycardia. CONTRAINDICATIONS: These Boston Scientific pacemakers are contraindicated in patients who have a separate implanted cardioverter defibrillator (ICD) with transvenous leads. Use of certain pacing modes and/or features available in these Boston Scientific pacemakers is contraindicated for the following patients under the circumstances listed: Unipolar pacing or use of the MV Sensor with a Subcutaneous Implantable Cardioverter Defibrillator (S-ICD) because it may cause inappropriate therapy or inhibition of appropriate S-ICD therapy. Minute Ventilation in patients with both unipolar atrial and ventricular leads Single-chamber atrial pacing in patients with impaired AV nodal conduction Atrial tracking modes for patients with chronic refractory atrial tachyarrhythmias (atrial fibrillation or flutter), which might trigger ventricular pacing Dual-chamber and single-chamber atrial pacing in patients with chronic refractory atrial tachyarrhythmias Asynchronous pacing in the presence (or likelihood) of competition between paced and intrinsic rhythms. WARNINGS: General Read this manual thoroughly before implantation to avoid damage to the pulse generator and/or lead. Such damage can result in patient injury or death. For single patient use only. Do not reuse, reprocess, or resterilize. Always have external defibrillation equipment available during implant and electrophysiologic testing. Using multiple pulse generators could cause pulse generator interaction, resulting in patient injury or a lack of therapy delivery. In response to applicable nonrecoverable or repeat fault conditions, the pulse generator will switch irreversibly to Safety Core operation. Do not kink, twist, or braid the lead with other leads. Do not use atrial tracking modes in patients with chronic refractory atrial tachyarrhythmias. Lead Safety Switch should be programmed Off for patients with an ICD. Unipolar pacing due to Lead Safety Switch is contraindicated for patients with an ICD. Unipolar pacing due to RAAT is contraindicated and should be programmed off for patients with an ICD. If programmed to a fixed atrial Sensitivity value of 0.15 mv, or a fixed sensitivity value of 2.0 mv or less in a unipolar lead configuration in any chamber, the pulse generator may be more susceptible to electromagnetic interference. Advise patients to seek medical guidance before entering environments that could adversely affect the operation of the active implantable medical device. Unless all of the MRI Conditions of Use are met, MRI scanning of the patient does not meet MR Conditional requirements for the implanted system, and significant harm to or death of the patient and/or damage to the implanted system may result. For potential adverse events applicable when the Conditions of Use are met or not met, refer to the MRI Technical Guide. Do not subject a patient with an implanted pulse generator and/or lead to diathermy. PRECAUTIONS: For specific information on precautions, refer to the following sections of the product labeling: clinical considerations; sterilization and storage; implantation; device programming; environmental and medical therapy hazards; hospital and medical environments; home and occupational environments; follow-up testing; explant and disposal; supplemental precautionary information. Advise patients to avoid sources of EMI. The pulse generator may inhibit pacing due to oversensing, or may switch to asynchronous pacing at the programmed pacing rate or at the magnet rate in the presence of EMI. These pulse generators are compatible for use with a Subcutaneous Implantable Cardioverter Defibrillator (S-ICD) when implanted with bipolar leads and programmed to a bipolar pacing configuration. POTENTIAL ADVERSE EVENTS: Potential adverse events include, but are not limited to, the following: allergic/physical/physiologic reaction, death, erosion/migration, fibrillation or other arrhythmias, lead or accessory breakage (fracture/insulation/lead tip), hematoma/seroma, inappropriate or inability to provide therapy (pacing/sensing), infection, procedure related, and component failure. Patients may develop psychological intolerance to a pulse generator system and may experience fear of shocking, fear of device failure, or imagined shocking. In rare cases severe complications or device failures can occur. Refer to the product labeling for specific indications, contraindications, warnings/precautions and adverse events. Rx only. (Rev. C) Sources 1. Patent publication number-us20100331936 A1, BSC internal documents; ELN 2837210, ELN 6283393, ELN 2837210 and ELN 6283393. 2. St. Jude Medical 1488 Tendril Users Manual, Medtronic Capture Fix Novus 5076 Technical Manual, Medtronic Select Secure 3830 Technical Manual, Guidant-Flextend Clinical Report, Medtronic Advisa MRI Trial Report-HRS 2013; 10:685-691, Medtronic MRI SureScan Pacing System Clinical Study Report. 3. INGEVITY Clinical Report: 12 month follow-up, 2015-01. SAMURAI + 1 month follow-up - 2015-02. 4. SAMURAI Clinical Report: MRI visit + 1 month follow-up, 2015-02. 5. St. Jude Medical 1488 Tendril User s Manual, Medtronic Capture Fix Novus 5076 Technical Manual, Medtronic Select Secure 3830 Technical Manual, Guidant-Flextend Clinical Report, Medtronic Advisa MRI Trial Report-HRS 2013; 10:685-691, Medtronic MRI Sure Scan Pacing System Clinical Study Report. 6. INGEVITY Clinical Report: 12 month follow-up, 2015-01. 7. Please refer to the MRI Technical Guide: ImageReady TM MR-Conditional Pacing System as the system is designated as MR-conditional in accordance with specific conditions. 8. Not available with ESSENTIO MRI Pacemaker models. 9. PULSAR MAX Blended Sensor Clinical Trial Results: Chronotropic competence is defined by the Model of the Cardiac Chronotropic Response to Exercise, Wilkoff B, Corey J, Blackburn G. A mathematical model of the cardiac chronotropic response to exercise. Journal of Electrophysiology 1989;3:176-180. Rhythm Management 300 Boston Scientific Way Marlborough, MA 01752-1234 www.bostonscientific.com Medical Professionals: 1.800.CARDIAC (227.3422) Patients and Families: 1.866.484.3268 2017 Boston Scientific Corporation or its affiliates. All rights reserved. CRM-328908-AB APR2017