GSI AUDIOSTAR PRO CLINICAL TWO-CHANNEL AUDIOMETER

Similar documents
TWO CHANNEL CLINICAL AUDIOMETER AUDIOSTAR PRO

GRASON-STADLER HEARING ASSESSMENT SYSTEMS

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard

GSI 61 CLINICAL TWO-CHANNEL AUDIOMETER

AD226 Diagnostic Audiometer

The true clinical hybrid audiometer. Interacoustics. Clinical Audiometer AC40. Stand alone & PC-based audiometry in one box.

myaudiometer. It s familiar, and it s so much

Diagnostic Audiometer

The true clinical hybrid audiometer Stand alone & PC-based audiometry in one box. Interacoustics. Clinical Audiometer AC40.

AUDIOLAB Two channel clinical audiometer. Tonal Audiometry Vocal Audiometry MASKING SISI ABLB Decay Test BEKESY

AUDIOMETERS AUDIXI 10

AA-M1C1. Audiometer. Space saving is achieved with a width of about 350 mm. Audiogram can be printed by built-in printer

AC40. The true clinical. hybrid

AC40 Technical Specificatons Page 1. Technical Specifications AC40. Clinical Audiometer

AC40 Technical Specificatons. Technical Specifications AC40. Clinical Audiometer D F 2017/11

AC40. Clinical Audiometer. Save time Focus on results. Interacoustics. l e a d i n g d i a g n o s t i c s o l u t i o n s

GSI AMTAS AUTOMATED AUDIOMETRY. Setting The Clinical Standard

Oscilla - excellence since 1960

Equinox 2.0 PC-based audiometer. Not just an audiometer - A full counseling and reporting solution

Equinox 2.0. PC-based audiometer. Time saving solutions. Interacoustics. leading diagnostic solutions

The true hybrid Stand alone & PC-based audiometry in one box

AD629 The true hybrid

EPIC-PLUS System for auditory evoked potentials and neuro-otology. PEA - VEMPs ASSR - E-ABR FACIAL NERVE

AT235/AT235h Middle Ear Analyzers. Diagnostic & clinical tympanometry with basic audiometry.

Operating Instructions MA 52

The true hybrid Stand alone & PC-based audiometry in one box

UNITY 2. a state-of-the-art audiological integrated diagnostic and fitting system

AMBCO AUDIOMETER

Audiology Equipment p r o d u c t s c AtA l o g u E

The true hybrid Stand alone & PC-based audiometry in one box

GSI AUDIOscreener OAE AND ABR HEARING SCREENING

Diagnostic Impedance & Audiometry in one solution

Affinity 2.0 integrated fitting solution. Audiometry, REM, HIT, and Visible Speech Mapping

AA222 / AA220. Audio Traveller. Save time on routine. Focus on results. Interacoustics. leading diagnostic solutions

AMBCO 1000+P AUDIOMETER

Experience the power of integration

FONIX FA-12 Hearing Evaluator Digital Audiometer

Operation Manual MA 41

INTRODUCTION TO PURE (AUDIOMETER & TESTING ENVIRONMENT) TONE AUDIOMETERY. By Mrs. Wedad Alhudaib with many thanks to Mrs.

SOFTWARE INSTRUCTION MANUAL

ERO SCAN. OAE Test System. Screener. Diagnostic. with 4 frequency DPOAE testing Protocols

by Maico Diagnostics

Neuro-Audio Version 2010

Operating Instructions MA 25

General about Calibration and Service on Audiometers and Impedance Instruments

Communications Accessibility with Avaya IP Office

Operating Instructions MA 41

Organisation Internationale de Métrologie Légale

ER75 Electro-Acoustic Ear Simulator. Operating Manual

OAE Test System. Screener PLUS. Diagnostic PLUS. with 4 frequency DPOAE testing Protocols

OIML R 122 Annex C RECOMMENDATION. Edition 1999 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

The Eclipse High quality evoked potentials at your command. AEP, ASSR, & OAE testing on one dedicated platform

Contents. QuickSIN.. 15 Hearing Loss Simulator Master Hearing Aid Printing Limited Warranty.. 20 #0086.

ATMOS 360 diagnostics. Complete solution.

MA 25 Operating Manual

Note: This document describes normal operational functionality. It does not include maintenance and troubleshooting procedures.

VPAT Summary. VPAT Details. Section Telecommunications Products - Detail. Date: October 8, 2014 Name of Product: BladeCenter HS23

ERO SCAN. Otoacoustic Emission Testing

OtoRead Portable OAE. More Time for Care. Optimized for Accuracy and Ease of use

FONIX FP35. Ease and Accuracy with the FP35 Touch Hearing Aid Analyzer! Visible Speech

ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE VEMP ECochG MLR P300

A full product range for your every need. World leading diagnostic solutions

The future of fitting

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device.

Two Modified IEC Ear Simulators for Extended Dynamic Range

Handheld OAE-Tympanometry Combination System

iclicker2 Student Remote Voluntary Product Accessibility Template (VPAT)

User Guide. For Jacoti Hearing Center Pro Version 1.0. Manufacture Year 2017

Additional Information. PC-based Audiometer Equinox 2

TRAINING MANUAL. AVANT The Perfect Screening Audiometer AIR+

Hearing Solutions Catalog Winter Supplement January 2009

AT235 Middle Ear Analyzer. Diagnostic & clinical tympanometry with basic audiometry

Summary Table Voluntary Product Accessibility Template. Supporting Features Not Applicable Not Applicable. Supports with Exceptions.

Voluntary Product Accessibility Template (VPAT)

ISO INTERNATIONAL STANDARD

Accessibility Standards Mitel MiVoice 8528 and 8568 Digital Business Telephones

L G Davison*, BSc C Barlow, PhD, MIOA M Ashmore, RHAD, MIOA R Weinstein, RHAD Southampton Solent University Faculty of Maritime and Technology

Avaya Model 9611G H.323 Deskphone

Product Model #: Digital Portable Radio XTS 5000 (Std / Rugged / Secure / Type )

SUMMARY TABLE VOLUNTARY PRODUCT ACCESSIBILITY TEMPLATE

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

This Page Intentionally Left Blank

Avaya IP Office 10.1 Telecommunication Functions

The second breakthrough in clinical audiometry

Reliable, flexible & precise

General Catalogue. Product Line for Hearing Screening & Diagnostics

Table of Contents Morning Set-up (GSI equipment, only)... 2 Opening AudBase... 3 Choosing a patient... 3 Performing Pure-Tone Air & Bone

AMBCO 2500 AUDIOMETER SYSTEM WITH FIVE YEAR WARRANTY

QUICK START GUIDE SENTIERO OAE, TYMP AND AUDIOMETRY SCREENING ( and )

Personal Listening Solutions. Featuring... Digisystem.

VALIDITY OF DIAGNOSTIC COMPUTER-BASED AIR AND FOREHEAD BONE CONDUCTION AUDIOMETRY

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

Supplementary Online Content

iclicker+ Student Remote Voluntary Product Accessibility Template (VPAT)

SUMMARY TABLE VOLUNTARY PRODUCT ACCESSIBILITY TEMPLATE

This document presents the reader with instructions on using AudBase in the UCSF environment. AudBase Guidebook. Application How-To.

Transcription:

GSI AUDIOSTAR PRO CLINICAL TWO-CHANNEL AUDIOMETER Setting The Clinical Standard

GSI AUDIOSTAR PRO CLINICAL TWO-CHANNEL AUDIOMETER Tradition of Excellence The GSI AudioStar Pro continues the tradition of excellence in clinical audiometry by maintaining the Grason-Stadler legacy of fast, efficient, and familiar navigation. The one-button, one-function front panel of the AudioStar Pro is recognized worldwide as the Gold Standard of user-friendly design, allowing audiologists to test with confidence. AudioStar Pro has every desired feature such as: an extra large display that reduces eye strain, an ergonomic housing that maximizes hand and wrist comfort, and light pipes around selected test buttons allowing concentrated focus on the patient. Stand-Alone/ PC Enabled Audiologists appreciate the flexibility of a stand-alone audiometer that offers seamless data transfer to a computer. In the event of a network failure or computer lock-up, you will not lose patient data or the ability to test. The stand-alone configuration is optimized with direct connection to a wireless keyboard and mouse making it fast and easy to enter patient demographics, report comments, and expedite test administration. In addition, direct connection to a printer and the integrated print button make it possible to print a complete report for immediate review with the patient or physician. EMR/EHR Ready User login and password controls provide security for patient data in compliance with HIPAA. Complete audiometric results can be transferred to software such as GSI Suite and Noah 4, or integrated with your facility s EMR/EHR system. EMR/EHR Compatible GSI Suite GSI Suite captures, saves and shares patient information improving reporting to support the needs of the contemporary clinic. GSI Suite is now available as a Noah module for seamless integration to hearing aid fittings. GSI Suite Features Powerful custom report designer Select from a variety of provided report templates Test results in EMR/EHR compatible format (PDF) Retrieve test results for review Print reports from PC compliant printers Network results from multiple instruments by combining GSI Suite with OtoAccess or Noah 4 Setting The Clinical Standard

Technical Features Custom Configuration Configurable tests and preferences to improve workflow and optimize speed of testing. Panel Navigation Gold standard ergonomic design with familiar one-button, one-function front panel navigation. Special Tests Pre-configured special tests such as QuickSIN, BKB-SIN, TEN (HL), ABLB, SISI and Tone Decay addresses the research trends in hearing evaluation. Assistant Monitor Allows direct communication between operator and assistant eliminating the need for an external intercom system. Word Lists Integrated internal digital word lists provide effortless access to commonly used word lists providing consistent and reliable recorded speech testing. Two-Channel Control Audiologist can mix signals and route them to either one or both ears making hearing evaluations easier than ever.

Direct Print Expedite the data entry and test administration. Use the external keyboard and mouse to enter patient demographics, session comments and print a complete report to a connected printer. Data Transfer Electronic data is transferred with a single button press. VRA Controls The built-in VRA controls allow for fast and simple activation of VRA systems. On-Board Navigation Access integrated word lists and menu selections using the front panel navigation.

audiostarpro Fast Features such as speech auto play, auto advance and auto frequency selection allow the examiner to improve productivity and patient flow. Standard features, such as the headset microphone, allows the operator to communicate directly with patients while the built-in monitor speaker makes it easy for third parties to participate in the hearing evaluations. Sound field options are available from the standard 90 db HL output to the high performance speakers with 96 db HL - both without any external amplification needed. The maximum output of 102 db HL is available with an external amplifier - achieving the highest output in the industry. Four speaker calibration is available for advanced sound field testing. One button, one function incorporated with a large display maintains the GSI legacy of fast and efficient navigation. Familiar The AudioStar Pro maintains the user friendly interface that has defined GSI since 1949. Audiologists will feel an immediate connection to both the display and intuitive control panel while being surrounded by new innovative features. This revolutionary audiometer maintains maximum flexibility in a two-channel audiometer allowing full control in testing procedures for every patient population. Customizable Test Type Buttons allow access to protocols that are customized to facility preferences. The AudioStar Pro uses a Configuration Application software to customize preferences for efficient and consistent testing. Auto Play, Auto Score, and Word List "Favorites" ensure seamless integration of the 50+ commonly used word lists included with every AudioStar Pro. The integrated Special Tests including Quick-SIN, BKB-SIN and TEN (HL) address research trends in hearing evaluation. The AudioStar Pro combined with GSI Suite, brings a new level of customized reporting options that addresses the requirements of both the facility and referral sources. Efficient Additional features integrated into the AudioStar Pro makes testing every patient even more seamless by configuring pure tone and speech preferences. The built-in auxillary intercom, active microphone during tone presentation as well as remote testing capabilities provide a multitude of options for testing difficult to test patients. The integrated intelligent functionality of activating sound field speakers during hearing aid or cochlear implant testing improves both efficiency and accuracy. Compatible The AudioStar Pro addresses the challenges of data management such as patient security and HIPAA compliance through our electronic record solutions: (E-Record Solutions). These solutions safely and easily integrate audiometric data into every facility s data management system from VA, ENT, Private Practice, Hearing Aid, Cochlear Implant and Pediatric facilities. For more information, go to www.audiostarpro.com

GSI AudioStar Pro CLINICAL TWO-CHANNEL AUDIOMETER Product Specifications Dimensions and Weight W x D x H: 20.1 inches x 14.6 inches x 13.2 inches (LCD raised) 51.0 cm x 37.0 cm x 33.5 cm Height with LCD lowered 5.5 inches (14.0 cm) Weight: 17 lb (7.7 kg) Shipping Weight: 27 lb (12.25 kg) Power Consumption: 90 Watts Channels Two Independent Channels Pure Tone Channels 1 and 2 Frequency Range: Air Conduction: 125 Hz to 12,000*** Hz High Frequency:* 8,000 Hz to 20,000 Hz (8 khz, 9 khz, 10 khz, 11.2 khz, 12.5 khz, 14 khz, 16 khz, 18 khz*** and 20 khz***) Full Frequency Range:* 125 Hz to 20,000 Hz Bone Conduction: 250 Hz to 8,000 Hz Sound Field:* 125 Hz to 8,000 Hz Paired Inserts:* 125 Hz to 8,000 Hz Frequency Accuracy: ±1% Total Harmonic Distortion: < 2% (earphones and paired insert phones*) < 5% (bone vibrator) Intensity Range:** Air Conduction (TDH 50P): -10 db HL to 120 db HL High Frequency:* -20 db HL to 100 db HL (with Sennheiser HDA 200 Phones) Bone Conduction Mastoid: -10 db HL to 75 db HL Forehead: -10 db HL to 65 db HL Sound Field:* -10 db HL to 90 db HL (basic speakers) -10 db HL to 96 db HL (high performance speakers) -10 db HL to 102 db HL (high performance speakers and external booster amplifier) Paired Inserts:* -10 db HL to 110 db HL Masking Intensity Range (Calibrated in effective masking) Narrow Band Noise: Maximum db HL is 15 db below tone White Noise: Maximum db HL is 30 db below tone Signal Format: Steady: Tone continuously present. Pulsed: Tone pulsed 200 msec ON, 200 msec OFF FM: Modulation Rate: 5 Hz Modulation Depth: +/- 5% Pulsed/FM: Pulsed and Modulated Pediatric Noise Pediatric Noise Pulsed Speech Channels 1 and 2 Microphone: For live voice testing and communications INT/EXT A & INT/EXT B: Can be utilized for internal wave files or recorded speech material from an external digital device Intensity Range: Air Conduction: -10 db HL to 100 db HL for TDH 50P (Linear Type 4) Bone Conduction Mastoid: -10 db HL to 55 db HL Forehead: -10 db HL to 35 db HL Sound Field:* -10 db HL to 80 db HL Paired Inserts:* -10 db HL to 95 db HL Masking Intensity Range: Speech Noise: Air Conduction: -10 db HL to 95 db HL (TDH 50P) Bone Conduction: -10 db HL to 50 db HL (mastoid) -10 db HL to 35 db HL (forehead) Sound Field: -10 db HL to 80 db HL White Noise: Air Conduction: -10 db HL to 95 db HL (TDH 50P) Bone Conduction: -10 db HL to 50 db HL (mastoid) -10 db HL to 35 db HL (forehead) Sound Field: -10 db HL to 80 db HL Special Tests ABLB or Fowler: Tone alternating between Channel 1 and Channel 2: Channel 1 is 400 msec ON, 400 msec OFF followed by Channel 2, 400 msec ON, 400 msec OFF. SISI: An intensity increment is added to a tone in the selected channel for 200 msec, every 5 seconds. The HL increments are in 1, 2 or 5 db. High Frequency:* Pure tone testing in the frequency range of 8,000 Hz to 20,000 Hz using circum-aural headphones. TEN: TEN masking noise will be presented to the test ear. Pure tone stimuli between 500 Hz and 4000 Hz may be used at 1, 2, or 5 db increments to obtain TEN thresholds. QuickSIN: Six (6) sentences with five (5) key words per sentence are presented in four-talker babble noise. The sentences are presented at pre-recorded signal-to-noise ratios. The SNR s used are 25, 20, 15, 10, 5, and 0. BKB-SIN: Contains 18 List Paris. The sentences are presented at prerecorded signal-to-noise ratios that decrease in 3-dB steps. Each list in the pair is individually scored, and the results of the two lists are averages to obtain the List Pair score. Results are compared to normative data to obtain the SNR Loss. PC Enabled/Stand Alone Transfer data to connected PC with an E-Record Solution Software Print complete report directly to a compatible USB printer Special Tests (user defined) MLB Lombard test Pure Tone Stenger Speech Stenger SAL Doerfler - Stewart Test Communications and Monitoring Talk Forward: Permits the tester to speak through the examiner microphone into the selected transducer. Talk Back: Allows the examiner to listen to comments from the patient in the testing booth. Monitor: The monitor headset or monitor speaker built into the instrument housing may be used by the examiner to listen to Channel 1, Channel 2, Aux intercom, and/or Talk Back signals. Aux Intercom: The built-in Auxiliary Intercom and assistant headset allows the examiner to speak directly to an Assistant and allows the assistant to hear what is being presented to the patient. On-Board VRA Control: The built-in VRA controls facilitate fast and simple activation of VRA systems. Optional Accessories Wireless keyboard and mouse Gooseneck microphone Environmental Requirements Temperature: +15ºC to 40ºC (59 to 104ºF) Relative Humidity: 5% to 90% (non-condensing) Ambient Pressure Range: 98 kpa to 104 kpa Background Sound Level: <35 db(a) Frequency of Use: Once a year to multiple times per day Storage Temperature: -20ºC to + 60ºC (-4ºF to 140ºF) Quality System Manufactured, designed, developed and marketed under ISO 13485 certified quality systems Compliance/Regulatory Standards Designed, tested and manufactured to meet the following domestic (USA), Canadian, European and International Standards: ANSI S3.6, ANSI S3.43, IEC 60645-1, IEC 60645-2, ISO 389 UL 60601-1 American Standards for Medical Electrical Equipment IEC/EN 60601-1 International Standards for Medical Electrical Equipment CSA C22.2 # 601-1-M90 Medical Device Directive (MDD) to comply with EC Directive 93/42/EEC * Optional configuration ** The maximum HL values are applicable to the middle frequencies only *** Optional configuration 501C-1 Rev. C www.grason-stadler.com Grason-Stadler, 7625 Golden Triangle Drive, Suite F, Eden Prairie MN 55344 800-700-2282 952-278-4402 fax 952-278-4401 e-mail info@grason-stadler.com