Locking Plate in Proximal Tibial Fracture: A Correlation between the Coronal Alignment of Tibia and Joint Screw Angle

Similar documents
Distal femoral fracture with subsequent ipsilateral proximal femoral fracture

Locked Plating: Clinical Indications

Bicondylar tibial plateau fracture treated by open reduction and fixation with unilateral locked plating

LISS DF and LISS PLT. Less Invasive Stabilization Systems for Distal Femur and Proximal Lateral Tibia.

Techique. Results. Discussion. Materials & Methods. Vol. 2 - Year 1 - December 2005

Technique Guide. LCP Proximal Femoral Hook Plate 4.5/5.0. Part of the LCP Periarticular Plating System.

Minimally Invasive Plating of Fractures:

Distal Femur Fractures: Tips and Tricks for Plating and Nailing? Conflict of Interest 9/24/2015

Treatment of Schatzker Type V and VI Tibial Plateau Fractures Using a Midline Longitudinal Incision and Dual Plating

ICUC Paper. Variable Angle Locked Screw (VAL): from concept to application. A. Fernández Dell'Oca, P. Regazzoni, S.M. Perren.

Advantage and limitations of a minimally-invasive approach and early weight bearing in the treatment of tibial shaft fractures with locking plates

Results of proximal tibial fractures managed with periarticular locking plates: A series of 34 cases

Technique Guide. TomoFix Osteotomy System. A comprehensive plating system for stable fixation of osteotomies around the knee.

Technique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

Early results with the new internal fixator systems LCP and LISS : A prospective study

2017 Resident Advanced Trauma Techniques Course COMPLICATIONS / CHALLENGES MALUNIONS/DEFORMITY

Story continues below ADVERTISEMENT

LCP Medial Proximal Tibial Plate 4.5/5.0. Part of the Synthes LCP periarticular plating system.

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

Periarticular Aiming Arm Instruments for LCP Proximal Tibial Plate 4.5/5.0. Part of the LCP Periarticular Aiming Arm Instrument System (large).

Complication Rate and Pitfalls of Temporary Bridging External Fixator in Periarticular Communited Fractures

Results in treatment of distal femur fractures using polyaxial locking plate

LCP Anterior Ankle Arthrodesis Plates. Part of the Synthes Locking Compression Plate (LCP) System.

AO / Synthes Proximal Posterior Medial Tibia Plate. Tibial Plateau Fx. Osteosynthesis

A comparative study of less invasive stabilization system and titanium elastic nailing for subtrochanteric femur fractures in older children

LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system.

One Stage Treatment of Open Proximal Tibia Fractures by Minimally Invasive Technique Using Locked Plate

Minimally Invasive Surgery by Angular Stability Systems in Proximal Tibia Fractures Biomechanical Characteristics and Preliminary Results

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system.

Minimally Invasive Percutaneous Plate Osteosynthesis Does Not Increase Complication Rates in Extra-Articular Distal Tibial Fractures

Correction of Traumatic Ankle Valgus and Procurvatum using the Taylor Spatial Frame: A Case Report

LCP Condylar Plate 4.5/5.0. Part of the LCP Periarticular Plating System.

3.5 MM VA-LCP PROXIMAL TIBIA PLATE SYSTEM

The multitude of options for the treatment of periprosthetic

MINIMALLY INVASIVE PLATE OSTEOSYNTHESIS FOR DISTAL RADIUS FRACTURES: SURGICAL TECHNIQUE M. TOBE 1, K. MIZUTANI 1, Y. TSUBUKU 1, Y.

Minimally invasive plate osteosynthesis for tibial plateau fractures

Evaluation of role of fibula in functional outcome of tibial plateau fractures

Complex angular and torsional deformities (distal femoral malunions)

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plate Aiming Instruments. Part of the 3.5 mm LCP Percutaneous Instrument System.

ROTATIONAL PILON FRACTURES

Technique Guide. 3.5 mm LCP Proximal Tibia Plate. Part of the Synthes Small Fragment LCP System.

Tibial deformity correction by Ilizarov method

LCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability.

LCP Anterolateral Distal Tibia Plate 3.5. The low profile anatomic fixation system with optimal plate placement and angular stability.

Original Research Article

Alignment of the femoral component in a mobile-bearing unicompartmental knee arthroplasty Kort, N. P.; van Raay, J. J. A. M.; Thomassen, B. J. W.

Comparison of outcome of unilateral locking plate and dual plating in the treatment of bicondylar tibial plateau fractures. Lee et al.

CASE REPORT. Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report

Distal Femur Fractures in The Elderly The Ideal Construct

ISSN (O): ; ISSN (P): Short Term Evaluation of Distal Femoral Fracture Fixation by Locking Plate.

Back out of Locking Pin with Hinge Fracture after High Tibial Osteotomy

Case Report Dynamization of the locking compression plate for treating tibia nonunion: a case report

LESS INVASIVE STABILIZATION SYSTEM (LISS) IN THE TREATMENT OF DISTAL FEMUR FRACTURES

Technique Guide. Less Invasive Stabilization System (LISS). Allows percutaneous plate insertion and targeting of screws in the proximal tibia.

Angular Malalignment in Subtrochanteric and Proximal Shaft Femur Fractures after Intramedullary Nailing using SIGN Nails

CORRECTIVE OSTEOTOMY BRINGING THE PLAN TO THE BONE (TRIGONOMETERY, GUIDE WIRES, SLA MODELING AND ART)

Locked Plating: Biomechanics and Biology

Bicondylar tibial plateau fractures involving the posteromedial fragment : morphology based fixation

EVOS MINI with IM Nailing

Open reduction; plate fixation 1 Principles

PediLoc Extension Osteotomy Plate (PLEO)

Zimmer MIS Periarticular 3.5mm Proximal Tibial Locking Plate

The Journal of the Korean Society of Fractures Vol.13, No.3, July, 2000

Alignment Rod. For intraoperatively confirming correction of the mechanical leg axis.

Minimally Invasive Plate Osteosynthesis Using a Screw Compression Method for Treatment of Humeral Shaft Fractures

OptiLock Periarticular Plating System For Distal Tibial Fractures. Surgical Technique

LCP Distal Femur Plates. Shape based on Distal Femur LISS Plate design.

The Journal of the Korean Society of Fractures Vol.16, No.1, January, 2003

BRIDGE PLATING OF COMMINUTED SHAFT OF FEMUR FRACTURES

Plate vs Nail for Distal Tibia Fxs

Retrograde Intramedullary Nailing for Periprosthetic Supracondylar Fractures of the Femur after Total Knee Arthroplasty

Arthrex Open Wedge Osteotomy Technique Designed in conjunction with:

Multiapical Deformities p. 97 Osteotomy Concepts and Frontal Plane Realignment p. 99 Angulation Correction Axis (ACA) p. 99 Bisector Lines p.

Reliability of Radiographic Assessment of Tibial Plateau Fracture

LCP Condylar Plate 4.5/5.0. Part of the LCP Periarticular Plating System.

Case Report. Antegrade Femur Lengthening with the PRECICE Limb Lengthening Technology

Relationship between Lateral Femoral Bowing and Varus Knee Deformity Based on Two-Dimensional Assessment of Side-to-Side Differences

Less Invasive Stabilization System for distal femoral fracture an early experience in Bir hospital

Locking Plates for Extremity Fractures A Technology Overview EVIDENCE TABLES

LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system.

Open Access Case Report DOI: /cureus.599. Ashok K. Rathod 1, Rakesh P. Dhake 1, Aditya Pawaskar 1

Treatment of distal femur fractures in a regional Australian hospital

Treatment of Diaphysio-Metaphyseal Fracture of Tibia by Intramedullary Nail in Combination with Poller Screw

Medial Malleolus Fracture Fixation in the Setting of Concomitant Tibial Shaft Fractures

Zimmer MIS Periarticular Distal Femoral Locking Plate

SEVERE VARUS AND VALGUS DEFORMITIES TREATED BY TOTAL KNEE ARTHROPLASTY

TWO STAGE RECONSTRUCTION PROTOCOL IN MANAGEMENT OF HIGH-ENERGY PROXIMAL TIBIA FRACTURES (SCHATZKER, TYPE IV-VI)

DISCLOSURES Hassan R. Mir, MD, MBA, FACS

Orthopedics in Motion Tristan Hartzell, MD January 27, 2016

Technique Guide. 4.5 mm LCP Proximal Tibia Plates. Part of the Synthes LCP Periarticular Plating System.

NCB Distal Femur System. Surgical Technique

OPERATIVE TREATMENT OF THE INTERCONDYLAR FRACTURE OF THE FEMUR

Increasing surgical freedom Restoring patient function

VA-LCP Condylar Plate 4.5/5.0. Part of the Synthes Variable Angle Periarticular Plating System.

Technique Guide. 3.5 mm LCP Periarticular Proximal Humerus Plate. Part of the Synthes locking compression plate (LCP) system.

Prospective study of management of Schatzker s type V and VI tibial plateau fractures by different types of plate osteosynthesis

4.5 mm VA-LCP. Part of the Variable Angle Periarticular Plating System

PediLoc 3.5mm and 4.5mm Contour Femur Plate Surgical Technique

Plate Fixation Options

Transcription:

Original Article http://dx.doi.org/10.3349/ymj.2013.54.3.720 pissn: 0513-5796, eissn: 1976-2437 Yonsei Med J 54(3):720-725, 2013 Locking Plate in Proximal Tibial Fracture: A Correlation between the Coronal Alignment of Tibia and Joint Screw Angle Jong-Keon Oh, 1 Jin-Ho Hwang, 2 Lalrinliana Varte, 2 Jae-Han Ko, 2 Chang-Wug Oh, 3 Duk-Young Jung, 4 Hyonggin An, 5 and Jae-Woo Cho 1 1 Department of Orthopaedic Surgery, Korea University School of Medicine, Guro Hospital, Seoul; 2 Department of Orthopaedic Surgery, Yonsei University College of Medicine, Seoul; 3 Department of Orthopaedic Surgery, School of Medicine, Kyungpook National University, Daegu; 4 Technical Support Team, Techno-Park, Senior Products Industrial Center, Busan; 5 Department of Biostatistics, College of Medicine, Korea University, Seoul, Korea. Received: May 2, 2012 Revised: July 11, 2012 Accepted: July 12, 2012 Corresponding author: Dr. Jin-Ho Hwang, Department of Orthopaedic Surgery, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, Seoul 120-752, Korea. Tel: 82-2-2228-2185, Fax: 82-2-363-1139 E-mail: osjinho@naver.com The authors have no financial conflicts of interest. Purpose: The purpose of this study is to evaluate the relationship between the angle formed between the proximal most screw through the locking compression plate-proximal lateral tibia (LCP PLT) and the joint line, and to evaluate if this angle can be used intraoperatively as an assessment tool to determine normal alignment of the tibia in the coronal plane. Materials and Methods: There are two parts to this study: in the first part, LCP PLT was applied to 30 cadaveric adult tibia. The angle between the joint line and the proximal most screw was measured and termed as the joint screw angle (JSA). In the second part, 56 proximal tibial fractures treated with LCP PLT were retrospectively studied. Two angles were measured on the radiographs, the medial proximal tibial angle (MPTA) and the JSA. Their relationship was analyzed statistically. Results: The average JSA was 1.16 degrees in the anatomical study. Statistical analysis of the clinical study showed that the normal MPTA had a direct correlation with an acceptable JSA. Conclusion: We therefore conclude that the JSA can be used intraoperatively to assess the achievement of a normal coronal axis. Key Words: Proximal tibial fracture, locking plate, tibial coronal alignment INTRODUCTION Copyright: Yonsei University College of Medicine 2013 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non- Commercial License (http://creativecommons.org/ licenses/by-nc/3.0) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited. Unilateral plating for proximal tibial fractures with conventional plating system has often been blamed for secondary loss of reduction due to the lack of angular stability. 1-3 Dual plating, however, is commonly associated with serious complications involving soft tissue breakdown. 4,5 The introduction of anatomically pre-contoured locking plate such as less invasive stabilization system (LISS), Locking compression plates-proximal lateral tibia (LCP PLT, Synthes, West Chester, PA, USA) and biological plating concept, has made unilateral plating for complex proximal tibial fractures very popular in recent years. 6-19 With this new technique, union rate has increased without bone grafting, and good clinical results have been 720 Yonsei Med J http://www.eymj.org Volume 54 Number 3 May 2013

Alternate Guideline to Assess Coronal Alignment reported. The main problem with this technique, however, is malalignment. 8,12 Although many technical tips have been described to assess the alignment intraoperatively, 20 there is still a need for more methods which could be used to assess the alignment intraoperatively. The purpose of this study is to evaluate whether the angle formed between the proximal most screw through the LCP PLT and the joint line has any relationship with the coronal plane alignment of the tibia. With this objective in mind, we measured the angle between the proximal most locking screw through LCP PLT and the joint line in normal adult tibia of cadaver limbs [this angle was termed as the joint screw angle (JSA)] and established a normal JSA range. Then, we evaluated our results in a clinical setting to assess if the JSA can be used as a radiological guideline intraoperatively, for the assessment of final coronal alignment. Our hypothesis is that the position of the proximal most screw through LCP PLT in relation to the joint line can be used as a rough guideline to assess the alignment in the coronal plane. MATERIALS AND METHODS Our basic methodology was to measure the angle between the proximal most locking screw through LCP PLT and the joint line in normal adult tibia of cadaver limbs (this angle was termed as the JSA ) and to establish a normal JSA range. Subsequently, we evaluated our results in a clinical setting to assess if the normal JSA has any constant relationship with the coronal alignment of tibia. This was done in two parts. In the first part, we conducted a cadaveric study using 30 adult tibial bones. In the second part, in a clinical set up, we retrospectively analyzed the relationship between the postoperative alignment and the radiological guideline (JSA). The study was approved by the Konkuk University Hospital Institutional review board. Anatomical study We retrieved 30 tibial shafts from adult cadavers of 24 males and 16 females. The mean age was 62 years (range 31-90 years). An 11-hole LCP PLT was applied to the lateral aspect of the proximal tibia. The LCP PLT was applied such that the plate nestled up with the lateral aspect of proximal metaphysis and was parallel to the axis of the tibial shaft. The two proximal most locking screws were then placed. One locking screw was placed on the shaft according to the manufacturer s recommendations. We grossly observed the plate and bone construct to see if there was any part where the plate did not fit to the bone surface well. The anteroposterior (AP) and lateral views of the proximal tibia were taken. On the AP image, we measured the angle between proximal tibial joint line and the locking screw, and termed the A B C Fig. 1. (A) JSA=0: proximal most screw (PMS) is parallel to the joint line. (B) JSA (-): PMS tilted in varus with tip pointing towards joint line. (C) JSA (+): PMS tilted in valgus with tip pointing away from joint line. JSA, joint screw angle. Yonsei Med J http://www.eymj.org Volume 54 Number 3 May 2013 721

Jong-Keon Oh, et al. angle as JSA (Fig. 1A). We designated a negative value to the JSA when the screw was tilted in a varus position to the joint line, such that the tip of the screw pointed towards the joint line, resulting in a lateral opening angle (Fig. 1B). If the screw was tilted in a valgus position, such that the tip pointed away from the joint line, resulting in a medial opening angle, we described it as a positive JSA value (Fig. 1C). Clinical study We retrospectively reviewed 56 cases of proximal tibial fractures that were treated with LCP PLT. They comprised 44 males and 12 females. The mean age was 52 years (range, 30-88 years). Forty-nine fractures were treated in an acute setting within 2 weeks after the injury. There were six nonunion and one malunion of the proximal metaphysis. The fresh fractures were classified according to the AO-OTA classification. They were of the following types: 41A1(2), 41A2(1), 41A3(7), 41B2(1), 41C2(1), 41C3(18), 42A1(1), 42A2(3), 42A3(1), 42B2(5), 42C1(1), 42C2(3), 42C3(5). All operations were performed by two experienced trauma surgeons or they were performed under their guidance. In all the fractures, the reduction was achieved first and then LCP PLT was applied via a lateral approach. The plate was applied over the lateral surface of the tibia, anterior to fibular articular surface of the tibia. The first screw was placed in the mid diaphysis and then the proximal screws were inserted. All efforts were made to align the plate well with the tibial surface proximally and with the shaft. X-ray analysis The radiologic analysis formed the backbone of our study. This was done based on the radiograms from 56 patients. In 29 of these patients, we could retrieve the intraoperative images as well as the postoperative radiographs. For the remaining 27 patients, we had the postoperative radiographs only. 1) Postoperative radiograms were taken at approximately 4-20 weeks postoperatively or as soon as patient was able to stand and bear weight on the operated leg. Postoperative radiograms were standing orthoradiograms of the lower extremity centering at the knee joint with the patient facing the radiographic tube and the patella pointing forward. 2) Intraoperative images were taken with the patient positioned supine, knee in full extension, patella pointing towards the ceiling, and the image intensifier aligned perpendicular to the knee joint. Following measurements were made on the radiograms. Two angles were measured: (1) The medial proximal tibial angle (MPTA; angle mea- sured on the medial side formed between the tibial plateau line and the line along the tibial axis) was measured in both the tibiae on the postoperative orthoradiogram and the difference was calculated. Malalignment was defined as a difference of more than 5 in the MPTA. In three cases with bilateral proximal tibial fractures, the average population MPTA (87 ) was used as a reference angle. (2) The JSA was measured simultaneously on both intraoperative and postoperative images in 29 cases in whom the C-arm images were also saved in addition to the postoperative X-rays. For the remaining 27 patients, the JSA was measured only on the postoperative orthoradiogram. The screw was considered acceptable if it is approximately parallel to the joint line and the JSA was found to be in the range of 0±5. In the 29 patients, we did not find a difference of more than 1 degree between the JSA on the intraoperative image and the JSA on the postoperative image. On the basis of this interim analysis, we decided to use the postoperative measurement of the JSA as an alternative to the JSA on the intraoperative image in the remaining 27 patients. We then statistically analyzed the relationship between the JSA and the postoperative malalignment (MPTA) in all 56 cases. All the radiographic measurements were made by two independent blinded observers (two orthopedic surgeons: first and corresponding authors). Statistical analysis Inter-observer variance was assessed using the paired t test. No difference was found between the observations made by the two observers (p<0.05). Patients were categorized into two groups based on their postoperative coronal plane alignment: one group with normal alignment (MPTA within ±5 of the contralateral normal limb) and the other group with malalignment. Patients were also divided into two groups based on the degree of the JSA: one group with acceptable JSA (within ±5 ) and the other group with unacceptable JSA. The kappa statistics was calculated to assess the agreement of alignment status between the MPTA and the JSA. We also conducted an exact test version of McNemar test to evaluate the agreement between MPTA and JSA. In this test, the null hypothesis was agreement between two variables while the alternative hypothesis was difference between two variables. All analyses were conducted using the SAS version 9.1.3 (SAS Institute Inc., Cary, NC, USA). The level of significance was set at 0.05. 722 Yonsei Med J http://www.eymj.org Volume 54 Number 3 May 2013

Alternate Guideline to Assess Coronal Alignment RESULTS Anatomical study On gross observation, we found that the LCP PLT fits to the lateral aspect of the proximal tibiae fairly well. However, we also found that the head of the plate tends to stay apart from the lateral aspect of the lateral condyle by a few millimeters. In 30 specimens that we studied, the JSA was -2 on an average (ranged from 0 to -7 ). In 22 cases (73%), the proximal locking screw was almost parallel to the joint line (JSA -2 to 0 ). In 7 patients (24%), the JSA was between -5 and -2, and the JSA was -7 in one specimen with severe osteoarthritis. This particular bone showed severe osteoarthritis with varus inclination of the joint line (MPTA 82). In this case, the unacceptable JSA was due to an abnormal inclination of the joint line. Two other specimens showed degenerative changes and a varus inclination of the joint line of 5 in the coronal plane and a JSA of 5. None of the specimens showed a positive JSA. Clinical and radiological study Our clinical and radiographic retrospective study yielded the following results. In 49 of the 56 patients (87.5%), the MPTA was found to be acceptable and within the normal range (within 5 of the contralateral normal limb or average of the population). In the remaining 7 patients (12.5%), there was malalignment in the coronal plane and the MPTA was out of the normal range. Out of the 49 patients with normal alignment, the JSA was found to be in the acceptable range in 47 patients (95.92%), and in the unacceptable range in the remaining 2 patients. In the 7 patients with malalignment, the JSA was unacceptable in 4 patients (57.14%) and acceptable in the remaining 3 patients. Among the 50 patients with a normal JSA, 47 patients [94% (47/50 100)] were found to have a normal alignment. Out of the 6 patients with an abnormal JSA, 4 patients (67%) showed malalignment. The kappa value for the measure of agreement between JSA and MPTA was 0.565 (95% confidence interval: 0.225, 0.905) (Table 1). The p-value from the exact test version of McNemar s test was 1.000, indicating a good agreement between JSA and MPTA and clearly stating that the association between the MPTA and the JSA was very relevant and not just coincidental. DISCUSSION Although the minimal invasive Locking plate fixation has shown promising results in reducing infections (4%) and achieving high rates of union, it has given rise to more troublesome, alignment related issues. The published data in literature show varied complication rates of this technique. According to Ricci, et al., 14 obtaining proper alignment with the use of LISS is technically demanding. Malalignment in the coronal plane after the use of LISS in treatment of various types of proximal tibial fractures has been reported in many papers. 8,12,15,21 Our anatomical study was carried out to identify the relationship between the coronal plane alignment and the JSA. We found, the proximal most screw through LCP PLT to be parallel to the joint line or within ±5 in 29 of 30 cadaveric tibial bones. Only in 1 grossly arthritic specimen, the JSA was out of the acceptable range (-7 ) which was due to the abnormal inclination of the joint line (MPTA 82 ). Thus, the relationship established was that the JSA was 5 or less in nearly all the normal tibial bones, except in the severely arthritic bones with abnormal inclination of the joint line. The relationship is difficult to establish in severely arthritic Table 1. The Negative Predictive Value for the JSA Alignment JSA Normal Malaligned Total Nos. Percentage Nos. Percentage Acceptable Nos. 47 94% 3 6% 50 Percentage 95.92% 42.86% Unacceptable Nos. 2 33.33% 4 66.67% 6 Percentage 57.14% 4.08% Total 49 7 56 JSA, joint screw angle; MPTA, medial proximal tibial angle. Alignment: normal when MPTA is 87±5 otherwise it is Malaligned. JSA is acceptable if it is 0±5 otherwise it is unacceptable. Kappa=0.565 (95% confidence interval: 0.225, 0.905). Positive predictivity=true positive/total positive=47/50=0.94 (94%). Negative predictivity=true negative/total negative=4/6=0.67=67%. Yonsei Med J http://www.eymj.org Volume 54 Number 3 May 2013 723

Jong-Keon Oh, et al. bones, and thus we would generally limit the results of our study to bones which do not show severe arthritis. We further set out to evaluate if this relationship holds true in a clinical setting and if it could be used intraoperatively to assess the alignment in the coronal plane. On a retrospective analysis, the relationship that we found between the JSA and the MPTA had a high positive prediction of 94% (47/50); i.e. there is a great chance of having a normal alignment if the JSA is within the normal acceptable range. The results of our anatomic study and clinical correlation indicate that an acceptable JSA does point towards a normal MPTA and the relationship cannot be explained by chance alone. The relationship between the JSA and the MPTA could thus be used as an additional tool to evaluate the coronal alignment. However, out of 6 patients with an unacceptable JSA, there were 4 cases of an abnormal MPTA, and 2 cases of a normal MPTA. These 2 cases of a normal MPTA with an unacceptable JSA can be explained by the fact that there are various ways in which the plate could be positioned over the tibia due to various kinds of possible mismatches between the proximal tibia and the pre-contoured plate. If the position is like that of an impingement fit with the distal part of the plate away from the shaft and the proximal part fitting well on the shaft as described by Goyal, et al., 22 the screw and the JSA will be in a valgus position over an anatomically well aligned tibia. Preservation of the normal anatomic alignment is important in achieving a favorable outcome. Blokker, et al. 6 found unsatisfactory results in 100% of the patients with inadequate anatomical reduction. In many series, the authors underscore the importance of good technical tricks to avoid malalignment. Cole, et al. 8 emphasized the importance of good intraoperative radiographs to decrease the incidence of malreduction. They tried to underscore the importance of good radiography techniques; i.e. taking radiographs on a large flat plate before the placement of screws, using fluoroscopy & strategic bumps supporting the distal fragment in order to achieve a good postoperative alignment. Krettek, et al. 20 described the cable technique to avoid the coronal plane malalignment. Although this technique is quite useful when the alignment is evaluated after the fixation is over, it is often not feasible to have two assistants holding the cable and moving the C-arm from the top to the bottom while the alignment is maintained. On the other hand, the JSA can be easily measured on a single C-arm AP image. We did not find any other study which specifically dealt with alignment issues and addressed them. We were also unable to find any mention of the JSA or of its relationship to the alignment in the manufacturer s recommendation. Hence, we are not certain whether or not they intended to orient the first screw parallel to the joint line. An ideally placed plate, is likely to demonstrate the relationship between the MPTA and the JSA. In view of the above limitations, we can state that the JSA may not be used as a standalone assessment tool, however, it can rather be used as an adjunct to the other techniques of assessment of alignment, since it points very well towards the type of alignment we are likely to achieve and may also provide an indication on the occurrence of malalignment. In conclusion, we can safely conclude from our observation that the JSA can be used intraoperatively as a rough guideline to assess the achievement of a final normal alignment in the coronal plane when applying a LCP PLT/LISS internal fixator for fractures of the proximal tibia. REFERENCES 1. Krieg JC. Proximal tibial fractures: current treatment, results, and problems. Injury 2003;34 Suppl 1:A2-10. 2. Waddell JP, Johnston DW, Neidre A. Fractures of the tibial plateau: a review of ninety-five patients and comparison of treatment methods. J Trauma 1981;21:376-81. 3. Wu CC. Salvage of proximal tibial malunion or nonunion with the use of angled blade plate. Arch Orthop Trauma Surg 2006;126:82-7. 4. Moore TM, Patzakis MJ, Harvey JP. Tibial plateau fractures: definition, demographics, treatment rationale, and long-term results of closed traction management or operative reduction. J Orthop Trauma 1987;1:97-119. 5. Young MJ, Barrack RL. Complications of internal fixation of tibial plateau fractures. Orthop Rev 1994;23:149-54. 6. Blokker CP, Rorabeck CH, Bourne RB. Tibial plateau fractures. An analysis of the results of treatment in 60 patients. Clin Orthop Relat Res 1984:193-9. 7. Cole PA, Zlowodzki M, Kregor PJ. Less Invasive Stabilization System (LISS) for fractures of the proximal tibia: indications, surgical technique and preliminary results of the UMC Clinical Trial. Injury 2003;34 Suppl 1:A16-29. 8. Cole PA, Zlowodzki M, Kregor PJ. Treatment of proximal tibia fractures using the less invasive stabilization system: surgical experience and early clinical results in 77 fractures. J Orthop Trauma 2004;18:528-35. 9. Egol KA, Su E, Tejwani NC, Sims SH, Kummer FJ, Koval KJ. Treatment of complex tibial plateau fractures using the less invasive stabilization system plate: clinical experience and a laboratory comparison with double plating. J Trauma 2004;57:340-6. 10. Goesling T, Frenk A, Appenzeller A, Garapati R, Marti A, Krettek C. LISS PLT: design, mechanical and biomechanical characteristics. Injury 2003;34 Suppl 1:A11-5. 11. Gösling T, Schandelmaier P, Marti A, Hufner T, Partenheimer A, 724 Yonsei Med J http://www.eymj.org Volume 54 Number 3 May 2013

Alternate Guideline to Assess Coronal Alignment Krettek C. Less invasive stabilization of complex tibial plateau fractures: a biomechanical evaluation of a unilateral locked screw plate and double plating. J Orthop Trauma 2004;18:546-51. 12. Gosling T, Schandelmaier P, Muller M, Hankemeier S, Wagner M, Krettek C. Single lateral locked screw plating of bicondylar tibial plateau fractures. Clin Orthop Relat Res 2005;439:207-14. 13. Phisitkul P, McKinley TO, Nepola JV, Marsh JL. Complications of locking plate fixation in complex proximal tibia injuries. J Orthop Trauma 2007;21:83-91. 14. Ricci WM, Rudzki JR, Borrelli J Jr. Treatment of complex proximal tibia fractures with the less invasive skeletal stabilization system. J Orthop Trauma 2004;18:521-7. 15. Schütz M, Kääb MJ, Haas N. Stabilization of proximal tibial fractures with the LIS-System: early clinical experience in Berlin. Injury 2003;34 Suppl 1:A30-5. 16. Schütz M, Müller M, Regazzoni P, Höntzsch D, Krettek C, Van der Werken C, et al. Use of the less invasive stabilization system (LISS) in patients with distal femoral (AO33) fractures: a prospective multicenter study. Arch Orthop Trauma Surg 2005;125:102-8. 17. Stannard JP, Wilson TC, Volgas DA, Alonso JE. Fracture stabili- zation of proximal tibial fractures with the proximal tibial LISS: early experience in Birmingham, Alabama (USA). Injury 2003;34 Suppl 1:A36-42. 18. Stannard JP, Wilson TC, Volgas DA, Alonso JE. The less invasive stabilization system in the treatment of complex fractures of the tibial plateau: short-term results. J Orthop Trauma 2004;18:552-8. 19. Weight M, Collinge C. Early results of the less invasive stabilization system for mechanically unstable fractures of the distal femur (AO/OTA types A2, A3, C2, and C3). J Orthop Trauma 2004;18: 503-8. 20. Krettek C, Miclau T, Grün O, Schandelmaier P, Tscherne H. Intraoperative control of axes, rotation and length in femoral and tibial fractures. Technical note. Injury 1998;29 Suppl 3:C29-39. 21. Beck M, Gradl G, Gierer P, Rotter R, Witt M, Mittlmeier T. [Treatment of complicated proximal segmental tibia fractures with the less invasive stabilization locking plate system]. Unfallchirurg 2008;111:493-8. 22. Goyal KS, Skalak AS, Marcus RE, Vallier HA, Cooperman DR. Analysis of anatomic periarticular tibial plate fit on normal adults. Clin Orthop Relat Res 2007;461:245-57. Yonsei Med J http://www.eymj.org Volume 54 Number 3 May 2013 725