Research Article A New Coated Nitinol Occluder for Transcatheter Closure of Ventricular Septal Defects in a Canine Model

Similar documents
Percutaneous VSD closure

Jian Fang 1, Shaobo Xie 2, Lunchao Ma 2, Chao Yang 2. Original Article

Risk Factors and Outcomes of Post-Procedure Heart Blocks After Transcatheter Device Closure of Perimembranous Ventricular Septal Defect

Comed Clinical Information Hyperion Occluders & Vascular Plugs

Perimembranous ventricular septal defects (pmvsds) are

For Personal Use. Copyright HMP 2013

Percutaneous VSD closure: Problems in the mid- and long-term

Hybrid Muscular VSD Closure in Small Weight Children

Type Size AP/PS RP/RS Qp/Qs. Ia Resistive <0.3 < Ib Resistive <0.3 < IIa Resistive <0.5 >2

Eighteen-month outcome of pulmonary valve stent implantation by direct right ventricle puncture: An animal study

Percutaneous atrial septal defect closure with the Occlutech Figulla Flex ASD Occluder.

Department of Internal Medicine, Saitama Citizens Medical Center, Saitama , Japan

Tom Eisele, Benedikt M. Muenz, and Grigorios Korosoglou. Department of Cardiology & Vascular Medicine, GRN Hospital Weinheim, Weinheim, Germany

Efficacy and Safety of Using Amplatzer Ductal Occluder for Transcatheter Closure of Perimembranous Ventricular Septal Defect in Pediatrics

CONGENITAL HEART DEFECTS IN ADULTS

Case Report Internal Jugular Vein Thrombosis in Isolated Tuberculous Cervical Lymphadenopathy

Case Report Coronary Artery Perforation and Regrowth of a Side Branch Occluded by a Polytetrafluoroethylene-Covered Stent Implantation

Case Report Sinus Venosus Atrial Septal Defect as a Cause of Palpitations and Dyspnea in an Adult: A Diagnostic Imaging Challenge

LAmbre LAA Occluder Updates

Percutaneous Device Closure of Congenital VSDs Current techniques and results for treating ventricular septal defects.

Follow-up after VSD closure- what to look for?

Case Report Successful Treatment of Double-Orifice Mitral Stenosis with Percutaneous Balloon Mitral Commissurotomy

Early and Late Complications Associated With Transcatheter Occlusion of Secundum Atrial Septal Defect

Case Report Asymptomatic Pulmonary Vein Stenosis: Hemodynamic Adaptation and Successful Ablation

Case Report Computed Tomography Angiography Successfully Used to Diagnose Postoperative Systemic-Pulmonary Artery Shunt Narrowing

Patient Information. Atrial Septal Defect (ASD) Repair

Case Report Formation of a Tunnel under the Major Hepatic Vein Mouths during Removal of IVC Tumor Thrombus

Case Report Successful Implantation of a Coronary Stent Graft in a Peripheral Vessel

Case Report Double-Layered Lateral Meniscus in an 8-Year-Old Child: Report of a Rare Case

Percutaneous occluder device closure through femoral vein guidance by transthoracic echocardiography in adult atrial septal defect patients

Patient guide: pfm Nit-Occlud PDA coil occlusion system. Catheter occlusion of. Patent Ductus Arteriosus. with the

Conference Paper Oncothermia Basic Research at In Vivo Level: The First Results in Japan

Perventricular Closure of Muscular VSD

Case Report Osteolysis of the Greater Trochanter Caused by a Foreign Body Granuloma Associated with the Ethibond Suture after Total Hip Arthroplasty

Conference Paper Antithrombotic Therapy in Patients with Acute Coronary Syndromes: Biological Markers and Personalized Medicine

ΔΙΑΧΕΙΡΙΣΗ ΑΣΘΕΝΩΝ ΜΕ ΜΕΣΟΚΟΛΠΙΚΗ ΕΠΙΚΟΙΝΩΝΙΑ ΖΑΧΑΡΑΚΗ ΑΓΓΕΛΙΚΗ ΚΑΡΔΙΟΛΟΓΟΣ ΗΡΑΚΛΕΙΟ - ΚΡΗΤΗ

National Imaging Associates, Inc. Clinical guidelines CARDIAC CATHETERIZATION -LEFT HEART CATHETERIZATION. Original Date: October 2015 Page 1 of 5

Clinical Study The Value of Programmable Shunt Valves for the Management of Subdural Collections in Patients with Hydrocephalus

Percutaneous reimplantation of a pulmonary valved stent in sheep: A potential treatment for bioprosthetic valve degeneration

Transcatheter closure of patent foramen ovale using the internal jugular venous approach

Transcatheter Closure of Acute Myocardial Infarction VSD

For Personal Use. Copyright HMP 2013

Device closure of congenital ventricular septal defects with Amplatzer devices: first experiences in Turkey

Original Policy Date

Muscular VSD Occluder

Case Report Late Type 3b Endoleak with an Endurant Endograft

IMAGES. in PAEDIATRIC CARDIOLOGY

Adult Echocardiography Examination Content Outline

Baris Beytullah Koc, 1 Martijn Schotanus, 1 Bob Jong, 2 and Pieter Tilman Introduction. 2. Case Presentation

Research Article Reduction of Pain and Edema of the Legs by Walking Wearing Elastic Stockings

Journal of the American College of Cardiology Vol. 33, No. 5, by the American College of Cardiology ISSN /99/$20.

Case Report A Rare Case of Complete Stent Fracture, Coronary Arterial Transection, and Pseudoaneurysm Formation Induced by Repeated Stenting

Case Report Intracranial Capillary Hemangioma in the Posterior Fossa of an Adult Male

Case Report Anomalous Left Main Coronary Artery: Case Series of Different Courses and Literature Review

Case Report Hemostasis of Left Atrial Appendage Bleed With Lariat Device

Transcatheter Atrial Septal Defect Closure with Right Aortic Arch Is it really difficult? M Tokue, H Hara, K Sugi, M Nakamura

Anaesthesia for percutaneous closure of atrial septal defects Patrick A Calvert BCh MA MRCP Andrew A Klein MBBS FRCA

Case Report Optic Disk Pit with Sudden Central Visual Field Scotoma

Index. interventional.theclinics.com. Note: Page numbers of article titles are in boldface type.

Transcatheter closure of the patent ductus arteriosus using the new Amplatzer duct occluder: Initial clinical applications in children

Case Report Reverse Segond Fracture Associated with Anteromedial Tibial Rim and Tibial Attachment of Anterior Cruciate Ligament Avulsion Fractures

Paediatrica Indonesiana

LONG TERM COMPLICATIONS FOLLOWING PERCUTANEOUS ASD CLOSURE

Research Article Abdominal Aortic Aneurysms and Coronary Artery Disease in a Small Country with High Cardiovascular Burden

Diversion of the inferior vena cava following repair of atrial septal defect causing hypoxemia

Transcatheter closure of ventricular septal defects with nitinol wire occluders of type patent ductus arteriosus

Device Closure of ASD in Children Using the Amplatzer Devices: Indications and catheter preparations, technique, and outcome [15]

Eisuke Nomura, Hisatada Hiraoka, and Hiroya Sakai. 1. Introduction. 2. Case Report

Percutaneous closure of large VSD using a home-made fenestrated atrial septal occluder in 18-year-old with pulmonary hypertension

2. Case Report. 1. Introduction

Case Report Bilateral Distal Femoral Nailing in a Rare Symmetrical Periprosthetic Knee Fracture

Transcatheter Closure Versus Repeat Surgery for the Treatment of Postoperative Left-to-Right Shunts: A Single Center 15-Year Experience

AMPLATZER Septal Occluder

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully

Case Report An Undescribed Monteggia Type 3 Equivalent Lesion: Lateral Dislocation of Radial Head with Both-Bone Forearm Fracture

Glenmark Cardiac Centre Mumbai, India

Fermeture percutanée des CIA : matériels disponibles et résultats. Transcatheter closure of ASD : devices and results

Case Report PET/CT Imaging in Oncology: Exceptions That Prove the Rule

Atrial Septal Defect Closure. Stephen Brecker Director, Cardiac Catheterisation Labs

Case Report Intra-Articular Entrapment of the Medial Epicondyle following a Traumatic Fracture Dislocation of the Elbow in an Adult

CP STENT. Large Diameter, Balloon Expandable Stent

Atrial septal defects (ASDs) are one of the most

Case Report Müllerian Remnant Cyst as a Cause of Acute Abdomen in a Female Patient with Müllerian Agenesis: Radiologic and Pathologic Findings

Peter I. Kalmar, 1 Peter Oberwalder, 2 Peter Schedlbauer, 1 Jürgen Steiner, 1 and Rupert H. Portugaller Introduction. 2.

Devendra V. Kulkarni, Rahul G. Hegde, Ankit Balani, and Anagha R. Joshi. 2. Case Report. 1. Introduction

Closing your atrial septal defect without surgery

Use of a novel valve stent for transcatheter pulmonary valve replacement: An animal study

Research Article Relationship between Pain and Medial Meniscal Extrusion in Knee Osteoarthritis

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER

Transthoracic closure of atrial septal defect and ventricular septal defect without cardiopulmonary bypass

Transcatheter device occlusion of patent ductus arteriosus

PFO (Patent Foramen Ovale): Smoking Gun or an Innocent Bystander?

Intracardiac echocardiography: an ideal guiding tool for device closure of interatrial communications

REBEL. Platinum Chromium Coronary Stent System. Patient Information Guide

Peripheral and Cardiology Coder 2018

Transcatheter Aortic Valve Implantation Procedure (TAVI)

CY2015 Hospital Outpatient: Endovascular Procedure APCs and Complexity Adjustments

Research Article Comparison of Colour Duplex Ultrasound with Computed Tomography to Measure the Maximum Abdominal Aortic Aneurysmal Diameter

University of Wisconsin - Madison Cardiovascular Medicine Fellowship Program UW CICU Rotation Goals and Objectives

Transcription:

BioMed Research International Volume 2013, Article ID 507919, 7 pages http://dx.doi.org/10.1155/2013/507919 Research Article A New Coated Nitinol Occluder for Transcatheter Closure of Ventricular Septal Defects in a Canine Model Yong Zhou, 1,2 Feng Chen, 2 Xinmiao Huang, 2 Xianxian Zhao, 2 Hong Wu, 2 Yuan Bai, 2 and Yongwen Qin 2 1 Department of Cardiology, The No. 411 Hospital of People s Liberation Army, Shanghai 200081, China 2 Department of Cardiology, Changhai Hospital, Second Military Medical University, Shanghai 200433, China Correspondence should be addressed to Yongwen Qin; fibrillation@163.com Received 25 June 2013; Accepted 29 July 2013 Academic Editor: George E. Plopper Copyright 2013 Yong Zhou et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Aims. This study evaluated feasibility and safety of implanting the polyester-coated nitinol ventricular septal defect occluder (pcvsdo) in the canine model. Methods and Results. VSD models were successfully established by transseptal ventricular septal puncture via the right jugular vein in 15 out of 18 canines. Two types of VSDOs were implanted, either with pcvsdos (n =8) as the new type occluder group or with the commercial ventricular septal defect occluders (VSDOs, n = 7, Shanghai Sharp Memory Alloy Co. Ltd.) as the control group. Sheath size was 10 French (10 Fr) in two groups. Then the general state of the canines was observed after implantation. ECG and TTE were performed, respectively, at 7, 30, 90 days of follow-up. The canines were sacrificed at these time points for pathological and scanning electron microscopy examination. The devices were successfully implanted in all 15 canines and were retrievable and repositionable. There was no thrombus formation on the device or occurrence of complete heart block. The pcvsdo surface implanted at day 7 was already covered with neotissue by gross examination, and it completed endothelialization at day 30, while the commercial VSDO was covered with the neotissue in 30th day and the complete endothelialization in 90th day. Conclusion. ThestudyshowsthatpcVSDOisfeasibleandsafetoclosecanineVSDmodelandhas good biocompatibility and shorter time of endothelialization. 1. Introduction Over the past ten years, transcatheter closure of VSD has been widely used in China [1 3]. However, the most serious and unpredictable complication is still postprocedural atrioventricular block (AVB). With early clinical experience of AmplatzerVSDO,AVBoccurredatarateofupto3 8%with 3.8% requiring the placement of permanent pacemaker [4 6]. Although the postprocedural AVB incident rate is lower when using our domestic compared with using Amplatzer VSDO, we still cannot avoid its occurrence [1 3]. We believe the root cause could be the occluder itself. At present, the nitinol occlude is still woven by bare nitinol wire. This may cause three issues: (1) the hard nitinol wire and local tissues have direct contact, extrusion, and friction, which may result in the myocardium and conducting system damage, reducing postprocedural AVB [4 6]; (2) the Dacron fibers are sutured in VSDO, resulting in high speed flow of red cells through the slit and hit the right ventricle side of nickel wire, then occurring hemolysis [7, 8]; (3) the alloy surface is very smooth, not easy to endothelium; thus it increases the risk of thrombosis on occluder surface at early stage [9, 10]. After reviewing the defects of existing occluder, we produced the pcvsdo. In order to reduce the incidence of atrioventricular conduction system injury, embolism, and other complications, we coated surface of the VSDO with polyester clothing, which can prevent hard alloy wire from direct contact with soft myocardial tissue. To estimate the feasibility, safety, and effectiveness and provide experimental basis for clinical application, we used the animals implanted to evaluate the performance of this new type of ventricular septal occluder, while using the commercial occluder as control group.

2 BioMed Research International (a) (b) (c) Figure 1: (a) through (d) show the profile of pcvsdo: waist length and diameter 7 mm and 8 mm, right and left rim 12.5 mm. The pcvsdo is wearing polyester clothes of the commercial occluder. (d) 2. Methods 2.1. The PcVSDO. The occluder is made from Shanghai the Shape Memory Alloy Company (SHSMA Company), with waist length, waist diameter, and discs diameter at 7 mm, 8 mm, and 12 mm, respectively. It is covered with the medical 4-0 polyester thread warp knitted coat, both ends were suturedintherivetandcutbyhotknifetomakepolyester ingredients solidification and to prevent loose strand (Figure1). Before animal experiments, we designed some tests to compare the performance of the pcvsdo (pcvsdo group) and commercial VSDOs (commercial occluder group).weconcludedthat(1)thediametersofpcvsdos rims are larger than those of commercial VSDOs by 0.5 mm. pcvsdos require a minimum of 10 Fr sheath to delivery while the commercial VSD occluder requires 8 Fr sheath. (2) The tension of occluders in these two groups has no statistically significant difference in the deformation process of 1.25, 2.5, 3.75, 5, 6.25, 7.5, 8.75, 10, 11.25, 12.5, 13.75, and 15 mm. (3) The pcvsdos showed no obvious wear and tear by eyes, and the surfaces not significant difference by stereomicroscope before and after the release-withdrawal 50 times. (4) There were no tiny desquamations after releasewithdrawal 50 times in saline by observed lowest centrifugal liquid in both groups by stereomicroscope. No significant difference was observed in various physical parameters in these two groups. So the pcvsdos can be safe to implant in animals. 2.2. Implantation of the VSD Occluders. Total of 15 commercial VSDOs occluders were randomly divided into two groups: the new type occluder group with 8 and the control groupwith7.thenewtypeoccludergroup,vsdos,wasproduced into pcvsdos. Two groups of occluder was implanted in a canine animal model in vivo. The VSD canine models were established as described in the previous literature [11]. Briefly, the canines were anesthetized with intravenous ketamine (8 mg/kg) and diazepam (0.8 mg/kg). Electrocardiogram (ECG) and blood pressure monitored by femoral artery puncture were performed. If there is restlessness in canine, propofol (1 mg/kg) was further intravenously injected. Femoral vein puncture was performed for catheter access. The devices were implanted during the same procedure of VSD creation, using 10 Fr sheaths through the VSD into the left ventricle, and pcvsdos andcommercialvsdosareusedtoclosethevsdmodels. Immediate left ventriculograms were conducted to check the position of the device and to quantify any residual shunt. All procedures performed on canines were approved by the Ethics Committee of Changhai Hospital (Approval Reference

BioMed Research International 3 (a) (b) (c) Figure 2: Gross examination of tissues around the device: (a) and (b) show the pcvsdo surface covered a slice of intact thicken membrane at 7 days after closure of defect. No dislocation, thrombus formation, and device fracture were observed. (c) shows the surface and surrounding of the commercial occluder presented a large number of neotissue, while (d) shows the tissue was significantly reduced compared to the commercial occluder. (d) No. CH 20110234) and carried out in accordance with the relevant Chinese laws. 2.3. Follow-Up after Device Implantation. The canines were fed routinely and administered intramuscular injection of penicillin (800,000 u) daily (twice a day) for 3 days, low molecular heparin 1000 u injection twice a day. The canines were fed with aspirin 3 mg/kg daily in the following time points until they were sacrificed. Observation was done for the dietary intake, the mental state, and the performing situation of the canines, such as with or without blood in the stool, whether the urine color changed, and with or without abnormal behavior or hemiplegia. On days 7 and 30 after intervention, ECGs and TTE checks were repeated. At the time point of days 7, 30, and 90, the canines were anesthetized by the method described above and then sacrificed. The device, together with the surrounding tissues, was explanted, cleaned, and subjected to gross inspection, pathologic and scanning electron microscope examination. 3. Results In a total of 18 canines, 2 appeared pericardial tamponade, 1 had complete atrioventricular block and died during puncture ventricular septal, and 15 cases were successfully modeling, of which 8 implanted with pcvsdos, 7 with commercial occluders. The canines in both groups had a good recovery, good spirits, good diet, and activity. No postprocedural paralysis, hematuria, bloody stools were observed. All canines survived to the follow-up to the end. At one week and one month after intervention, ECGs showed that all of the canines were of sinus rhythm and no arrhythmia. TTE demonstrated that, in all of the occluders, no shift, no residual shunt, and no vegetation appeared in the surface of the occluder or within the heart. There were no obvious tricuspid and aortic regurgitation, either. 3.1. Gross Examination. After one week, one month, and 3 months of the intervention, two canines in each group were sacrificed each time at those time points. The remaining three canines were ready to be breeding for three years. At day 7, the pcvsdos surface was covered by grey-white membranes completely (Figure 2), while the commercial VSDOs had no tissue by gross examination. After three months, the new type occluder group occluders implanted had less neotissue around the site, while the commercial VSDO occluder group had more neotissue blocking around.

4 BioMed Research International (a) (b) (c) (d) (e) (f) Figure 3: (a), (c), and (e) are the HE and CD34 immunohistochemical staining of the pcvsdo s surface neotissue at 1 month after implantation. These three panels prove the occluder surface has complete endothelialization. (b), (d), and (f) at 3 months show that endothelial cells were arranged more regularly. 3.2. HE Staining. Two groups of occluder surface neotissues were obtained by using a sharp blade striping, stained with HE. Micrographs showed that the surface of pcvsdo at day 7hadtheneotissuecovering,andatdays30and90the neotissue surface was covered with flat cells. Commercial occluder surface was covered with neotissue at day 30 and flat cells at day 90 (Figures 3 and 4). 3.3. Immunohistochemical Staining. The neotissues of the surfaceofpcvsdowerestainedpositivelywithcd34atdays 30 and 90, while, in neotissues of the surface of commercial occlude, CD34 staining was positive only at day 90 (Figures 3 and 4). 3.4. Scanning Electron Microscopy. Scanning electron microscopy was performed in the neotissue of the surface of the occluder. It was found that the surface tissue of the pcvsdo had connective tissue at day 7 and was completely covered by neoendothelial cells at day 30, and the endothelial cells were fusiform and arranged in neat rows at day 90. The surface of commercial occluders was covered with connective tissue at

BioMed Research International 5 (a) (b) (c) (d) (e) (f) Figure 4: (a), (c), and (e) are the HE and CD34 immunohistochemical staining of the commercial VSDO s surface neotissue at 1 month after implantation. On the occluder s surface neotissue, HE staining found no flat cells. CD34 immunohistochemical staining found no positive staining particles and scanning electron microscopy also no endothelial cells. (b), (d), and (f) at 3 months show that endothelial cells presented at the surface of neotissue. day 30 and completely covered by endothelial cells at day 90 (Figures 3 and 4). 4. Discussion This study uses pcvsdo transcatheter closure of the canine VSDmodel,threecasesofcanines deathsintheprocessof septal model establishment, which has nothing to do with the implantation of the occluder. 15 of 18 canines were successfully set up for VSD models, which closed with pcvsdos and commercial occluders. After closure, all canines survived tilltheendpointsoffollow-up.duringthefollow-up,the canines were normal, their spirits were in good condition, and their behaviors had no obvious abnormalities. They also had no hemiplegia, no gross hematuria, and their urine color and frequency were normal. Follow-up ECG at days 7 and 30 did not show any arrhythmia. In four-week time, TTE showedclearimageoftheoccluderandnoobvioustricuspid and aortic regurgitation. There were no residual shunts, no vegetationintheheartandthesurfaceoftheoccluder,and no occluder dislocation as well. All of these results suggested that this new occluder is reliable and is safe to use.

6 BioMed Research International NitinolVSDOwasimplantedintheVSDsite.Twodiscs of the occluder are folded together while squeezing the septal organization, and this leads to tissue edema. When the heart isbeating,thefrictionbetweenthebarenitinolwireand the surrounding tissue will cause damage to the myocardial and result in the inflammatory response in the early period after the closure device is implanted. Subsequently, around the occluder and tissue binding sites, the increasing of the number of fibroblasts of the new organization will increase theproliferationofneotissue.andthemoreintenseinthe inflammatory response at the early stage, the more obvious neotissue is. The neotissue will pull the surrounding normal myocardial tissue, oppress the conduction organization, and lead to the occurrence of arrhythmia [12, 13]. It is found in this study that the neotissue proliferation in the surface of occluder was significantly less than the commercial occluder. We speculate that the reason is due to the effect of the coated occluder. The coating becomes the barrier between the hard nitinol wire and the soft heart; thus this changes the contacting with hard-soft mode to soft-soft mode, thereby reducing the inflammatory response and the tissue proliferation in the surface and the surrounding of occluder. Therefore it can be predicted that postoperative arrhythmias, especially complete atrioventricular block, will less occur accordingly. After VSD occluder implanted, many patients have significant residual, and it has been reported up to 50%. The reason is partly because the occluder is too small but largely because the Dacron in the middle of VSDO is sutured between the nickel-titanium alloy wires, which make the edge of the gap left and result in residual shunt. When the high-speed blood flows through the gap, it will impact on the right disk of nitinol, leading to hemolysis. In the event of hemolysis, if not handled in a timely manner, it will result in serious complications such as renal failure. Our design of pcvsdo whose surface is covered with a layer of polyester coat can prevent the red blood cells from making the direct impact of thenitinolwireandtoavoidhemolysis[7, 8]. Fromtheobservationoftheneotissueontheoccluder surface with the gross examination, we can find that, on the surface of rough pcvsdo, the time required for the neotissue completely covered and complete endothelialization is much less when compared with smooth commercial VSDO. So we believe that the rough graft surface contacts with blood can make the endothelial cells much easier to adhere and to grow. This finding has not yet been reported in the literature. Will a rough surface directly contacting with the blood lead to an increase in the risk of thrombosis? From the results of our study, eight canines implanted with pmvsd, with intraprocedural heparin anticoagulation, and aspirin antiplatelet after surgery; none of them has thrombosis occurred in 6 months. So we think that, with formal anticoagulation, antiplatelet treatment, pcvsdo will not increase the risk of thrombosis, similar to the rough Dacron patch of VSD. 5. Conclusions The pcvsdo can be implanted by transcatheter methods on canine model for VSD closure, and the procedure method is simple, safe, and reliable. It also has a reliable effect and an excellent biocompatibility. Compared to commercial occluder, it can also make endothelialization happen significantly ahead of schedule. 6. Limitations Inretrospect,thestudywehavecarriedouthasthefollowing limitations. First, the position of the defect is not exactly in the perimembranous area. Second, the histological test is lack of analysis of local inflammatory answer. Third, the canine model could have a different behaviour compared to humans. Last, the canines had been followed up for 3 months in our study since the complete endothelialization was achieved in 3 months. However, longer follow-up periods seemtobenecessarytoexaminetheeffectofthedeviceonthe myocardium. Conflict of Interests The authors have no conflict of interests. Authors Contribution Drs.YongZhouandFengChencontributedequallytothis study. References [1] Y. Qin, J. Chen, X. Zhao et al., Transcatheter closure of perimembranous ventricular septal defect using a modified doubledisk occluder, American Cardiology, vol. 101, no. 12, pp.1781 1786,2008. [2] H. Wu, Y. Qin, X. Zhao et al., Transcatheter closure of multihole perimembranous VSD with aneurysm: 3-year follow-up study, Clinical Research in Cardiology, vol. 98, no. 9, pp. 563 569, 2009. [3] M.Gu,X.You,X.Zhao,X.Zheng,andY.Qin, Transcatheter device closure of intracristal ventricular septal defects, American Cardiology, vol. 107, no. 1, pp. 110 113, 2011. [4] M.Carminati,G.Butera,M.Chessaetal., Transcatheterclosure of congenital ventricular septal defects: results of the European Registry, European Heart Journal,vol.28,no.19,pp.2361 2368, 2007. [5] G. Butera, M. Carminati, M. Chessa et al., Transcatheter closure of perimembranous ventricular septal defects. Early and long-term results, the American College of Cardiology,vol.50,no.12,pp.1189 1195,2007. [6] R. Holzer, J. De Giovanni, K. P. Walsh et al., Transcatheter closure of perimembranous ventricular septal defects using the Amplatzer membranous VSD occluder: immediate and midterm results of an international registry, Catheterization and Cardiovascular Interventions, vol. 68, no. 4, pp. 620 628, 2006. [7] S. Mulvaney and V. Grech, Hemolysis after Amplatzer device closure of ventricular septal defect, Images in Paediatric Cardiology, vol. 9, pp. 4 5, 2007. [8] Z. M. Hijazi, F. Hakim, A. A. Haweleh et al., Catheter closure of perimembranous ventricular septal defects using the new

BioMed Research International 7 amplatzer membranous VSD occluder: initial clinical experience, Catheterization and Cardiovascular Interventions,vol.56, no. 4, pp. 508 515, 2002. [9] R.J.Pinto,B.V.Dalvi,andS.Sharma, Transcatheterclosure of perimembranous ventricular septal defects using amplatzer asymmetric ventricular septal defect occluder: preliminary experience with 18-month follow up, Catheterization and Cardiovascular Interventions,vol.68,no.1,pp.145 152,2006. [10] M. Carminati, G. Butera, M. Chessa, M. Drago, D. Negura, and L. Piazza, Transcatheter closure of congenital ventricular septal defect with Amplatzer septal occluders, The American Journal of Cardiology,vol.96,no.12,pp.52 58,2005. [11] Z. Ding, Y. Qin, J. Hu et al., A new pan-nitinol occluder for transcatheter closure of ventricular septal defects in a canine model, Interventional Cardiology, vol. 22, no. 2, pp. 191 198, 2009. [12] R. Foth, T. Quentin, I. Michel-Behnke et al., Immunohistochemical characterization of neotissues and tissue reactions to septal defect-occlusion devices, Circulation, vol.2,no.2,pp. 90 96, 2009. [13] R. Holzer and Z. M. Hijazi, Interventional approach to congenital heart disease, Current Opinion in Cardiology, vol. 19,no. 2, pp.84 90,2004.

MEDIATORS of INFLAMMATION The Scientific World Journal Gastroenterology Research and Practice Diabetes Research International Endocrinology Immunology Research Disease Markers Submit your manuscripts at BioMed Research International PPAR Research Obesity Ophthalmology Evidence-Based Complementary and Alternative Medicine Stem Cells International Oncology Parkinson s Disease Computational and Mathematical Methods in Medicine AIDS Behavioural Neurology Research and Treatment Oxidative Medicine and Cellular Longevity