MRI for Patients with MRI-Conditional Pacing System: Radiographers Role. Lawrance Yip DM, DR, QMH

Similar documents
STANDARD OPERATING PROCEDURE (SOP)

MRI SureScan pacemakers & ICDs what you need to know

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500)

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500)

Algovita. MRI Procedure Guidelines. Spinal Cord Stimulation System. 201x

Safety Issue of Static Magnetic Field (1)

Read this manual before performing an MRI scan on a patient implanted with an Algovita Spinal Cord Stimulation System.

MRI and CIEDs. Disclosures

Q & A: How to Safely Scan Patients with a SureScan MRI Pacemaker

Micra MC1VR01. MRI procedural information for Micra Model MC1VR01 MR Conditional single chamber transcatheter pacing device (VVIR)

MRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System

MRI Guidelines for the Axonics Sacral Neuromodulation System

MRI imaging for patients with cardiac implantable electronic devices (CIEDs)

Advisa MRI and Ensura MRI SureScan pacing systems

VNS Therapy System Physician s Manual

Cardiac Rhythm Therapy // Advanced Features // ProMRI. ProMRI. Checklist and Quick Reference Guide

MRI GUIDELINES FOR INSPIRE THERAPY

MRI Exams in Patients with Non MR Conditional Pacemakers and with MR Conditional Pacemakers

Initial Experience with a Radiologist-Managed MR Imaging Cardiac Pacemaker Program in an Academic-Affiliated Community Hospital

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System

MRI conditional devices. A luxury or a real clinical need? Sophie Mavrogeni, MD, FESC Onassis Cardiac Surgery Center, Athens, Greece

Cardiac Rhythm Management // Manual // ProMRI. ProMRI. MR conditional device systems

ImageReady MRI Head Only Guidelines for Spectra WaveWriter Spinal Cord Stimulator System

MRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System

MRI GUIDELINES FOR INSPIRE THERAPY

ImageReady MRI Full Body Guidelines for Precision Montage MRI Spinal Cord Stimulator System

*smith&nephew. MRI Safety Information & Parameters for Smith & Nephew Orthopaedics AG. Knee Implants

MRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System

Version überholt. Nicht verwenden. Version obsolète. Ne pas utiliser. Versione obsoleta. Non utilizzare. Verouderde versie. Niet gebruiken.

Peri-operative management of pacemakers and implantable cardiac defibrillators

*smith&nephew. MRI Safety Information & Parameters for Smith & Nephew Orthopaedics AG. Shoulder Implants

EXAMPLE PROTOCOL FOR PATIENT SCANNING PROCESS

Lead Management for MRI

Call Medtronic at 1 (800) to verify the patient s current implanted system

Warning: Patients should not be exposed to MRI environments until the surgical site following pump implantation is fully healed.

2014 AAPM 56 th Annual Meeting

MRI Procedure Information. For St. Jude Medical MR Conditional Neurostimulation Systems. Clinician's Manual

MRI Safety Information for the HiRes Ultra 3D Cochlear Implant

Low-Profile Wrist Fixator. For stabilization of fractures of the distal radius.

MRI in Patients with Pacemakers and Defibrillators. Paul A. Friedman, MD Win K Shen, MD Robert E. Watson, Jr. MD, Phd October 2016

*smith&nephew. MRI Safety Information & Parameters for Smith & Nephew Orthopaedics AG. Hip Implants

MRI Procedure Information. For St. Jude Medical MR Conditional Neurostimulation Systems. Clinician's Manual

IMAGEREADY MR CONDITIONAL PACING SYSTEM

CARDIAC DEVICE MR-CONDITIONAL PRODUCT SUMMARY CHART

Flowchart for ICD patients undergoing Surgery or procedures involving diathermy/magnetic fields

Devices and EP- Safety in MRI

The heart's "natural" pacemaker is called the sinoatrial (SA) node or sinus node.

Managing Metallic Artifacts in MRI

REBEL. Platinum Chromium Coronary Stent System. Patient Information Guide

Procedure for exceptional magnetic resonance scanning in patients with standard (non-mr-conditional) pacemakers

MRI SURESCAN SYSTEMS. Patient Scanning Process PATIENT PRESCREENING. SureScan Pacing, Defibrillation, and CRT-D Systems Verification

PATIENT CARE AND MRI SAFETY Module 7

Department of Radiology

External Distal Radius Fixator. Supplement to the 8 mm rod fixator system

MRI guidelines for Medtronic neurostimulation systems for chronic pain

Cochlear Implants. Medical Procedures. for MED EL CI Systems. AW33290_5.0 (English US)

Yes, out of sight out of mind.

GUIDELINE 2-G-004 (formerly APPENDIX 3) HSREB (March 2005) Page 1

Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing. D. J. McMahon cewood rev

SJM MRI ACTIVATOR HANDHELD DEVICE WORKFLOW Model: EX4000. SJM-EDTR Item approved for U.S. use only.

Model 5392 EPG Temporary Pacer

MRI Guidelines for VNS Therapy

ENABLE MRI CLINICAL STUDY SUMMARY

How to set up a device clinic for heart failure patients Dr C Sridevi

NORTH OF ENGLAND CARDIOVASCULAR NETWORK (NECVN)

Building physician referrals and improve patient care for an aging population with

EnTrust D154VRC Single Chamber ICD 35J delivered 8 seconds BOL, 11.8 seconds ERI 10.7 years**** 35cc, 68g Programmable Active Can

MRI Checklist for MED EL CI and ABI models

Pacing Lead Implant Testing. Document Identifier

Cochlear Implants. Medical Procedures. for MED EL Implant Systems. AW33290_2.0 (English US)

Electrodes (for TransAeris System)

Imaging Patient Education. Magnetic Resonance Imaging (MRI)

Perioperative Management of Cardiac Implantable Devices

Pediatric pacemakers & ICDs:

8/2/2017. Acknowledgement. Disclaimer. How to manage radiotherapy patients with CIED from initial consult to treatment: TG203 recommendations

Memo on The Safety of MRI Scanning of Coronary Artery Stents

Biologic Effects of Diagnostic Imaging Modalities

Figure 2. Normal ECG tracing. Table 1.

Children's (Pediatric) MRI for Appendicitis

Cardiovascular magnetic resonance with an MR compatible pacemaker

PERIOPERATIVE MANAGEMENT: CARDIAC PACEMAKERS AND DEFIBRILLATORS

Magnetic Resonance Imaging (MRI) - Body

Module 1: Fundamentals of Patient Monitoring. Contents. Introduction. Why is monitoring in MR different? Exercise 1_1

Newer pacemakers also can monitor your blood temperature, breathing, and other factors and adjust your heart rate to changes in your activity.

WallFlex Biliary RX Partially Covered Stent System Prescriptive Information

TMS: Full Board or Expedited?

The safe and accurate measurement of liver iron concentration. Information for Patients

NEED A DEFIBRILLATOR? NOW YOU HAVE OPTIONS.

Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing

Safety of MRI at 1.5 Tesla in Patients with Implanted Sacral Nerve Neurostimulator

Pacing troubleshooting. NASPE training Lancashire & South Cumbria Cardiac Network

Protocol. This trial protocol has been provided by the authors to give readers additional information about their work.

Medium External Fixator Humeral Shaft Frame. Modular frame for upper extremity use.

856 Unintentional Deactivation of ICDs Mayo Clin Proc, August 2002, Vol 77 Figure 1. Case 3. Printout from Guidant programmer (Guidant Corp, St Paul,

MRI Information for Medtronic Spinal and Biologics Devices

A patient s step by step guide to Magnetic Resonance Imaging

9/5/17. Anesthetic considerations for patients with implanted devices for treating chronic pain and more. Objectives:

Cardiac Resynchronisation Therapy Defibrillator (CRT-D)

MRI Patient Screening and History

Revision A Date:

Transcription:

MRI for Patients with MRI-Conditional Pacing System: Radiographers Role Lawrance Yip DM, DR, QMH

MRI & Pacemaker MRI is a crucial and growing imaging modality Plays an important role in clinical management Essential for acute clinical conditions e.g. acute cord compression, acute ischemic stroke etc. Contra-indications for MRI Conventional (MRI-unsafe) pacemaker Intra-orbital metallic foreign bodies Other MRI-unsafe cardiovascular implantable electronic device and bio-medical implants

MRI & Pacemaker Potential interactions between pacemaker and MRI environment Pulse generator Unpredictable pacing mode Premature battery Pacing wire Ventricular fibrillation Pacing inhibition Deliver inappropriate shocks failure Myocardium / pacing wire interface Lead tip heating pacing threshold

MRI & Pacemaker Some centres in Europe & North America develop protocols of performing MRI for patients with conventional cardiac pacemaker Clinical, experimental & pacemaker expertise on site Certain risk remains Increase in pacing threshold MRI-related ectopy Temporary communication failure with pacemaker FDA and American Heart Association do not support MRI for patients with conventional cardiac pacemaker

MRI-Conditional Pacing System MRI safety terminology by American Society for Testing and Materials (ASTM) MRI Safe Pose no hazard in all MRI environments Non-ferromagnetic items MRI Conditional Pose no hazard in specified MRI environment with specified conditions of use MRI Unsafe Pose hazard in all MRI environments

MRI-Conditional Pacing system Specific features of MRI-conditional pacing system Reduction in ferromagnetic content of pulse generator Use of a Hall switch instead of reed switch Modification of pacing leads to reduce lead tip heating Shielding of the circuitry to minimize electro-magnetic interference Protection of internal power supply

MRI-Conditional Pacing System Adjustment of MRI protocol and procedure to minimize the chances of interaction Limited static magnetic field strength (1.5T) Limited gradient slew rate ( 200T/m/s) Limited radiofrequency power deposition (Whole body SAR 2W/kg)

MRI-Conditional Pacing System Manufacturers M B J MRI Scanner 1.5T cylindrical bore MRI system 1.5T cylindrical bore MRI system 1.5T cylindrical bore MRI system Average SAR (head) 3.2W/kg 3.2W/kg 3.2W/kg Average SAR (whole body) 2W/kg 2W/kg 4W/kg Maximum Slew Rate 200T/m/s 200T/m/s 200T/m/s Scanner mode Normal operating mode Accumulated imaging time < 30mins Patient position Supine Supine Supine Normal or first level operating mode Iso-center of RF coil No restriction Yes (for some models) Implant site R/L pectoral > 6 weeks Chest area > 6 weeks No restriction R/L pectoral >6 weeks

Guidelines on MRI for Patients with MRI-conditional Pacing System MRI request for patients with MRI-conditional pacing system Consult duty Radiologist for Indication of MRI Exam Risk / benefit analysis No MRI exam indicated for the patient? Yes Reconfirm the preconditions of pacing system is fulfilled before MRI exam MRI Unit DR, QMH Preconditions of pacing system fulfilled? Yes Arrange Cardiologist / technical personnel of MRI-conditional pacing system on site during MRI exam for programming of pacing system No Alternative imaging exam Ensure operating mode and technical parameters of MRI system are complied with the related safety recommendations of MRI-conditional pacing system Exam completed

Pre-Scan Checklist Ensure the MRI examination is clinically indicated Consult patient records to verify the model of the pacing system is MRI-conditional

Pre-Scan Checklist Ensure all pre-conditions required for MRI examination are fulfilled Patient without other MRI contra-indications e.g. other biomedical implants, abandoned leads etc. Obtain written informed consent from the patient

Pre-Scan Checklist Cardiologist shall be on site to check the parameters of cardiac pacing system Battery level Pacing threshold Lead impedance Cardiologist programs the pacemaker to MRI mode or Scanning mode immediate before MRI examination Patient ready for MRI examination

Checklist During MRI Exam. Maintain voice & visual contact with patient Emergency call bell / In-bore intercom system / CCTV Patient may feel warmth and gentle tugging sensation near the pacemaker Monitor the patient s hemodynamic functions Pulse oximetry Non-invasive blood pressure ECG Keep an external defibrillator and the emergency trolley available during MRI examination

Checklist During MRI Exam.

Checklist During MRI Exam. Ensure operating conditions of the MRI system are fully complied with safety recommendations Appropriate operating mode of the system Normal operating mode None of the system outputs may cause physiological stress to patients First level controlled operating mode One or more system outputs may cause physiological stress to patients and needs to be controlled by medical supervision Second level controlled operating mode One or more system outputs may produce significant risk for patient and explicit ethical approval is required

Checklist During MRI Exam. Normal operating mode is recommended for MRI examination of patient with MRI-conditional pacing system Restrict maximum gradient slew rate and Specific Absorption Rate (SAR) of the MRI system below the safety limits

After Care Cardiologist resumes the normal settings of pacemaker immediate after MRI examination Report of pacemaker programming shall be documented

Statistics of MRI of Patients with MRI-conditional Pacing System 2010 2013 (Total 34 MRI examinations) No adverse effect was reported in all patients 16 16 14 12 10 10 8 6 6 4 2 2 0 2010 2011 2012 2013 MRI Unit, DR, QMH

Statistics of MRI of Patients with MRI-conditional Pacing System 2010 2013 (Total 34 examinations) Brain Orbits 1 7 3 3 1 19 IAM Pituitary Gland Cervical Spine Abdomen MRI Unit, DR, QMH

Conclusion MRI-conditional pacing system is developed to allow MRI examination to be performed under specific prerequisites and technical conditions Radiographer is the most important gate-keeper of MRI safety to ensure strict adherence of the related safety guidelines so that the MRI procedures can be applied to the corresponding patients without adverse effect and benefit clinical management