Dynamic Hollow Cylinder System Proposal

Similar documents
GDSTTS Ver.6.0 Release Notes Digital Transducer Interface

Universal Calibration Device for Pressure Transducer Calibration

RiGO801 Laboratory Requirements

DEFORMATION TRANSDUCER CALIBRATOR OPERATION

High Grade Universal Testing Machines

Data processing software for TGI/TGE series

Polymer Bonded Explosives XTX 8004 (80 wt% PETN-20 wt% PDMS)

Advanced in vitro exposure systems VITROCELL VC 10 S-TYPE SMOKING ROBOT

Advanced in vitro exposure systems

...vibration isolation. Mounts

NC DOUBLE OPPOSING HEAD DRILL

By: Stephanie Bendtsen, Joseph Calderan, and Celeste Dupont Team 17 Client: Dr. Sun

The ADL Force 5 configured for knee testing

CRITICAL STATE BEHAVIOR OF AN UNSATURATED SILTY SAND

With extended functionality the sensors are also applicable for the detection of air bubbles.

SpiderX. Portable Residual Stress X-Ray Diffractometer.

10 Years Experience in Industrial Phased Array Testing of Rolled Bars

USER MANUAL, VOL.2.0 T I S S U E P U L L E R T P

NCHRP 9-30A CALIBRATION OF RUTTING MODELS FOR HMA STRUCTURAL AND MIXTURE DESIGN APPENDIX I SIMPLE PERFORMANCE TEST SYSTEM INSTRUMENTATION

SURETEST Torque Calibration System

Technical Data Sheet SONOFLOW CO.55/xxx(H) V2.0

w. D. Jolly, F. A. Bruton, and C. Fedor

Advanced in vitro exposure systems VITROCELL VC 1 SMOKING MACHINE

Digital Dentistry Solution

E200 ORT - Optical Rotary Torque Transducer. Contents

COMPARISON BETWEEN THE CONTINUOUS AND STEP BY STEP CALIBRATION METHODS OF FORCE TRANSDUCERS

CAD/CAM TECHNOLOGY. DC7 Milling System

SURETEST Torque Calibration System

Technical Data Sheet SONOFLOW CO.55 V1.0

microprocessor controlled eddy current brake Load / accuracy Watt, speed independent / according to DIN VDE

XRAY Series Includes

Angular Measurements with BIOPAC Goniometers & Torsiometers

Description The 4000 Series offers up to 8600 in-lb of torque and 25 gpm (continuous ratings). This is the corner stone of the Char-Lynn line.

HiFFUT A New Class of Transducer

Challenges of High Speed Splicing

Solar Illumination Study

mardtb Goniostat for X-ray crystallography

Lexium 05 motion control

V New HGP 20. Standard grippers 7.5. Economical and versatile. Self centring. Choice of gripping action. Standard grippers.

Hemodynamic Analysis System

ECG MACHINE KEC- Series

TRANSFORMER ALL IN ONE ISOKINETIC MACHINE ANKLE ELBOW HIP SHOULDER WRIST TRUNK

Exercise 6: Muscle Physiology II Twitch & Summation

PROFIBUS Products Overview P PROFIBUS Converter/Repeater P PROFIBUS Gateway P6-3-1

Detection. at first sight. One of the newest trends

OTAGO LIPOSURG. Compact, powerful system for infiltration and liposuction

Lexium 05 Servo Drives. Motion control The high concentrate solution for your machines

Dosimeter Setting Device System NRZ

Evolution of ultrasonic inspection techniques on railway axles. 2. RDG 3000F PA, the new frontier of solid axles inspection

The design and development of a force comparator standard machine to provide national traceability in force measurement to industry.

4-20 ma Pressure Transducer

Numerical analysis of the embedded abutments of integral bridges

Hitachi Aloka Medical manufactured one of the world s first diagnostic ultrasound platforms, and today this imaging modality has become the first

SMART EquiTest. Physical Dimensions. Electrical Characteristics. Components. Performance Characteristics. Accessories Included

APPENDIX H. Limit Equilibrium Analysis of Dike 1 Abutments Prior to Failure

N4i Installation Manual. (picture of N4i screen)

Description The 4000 Series offers up to 8600 in-lb of torque and 25 gpm (continuous ratings). This is the corner stone of the Char-Lynn line.

AUDIOLAB Two channel clinical audiometer. Tonal Audiometry Vocal Audiometry MASKING SISI ABLB Decay Test BEKESY

HDiag 37 - Vascular Assist 03 27/4/07 17:11 Page 1. Vascular Assessment Systems and Electronic Patient Record Software. DIAGNOSTIC Products Division

FT-302 Force Transducer

Defining Cutting Edge Quality. Laser Cutting Head BIMO-FSC BIMO-FSC

SINCE 1978 MADE IN THE USA PRO 7000 SERIES SUPPLEMENTARY MACHINES MEDICAL SERIES. engineered for success

Experiment HH-3: Exercise, the Electrocardiogram, and Peripheral Circulation

Hand of Hope. For hand rehabilitation. Member of Vincent Medical Holdings Limited

CORESTA RECOMMENDED METHOD N 22

Installation of force transducers

ECHOLAB. Screening and Clinical Modality. User Programmable Protocols. Otoacoustic Emissions System TEOAE - DPOAE - ABR - AABR

Case Study. Complex Components Demand Innovative Ultrasound Solution

Digital Dentistry Solution

ENT CHAIR OP-S10 / OP-S14 DESIGNED BY ENT SPECIALISTS FOR ENT SPECIALISTS. Completely motorized Ergonomic Robust

THYROID UPTAKE SYSTEMS

COMPLEX SEATING SPECIALISTS

Defining Cutting Edge Quality. Laser Cutting Head BIMO-FSC

EHA Physiology: Challenges and Solutions Lab 1 Heart Rate Response to Baroreceptor Feedback

BC380. The New Standard in Body Composition Analysis BODY COMPOSITION ANALYZER

Design & manufacturing a computerized Multi-Channel Isometric Dynamometer

RibFix Blu. Thoracic Fixation System

NOVIN medical engineering Co. Designer and manufacturer of physiotherapy equipment

RLS/E-EV MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES

Acceptance testing of a large aperture dynamic wavefront sensor

(12) Patent Application Publication (10) Pub. No.: US 2003/ A1. Giannelli (43) Pub. Date: Sep. 4, 2003

SIMULATOR FOR TESTING THE FRICTION TORQUE OF THE FEMORAL HEAD OF A HIP PROSTHESIS

experiences that matter

Traction. Process of drawing or pulling apart. May involve distraction and gliding. Pulling 2 articulating surfaces away from each other

Balance-Coordination-System

ESWL Based on Experience + Innovation

NOVA SELECTORIZED SINGLE AND DUAL STATIONS

TWO CHANNEL CLINICAL AUDIOMETER AUDIOSTAR PRO

Efficient Measurement of Large Light Source Near-field Color and Luminance Distributions for Optical Design and Simulation

Gastroesophageal reflux disease intervention testbed

Assessing potential cracking zones in embankment dams

Smart NDT Tools: A New Generation of NDT Devices

RLS /M MX SERIES

Evaluation of the Quality of Thick Fibre Composites Using Immersion and Air- Coupled Ultrasonic Techniques

Defining Cutting Edge Quality. Laser Cutting Head BIMO-FSC BIMO-FSC

aks bed concepts for the day-to-day nursing routine for homecare and in-patient applications

Ultrasonic Instruments for Non-Destructive Testing

METHOD AND DEVICE FOR ISOKINETIC QUADRICEPS EXERCISE USING PNEUMATIC MUSCLE ACTUATOR (PMA) RESISTANCE: COMPARISON TO FREE WEIGHT EXERCISE

Transcription:

Dynamic Hollow Cylinder System Proposal from Wykeham Farrance Limited Weston Road Slough SL1 4HW England Tel:+44 (0)1753 571241 Fax: +44 (0)1753 811313 E-mail: sales@wfi.co.uk

Advanced Soils Testing 2 Quality Innovation Expertise Wykeham Farrance Limited (WF) Established in 1940 WF have manufactured testing equipment for the commercial and educational field of geotechnical engineering. Hollow Cylinder WF has a long standing international reputation for excellent design and quality. WF in house knowledge, innovation and quality make us the No1 supplier of geotechnical products world wide. Cyclic Simple Shear Two axis control giving constant volume, constant height in shear with control of frequency and wave shape. Four axis control giving magnitude, direction, waveshape and frequency of the major and minor principle stresses. Cyclic Triaxial Three axis control of axial, radial and back pressure with control of magnitude, frequency and wave shape. DataMan Logger 16 Channel high speed logger. 10 readings per second. Blue tooth communication, stand alone or PC control. Software for test setup, calibration and test recording. Bender Elements Suction Transducer Triaxial cells recognised throughout the world, original design features maintained. Standard, Advanced and Unsaturated ranges. Sample size 35-150mm diameter. Pressure ranges up to 3400kPa

Quality Innovation Expertise Apparatus Advanced Soils Testing 3 The Wykeham Farrance Apparatus allows the investigation of the rotation of principle stress within the soil sample. It does this by independently controlling the direction and magnitude of the three principle stresses in Consolidation, Monotonic and Cyclic Shear. The WF system is computer controlled with five control channels and up to sixteen data acquisition channels. Simultaneous 4 axis control Anisotropy of soil samples Effects of principal stress rotation Effects of intermediate principal stress Base Frame The hollow cylinder cell is mounted on a base frame which gives excellent rigidity for axial and radial loading of the sample. The base frame also supports the axial and torsional actuators, control and data acquisition system, air water interfaces and volume change. the cell top is positioned. Triaxial Cell 150mm triaxial cell for 100mm outside diameter and 60mm inside diameter x 200mm long samples. The cell has an internal frame which holds the load/torque transducer. All the fill, empty and drainage ports from the top cap and base pedestal are positioned in the triaxial cell base. All internal transducer cables exit through the base. This allows the sample to be accurately set up, with all transducers placed, before Axial Actuator The axial double acting pneumatic actuator is mounted on the base of the triaxial cell ensuring good alignment. It is fitted with a digital servo valve which controls the force displacement frequency and wave shape.the actuator can apply an axial load of +/- 10kN, with a stroke of +/- 25mm. Inner Cell Pressure The inner cell pressure is applied through digitally controlled air valves in closed loop with the cell pressure transducer. Outer Cell Pressure The outer cell pressure is applied through digitally controlled air valves in closed loop with the outer cell pressure transducer. Back Pressure Back Pressure is applied through digitally controlled air valves in closed loop with the back pressure transducer. Frequencies up to 1 Hz on simultaneous 4 axis control which is essential for applying magnitude and direction of the major and minor principle stresses. Torsional Actuator The torsional double acting pneumatic actuator is mounted on a platform in the base frame. It is fitted with a digital servo valve which controls the force displacement frequency and wave shape. The actuator can apply a torsional force of +/-200Nm, with 90 degrees of rotation.

Advanced Soils Testing 4 Quality Innovation Expertise Computer Control and Data Acquisition System (CDAS) The CDAS is a compact self contained unit that provides all critical control, timing and data acquisition functions for the test and the transducers. The CDAS and computer communicate through a standard RS232 C serial interface or high speed USB interface at 10Hb/s. Software The software sections the test into five stages 1 General This is where you enter:- Operator Sample Identification Dimensions Initial inner sample diameter Initial outer sample diameter Initial sample height File name 2 Saturation Inner/Outer pressure increment (stepped or continuous) Back pressure differential Target time The data acquisition module has sixteen normalised (+/- 10v range) transducer input channels. These channels are digitised by accurate, high speed 20 bit analogue to digital (A/D) converters for data analysis and presentation. The control module has five channels for feedback control. Two are dedicated to the actuators for vertical stress and torsional stress and three are dedicated to the servo control valves for inner and outer cell pressures and back pressure. Supervised by the PC, the CDAS automatically controls the operation of loading for individual types of test. The CDAS directly controls the servo valve to apply the requested loading rate or waveform, cell pressure and back pressure.while the specimen is being subjected to loading forces, the CDAS captures data from the transducers and transfers these, via an RS232 serial or USB link, to the PC for processing, display and storage. 3 Consolidation Three types of consolidation are offered Isotropic Consolidation Initial mean normal stress Target mean normal stress Target time Anisotropic consolidation -Type A Initial mean normal effective stress Target axial stress Earth pressure coefficient Intermediate principal stress coefficient Target time Anisotropic consolidation -Type B Initial mean normal effective stress Target mean normal effective stress Target deviator stress Initial major principal stress direction Target major principal stress direction Initial intermediate principal stress coefficient Target intermediate principal stress coefficient Target time

Quality Innovation Expertise Advanced Soils Testing 5 4 Monotonic shear (Stress control) Drainage condition: Drained or Undrained Intermediate principal stress coefficient during shear Monotonic shear direction Isotropically consolidated Major principal stress direction Anisotropically consolidated Induced deviator stress direction Loading rate of induced deviator stress Termination octahedral shear strain 5 Cyclic shear Drainage condition: Drained or Undrained Intermediate principal stress coefficient dur shear: Cyclic shear direction Isotropically consolidated Major principal stress direction Anisotropically consolidated Induced deviator stress direction Induced cyclic deviator stress (Asymmetric cyclic loading is possible) forward from the starting point: backward from the starting point Frequency Termination octahedral shear strain Termination number of cycles

Advanced Soils Testing 6 Quality Innovation Expertise Transducers digital servo valve for control of the cell pressure. The 1000kPa pressure will have a resolution of 0.05kPa Load Torque Transducer +/-9kN, +/- 200Nm submersible transducer. The transducer is fitted to the internal frame of the triaxial cell. The reaction of the applied forces is transmitted through the internal triaxial cell frame into the base frame it measures the load and torque applied to the sample independently. The 9kN axial load has a resolution of 0.3N The 200Nm torque has a resolution of 0.01Nm. Outer Cell Pressure Transducer 1000kPa cell pressure transducer is mounted close to the triaxial cell base, it is in a closed loop with the digital servo valve for control of the inner cell pressure. The 1000kPa pressure will have a resolution of 0.05kPa Pore Water Pressure Transducer 1000kPa pore pressure transducer mounted close to the triaxial cell base. The 1000kPa pressure will have a resolution of 0.05kPa Radial Displacement Transducer +/-50mm travel displacement transducer. This transducer is mounted on the radial torque actuator. It has a dual purpose of being the part of the closed loop system for controlling the position of the actuator and monitoring the radial movement or rotation of the sample. The +/-50mm travel will have a resolution of 1.5micron or 5sec of arc. Axial Displacement Transducer +/- 25mm displacement transducer mounted on the axial actuator It has a dual purpose of being the part of the closed loop system for controlling the position of the actuator and monitoring the axial movement of the sample. The +/-25mm travel will have a resolution of 1.5micron Sample Volume Change Transducer 100cc volume change transducer mounted on a shelf in the base frame, it monitors the sample volume change. This volume change value is used with the inner cell volume change and the radial strain transducer to calculate the sample volume change and outer diameter. 100cc volume change will have a resolution of 0.005cc Inner Cell Volume Change Transducer 100cc volume change transducer mounted on a shelf in the base frame, it monitors the inner cell volume change. This volume change value is used to calculate the sample inner diameter. 100cc volume change will have a resolution of 0.005cc All transducers are fitted with an in line calibration module Inner Cell Pressure Transducer 1000kPa cell pressure transducer is mounted close to the triaxial cell base; it is in a closed loop with the

Quality Innovation Expertise which normalizes all the transducer outputs. This means that transducers can be changed or moved without the need to recalibrate. Transducer, stores all transducer calibration data, serial numbers reallocating a transducer is just a stroke on the keyboard. Wave Shape, stores all wave shapes standard and user defined. Advanced Soils Testing Top Cap and Base Pedestal Set. Special top cap and base pedestal set 100mm with 60mm inside diameter. Both are designed to accept the special internal membranes. Porous discs with fins are fixed to the top cap and base pedestal for gripping the sample when the rotational stresses are applied. Both are supplied with two ports for drainage and pore water pressure. 7 Test, stores all test set up data.tests can be reproduced at any time with the same routine as previously used. Universal Tuning Program, allows you to tune the system to obtain the best wave shape. Hardware The hollow cylinder cell is mounted on a base frame which provides the support and reaction to all the applied stresses to the sample. It also houses the vertical and torque actuators, air water interfaces, the control and data acquisition system, the auxiliary air cylinder on which is mounted the control valves for the inner, outer and back pressures. All transducers except the load /torque transducer are positioned in the base frame. Base Pedestal Sample Preparation Equipment This kit comprises of the following: A motorised soil lathe to allow an extruded or a block sample to be machined to 100mm diameter.the motorized soil lathe has a drilling attachment which will allow a 60mm diameter hole to be drilled in stages. A three part split former is supplied to allow trimming of the sample ends and allow sample movement without damage. A set of internal and external moulds for preparing unbound samples. The external mould is a three part mould which sits on the triaxial cell base. It has a vacuum connection to suck the membrane onto the inner wall of the mould. Essential when preparing low density samples. The inner mould is in segments to allow it to contract and be withdrawn after the sample has been prepared Optional Accessories Radial and Strain Transducers. +/- 2.5mm strain transducers which are mounted on the sample. Measures the change in sample height / diameter over the middle third of the sample. Resolution of 0.1 micron. High Air Entry Top Cap and Base Pedestal Set special set with the pedestals fitted with high air entry stones for testing partially saturated or unsaturated samples. De-aired Water System. Gravity fed supply of de-aired water to the inside and outside of the hollow cylinder sample. Compressed Air System. Minimum 800kPa working pressure.

Advanced Soils Testing 8 Quality Innovation Expertise Sample Dimensions 1. Sample Dimensions H sample height (mm) D i sample inner diameter (mm) r i sample inner radius (mm) l i radial movement of inner wall (mm) D o sample outer diameter (mm) r o sample outer radius (mm) l o radial movement of outer wall (mm) 2. Applied Force and Pressures W T P i P o applied axial load (N) applied torque (N m) confining inner cell pressure (kpa) confining outer cell pressure (kpa) 3. Applied Stresses σ a axial (vertical) stress σ r radial stress σ h horizontal (circumferential) stress τ ah shear stress Ordering Information Apparatus for 200mm high samples, 100mm OD and 60mm ID. With 20 bit closed loop Control and Data Acquisition system to apply axial and radial stresses up to 9kN, 200Nm at 1Hz 240V 50Hz 1ph As avove but 110V 60Hz 1ph Sample preparation Kit for Hollow Cylinder to produce samples 60mm ID x 100mm OD. 240V 50Hz 1ph As above but 110V 60Hz 1ph Air compressor 10 Bar max working pressure. 240V 50Hz 1ph As above but 110V 60Hz 1ph Panel mounted de-airing tank Valve panel for use with de-airing tank Vacuum pump. 240V 50Hz 1ph As above but 110V 60Hz 1ph 12440 12441 12445 12447 12100 12101 11670 11680 33312 33314