Pump Therapy - Simple, Proven, and Well Accepted

Similar documents
Clinical Evidence for Insulin Pump Therapy

Performance-powered. The OneTouch. Ping insulin pump and meter-remote.

Pumps & Sensors made easy. OPADA ALZOHAILI MD FACE Endocrinology Assistant Professor Wayne State University

Insulin Pump Therapy in children. Prof. Abdulmoein Al-Agha, FRCPCH(UK)

CLINICAL UTILITY OF CONTINUOUS SUBCUTANEOUS INSULIN INFUSION IN PATIENTS WITH TYPE 1 DIABETES: A MACEDONIAN REPORT

DISCOVER THE POWER OF CONNECTION MINIMED 640G

Clinical Value and Evidence of Continuous Glucose Monitoring

DISCOVER THE POWER OF CONNECTION MINIMED 640G

Continuous Glucose Monitoring (CGM)

DIAGNOSIS OF DIABETES NOW WHAT?

Artificial Pancreas Device System (APDS)

WHAT CAN I DO TO REDUCE MY RISK OF DEVELOPING THE COMPLICATIONS OF TYPE 1 DIABETES?

Updates in Diabetes Technology

PDF of Trial CTRI Website URL -

1. Continuous Glucose Monitoring

Insulin Delivery and Glucose Monitoring Methods for Diabetes Mellitus: Comparative Effectiveness

Anneli, Martina s daughter In better control with her pump since 2011 MY CHILD HAS TYPE 1 DIABETES

Insulin Pumps - External

Diabetes II Insulin pumps; Continuous glucose monitoring system (CGMS) Ernest Asamoah, MD FACE FACP FRCP (Lond)

CGM: Continuous Glucose Monitoring Making Sense of It All AW: ANCO/GEND/1016/0117

Type 1 Diabetes Mellitus. Treatment

Abstract CLINICAL APPLICATIONS. Objectives: Methods: Results: Conclusion: Journal of Diabetes Science and Technology

Clinical practice guidelines in management of type 1 diabetic patients

For patients uncontrolled on multiple daily injections of insulin. A quick-start guide for your practice ALL-DAY CONTROL WITH

Clinical Policy Title: Artificial pancreas device system

Technology for Diabetes: 101 Basic Rules of the Road. Karen Hamon RN, BSN, CDE Stephen Stone MD, FAAP Neil H. White, MD, CDE

A Prospective Evaluation of Insulin Dosing Recommendations in Patients with Type 1 Diabetes at Near Normal Glucose Control: Bolus Dosing

INSPIRED BY GIVE HIM MORE. The MiniMed 670G system is the world s first insulin delivery system that automatically adapts to your child s needs.

Diabetes Technology Continuous Subcutaneous Insulin Infusion Therapy And Continuous Glucose Monitoring In Adults: An Endocrine Society Clinical

INSPIRED BY GIVE HER MORE. The MiniMed 670G system is the world s first insulin delivery system that automatically adapts to your child s needs.

Designed with your patients lives in mind

Advances in Diabetes Care Technologies

Advances in Diabetes Care Technologies

Artificial Pancreas Device Systems. Populations Interventions Comparators Outcomes. pump. pump

Diabetes and Technology. Saturday, September 9, 2017 Aimee G sell, APRN, ANP-C, CDE

Continuous subcutaneous insulin infusion versus multiple dose insulin

R.P.L.M. Hoogma 1*, A.J.M. Spijker 2, M. van Doorn-Scheele 3, T.T. van Doorn 3, R.P.J. Michels 4, R.G. van Doorn 3, M. Levi 4, J.B.L.

Medical Policy An independent licensee of the Blue Cross Blue Shield Association.

Insulin Pump Therapy for Type 2

DIABETES TECHNOLOGY: WHERE ARE WE NOW AND WHERE ARE WE GOING? Presented by: Tom Brobson

CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS Annual Meeting HILTON HEAD ISLAND FRIDAY PRESENTATION

Merck & Co, Inc. Announced Approval of JANUVIA TM (INN: sitagliptin), a new oral treatment of diabetes, by the US FDA

CGM Use in Pregnancy & Unique Populations ELIZABETH O. BUSCHUR, MD THE OHIO STATE UNIVERSITY WEXNER MEDICAL CENTER

April Dear (Editor):

Advances in Diabetes Care Technologies

Presented by Dr. Bruce Perkins, MD MPH Dr. Michael Riddell, PhD

Subject Index. Breastfeeding, self-monitoring of blood glucose 56

WOULD YOU LIKE MORE CONFIDENCE IN YOUR HYPOGLYCAEMIC CONTROL? SMARTGUARD. PROVIDES PREDICTIVE PROTECTION

THE ONLY SYSTEM^ CLINICALLY PROVEN TO REDUCE HYPOGLYCAEMIA

Media Contacts: Amy Rose Investor Contact: Graeme Bell (908) (908)

This certificate-level program is non-sponsored.

Using the Bolus Wizard Calculator

Artificial Pancreas Device Systems. Populations Interventions Comparators Outcomes Individuals: With type 1 diabetes

V-Go : Simple to start, easy to use

Exercise Prescription in Type 1 Diabetes

MINIMED 640G WITH SMARTGUARD GIVES YOU CONFIDENCE TO TAKE CONTROL OF YOUR DIABETES

Basics of Continuous Subcutaneous Insulin Infusion Therapy. Lubna Mirza, MD Norman Endocrinology Associates 2018

Continuous Glucose Monitoring System

Continuous Glucose Monitoring System

Clinical Policy Title: Continuous interstitial glucose monitoring (CGM)

Diabetes Care 34: , 2011

USE OF INSULIN PUMP FOR THE 1 ST TIME IN A GOVERNMENT HOSPITAL JJ HOSPITAL, MUMBAI

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE. Health Technology Appraisal

Development of Optimal Kids Insulin Dosing System Formulas for Young Children with Type 1 Diabetes Mellitus

CareLink. software REPORT REFERENCE GUIDE. Management Software for Diabetes

Diabetes Management: Current High Tech Innovations

WOULD YOU LIKE TO REDUCE THE FEAR OF HYPOGLYCAEMIA FOR YOUR PATIENTS?

Continuous Glucose Monitoring (CGM)

Continuous Subcutaneous Insulin Infusion (CSII) Pumps for Type 1 and Type 2 Adult Diabetic Populations

People with type 1 diabetes and Do It Yourself (DIY) technology solutions ABOUT THIS POSITION STATEMENT

Calgary Diabetes Centre Insulin Pump Therapy: Preparation and Expectations

Clinical Policy Title: Continuous interstitial glucose monitoring (CGM)

Interpretation of Continuous Glucose Monitoring (CGM) Data

Continuous Glucose Monitoring

Insulin pump therapy. Healthy Living with Diabetes

Usefulness of Ambulatory Glucose Profile (AGP) in Diabetes Care

Science Behind Insulin Delivery

MEDICAL POLICY SUBJECT: CONTINUOUS GLUCOSE MONITORING SYSTEMS/ EXTERNAL INSULIN PUMP THERAPY FOR DIABETES EFFECTIVE DATE: 08/17/17

Getting Started. Learning Guide. with Insulin Pump Therapy. PUMP Foundations. for the MiniMed 530G with Enlite

MORE TIME TO BE. The MiniMed 670G system. Less time thinking about managing your diabetes. *1 More time focusing on your day. 2,3

New Insulins and Insulin Delivery Systems. Bruce W. Bode, MD, FACE Atlanta Diabetes Associates Atlanta, Georgia

Reduction in Hypoglycemia and No Increase in A1C with Threshold-Based Sensor-Augmented Pump (SAP) Insulin Suspension: ASPIRE In-Home

Long-term effects of continuous glucose monitoring on HbA 1c levels: An audit

Continuous Glucose Monitoring Devices Pharmacy Policy

Paolo Di Bartolo U.O di Diabetologia Dip. Malattie Digestive & Metaboliche AULS Prov. di Ravenna. Ipoglicemie e Monitoraggio Glicemico

Report Reference Guide

Pumping Insulin is it for your patients?

Insulin Pump Therapy is Equally Effective and Safe in Elderly and Young Type 1 Diabetes Patients

Continuous or Intermittent Glucose Monitoring in Interstitial Fluid

A Two-Center Randomized Controlled Feasibility Trial of Insulin Pump Therapy in Young Children With Diabetes

DIABETES CARE TIPS conzentrate.dk DIABETES CARE TIPS DIABETES CARE TIPS PDF DIABETES CARE - BD NATIONAL DIABETES EDUCATION PROGRAM NIDDK 1 / 6

Fine-tuning of The Dose of Insulin Pump

Continuous Glucose Monitoring System

Insulin Pumps and Continuous Glucose Sensors- Embracing Technology. Susan Cavalier, BS, RN, CDE Manager, Diabetes Educator Sanford Diabetes Education

DEMYSTIFYING INSULIN THERAPY

06/13/17. A. Completed a comprehensive diabetes education program within the past two years; and

Control of Glycemic Variability for Reducing Hypoglycemia Jae Hyeon Kim

CONTINUOUS OR INTERMITTENT GLUCOSE MONITORING IN INTERSTITIAL FLUID

IPS Modern management of childhood diabetes mellitus

Transcription:

Pump Therapy - Simple, Proven, and Well Accepted Innovating for life.

Pump therapy is simple for providers and patients Healthcare Providers Simple outpatient procedure: Low burden and cost to transition patients from MDI Streamlined protocol: Easy candidate selection, initiation, and insulin titration Improved patient outcomes: 3,5,8-13 1-3,8 Lowers A1C and reduces hypoglycemia for better patient management Patients Simple training: Minimal time and knowledge needed to transition to pump therapy Easy to use pump features: Automatic basal and easy bolusing reduces therapy burden Freedom from injections: Simple infusion set changes every 2-3 days Small and light weight: Conveniently fits into lifestyle and insulin is always accessible Medtronic provides support to providers and patients to simplify pump therapy Medtronic offers the following services to HCPs and patients: HCP Pump therapy education and ongoing support Patient Pump therapy demonstration Patient Pump training and troubleshooting Ongoing support to patients to ensure positive clinical outcomes 24 365 Local Support

proven A clinically - safe, effective, and reliable therapy for type 1 diabetes SAFE: 1-3,8 Reduces Hypoglycemia and Diabetic Ketoacidosis 4-7 Pump therapy reduces hypoglycemia in comparison to MDI RUDOLPH: 73.8% reduction in severe hypoglycemia while also reducing A1C BODE: Six fold reduction in severe hypoglycemia during the first year that was sustained for years 2, 3, and 4 BOLAND: 50% reduction in severe hypoglycemia after 12 months of therapy EFFECTIVE: 3,5,8-13 8,14 Reduces A1C and Glycemic Variability A1C (%) 8 A1C / values are mean ± SEM 5 Nations Trial: Randomized control trial conducted in 11 European centers 272 type 1 patients were transitioned to either MDI or pump therapy for 8 months, then crossover Pump therapy resulted in a 0.85% A1C reduction while also reducing glucose fluctuation by 0.8 mmol/l (15mg/dL) RELIABLE: A meta-analysis of 1,547 patients across 52 studies demonstrated pump therapy to consistently reduce A1C 15 in comparison to MDI A1C Duration 9.5 9.0 8.5 8.0 7.5 7.0 6.5 6.0 5.5 5.0 Brutomesso (n=138) 89 months Bell (n=58) 36 months 3,5,9-13 Reduction in A1C Rudolph (n=107) 36 months Chantelau (n=116) 54 months Boland (n=25) 12 months Pump Therapy MDI Maniatis (n=56) 12 months Litton (n=9) 13 months 7 clinical articles representing 509 patients concluded pump therapy reduces A1C in comparison to MDI 3,5,9-13

well accepted Pump Therapy is around the World and in India Globally >800,000 patients use pump therapy to manage their diabetes 17 120 17 Physicians from over countries prescribe pump therapy with confidence In India >5,000 patients use pump therapy to manage their diabetes 17 >250 physicians prescribe pump therapy 17 Pump Therapy Approved by various International Regulatory Bodies Health Canada Health Canada, Canada FDA, USA TGA, Australia Health Safety Regulation PMDA, Japan SFDA, China CE, European Union MHRA, UK Simple, Proven and Well Accepted

Insulin Pump Therapy: The India Experience Physician Real Life Experiences Type 1 Adult: I am very pleased that we were able to solve the problem of the nocturnal hypoglycemia, which was the complaint in her pre pump visits Dr. S. K. Wangnoo Chief Endocrinologist, Apollo Hospital, Delhi. Type 1 Pediatric: Due to the unpredictability of long acting insulin it was very difficult to obtain normal blood sugar levels with injections. The Insulin Pump delivers fastacting insulin only, just like the pancreas. We are pleased with the clinical outcomes of this case the progress Segar has made. Dr. Sanjeev R. Phatak & Dr. P. S. Iyengar Sterling Hospital, Ahmedabad. Type 1 Pregnant Adult: Thanks to Insulin Pump Therapy, this patient s glucose levels improved and her complications have settled down. It is indeed a boon for such patients, helping them to achieve and maintain a good glycemic control, specially in pregnancy when blood glucose levels can be ex tremely dangerous, both for the mother and growing foetus. Dr. Rema Mohan, Dr. V. Mohan, Dr. Shalini B. & Dr. N. G. Sastry Dr. Mohan s Diabetes Speciality Centre, Chennai. TM Minimed Veo Insulin Pump Patient Testimonials I am feeling better in general because now I control my diabetes rather than diabetes control my life. Female, 28 years old Type 1 diabetes, Delhi. Our son is feeling much better now that he is on an Insulin Pump. The Pump is easy to program. We are feeling less worried that our son will have a severe low blood sugar in the middle of the night. Parents, male 12 years old Ahmedabad. 98% of patients continue pump therapy long term 16 Prescribe pump therapy with confidence for your type 1 patients.

References: 1. Rudolph JW, Hirsch IB. Endocrine Practice. 2002; 8: 401 405. 2. Bode, B W, Steed RD, Davidson PC. Diabetes Care. 1996;19:324-7. 3. Boland EA, Grey M, Oesterle A, et al. Diabetes Care. 1999; 22:1779 84. 4. Plotnick LP, et al. Diabetes Care. 2003; 26:1142-1146. 5. Bruttomesso D. Diabet Med. 2002; 19:628-634. 6. Linkeschova M, et al. Diabetes 2002; 19: 746-751. 7. Steindel BS, et al. Diabetes Res Clin Pract. 1995; 27:199-204. 8. Hoogma RP, et al. Diabetic Med. 2005; 23:141-147. 9. Bell DSH, et al. Endocr Pract. 2000; 6:357-360. 10. Rudolph DS, et al. Endocr Pract. 2002; 8:401-405. 11. Chantelau E, et al. Diabetologia. 1989;32:421-426. 12. Maniatis AK, et al. Pediatrics. 2001;107:351-356. 13. Litton J, et al. J Pediatr. 2002;141:490-495. 14. Lepore, et al. Diabetes. 2000; 49: 2142-2148. 15. Weissberg Benchell J, et al. Diabetes Care. 2003; 26:1079-1087. 16. Bode BW, Tamborlane WV, Davidson PC. Postgraduate Medicine. 2002; 111:69-77. 17. Medtronic Internal data. For the use of a registered medical practitioner / hospital / laboratory only India Medtronic Pvt. Ltd. 1241 Solitaire Corporate Park, Bldg. 12, 4th Floor, Andheri-Ghatkopar Link Road, Andheri (E), Mumbai 400 093 Tel: +91 22 3307 4700/01/02/03 Fax: +91 22 3307 4704 e-mail: rs.indiadiabeteshelpdesk@medtronic.com INDCSII-HCP-0313-002EN@2013 Medtronic, MiniMed Inc. All rights reserved.