Vital Signs Monitor Series (VSM) Outline Train the Trainer

Similar documents
How To Measure Vital Signs

AMERICAN ASSOCIATION OF SLEEP TECHNOLOGISTS TECHNICAL GUIDELINE FOR PATIENT ASSESSMENT AND VITAL SIGNS MEASUREMENT AND DOCUMENTATION

Ambulatory Services Orientation & Skill Review Skill Performance Checklist: Vital Signs. Name: Date:

BLINDED MODE USERS GUIDE SUPPLEMENT

VITAL SIGNS MONITORING. RVS-100/200 ri-vital. Vital Signs Patient Monitors

HOME BP USER INSTRUCTIONS

Chapter 29 1/8/2018. Vital Signs. Measuring and Reporting Vital Signs. Key Terms

Clinical Research Coordinator Skills Program

Vital Signs. Vital Signs. Vital Signs

SureTemp Plus. REF 690 and 692. Directions for use

Vital Signs and Oxygen Administration

Blood Glucose Monitoring System. Owner s Booklet

Measuring body temperature, blood pressure, pulse, respiratory rate and oxygen saturation

Managing Blood Pressure: It Takes a Team

MANUAL BLOOD PRESSURE MONITOR BPM 168B Contents Blood Pressure Monitor Intended Use What is blood pressure?

Measurement of body temperature: Instruments used to measure body temperature:

HRM Triax 100 is engineered to provide quick, one-touch access to a variety of critical information during training and in competition.

Dear HighQ Check System Owner :

Blood Pressure Monitor User Manual

CoaguChek S System. Quick Reference Guide. This is a CLIA-waived System. Coagulation Testing with Fresh Whole Blood

Welch Allyn Connex Vital Signs Monitor 6000 Power Supply Replacement

Glucose Meter. User Guide. Veterinary Monitoring System. For dog and cat use only

SARASOTA MEMORIAL HOSPITAL NURSING PROCEDURE. MEASURING BLOOD PRESSURE - MANUAL (equ04)

Data Collection Worksheet

Blood Glucose Monitoring System. User Guide

Chapter 1 Introduction

BP-600 Noninvasive Blood Pressure Sensor

Owner's Manual. Arm-type Fully Automatic Digital Blood Pressure Monitor. Arm Type. Model BSP-11

PedAlert 100. PedAlert 120

Management of Central Venous Access Devices. Blood Glucose Monitoring

The Progressa bed system

Items in the package:

Electrocardiography for Healthcare Professionals

Breezhaler. Open to see clear capsule. How do I use my Breezhaler? Care of my Breezhaler

Nord.cTracICA.Cr USER'S MANUAL A CAUTION QUESTIONS? .. Visit our website'at. new products, prizes, fitness tips, and much more!

LeadCare BLOOD LEAD ANALYZER. Quick Reference Guide

Evoke Massage Chair. User s Manual

GETTING STARTED WITH MINIMED 670G CONTINUOUS GLUCOSE MONITORING

LEARNING OUTCOME The students will be able to elicit vital signs correctly on human volunteers/patients

Adventure 3 Plus Service Manual

Fraser Health Authority Accu-chek Inform II: Training Script

Accu-Chek Inform II: Point of Care Glucose Testing. Sharp Healthcare 2014

QUICK START GUIDE TYMPANOMETRY AND AUDIOMETRY FOR SENTIERO DESKTOP DEVICES

HRM Triax 15 is engineered to provide quick, one-touch access to a variety of critical information during training and in competition.

User Instruction Manual. Read this User Instruction Manual carefully before you start testing.

User s Manual. Blood Glucose Meter

Adventure 4 Plus Service Manual

Epilepsy Sensor Transmitter

Appendix M: Device Technique

LIFEBOX TROUBLESHOOTING. Tips and hints

Blood glucose monitor. MediTouch 2

Rhino Clear Sprint Atomizer

LET OUR IMAGE ENHANCE YOUR IMAGE. Operating Instructions MedRx Video Portable OtoScope System

Welcome to the S410. Blood Pressure System. Instruction Manual

XTR5 Elliptical Cross Trainer

Precision ceedpro. Online Training for. Glucometer & Capillary Collection

GlucCell TM SYSTEM USER S GUIDE ver 2.3 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System

TABLE OF CONTENTS. 2.0 USING MANAGER PREFERENCE 2.1 Using manager preference mode 2.2 Selecting US or metric 2.3 Using CSafe

OWNER S MANUAL. BODYCRAFT 7699 Green Meadows Dr., Lewis Center, Ohio Tel:

CIRCUIT ZONE ELLIPTICAL

841T. Adventure4 Adventure5 TREADMILL OWNER S MANUAL

MEASURING AND RECORDING PATIENT VITAL SIGNS

Vital Signs Dr. Gary Mumaugh Western Physical Assessment

ENGLISH. USER MANUAL Register your product at: multi-action toothbrush

PLANK 1 Direct Care Staff Trained in Accurate BP Measurement

2. Before Testing Monitor Checker Test...10 Inserting Lancets into Lancing Device...11 Quality Control Testing...13

MDT2. Self-Monitoring Blood Glucose System. Quick Reference Guide

Blood Glucose & Ketone Monitoring System

CentriVet GK Blood Glucose & Ketone Monitoring System

TIP CARD. Model Temporary External Pacemaker

Activity Vital Signs: Heart Rate and Blood Pressure

GlucCell TM SYSTEM USER S GUIDE Ver 2.1 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System

Owner s Manual. Model# IMPORTANT: Read all instructions carefully before using this product. Retain this owner s manual for future reference.

Taking and recording blood pressure and pulse. City Gate Training Centre all rights reserved

Logic. Owner s Guide. Blood Glucose Monitor

Blood Glucose Monitoring System

Measuring and Recording Temperature

Adtemp TM Digital Ear Thermometer

PLUS One. Blood Glucose Monitoring System. Owner s Manual

Vital Signs. Dr. Gary Mumaugh Western Physical Assessment

User s Manual Blood Glucose Meter

BRS GM100 Glucose Monitoring System. User Instruction Manual Ver. 3.5

User s Manual Blood Glucose Meter

PROFESSIONAL CARE OXYJET air. powered. Downloaded from manuals search engine. filter. OxyJet

Chapter 12 - Vital_Signs_and_Monitoring_Devices

Bio-logic AuDX PRO FLEX Screening tympanometry and audiometry Quick start guide

Heart Rate, Blood Pressure, and Exercise. Evaluation copy

Vital Signs. 1. Define important words in this chapter. 2. Discuss the relationship of vital signs to health and well-being

TRANSCRIPT for Lantus SoloSTAR pen injection for your patients

Medications. Managing and Administering Medication

Adventure 5 Plus Service Manual

ESSENTIAL GUIDE. Companion Microphone. How-to videos on hihealthinnovations.com

Chapter 21. Assisting With Assessment. Elsevier items and derived items 2014, 2010 by Mosby, an imprint of Elsevier Inc. All rights reserved.

Physiological Measurements Training for Care/Nursing & LD Small Group Home Staff

Recharge. Relax.Repeat.

Monitoring Equipment. Blood Pressure Monitor Upper Arm Type: Image (Image not to scale)

SIX PACK ABS Item No INSTRUCTION MANUAL. Read entire manual before operating this product. Use only as directed.

WHOLE BODY VIBRATION THERAPY

BLOOD GLUCOSE MONITORING SYSTEM OWNER'S MANUAL

HealthCare International, Inc.

Transcription:

Vital Signs Monitor 52000 Series (VSM) Outline Train the Trainer A. Light Weight and Durable 1. Weighs approximately 6 pounds 2. Made of heavy plastic B. Battery 1. Sealed lead acid battery 6 V 2. Battery life provides approximately 10-12 hours of continuous monitoring of B/P, temperature and SpO 2. 3. The battery charges to 90% of capacity in 12 hours. 4. The VSM should be charging when not in use. Low Battery Warning 1. Battery indicator is located on front panel when the unit is turned on. 2. When battery is LOW, a warning tone sounds and the low battery indicator flashes. (To avoid shutdown, plug in and connect the AC power.) C. Transport Handle D. Start Up The VSM runs a self-check upon power up. (All LED segments in each display turn on briefly and an audible tone sounds.) VSM 5200 front panel functions: A. Power Button & Indicator Light B. Start Button C. Cancel Button D. Review Button E. Auto Button & Indicator F. Silence Button & Indicator G. Select Alarm Button H. Set Buttons (Arrow Up or Arrow Down) I. Pulse Tone Indicator J. Pulse Tone Button K. Systolic Display L. Diastolic Display M. SpO 2 Display N. Pulse Signal Bar Graph O. Pulse Display P. Temperature Display & Indicator Q. Cycle Display R. Charging Indicator S. Low Battery Indicator T. Memory Indicator 1

F. Intended Use The Welch Allyn VSM 5200 is intended to be used on adult and pediatric patients. Adult: 12 years and over Pediatric: 29 days to 12 years **NOTE** The Welch Allyn VSM 5200 is not designed to be used on Neonatal Patients. G. Limits 1. This feature allows you to make changes to the high and low alarm limits for the following vital signs. a. Systolic HIGH and Systolic LOW b. Diastolic HIGH and Diastolic LOW c. Pulse Rate HIGH and Pulse Rate LOW d. SpO2 LOW 2. To make changes to the limits: a. Press Select Alarm button b. For the selected vital: Press Set Buttons, Up/Down Arrows, as needed to change the limit or (---) to disable the alarm. c. The alarm parameter you are changing, such as HR HIGH, will be displayed in the appropriate display. d. Press Select Alarm Button to accept alarm limit and advance to next vital sign. e. To return to normal operation, do nothing for 10 seconds. 3. Silence Button and Indicator When an alarm sounds, pressing the Silence button will silence it for 30 seconds. You will see a flashing display to indicate the alarming parameter. H. NIBP 1. Before starting the NIBP measurement, always perform the steps described below: a. Select appropriate cuff. The cuff is the appropriate size when the artery index marker lies somewhere between the range markings on the NIBP cuff. b. Position the cuff. The cuff should always be positioned on a bare arm, midway between the shoulder and the elbow, with the artery index marker over the brachial artery. It should fit comfortably to allow no more than 1-2 fingers space between the cuff and the arm. During the NIBP measurement cycle, the patient should have no movement to the extremity and should remain quiet. NOTE: If the cuff is not level with the heart, there is a 1.8 mmhg drop to the systolic and diastolic pressures for every inch the arm is raised above the heart. For every inch the arm is lowered below the heart there is a 1.8 mmhg rise in the systolic and diastolic pressures. 2. Manual NIBP measurements a. Attach the appropriate cuff to the patient s arm. b. Press Start button c. When the B/P cycle is completed, a tone sounds and the NIBP results are displayed in the SYSTOLIC, DIASTOLIC and PULSE rate displays. d. The results are displayed for 2 minutes or until another NIBP cycle is initiated. 2

NOTE: If the SpO2 sensor is attached and generating valid pulse data, the displayed PULSE rate is derived from the SpO2 sensor reading. 3. Automatic NIBP Interval measurements a. Attach the appropriate cuff to the patient s arm. b. Press Auto button to set the measurement interval which includes: ST (Stat), 1, 3, 4, 5, 10, 15, 30, 45, 60 and 90 minutes. The three dashes (---) in the display indicate that the automatic mode for NIBP is turned OFF. c. Within ten seconds after you select an interval and assuming that safe venous return pressure has been maintained for at least 30 seconds, the monitor automatically starts the first automatic NIBP cycle. d. When the cycle ends, a tone sounds and the monitor displays the reading. The measurement will remain on the screen until the next measurement cycle begins, 2 minutes pass, or the Start button is pressed again. 4. ST/ STAT Measurement If the selected interval is STAT, the monitor takes repeated NIBP measurements for up to 15 minutes, starting a new cycle each time the cuff deflates below 10 mmhg. I. SpO2 Monitoring (if applicable) 1. Verify that the SpO2 sensor is connected to the monitor. 2. Attach the SpO 2 sensor to the patient s index finger. Do not attach the SpO 2 sensor to the same limb as B/P cuff. 3. Within a few seconds, the pulse signal bar graph reflects the strength and quality of the pulse. 4. Within approximately 10 seconds, the initial measurement is displayed and a numeric pulse rate value appears in the PULSE display. 5. SpO2/Pulse Tone Volume a. Press Pulse Tone button to control volume of SpO 2 pulse tone. b. The pulse tone can be adjusted to any of 5 volume settings from silent to high. c. To set the displayed new values, do nothing for 3 seconds. NOTE: Changing the volume of the pulse tone has no effect on the volume of alarm tones. J. Temperature Monitoring (if applicable) If configured with the temperature option, the monitor can obtain predictive or monitored temperature measurements. NOTE: Temperature range (Low--80'F and High--110'F) Predictive measurements: a one-time temperature reading which takes only a few seconds. Results are obtained in: Oral: approximately 4 seconds Axillary (ages less than 4 years): approximately 10 seconds Rectal: approximately 15 seconds Readings will be displayed as: F Fahrenheit or C Celsius. 3

Monitored measurements: continuous temperature monitoring used when the situation prevents an accurate predictive measurement. Results are obtained in: Oral: 3 minutes Axillary: 5 minutes Rectal: 3 minutes Readings will be displayed as: FM Fahrenheit Monitored or CM Celsius Monitored 1. Prep Thermometer Probe NOTE: Tip of Probe is preheated to 93'F a. Hold the probe collar with the blue ejection button with your thumb and forefinger and withdraw the probe from the probe holder. b. Wait for the OrL to appear in the temperature display. c. Insert the probe into a new probe cover and press down firmly until a new probe cover engages onto the probe. 2. Taking Oral Temperatures It is IMPORTANT while taking an Oral predictive temperature to: a. Instruct the patient not to talk or move during the temperature reading process. b. Place the probe deep into the patient s posterior sublingual pocket. c. Have the nurse hold the probe in place maintaining tissue contact until the temperature is complete. d. The predictive temperature reading will be displayed for 1 minute in the temperature display. e. Interferences with oral measurements for up to 20 minutes include: 1. Ingesting hot or cold liquids 2. Talking 3. Eating food 4. Chewing gum or mints 5. Brushing teeth 6. Mouth care 7. Smoking 8. Performing strenuous exercises 3. Taking Axillary Temperatures a. Hold the probe collar with your thumb and forefinger and withdraw the probe from the probe holder. b. Wait for the OrL to appear in the temperature display. c. Press the Set-Arrow Up button once to change the display to ALY. d. Insert the probe into a new probe cover and press down firmly until a new probe cover engages onto the probe. e. Lift the patient s arm to fully expose the axilla. Place the probe tip as high as possible in the axilla, aligning the probe vertically with the spine. Next, lower the patient s arm down to make maximum contact with the probe tip. The patient should always remain still, maintaining good tissue contact throughout the process. 4

f. The predictive temperature reading will be displayed for 1 minute in the temperature display. NOTE: Quick predictive axillary temperature readings are accurate only for children under the age of four years old. If an axillary reading is desired for a patient age four and older, the Blue probe must be used in Monitor Mode. 4. Taking Rectal Temperatures For rectal temperatures, use only the RECTAL PROBE with the RED ejection button. a. Hold the probe collar with your thumb and forefinger and withdraw the probe from the probe holder. b. Wait for the REC to appear in the temperature display. c. Load the probe cover onto the probe. d. Apply a thin coat of water-based lubricant to the tip of the probe cover (optional). e. Insert the probe tip 5/8 inch inside the rectal sphincter for adults and approximately ½ inch for children. f. Tilt the probe slightly to ensure good tissue contact. g. The predictive temperature reading will be displayed for 1 minute in the temperature display **WARNING** Use extreme care to avoid risk of bowel perforation. **NEVER** Reuse probe covers; reusing covers will give inaccurate temperature readings. 5. Taking Monitor Mode Temperatures a. Continuous monitoring mode is not recommended for use over 5 minutes. b. Measurements are not stored in memory. c. 3-5 minute thermometer reading is equivalent to using a glass thermometer. d. Useful for double-checking fast predictive readings; i.e. an infant exposed to cool ambient temperatures or hypothermic patient. e. To use Monitor Mode: 1. Select the correct probe and remove from probe holder. 2. Load probe cover and wait one minute; the Monitor will automatically switch to Monitor Mode. 3. Determine the site for the Temperature reading: Oral, Axillary, or Rectal 4. Take the patient s reading in appropriate site. Continue to hold the probe in position for the required duration: Oral 3 minutes Axillary 5 minutes Rectal 3 minutes 5

5. Record the temperature before removing the probe from the site. Monitor Mode temperatures are not stored in memory. 6. Discard the probe cover. Upon returning the probe to the holder, the thermometer will revert back to default mode. Change as needed. NOTE: The thermometer enters Monitor Mode automatically if the probe is removed from the holder and not used for 60 seconds or if the patient s temperature is too low to allow the device to predict a reading. K. Review Button 1. Press Review button to display most recent set of vital signs. 2. The Monitor stores 99 sets of data. 3. The data will appear in appropriate displays and the Cycle display will show total number of data sets currently in memory. L. Erasing Data 1. All patient vital sign data is erased when the Monitor is powered Off. a. To erase patient data during normal operation, press and hold the Cancel button for 3 seconds until a confirmatory beep is heard. M. Nurse Call (if applicable) When the cable is connected and operational, the Monitor immediately notifies the Nurse Call system when a patient alarm occurs. N. Error Codes 1. The VSM 5200 is equipped with the technology to detect an error when calculating a patient s vital sign. The codes will display on the parameter that has the error. 2. The error code references are located on the right side of the VSM 5200 and also in the VSM 5200 Operator s Manual. O. Cleaning 1. Wipe the Monitor with a damp cloth with one of the following: a. Warm water and a mild detergent b. Hospital disinfectant that is non-staining 2. Wipe the Temperature Probe with a damp cloth with one of the following: a. Alcohol b. Warm water c. Hospital disinfectant that is non-staining 3. Wipe the SpO2 Sensor with a damp cloth with one of the following: a. < 70% isopropyl Alcohol b. 10% or less Bleach Solution P. Replacing Printer Paper (if applicable) 1. Press Printer button to open the printer door. 2. Insert new roll of paper; use only WA thermal paper. 3. Thread end of roll over the roller and through slot in printer door. 4. Pull slightly on paper to take up any slack, then close printer door. 6